(4,7mm).187 DIA (4) CONTROLLER SUPPLY VOLTAGE : 115 volts _+ 10%, 50/60 Hz., 4 V.A. maximum 230 volts + 100, 50/60 Hz., also available.
|
|
- Emery Beasley
- 5 years ago
- Views:
Transcription
1 DATA SHEET MODEL O (4,7mm).187 (4,7mm).187 DIA (4) SPECIFICATIONS : CONTROLLER SUPPLY VOLTAGE : 115 volts _+ 10%, 50/60 Hz., 4 V.A. maximum 230 volts + 100, 50/60 Hz., also available. CONTROLLER OUTPUT : Isolated zero cross-over solid state switch rated at 10 amps maximum, 0.5 amps minimum. HEATER SUPPLY VOLTAGE : This will vary depending upon application. Power bridge must be designed, for the application. The supply voltage for the heater an be the same as is used for the controller. Hcwever, the heater can be operated fr3m a separate source from 24 to 230 volts A.C., 50/60 Hz. HEATER TEMPERATURE RESISTANCE CHARACTERISTICS : The proper heater material and selection depends upon the application. Consult factory ' for information. Page 1 of 13 11IUAYNCO INC. W'NONA. MINNESOTA FAST EIGHTH STREET PHONE
2 DATA SHEET-~,.=-I-')"~='-."-- MODEL. 4t- SPECIFICATIONS : SET POINT RANGE : Set point is adjustable by a remote connected potentiometer. The range of adjustments are selected for the application. Heaters are available for operation up to 2000 F. CYCLE TIME : The sampling rate is adjustable over a range of 1 to 5 seconds minimum. OPERATING AMBEINT TEMPERATURE : 50 F to 125 F. LED INDICATOR : A red LED indicator lamp on the terminal board indicates the operational status of the controller. The LED is on when the controller is applying power to the heater. EXTERNAL WIRING DIAGRAM : ~TFOS 1(I1(1 10,11 IFS101(0 I S CYCLE 1(11(1 il0( 01 Temperature Set Pot I l. C I[Ii(1 11s,1.C rxlilfl~ -SOKII-1 L : t, ID L2 Heater 115 VAC, 50/60 Hz. 24 to 230 VAC Page 2 of 13 WAYNCO INC. WINONA, MINNESOTA EAST EIGHTH STREET PHONE
3 DATA SHEET ;)_- ;-_-,-' MODEL -azzz=9 APPLICATION OF HEAT-SENSE CONTROL r~~~ -~ ~t Y-OJ ;J ; The Model heat-sense temperature controller utilizes the principle of change in resistance of the heater with temperature to provide the feedback signal to the controller to maintain a constant temperature of the heater. In other words, the resistance heater supplies the thermal requirements of the system as well as the feedback signal for control. The response time is essentially instantaneous since the heater cannot change temperature without a corresponding change in resistance. In a conventional temperature control system the feedback signal is obtained by means of a separate sensor such as a thermocouple, thermistor, RTD, etc. Normally, the heater used in a conventional system maintains a relatively constant resistance over a wide range of temperatures. The response time in a conventional system depends upon the thermal time constant between the heater and sensor. Both systems have obvious advantages. The choice depends upon the control application. In some applications superior results can be obtained by a combination of both systems. There are other types available to suit various applications. This bulletin covers only one type of heat-sense controller. The key to successful application of the heat-sense technique is to satisfy the thermal requirements of the system before choosing a particular heat-sense control or designing the power bridge. A temperature control system utilizing the heat-sense principle consists of a resistance heater, power bridge, electronic controller package and solid state power relay or switch. Since the heater'supplies the thermal requirements as well as the feedback signal, a power bridge is required. Fig. 1 illustrates the basic heat-sense power bridge. Fig. 1 The heater and shunt resistor form one arm of the bridge and the set pot and associated resistors form the opposite arm of the bridge. The voltage (el) Page 3 of 13 &4 WIN ONA MINNESOTA EAST EIGHTH STREET PHONE
4
5 D~`;TA SHEET M03EL TEMP2RATURE CONTROLLER BRIDGE BOARD ASS'Y. The following is a list of discrete ccmpcnents needed to make up this Bridge Board Assembly. Use as listed or equivalent. RESISTORS : Qty : 1 ea. R1, R2, R5, R6 Waynco P/N : %, 1/2W Manufacturer : IRC (TO-60) Standard 1% resistance values available. r1.sminj -+jo(r.15d1a MAX 00 SCHEMATIC SYMBOL TRIM POTS : Qty : l. ea. R3, R4 Waynco P/N : turn Manufacturer : Bourns (3006P) Standard resistance values needed : lk, 2K, 5K, 10K, 20K ohm i 2s F+--.76MAX+{ ~~4.06 ~- LEADS WILL FIT A.04 DIA HOLE.20 2 WIPER CLOCKWISE SHUNT RESISTOR : Qty. 1 ea. Waynco P/N : %, 5W Manufacturer : Dale (LVR-5) Resistance values needed :.025,.05,.10,.25,.50 ohms r 2.00 r W ~F SCHEMATIC SYMBOL.04 DIA W1NONA, MINNESOTA SCHEMATIC SYMBOL 1265 EAST EIGHTH STREET Page 5 of 13 PHONE
6 DATA SHEET MODEL -2 ~ TERMINALS FOR SHUNT RESISTOR : Qty. 2 ea. -~ P/N : o0 Manufacturer : VACO (11208) DIA FOR NO.8 SCREW ~-~ ~-.14 D1A --r~ ~--DIA FOR NO.18 THRU 22 GA.WIRE REMOTE SET POT : Qty. 1 ea. 77Lo W P/N : ,3,c) Manufacturer : Clarostat (Series 43 H.T.) Standard resistance values : 25, 100, 200, 250, 500, 1K ohms SCHEMATIC SYMBOL WINONA, MINNESOTA Page 6 of EAST EIGHTH STREET PHONE
7 D E N T I A L PROCEDURE FOR POWER BRIDGE DATA SHEET MODEL l. The value of the following parameters must be determined prior to design of the bridge circuit. a) Line Voltage, E L b) Resistance of the heater at room temperature, 72 F c) Resistance of the heater at the low end of the temperature range, R HL d) Resistance of the heater at the high end of the temperature range, RHH 2. The maximum value of the shunt resistor RS MAX. i s now calculated. Its value should be the maximum allowable by the following two constraints : a) The maximum power dissipation rating of the shunt resistor, PS MAX. b) The maximum input voltage of the temperature control, 0.6 volts. < PS MAX. < 0.6 VOLTS I 72 F = EL RS MAX. and RS MAX., where 72 F)2 72 F 72 F The value of the shunt resistor is now selected. 3. The current through the heater at the low (IHL) and high (IHH) end of the temperature range is now calculated. 4. The voltage across the shunt resistor at the low (E SL ) and high (E SH ) end of the temperature range can now b~ calculated. ESL I HL RS, E SH I HH RS The change in the voltage across the shunt resistor, is needed to determine the value of the set pot. h ES = ESL ESH 5. The total power dissipated by the resistors in the bridge circuit should be limited to approximately 0.6 watts to avoid changes in the resistance due to the temperature coefficient of the resistors. Therefore for operation on 120V line, the bridge current should be approximately amps and on 240V line :005 amps. The currents for other line voltages can be calculated from the equation : I = 1.2 NOTE! Power Dissipation = RMS (Power), since bridge circuit is EL 2 half wave. Page 7 of 13 WINONA, MINNESOTA EAST EIGHTH STREET PHONE
8 C O N F I D E N T I A L DATA SHEET 1 -=> = -=~~' " ~'= J MODEL 6. The approximate value of the set pot can now be calculated from : Rp = 10 AES The closest standard value pot is chosen, Rp S. The current through the pot, IRP, is calculated using the selected standard pot value with the equation : IRP = 10 AES RpS 7. To provide for calibration of the set pot at the low end of the temperature range, R4 and R5 are connected in parallel with the set pot. These resistors provide +20% calibration adjustment. The value of R5 is determined by : R5 = 10 A ES.2 IRP R4 is selected to have a minimum value 20 times RPS. 8. The value of R6 is now determined from the equation : R6 = 10 ESN IRP +.2 (IRp) 9. The total resistance of the bridge circuit is determined next. RTOTAL = EL IRp `.2 I RP) From RTOTAL, the values of Rl, R2 and R3 can be calculated. Rl + R2 + R3 = RTOTAL - RD-R6 For + 20,o adjustment a- the high temperature end of the temperature range, R3 should be made.4 (RTOTAL - Rp - R6) and Rl + R2 = RTOTAL - Rp - R6 - R3 Rl and R2 are made equal in value to divide the power dissipation. Therefore, Rl = RTOTAL - rp - R6 - R3 2 = R2 2 The calculation of the bridge resistors is now complete. WAYNCO INC. Page 8 of 13 WINONA MINNESOTA EAST EIGHTH STREET PHONE
9 C O N F I D E N T I A L DATA SHEET ! 7_O::) :, MODEL DESIGN EXAMPLE 1. a), Line Voltage, EL = 240VAC b) 72 F = 20 ohms = 27 ohms d) RHH = 55 ohms F = 240VAC = 12 amperes 20 ohms PS MAX. = 5 watts RS MAX. < 5 watts 12 amps 2 <.034 ohms RS MAX. < 0.6 volts 12.amps <.050 ohms A shunt resistor of.025 ohms, 5 watts is selected. 3. IHL = 240 volts IHH = 240 volts 27 ohms = 8.88 amps 55 ohms 4.36 amps 4. ESL = (8.88 amp) (.025 ohms) _.222 volts ESH = (4.36 amps) (.025 ohms) _.109 volts A ES =.222 volts volts =.113 volts 5. 1 = 1.2 = 1.2 =.005 amps EL Rp = (10 ) (.113) = 226 ohms.005 The closest standard value pot is 250 ohms. IRP = (10) (.113) = amps R4 = (10) (.113) = 1250 ohms R5 = (20) (250) = 5K ohms -C.2( ) 8. R6 = (10) (.109) ohms (.00452) + (.2) (.00452) Page 9 of 13 ea4, WINONA MINNESOTA EAST EIGHTH STREET PHONE
10 C 0 N F I D E N T I A L DATA SHEET MODEL 9. RTOT = 240 = 44,247 ohms ( R3 = 44, = 43,797 R3 = (.4) (43,797) = 17,519 closest pot value is 25K ohms. Rl + R2 = 43,797-25,000 = 31,297 2 Rl = 31,297 = 15,648 = R2 2 R1, R2 = 15.4K ohms. (B Page 10 of 13 WINONA MINNESOTA EAST EIGHTH STREET PHONE
11 DATA SHEET MODEL SYSTEM CALIBRATION PROCEDURE system may be calibrated by utilizing a temperature sensor such as a thermistor, thermocouple, etc. attached to the heater surface in combination with a suitable temperature indicator. Following is the recommended procedure : 1. Make all connections to the temperature control system. CAUTION : Check all connections for mechanical and electrical integrity. Never energize the system with the shunt disconnected as the controller may be permanently damaged. 2. Turn the temperature set pot, low temperature adjust and high temperature adjust to their minimum temperature settings counter clockwise). Turn the cycle time adjust to its maximum counter clockwise direction. Supply power to the controller only. 3. With the heater supply voltage disconnected and the cycle time pot maximum counter clockwise, the LED should remain off. Slowly turn the cycle time pot in a clockwise direction until the LED turns on. The LED should remain on. Connect the heater supply voltage. The LED will begin to cycle on-off when the heater reaches temperature. This will be the minimum temperature at which the heater can be operated. 4. Turn the temperature set pot to its maximum temperature setting. 5. Adjust the high temperature pot to obtain the desired maximum temperature of the surface to be controlled as indicated by the temperature monitor. 6. Turn the temperature set pot to its minimum temperature setting. 7. Adjust the low temperature pot to obtain the desired minimum temperature of the surface to be controlled as indicated by the temperature monitor. 8. Repeat steps 4 through 7. Re-adjust the high and low temperature pots if necessary. 9. Turn the set pot to the desired operating temperature. 10. Decrease the cycle time if the temperature is fluctuating to obtain minimum change in temperature. NOTE : Decreasing the cycle time will increase the minimum obtainable temperature. C5 Page 11 of 13 WINONA MINNESOTA EAST EIGHTH STREET PHONE
12 DATA SHEET 22o J- ^,- MODEL TROUBLE ANALYSIS AND SERVICE CHART SYMPTOM CAUSE REMEDY Over Heats Shorted Solid State Connect jumper wire across Switch shunt resistor. If power turns off, switch okay. If not, replace control. Over Heats Controller Indicator If solid state switch from Light OFF above test okay, replace controller. Over Heats Controller Indicator Check inter-connecting Light ON. wire to terminals. If connections per connection diagram and system continues to over heat, replace controller. Power On Heater Heater Open Replace Heater. Also But Not Heat check wiring and all connections. Pulses ON-OFF Improper Calibration Repeat Calibration But Temp. Below Procedure. Set Point Pulses ON-OFF High Resistance Check heater resistance But Temp. Below connection in heater and all connections. Set Point circuit. Pulses ON-OFF Bridge Board not Tighten all screws on But Temp. Below screwed down Bridge Board Set Point - tightly. Pulses ON-OFF Set Pot. leads Pl Check wiring of remote Temp. Below Set and P3 reversed. Set Pot. Point Page 12 of 13 WINONA, MINNESOTA EAST EIGHTH STREET PHONE
13 DATA SHEET MODEL-&2=_ b TROUBLE ANALYSIS AND SERVICE CHART SYMPTOM CAUSE REMEDY Pulse ON-OFF Temp. Be'l ow Set Point. Bad Controller Replace Controller. Unit does not pulse Heater Power. Indicator light on, controller is off. Improper adjustment, cycle rate adj. Turn Clockwise until indicator light comes on. If unable to attain this condition, replace controller. Unit does not pulse Heater Power and Indicator Light On. Improper wiring. Indicates broken lead or open circuit in Heater Supply or Heater. Check wiring. If wiring okay, replace controller. Of WINONA MINNESOTA EAST EIGHTH STREET Page 13 of 13 PHONE
P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.
P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched
More informationPHASE CUT SIGNAL DRIVERS
FEATURES Input to output isolation 27, 40 or 80 watts output power Fused 24VAC power supply Input and power LED indication DESCRIPTION & OPERATION The Digital Controller Interface Module Phase Cut Driver
More informationElectro Controls. Input-Output Modules WattsIndustries.co.uk
Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay
More informationPEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B
PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints
More informationMASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications
L Mobile Communications MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2 Printed in U.S.A Maintenance Manual TABLE OF CONTENTS Page SPECIFICATIONS.....................................................
More information1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA
28231 Ave Crocker Suite 10 Valencia, CA 91355 818-700-8600 Servodynamics.com INFORMATION MANUAL 1525-BRS SERV O D YN A M ICS U SA www.servodynamics.com D y n ad r iv e Bru sh INDEX Page INTRODUCTION 2
More informationSIGNAL INTERFACE MODULE
SIGNAL INTERFACE MODULE FEATURES Optically isolated inputs Field adjustable output Second onboard DC supply Positive / negative voltage output APPLICATIONS Phase cut to ma / VDC conversion Signal scaling
More informationDRG-SC Series Signal Conditioners
DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable
More information815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS
815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS USER GUIDE September 2004 Important Notice This document is subject to the following conditions and restrictions: This document contains proprietary information
More informationAMC mA Positioner
AMC-103 4-20mA Positioner TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM TCAYWOOD@INDELAC.COM SHIPPING ADDRESS: 6810 POWERLINE
More informationAMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers
The Indelac / AC Motor Controllers are used for proportional positioning of split phase AC actuator motors. An external command signal of 0-0V, -V, or -0mA can be used to compare to a feedback signal from
More informationProduct Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control
s 1022/1025/1029C/1032/3629B 3629B Product Data Sheet s 1022/1025/1032 Single phase power controllers Current ratings from 10 to 70 Amps 1022-0 to 5VDC or pot input 1025-4 to 20 ma signal 1032 Current
More informationInstallation, Operation and Maintenance Manual
NIAGARA M513 Rev. B Model 1005 Pulse to DC Converter Installation, Operation and Maintenance Manual Table of Contents General... 1 Specifications... 1 Installation... 1 Theory of Operation... 2 Setup...
More informationANALOG SCALING MODULE
ANALOG SCALING MODULE FEATURES 24V AC operation Output can sink input s pull-up voltage Optional Zero & Span potentiometers Small size 1.10" by 2.19" Two mounting options APPLICATIONS Analog 0 to 5V DC
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationMODEL KBWD-15 Pulse Width Modulated (PWM)
MODEL KBWD-15 Pulse Width Modulated (PWM) DC MOTOR SPEED CONTROL WHISPER DRIVE INSTALLATION AND OPERATING INSTRUCTIONS See Safety Warning on Page 1 and Application Note Warning on Page 2 The information
More informationUNIVERSAL INPUT RESISTANCE OUTPUT
UNIVERSAL INPUT RESISTANCE OUTPUT FEATURES Jumper selectable analog input DIP switch selectable pulse input type DIP switch selectable time bases 256 step output resolution Field changeable resistance
More informationInstallation, Operation and Maintenance Manual
TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation...
More informationISOLATED AC/DC POWER SUPPLY
FEATURES IPS-2/24 Transformer isolation Selectable voltage outputs Thermal overload protected Fused outputs Snap track mounted APPLICATIONS AC power isolation Isolated DC power supply 2, 3 & 4 wire transmitter
More information500mA Laser Diode Controller
IP500 500mA Laser Diode Controller Operating Manual THORLABS, Inc. Ph: (973) 579-7227 435 Route 206N Fax: (973) 300-3600 Newton, NJ 07860 USA www.thorlabs.com Table of Contents TABLE OF FIGURES 1 OVERVIEW
More informationMcPherson Voltage Regulators 4501 NW 27 Ave Miami FL
McPherson Voltage Regulators 4501 NW 27 Ave Miami FL 33142 305-634-1511 To avoid of possible personal injury or equipment damage read and understand this manual before installation. (A.V.R) 208 / 380 /
More informationDynaDrive INFORMATION MANUAL SDFP(S)
DynaDrive INFORMATION MANUAL SDFP(S)1525-17 SERVO DYNAMICS CORP. 28231 Avenue Crocker, Santa Clarita, CA. 91355 (818) 700-8600 Fax (818) 718-6719 www.servodynamics.com INDEX Page INTRODUCTION 2 ELECTRICAL
More informationAD-8100 & AD-8200 Servo Amplifiers
Instruction Manual IM-0607 AD-8100 & AD-8200 Servo Amplifiers Table of Contents General Information... 2 Basic Models... 3 Specifications... 3 Installation Wiring... 3 Setup & Calibration... 4-6 Troubleshooting
More informationStyle FR HI Shunt Track Unit
I UNION SWITCH & SIGNALlimt 645 Russell Street Batesburg, SC 29006 Service Manual 5966 Style FR HI Shunt Track Unit Installation, Operation and Maintenance July, 1980 1980, Union Switch & Signal Inc. Printed
More informationPEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES
PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between
More informationIOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)
IOM Model 1050 Strain Gage Transmitter Installation & Operation Manual (Cage Code #1MU21) Model 1050 Strain Gage Transmitter Installation & Operation Manual CONTENTS I. GENERAL...1 II. INSTALLATION...2
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More information2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE. Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor.
2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor. DISCUSSION The DC Drive of your training system is shown in Figure
More informationTemperature Controller
Temperature Controller E " ective 5/1/78 SPECIFICATIONS : ON-OFF CONTROL FEATURES ON/OFF control Sub-panel mount External bridge board for easy range change Remote setpoint potentiometer Operate with either
More informationPrecision Frequency To Voltage Converter Card
Precision Frequency To Voltage Converter Card Instruction Manual Model C11451-000 Driven by Excellence D.C. DRIVES, A.C. INVERTERS, SOLID STATE STARTERS, SYSTEM INTERFACE CIRCUITS AND ENGINEERED SYSTEMS
More informationBULLETIN # B
Page 1 of 9 BULLETIN # B-18-2002 From: Parts and Service Division Date: February 14, 2002 To: All Authorized Service Agencies SUBJECT: Convection Oven Controller Troubleshooting MODELS AFFECTED: All Garland
More informationUsing the VR448 in place of the Marathon DVR 2000
Using the 448 in place of the Marathon D 2000 D2000E (digital A) provides 7.5A 150VDC Max output short time in compareson to model EA448 (Analog A) thats provide 10 A 160VDC Max output short time Both
More informationDLVP A OPERATOR S MANUAL
DLVP-50-300-3000A OPERATOR S MANUAL DYNALOAD DIVISION 36 NEWBURGH RD. HACKETTSTOWN, NJ 07840 PHONE (908) 850-5088 FAX (908) 908-0679 TABLE OF CONTENTS INTRODUCTION...3 SPECIFICATIONS...5 MODE SELECTOR
More informationInstructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency
www.basler.com + 68.654.234 (USA) info@basler.com Model Description AVC25-0 Voltage Regulator INTRODUCTION The AVC63-2 and AVC25-0 regulate the level of excitation supplied to the field of a conventional,
More informationINSTRUCTIONS PS2500 POWER SUPPLY
INSTRUCTIONS PS2500 POWER SUPPLY The Hoefer PS 2500 Power Supply will furnished power to Constant Voltage or Constant Power modes of operation. It will accurately supply 0-2500 volts, 0-300 ma or 0-375
More informationT6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224
T and T+ are trade names of Trol Systems Inc. TSI reserves the right to make changes to the information contained in this manual without notice. publication /4A115MAN- rev:1 2001 TSI All rights reserved
More informationLab 2: DC Circuits Lab Assignment
2 class days 1. I-V curve for various components Source: Curtis, 1.2.1. (HH 1.1, 1.2, 1.3) Lab 2: DC Circuits Lab Assignment A passive element is a two-contact device that contains no source of power or
More informationAE-504. Solid Start Paralleling Relay General Instructions OPERATIONS. Parallel. Control. Manual DEVICE INPUT OUTPUT
AE-504 Solid Start Paralleling Relay General Instructions OPERATIONS This solid state relay is used to parallel, control or manually position a Schneider Electric proportional electric geartrain actuator
More information269 Troubleshooting Guide 11/4/98 1
269 Troubleshooting Guide 11/4/98 1 Table of Contents Phase currents 3 Communications. 6 RTDs.. 9 Ground Fault Currents... 13 Output Relays. 15 Analog Output 17 Switch Inputs...18 11/4/98 2 Phase Currents
More information8.5A LOW DROPOUT POSITIVE REGULATORS P R O D U C T I O N D ATA S H E E T
L DOC #: 8582 -xx 8.5A LOW DROP POSITIVE REGULATORS T HE I N F I N I T E P O W E R OF I N N O V A TION DESCRIPTION KEY FEATURES The series ICs are low dropout three-terminal positive regulators with 8.5A
More informationDigital Interface Card DEC005000
Engineering & Manufacturing Solutions Digital Interface Card DEC005000 APPLICATION: The DEC005000 conveniently interfaces industry standard signals 4-20mA, 0-5V or 0-10V with a proportional solenoid valve
More informationDM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018
tm Hardware Reference Manual Document Revision B3 May 16, 2018 MICROKINETICS CORPORATION 3380 Town Point Drive Suite 330 Kennesaw, Georgia 30144 Tel: (770) 422-7845 Fax: (770) 422-7854 Table Of Contents
More informationAmetek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F
Ametek, Inc. Rotron Technical Products Division 100 East Erie St., Suite 200 Kent, Ohio 44240 User's 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2"
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationOwner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL
Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL This manual covers installation, setup, operation and troubleshooting. Read carefully before attempting to install, operate or
More informationWATT TRANSDUCER. Instruction Manual
WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com SPECIFICATIONS Power Supply Input
More informationIRPT2062A IRPT2062A. Power Module for 3 hp Motor Drives. 3 hp (2.2 kw) power output
PRELIMINARY PD 6.122 3 hp (2.2 kw) power output Industrial rating at 150% overload for 1 minute 380-480V AC input, 50/60 Hz 3-phase rectifier bridge 3-phase, short circuit rated, ultrafast IGBT inverter
More informationDR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION
-O Hardware Reference Manual Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION 3380 Town Point Drive Suite 330 Kennesaw, GA 30144 Tel: (770) 422-7845 Fax: (770) 422-7854 www.microkinetics.com
More informationIRPT3054A IRPT3054A. Power Module for 5 hp Motor Drives. 5 hp (3.7 kw) power output
PROVISIONAL IRPT3054A Power Module for 5 hp Motor Drives 5 hp (3.7 kw) power output Industrial rating at 150% overload for 1 minute 380-480V AC input, 50/60 Hz 3-phase rectifier bridge 3-phase, short circuit
More informationSureTest Model ST-1THD & ST-1THDC Instructions
#61-156 #61-157 #61-158 SureTest Model ST-1THD & ST-1THDC Instructions Introduction The SureTest family of Circuit/distortion analyzers identify problems common to electrical circuits and harmonic distortion
More information658 Current to Position Converters
658 Current to Position Converters Current to Position Converters for Solid State Switching Output Adjustable Zero, Span and Deadband Two Wire Input from Controller Operates with 90 to 1000 Ω Feedback
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationTransformer circuit calculations
Transformer circuit calculations This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
More informationTel: (949) Fax: (949) IAA100 Product Manual
IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6
More informationOVEN INDUSTRIES, INC. Model 5C7-362
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...
More informationG+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini
Transition Guide Product Transition Guide to Rev: Page Intentionally Left Blank Transition Guide September 2008 Page 2 of 24 Table of Contents 1.1 Overview...4 1.2 Drive Replacement Checklist...4 1.3 Ratings
More information2 Thermistor + Op-Amp + Relay = Sensor + Actuator
Physics 221 - Electronics Temple University, Fall 2005-6 C. J. Martoff, Instructor On/Off Temperature Control; Controlling Wall Current with an Op-Amp 1 Objectives Introduce the method of closed loop control
More informationMICROTC LINEAR THERMOCOUPLE AMPLIFIER OPERATOR S MANUAL
321 E. Huron Street Milford, MI 48381 (248) 685-3939 Fax: (248) 684-5406 8500 Ance Road Charlevoix, MI 49720 (231) 547-5511 Fax: (231) 547-7070 http://www.michsci.com mscinfo@michsci.com MICROTC LINEAR
More informationPART # mA Positioner
PART #22018 4-20mA Positioner TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM TCAYWOOD@INDELAC.COM SHIPPING ADDRESS: 6810 POWERLINE
More informationPID CONTROLLERS LT SERIES
PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4
More informationOperation and Maintenance Manual
WeiKedz 0-30V 2mA-3A Adjustable DC Regulated Power Supply DIY Kit Operation and Maintenance Manual The WeiKedz Adjustable DC Regulated Power Supply provides continuously variable output voltage between
More informationKX120.2 / KX150.2 / KX200.2
KX120.2 / KX150.2 / KX200.2 Congratulations! You have just purchased the latest in amplifier technology to carry the famous KICKER name. Your KICKER KX series amplifier is designed and built to give you
More informationControl Concepts Model 1029C Power Control System Instruction Manual
Control Concepts Model 1029C Power Control System Instruction Manual Another quality product from: 7128 Shady Oak Road Eden Prairie, MN 55344 USA (952) 949-9009 Fax (952) 949-9559 www.researchinc.com CONTROL
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationHeliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC
Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC IMPORTANT DISCLAIMER: Niether Heliotrack,LLC nor Inspeed assume any responsibility for damages caused by the
More informationUNIVERSAL INPUT TO PULSE CONVERTER MODULE
UNIVERSAL INPUT TO PULSE CONVERTER MODULE FEATURES Optional feedback input for closed loop control Jumper selectable analog input DIP switch selectable input/output pulse types Open collector or 24VAC
More informationS1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR
RODIX INC. FEEDER CUBE FC90 Plus Series ADVANCED FEATURES Optional software features of the 24490 / 2449 circuit boards OVERVIEW: The FC90 Plus Series of feeder controls are built around the circuit boards
More informationPEOPLE IN CONTROL OF MOTION
MODEL 796500 RESOLVER TO ENCODER CONVERTER FOR MACHINE TOOL, POSITIONING, AND TRANSFER LINE APPLICATIONS *** APPLICATIONS *** Ideal For Closed Loop Positioning Systems Machine Tools Nuclear Applications
More informationIRPT1053A. POWIRTRAIN Power Module for 1 hp Motor Drives
1 hp (0.75kW) power output Industrial rating at 150% overload for 1 minute 180-240V AC input, 50/60Hz 3-phase rectifier bridge 3-phase ultrafast IGBT inverter HEXFRED ultrafast soft recovery freewheeling
More informationPIECAL 820 FIELD CALIBRATION PROCEDURE
Created by: Paul B-G DATE: 3-9-2012 Sheet 1 of 14 Rev. Date Appd CHANGE Approved A 5/7/12 MJK ITIAL RELEASE B 7/3/12 MT Added pre-calibration instructions, other minor changes C 10/17/14 IT ma Ω IS NOW
More informationModel 332 Temperature Controller
94 Instruments Model 332 Temperature Controller Features Operates down to 500 mk with appropriate NTC RTD sensors Model 332 Temperature Controller Two sensor inputs Supports diode, RTD, and thermocouple
More informationPROGRAMED ANALOG CONTROL MODULE
PROGRAMED ANALOG CONTROL MODULE FEATURES Two channel conversion Transformer isolation onboard Isolated 24V AC for Velocity sensor APPLICATIONS Velocity sensor conversions Velocity sensor linearization
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationP.O. BOX 3090 ALBANY, GEORGIA PHONE 229/ FAX 229/ NIGHT LIGHTING SYSTEM AND VOLTAGE REGULATOR CIRCUIT INTERACTION
Rockwell service letter No. SL-AG-66 International P.O. BOX 3090 ALBANY, GEORGIA 31706-3090 PHONE 229/883-1440 FAX 229/439-9790 Service Letter No. SL-AG-66 NIGHT LIGHTING SYSTEM AND VOLTAGE REGULATOR CIRCUIT
More informationExercise 2: Temperature Measurement
Exercise 2: Temperature Measurement EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain the use of a thermocouple in temperature measurement applications. DISCUSSION the
More informationAC Current Monitor model ACM-2
1.0 Safety Warnings The ACM-2 AC Current Monitor should be installed only by qualified technical personnel with knowledge of industrial electrical wiring and the requirements of the national and local
More informationSeries R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting
FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationApril 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions
April TM UCM-A Setpoint Controller Operating and Installation Instructions A LARGE number of applications in a SMALL package... REMOTE SETPOINT CONTROLLER LOCAL SETPOINT CONTROLLER - ma SIGNAL GENERATOR
More informationInstrumentation Amplifier Module. Instruction Manual
Instrumentation Amplifier Module Instruction Manual 1 Thank you for purchasing the INA125 Instrumentation Amplifier Module. The module also contains an active low pass filter and an offset and gain stage.
More informationEX Multi-Point Process Switch KING-GAGE ma Process Control. Single-Channel Analog. Start-Up/Operation Instructions.
Multi-Point ffective: eptember Process witch 2006 (Replaces October 2002) KING-GAG 4-20 Process ontrol X-1711 Multi-Point Process witch ingle-hannel Analog tart-up/operation Instructions Page 1 Multi-Point
More informationDCIM SIGNAL CONVERTERS
DCIM SIGNAL CONVERTERS FEATURES Optically isolated inputs Fused 24V AC power supply Field adjustable output Input & power LED indication Optional minimum position pot APPLICATIONS Phase cut to ma/v DC
More informationINSTRUCTIONS TYPE SBF STATIC BREAKER FAILURE RELAY
Westinghouse I. L. 41-776. 3 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TYPE SBF STATIC BREAKER FAILURE RELAY CAUTION: Before putting relay into service, operate the relay to check the electrical
More informationApitech Valve Drive Board
M511 Apitech Valve Drive Board Completely Independent Adjustments Current Sourcing PWM Outputs 2 Current Ranges, MID and HI 1-1500 ma PWM Current Range Independent HIA and HIB adjustments Adjustable MID
More informationSealed Interface Control: EC20300
ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent
More informationKX550.3 / KX KX Amplifier Features
KX550.3 / KX700.5 Congratulations! You have just purchased the latest in amplifier technology to carry the famous KICKER name. Your KICKER KX series amplifier is designed and built to give you years of
More informationSERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company
SERIES 70 R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL The High Performance Company Contents 1.0 Safety Instructions - Definition of Terms 2 1.1 Hazard-free Use 2 1.2 Qualified Personnel 2
More informationModel 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R
O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com
More informationSmartFan Multi SD. Speed Control for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.
SmartFan Multi SD Speed Control for DC Fans The driving force of motor control & electronics cooling. DC Controls SmartFan Multi SD is a fan speed control and temperature alarm designed for DC fans and
More informationEvolution. EC Motor Series 1. Automation Interface CONTROLS INC. EVO /ECM-ACU+ Application. Ordering
Evolution Automation Interface COTROLS IC. EVO /ECM-ACU+ EC Motor Series 1 Application The allows industry standard 0V to +10V automation signals to adjust and monitor EC Motors. These are fractional horsepower
More information40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR
40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationElectronic Fundamentals (Digital and Analogue) (2hours)
C1.0 ANALOGUE FUNDAMENTALS COMPETITOR S INSTRUCTION:- Attempt all questions: Circle the letter that indicates the correct answer. C1.1 The prefix nano stands for: (a) 106 (b) 103 (c) 10 3 (d) 10 6 (Marks
More informationMAXTHERMO-GITTA GROUP CORPORATION. Hot Runner Temperature Controller. MC-550 Operation Manual. Version:
Hot Runner Temperature Controller MC-550 Operation Manual Version:1011040001 http://www.maxthermo.com To avoid injury or damage caused by improper operation, please follow The instruction and keep the
More informationLab #2 Voltage and Current Division
In this experiment, we will be investigating the concepts of voltage and current division. Voltage and current division is an application of Kirchoff s Laws. Kirchoff s Voltage Law Kirchoff s Voltage Law
More informatione Pb PID-1500 PID-1500 TEMPERATURE CONTROLLER Thermoelectric & Resistive Heater Plug-n-Play Temperature Controller GENERAL DESCRIPTION:
PID-500 Thermoelectric & Resistive Heater Plug-n-Play Temperature Controller GENERAL DESCRIPTION: The PID-500 Linear Bipolar, Thermoelectric Temperature Controller provides ultra-stable, low noise temperature
More informationInstallation Tech Note Dallas, Texas
AMC B40A40AC Installation Tech Note Dallas, Texas May, 2010 ! CAUTION! Do NOT apply air pressure to release the collet while the servo motor is rotating. The servo motor spindle must be FULLY STOPPED before
More informationYaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)
Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Section Two: Power Checks Page 2 Check box when completed Power Checks TEST
More informationCopyright 2014, R. Eckweiler & OCARC, Inc. Page 1 of 6
HOM rev. new Heathkit of the Month: by Bob Eckweiler, AF6C Heathkit of the Month #59 - IG-72 Audio Generator TEST EQUIPMENT Heathkit IG-72 Audio Generator. Introduction: The IG-72 Audio Oscillator is a
More information