BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES
|
|
- Clemence Marybeth Price
- 5 years ago
- Views:
Transcription
1 BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM
2 FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade Cells from the most reputed makes like Motech, JA, etc. Anti-reflective Coating on Cells. Anisotropically Etched Surface. Low Iron Ultra clear Tempered Glass from leading make like St. Gobain, etc. EVA High Quality EVA of Leading Makes like Bridgestone, etc. Better optical performance. Better Adhesion. Backsheet High Reflectance Backsheet of Leading Makes like Dupont, Krempel. Sealed IP65 with Inbuilt bypass Diodes. Connector Frame Screwless design. Sand Blasted Anodized Aluminum frame with higher tensile strength and better corrosion resistance. Heavy duty 400 kpa/m. With Rain Spouts. High Quality cable with MC type Connector.
3 Very high efficiency modules (Upto 5% module efficiency). Wide range of certified modules from to 80 Watts. Positive oriented power tolerance: 0% on lower side to +3%. Bypass Diodes to ensure power output even in case of shading. Reverse current protection. Plug and play (MC type Connector & cable included). Light weight. FEATURES Higher safety as modules are certified to IEC 6730, Safety Class II 000VDC (also save on cabling costs). All certified components from leading brands. DURABILTY Tests performed: Electric Isolation. Outdoor Exposure. Wet Leakage Current. Thermal Cycling (-40 C to +85 C). Thermal Shock. Humidity Freeze. Damp Heat Test (000H at +85 C, 85%RH). Hot-Spot. Salt Mist Test. UV Exposure. Outdoor Exposure (KWh/m²). Bypass Diode Thermal Test. Mechanical, Wind and Twist Loading. Hail Impact (5mm diameter ice ball at 3 m/s). WARRANTY Long term output warranty shall warrant if PV Module(s) exibits power output of less than 0% of the original minimum rated power specified at the time of sale within 0 years and less than 80% within 5 years after the date of sale to the customer. 5 Years Warranty against any manufacturing defects. 5 years APPLICATIONS Large Solar Farms Roof- Top Grid- Connect Rural Electrification Street Lighting Telecom Cathodic Protection Solar Pumping Railway & Traffic Signaling SMALL MODULES Small Modules also available from 50 Wp onwards up to 30 Wp for off Grid & Rural Application (Suitable for V Configuration). Qualified, IEC 65 : 005 Safety Tested, IEC 6730 ISO 00:000 Plant D V E
4 Poly - Crystalline Silicon Modules Technical Specifications (PCA to PCA0) MODELS Type of Cells PCA PCA PCA PCA Poly (Multi) Crystalline Silicon PCA PCA PCA Wattage (Wp) Volt. at Max. Power (Vmp) Open Circuit Volt. (Voc) Current at Max. Power (Imp) Short Circuit Curr. (ISC) Number of cells per module Dimensions (mm) 34 X 0 34 X 0 34 X 0 48 X 0 48 X 0 48 X X 0 X 40 X 40 X 40 Weight (kg) Technical Specifications (PCA0 to PCA80) MODELS Type of Cells PCA PCA PCA PCA Poly (Multi) Crystalline Silicon PCA PCA PCA Wattage (Wp) Volt. at Max. Power (Vmp) Open Circuit Volt. (Voc) Current at Max. Power (Imp) Short Circuit Curr. (ISC) Number of cells per module Dimensions (mm) 640 X X X 0 50 X 0 50 X 0 50 X 0 50 X 0 Weight (kg) Common Specifications to all Models Frame Front Glass Oper. Temp. ( Deg. C) Relative Humidity Max. System Voltage NOCT Anodized Aluminium Tempered 3. mm -40 to to 00% 000 VDC 46 C +/- C IP 65 Connector MC4 * Temp. Coefficients Current(Isc) : 0.07%/ C ; Voltage(Voc) : %/ C ; Power( Pmax) : %/ C Reverse current protection 5 Amps Application class Class A All Electrical Parameters apply to Standard Test Conditions (STC) : 000W/m², AM.5, 5 C
5 PCA - 48 Cells Modules PCA - 54 Cells Modules Label Bar Code Ø4 Places mm mm 74 8 Places Ø x X0 50 PCA - Cells Modules Label Bar Code 34 Ø4 Places 00mm mm 66 8 Places Ø x X0 40 PCA - 7 Cells Modules Label Label Bar Code Bar Code 640 Ø4 Places Ø4 Places mm mm 00mm mm 80 8 Places Places Ø x X Ø x X0 50 I-V Curve (Cell Characteristics) INTENSITY DEPENDENCE 8.0 Intensity [W/m ] Isc* [ma].0 0. Voc* [mv] *Ratio of Voc(Isc) at reduced intensity to Voc(Isc) at 000 W/m Specifications are subject to change without prior notice.
6 Mono - Crystalline Silicon Modules Technical Specifications (MCA to MCA 0) MODELS MCA MCA 65 MCA 70 MCA 75 MCA 80 MCA 85 MCA 0 Type of Cells Mono Crystalline Silicon Wattage (Wp) Volt. at Max. Power (Vmp) Open Circuit Volt. (Voc) Current at Max. Power (Imp) Short Circuit Curr. (ISC) Size of Cells (mm) Cells per Module Dimensions (mm) Weight (Kg) Diodes Connector 5 X X 808 X bypass MC4 Cable Cross section : 4.0mm² ; Length : 00 mm Technical Specifications (MCA 0 to MCA 50) MODELS MCA 0 MCA 5 MCA 0 MCA 5 MCA 30 MCA MCA 40 MCA 45 MCA 50 Type of Cells Mono Crystalline Silicon Wattage (Wp) Volt. at Max. Power (Vmp) Open Circuit Volt. (Voc) Current at Max. Power (Imp) Short Circuit Curr. (ISC) Size of Cells (mm) Cells per Module Dimensions (mm) Weight (Kg) Diodes X X bypass Connector Cable MC4 Cross section : 4.0mm² ; Length : 00 mm Common Specifications to all Models Frame Anodized Aluminium Front Glass Tempered 3. mm Oper. Temp. ( Deg. C) -40 to +85 Relative Humidity 0 to 00% Max. System Voltage 000 VDC NOCT 45 C +/- C IP 65 Temp. Coefficients Current(Isc) : 0.0%/ C ; Voltage(Voc) : %/ C ; Power( Pmax) : %/ C * Reverse current protection 0 Amps Application class Class A All Electrical Parameters apply to Standard Test Conditions (STC) : 000W/m², AM.5, 5 C
7 Other Details (MCA- to MCA-0) 808± 758± IV curves at various irradiance levels 40± ± Cell Temperature = 5 C 6 000W/m² W/m² 500W/m² 00W/m² 580± - Ø ± 300± ± 00mm mm C 50 C 5 C ± 8- Ø x C -5 C Other Details (MCA-0 to MCA-50) 0± 004± IV curves at various irradiance levels 40± ± Cell Temperature = 5 C W/m² 800W/m² 500W/m² 00W/m² 580± - Ø ± 300± ± 40± 00mm mm 8- Ø x C 5 50 C 4 5 C 3 0 C -5 C IRRADIANCE-AM.5, 000w/m² Specifications are subject to change without prior notice.
8 Accessories Inverters Grid Connect Grid Connect String Inverters Different model upto.5 Kw High Efficiency (upto 7.5%) MPPT technology Standard Protections in-built Inverters Off-Grid Pure Sinewave High Efficiency Available Models with chargers & without chargers Different Models upto 8 Kw MPPT Chargers High Efficiency Upto 8% Available in V / 4 V / 48V Available upto maximum 0 amps TM Distributor / Dealer / Agent Novergy Energy Solution Pvt. Ltd. Navlok Navrartna Comp., Bedla Road, Udaipur- 3300, India Phone : , 45487, Fax sales@novergy.net, info@novergy.co.in
Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty
Those who dream of a better future can help lead to a more meaningful and enriched world. As a leading solar module manufacturer in Korea, we never stop to achieve competitiveness through differentiation,
More informationGrowatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range
Growatt 2000TL Maximum efficiency of 97% and wide inpunt voltage range Internal DC switch Transformerless GT topology Compact design Multi MPP controller MTL - String Bluetooth / RF technology / ZigBee
More informationUpsolar Smart Modules
Upsolar Smart Modules Optimized by Energy Improve ROI with No Upfront Cost Smart Modules optimized by Energy deliver more energy, active management and enhanced safety through state-ofthe-art module-embedded
More informationTEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval
Test Report issued under the responsibility of: TEST REPORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference
More informationAPPENDIX V PRODUCT SHEETS
National Institutes of Health Building 37 Modernization Bethesda, Maryland APPENDIX V PRODUCT SHEETS Katie L. McGimpsey Mechanical Option 1 of 4 BP 4160 160-Watt Monocrystalline Photovoltaic Module The
More informationYour Origin SLIVER system will be supplied with one of the following sets of panels:
SLIVER3000 Solar System Panel Specifications Your Origin SLIVER system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum
More informationKIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador
KIT SOLAR ANET O 7500 Wh/día QUÉ PUEDES CONECTAR? QUÉ INCLUYE? 9 Módulos FV T RINA SOLAR 255Wp Policristalino (3 Estructuras incluidas) 24 Baterías T URBO ENERGY 8 SOPZS 1400 1 Inversor/cargador/regulador
More informationSunny Smile with Hyundai
Happy Energy for the Future! Sunny Smile with Hyundai Advanced Green Solution beyond the world Hyundai Heavy Industries Happy Energy for the Future Hyundai Heavy Industries provides green solution for
More informationQuality criteria and certificates
Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years
More information60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof
EN LG300N1K-G4 60 cell LG s new module, NeON 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. NeON 2 Black demonstrates
More informationType EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets
Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years
More informationPage 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37
Page 1 of 37 Test Report issued under the responsibility of: TEST REPORT IEC 61215 PV Module Safety Qualification Requirements for testing Report Reference No.... : ULI-NABL(ELT)-MNRE-0053/2011 Date of
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC
TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19630874.001 Bangalore JULY 2016 Certificate No.
More information1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr
1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS topsun.kr About Topsun Strategy Our people are key to success. As a gloabl solar This applies to every It s based on our vision The focus lies
More informationTESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING /ALLOWED SUBCONTACTING = equired by Lab S = May be subcontracted 10.1 Visual inspection
More informationTest Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China
Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology
More informationApplication Note: String sizing Conext CL Series
: String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation
More informationmono-crystalline silicon solar cells mm No. of cells and connections 72(6 12)
Rated Maximum Power (P ma x) Current at P max (Imp ) Voltage at P max (V mp) Short-Circuit Current (I SC ) Open-Circuit Voltage (V OC ) Nominal Operating Temp.(T N OCT ) ll technical data at STC:1000W/m
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC
TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19631432.001 Bangalore July 2017 2 / 19 Contents:
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report
TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T -1543 2 / 17 Contents CONTENTS... 2
More informationFSEC APPROVAL # XL15-NT
AC GEC 4 IN SERIES TO UTILITY METER IN SERIES F-2 35A SW 60A SOLAR MODULE POWER BOX PM-25 270W 2 3 4 JUNCTION BOX 2 7 INVERTER I 6,000W 5 6 3 TO MAIN SERVICE ENTRANCE RE F. MODULES FSEC APPROVAL # XL5-NT90-02
More informationLaboratory 2: PV Module Current-Voltage Measurements
Laboratory 2: PV Module Current-Voltage Measurements Introduction and Background The current-voltage (I-V) characteristic is the basic descriptor of photovoltaic device performance. A fundamental understanding
More informationTECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.
TECHNICAL DATA SHEET smartflower POP. TECHNICAL DATA POWER OUTPUT Nominal output Output through 2-axle tracking POP 2.31 kwp* 3.400 5.700 kwp/a** SYSTEM Modultype Modul power output warranty Module product
More informationUnderstanding Temperature Effects on Crystalline PV Modules
Understanding Temperature Effects on Crystalline PV Modules The following is a discussion on temperature and how it affects solar module voltages and power output. This is particularly important in solar-battery
More informationThis document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB
This document contains TDS for the following products: Virtus II Module 55-70W 4BB ReneSola Australia Virtus II Module 60-70W 4BB Virtus II Module 55-70W 4BB 1000V US Virtus II Module 55W 60W 65W 70W High
More informationDongfang Electric Group Dongqi Investment&Development Co.,Ltd.
Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Documents for TUV Certification ADDRESS: 666 West Jinshajiang Road,Deyang City,Sichuan Province, P.R.China 61201 2010-09-05 Catalogue 01 General
More informationMarking label of DelSolar module type D6M240B3A
age 2 of 19 Report Ref. No. 61.410.11.029.01 Summary of testing: Tests performed (name of test and test clause): Testing location: Clause 6, Initial measurements: - Visual inspection - Maximum power determination
More informationReference: Photovoltaic Systems, p
PV systems are comprised of building blocks of cells, modules and arrays to form a DC power generating unit with specified electrical output. Reference: Photovoltaic Systems, p. 115-118 Reference: Photovoltaic
More informationTest Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China
Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology
More informationPID: an invisible danger for solar systems and how to prevent it
PID: an invisible danger for solar systems and how to prevent it PV Magazine Quality Roundtable Intersolar, st June Andrea Viaro, Head of Technical Service & Product Mgmt. Europe Total Quality Management.
More informationNew Tools for PV Array Commissioning and Troubleshooting
New Tools for PV Array Commissioning and Troubleshooting June 30, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass Sales Engineer bryan@solmetric.com Solmetric Solutions
More informationPag 1 of 15. Eurotest Laboratori S.r.l. Via Marconi, Brugine (PD) Italy
Pag 1 of 15 TEST REPORT IEC 82/685/NP (not ACCREDIA accredited) IEC 60068-2-78 IEC 61215 IEC 61730-2 System voltage durability test for crystalline silicon modules Design qualification and type approval
More informationTest Report. File No.: SHV01032/18-02 Test Report No.:
File No.: SHV01032/18-02 No.: 492011003.001 Applicant... : Manufacturer 1... : Manufacturer 2... : Order No.... : Suzhou Akcome Optronics Science &Technology Co., Ltd. Jintang Rd, Zhangjiagang Economic
More informationSILICon IrrADIAnCe SenSor
Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic
More informationPLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT
PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web:
More informationSolmetric PVA-600 PV Analyzer
Introducing the Solmetric PVA-600 PV Analyzer Paul Hernday PV Applications Engineer http://www.solmetric.com/pva600.html Bryan Bass Sales Engineer Topics Introduction to Solmetric Verifying PV array performance
More informationPORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER
PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER Daniel Schär 1, Franz Baumgartner ZHAW, Zurich University of Applied Sciences, School of Engineering, IEFE www.zhaw.ch/~bauf, Technikumstr. 9,
More informationTraditional PWM vs Morningstar s TrakStar MPPT Technology
Traditional PWM vs Morningstar s TrakStar MPPT Technology Morningstar s MPPT charge controllers use our patented TrakStar advanced control MPPT algorithm to harvest maximum power from a Solar Array s peak
More informationDr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece
Innovation Week on PV Systems Engineering and the other Renewable Energy Systems. 1-10 July 2013, Patras, Greece Dr E. Kaplani ekaplani@teipat.gr Mechanical Engineering Dept. T.E.I. of Patras, Greece R.E.S.
More informationFireFly Green. It is a self-contained laser that offers the user increased stability over a wide operating temperature and with a faster warm up time.
FireFly Green FireFly Green The FireFly Green range sets a new standard for industrial grade, green laser diode modules. A radically new design provides TE stabilised performance without TE cost and power
More informationOptical Information. The LDM145 laser diode modules are available with the following lens types.
LDM145 Datasheet LDM145 The LDM145 is a 16mm diameter CW laser diode module available in wavelengths of 520, 635, 650, 670, 780 & 850nm with power of up to 5mW as standard. It reuires an operating voltage
More informationAcculase Green PWM. Direct Drive Green Laser Diode Module
Acculase Green PWM Direct Drive Green Laser Diode Module Acculase Direct Drive Green Available in 520nm wavelength and with powers output powers up to 35mW the Acculase Direct Drive Green PWM represents
More informationTools for field testing
Tools for field testing Gianluca Corbellini - SUPSI October 6 th 2015 1 Agenda 1. Introducing SUPSI 2. Context of PV testing 3. State of the art field testing 4. Procedure for inverter testing 5. Procedure
More informationHow to Evaluate PV Project Energy Yield
How to Evaluate PV Project Energy Yield There are three main characteristics of a PV module that could affect the real energy generation of a PV plant: Temperature coefficient; Low light performance; IAM
More informationNew Tools for PV Array Commissioning and Troubleshooting
New Tools for PV Array Commissioning and Troubleshooting Solmetric PVA-600 Megger MIT430 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 April 5, 2012 Audio is available by telephone
More informationCP /240-MC4 User Manual
CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...
More informationNew Tools for PV Array Commissioning and Troubleshooting
New Tools for PV Array Commissioning and Troubleshooting November 10, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass R&D Engineer bryan@solmetric.com Solmetric
More informationGRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)
GRID-CONNECTED SOLAR PV SYSTEMS NO BATTERY STORAGE Design Guidelines for Accredited Installers January 2013 (Effective 1 February 2013) These guidelines have been developed by Clean Energy Council. They
More informationPV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer
PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer April 11, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Review of I-V Curves I-V and P-V
More informationUnderstanding Potential Induced Degradation for LG NeON Model
Understanding Potential Induced Degradation for LG NeON Model Table of Contents 2 CONTENTS 1. Introduction 3 2. PID Mechanism 4 3. LG NeON model PID Characterization 5 4. Description 7 6. Test Result 11
More informationAggressor 10 Watt Lightbar Series
Aggressor 10 Watt Lightbar Series SKU Range B6SRLB10W2P B6SRLB10W4P B6SRLB10W6P B6SRLB10W8P B6SRLB10W10P B6SRLB10W12P B6SRLB10W14P B6SRLB10W16P B6SRLB10W18P B6SRLB10W20P B6SRLB10W24P - 2 LED s - 4 LED
More informationIntroducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software
Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Next PVA Webinar November 29, 10am PST http://www.solmetric.com/ webinar.html Paul Hernday Senior Applications Engineer paul@solmetric.com
More informationColour your life! BISOL Spectrum Series. www. bisol. com
Colour your life! BISOL Spectrum Series www. bisol. com BISOL Spectrum Series With respect for our natural surrounding and the architectural legacy in mind, we are introducing an exclusive BISOL Spectrum
More informationModelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore.
6798 Available online at www.elixirpublishers.com (Elixir International Journal) Electrical Engineering Elixir Elec. Engg. 43 (2012) 6798-6802 Modelling and simulation of PV module for different irradiation
More informationPremier & Acculase Range Modular Modulatable Lasers
Premier & Acculase Range Modular Modulatable Lasers Features Flexible design accommodating wide range of lens and diode options High bore sight accuracy on Acculase model Visible and Infra red versions
More informationLIMITED WARRANTY AND SPECIFICATIONS. Kaneka Corporation (G-SA060)
LIMITED WARRANTY AND SPECIFICATIONS Between and Kaneka Corporation For Kaneka Thin film PV Modules (G-SA060) KANEKA CORPORATION OVERSEAS MARKETING SOLAR ENERGY DIVISION 3-2-4, NAKANOSHIMA,KITA-KU OSAKA
More informationThe series of Hawkeye detectors are designed as a companion
Hawkeye Laser Detector Features Compatible with the Global Premier, Acculase and Gated Cameo and our range of non-modulated lasers High level of immunity to ambient light High acceptance angle 160 deg
More informationDesign Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System
Design Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System Abstract Maximum power point tracking (MPPT) is a method that grid connected
More informationPage 1 of 19 Report Ref. No.: TEST REPORT IEC 62716:2013
age 1 of 19 Report Ref. No.: 704061718718-00 TEST REORT IEC 62716:2013 TÜV SÜD Test report for photovoltaic (V) modules Ammonia corrosion testing Report reference No.... : 704061806701-00 Date of issue...
More informationROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :
Technical Data TD ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationAPS M1P Single-phase Micro-inverter Installation and User Manual
APS M1P Single-phase Micro-inverter Installation and User Manual Version: 2.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR
More informationA Global Laser Brand. FireFly Mini
A Global Laser Brand FireFly Mini FireFly Mini Green The new FireFly Mini green range sets a new standard for small industrial grade, green laser diode modules. A radical new design provides TE stabilised
More informationPhotovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers
4097 PV Com & Test_CoverV3:Layout 2 28/6/12 09:41 USA Office: Seaward Group USA 6304 Benjamin Road, Suite 506, Tampa, Florida, 33634 Page 2 Part of Tel: +1 (813) 886-2775 Email: enquiry@seawardsolar.com
More information9. Grid-Connected of Photovoltaic Systems
9. Grid-Connected of Photovoltaic Systems H. Boileau Savoie University, FR Learning outcomes After reading this chapter, the user should possess knowledge of: A core description of PV systems connected
More informationPotential Induced degradation
Potential Induced degradation By: Waaree Energies Limited Abstract The PID defect is affecting all the manufacturers around the world. This defect is byproducts of the aggressive competition in the solar
More informationPV Array Commissioning and Troubleshooting. Solmetric PV Analyzer
PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer May 9, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Next webinar: May 30 http://www.solmetric.com/webinar.html
More informationAustralian Journal of Basic and Applied Sciences. Evaluation of Diode Model Parameters for a Solar Panel Simulation
ISSN:1991-8178 Australian Journal of Basic and Applied Sciences Journal home page: www.ajbasweb.com Evaluation of Diode Model Parameters for a Solar Panel Simulation 1 Thangavel Bhuvaneswari, 2 Venkatasessiah
More informationSTR9 RGBW Color Changing Linear Wall Washing and Grazing LED Lighting
STR9 DATE: TYPE: COMPANY: PROJECT: 600 598mm 23.5in 900 898mm 35.4in 1200 1198mm 47.2in 1500 1498mm 59.0in 72mm 2.8in 2.3in FEATURES: OPTIONS: Lighting Performance: Up to 2413 delivered lumens/meter (724
More informationDiode Collimator Assembly Datasheet
Diode Collimator Assembly Datasheet Diode Collimator Assembly Global Laser s DCA (Diode Collimator Assembly) provides a low cost high quality OEM solution to manufactures looking for a compact assembly
More informationTUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report
TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19630304.001 Bangalore, JULY 2015 Certificate No. T -1543 2 / 8 Contents CONTENTS... 2
More informationCommissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer
Commissioning and Troubleshooting PV Arrays with the Solmetric PV Analyzer November 14, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Topics Review of I-V Curves Introduction
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Display Devices & Components Company TECHNICAL DATA ROTANODE TM E7252X Rotating Anode X-Ray Tube Housing Assembly! High speed rotating anode X-ray tube housing assembly for high energy radiographic and
More informationABSOLUTE ROTARY ENCODER SSI
Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions
More informationPresented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell
Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada Introduction The The concept and PVA Characteristics Modeling Operating principles Control strategies
More informationWELCOME To APT - INDIA
WELCOME To APT - INDIA ADVANCED POWERTECH » WE ARE A SINGLE WINDOW SOLUTION FOR CUSTOMIZATION, DESIGN, DEVELOPMENT AND PRODUCTION FOR VARIOUS PRODUCTS WITH:- Full fledged R&D Latest Production Unit Modern
More informationPremier & Acculase Modulatable Laser Diode Modules
Premier & Acculase Modulatable Laser Diode Modules Premier & Acculase Range. The Premier & Acculase laser diode modules represent the highest level of optical and electrical performance at an economical
More informationPID Insulation Tester
SAFETY TESTER T O S 7 2 1 0 S ( S P E C 8 0 7 7 6 ) NEW S A F E T Y T E S T E R PID Insulation Tester (Potential Induced Degradation) TOS7210S Capable of setting within the range of 50 Vdc to 2000 Vdc
More informationHandouts for Mulanax Solar Panel Project
Handouts for Mulanax Solar Panel Project Student handouts/prints to be made from the book, Teaching Solar, by Rahus Institute. Page 5: Panel Orientation Page 8: Sun s Position Page 9: Azimuth Page 9: Altitude
More informationThe Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010
May 2010 The Nanosolar Utility Panel 1 Designed for Utility-Scale Performance The Nanosolar Utility Panel is specifically designed for utility-scale systems. Engineered to reduce totalsystem cost, the
More information26+ Year Old Photovoltaic Power Plant: Degradation and Reliability. Evaluation of Crystalline Silicon Modules North Array.
26+ Year Old Photovoltaic Power Plant: Degradation and Reliability Evaluation of Crystalline Silicon Modules North Array by Jonathan Belmont A Thesis Presented in Partial Fulfillment Of the Requirements
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationSOLARLOK PV BAR Junction Box
SOLARLOK PV BAR Junction Box Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 3 2. APPLICABLE DOCUMENTS... 3 2.1. TE Connectivity Documents... 3 2.2. Commercial Standard... 3 3.
More informationSupplemental Calculation Sheets for Inverter #2
Solar PV Standard Plan Simplified Central/String Inverter Systems for One and TwoFamily Dwellings (10 KW or Less) Supplemental Calculation Sheets for Inverter #2 FORM PV 3S DC Information: Module Manufacturer:
More informationINSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES
INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES - Page 1/13. Appendix II - CONTENT 1. INTRODUCTION...3 2. TECHNICAL DATA...3 3. PROTECTION DIODES...6 4.
More informationExample: ZX-BGS-DS300P-2M ZX Series - Diffuse Background Suppression Type - Distance Settable, 300mm Sensing Distance, PNP - 2m Cable
Laser Spot Sensor Background Suppression Type SALIENT FEATURES Ø1mm Spot size 250 µ sec Response External Laser Control Back Ground Suppression IP-67, Shock Resistant - 50G Measurement Class II LASER Product
More informationRotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I
Technical Data TD ROTANODE E7239X E7239FX E7239GX 197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially
More informationAPS M1P Single-phase Micro-inverter Installation and User Manual
APS M1P Single-phase Micro-inverter Installation and User Manual Version: 1.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR
More informationElgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator
Elgar ETS TerraSAS Standalone TerraSAS Photovoltaic Simulator Low output capacitance High bandwidth up to 30kHz High resolution I-V curve simulates static and dynamic conditions Designed for high speed
More informationPerformance Loss of PV systems. Giorgio Belluardo
Performance Loss of PV systems Giorgio Belluardo Content Importance of accurate estimation of PL Mechanisms behind performance loss Statistics Methodologies to assess PLR Novel method for estimation of
More informationSpun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf
Catalog number: ing Options: Ordered Separately from See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications 6K" DIA. (165.1 mm) Ordering Information 13J" (336.6 mm) K" NPT 2B" (54.0 mm) Source l S3/9L3KUV
More informationNext, know your supply voltage. It should be a few volts above the LED forward voltage for reliable, stable LED operation
4. handling 4.1. biasing LEDs The light generated by an LED is directly proportional to the forward current flowing through the device. Various biasing schemes can be used to set the value of the current.
More informationFor more information:
Verify Tab Click on the Verify tab to compare the measured and predicted max power values. Their ratio, in percent, is the Performance Factor. Solmetric PVA-600 PV Analyzer Quick Start Guide History Tab
More information300W Railway Single Output DC-DC Converter
SPECIFICATION MODEL OUTPUT INPUT PROTECTION WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 4) OTHERS NOTE OVER OVER VOLTAGE SAFETY STANDARDS
More informationTraditional PWM vs. Morningstar s TrakStar MPPT Technology
Traditional PWM vs. Morningstar s TrakStar MPPT Technology Introduction: Morningstar MPPT (Maximum Power Point Tracking) controllers utilize Morningstar s own advanced TrakStar Maximum Power Point Tracking
More informationEngineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin
Simulation of the effects of global irradiance, ambient temperature and partial shading on the output of the photovoltaic module using MATLAB/Simulink and ICAP/4 A report submitted to the School of Engineering
More informationIncremental encoders Blind hollow shaft or cone shaft pulses per revolution
Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80
More informationVarilite Datasheet. Thread Mountable Laser Diode Module
Varilite Datasheet Thread Mountable Laser Diode Module Varilite The Varilite range combines all the features of Global Lasers Premier range with the addition of a threaded barrel to simplify mounting and
More informationF T 742 NEW TOUGHEST WIND SENSORS THE WORLD S
F T 7 2 2+ F T 742 D ATA S H E E T NEW D E S I G N E D F O R T U R B I N E C O N T R O L THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM PROVEN NEW LOOK, NEW SPEED, SAME STRENGTH The FT722 and
More informationString Configuration Tool Help!
String Configuration Tool Help! (Siento, esto solo está en inglés) 1 Intended Use and Disclaimer Thank you for using the Fronius String Configuration Tool ( FSC Tool ) for North America. Fronius USA provides
More informationChapter 4. Impact of Dust on Solar PV Module: Experimental Analysis
Chapter 4 Impact of Dust on Solar PV Module: Experimental Analysis 53 CHAPTER 4 IMPACT OF DUST ON SOLAR PV MODULE: EXPERIMENTAL ANALYSIS 4.1 INTRODUCTION: On a bright, sunny day the sun shines approximately
More information