Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

Size: px
Start display at page:

Download "Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE"

Transcription

1 JUST IN TIME with the New Generation NGG from Schleicher NGG CATALOGUE

2 General information on the New Generation NGG Quality control 2 Norms, regulations, approvals 2 Housing system, conductor sizes 3 Ergonomics and control 4 Multi-voltage 4 Environmental protection 4 Time ranges 5 Time setting 5 Remote control 6 Function setting 6 Excitation input 6 Displays and controls 7 Features 8 Relay comparison list 9 NGZP 72-S ON-delay multi-range time relay 52 Single-range mono-function devices NGD 3 Star-delta relay 54 NGD 32 Star-delta relay 56 NGW Signal-watchdog relay 58 NGY 3 Interval ON single-range relay 60 NGY 32-S Interval ON single-range relay 62 NGYP 32-S Interval ON single-range relay 64 NGZ ON-delay single-range time relay 66 NGZ 2 ON-delay single-range time relay 68 NGZ 2-S ON-delay single-range time relay 70 NGZ 0 OFF-delay single-range time relay 72 NGZ 30 OFF-delay single-range time relay 74 NGZ 320 OFF-delay single-range time relay 76 NGZP 3 ON-delay single-range time relay 78 NGZP 32 ON-delay single-range time relay 80 NGZP 32-S ON-delay single-range time relay 82 Alphabetical list 0 Type overview Function modes and function code descriptions 2 Mono-function devices with fixed range NGB Fixed time flasher relay 84 NGB 2 Fixed time flasher relay 86 NGF 3 Notching relay 88 NGF 32 Notching relay 90 NGF 52 Notching relay 92 NGY Interval ON relay 94 NGY 52 Interval ON relay 96 Multi-range multi-function devices NGM NGM NGM NGM NGMP Multi-range mono-function devices NGY 7 Interval ON multi-range relay 32 NGY 72-S Interval ON multi-range relay 34 NGYP 72-S Interval ON multi-range relay 36 NGZ 7 ON-delay multi-range time relay 38 NGZ 72 ON-delay multi-range time relay 40 NGZ 72-S ON-delay multi-range time relay 42 NGZ 70 OFF-delay multi-range time relay 44 NGZ 720 OFF-delay multi-range time relay 46 NGZP 7 ON-delay multi-range time relay 48 NGZP 72 ON-delay multi-range time relay 50 Accessories Remote Potentiometer FP 0 k 98 Tables (recovery times) Table 99 Table 2 99 Table 3 99 Table 4 00 Table 5 00 General technical specifications 0 Terms of sale and delivery 04

3 SCHLEICHER relays have repeatedly set international standards, not only on miniaturization and style Switching relays with time response have traditionally been associated with the name of SCHLEICHER SCHLEICHER relays have always been designed for the global market So they naturally meet all the European and international standards Our decades of success are also based on the reliable quality of SCHLEICHER products Not only has the company been meeting the ISO 900 requirements for years now, but our quality management also includes automatic in-circuit tests and active burn-in tests THE SWITCHING DEVICE PIONEER Norms, Regulations, Approvals All important national and international standards were taken into consideration during the New Generation NGG development process UL and CSA have been applied for The New Generation NGG meets the following norms: EN 682-: "Relays with defined time response (time relays for industrial applications)" IEC 6000 "Electromagnetic Compatibility" IEC ; DIN VDE 0660 Part 200 "Low Voltage Switching Devices" IEC "Protection Type IEC "Environmental Conditions" 2

4 PRESENTS THE FUTURE OF TIME RELAYS SCHLEICHER has put the all the skill and competence of decades of switching device manufacture into developing a completely new timer generation for all applications with state-of-the-art microprocessor technology at an extremely attractive price, using environmentally friendly materials to economize on resources Integrated concept with 225 mm housing width 6 switchable time ranges from 005 s to 300 h Multi-voltage relays - AC/DC 24 V to 240 V Multi-function relays with up to 6 functions Attractive prices through efficient rationalized manufacturing systems New Housing System The New Generation NGG has a uniform housing width of 225 mm Depending on the number of changeover contacts, the function and the remote potentiometer connection, the housing height and depth is either 83 x 98 mm or 94 x23 mm Depending on the housing type, the devices have 69 or 2 screw-type box terminals with captive Pozidrive screws The 30 mm Pozidrive-2 screws on the box terminals are designed for torque up to Nm to allow use of automatic screwdrivers The housing is made of light grey polycarbonate (PC) with flammability class V0 acc to UL 94 Conductor sizes with stripping length 9 mm: x 02 to 6 mm 2 x 04 to 4 mm 2 x 05 to 25 mm 2 2x 02 to 25 mm 2 2x 02 to 5 mm 2 (single-core or finely stranded) (stranded with wire-end ferrule) (stranded with twin wire-end ferrule) (single-core or finely stranded) (stranded with wire-end ferrule) 3

5 Ergonomics is a Must The New Generation NGG is characterized by clear front design and labelling, and is designed for any installation position All functions and time ranges are operated via large, easy to set analog scales on the front of the relay All controls are flush with the relay front, to prevent accidental adjustment Some versions also offer a fast setting feature for time ranges/functions on the righthand side of the housing The devices can be clipped onto standard DIN rails (35 mm, EN 50222) and removed again absolutely simply without tools s show the state of the excitation input and the position of the contacts You can monitor the countdown on a flashing An Eye to the Environment Multi-voltage The New Generation NGG is designed for DC and AC from 24 V to 240 V and 50 to 60 Hz SCHLEICHER cares about the environment We select environmentally compatible materials and methods Cadmium-free relay contacts Electrolytic capacitors without ammonium compounds Recyclable design, halogen-free polycarbonate housing Lettering by laser rather than solvent-based printing 4

6 Time Ranges on Multi-Range Time Relays The following 6 ranges allow you to set times from 0 s to 300 h: Time Ranges on Single-Range Time Relays The following 3 setting ranges are available: 0 to s 05 to 3 s 05 to 0 s 5 to 30 s 5 to 00 s 5 to 300 s 50 to 000 s 0,5 to 0 min 5 to 30 min 3 to 60 min 5 to 00 min 05 to 3 h 05 to 0 h 5 to 30 h 5 to 00 h 5 to 300 h 0 to s 05 to 3 s 05 to 0 s 5 to 30 s 5 to 00 s 5 to 300 s 50 to 000 s 05 to 0 min 5 to 30 min 3 to 60 min 05 to 0 h 5 to 30 h 5 to 00 h Time setting On multi-range time relays the time range is set with the RANGE selector switch and displayed in the window next to it The precise delay time is set by turning the time setting wheel Note: You can change the delay time during operation but the change is effective immediately in this case Example: To set a delay time of 5 s set the RANGE selector switch to time range 30 s and the time setting wheel to 05 (= 50 % of maximum value) This sets a delay time of 5 s The time range can be set particularly easily before installation, using a screwdriver to turn the RANGE selector switch on the right-hand side of the device After installation the RANGE selector switch can only be adjusted in single steps from the front Mounting Removal The devices can be clipped onto standard DIN rails and removed again absolutely simply without tools 5

7 Remote Control? You can also connect an optional remote control potentiometer to set parameters at a distance and to make time setting easier when devices are installed in enclosures Note: When a remote potentiometer is used, set the time setting wheel on the device to the right-hand stop above the largest value Operation without remote potentiometer does not require a jumper on the relay Function setting Excitation Input The rated voltage of the excitation input (B-) may differ from the device voltage (A-) The function is set with the MODE selector switch and displayed by the function code in the window next to it The code designations of the 34 available functions are listed on page 2 ff The function can be set particularly easily before installation, using a screwdriver to turn the MODE selector switch on the right-hand side of the device After installation the MODE selector switch can only be adjusted in single steps from the front Note: You must not change the function during operation because the change would be effective immediately 6

8 2 Displays and Controls on New Generation NGG Relays C A 3 4 B 2 6, 9 or 2 box terminals Space for lettering RANGE selector switch with 6 setting ranges A B Single-step setting Fast setting C A B 7 C RANGE window 4 displays 5 Time setting wheel 6 Laser-drawn function diagram on side 7 MODE selector switch with 6 functions A Single-step setting B C Fast setting MODE window 7

9 Features of the New Generation NGG Multi-range multi-function devices 6 or 0 functions 6 Time ranges from 0 s to 300 h or 2 changeover contacts (2nd changeover contact can be set as instantaneous changeover contact (depending on function)) Multi-voltage relays from and 50 to 60 Hz Remote potentiometer connection (NGMP 00) 2 or 3 s for function display Multi-range mono-function devices function 6 Time ranges from 0 s to 300 h or 2 changeover contacts Multi-voltage relays from and 50 to 60 Hz Remote potentiometer connection (NGZP 7, NGZP 72, NGZP 72 - S) 2 s for function display Single-range mono-function devices function time range (3 different time ranges from 0 s to 00 h are available) or 2 changeover contacts Multi-voltage relays from and 50 to 60 Hz Remote potentiometer connection (NGYP 32 - S, NGZP 3, NGZP 32, NGZP 32 - S) 2 s for function display Mono-function devices with fixed time function fixed time 05 s or 2 changeover contacts Multi-voltage relays from and 50 to 60 Hz 2 s for function display 8 9

10 Comparison List for the New Generation NGG Relays Previous relay type in the K series Type in the New Generation NGG Previous relay type in the S series Type in the New Generation NGG KSB NGB KSD 3 NGD 3 KSD 32 NGD 32 KSY NGY KSY 3 NGY 3 KSY 7 NGY 7 KZT NGZ KZT 0 NGZ 0 KZT 2 NGZ 2 KZT 2 - S NGZ 2 - S KZT 3 NGZP 3 KZT 30 NGZ 30 KZT 5 NGM 002 KZT 7 NGZ 7 KZT 70 NGZ 70 KZT 9 NGM 004 NGMP 00 New NGF 3 New NGF 32 New NGF 52 New NGM 002 New NGM 003 New NGM 004 New NGM 600 New NGW New NGY 72 - S New NGYP 32 - S New NGYP 72 - S New NGZP 7 SSB 2 NGB 2 SSB 22 NGB 2 SSY 32 - S NGYP 32 - S SSY 42 - S NGYP 32 - S SSY 52 NGY 52 SZT 2 NGZ 2 SZT 0 NGZ 0 SZT 3 NGZP 3 SZT 32 NGZP 32 SZT 32 - S NGZP 32 - S SZT 320 NGZ 320 SZT 4 NGZP 3 SZT 42 NGZP 32 SZT 42 - S NGZP 32 - S SZT 420 NGZ 320 SZT 72 NGZ 72 NGZP 72 SZT 72 M NGZP 72 SZT 72 - S NGZ 72 - S NGZP 72 - S SZT 72 - SM NGZP 72 - S SZT 720 NGZ 720 SZT 82 NGZP 72 SZT 82 - S NGZP 72 - S SZT 820 NGZ 720 SZT 92 - SM NGM 600 SZT 92 M NGM 600 The types marked blue (NGM 600) are multi-range multi-function devices The types with a blue P in the designation are designed for remote potentiometer connection The New Generation NGG devices are largely compatible in function and connection with SCHLEICHER K- and S-series time relays 2 9

11 Alphabetic List of New Generation NGG Types Relay type Page NGB 84 NGB 2 86 NGD 3 54 NGD NGF 3 88 NGF NGF NGM NGM NGM NGM NGMP NGW 58 NGY 94 NGY 3 60 NGY 32-S 62 NGY NGY 7 32 NGY 72-S 34 NGYP 32-S 64 NGYP 72-S 36 NGZ 66 NGZ 2 68 NGZ 2-S 70 NGZ 7 38 NGZ NGZ 72-S 42 NGZ 0 72 NGZ NGZ NGZ NGZ NGZP 3 78 NGZP NGZP 32-S 82 NGZP 7 48 NGZP NGZP 72-S 52 The types marked blue (NGM 600) are multi-range multi-function devices The types with a blue P in the designation are designed for remote potentiometer connection 0 3

12 2 Type Overview catalogue page Version Multi-function Mono-function Multi-range Single range Fixed time Remote potentiometer connection Function code ON-delay - ON ON-delay B ON-delay C ON-delay C - ON ON-delay 2 OFF-delay 2 - ON OFF-delay - 2 ON-delay + OFF-delay 2-22 OFF-delay + interval OFF 3 OFF-delay 4 Signal watchdog 2 interval ON 2 - ON interval ON 2-22 interval ON + interval OFF 22 interval OFF 22 - ON interval OFF 23 interval ON + interval OFF 4 clock-generating, starts OFF 42 clock-generating, starts ON 43 clock-generating, starts OFF clock-generating, starts OFF + ON 44 clock-generating, starts ON NGM 600 NGM 004 NGM 003 NGM 002 NGMP 00 NGY 7 NGY 72-S NGYP 72-S NGZ 7 NGZ 72 NGZ 72-S NGZ 70 NGZ 720 NGZP 7 NGZP 72 NGZP 72-S NGD 3 NGD 32 NGW X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X NGY 3 NGY 32-S NGYP 32-S NGZ NGZ 2 NGZ 2-S NGZ 0 NGZ 30 NGZ 320 NGZP 3 NGZP 32 NGZP 32-S NGB NGB 2 NGF 3 NGF 32 NGF 52 NGY NGY 52 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Type Overview of the New Generation (NGG) 5 star-delta 52 star-delta X X X X X 8 - X s ON-delay 8 - Xs - ON ON-delay 8C - X s ON-delay 82 pulse-shaping 82 - ON pulse-shaping 83 - X s pulse-generating X s pulse-generating 84 X s pulse-generating 98 notching 99 notching Contact equipment Changeover contacts XX X X X XX X X X X X X X X X X X X X

13 Function Modes for the New Generation NGG ON-Delay Time Relay Time relay where the timing period starts when the energizing quantity (A - ) is switched on and the timed changeover contacts switch to operated condition after the preselected delay time t A Function code ON-delay t A A - 5-8, Function code - ON ON-delay ON-Delay Time Relay Time relay where the timing period starts and the instantaneous changeover contact switches to operated condition when the energizing quantity (A - ) is switched on and the timed changeover contact switches to operated condition after the preselected delay time t A When the energizing quantity switch is switched off the instantaneous and the timed changeover contact switch to normal condition t A A ON-Delay Two-Wire Relay Time relay where the timing period starts when the energizing quantity (A - ) is switched on and the binary contact () switches to operated condition after the preselected delay time t A Function code B ON-delay t A A - ON-Delay Time Relay, Accumulative Yes/No with Auxiliary Supply Time relay where the timing period starts when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The timed changeover contact switches to operated condition after the preselected time t A Time accumulation: timing period t A starts when the energizing quantity (B - ) and the auxiliary supply (A - ) are switched on Switching off the energizing quantity interrupts the timing period and the individual intervals (t A + t + t An = t A ) are added until the preselected timing period t A has been reached When the energizing quantity or the auxiliary supply is interrupted the changeover contact switches to normal condition Function code C ON-delay, accumulative yes/no, with auxiliary supply t A t A t A - B t A = t A + t ON-Delay Time Relay, Accumulative Yes/No with Auxiliary Supply and Instantaneous Contact Time relay where the instantaneous changeover contact switches to operated condition and the timing period starts when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The timed changeover contact switches to operated condition after the preselected time t A Time accumulation: timing period t A starts and the instantaneous changeover contact switches to operated condition when the energizing quantity (B - ) and the auxiliary supply (A - ) are switched on Switching off the energizing quantity interrupts the timing period and the individual intervals (t A + t + t An = t A ) are added until the preselected timing period t A has been reached Then the timed changeover contact switches to operated condition When the energizing quantity or the auxiliary supply is interrupted both changeover contacts switch to normal condition Function code C - ON ON-delay, accumulative yes/no, with auxiliary supply t A t A t A - B t A = t A + t 2

14 Function code 2 OFF-delay with auxiliary supply OFF-Delay Time Relay with Auxiliary Supply Time relay where the timed changeover contacts switch immediately to operated condition when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The timing period starts when the energizing quantity is switched off and after the preselected delay time t R the timed changeover contacts switch to normal condition The timed changeover contacts switch to normal condition immediately when the auxiliary supply (A - ) is switched off t R A - B - 5-8, OFF-Delay Time Relay with Auxiliary Supply Time relay where the timed changeover contact switches immediately to operated condition when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The timing period starts when the energizing quantity is switched off and after the preselected delay time t R the timed changeover contact switches to normal condition The instantaneous changeover contact switches in the rhythm of the energizing quantity The timed and instantaneous changeover contacts switch to normal condition immediately when the auxiliary supply (A - ) is switched off Function code 2 - ON OFF-delay with auxiliary supply t R <t R A - B ON/OFF-Delay Time Relay with Auxiliary Supply Time relay where the second timed changeover contact switches immediately to operated condition and timing period t A starts when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The first timed changeover contact switches to operated condition after the preselected delay time t A has been reached The first timed changeover contact is reset to normal condition and timing period t R starts when the energizing quantity is switched off and after the preselected delay time t R the second timed changeover contact switches to normal condition The timed changeover contacts switch to normal condition immediately when the auxiliary supply (A - ) is switched off Function code - 2 ON-delay, OFF-delay with auxiliary supply t A t R A - B Function code 2-22 OFF-delay and interval OFF, 05 s fixed interval time, with auxiliary supply OFF-Delay and Interval OFF Time Relay with Auxiliary Supply Time relay where the first timed changeover contact switches immediately to operated condition when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The timing period starts when the energizing quantity is switched off and after the preselected delay time t R the first timed changeover contact is reset to normal condition and the second timed changeover contact switches to operated condition for the duration of interval time t WA The timed changeover contacts switch to normal condition immediately when the auxiliary supply (A - ) is switched off t R t WA A - B

15 Function code 3 OFF-delay without auxiliary supply OFF-Delay Time Relay without Auxiliary Supply Time relay where the timed changeover contact switches immediately to operated condition when the energizing quantity (A - ) is switched on The timing period starts when the energizing quantity is switched off and after the preselected delay time tr the timed changeover contacts are reset to normal condition t R A - 5-8, Signal Watchdog with Auxiliary Supply Time relay where the timed changeover contact switches immediately to operated condition and the timing period starts when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on The countdown restarts each time the energizing quantity is switched off and on during the delay time If the break or make time of the energizing quantity is longer than the delay time t, the timed changeover contact switches to normal condition When the energizing quantity is switched on again after the countdown the timed changeover contact remains in normal condition The timed changeover contact switches to normal condition immediately when the auxiliary supply (A - ) is switched off Function code 4 signal-watchdog with auxiliary supply A - < t < t < t t B Interval ON Relay Time relay where the interval changeover contacts switch immediately to operated condition when the energizing quantity (A - ) is switched on, and are reset to normal condition after the set interval t WE The interval changeover contacts switch to normal condition immediately when the energizing quantity is switched off during the interval time Function code 2 interval ON t WE A - 5-8, Interval ON Relay Time relay where the interval changeover contact and the instantaneous changeover contact switch immediately to operated condition when the energizing quantity (A - ) is switched on, and the interval changeover contact is reset to normal condition after the set interval t WE When the energizing quantity switches off the instantaneous changeover contact switches to normal condition The timed and instantaneous changeover contacts switch to normal condition immediately when the energizing quantity is switched off during the interval time Function code 2-ON interval ON t WE < t WE A

16 Interval ON/OFF Relay with Auxiliary Supply Time relay where the first interval changeover contact switches immediately to operated condition when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on, and the changeover contact is reset to normal condition after the set interval t WE When the energizing quantity is switched off, the second interval changeover contact switches immediately to operated condition, returning to normal condition after the set interval t WA The interval changeover contacts switch to normal condition immediately if, during the interval time, the energizing quantity is switched off or on or the auxiliary supply (A - ) is switched off Function code 2-22 interval ON, interval OFF, with auxiliary supply t WE t WA A - B Interval OFF Relay with Auxiliary Supply Time relay where the interval changeover contact switches immediately to operated condition when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched off, and is reset to normal condition after the set interval t WA The interval changeover contact switches to normal condition immediately if, during the interval time, the energizing quantity is switched on or the auxiliary supply (A - ) is switched off Function code 22 interval OFF, with auxiliary supply t WA A - B Interval OFF Relay with Auxiliary Supply Time relay where, when the auxiliary supply (A - ) is on, the instantaneous changeover contact switches to operated condition when the energizing quantity (B - ) is switched on and to normal condition when the energizing quantity is switched off When the energizing quantity is switched off, the interval changeover contact switches immediately to operated condition, returning to normal condition after the set interval t WA The instantaneous or interval changeover contact switches to normal condition immediately if, during the interval time, the energizing quantity is switched on or the auxiliary supply (A - ) is switched off Function code 22 - ON interval OFF, with auxiliary supply t WA A - B Interval ON/OFF Relay Time relay where the interval changeover contact switches immediately to operated condition when the energizing quantity (A - ) is switched on, and is reset to normal condition after the fixed interval t WE (bridge Z - Z2) If Z2 - Z3 is bridged, when the energizing quantity is switched off, the interval changeover contact switches immediately to operated condition, returning to normal condition after the fixed interval t WA If there is no bridge, when the energizing quantity is switched on or off the interval changeover contact switches to operated condition for the fixed interval t WE /t WA Funktionscode 23 interval ON / OFF twe t WE t WA t WE t WA Z - Z2 Z2 - Z3 A Function code 4 flashing, starts OFF Symmetrical Flasher Relay, Starts OFF Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is connected, whereby the ON time t I and OFF time t P are equal and fixed t P t I t P t I t P A - 5-8,

17 Symmetrical Clock Generator, Starts OFF Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is connected, whereby the ON time t I and OFF time t P are equal and settable Function code 4 clock-generating, starts OFF t P t I t P t I t P A - 5-8, Symmetrical Clock Generator, Starts ON Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is connected, whereby the ON time t I and OFF time t P are equal and settable Function code 42 clock-generating, starts ON t I t P t I t P t I A Function code 43 clock-generating, 05 s fixed OFF and ON time, OFF start, with cycle time setting range Symmetrical Clock Generator, Starts OFF, with Cycle Time Setting Range Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is connected, until the preselected cycle time setting range t B is reached The output starts OFF ON time ti and OFF time tp are equal and fixed (05 s) t P t I t B A Function code clock-generating, 05 s fixed OFF and ON time, OFF/ON start, with cycle time setting range Symmetrical Clock Generator, Starts OFF/ON, with Cycle Time Setting Range Time relay, whose two timed changeover contacts switch on and off periodically when the energizing quantity (A - ) is connected, until the preselected cycle time setting range t B is reached The first timed changeover contact starts OFF, the second timed changeover contact starts ON ON time ti and OFF time tp are equal and fixed (05 s) The two timed changeover contacts operate synchronously in push-pull mode t P t I t I t P t B A Function code 44 clock-generating, 05 s fixed OFF and ON time, ON start, with cycle time setting range Symmetrical Clock Generator, Starts ON, with Cycle Time Setting Range Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is connected, until the preselected cycle time setting range tb is reached The output starts ON ON time t I and OFF time t P are equal and fixed (05 s) t I t P t B A

18 Function code 5 star-delta switching, interval ON Star-Delta Relay, Interval ON Time relay with two sequentially switching delayed outputs for starting motors in star-delta mode After expiry of the preselected acceleration time t H for star mode and a fixed transit time t U the second contact switches to operated condition for delta mode When the energizing quantity (A - ) switches off the contact switches to normal condition t H t U A Function code 52 star-delta switching, 2-fold ON-delay Star-Delta Relay, ON-Delay Time relay with two sequentially switching delayed outputs for starting motors in star-delta mode When the energizing quantity (A - ) is connected the preset delay time (acceleration time t H ) starts for star mode When this time is reached the changeover contact switches to operated condition and the fixed transit time t U runs Then the second changeover contact switches to operated condition for delta mode When the energizing quantity switches off both changeover contacts switch to normal condition t H t U A Function code 8 - X s ON-delay, pulse-generating, X s fixed ON time ON-Delay Time Relay with Pulse Output Time relay where the timing period starts when the energizing quantity (A - ) is switched on When the preselected delay time t A is reached the timed changeover contact switches to operated condition for a fixed (X s) interval t I t A t I A Function code 8 - X s - ON ON-delay, pulse-generating, X s fixed ON time ON-Delay Time Relay with Pulse Output Time relay where the timing period starts and the instantaneous changeover contact switches to operated condition when the energizing quantity (A - ) is switched on When the preselected delay time t A is reached the timed changeover contact switches to operated condition for a fixed (X s) interval t I t A t I A

19 ON-Delay Time Relay, Accumulative Yes/No with Auxiliary Supply and Pulse Output The timing period starts when the auxiliary supply (A - ) is on and the energizing quantity (B - ) is switched on When the preselected time t A is reached the timed changeover contact switches to operated condition for a fixed (X s) interval t I Time accumulation: timing period t A starts when the energizing quantity (B - ) and the auxiliary supply (A - ) are switched on Switching off the energizing quantity interrupts the timing period and the individual intervals (t A + t + t An = t A ) are added until the preselected timing period t A has been reached Then the timed changeover contact switches to operated condition for a fixed (X s) interval t I When the energizing quantity or the auxiliary supply is interrupted the changeover contact switches to normal condition Function code 8C - X s ON-delay, accumulative yes/no, pulse-generating, X s fixed ON time, with auxiliary supply ta t I t I ta t I t t t A3 t I I A - B Function code 82 pulse-shaping, with auxiliary supply Pulse Shaper (Interval ON) with Auxiliary Supply Time relay where, when the auxiliary supply (A - ) is on, the pulse changeover contact switches immediately to operated condition when the energizing quantity (B - ) is switched on and returns to normal condition when the preset pulse time t I has expired This is independent of the time for which the energizing quantity is switched on The pulse changeover contact switches to normal condition immediately when the auxiliary supply (A - ) is switched off t I A - B Function code 82 - ON pulse-shaping, with auxiliary supply Pulse Shaper (Interval ON) with Auxiliary Supply Time relay where, when the auxiliary supply (A - ) is on, the instantaneous and pulse changeover contacts switch immediately to operated condition when the energizing quantity (B - ) is switched on and the pulse changeover contact returns to normal condition when the preset pulse time t I has expired This is independent of the time for which the energizing quantity is switched on When the energizing quantity switches off the instantaneous changeover contact switches to normal condition The instantaneous and pulse changeover contacts switch to normal condition immediately when the auxiliary supply (A - ) is switched off t I A - B Function code 83 - X s pulse-generating, X s fixed ON time, starts OFF Clock Generator, Starts OFF Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is on, whereby the OFF time t P is settable and the ON time t I is fixed t P t I A

20 Function code X s pulse-generating, X s fixed ON/OFF time Clock Generator, Starts ON/OFF Time relay, whose two timed changeover contacts switch on and off periodically when the energizing quantity (A - ) is on On the first timed changeover contact the OFF time t P is settable and the ON time t I is fixed while on the second timed changeover contact the ON time t I is settable and the OFF time t P is fixed The two timed changeover contacts operate synchronously in pushpull mode t P t I t I t P A Function code 84 - X s pulse-generating, starts ON, X s fixed OFF time Pulse Clock Generator, Starts ON Time relay, whose timed changeover contact switches on and off periodically when the energizing quantity (A - ) is on ON time t I is settable and OFF time t P is fixed t I t P A Function code 98 notching ON-OFF, with auxiliary supply Notching Relay with Auxiliary Supply Relay where, after the auxiliary supply (A - ) has been switched on, the changeover contact switches to operated condition with the rising edge of the energizing quantity (B - ) and switches to normal condition with the next edge of the energizing quantity This occurs alternately when the energizing quantity is switched on When the auxiliary supply (A - ) is switched off the changeover contact switches to normal condition A - B - - 4, 2-24 Function code 99 notching ON-OFF/OFF-ON, with auxiliary supply Notching Relay with Auxiliary Supply Relay with two changeover contacts where, after the auxiliary supply (A - ) has been switched on, the notching relay switches the first changeover contact to operated condition with the rising edge of the energizing quantity (B - ) With the next rising edge the first changeover contact switches to normal condition and the second to operated condition This occurs alternately when the energizing quantity is switched on When the auxiliary supply (A - ) is switched off the changeover contacts switch to normal condition A - B

21 L A L+ 5 A B /2 3 28/24 26/22 NGM /2 RANGE 300 s TIME EW2 _ MODE 26/22 28/24 LBL+ 8 N M NGM 600 Multi-function multi-range time relay Multi-voltage for 6 function Setting range from 0 s to 300 h divided into 6 switchable time ranges 2 changeover contacts or instantaneous changeover contact and one timed changeover contact (function-dependent) 3 s for function display Function code = ON-delay t A t Function code - ON = ON-delay t A t < t A t 2 t A FD t A = Operating time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Functions < t A FD t A = Operating time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 t 2 t A A- Energizing quantity 5-6 green Delayed contact green A- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green Setting range from 0 s to 300 h divided into: < 0 to s 5 to 30 min 05 to 3 s 3 to 60 min 05 to 0 s 5 to 00 min 5 to 30 s 05 to 3 h 5 to 00 s 05 to 0 h 5 to 300 s 5 to 30 h 05 to 0 min 5 to 00 h 50 to 000 s 5 to 300 h A N L L+ B M NGM 600 Price code: 20 Time ranges Connection diagram A 5 25 (2) B (22) (24) Dimensions KS K Ordering designation Features Setting the Function The function is set with the MODE selector switch and displayed by the function code in the window next to it The code designation for the function can be found in the "Functions" column Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it The required delay time is set with a setting wheel s show the state of the excitation input and the position of the contacts You can monitor the countdown on a flashing Note The device is designed for multi-voltage Connect phase L or L + to terminal A and B and neutral N and/or M to terminal You can change the function or the delay time during operation The change is effective immediately Function code C- ON = ON-delay, accumulative y/n, with auxiliary supply t A I t t A t 2 t t 2 t A3 I A- Auxiliary supply B - Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green FD t A = Operating time t = Break time, must be > recovery time n t 2 = Break time, must be > recovery time 2 ta = tax IB- Function code 2 = OFF-delay, with auxiliary supply t 3 t t R t 4 t < t R t 2 < t R FD t R = Returning time t = Make time, must be > minimum ON time t 2 = Make time, must be > minimum ON time 2 t 3 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time t 4 = Break time, must be > recovery time 2 Function code 2 - ON = OFF-delay, with auxiliary supply t 3 t t R t 4 t < t R t 2 < t R FD t R = Returning time t = Make time, must be > minimum ON time t 2 = Make time, must be > minimum ON time 2 t 3 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time t 4 = Break time, must be > recovery time 2 Function code - 2 = ON-delay, OFF-delay, with auxiliary supply t 3 t A < t A t t R t < t R 2 FD t A = Operating time t R = Returning time t = Make time, must be > recovery time t 2 = Make time, must be > minimum ON time t 3 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time 2 I A- Auxiliary supply B - Energizing quantity 5-6 green Delayed contact green A- Auxiliary supply B - Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green A- Auxiliary supply B - Energizing quantity 5-6 green Delayed contact green 20 /99

22 Functions Technical data Function code 2-22 = OFF-delay and interval OFF, 05 s fixed interval time, with auxiliary supply t WA t 2 t t R t3 t <t R t t R < t WA FD t R = Returning time t WA = Fixed interval OFF time t = Make time, must be > minimum ON time t 2 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time t 3 = Break time, must be > recovery time 2 Function code 2 = interval ON t WE t < t WE t 2 t WE FD t WE = Interval ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Function code 2 - ON = interval ON t WE t < t WE t 2 t WE FD t WE = Interval ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Function code 2-22 = interval ON, interval OFF, with auxiliary supply t WE t WA t WE t t 2 t WE = Interval ON time t WA = Interval OFF time t = Break time, must be > recovery time t2 = Make time, must be > minimum ON time < t WE < t WA < t WA FD A- Auxiliary supply B - Energizing quantity 5-6 green Delayed contact green A- Energizing quantity 5-6 green Delayed contact green A- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green A- Auxiliary supply B- Energizing quantity 5-6 green Delayed contact green Function code 22 - ON = interval OFF, with auxiliary supply t t WA t 2 < t WA t < t WA FD t WA = Interval OFF time t = Make time, must be > minimum ON time t 2 = Make time, must be > minimum ON time 2 A- Auxiliary supply B- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green Function code = clock-generating, 05 s fixed OFF and ON time, OFF/ON start, with cycle time setting t P t I t P t I <t P t t P t I t I t P t I t P <t I t t I tp Function code 5 = star-delta switching, interval ON t I <tp t 2 A- Energizing quantity 5-6 green Delayed contact green t B < tb t B t B = Cycle time t I = tp FD t P = Fixed OFF time t = Break time, must be > recovery time t I = Fixed ON time t 2 = Break time, must be > recovery time 2 t H t U t P <t I t 2 t P t I A- Energizing quantity 5-8 Delayed contact 5-6 green Delayed contact green Device type Product norm (Time relays) Relay function according to IEC (445) Function diagram Function display Ambient operating temperature range Input circuit Rated voltage A -, B - Rated power AC Rated power DC Rated voltage limits Rated frequency fn Release value of input voltage (line capacitance approx 50 pf/m) Rated current on control connection (B - ) Rated power on control connection (B - ) Parallel load permitted Internal one-way rectifier Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time /2/3 Minimum ON time /2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) Output circuit Contact equipment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Utilization category according to IEC Permissible switching frequency Mechanical service life Electrical service life 20/2 A, AC 250 V, cos ϕ = 03 Operate time / release time for excitation A - Operate time / release time for excitation B - Other data Clearance/creepage distances to IEC Contamination level Overvoltage category Rated voltage Protection class housing / terminals acc to IEC Interference immunity acc to IEC Dimensions (housing) Terminal connection diagram Weight General technical data NGM 600 EN : Multi-function relay with multi-time-range See "Functions" column 3 s green - 25 to + 60 C 35 VA/7 W 6 W 70 to 0 % 50 to 60 Hz ± 5 % AC/DC 0 V; permissible line capacitance 02 µf ma < 025 W A - yes/b - yes A - no/b - yes analog/6 from 0 s to 300 h divided into: 0 to s 5 to 30 min 05 to 3 s 3 to 60 min 05 to 0 s 5 to 00 min 5 to 30 s 05 to 3 h 5 to 00 s 05 to 0 h 5 to 300 s 5 to 30 h 05 to 0 min 5 to 00 h 50 to 000 s 5 to 300 h See table See table ± 5 % ± 00 % + ± 0 ms ± 0002 % ± 0002 % 2 changeover contacts AgNi 90/0 5 A AC/DC 5 V/ 0 ma AC 5 U e AC 230 V, I e 3 A DC 3 U e DC 24 V, I e 2 A 3600 switching cycles/h 30 x 06 switching cycles 02 x 06 switching cycles AC 5 40 ms 20 ms 3 outside, 2 inside III AC/DC 275 V IP 40/IP 20 Test level 3 K 3-3 KS kg Page 09 t H = acceleration time FD t U = Transit time 00 ms /3 2

23 Functions Function code 8 - s - ON = ON-delay, pulse-generating, s fixed ON time t A t I t <t A t 2 t A t I FD t A = Operating time t I = Fixed ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 A- Energizing quantity 5-6 green Function code 8 - s - ON 2-24 Instantaneous contact 2-22 green Function code 82 - ON = pulse-shaping, with auxiliary supply t3 t t I t 2 t I t 2 <t I A- Auxiliary supply B- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green FD t I = Fixed ON time t = Make time, must be > minimum ON time t 2 = Break time, must be > recovery time t 3 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time 2 Function code s = pulse-generating, s fixed ON or OFF time t P t I t P t I t t P t I t I t P t I t P t t I t P t P FD t P = OFF time t I = ON time t = Break time, must be > recovery time t I A- Energizing quantity 5-6 green Delayed contact green Legend Control signal for energizing quantity Settable time Fixed time Settable cycletime green excitation 5-fold function Energizing quantity ON Delayed contact in operated condition Delayed contact in normal condition Delayed contact in normal or operated condition Energizing quantity OFF 22 /99

24 /3 23

25 L A L+ B L 5 A B RANGE 000 s TIME MODE NGM N M NGM 004 Multi-function multi-range time relay Multi-voltage for 0 functions Setting range from 0 s to 300 h divided into 6 switchable time ranges changeover contact 2 s for function display Time ranges Setting range from 0 s to 300 h divided into: < 0 to s 5 to 30 min 05 to 3 s 3 to 60 min 05 to 0 s 5 to 00 min 5 to 30 s 05 to 3 h 5 to 00 s 05 to 0 h 5 to 300 s 5 to 30 h 05 to 0 min 5 to 00 h 50 to 000 s 5 to 300 h Connection diagram A L L+ A B 5 B 5 Features Setting the Function The function is set with the MODE selector switch and displayed by the function code in the window next to it The code designation for the function can be found in the "Functions" column Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it The required delay time is set with a setting wheel s show the state of the excitation input and the position of the contacts You can monitor the countdown on a flashing Function code = ON-delay, also immediate operation t A t < t A t 2 < t A t S FD t A = Operating time t S = Immediate signal, must be > minimum ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 A- Energizing quantity B - Function code C = ON-delay, accumulative y/n, with auxiliary supply Function code 2 = ON-delay, also immediate release t WE t A Functions I t t A t 2 t t 2 ta3 t < t WE t 2 < t WE t S FD t WE = Interval ON time t S = Immediate signal, must be > minimum ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Immediate signal 5-6 green A- Auxiliary supply B - FD t A = Operating time t = Break time, must be > recovery time n t 2 = Break time, must be > recovery time 2 t A = tax I B- Function code 2 = OFF-delay, with auxiliary supply t 3 t t R t 2 t < t R t < t R I I Energizing quantity 5-6 green A- Auxiliary supply B - Energizing quantity 5-6 green FD t R = Returning time t = Make time, must be > minimum ON time t 2 = Break time, must be > recovery time 2 t 3 = Time between switching on auxiliary supply and energizing quantity, must be > recovery time A- Energizing quantity B- Immediate signal 5-6 green 225 N M Dimensions KS Note The device is designed for multi-voltage Connect phase L or L + to terminal A and B and neutral N and/or M to terminal You can change the function or the delay time during operation The change is effective immediately Function code 22 = interval OFF, with auxiliary supply t t WA t 2 < t WA t < t WA FD t WA = Interval OFF time t = Make time, must be > minimum ON time t 2 = Make time, must be > minimum ON time 2 Function code 44 = clock-generating, 05 s fixed ON and OFF time, ON start, with cycle time setting range, also immediate release t I t P t I t P <t I t t I tp A- Energizing quantity B - Immediate signal 5-6 green t B <t B t B = Cycle time t I = t P FD t I = Fixed ON time t S = Immediate signal, must be > minimum ON time t P = Fixed OFF time t = Break time, must be > recovery time t S A- Auxiliary supply B - Energizing quantity 5-6 green K 3- Ordering designation NGM 004 Price code: /99

26 Functions Technical data Function code 8C - s = ON-delay, accumulative y/n, pulse-generating, s fixed ON time, with auxiliary supply t2 t A t I t I ta t I t t t A3 t I A- Auxiliary supply B - Energizing quantity 5-6 green FD ta = Operating time t = Break time, must be > recovery time n t 2 = Time between switching on auxiliary supply and t A = tax energizing quantity, must be > recovery time 2 I B- t I =Fixed ON time Function code 8C -2 s = ON-delay, accumulative y/n, pulse-generating, 2 s fixed ON time, with auxiliary supply t2 t A t I t I ta t I t t t A3 t I I A- Auxiliary supply B - Energizing quantity 5-6 green FD t A = Operating time t = Break time, must be > recovery time n t 2 = Time between switching on auxiliary supply and energizing tax t A = quantity, must be > recovery time 2 I B- t I = Fixed ON time Function code 82 = pulse-shaping, with auxiliary supply t3 t t I t2 t I t2 <t I I A- Auxiliary supply B- Energizing quantity 5-6 green FD t I = ON time t = Make time, must be > minimum ON time t 2 = Break time, must be > recovery time t 3 = Time between switching on auxiliary supply and Energizing quantity, must be > recovery time 2 Function code 83 - s = pulse-generating, s fixed ON time, OFF start, also immediate pulse generation t P t S t I t P t I t P t IS tp2 t I <t P t Device type Product norm (Time relays) Relay function according to IEC (445) Function diagram Function display Ambient operating temperature range Input circuit Rated voltage A -, B - Rated power AC Rated power DC Rated voltage limits Rated frequency fn Release value of input voltage (line capacitance approx 50 pf/m) Rated current on control connection (B - ) Rated power on control connection (B - ) Parallel load permitted Internal one-way rectifier Time circuit Time setting / number of time ranges Setting ranges for time delay Recovery time /2/3 Minimum ON time /2 Setting tolerance Repeatability (to set value) Influence of temperature (within range) Influence of voltage (within range) NGM 004 EN : Multi-function relay with multi-time-range See "Functions" column 2 s green - 25 to + 60 C 35 VA/7 W 6 W 70 to 0 % 50 to 60 Hz ± 5 % AC/DC 0 V; permissible line capacitance 02 µf ma < 025 W A - yes/b - yes A - no/b - yes analog/6 from 0 s to 300 h divided into: 0 to s 5 to 30 min 05 to 3 s 3 to 60 min 05 to 0 s 5 to 00 min 5 to 30 s 05 to 3 h 5 to 00 s 05 to 0 h 5 to 300 s 5 to 30 h 05 to 0 min 5 to 00 h 50 to 000 s 5 to 300 h See table 2 See table 2 ± 5 % ± 00 % + ± 0 ms ± 0002 % ± 0002 % t t P t S t I t P >t IS t I < tp < 2 s t P FD A- Energizing quantity B- Immediate signal 5-6 green t P = OFF time t S = Immediate signal, must be > minimum ON time t P ----= t P + t P2 t = Break time, must be > recovery time t I = Fixed ON time t IS = Fixed immediate pulse time Legend t S <t I Control signal for Energizing quantity Settable time Fixed time Output circuit Contact equipment Contact material Rated operating voltage Rated value for limiting continuous current Ith Minimum contact load Utilization category according to IEC Permissible switching frequency Mechanical service life Electrical service life 20/2 A, AC 250 V, cos ϕ = 03 Operate time / release time for excitation A - Operate time / release time for excitation B - changeover contacts AgNi 90/0 5 A AC/DC 5 V/ 0 ma AC 5 U e AC 230 V, I e 3 A DC 3 U e DC 24 V, I e 2 A 3600 switching cycles/h 30 x 06 switching cycles 02 x 06 switching cycles AC 5 40 ms 20 ms green excitation Settable cycletime 5-fold function Energizing quantity ON Delayed contact in operated condition Delayed contact in normal condition Delayed contact in normal or operated condition Energizing quantity OFF Other data Clearance/creepage distances to IEC Contamination level Overvoltage category Rated voltage Protection class housing / terminals acc to IEC Interference immunity acc to IEC Dimensions (housing) Terminal connection diagram Weight General technical data 3 outside, 2 inside III AC/DC 275 V IP 40/IP 20 Test level 3 K 3 - KS kg Page 09 /3 25

27 L A L /2 3 28/24 26/22 NGM /2 RANGE 300 s TIME /22 28/24 2-ON MODE 8 N M NGM 003 Multi-function multi-range time relay Multi-voltage for 0 function Setting range from 0 s to 300 h divided into 6 switchable time ranges 2 changeover contacts or instantaneous changeover contact and one timed changeover contact (function-dependent) 3 s for function display Function code = ON-delay t A t < t A FD t A = Operating time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Function code - ON = ON-delay FD t A = Operating time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 t 2 t A t A t < t A t 2 t A Functions A- Energizing quantity 5-6 green Delayed contact green A- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green Time ranges Setting range from 0 s to 300 h divided into: < 0 to s 5 to 30 min 05 to 3 s 3 to 60 min 05 to 0 s 5 to 00 min 5 to 30 s 05 to 3 h 5 to 00 s 05 to 0 h 5 to 300 s 5 to 30 h 05 to 0 min 5 to 00 h 50 to 000 s 5 to 300 h Connection diagram Features Setting the Function The function is set with the MODE selector switch and displayed by the function code in the window next to it The code designation for the function can be found in the "Functions" column Setting the time delay The time range is set with the RANGE selector switch and displayed in the window next to it The required delay time is set with a setting wheel Function code 2 = interval ON t WE t < t WE t 2 t WE FD t WE = Interval ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Function code 2 - ON = interval ON t WE t < t WE t 2 t WE FD t WE = Interval ON time t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 A- Energizing quantity 5-6 green Delayed contact green A- Energizing quantity 5-6 green 2-24 Instantaneous contact 2-22 green A L L+ A 5 25 (2) 5 25 s show the state of the excitation input and the position of the contacts You can monitor the countdown on a flashing Function code 4 = clock-generating, starts OFF t P t I t P <t I t t P t I <tp t 2 t P A- Energizing quantity 5-6 green Delayed contact green 755 N M (22) (24) Dimensions KS Note The device is designed for multi-voltage Connect phase L or L + to terminal A and neutral N or M to terminal You can change the function or the delay time during operation The change is effective immediately FD t P = OFF time t I = ON time t P = t I t = Break time, must be > recovery time t 2 = Break time, must be > recovery time 2 Function code = clock-generating, 05 s fixed OFF and ON time, starts OFF and ON, with cycle time setting range t P t I t P t I <t P t t P t I t I t P t I t P <t I t t I tp t P <t I t 2 t P t I <tp t 2 A- Energizing quantity 5-6 green Delayed contact green t B < tb t B t B = Cycle time t I = t P FD t P = Fixed OFF time t = Break time, must be > recovery time t I = Fixed ON time t 2 = Break time, must be > recovery time 2 t I Function code 5 = Star-delta switching, interval ON K 3-3 Ordering designation t H t H = acceleration time t U FD t U = Transit time 00 ms A- Energizing quantity 5-8 Delayed contact 5-6 green Delayed contact green NGM 003 Price code: /99

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Electronic timers CT-S range Selection and ordering details

Electronic timers CT-S range Selection and ordering details CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges

More information

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.

More information

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)

More information

83 SERIES. 83 Series - Modular timers A. Features

83 SERIES. 83 Series - Modular timers A. Features Features 83 Series - Modular timers 12-16 A 83.01 83.02 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24... P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Phase sequence and phase failure monitor

Phase sequence and phase failure monitor Measuring and monitoring relay Measuring and monitoring relay Current and voltage monitor Detection of falling below and exceeding a set threshold value of voltages and currents Phase sequence and phase

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Electronic relays. Monitoring. Monitoring

Electronic relays. Monitoring. Monitoring Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal 83 Modular timers 12-16 A 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous options), external time setting

More information

Multi-function 11 pin Plug-in for use with 90 series sockets

Multi-function 11 pin Plug-in for use with 90 series sockets 88 88 Multi-voltage and multi-function timer range Front panel or socket mount 8 and 11 pin plug-in versions available Time scales from 0.05 s to 100 h 1 delayed contact +1 instantaneous contact version

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004 Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay

More information

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions

More information

PIR6WT-1Z interface - time relays

PIR6WT-1Z interface - time relays 1 9-functions electronic time relays compliance with standard PN-EN 612-1 Time relay PIR6WT-1Z consists of: - universal socket with electronic PI6WT-1Z with screw terminals, - changeover relay RM699V,

More information

Modular timers A

Modular timers A Modular timers 1-6 - 8-16 A Building automation Elevators and lifts 80 SЕRIES Automation for blinds, grilles and shutters oists and cranes Panels for electrical distribution Door and gate openers FINDER

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

22/10/2012

22/10/2012 22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

RENF22R2MMW Zelio Timer Relay - Modular

RENF22R2MMW Zelio Timer Relay - Modular Characteristics Zelio Timer Relay - Modular Main Range of product Product or component type Device short name Operating system Software version Software designation Complementary Discrete output type Nominal

More information

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A SNO 4062K Basic unit for emergency stop and guard door applications Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring. PL e and category 4 as per

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 62.00 USD Main Range of product Product

More information

Multi-voltage Multi-function. Wiring diagram (without control signal)

Multi-voltage Multi-function. Wiring diagram (without control signal) 80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of

More information

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC Overview/Product Selection Bulletin 700-FS Adjustable Function and Timing Range DIN Rail Mounted without Cost of Socket 22.5 mm Wide Multifunction or Single Functions Available as SPDT or DPDT Contact,

More information

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17LLBM asymmetrical flashing relay s V AC - solid state output Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Product availability : Stock - Normally stocked in distribution facility Price* : 86.00 USD Main Range of product Product

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Current monitor Type C 551

Current monitor Type C 551 Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and

More information

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type Characteristics universal plug-in timing relay - 110..240 V AC - 1 C/O Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition Component

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Electronic timer CT-SDE

Electronic timer CT-SDE CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.

More information

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O Product datasheet Characteristics RE22R2MYMR Multi-function Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal

More information

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC Characteristics adjustable symmetrical flashing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 202.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component

More information

Miniature Power Relay MSR

Miniature Power Relay MSR V23061 PCB relay for DC voltage, neutral, monostable Features Used as a switching element for electrical separation between low-power control circuits and power load circuits With 8 mm clearance and creepage

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New) XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information