Bulletin 800MR/800MB Push Buttons

Size: px
Start display at page:

Download "Bulletin 800MR/800MB Push Buttons"

Transcription

1 ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Square backlit operators UL Listed File: E14840, E10314 Guide: NKCR, NIV CSA Certified: LR1234, LR11924 IEC Compliance, IEC 529 ul. 800M ul. 800MR - Momentary Contact Push uttons uild a Catalog Number Momentary Contact Push utton Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-A1 Extended Head Unit 800MR-2A Mushroom Head Unit 800MR-D2

2 Contact Type utton Color Flush Head Extended Head Mushroom Head 1 N.. Green 800MR-A1D1 800MR-1D1 800MR-D1D1 lack 800MR-A2D1 800MR-2D1 800MR-D2D1 Red 800MR-A6D1 800MR-6D1 800MR-D6D1 1 Green 800MR-A1D2 800MR-1D2 800MR-D1D2 lack 800MR-A2D2 800MR-2D2 800MR-D2D2 Red 800MR-A6D2 800MR-6D2 800MR-D6D2 1 N Green 800MR-A1A 800MR-1A 800MR-D1A lack 800MR-A2A 800MR-2A 800MR-D2A Red 800MR-A6A 800MR-6A 800MR-D6A 2 N Green 800MR-A1 800MR-1 800MR-D1 lack 800MR-A2 800MR-2 800MR-D2 Red 800MR-A6 800MR-6 800MR-D6 800MR A 1 A a b c d a b c d perator Type utton Color Standard Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description A Flush head 1 Green lank No contacts lank Stab terminals Extended head 2 lack A 1 N K Large screw D Mushroom head 3 range A2 2 N.. 4 Grey A3 1 N..E.M. - 1 L.. 5 White A4 2 6 Red A7 1 L lue 2 N Yellow D1 1 N.. D2 1 Guards must be ordered separately. Logic Reed and small screw blocks can be ordered separately. Momentary Contact Push utton Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-QA24GA Extended Head Unit 800MR-P16RA Mushroom Head Unit 800MR-QM24RA

3 Contact Type Power Module Type Supply Voltage Lamp Type Lens Color Flush Head Extended Head Mushroom Head 1 N Full Voltage 24V AC/DC Incandescent Red 800MR-QA24RA 800MR-Q24RA 800MR-QM24RA Green 800MR-QA24GA 800MR-Q24GA 800MR-QM24GA Amber 800MR-QA24AA 800MR-Q24AA 800MR-QM24AA Transformer 120V AC Incandescent Red 800MR-PA16RA 800MR-P16RA 800MR-PM16RA Green 800MR-PA16GA 800MR-P16GA 800MR-PM16GA Amber 800MR-PA16AA 800MR-P16AA 800MR-PM16AA Full Voltage 12V AC/DC LED Red 800MR-QAL12RA 800MR-QL12RA 800MR-QML12RA Green 800MR-QAL12GA 800MR-QL12GA 800MR-QML12GA Amber 800MR-QAL12AA 800MR-QL12AA 800MR-QML12AA 24V AC/DC LED Red 800MR-QAL24RA 800MR-QL24RA 800MR-QML24RA Green 800MR-QAL24GA 800MR-QL24GA 800MR-QML24GA Amber 800MR-QAL24AA 800MR-QL24AA 800MR-QML24AA Transformer 120V AC LED Red 800MR-PAL16RA 800MR-PL16RA 800MR-PML16RA Green 800MR-PAL16GA 800MR-PL16GA 800MR-PML16GA Amber 800MR-PAL16AA 800MR-PL16AA 800MR-PML16AA 800MR PA L 24 R a b c d e f a b c d e f perator Illumination ptions Input Voltage Lens Color Standard Contact Cartridges Transformer Full Voltage Contact lock Termination Type Code Description Code Description Code Description Code Color Code Description Code Description PA Flush lank Standard illumination as determined by power module type 12 12V AC/DC A Amber lank No contacts lank Stab terminals P Extended L LED 24 24V AC/DC lue A 1 N K Large screw PM Mushroom V AC C Clear A2 2 N.. Full Voltage Transformer G Green A3 1 N..E.M. - 1 L.. Code Description Code Description R Red A4 2 QA Flush V AC 50/60 Hz W White A7 1 L Q Extended V AC 50/60 Hz No lens with contact blocks 2 N.. 2 QM Mushroom lank No lens without contact blocks D1 D2 1 N.. 1 LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Guards must be ordered separately. Logic Reed and small screw blocks must be ordered separately. ul. 800MR Push Pull uild a Catalog Number 2-Position Push-Pull and Push-Pull/Twist Release Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.

4 2-Position Push-Pull 800MR-F6A 2-Position Push-Pull/Twist 800MR-FT6A4 Contact Type perator Position utton Color Push-Pull Push-Pull/ Twist Release Maintained Maintained ut In No Contacts Red 800MR-F6 800MR-FT6 1 N.. Red 800MR-F6D1 800MR-FT6D1 1 Red 800MR-F6D2 800MR-FT6D2 1 N Red 800MR-F6A 800MR-FT6A 1-1 Red 800MR-F6A4 800MR-FT6A4 Note: = Closed/ = pen 3-Position Push-Pull Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. 3-Position Push-Pull 800MR-FN6A7 Contact Type perator Position utton Color Push-Pull Momentary Maintained Momentary ut Center In No Contacts Red 800MR-FN6 1 N Red 800MR-FN6A 1-1 L.. Red 800MR-FN6A7 1-1 L L.. Red 800MR-FN66 Note: = Closed/ = pen 800MR F T 6 A a b c d e f (2-Position)

5 800MR F N 6 A a b 1 c d e f (3-Position) a b b 1 c perator Type perator Function perator Function perator 2-Position 3 Position Code Description Code Description Code perator Position Code Color F Push-pull unit lank Maintained push pull lank Non-illuminated T Twist-release ut Center In N Momentary Maintained Momentary d e f utton Color Contact Cartridges Contact lock Termination Type Code Description Code Description Code Color lank No contacts lank Stab terminals 1 Green A 1 N K Large screw 2 lack A2 2 N.. 3 range A4 2 4 Grey A7 1 L White 2 N Red D1 1 N.. 7 lue D2 1 9 Yellow Note: See Table 1 for Target description. lank No cap Table 1. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. Logic Reed and small screw blocks must be ordered separately. 2-Position Push-Pull and Push-Pull/Twist Release Units, Illuminated

6 Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 2-Position Push-Pull 800MR-FQ24RA Illuminated 2-Position Push-Pull/Twist 800MR-FTP16RA Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Push-Pull/ Twist Release Maintained Maintained Contacts ut In Incandescent Full Voltage 12V AC/DC Red N MR-FQ12RA 800MR-FTQ12RA 24V AC/DC Red 800MR-FQ24RA 800MR-FTQ24RA Transformer 120V AC Red N MR-FP16RA 800MR-FTP16RA 240V AC Red 800MR-FP26RA 800MR-FTP26RA LED Full Voltage 12V AC/DC Red N MR-FQL12RA 800MR-FTQL12RA 24V AC/DC Red 800MR-FQL24RA 800MR-FTQL24RA Transformer 120V AC Red N MR-FPL16RA 800MR-FTPL16RA 240V AC Red 800MR-FPL26RA 800MR-FTPL26RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 3-Position Push-Pull Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 3-Position Push-Pull 800MR-FNQ24RA7

7 Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Momentary Maintained Momentary Contacts ut Center In Incandescent Full Voltage 12V AC/DC Red L MR-FNQ12RA7 24V AC/DC Red 800MR-FNQ24RA7 Transformer 120V AC Red L MR-FNP16RA7 240V AC Red 800MR-FNP26RA7 LED Full Voltage 12V AC/DC Red L MR-FNQL12RA7 24V AC/DC Red 800MR-FNQL24RA7 Transformer 120V AC Red L MR-FNPL16RA7 240V AC Red 800MR-FNPL26RA7 Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR F T P 16 R A a b c d e f g h (2-Position) 800MR F N P 16 R A a b 1 c d e f g h (3-Position) a b b 1 c d perator Type perator Function perator Function perator Type Illumination ptions 2-Position 3-Position Code Description Code Description Code perator Position Code Description Code Description F Push-pull unit lank Maintained P Transformer lank Incandescent lamp T Twist-release ut Ctr. In Q Full voltage L LED N Mom Main Mom Mom-Momentary Main-Maintained e f g h Voltage utton Color Contact Cartridges Contact lock Termination Type Full Voltage Code Description Code Color Code Description Code Description 12 12V AC/DC A Amber lank No contacts lank Stab terminals 24 24V AC/DC lue A 1 N K Large screw V AC C Clear A2 2 N.. Transformer G Green A4 2 Code Description R Red A7 1.L V AC 50/60 Hz W White 2 N V AC 50/60 Hz No cap D1 1 N.. D2 1 Note: See Table 1 for Target description.

8 Table 2. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Logic Reed and small screw blocks must be ordered separately. ul. 800MR - Selector Switches uild a Catalog Number 2-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-HH2LA Knob Lever perator 800MR-HK2LA Contact Type Knob Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M 800MR-HH2LA 800MR-HK2LA S M 800MR-HH4LA 800MR-HK4LA 1 N M S 800MR-HH5LA 800MR-HK5LA lack A M M 800MR-HH2 800MR-HK2 S M 800MR-HH4 800MR-HK4 Right A 2 N M S 800MR-HH5 800MR-HK5 Note: = Closed/ = pen 2-Position Cylinder Lock perator 800MR-H31

9 Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in Lock in Right Lock in oth A M M 800MR-H31LA 800MR-H32LA 800MR-H33LA S M 800MR-H42LA 1 N M S 800MR-H48LA A M M 800MR-H31 800MR-H32 800MR-H33 S M 800MR-H42 Right A 2 N M S 800MR-H48 Note: = Closed/ = pen Target tables are reversed from those shown. Key removable in locked position only. 800MR H H 2 L A a b c d e e 1 f (Selector Switch) 800MR H 31 L A a b c 1 c 2 d e e 1 f (Cylinder Lock) a b c c 1 c 2 perator Positions perator Color and Type perator Function perator Function/Locking Position Key Codes Standard Knob Standard Knob Maintained Code Key No. Master Key Code Description Code Description Code Description Code Description lank T100 (standard) 1T H 2-position selector switch No knob 2 Maintained 31 Lock in left 02 T101 1T H 2-position cylinder lock H lack 4 Spring return from left Knob Lever 5 Spring return from right 32 Lock in right 03 T102 1T 33 Lock in both 04 T106 1T Code Description Spring Return From 05 T107 1T No knob lever Code Description 07 T109 2T K lack 42 Lock in right 08 T134 2T Cylinder Lock Spring Return From Right 09 T135 2T Code Description Code Description 10 T136 2T lank Key 48 Lock in left 14 T147 2T

10 d e e 1 f Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description cam lank oth left and right lank No contacts lank Stab terminals L A 1 N K Large screw A2 2 N.. A4 2 2 N D1 1 N.. D2 1 P1 3 N.. P2 3 P3 2 N P4 2-1 N.. P5 4 N.. P6 4 P7 3 N P8 1 N Note:See Table 1 for Target arrangements Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Returned From Right Spring Returned From N.. N.. Note: = Closed/ = pen Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L. Contact cartridge position code (Table e) must be Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-JH2 Knob Lever perator 800MR-JK2

11 Contact Type Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M M 800MR-JH2LA 800MR-JH2LA S M M 800MR-JH4LA 800MR-JK4LA M M S 800MR-JH5LA 800MR-JK5LA 1 N S M S 800MR-JH9LA 800MR-JK9LA lack A M M M 800MR-JH2 800MR-JK2 S M M 800MR-JH4 800MR-JK4 Right A M M S 800MR-JH5 800MR-JK5 2 N S M S 800MR-JH9 800MR-JK9 Note: = Closed/ = pen Cylinder Lock perator 800MR-J44 Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in All Lock in Center Lock in Right A M M M 800MR-J44LA 800MR-J42LA 800MR-J43LA S M M 800MR-J50LA 800MR-J52LA M M S 800MR-J38LA 1 N S M S 800MR-J631LA A M M M 800MR-J44 800MR-J42 800MR-J43 S M M 800MR-J50 800MR-J52 Right A M M S 800MR-J38 2 N S M S 800MR-J631 Note: = Closed/ = pen Key removable in locked position only. 800MR J H 2 L A a b c d e e 1 f (Selector Switch) 800MR J 41 L A a b c 1 c 2 d e e 1 f (Cylinder Lock)

12 a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Maintained Code Description Code Code Code Description Code Description J 3-position selector switch No knob 2 Maintained 41 Lock in left J 3-position cylinder lock H lack K 4 Spring return from left 42 Lock in center lank Key lank 5 Spring return from right 43 Lock in right 9 Spring return from both 44 Lock in all positions 45 Lock in left and center 46 Lock in right and left 47 Lock in right and center Spring Return From Code Description 50 Lock in center 52 Lock in right 51 Lock in right and center Spring Return From Right Code Description 69 Lock in left 38 Lock in center 73 Lock in left and center Spring Return From and Right Code Description 631 Lock in center c 2 d e e 1 f Key Codes Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type 1T Master Series Standard Description Code Key No. Code Description Code Description Code side Right side Code Description lank T100 (standard) cam lank oth left and right lank No contacts lank Stab terminals 02 T101 K K cam L A 1 N..-1 K Large screw 03 T102 P P cam R Right A3 1 N..E.M.-1 L.. 04 T106 U U cam 1 N T107 P1 2 N.. 1 N.. 2T Master Series P2 2 1 Code Key No. P3 2 N T109 P4 2 1 N.. 08 T134 P5 2 N.. 2 N.. 09 T135 P T136 P7 2 N.. 1 N T147 P8 2 1 N P9 1 N.. 1 T1 1 N Note:See Table 1 for cam and contact block selection. Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L or R. Contact cartridge position code (Table e) must be --. Table 1. Selector Switch Cam Targets

13 Note: = Closed/ = pen Cam Description Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. 4-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-NH2Q Knob Lever perator 800MR-NK2Q Contact Type Color Contact perator Position perator Type Standard Knob Knob Lever lack A Maintained in All Positions 800MR-NH2Q 800MR-NK2Q 2 N Right A Note: = Closed/ = pen Cylinder Lock perator 800MR-N31Q Contact Type Contact perator Position perator Type Cylinder Lock Lock In All Lock In Position 1 Lock In Position 2 A Maintained in All Positions 800MR-N61Q 800MR-N31Q 800MR-N32Q 2 N Right A Note: = Closed/ = pen Key removable in locked position only.

14 800MR N H 2 Q a b c d e f (Selector Switch) 800MR N 31 Q a b c 1 c 2 d e f (Cylinder Lock) a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Standard Key Code Description Code Code Code Description Code Description N 4-position selector No knob 2 Maintained 31 Lock in position 1 N 4-position cylinder lock H lack K 32 Lock in position 2 lank Key lank 33 Lock in position 3 34 Lock in position 4 41 Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in all positions c 2 d e f Key Codes Cam Type and Target Table Contact Cartridges Contact lock Termination Type Code Key No. Master Key Q Standard lock/stab Terminations Code Description lank T100 (standard) 1T Target Contact Type (Rear View) Code Description lank Stab terminals 02 T101 1T Right lank No contacts K Large screw 03 T102 1T 1 N.. 2 N T106 1T 1 05 T107 1T 1 N.. 07 T109 2T 1 08 T134 2T Note: = Closed/ = pen 09 T135 2T 10 T136 2T 14 T147 2T Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and knob levers must be ordered separately. Key removable in locked position only. perators are maintained in all positions. If no optional key code is specified, the standard key (T100) will be supplied. Logic Reed and small screw contact blocks must be ordered separately. 2-Position Knob/Lever Type Selector Switch Units, Illuminated

15 Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24HA2RA Knob Lever perator 800MR-24HL2RA Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Transformer 120V AC Red Full Voltage 24V AC/DC LED Red Transformer 120V AC Red M M 800MR-24HA2RA 800MR-24HL2RA S M 800MR-24HA4RA 800MR-24HL4RA M S 800MR-24HA5RA 800MR-24HL5RA M M 800MR-16HA2RA 800MR-16HL2RA S M 800MR-16HA4RA 800MR-16HL4RA M S 800MR-16HA5RA 800MR-16HL5RA M M 800MR-24HAL2RA 800MR-24HLL2RA S M 800MR-24HAL5RA 800MR-24HLL5RA M M 800MR-16HAL2RA 800MR-16HLL2RA S M 800MR-16HAL4RA 800MR-16HLL4RA 1 N M S 800MR-16HAL5RA 800MR-16HLL5RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. Target tables are reversed from those shown. 3-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24JA2RA Knob Lever perator 800MR-24JL2RA

16 Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red M M M 800MR-24JA2RA 800MR-24JL2RA S M M 800MR-24JA4RA 800MR-24JL4RA S M S 800MR-24JA9RA 800MR-24JL9RA Transformer 120V AC Red M M M 800MR-16JA2RA 800MR-16JL2RA S M M 800MR-16JA4RA 800MR-16JL4RA S M S 800MR-16JA9RA 800MR-16JL9RA Full Voltage 24V AC/DC LED Red M M M 800MR-24JAL2RA 800MR-24JLL2RA S M M 800MR-24JAL4RA 800MR-24JLL4RA S M S 800MR-24JAL9RA 800MR-24JLL9RA Transformer 120V AC Red M M M 800MR-16JAL2RA 800MR-16JLL2RA S M M 800MR-16JAL4RA 800MR-16JLL4RA 1 N S M S 800MR-16JAL9RA 800MR-16JLL9RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR 24 H A L 2 R A a b c d e f g 1 g 2 h (2-Position) 800MR 24 J A L 2 R A a b c d e f 1 g 1 g 2 h (3-Position) a b c Input Voltage perator Positions perator Color and Type Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code 12 12V AC/DC H 2-position No knob 24 24V AC/DC J 3-position A Red L V AC Green M Transformer D Amber P Code Description Y Clear Z V AC 50/60 Hz V AC 50/60 Hz d e f f 1 Illumination ptions perator Function Cam Type (2-Position) Cam Type (3-Position) Code Description Code Description Code Description Code Description lank Incandescent 2 Maintained cam cam L LED 4 Spring return from left Note:For Target arrangements see Table 1. K K cam 5 Spring return from right P P cam 9 Spring return from both U U cam Note:For Target arrangements see Table 2.

17 g 1 g 2 h Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Description lank oth right and left Code side Right side Code Description R Right lank No contacts lank Stab terminals A 1 N..-1 K Large screw A2 2 N.. A3 1 N..E.M.- 1 L.. A4 2 1 N N..-1 D1 1 N.. D2 1 P1 2 N.. 1 N.. P2 2 1 P3 2 N.. 1 P4 2 1 N.. P5 2 N.. 2 N.. P6 2 2 P7 2 N.. 1 N..-1 P8 2 1 N..-1 P9 1 N.. 1 N.C T1 1 N Note: See Table 1 for 2-position contact block selection. See Table 2 for 3-position contact block selection. nly available with LED Illumination option. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. nly available with full voltage power module and standard stab terminations. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table g1) must be R. Contact cartridge position code (Table g1) must be --. nly available for 2 position selector switches. Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Return From Right Spring Return From N.. N.. Note: = Closed/ = pen Table 2. Selector Switch Cam Targets Cam Description (3-Position) Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. Note: = Closed/ = pen 4-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations

18 perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24NA2Q Knob Lever perator 800MR-24NL2Q Contact Type Type Volts Lamp Color perator Position perator Type Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Maintained in All Positions 800MR-24NA2Q 800MR-24NL2Q 24V AC/DC LED Red 800MR-24NAL2Q 800MR-24NLL2Q 2 N V AC LED Red 800MR-10NAL2Q 800MR-10NLL2Q Note: = Closed/ = pen 800MR 24 N A L 2 Q a b c d e f g h (4-Position) a b c d Input Voltage perator Positions perator Color and Type Illumination ptions Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code Code Description 12 12V AC/DC N 4 position No knob lank Incandescent 24 24V AC/DC A Red L L LED V AC Green M D Amber P Y Clear Z e f g h perator Function Cam Type and Target Table Contact Cartridges Contact lock Termination Type Q Code Standard knob function Target Contact Type (Rear View) Standard lock Code Description Code Description 2 Maintained Right 2 N lank Stab terminals 1 N N.. 1 Note: = Closed/ = pen Note: = Closed/ = pen

19 nly available with LED Illumination option. perator is maintained in all positions. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. Logic Reed contact blocks must be ordered separately. ul. 800MR - Potentiometers, Pilot Lights, and Wobble Sticks uild a Catalog Number Potentiometer perator nly This operator is suitable for mounting potentiometers or other small single turn rotary operated devices having 3/8 in. diameter bushings (1/4 3/8 in. long) and 1/4 in. diameter shaft (3/4 1 1/2 in. long), plus providing 600V electrical clearances to panel. Includes operator, instruction sheet, and graduated marking ring. This operator does not have a resistive potentiometer element. Potentiometer Unit 800MR-N37 Type Potentiometer perator nly (without Resistive Element) 800MR-N37 Pilot Light Units Contact Terminations perators come standard with stab terminations. To order large screw contact terminations for pilot lights add letter K to the end of the cat. no. For push-to-test pilot lights add the letter K. Pilot Light 800MR-Q24R Push-to-Test Pilot Light 800MR-QT24R

20 Lamp Type Volts Color Pilot Light Push-to-Test Dual Input Incandescent Full Voltage 12V AC/DC Red 800MR-Q12R 800MR-QT12R Green 800MR-Q12G 800MR-QT12G Amber 800MR-Q12A 800MR-QT12A 24V AC/DC Red 800MR-Q24R 800MR-QT24R Green 800MR-Q24G 800MR-QT24G Amber 800MR-Q24A 800MR-QT24A Transformer 120V AC 50/60 Hz Red 800MR-P16R 800MR-PT16R 800MR-PDT16R Green 800MR-P16G 800MR-PT16G 800MR-PDT16G Amber 800MR-P16A 800MR-PT16A 800MR-PDT16A LED Full Voltage 24V AC/DC Red 800MR-QL24R 800MR-QTL24R Green 800MR-QL24G 800MR-QTL24G Amber 800MR-QL24A 800MR-QTL24A 120V AC Red 800MR-QL10R 800MR-QTL10R Green 800MR-QL10G 800MR-QTL10G Amber 800MR-QL10A 800MR-QTL10A Transformer 120V AC 50/60 Hz Red 800MR-PL16R 800MR-PTL16R Green 800MR-PL16G 800MR-PTL16G Amber 800MR-PL16A 800MR-PTL16A Dual input transformer is transformer relay type. Comes standard with screw terminations. 800MR P L 24 R a b c d e a b c perator Illumination ptions Input Voltage Transformer Full Voltage Code Description Code Description Code Description P Pilot light lank Incandescent 12 12V AC/DC PDT Pilot light dual input transformer L LED 24 24V AC/DC PT Pilot light push to test V AC Full Voltage Transformer Code Description Code Description Q Pilot light V AC 50/60 Hz QT Pilot light push to test V AC 50/60 Hz d e Lens Color Contact lock Termination Type Pilot Lights Code Color Code Description lank No lens lank Stab terminals A Amber K Large screw lue Note:If large screw terminations are desired with a dual input transformer, ( 800MR PDT ), configurator space e must be left blank. C G R W Clear Green Red White

21 LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED illumination option. Small screw contact blocks must be ordered separately. nly available with Push to test units. Wobble Stick Units Designed for ease of operation. Wobble stick units have spring return action and may be operated from any angle. It is particularly useful with pendant stations. Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations are sold separately. Wobble Stick Unit 800MR-M1 Contact Type Contact Type 1 N MR-M1A 2 N MR-M1 800MR M1 A a b c a b c perator Type Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description M1 Wobble stick lank No contacts lank Stab terminals A 1 N K Large screw 2 N Logic Reed and small screw contact blocks must be ordered separately. Specifications

22 Electrical Ratings Contact Ratings Dielectric Strength Electrical Design Life Cycles Refer to the Contact Ratings tables below. 1600V for one minute 1300V for one minute (Logic Reed) at maximum rated load at maximum rated load (Logic Reed) Mechanical Ratings Vibration Shock Degree of Protection Hz 1.52 mm displacement (peak to peak) Max./10 G Max. (except Logic Reed) 1/2 cycle sine wave for 11 milliseconds ³ 25 G (contact fragility) and no damage at 100 G Type 13; IEC I44 IP65 iltight Mechanical Design Life Cycles Push uttons Potentiometers All other devices Contact peration minimum minimum minimum Contact blocks with ifurcated spanner:slow make and break, simple break. Logic Reed Contact locks:snap-action Typical perating Forces perators without contact blocks 2.45 lb (10.8 N) Push-Pull Units 8 lb (35.3 N) push to in position 4 lb (17.7 N) maximum pull to out position Contact locks Standard 1.5 lb (6.7 N) Logic Reed lb (2.6 N) Environment Temperature Range perating F (0 55 C) Storage F ( C) Note:perating temperatures at +32 F (0 C) are based on the absence of freezing moisture and liquids. Humidity Panel Thickness Requirements 50% at 104 F (40 C) 1/16 1/4 in. ( mm) Performance Data See Performance Data. Standard Contact Ratings (IEC 337-1) (NEMA ICS 2-125) Maximum continuous current I th 10 A. ulletin 800M units have control circuit ratings with 800M contact blocks as follows: Maximum perational Volts Ue Utilization Category Rated perational Currents IEC NEMA Volts Ue Make reak AC 300 AC-II A VA 720 VA VA 720 VA A 10 A For applications below 24V and 24 ma, Logic Reed contacts are recommended. Logic Reed Contact Ratings Maximum: 150V AC, 0.15 A, 8 VA and 30V DC, 0.06 A, 1.8 VA. Should only be used with resistive loads. Wire Capacity Stab Termination Contact locks Accepts two x in. push-on connectors or one x in. push-on connector. Small Screw Contact locks Accepts one #14 or two #16 AWG solid or stranded wires. Large Screw Termination Contact locks Accepts two #12 AWG solid or stranded wires. Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. ul. 800MR Extension in Front of Panel

23 Round Push utton Flush, Extended and Illuminated Extended Round Push utton Illuminated Flush Round Push utton Mushroom Round Selector Switch and Potentiometer and Standard Knob Panel Wobble Stick Unit Round Selector Switch and Potentiometer and Wing Lever Round Cylinder Lock Selector Switch Round Push-Pull Twist or Pull Release Units ul. 800M Front View of Square Units CAUTIN: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction. Unit without Insert and acklit Unit Square acklit with Guarded ezel Square acklit with Unguarded ezel Dual perator Unit ul. 800M Extension in Front of Panel Square Push utton Flush and Extended Square Push utton Large Extended Square Push utton Dual perator Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Extension ehind Panel Units with Quick Connect Terminal Contact locks (Typical View) Units Having Screw Terminals with Pressure Plate Contact locks (Typical View) Units Having Large Screw Terminals with Pressure Plate Contact locks (Typical View) Panel Depth Requirements 1/16 1/4 in. ( mm)

24 Dimension A Description Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Units with Quick Connect Terminals Units Having Small Screw Terminals with Pressure Plates Non-Illuminated 2-1/4 (57.2) 2-15/32 (62.7) 3-1/2 (88.9) 2-1/32 (51.6) 2-3/4 (69.8) 2-5/16 (59) 2-17/32 (64.3) 3-9/16 (90.5) 2-1/32 (51.6) 2-13/16 (71.4) Illuminated Full Voltage 2-1/4 (57.2) 2-1/4 (57.2) 2-15/32 (62.7) 2-3/4 (69.8) 2-25/32 (70.6) 2-25/32 (70.6) 2-17/32 (64.3) 2-13/16 (71.4) Transformer 2-23/32 (69.1) 2-23/32 (69.1) 2-29/32 (73.8) 3-3/32 (78.6) 2-25/32 (70.6) 2-25/32 (70.6) 2-31/32 (75.4) 3-5/32 (80.1) Non-Illuminated Units Having Large Screw Terminals with Pressure Plates 2-45/64 (68.6) 2-59/64 (74.2) 3-15/16 (100) 3-13/64 (81.4) Illuminated Full Voltage 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-13/64 (81.4) Transformer 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-35/64 (90.1) Approximate Mounting Dimensions Caution: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1 1/2 in. (38.1 mm) minimum centers in one direction. Large screw terminal contact blocks require a minimum vertical spacing of 1 37/64 in. (40 mm); selector switches with wing lever knobs require 2 1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1 1/2 in. (38.1 mm) minimum spacing. Shipping Weights in unces (kg) Type of Unit Weight Type of Unit Weight Push uttons Non-Illuminated 3-1/4 (0.09) Selector Switches Non-Illuminated 4 (0.11) Illuminated Full Voltage 3-1/2 (0.10) Illuminated Full Voltage 4 (0.11) Transformer 5 (0.14) Transformer 5-1/2 (0.16) Pilot Lights Pilot Light 2-1/4 (0.06) Push-Pull Units Non-Illuminated 4-1/2 (0.13) Push-to-Test 3 (0.09) Pilot Light 4-1/2 (0.13) Illuminated Full Voltage 4-1/2 (0.13) Push-to-Test 5 (0.14) Transformer 5-1/2 (0.16) Cylinder Lock 6 (0.17) Potentiometer Units 4 (0.11) Padlocking Cover 800MR-N6 When using a padlocking cover and depending upon the types of adjacent units involved, the minimum vertical or horizontal spacing may have to be increased for operating clearance.

25 Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Legend Plates Standard Half Round Legend Plate Standard Legend Plate Large Size Round Small/Large Legend Plate The ulletin 800MR large half round legend plates are not recommended for use with the twist release units because of the operator knob size. The legend plate is virtually unreadable. Push pull units can be mounted in a 1 1/4 in. minimum horizontal spacing when no legend plate is used. Vertical spacing is 1 1/2 in. when the ulletin 800MR large half round legend plate is used. These ulletin 800MR legend plates consist of ulletin 800T legend plates with 800MR N50 adapter rings. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Bulletin 800MR/800MB Push Buttons

Bulletin 800MR/800MB Push Buttons ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight

More information

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2 30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 10 Bulletin 800R Hazardous Location Stations Classes I and II Division 2/Zone 2 30.5 mm Mounting Hole Types4/13and4/4X/13 0 TABLE OF CONTENTS

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Allen-Bradley Spares

Allen-Bradley Spares 10 ulletin 800H Hazardous Locations Push uttons and Stations Classes I, II & III Divisions 1 & 2 3/4" - 14 NPSM arrel Type7&9 Explosion-Proof perators 0 TLE F CNTENTS Page Page Specifications...10-113

More information

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9 Product Overview Configured Pendant Stations -, -, -, and -button configurations -, -, and -speed push buttons IP, NEMA Type /X/ Finger-safe contact blocks uttons are flush-mounted with the enclosure to

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

Complete units: Selector switches ø 22mm

Complete units: Selector switches ø 22mm Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights Characteristics 1 Environment Protective treatment Standard version TH Ambient air temperature Storage C - 40 + 70 around the device Operation C - 25 + 70 for LED and neon bulb versions - 25 + 40 for incandescent

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol

More information

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10 Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge

More information

1.3. Pushbuttons and Indicating Lights.

1.3. Pushbuttons and Indicating Lights. .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

Signaling Lights. SLC40 Series Panel Mounted Annunciators. SLC 40 Series Annunciators

Signaling Lights. SLC40 Series Panel Mounted Annunciators. SLC 40 Series Annunciators SLC40 Switches & Pilot Lights SLC40 Series Panel Mounted Annunciators SLC 40 Series Annunciators SLC series panel mounted annunciators are an ideal alternative to mounting multiple pilot devices. Cluster

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

Bulletin 700-RTC Solid-State Timing Relay

Bulletin 700-RTC Solid-State Timing Relay Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,

More information

General data. 13/20 Siemens IC Overview Front plate mounting

General data. 13/20 Siemens IC Overview Front plate mounting General data Overview Front plate mounting D C B E A F D NSD0_00029b B C A A B C D E F Actuator Front plate Holder Contact block Lampholder Support element For actuators see page /25 to /62. For contact

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number Non-Illuminated Momentary Pushbutton Units Flush Button Extended Button Mushroom Button Jumbo Mushroom Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators Contact Type Button

More information

A W - A 2A R - 24D - 1

A W - A 2A R - 24D - 1 Knob-type Selector Switch A165S/W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

TWTD Series: Heavy duty switches built to last

TWTD Series: Heavy duty switches built to last ø0mm - TWTD Series iltight TWTD Series Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last features include: Variety of button sizes up to 9/6" (65mm) Rugged construction includes

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

General-purpose Relay

General-purpose Relay General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical

More information

OMRON MK-I / -S RELAY

OMRON MK-I / -S RELAY Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks

More information

Round Indicator Lights Mounting Hole Page

Round Indicator Lights Mounting Hole Page PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

Dispozitive de acţionare şi indicatori

Dispozitive de acţionare şi indicatori Actuators and indicators are used in control circuits for direct and remote management of operations, vital for industries, commercial establishments and domestic installations. The range offers reliability,

More information

General-purpose Relay

General-purpose Relay General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors All Sensors Retroreflective Polarized Retroreflective ClearSight TM Standard Diffuse Long Range Diffuse Extended

More information

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view) Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards IEC 97-5-1, EN 6097-5-1 Product certifications NEMKO. Special version: UL Listed A600-Q600, CSA A600-Q600 Protective treatment Standard version TH

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

The Superior Choice for Material Handling Equipment 22.5 mm 800FC

The Superior Choice for Material Handling Equipment 22.5 mm 800FC The Superior Choice for Material Handling Equipment 22.5 mm 800FC PENDANT STATIONS 3 HOLE ENCLOSURE 800FC-3Z 5 HOLE ENCLOSURE 800FC-5Z 7 HOLE ENCLOSURE 80FC-7Z 9 HOLE ENCLOSURE 800FC-9Z Position 1 * Position

More information

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE PUSHBUTTON SWITCH / SEECTOR SWITCH / IUMINATED PUSHBUTTON SWITCH PSA, PSA TYPE FEATURES 1 3 The PSA and SPSA types are oil-proof. The enclosure rating is IP65 (water-jet-proof type), covering wide applications.

More information

Details on the New G2RS

Details on the New G2RS New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Major 5001 Wire Stripper

Major 5001 Wire Stripper Major 5001 Wire Stripper F e a t u r e s Stripping of 14 to 30 awg wire without blade changes Complete or partial removal of the insulation Small space required 7" x 15" 120 VAC Power Virtually maintenance

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

Operation Manual February Opticom Infrared System

Operation Manual February Opticom Infrared System Operation Manual February 2008 Opticom Infrared System M195/196, M9192, M292, M9592, M592 Emitters M511, M521, M522 Detectors M262, M562 Phase Selectors M360, M560 System Chassis M5168, M5575 Interface

More information

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Polarized Transmitted Beam Fiber Optic All Sensors Retroreflective Retroreflective ClearSight TM Standard Diffuse

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Revolutionary High-performance High-quality Sensor with Built-in Amp can be adjusted in seconds because the optical axis coincides with the mounting axis. Highly visible spot on white

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

General Specifications

General Specifications Series M Miniature Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical Capacity

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS CSM_H3DS_DS_E_2_1 DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock.

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

10 to 30 VDC (10% max. permissable ripple peak-to-peak) R Background Suppression Sensor Photoelectric Sensor With Adjustable Setting Distance in Rugged Metal Housing H Stable detection regardless of material color or size of sensing object: 2% or less black/white

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications Key Features Full-range with a single 2.25" (57 mm) driver in a ported enclosure to deliver a 140 conical coverage pattern and clear, intelligible music and speech reproduction for flush-ceiling or pendantmount

More information

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101 CustomAS-Interface enclosures Overview There are two types of custom solutions for AS-Interface: The front panel module and the SIRIUS 3SB3 enclosed stations. NC Contacts AS-Interface enclosure Ordering

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

Universal Voltage Cabled Photoelectric E3JK

Universal Voltage Cabled Photoelectric E3JK Universal Voltage Cabled Photoelectric Small Cable Sensor with Complementary Outputs Universal AC/DC supply voltage Relay or NPN/PNP transistor output, light-on or dark-on operation Polarized retroreflective

More information

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin DEVICES COVERED IN THIS DOCUMENT: 46CE Cylinder Escutcheon Key locks and 46DT Dummy Trim Pull when dogged unlocks lever 46BE Blank Escutcheon Always operable 46NL Night Latch Key retracts latchbolt 46NK

More information

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551 .7 Pushbuttons and Indicating Lights Contents escription 30.5 mm Square Multifunction Watertight/Oiltight E30 Product Identification.................... Product Selection Operators..........................

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Accessories. Accessories

Accessories. Accessories Series 61 16mm 22.5mm 21 x 21mm 21 x 27mm IP65 5 250V INDITOR PUSHUTTON E-STOP KEYLOK SELETOR hoose one component from each of the coloured sections to assemble a complete switch. For other options or

More information

LED Neon Light Round

LED Neon Light Round LED Neon Light Round Part #: NEON -P RND HB 24VDC WHT lc con cab LED Neon Light Round SPECIFICATION 36 21.5 19.5 HORIZONTAL BEND 46.5 CST Length CST Custom Length 3 cuttable every 3.25 Operating Voltage

More information

Specifications. Safety Ratings. Standards. Safety Classification

Specifications. Safety Ratings. Standards. Safety Classification General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

General-Purpose Photoelectric Sensors with Self-Contained Amplifier General-Purpose Photoelectric Sensors with Self-Contained Amplifier HP Series The convenience of industry standards, plus reliability. Effective light axis alignment 50% power savings Prevention of accidental

More information

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management Reyrolle Protection Devices 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Description Solkor R & Solkor Rf

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

CALRAD 25 series - potentiometers

CALRAD 25 series - potentiometers 25 series - potentiometers audio /linear SUB-MINIATURE VOLUME CONTROLS Linear taper, extremely smooth for quiet operation. 1 2" dia. fits into 1 4" hole. Shaft 3 16" dia. Thread length 7 32", shaft length

More information

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Installation Instructions for 45HW & 47HW Electrified Mortise Locks Contents These installation instructions describe how to install your 45HW & 47HW Electrified Mortise Lock. Topics covered include: Finishing

More information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_

More information

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications. SMT TR series Surface mount tiny washable rocker switches istinctive features and specifications Entirely designed for surface mount Tape and reel packaging Reflow solderable High temperature plastic materials

More information

ø30 ARN/ARNS Series Mono-lever Switches Switches

ø30 ARN/ARNS Series Mono-lever Switches Switches ø0 ARN/ARNS Series Mono-lever Switches Switches Single lever offers up to four directions of control Mono-lever switches operate in four directions using a single lever. Switch contacts are actuated in

More information

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. YASKAWA DUAL ENCODER (PG) FEEDBACK CARD (PG-Z) INSTRUCTIONS Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. Package Contents:

More information

Installation Instructions

Installation Instructions VON DUPRIN Installation Instructions 98/9947WDC Concealed Vertical Rod Exit Device Wood Door Applications Devices covered by these instructions: 98/9947WDC Concealed Vertical Rod Device 98/9947WDC-F (Fire)

More information