Signal Input and Trigger
|
|
- Dale Charles
- 5 years ago
- Views:
Transcription
1 Signal Input and Trigger Number of input channels 2 (CH A and CH B) Input coupling Input connector DC/AC BNC connector Input impedance 50Ω/1 MΩ, 23pF (typical value *1 ) Frequency characteristics When the input coupling is DC: DC to 250 MHz (typical value *1 ) When the input coupling is AC and Input impedance is 50 Ω: 680 khz to 250 MHz (typical value *1 ) Input impedance is 1 MΩ: 35 Hz to 250 MHz (typical value *1 ) Internal jitter 100 ps rms Minimum input pulse width 3 ns (2.2 ns for CH B when measuring A-to-B time interval) Operating voltage range 5 to 5 V Maximum input voltage When the input impedance is 50 Ω: 5 V rms When the input impedance is 1 MΩ and DC input frequency 100 khz: 40 V (DC+AC peak) 100 khz input frequency 100 MHz: {3.5/f+5} V (DC+AC peak), where f is the frequency in MHz Overvoltage category: I and II Input sensitivity *2 100 mv p-p Input amplifier noise 400µV rms (typical value *1 ) Cross talk when using the dual measurement function *3 40 db (typical value *1 ) Trigger Trigger mode: Select from single auto trigger, repeat auto trigger, and manual trigger. Trigger level (when using manual trigger) Selectable range: 5 to 5 V Accuracy *4 : (10 mv + 1% of the specified value) Resolution: 1 mv Trigger level (when using single auto trigger or repeat auto trigger) Selectable range: 0% to 100% Resolution: 1% Input condition when using single auto trigger or repeat auto trigger: Continuous signal between 1 khz and 50 MHz Setup time of single auto trigger and repeat auto trigger: 0.7 s (typical value *1 ) Phase Adjustment Function used to adjust the phase difference of CH B with respect to CH A when measuring A-to-B time interval, period A & A-to-B time interval, or pulse width A & A-to-B time interval Selectable range: 0 to 10.0 ns (resolution: 0.1 ns) Sampling Sampling mode: Select from time stamp mode, hardware histogram mode, and inter-symbol interference analysis mode Maximum sample rate When using the single measurement function *5 : 80 MS/s continuous (12.5 ns interval) When using the dual measurement function *3 : 50 MS/s continuous (20 ns interval) Maximum sample size (maximum number of data points) When in time stamp mode or inter-symbol interference analysis mode: 1,024,000 (512,000 when using the dual measurement function *3 ) When in hardware histogram mode: 10 9 Sampling interval (setting only when using the single measurement function* 5 in time stamp mode) 0µs to 1 s (resolution: 1 µs) Maximum sample rate when 0 µs is selected Longest sampling time When in time stamp mode or inter-symbol interference analysis mode: 320 s (time from when arming is activated) When in hardware histogram mode: 3200 s (time from when arming is activated) Update rate *1 400 ms (hardware histogram mode) Update rate when the sampling size (event size) is 1000 and period of a 1-MHz sine wave is measured. *1 Typical value represents a typical or average value. It is not strictly warranted. *2 Measured value under standard operating conditions with input coupling set to DC and input impedance set to 50 Ω after the warm-up time has elapsed. *3 Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, pulse width A & pulse width B, pulse width A A-to-B time interval, or pulse width A pulse width B measurement. *4 Measured value under standard operating conditions with input coupling set to DC and input impedance set to 1 MΩ after the warm-up time has elapsed. *5 Period, A-to-B time interval, or pulse width measurement. 1 15
2 Measurement Functions (Measurement s) Measurement function When in time stamp mode or hardware histogram mode Single measurement function Period, A-to-B time interval, and pulse width Dual measurement function Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, and pulse width A & pulse width B When in inter-symbol interference analysis mode Single measurement function Pulse width Dual measurement function Pulse width A A-to-B time interval and pulse width A pulse width B Display resolution When in time stamp mode: 25 ps When in hardware histogram mode, inter-symbol interference analysis mode, or time stamp mode when using multi window display: 25 ps or (X span of the histogram/600) whichever is greater Period measurement Measurement range When in time stamp mode: 6 ns to 20 ms When in hardware histogram mode: 6 ns to 3.2 µs 100 ps rms *1 2 trigger error *2 Accuracy *3 Measurement resolution (frequency stability of the time base measured value) 300-ps Slope: Select from or A-to-B time interval Measurement range measurement When in time stamp mode: 0 ns to 20 ms When in hardware histogram mode: 0 ns to 3.2 µs When the slope is set to A B, A B, A B, or A B : 100 ps rms *1 A input trigger error *2 B input trigger error *2 When the slope is set to A B or A B : 100 ps rms *1 A input trigger error *2 B input trigger error *2 trigger level timing error *4 Accuracy *3 When the slope is set to A B, A B, A B, or A B : Measurement resolution trigger level timing error (frequency stability of the time base measured value) 1-ns When the slope is set to A B or A B : Measurement resolution (frequency stability of the time base measured value) 1-ns Slope: Select from A B /A B, A B, A B, A B, and A B Continuous measurement condition: The time to the next A signal edge after the A-to-B time interval measurement is greater than equal to 0 ns and the time from the previous A signal edge is greater than or equal to 12.5 ns *1 100 ps rms or the display resolution whichever is greater when in hardware histogram mode, inter-symbol interference analysis mode, or time stamp mode using multi window display. *2 The trigger error, A input trigger error, B input trigger error, rising edge trigger error, and falling edge trigger error defined by the following equation. X 2 + W 2 + E 2 n SR X: Input amplifier noise, W: Cross talk noise (0.01 the signal amplitude of the other channel [Vrms]) En: Noise in the signal being measured [Vrms], SR: Slew rate of the input signal [V/s] *3 Measured value under standard operating conditions as described in General after the warm-up time has elapsed. *4 The trigger level timing error is defined by the following equation. Trigger level setting accuracy Trigger level setting accuracy Slew rate of the start signal Slew rate of the stop signal Slew rate of the start signal Slew rate of the stop signal 2
3 Pulse width measurement Measurement range When in time stamp mode: 6 ns to 20 ms When in hardware histogram mode: 6 ns to 3.2 µs When in inter-symbol interference analysis mode: 10 ns to 3.2 µs 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 trigger level timing error *3 Accuracy *4 Measurement resolution trigger level timing error (frequency stability of the time base measured value) 1-ns Measurement resolution (frequency stability of the time base measured value) 1-ns Polarity: Select from,, and ( only when in inter-symbol interference analysis mode) Period A & period B Measurement range measurement When in time stamp mode: 6 ns to 20 ms When in hardware histogram mode: 6 ns to 3.2 µs 100 ps rms *1 2 trigger error *2 Accuracy *4 Measurement resolution (frequency stability of the time base measured value) 300-ps Slope: Select from A &B or A &B Period A & A-to-B time Measurement range interval measurement When in time stamp mode Period measurement: 6 ns to 20 ms A-to-B time interval measurement: 0 ns to 20 ms When in hardware histogram mode Period measurement: 6 ns to 3.2 µs A-to-B time interval measurement: 0 ns to 3.2 µs Period measurement: 100 ps rms *1 2 trigger error *2 A-to-B time interval measurement: 100 ps rms *1 A input trigger error *2 B input trigger error *2 Accuracy *4 Period measurement: Measurement resolution (frequency stability of the time base measured value) 300-ps A-to-B time interval measurement: Measurement resolution trigger level timing error (frequency stability of the time base measured value) 1-ns Slope: Select from A &A B or A &A B Continuous A-to-B time interval measurement condition: The time to the next A signal edge after the A-to-B time interval measurement is greater than equal to 13 ns and the time from the previous A signal edge is greater than or equal to 20 ns *1 100 ps rms or the display resolution whichever is greater when in hardware histogram mode, inter-symbol interference analysis mode, or time stamp mode using multi window display. *2 The trigger error, A input trigger error, B input trigger error, rising edge trigger error, and falling edge trigger error defined by the following equation. X 2 + W 2 + E 2 n SR X: Input amplifier noise, W: Cross talk noise (0.01 the signal amplitude of the other channel [Vrms]) En: Noise in the signal being measured [Vrms], SR: Slew rate of the input signal [V/s] *3 The trigger level timing error is defined by the following equation. Trigger level setting accuracy Trigger level setting accuracy Slew rate of the start signal Slew rate of the stop signal Slew rate of the start signal Slew rate of the stop signal *4 Measured value under standard operating conditions as described in General after the warm-up time has elapsed. 3
4 Pulse A & A-to-B time Measurement range interval measurement and Time stamp mode or inter-symbol interference analysis mode pulse A A-to-B time Pulse width measurement: 6 ns to 20 ms, A-to-B time interval measurement: 0 ns to 20 ms interval measurement Hardware histogram mode Pulse width measurement: 6 ns to 3.2 µs, A-to-B time interval measurement: 0 ns to 3.2 µs Inter-symbol interference analysis mode Pulse width measurement: 10 ns to 3.2 µs, A-to-B time interval measurement: 0 ns to 3.2 µs Pulse width measurement 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 trigger level timing error *3 A-to-B time interval measurement When the slope is set to A B, A B, A B, or A B : 100 ps rms *1 A input trigger error *2 B input trigger error *2 When the slope is set to A B or A B : 100 ps rms *1 A input trigger error *2 B input trigger error *2 trigger level timing error *3 Accuracy *4 Pulse width measurement Measurement resolution (frequency stability of the time base measured value) trigger level timing error *3 1-ns Measurement resolution (frequency stability of the time base measured value) 1-ns A-to-B time interval measurement When the slope is set to A B, A B, A B, or A B : Measurement resolution (frequency stability of the time base measured value) trigger level timing error *3 1-ns When the slope is set to A B or A B : Measurement resolution (frequency stability of the time base measured value) 1-ns Polarity/Slope When in time stamp mode or hardware histogram mode: Select from A &A B and AA &A B When in inter-symbol interference analysis mode: Select from A &A B, A &A B, A &A B, A &A B, A &A B, and A &A B Continuous A-to-B time interval measurement condition: The time to the next A signal edge after the A-to-B time interval measurement is greater than equal to 13 ns and the time from the previous A signal edge is greater than or equal to 20 ns Pulse width A & pulse Measurement range width B measurement When in time stamp mode: 6 ns to 20 ms and pulse width A pulse When in hardware histogram mode: 6 ns to 3.2 ms width B measurement When in inter-symbol interference analysis mode: 10 ns to 3.2 µs (20 ns to 3.2 µs for pulse width B) 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 100 ps rms *1 rising edge trigger error *2 falling edge trigger error *2 trigger level timing error *3 Accuracy *4 Measurement resolution (frequency stability of the time base measured value) trigger level timing error *3 1-ns Measurement resolution (frequency stability of the time base measured value) 1-ns Polarity: Select from,, and ( only when in inter-symbol interference analysis mode) *1 100 ps rms or the display resolution whichever is greater when in hardware histogram mode, inter-symbol interference analysis mode, or time stamp mode using multi window display. *2 The trigger error, A input trigger error, B input trigger error, rising edge trigger error, and falling edge trigger error defined by the following equation. X 2 + W 2 + E 2 n X: Input amplifier noise, W: Cross talk noise (0.01 the signal amplitude of the other channel [Vrms]) SR En: Noise in the signal being measured [Vrms], SR: Slew rate of the input signal [V/s] *3 The trigger level timing error is defined by the following equation. Trigger level setting accuracy Trigger level setting accuracy Slew rate of the start signal Slew rate of the stop signal Slew rate of the start signal Slew rate of the stop signal *4 Measured value under standard operating conditions as described in General after the warm-up time has elapsed. 4
5 Gate, Arming, and Inhibit Gate Arming Inhibit The specifications for inter-symbol interference analysis mode conform to the specifications for time stamp mode. Gate types: Select from EVENT, TIME, and EXTERNAL When using the dual measurement function *2, the measurement terminates when the gate of each measurement closes. Selectable range of the event size when using event gate (within the longest sampling time) Time stamp mode or inter-symbol interference analysis mode Single measurement function *3 : 2 to Dual measurement function *2 : 1 to (for each measurement) Hardware histogram mode Single measurement function *5 : 2 to 10 9 Dual measurement function *2 : 1 to 10 9 (for each measurement) Selectable range of gate time when set to time gate (within the maximum event size of each sampling mode) 1 µs gate time 10 s (resolution is 100 ns) Allowable time and polarity when set to external gate Allowable time: 1 µs to 320 s (except within the maximum event size of the sampling mode) Polarity: Select from and External gate input (shared with external arming) Connector type: BNC Input coupling: DC input impedance: 1 MΩ (typical value *1 ) Trigger level: TTL (1.4 V), TTL/10 (0.14 V), or 0 V Maximum input voltage: 40 V (DC + AC peak) Minimum input pulse width: 30 ns Setup time: 60 ns (must precede the measurement signal by at least 60 ns for the gate to be valid). Arming source: Select from AUTO and EXT (external) External arming (EXT) setting Selectable range of delay time when set to time delay (set the time for each measurement when using the dual measurement function *2 ) 1 µs delay time 1 s (resolution is 100 ns) Selectable range of the event size when set to event delay (Set the value for each measurement when using period A & period B or pulse width A & pulse width B measurement. Event delay is possible when the frequency of event occurrence is less than or equal to 50 MHz.) 1 to 10 6 (resolution: 1) Slope: Select from and External arming input (shared with external gate) Connector type: BNC Input coupling: DC input impedance: 1 MΩ (typical value *1 ) Trigger level: TTL (1.4 V), TTL/10 (0.14 V), or 0 V Maximum input voltage: 40 V (DC + AC peak) Minimum input pulse width: 30 ns Setup time: 60 ns (must precede the measurement signal by at least 60 ns for the arming to be valid). Active time When in time stamp mode: 1 µs to 320 s When in hardware histogram mode: 1 µs to 3200 s Polarity: Select from and Inhibit input Connector type: BNC Input coupling: DC input impedance: 1 MΩ (typical value *1 ) Trigger level: TTL (1.4 V), TTL/10 (0.14 V), or 0 V Maximum input voltage: 40 V (DC + AC peak) Minimum input pulse width: 30 ns Setup time: 30 ns (must precede the measurement signal by at least 30 ns for the inhibit to be valid). *1 Typical value represents a typical or average value. It is not strictly warranted. *2 Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, pulse width A & pulse width B, pulse width A A-to-B time interval, or pulse width A pulse width B measurement. *3 Period, A-to-B time interval, or pulse width measurement. 5
6 Block Sampling Selectable range of the number of blocks Block rest mode Selectable range of the block rest time Selectable range of the block rest event size Restriction on use Time stamp mode When the arming source is EXT and the rest mode is OFF or when the arming source is AUTO and the rest mode is event or time: 2 to 250 When the arming source is AUTO and the rest mode is OFF: 2 to 1000 When in hardware histogram mode: 2 to 1000 The total sample size of all blocks is within the maximum sampling size (see page 15-1). Select from OFF, Time, and Event 1 µs to 1 s (resolution: 100 ns, accuracy: 200 ns) 1 to 10 6 (resolution: 1, rest time: 500 ns or more, frequency of event occurrence: 50 MHz or less, accuracy:1 event) Cannot be specified when using the dual measurement function *2, external gate, or when in intersymbol interference analysis mode. When the rest mode is set to event or time, external arming (EXT) cannot be used. *1 Period, A-to-B time interval, or pulse width measurement. *2 Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, or pulse width A & pulse width B measurement. Inter-symbol Interference Analysis Function Function Function used to extract the data around the spaces and marks of the specified condition, display the histogram, and calculate statistics. Measurement Function Pulse width, pulse width A A-to-B time interval, pulse width A pulse width B (Inhibit function cannot be used when using the dual measurement function *1 ) Minimum input pulse width 10 ns (pulse width B is 20 ns) Data extraction mode Select from Single, Combination and Between Data extraction condition Select from nt, nt to maxt, and mint to nt (n: arbitrary value between 1 and 16) Trigger Select mark or space Target Select the analysis data with respect to the trigger from Prev., Middle, Next, or Both Missed sampling fill Function used to fill the dropouts in sampling when using the dual measurement function *1 Maximum number of dropout samples that can be filled: 256 Conditions for filling the samples: When the dropout sampling interval is 100 ns or more Sync function Turn ON/OFF the function which starts the analysis from where the symbol search function found the desired symbol *1 Pulse width A A-to-B time interval or pulse width A pulse width B measurement Display Display Display size: 6.4 inches Display resolution: 640 (H) 480 (V) dots Display defect: 0.01% or less with respect to all the display dots Display format When in time stamp mode: Select from histogram, list, time variation, and statistics displays When in hardware histogram mode Select from histogram, list, and statistics displays When in inter-symbol interference analysis mode Select histogram or list Selection of the item to be analyzed when using the dual measurement function *1 MEAS1: Displays the measurement result of measurement function 1 MEAS2: Displays the measurement result of measurement function 2 *1 Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, pulse width A & pulse width B, pulse width A A-to-B time interval, or pulse width A pulse width B measurement. 6
7 Histogram display Scale: Sets the X-axis and Y-axis of the histogram Selectable range of X center (X-axis center) When in time stamp mode: 50 ns to ms (resolution: 25 ps) When in hardware histogram mode: 50 ns to µs (resolution: 25 ps) X Span When in time stamp mode: Select from 1.5, 3, 7.5, 15, 30, 60, 150, 300, 600ns, 1.5, 3, 6, 15, 30, 60, 150, 300, 600 ms, 1.5, 3, 6, 15, and 30 ms When in hardware histogram mode: Select from 1.5, 3, 7.5, 15, 30, 60, 150, 300, 600 ns, 1.5, 3, 6 µs Y axis (scale type): Select Lin (linear) or Log (logarithmic) Y High (Y-axis maximum) When the Y-axis scale is linear: Select from 10, 20, 40, 100, 200, 400, 1000, 2000, 4000, 10000, 20000, 40000, , , , 1e 6, 1e 7, 1e 8, and 1e 9 When the Y-axis scale is logarithmic: Select from 1e 1, 1e 2, 1e 3, 1e 4 1e 5, 1e 6, 1e 7, 1e 8, and 1e 9 Readout: Read out the value by positioning the X marker (marker display can be turned ON/OFF) Specify the statistical calculation area by specifying a frequency for the Y marker (marker display can be turned ON/OFF) Statistics display (can be turned ON/OFF) Area: Select the area for performing statistical calculation from Window or Marker A-to-B time interval measurement A B : Select the slope from A B, A B, A B, and A B &A B A-to-B time interval measurement A B : Select the slope from A B, A B, A B, A B &A B Pulse width measurement : Select the polarity from,,, and &. Pulse width A & A-to-B time interval measurement A &A B : Select from A &A B, A &A B, A &A B, A &A B, A &A B Pulse width A & A-to-B time interval measurement A &A B : Select from A &A B, A &A B, A &A B, A &A B &A &A B Pulse width A & pulse width B measurement: Select from A &B, A &B, A &B, A &B &A &B Selectable range of T Value (T value of statistical calculation: 1 ns to 250 ns (resolution: 25 ps) Multi window: Data analysis of multiple histograms Selectable range of window size: 1 to 14 Auto window: Automatic data analysis of multiple histograms Histogram sum (only when using the multi window or auto window) Sums the frequencies of all specified windows for each bin around the X-axis center of each window Display style Switch the graph size between half and full, turn ON/OFF the statistics display, turn ON/OFF the panorama display, turn ON/OFF the both polarities/both edges graph (Both Graph), and turn ON/ OFF the overlap of each polarity graph Select Stat, Dev, or σ when in hardware histogram mode or time stamp mode using the all display of the multi window or auto window Time variation display (only when in time stamp mode) Scale: Sets the X-axis and Y-axis of the time variation. Selectable range of X Min (X-axis minimum): 0 to s (resolution: 100 ns) Selectable range of X Span: Select from 6, 12, 30, 60, 120, 300, 600 µs, 1.2, 3, 6, 12, 30, 60, 120, 300, 600 ms, 6, 12, 30, 60, 120, 300, and 600 s Selectable range of Y Center (Y-axis center): 50 ns to ms (resolution: 25 ps) Y Span: Select from 500 p, 1, 2.5, 5, 10, 20, 50, 100, 200, 500 ns, 1, 2, 5, 10, 20, 50, 100, 200, 500 µs, 1, 2, 5, 10, and 20 ms Readout: Read the value by positioning the X and Y markers Statistics display (can be turned ON/OFF) Area: Select the area for performing statistical calculation from Window, Marker, and Block Display style Switch the graph size between half and full, turn ON/OFF the statistics display, turn ON/OFF the panorama display, turn ON/OFF the overlap of measured waveforms (when using the dual measurement function *1 ), select the display waveform (MEAS1, MEAS2, or MEAS1 & MEAS2) Display parameters: Turn ON/OFF the grid and interpolation, switch the plot mark between Pixel and Mark Time resolution of the X-axis (time stamp): 100 ns List display When in time stamp mode or inter-symbol interference analysis mode Lists the time stamps, corresponding measured values, and symbols Can be displayed for each block when block sampling is used Display data scrolling Symbol search function available (forward and backward search) Number of symbols to be searched: Select from 1 to 4 When in hardware histogram mode Lists the measured values (median values) and corresponding frequencies Display data scrolling *1 Period A & period B, period A & A-to-B time interval, pulse width A & A-to-B time interval, or pulse width A & pulse width B 7
8 Statistics display When in time stamp mode When the calculated item is histogram Statistical calculation parameters: Average, Maximum, Minimum, Peak-Peak, σ, σ/average, σ/t, Deviation, Deviation/T, Median, Mode, Number When calculation item is time variation Statistical calculation parameters: T.Average, T.Maximum, T.Minimum, T.Peak-Peak, T.σ, T.(σ/ Average), T.(P-P/Average), T.RF, and T.Number When in hardware histogram mode Statistical calculation parameters: Average, Maximum, Minimum, Peak-Peak, σ, σ/average, σ/t, Deviation, Deviation/T, Median, Mode, Number Auto Window Function Function Measures T. Value and automatically sets the size, scale, and area of each window according to the modulation type Modulation type EFM, EFM+, and 1-7 T. Value calculation method Measured T: Automatically sets the constant T value from the average value of the CH B clock input signal (T resolution: 25 ps) Estimated T: Estimates the constant T value from the input signal and modulation type. Operation Condition Measured T: CH B input 1025 cycles or more Estimated T: Data rate 80 MS/s or less, sampling time 1.6 s or less (when measuring pulse width or A-to-B time interval) Data rate 50 MS/s or less, sampling time 1.6 s or less (when measuring pulse width A & A-to-B time interval, pulse width A & pulse width B) T measurement range 7 ns to 250 ns Rear Panel Input/Output Reference input Connector type: BNC Input coupling: AC Input impedance: 1 kω or more Input frequency range: 10 MHz 10 Hz Input level: 1 V p-p or higher Maximum input voltage: 10 V 10-MHz output Connector type: BNC Output coupling: AC Output impedance: 50 Ω (typical value *1 ) Output frequency: 10 MHz (typical value *1 ) Output level *2 : 1 V p-p or higher Monitor output (CH A/CH B) Connector type: BNC Output impedance: 50 Ω (typical value *1 ) Output level *2 : Approx. 1/4 the input signal (5 V or less) Probe power terminal Number of output terminals: 2 (Usable probe: FET probe (700939)) Output voltage: 12 V Gate output Connector type: BNC Output level: TTL *1 Typical value represents a typical or average value. It is not strictly warranted. *2 Level when the input impedance on the receiving side is 50 Ω. 8
9 GP-IB Interface Interface GP-IB Electrical and mechanical Conforms to IEEE St d (JIS C ). specifications Mechanical specifications SH1, AH1, T6, L4, SR1, RL1 PP0, DC1, DT1, C0 Protocol Conforms to IEEE St d Code ISO (ASCII) code Mode Addressable mode Address 0 to 30 Clear remote mode Remote mode can be cleared using the LOCAL (SHIFT+AUTO SCALE) key (except during Local Lockout). Time Base Internal reference frequency Frequency stability External adjustment Temperature-compensated crystal oscillator, 10 MHz Aging rate: 1.5 ppm/year Temperature characteristics: 2.5 ppm in the range of 5 to 40 C with 25 C as the reference. Frequency accuracy at factory shipment: 0.5 ppm Possible Internal Memory Function 32 sets of setup parameters can be stored/recalled to/from the non-volatile memory Built-in Printer Printing system Dot density Paper width Printing width Thermal line dot system 8 dots/mm 112 mm 104 mm Built-in Floppy Disk Drive Drive type 3.5-inch floppy disk type Number of drives 1 Format type 720 KB or 1.44 MB (MS-DOS compatible) 9
10 PC Card Drive (Optional) Number of slots 1 Supported cards Flash ATA memory card (PC card TYPE II) Ethernet Communications (Optional) Communication port 1 Electrical and mechanical Conforms to IEEE802.3 specifications Transmission system Ethernet (10BASE-T) Transmission rate 10 M bps Communication protocol TCP/IP Supported services FTP server, FTP client (network drive), DHCP, DNS Connector type RJ-45 connector General Electrical and mechanical Ambient temperature: 23 5 C specifications Ambient humidity: 50 10% RH Supply voltage/frequency error: Within 1% of rating Operating altitude 2,000 m or less Warming up Approx. 30 minutes Storage conditions Temperature: 20 to 60 C Humidity: 20 to 80%RH (no condensation) Operating conditions Temperature: 5 to 40 C Humidity: 20 to 80%RH (no condensation) Rated supply voltage 100 to 120 VAC, 200 to 240 VAC Permitted supply voltage 90 to 132 VAC, 180 to 264 VAC range Rated supply voltage 50/60 Hz frequency Permitted supply voltage 48 to 63Hz frequency range Maximum power 250 VA consumption Withstanding voltage 1.5 kvac, 10 ma or less for one minute (between power supply and case) Insulation resistance 500 VDC, 10 MΩ or more (between power supply and case) Signal ground The ground of all input and output connectors is connected to the case ground. External dimensions Approx. 426 (W) 177 (H) 300 (D) mm (projections excluded) Weight Approx. 12 kg (main unit only) Cooling method Forced air cooling Installation position Horizontal (stacking prohibited) Battery backup Setup parameters and time are backed up using the internal lithium battery. Fuse *1 Maximum rated voltage: 250 V, maximum rated current: 3.15 A, type: time lag, standard: UL/VDE certified Part number: A1351EF Standard accessories Power cord (1), rubber feet (4), printer roll paper, user s manual (this manual) (1), communication interface user s manual (1) *1 There is also another fuse inside the unit, but the user cannot replace it. If you believe the fuse inside the unit is blown, contact your nearest YOKOGAWA dealer as listed on the back cover of this manual. 10
11 LOCAL AUTO SCALE INITIALIZE COPY MENU CH FILE SHIFT MHz sec/v/ ENTER 50 5Vrms 1M 40Vpk 1M 40Vpk 1Vp-p LINK TX External Dimensions Unit: mm Rear View GP-IB(IEEE488) MONITOR OUT 10MHz REF IN (50 ) (1Vp-p) CHA PROBE POWER ( 12V) REFERENCE ADJUST 10MHz OUT (1Vp-p) CHB ETHERNET 10BASE - T GATE OUT (TTL) WARNING V AC 250VA MAX 50/60Hz FUSE 250V T 3.15A Do not operate without reading safety precautions in user s manual MODE FUNCTION SAMPLE INPUT RESET SELSCT DISPLAY SCALE MARKER UTILITY COPY n m 0 SINGLE START/STOP ESC POWER CH A B EXT ARM/EXT GATE INHIBIT 20 If not specified, the tolerance is 3%. However, in cases of less than 10 mm, the tolerance is 0.3 mm. 11
Time Interval Analyzer
Time Interval Analyzer Yokogawa Electric Corporation 1st Edition Foreword Thank you for purchasing the YOKOGAWA TA320 Time Interval Analyzer. This user s manual contains useful information about the functions
More information15. Specifications WF1947/WF
15. Specifications 15.1 Oscillation Mode...15-2 15.2 Waveform...15-2 15.3 Frequency, Phase...15-3 15.4 Output Characteristics...15-3 15.5 Signal Characteristics...15-5 15.6 Modulated Oscillation Mode...15-7
More information4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points)
The values of items marked with *1 are guaranteed values. All other values are either nominal values or typical (typ.) values, and are not guaranteed. Conditions unless otherwise mentioned are as follows:
More informationDIGITAL STORAGE OSCILLOSCOPES
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE
More informationMG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz
Data Sheet MG3740A Analog Signal Generator 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Contents Definitions, Conditions of Specifications... 3 Frequency... 4 Output Level... 5 ATT Hold...
More informationArbitrary/Function Waveform Generators 4075B Series
Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationPM 6669 High-Precision Frequency Counter Specifications
PM 6669 High-Precision Frequency Counter Specifications Product Home Features Specifications Models, Options & Accessories Measuring functions Definitions Input specifications Auxiliary functions TimeBase
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationDual Channel Function/Arbitrary Waveform Generators 4050B Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationDIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES
756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,
More informationDIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX
756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is
More informationFREQUENCY SYNTHESIZERS, SIGNAL GENERATORS
SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And
More informationWaveStation Function/Arbitrary Waveform Generators
Function/Arbitrary Waveform Generators Key Features High performance with 14-bit waveform generation, up to 500 MS/s sample rate and up to 512 kpts memory 2 channels on all models Large color display for
More informationSpecifications DG1022 & DG1022A
Revised November, 2011 RIGOL Specifications DG1022 & DG1022A All the specifications apply to the DG1022/A Series Function/ Arbitrary Waveform Generator unless specified statement. To meet these specifications,
More informationDM3100V2 Specifications
DM3100V2 Specifications Analog input Number of slots 8-channel model: 4 (amplifier units can be intermixed) 16-channel model: 8 (amplifier units can be intermixed) Logic input Number of slots: 1 8 channels/unit
More informationSIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB
SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output
More informationDG5000 series Waveform Generators
DG5000 series Waveform Generators DG5000 is a multifunctional generator that combines many functions in one, including Function Generator, Arbitrary Waveform Generator, IQ Baseband /IQ IF, Frequency Hopping
More informationCharacteristics. Frequency (DG1022) Sine, Square, Ramp, Triangle, Pulse, Noise, Arb. ±50 ppm in 90 days ±100 ppm in 1year 18 C ~ 28 C.
Characteristics Frequency (DG1022) Waveforms Sine Square Ramp, Triangle Pulse Noise Arb Resolution Accuracy Temperature index Sine, Square, Ramp, Triangle, Pulse, Noise, Arb 1µHz ~ 20MHz 1µHz ~ 5MHz 1µHz
More informationDG4000 Series Waveform Generators
No.1 DG4000 DG4000 series is a multifunctional generator that combines many functions in one, including Function Generator, Arbitrary Waveform Generator, Pulse Generator, Harmonic Generator, Analog/Digital
More informationChapter 6 Specifications
RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,
More informationDual Channel Function/Arbitrary Waveform Generators 4050 Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationDIGITAL OSCILLOSCOPES & DIGITAL SCOPES
7004 Digital Oscilloscopes DL4100 (700430) 38 220 427mm 15kg ( 15-11/16 8-11/16 16-7/8" 33.1 lbs) YOKOGAWA introduces a brand new digital oscilloscope with outstanding performance. The DL4100 / DL4200
More informationContents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch
ZT530PCI & PXI Specifications Arbitrary Waveform Generator 16-bit, 400 MS/s, 2 Ch Contents Outputs... 2 Digital-to-Analog Converter (DAC)... 3 Internal DAC Clock... 3 Spectral Purity... 3 External DAC
More informationDigital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display
5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo
More informationDual Channel Function/Arbitrary Waveform Generators 4050 Series
Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary
More informationModel MHz Arbitrary Waveform Generator Specifications
50MHz Arbitrary Waveform Generator s DISPLAY: Graph mode for visual verification of signal settings. CAPABILITY: Standard waveforms: Sine, Square, Ramp, Triangle, Pulse, Noise, DC Built-in arbitrary waveforms:
More information10-CH, 100 ks/s Digitizer Module
User's Manual 10-CH, 100 ks/s Digitizer Module 3rd Edition 3rd Edition Thank you for purchasing the 10-CH, 100 ks/s Digitizer Module WE7251 for the PCbased measurement instruments, WE7000. This User s
More informationChapter 13 Specifications
RIGOL All the specifications can be guaranteed if the following two conditions are met unless where noted. The generator is within the calibration period and has performed self-calibration. The generator
More information7075 WAVEFORM GENERATOR SIGNAL SOURCE
2000 7075 WAVEFORM GENERATOR SIGNAL SOURCE Internal Sweep Sequence Functions Arbitrary Waveform Generator with Four Independently Controllable Channels The 7075 WAVEFORM GENERATOR includes both function
More informationRIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design
RIGOL Data Sheet DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Product Overview DG1000 series Dual-Channel Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationDG5000 Series Specifications
DG5000 Series Specifications All the specifications can be guaranteed if the following two conditions are met unless where noted. The generator is within the calibration period and has performed self-calibration.
More informationOSCILLOGRAPHIC RECORDERS
ORP00 / ORP300 & ORM00 / ORM300 780&780 Oscillographic Recorders ORP00 / ORP300 ORM00 / ORM300 * * ORM00 (780) 30 9 435mm 8.8kg (4-ch model) to 9.5kg (8-ch model) (-5/8 7-/6 7-3/6" 9.4 lbs (4ch model)
More informationData Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design
Data Sheet DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Product Overview DG1000 series Dual-Channel Function/Arbitrary Waveform Generators adopt Direct Digital Synthesis (DDS) technology,
More informationRIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.
RIGOL Data Sheet DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A Product Overview DG3000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationLT224/LT322/LT342/LT344/LT364 Technical Specifications
LT224/LT322/LT342/LT344/LT364 Technical Specifications Acquisition System Bandwidth (-3dB): LT322/LT342/LT344/LT364: 500 MHz @ 50 Ohm and at probe tip with PP006; select bandwidth limit (25 or 200 MHz)
More informationPM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator
PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator Technical Data Cal lab performance you can take anywhere Cal lab performance in the field The PM 6685 frequency counter
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
More informationGFT1504 4/8/10 channel Delay Generator
Features 4 independent Delay Channels (10 in option) 100 ps resolution (1ps in option) 25 ps RMS jitter (channel to channel) 10 second range Channel Output pulse 6 V/50 Ω, 3 ns rise time Independent control
More informationDS1000B Series Digital Oscilloscopes
Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial needs. The
More informationU1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes
United States Home >... > Oscilloscope Accessories > U1600 Series Oscilloscope Accessories > U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes Key Specifications Features Ni-MH Battery Pack,
More informationArbStudio Arbitrary Waveform Generators
ArbStudio Arbitrary Waveform Generators Key Features Outstanding performance with 16-bit, 1 GS/s sample rate and 2 Mpts/Ch 2 and 4 channel models Digital pattern generator PWM mode Sweep and burst modes
More informationChapter 5 Specifications
RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.
More informationDS1102E, DS1052E, DS1102D, DS1052D
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
More informationFunction/Arbitrary Waveform Generator
Distributed By: Signal Test, Inc 1529 Santiago Ridge Way San Diego, CA 92154 Tel. 1-619-575-1577 USA www.signaltestinc.com Sales@SignalTestInc.com DG1000ZSeries Function/Arbitrary Waveform Generator SiFi
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview The DS1000E, DS1000D series instruments are economical, high-performance digital oscilloscopes.
More information8558A 8 1/2 Digit Multimeter
8558A 8 1/2 Digit Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
More informationSpecifications for DS1000CA Series
Revised December, 2009 RIGOL Specifications for DS1000CA Series All specifications apply to the DS1000CA Series Oscilloscopes unless noted otherwise. To meet these specifications, two conditions must first
More information10-CH Digital Thermometer Module
User's Manual 10-CH Digital Thermometer Module 3rd Edition 3rd Edition Thank you for purchasing the 10-CH Digital Thermometer WE7241 for the PC-based measurement instruments, WE7000. This User s Manual
More information3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.
2004 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3
More informationChapter 6 Specifications
RIGOL This chapter describes the specifications of RF signal generator. Specifications are valid under the following conditions: the instrument in the calibration cycle is stored at least two hours at
More informationEach click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN
Each click of a dial opens a doorway to precision. Precision DC Calibrator Bulletin -01EN Yokogawa is a leader in providing high precision measurement equipment electric voltage/current, electric resistance,
More informationDIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS
Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback
More informationMODELS WW5061/2. 50MS/s Single/Dual Channel Arbitrary Waveform Generators
Single / Dual Channel 50MS/s waveform generator Sine waves to 25MHz, Square to 15MHz SINE OUT to 50MHz, 1Vp-p 11 Built-in popular standard waveforms 14 Bit amplitude resolution 11 digits frequency resolution
More information10 MHz Function Generator Module
User's Manual 10 MHz Function Generator Module 3rd Edition 3rd Edition Thank you for purchasing the 10 MHz Function Generator Module WE7121 for the PCbased measurement instruments, WE7000. This User s
More informationAnalog Arts SG985 SG884 SG834 SG814 Product Specifications [1]
www.analogarts.com Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, and an arbitrary
More information2.9GHz SPECTRUM ANALYZER
2.9GHz SPECTRUM ANALYZER Introducing a new 2.9GHz Spectrum Analyzer Manufacturing Research and Development Field Service Education Powerful capacity by advanced digital synthesizer Revolutionary features
More informationDIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES
Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The
More informationAnalog Arts SF900 SF650 SF610 Product Specifications
www.analogarts.com Analog Arts SF900 SF650 SF610 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without prior
More informationTektronix: Products > AWG 2040 Arbitrary Waveform Generator
Page 1 of 7 Arbitrary Waveform Generator AWG 2040 This product is no longer carried in our catalog. Features 1.024 GS/sec Clock Rate Provides up to 500 MHz Waveforms 1 MB Record Length (4 MB with Opt.
More informationDG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.
DG4000 Series Function/Arbitrary Waveform Generator Maximum output frequency: 200MHz, 160MHz, 100MHz, 60MHz 500MSa/s sample rate, 14 bit vertical resolution Dual channel outputs with identical performance
More informationU1604A Handheld Oscilloscopes, 40 MHz
Products & Services Technical Support Buy Industries About Agilent Search: All Test & Measurement Go United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1604A Handheld
More informationSDM3045X Digital Multimeter. DataSheet
SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for
More informationArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation
ArbStudio Arbitrary Waveform Generators Powerful, Versatile Waveform Creation UNMATCHED WAVEFORM UNMATCHED WAVEFORM GENERATION GENERATION Key Features 125 MHz bandwidth 1 GS/s maximum sample rate Long
More informationRIGOL Data Sheet. DG1022 Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design
RIGOL Data Sheet DG1022 Dual-Channel Function/Arbitrary Waveform Generator Product Overview DG1022 Dual-Channel Function/Arbitrary Waveform Generators adopt DDS technology, which enables to generate stable,
More informationn DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time
Specifications Unless otherwise specified, the measurement accuracy is guaranteed for one year under the following conditions: Temperature; 23±5 C, relative humidity; 85% or less (75% or less in resistance
More informationArbitrary/Function Generator AFG1000 Series Datasheet
Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab
More informationPhoton Counters SR430 5 ns multichannel scaler/averager
Photon Counters SR430 5 ns multichannel scaler/averager SR430 Multichannel Scaler/Averager 5 ns to 10 ms bin width Count rates up to 100 MHz 1k to 32k bins per record Built-in discriminator No interchannel
More informationAnalog Arts SF990 SF880 SF830 Product Specifications
1 www.analogarts.com Analog Arts SF990 SF880 SF830 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without
More informationkhz to 2.9 GHz Spectrum Analyzer
Spectrum Analyzers 2399 9 khz to 2.9 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements. 9 khz to 2.9 GHz
More informationAnalog Arts SL987 SL957 SL937 SL917 Product Specifications [1]
www.analogarts.com Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, an arbitrary
More information1 GS/s Digital Oscilloscope Module
User's Manual 1 GS/s Digital Oscilloscope Module 1st Edition 1st Edition Thank you for purchasing the 1 GS/s Digital Oscilloscope Module WE7311 for the PCbased measurement instruments, WE7000. This User
More information2-channel models. 4-channel models
2-channel models DSO1052B DSO1072B DSO1102B DSO1152B 50 MHz 70 MHz 100 MHz 150 MHz 4-channel models DSO1004A DSO1014A DSO1024A 60 MHz 100 MHz 200 MHz DSO1022A 200 MHz Segment 1 Segment 2 Segment 1000
More informationChapter 5 : Specifications
Chapter 5 : Specifications All specifications apply to the DS1000B Series Oscilloscopes and a probe with the Attenuation switch set to 10X unless noted otherwise. To meet these specifications, two conditions
More informationApplications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source
Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom SMARTWAVE Programmable AC/DC Power Source PRODUCT OVERVIEW of cycles for each segment, the user can
More informationPQube 3 Specifications
PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,
More informationDSA700 Series Spectrum Analyzer
DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.
More informationBipolar Output Working Standard
6166 DC Voltage/Current Source 6½-digit working standard suitable for calibration High-accuracy and highly stable with bipolar output l Wide dynamic range and high resolution Voltage source: ±10nV to ±1200V
More informationWR300 SERIES. Direct Recording Chart, Internal Memory, 40GB HDD. Multi-Function Voltage / Temperature / Strain / Frequency
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Thermal Arraycorders WR300 SERIES State of the art recorder! Accurate Data capture
More informationCIRCUIT-TEST ELECTRONICS
USER'S MANUAL Sweep Function Generator with Counter SWF-8030 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY INFORMATION...page 3 INTRODUCTION... 4 SPECIFICATIONS... 5 FRONT PANEL
More informationAgilent N9343C Handheld Spectrum Analyzer (HSA)
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Agilent N9343C Handheld Spectrum Analyzer (HSA) 1 MHz to 13.6 GHz (tunable to 9 khz) Data Sheet Field
More informationDIGITAL HiTESTER 3237, 3238, 3239
DIGITAL HiTESTER,, 3239 4-terminal Ω function Advanced model Economically priced 3239 Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed 5 1 /2 digit DMM The DIGITAL
More informationWide-band Models from DC to 100 MHz
CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available
More informationWT3000 Manual, Vol 3/3 WT3000. Precision Power Analyzer Expansion Function. IM E 7th Edition
WT3000 Manual, Vol 3/3 WT3000 Precision Power Analyzer Expansion Function 7th Edition Thank you for purchasing the WT3000 Precision Power Analyzer. This Expansion Function User s Manual contains useful
More informationPXIe Contents. Required Software CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5160 This document contains the verification and adjustment procedures for the PXIe-5160. Refer to ni.com/calibration for more information about calibration solutions. Contents
More informationSpecifications. Specifications and Characteristics Specifications
Specifications and Specifications Specifications All specifications are warranted. Specifications are valid after a 30-minute warm-up period and ±5 C from last calibration temperature. Bandwidth (-3dB)
More informationData Sheet. Function/Arbitrary Waveform Generator. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform
Data Sheet Function/Arbitrary Waveform Generator DDS technology, dual-channel output 125MSa/s sample rate, 14bit vertical resolution. 5 types of standard output, built-in 46 arbitrary s(include DC) Complete
More informationMaximum output frequency:160 MHz, 100 MHz, 60 MHz 500MSa/s sample rate, 14 bits vertical resolution Dual Channel Outputs With Identical Performance
Maximum output frequency:160 MHz, 100 MHz, 60 MHz 500MSa/s sample rate, 14 bits vertical resolution Dual Channel Outputs With Identical Performance 2ppm High-frequency Stability -115dBc/Hz Low Phase Noise
More informationThe specifications apply when the function generator is powered on for at least 30 minutes under 18 C~28 C.
The specifications apply when the function generator is powered on for at least 30 minutes under 18 C~28 C. CH1 Function With ARB MFG-2000 series specific functions CH2 RF 25MHz Function With Generator
More informationSL1400. ScopeCorder LITE. IM E 1st Edition
SL400 ScopeCorder LITE IM 7040-0E st Edition Foreword Thank you for purchasing the SL400 ScopeCorder LITE. The purpose of this operation guide is to familiarize the first-time user with the basic operations
More informationWR300 SERIES. Direct Recording. Multi-Function. Direct Operation. Easy PC Connection. Thermal Arraycorders
Thermal Arraycorders WR300 SERIES State of the art recorder! Accurate Data capture and recording. This machine has it all. Direct Recording Chart, Internal Memory, 40GB HDD Multi-Function Voltage / Temperature
More informationAgilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.
Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set Data Sheet Definitions All specifications apply over a 5 C to 40 C range
More informationR&S SMB100N SIGNAL GENERATOR
R&S SMB100N SIGNAL GENERATOR PERFORMANCE SPECIFICATIONS VERSION 02.00, SEPTEMBER 2009 CONTENTS Specifications...3 Definitions... 3 RF performance... 4 Frequency... 4 Frequency sweep... 4 Reference frequency...
More informationFunction/Arbitrary Waveform Generator
DG1000ZSeries Function/Arbitrary Waveform Generator Innovative SiFi (Signal Fidelity): generate arb waveform point-by-point, restore signal distortionless, precisely adjustable sample rate and low jitter
More informationR3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation
R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World
More informationModel 6517B Electrometer / High Resistance Meter Specifications
VOLTS Accuracy (1 Year) 1 / C 2V 10µV 0.025+4 0.003+2 20V 100µV 0.025+3 0.002+1 200V 1mV 0.06+3 0.002+1 NMRR: 2V and 20V range > 60dB, 200V range > 55dB. 50Hz or 60Hz 2 CMRR: >120dB at DC, 50Hz or 60Hz.
More informationDigital Multimeters R6871E/R6871E-DC. R6871E/R6871E-DC Digital Multimeters. High-Speed and Low-Price DMM with a Sampling Rate of 2,000 Times/Second
High-Speed and Low-Price DMM with a Sampling Rate of 2,000 Times/Second R6871E/R6871E-DC R6871E: Low-price and High-Grade Model with Five Basic Functions R6871E-DC: Low-Price Model Focusing on DC Voltage
More informationWider vertical range (500 uv/div~10 V/div), lower noise floor, better for small signal capturing. Built-in dual-channel 25 MHz source (MSO/DS2000A-S)
Wider vertical range (500 uv/div~10 V/div), lower noise floor, better for small signal capturing Built-in dual-channel 25 MHz source (MSO/DS2000A-S) UltraVision: deeper memory (analog channel up to 14
More informationDA FREQUENCY RESPONSE ANALYZER FRA5097. Specification. NF Corporation
DA00014286-004 FREQUENCY RESPONSE ANALYZER FRA5097 Specification NF Corporation Table of Contents Page 1. Introduction 1 1.1 Overview 1 1.2 Features 2 1.3 Application 3 2. Accessories 4 3. Specifications
More informationDATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM
DATA SHEET 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Features Fast reading speed of up to 190 readings/sec 0.015% DCV accuracy Multiple connectivity options USB 2.0, Serial Interface (RS-232)
More information