1 GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented Freq range: 4 Hz to 70 khz Dyn range: 44 db(a) to 174 db Sensitivity: 1.6 mv/pa The 40BD-FV is an IEC WS3P ¼" prepolarized pressure microphone with front venting. It is a highprecision condenser microphone made according to IEC requirements. Its low sensitivity makes it ideal for sound measurements at high sound pressure levels of up to 166 db. Its small size reduces the effects of diffraction and reflections around the microphone, resulting in a frequency range that extends up to 70 khz. GRAS Sound & Vibration A/S Skovlytoften 33, 2840 Holte, Denmark
2 Technology Page: 2 Introduction Quality and warranty The 40BD-FV is an IEC WS3P ¼" prepolarized pressure microphone with front venting. Read about the externally polarized equivalent [ GRAS 40BP-FV] It is a high-precision condenser microphone made according to IEC requirements. Its low sensitivity makes it ideal for sound measurements at high frequencies and high sound pressure levels of up to 174 db. Its small size reduces the effects of diffraction and reflections around the microphone, resulting in a frequency range that extends up to 70 khz. 40BD-FV is individually factory-calibrated and delivered with a calibration chart stating its specific open-circuit sensitivity and pressure frequency response. Typical applications and use The 40BD-FV is ideal for sound pressure measurements, as well as high frequency and high level pressure measurements. It is suitable for general purpose acoustic measurements in couplers and at boundaries. 40BD-FV is included in the GRAS 46BD-FV ¼" Pressure microphone set. Compatibility The 40BD-FV requires a standardized ½" or ¼" CCP preamplifier and an input module that supports this technology with a BNC, SMB, or Microdot connector. System verification For daily verification and check of your measurement setup, we recommend using a calibrator like GRAS Sound Level Calibrator 42AG. For proper sensitivity calibration, we recommend using a pistonphone like GRAS Intelligent Pistonphone 42AP. All GRAS microphones are made of high-quality materials that will ensure life-long stability and robustness. The microphones are all assembled in verified clean-room environments by skilled and dedicated operators with many years of expertise in this field. The microphone diaphragm, body, and improved protection grid are made of high-grade stainless steel, which makes the microphone resistant to physical damage, as well as corrosion caused by aggressive air or gasses. This, combined with the reinforced gold-plated microphone terminal which guarantees a highly reliable connection, enables GRAS to offer 5 years warranty against defective materials and workmanship. Service If you accidentally damage the diaphragm on a GRAS microphone, we can in most cases replace it at a very reasonable cost and with a short turnaround time. This not only protects your investment, but also pleases your quality assurance department because you don't have to worry about new serial numbers, etc. Calibration Before leaving the factory, all GRAS microphones are calibrated in a controlled laboratory environment using traceable calibration equipment. Depending on the use, measurement environment, and internal quality control programs, we recommend recalibrating the microphone at least once a year.
3 Specifications Page: 3 Frequency range (±1 db) Hz 10 to 25 k Frequency range (±2 db) Hz 4 to 70 k Dynamic range lower limit (microphone thermal noise) db(a) 34 Dynamic range lower limit with GRAS preamplifier db(a) 44 Dynamic range upper limit with GRAS +28 V / ±14 V power supply Dynamic range upper limit with GRAS +120 V / ±60 V power supply db 166 db 174 Dynamic range upper limit with GRAS CCP preamplifier db 166 Open-circuit 250 Hz (±3 db) mv/pa 1.6 Open-circuit 250 Hz (±3 db) db re 1V/Pa -56 Resonance frequency khz 50 Microphone cartridge capacitance, typ. pf 7 Microphone venting Front IEC Compliance N/A Temperature range, operation C / F -40 to 120 / -40 to 248 Temperature range, storage C / F -40 to 85 / -40 to 185 Temperature Hz db/ C / db/ F / Static pressure Hz db/kpa Humidity range non condensing % RH 0 to 100 Humidity Hz db/% RH Influence of axial m/s² db re 20 µpa 55 CE/RoHS compliant/weee registered Yes / Yes, Yes Weight g / oz 1.5 / 0.053
4 Specifications Page: 4 Typical frequency response (without protection grid) GRAS Sound & Vibration reserves the right to change specifications and accessories without notice.
5 Dimensions Page: 5
6 We Make Microphones Tradition Since the establishment in 1994, GRAS has been 100% dedicated to developing and manufacturing high-quality measurement microphones and related acoustic equipment. Innovation We work with everybody with an interest in sound or noise within the fields of aerospace, automotive, audiology, consumer electronics, noise monitoring, building acoustics and telecommunications. Quality At GRAS we know that in order for you to trust your measurement results; signal quality, stability and robustness are essentials. We design and build them to perform under real life conditions and beyond. GRAS Sound & Vibration A/S Skovlytoften 33, 2840 Holte, Denmark
PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683
PRODUCT DATA Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity.
More informationG.R.A.S. Sound & Vibration
Instruction Manual Sound-intensity Calibrator Type 51AB G.R.A.S. Sound & Vibration Skovlytoften 33, 2840 Holte, Denmark Tel. +45 45 66 40 46 Fax +45 45 66 40 47 Sound-intensity Calibrator Type 51AB Revision
More informationMicrophone Cartridge Model: MP201
BSWA MICROPHONES Established in 1998, BSWA Technology Co., Ltd is becoming a preferred microphone supplier in China and the world. With the high quality and low price strategy, many OEMs and system integrators
More informationMicrophones & Accessories
Accessories of the KLIPPEL R&D and QC SYSTEMs (Document Revision1.15) FEATURES Microphones optimal for research, development and manufacturing of transducers Condenser and electret microphones High performance/cost
More informationPRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683
PRODUCT DATA Probe Kit Type 3599 Microphone Pair Type 4197 Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity. Specially designed for use with Brüel & Kjær
More informationPRODUCT DATA. Applications. Uses
PRODUCT DATA Impedance Tube Kit (50 Hz 6.4 khz) Type 4206 Impedance Tube Kit (100 Hz 3.2 khz) Type 4206-A Transmission Loss Tube Kit (50 Hz 6.4 khz) Type 4206-T Brüel & Kjær offers a complete range of
More informationPRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683
PRODUCT DATA Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683 Type 3595 is a two-microphone probe kit for measuring sound intensity. Specially
More informationMulti-field Microphone when the Sound Field is unknown
Multi-field Microphone when the Sound Field is unknown Svend Gade, Niels V. Bøgholm Brüel & Kjær Sound & Vibration A/S, Skodsborgvej 307 2850 Nærum, Denmark ABSTRACT Only a small percentage of all acoustical
More informationTechnical Data Measurement Microphones
Technical Data s Consisting of Type Classification according IEC 61672 and ANSI S1.4 Capsule / Transducer Maximum SPL @ THD 3%, 1 khz 22 Certified MA220 + MC230 or MC230A Capsule Certified -WP Outdoor
More informationApplication Note. Airbag Noise Measurements
Airbag Noise Measurements Headquarters Skovlytoften 33 2840 Holte Denmark Tel: +45 45 66 40 46 E-mail: gras@gras.dk Web: gras.dk Airbag Noise Measurements* Per Rasmussen When an airbag inflates rapidly
More informationNor150 Sound Intensity Option Sound intensity probe Nor1290
Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative
More informationHigh Resolution Ear Simulator
High Resolution Ear Simulator By Morten Wille October 17 index Introduction... 3 The standard Ear Simulator...3 Measurements with the standard Ear Simulator...4 Measuring THD and other distortion products...6...
More informationC1.1 Specification of the SVAN 971 as SLM in the standard configuration
SVAN 971 USER MANUAL. C TECHNICAL SPECIFICATIONS C.1 Specification of SVAN 971 as sound level meter The following appendix effects for firmware version 1.11.1 or greater. C1.1 Specification of the SVAN
More informationPRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.
PRODUCT DATA Impedance Tube Kit (50 Hz 6.4 khz) Type 4206 Impedance Tube Kit (100 Hz 3.2 khz) Type 4206 A Transmission Loss Tube Kit (50 Hz 6.4 khz) Type 4206 T Brüel & Kjær offers a complete range of
More informationReciprocity calibration of Laboratory. Standard Microphones. There is simply no substitute for knowing what you re doing
Reciprocity calibration of Laboratory Standard Microphones Maria Enge, Philipp Begoff, Frank Schulz There is simply no substitute for knowing what you re doing Jeff Case www.spektra-dresden.com Topics
More informationSW Series Impedance Tube Solutions
SW Series Impedance Tube Solutions BSWA SW series Impedance Tubes can accurately measure sound absorption coefficients and impedance according to ISO or ASTM standards. They also support the sound transmission
More informationPRODUCT DATA. Sound Intensity Calibrator Type Uses and Features
PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on site sound pressure calibration and pressure residual intensity index verification. Its most important
More informationNor150 Sound Intensity Option Sound intensity probe Nor1290
Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative
More informationinstructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION
instructions for Models QC-10 and QC-20 Sound Calibrators GENERAL DESCRIPTION MODELS QC-10/QC-20 SOUND CALIBRATORS The Quest model QC-10 and QC-20 are acoustic calibrators for calibrating precision type
More informationTechnical Documentation
Technical Documentation Microphone Type 4964 for Hand-held Analyzer Types 2250, 2250-L and 2270 Supplement to Instruction Manual BE 1712 English BE 1864 11 Microphone Type 4964 for Hand-held Analyzer
More informationBSWA Technology. Product Catalogue
BSWA Technology Product Catalogue COMPANY OVERVIEW BSWA Established in 1998, BSWA Technology Co., Ltd. is an acoustical company covering the businesses: - Manufacturing the world class measurement microphones
More informationPRODUCT DATA. Sound Intensity Calibrator Type 4297
PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on-site sound-pressure calibration and pressure-residual intensity-index verification. Its most important
More informationOPERATING MANUAL. Measurement Microphones
OPERATING MANUAL Measurement Microphones Contact NTi Audio at Headquarters +423 239 6060 info@nti-audio.com Americas +1 503 684 7050 americas@nti-audio.com China +86 512 6802 0075 china@nti-audio.com Czech
More informationTesting to IEC
APPENDIX B Testing to IEC61672-1 This appendix presents information for measuring the sound level meter functionality of the LxT according to IEC61672-1. Sections 5, 6, 7 and 9 (except 9.3) The following
More informationMeasurement Microphone MI Series
Measurement Microphone MI Series Types to suit your needs include high sensitivity and wide frequency models. High degree of environmental stability against temperature and humidity. Condenser-type microphone
More informationPRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670
PRODUCT DATA Falcon Range 1/4-inch Microphone Preamplifier Type 2670 1/4-inch Microphone Preamplifier Type 2670 is a Falcon Range product for precision acoustic measurements with Brüel & Kjær s wide rangf
More informationM I C R O P H O N E S E x p r e s s i o n i s e v e r y t h i n g
4099 MICROPHONES E x p r e s s i o n i s e v e r y t h i n g Superior gain-before-feedback Wireless compatible One-hand mounting Holder gentle to the instrument Expression is everything 4099 Microphones
More informationINSTALLATION GET CLOSER TO TROUBLE-FREE SOUND
INSTALLATION GET CLOSER TO TROUBLE-FREE SOUND Enabling outstanding sound in acoustically-challenging venues can be very tricky. But choosing the proper microphones makes everything easier. The right mics
More informationSelection and Calibration of Acoustic Sensors
Selection and Calibration of Acoustic Sensors Tamil Chandran. A Senior Research Engineer Fluid Control Research Institute Palakkad, India Surendran. P Chief Research Engineer Fluid Control Research Institute
More informationData Sheet. Description The 6918 is a unit consisting of a directional and an omni-directional microphone for hearing instruments.
Description The 6918 is a unit consisting of a directional and an omni-directional microphone for hearing instruments. Features - Low noise CMOS amplifier with improved power supply feedtrough attenuation
More informationTECHNICAL NOTES. Sound Level Meter NA Higashimotomachi, Kokubunji, Tokyo , Japan
TECHNICAL NOTES Sound Level Meter NA-28 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan http://www.rion.co.jp/english/ Organization of the NA-28 Documentation The documentation for the Sound
More informationAcoustic Measurement Sensors & Instrumentation
P C B P I E Z O T R O N I C S, I N C. Acoustic Measurement Sensors & Instrumentation PCB.com/Acoustics MTS SYSTEMS CORPORATION 716.684.0001 PCB Trusted by Companies and Laboratories Worldwide PCB Piezotronics,
More informationSpeechLine Wired MEB 102 (-L), MEB 104 (-L) Install Boundary Layer Microphone
1/5 FEATURES Unobtrusive, timeless design Optimized for speech Made in Germany Compact and unobtrusively designed, the boundary layer microphones MEB 102 (omnidirectional) and MEB 104 (cardioid) fits any
More informationAn automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements
An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements E. Aflalo a, F. Dupont a, P. Cellard b and J.-N. Durocher b a 01dB-Metravib,
More informationSLM-52N INSTRUCTION MANUAL
ISO-TECH Sound Level Meter SLM-52N INSTRUCTION MANUAL Un Un Ov Ov CONTENTS Title Page 1. INSTRUMENT CARE... 1 2. FEATURES... 2 3. MEASUREMENT PARAMETERS... 2 4. SPECIFICATIONS... 2 5. CONTROLS AND FUNCTIONS...
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Sound level meters Sonomètres OIML R 58 Edition 1998 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Construction and maximum permissible
More informationHigh Sensitivity Triaxial CCLD Accelerometer Type 4506-B-003
P R O D U C T DATA High Sensitivity Triaxial CCLD Accelerometer Type 4506-B-003 Type 4506-B-003 is a high sensitivity triaxial piezoelectric CCLD* accelerometer. The accelerometer is housed in robust titanium
More informationNEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain
SENSORS FOR RESEARCH & DEVELOPMENT AND MACHINERY HEALTH MONITORING NEW FROM PCB Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain www.pcb.com info@pcb.com 800.828.8840
More informationPRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B
PRODUCT DATA Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B Types 4524 and 4524 B are lightweight triaxial piezoelectric OrthoShear accelerometers, each with
More informationModel Microphone Preamplifier Power Supply Manual
Model 2221 Microphone Preamplifier Power Supply Manual Larson Davis Model 2221 Microphone Preamplifier Power Supply Manual I2221.01 Rev H Copyright Copyright 2009-2015 by PCB Piezotronics, Inc. This manual
More informationOPERATING MANUAL. Measurement Microphones
OPERATING MANUAL Measurement Microphones Contact NTi Audio at Headquarters +423 239 6060 info@nti-audio.com Americas +1 503 684 7050 americas@nti-audio.com China +86 512 6802 0075 china@nti-audio.com Czech
More informationCalibration Certificate
ÌÇa8SÈ-EÇÂ!ÈfeFÎ Calibration Certificate Date of issue 2015-12-08 Calibrated by Gert Schnipper Approved by Ole F. Carlsen 1 (5) CUSTOMER: GN RESOUND A/S GTO LAUTRUPBJERG 7-9 2750 BALLERUP DEVICE UNDER
More informationSound Meter Type
Sound Meter Type 1 840015 Sound Meter Type 1-840015 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form
More informationUser s manual. d:facto. d:facto II Vocal Microphone d:facto II Handle d:facto II Adapters for Wireless Systems.
User s manual d:facto d:facto II Vocal Microphone d:facto II Handle d:facto II Adapters for Wireless Systems www.dpamicrophones.com/dfacto Application and use The DPA d:facto II vocal mic is a high quality
More informationPRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses
PRODUCT DATA 16-channel DeltaTron Conditioning Amplifiers s -A/B/C/D The family of 16-channel DeltaTron conditioning amplifiers comprises of general signal- conditioning amplifiers for voltage and DeltaTron
More informationAC/DC Current Oscilloscope Probe Model SL261
AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationPRODUCT DATA. Hydrophones Types 8103, 8104, 8105 and 8106
PRODUCT DATA Hydrophones Types 8103, 8104, 8105 and 8106 hydrophones are individually calibrated waterborne-sound transducers which have a flat frequency response and are omnidirectional over a wide frequency
More informationCertificate of Calibration Sound Level Meter
NTacoustic coustic Calibration & Testing Laboratory Level 1, 418 Elizabeth Street., Surry Hills NSW 2010 USTRLI Ph: (02) 8218 0570 email: service@natacoustic.com.au website: www.natacoustic.com.au division
More informationBROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz
INSTRUCTION MANUAL BROADBAND PREAMPLIFIER MODEL BPA-1000 10 khz 1 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN. 1994
More informationNEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain
SENSORS FOR RESEARCH & DEVELOPMENT AND MACHINERY HEALTH MONITORING NEW FROM PCB Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain www.pcb.com Info@PCB.com 800.828.8840
More informationSC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles
Class 1 integrating sound level meter with measurement protocols Applications Includes measurement protocols for: MEASURING NOISE HAS NEVER BEEN SO EASY Noise generated by motor vehicles D_SC101_v0015_20120703_ENG
More informationNon-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes
4810 Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes Sub nanometer resolution for ultra-precise measurements Exceptional temperature stability Wide variety of precision capacitive
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Integrating-averaging sound level meters Sonomètres intégrateurs-moyenneurs OIML R 88 Edition 1998 (E) CONTENTS Foreword...
More informationSPEAKER SC-COBRA-WP
SPEAKER-1115-3.5-SC-COBRA-WP The 11 15 3.5 mm COBRA-WP is an advanced miniature speaker of rectangular shape, specifically is a high end miniature speaker specifically designed for waterproof applications
More informationBedienungsanleitung Instructions for use Notice d emploi Istruzoni per l uso Instrucciones de uso Gebruiksaanwijzing 912 S
Bedienungsanleitung Instructions for use Notice d emploi Istruzoni per l uso Instrucciones de uso Gebruiksaanwijzing 912 S 912 S The boundary microphone 912 S is a high-quality, prepolarized condenser
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) TABLE OF CONTENTS GENERAL DESCRIPTION... 1 SPECIFICATIONS... 2 OPERATION... 5 Controls... 5 Principles of Operation...
More informationSPEAKER SC-COBRA-PEEK-WP
2403 260 00132 SPEAKER-1115-3.5-SC-COBRA-PEEK-WP The 11 15 3.5 mm COBRA-PEEK-WP is an advanced miniature speaker of rectangular shape, specifically is a high end miniature speaker specifically designed
More informationOperation manual. Model 24 Infrasound Sensor
Operation manual for the Model 24 Infrasound Sensor For use in the near infrasound band 903 Koyukuk Dr. P.O. Box 757320 Fairbanks, AK 99775-7320 Tel: 907-474-7107 Fax: 907-474-7290 chaparral@gi.alaska.edu
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationREPORT ON KEY COMPARISON APMP.AUV.A K3
REPORT ON KEY COMPARISON APMP.AUV.A K3 1 December, 2008 Dr Hyu-sang Kwon Korea Research Institute of Standards and Science (KRISS) 1 Abstract A regional key-comparison APMP.AUV.A K3 has been carried out
More informationThe cutting edge of evolution
series 900 e The cutting edge of evolution Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 Wedemark, Germany Phone: +49 (51 30) 60 00, Fax: +49 (51 30)60 03 00 www.sennheiser.com e 900 Introducing
More informationPRODUCT DATA. The NEXUS Range of Conditioning Amplifiers Types 2690, 2691, 2692 and Uses And Features
PRODUCT DATA The NEXUS Range of Conditioning Amplifiers Types 2690, 2691, 2692 and 2693 The NEXUS concept is based on flexibility. A single mainframe, a variety of input and output channels, and different
More informationevolution wireless G4 ew 112 P G4 Camera Lavalier ME 2 Set ew 122 P G4 Camera Lavalier ME 4 Set
1/7 A broadcast quality sound solution. Providing the highest flexibility for your video sound and field recording applications. A robust wireless microphone system that offers excellent sound quality,
More informationDC to 400 MHz (40 db Typ. Isolation up to 20 GHz)
Coaxial Low Pass Filter 5Ω DC to 4 MHz (4 db Typ. Isolation up to 2 GHz) The Big Deal Very good rejection, 4 db typ. up to 2 GHz Excellent power handling, 1W Rugged unibody construction CASE STYLE: FF1118
More informationPRODUCT DATA. Piezoelectric Charge Accelerometer Types 4326-A and 4326-A-001. Uses and Features
PRODUCT DATA Piezoelectric Charge Accelerometer Types 6-A and 6-A- Types 6-A and 6-A- are triaxial piezoelectric accelerometers with three independent outputs for simultaneous high-level measurements in
More informationMicrophone calibration service for airborne ultrasound
Microphone calibration service for airborne ultrasound Christoph KLING Physikalisch-Technische Bundesanstalt (PTB), Germany ABSTRACT The application of ultrasound techniques is wide-spread in many fields
More informationDONAU SLIM ENHANCED 11x15x3.0 mm SPEAKER
DONAU SLIM ENHANCED 11x15x3.0 mm SPEAKER The 11 x 15 x 3.0 mm rectangular speaker is a high end miniature speaker specifically designed for portable devices and smartphones where high quality sound is
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) A.H. Systems Model Active Monopole Antennas Active Monopole Antenna Series Operation Manual 1 TABLE OF CONTENTS INTRODUCTION
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationcardioid condenser performance microphone
cardioid condenser performance microphone congratulations From Blue Microphones, makers of the finest studio recording microphones you can find, comes the en CORE 300 a flagship condenser performance microphone
More informationMini Circuits SMA Attenuators
Mini Circuits 15542 SMA Attenuators For rugged, reliable, and repeatable attenuation when accuracy is key, our customers have come to rely on Mini Circuits Fixed. Precision Attenuators. They feature stainless
More informationevolution wireless G4 ew 300 G4-HEADMIC1-RC Bodypack Headmic Set
1/8 Best choice for your business, top of the class in education. The G4 300 Series uses the power of an increased switching bandwidth of up to 88 MHz. New frequency ranges allow to operate multi-channel
More informationrugged and versatile active dynamic microphone
rugged and versatile active dynamic microphone congratulations From Blue Microphones, makers of the finest studio recording microphones you can find, comes the en CORE 200, a studio-grade handheld dynamic
More informationData Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved
Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...
More informationProduct and Measurement Solutions for the Automotive Industry
Product and Measurement Solutions for the Automotive Industry Car body and vehicle related measurement solutions P.4-5 Acceleration noise measurement Acceleration Noise Measurement System Measurement of
More informationVM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output
VM2000 2017 Data Sheet Vesper Technologies Inc. Low-Noise Bottom Port Piezoelectric MEMS Microphone VM2000 Vesper offers the world s first differential analog piezoelectric MEMS microphone. VM2000 provides
More informationTypical Performance Curves
Coaxial SMA Fixed Attenuator 50Ω 1W 3dB DC to 6000 MHz Maximum Ratings Operating Temperature -45 C to 100 C Storage Temperature -55 C to 100 C Permanent damage may occur if any of these limits are exceeded.
More informationManufacturer Calibration Certificate
Manufacturer Calibration Certificate The sound meter submitted for testing successfully completed the periodic tests of IEC 61672-3. All tests are traceable in accordance with ISO/IEC 17025. This model
More informationAgilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers
Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers Technical Specifications May 2003 The Agilent 81662A low power and 81663A high power DFB Laser Source modules are best suited
More informationApproved Signatory: A.Vreeswijk 21-Mar Mar-2017
CUSTOMER Name: Address: Zip code & City : Country: AV Consulting Laboratory Benedenberg 100A 2861 LH Nederland CALIBRATION OF Device: Hand-held Analyzer Brand & type: Bruel & Kjaer NEXUS 2693 Serial number:
More informationSEIT 1928 MICROTECH GEFELL
SEIT 1928 KONDENSATORMIKROFONE FÜR STUDIO - UND MESSTECHNIK MICROTECH GEFELL UM 9 TUBE CONDENSER MICROPHONE with phantom powering 48 V Large diameter dual diaphragm capsule, switchable Balanced output
More informationUser s Manual DPA 4099 Sax Sax Clip Microphone. DPA 4099 Trumpet Trumpet Clip Microphone. DPA 4099 Guitar Guitar Clip Microphone
4099_9x15_manual.indd 1 User s Manual DPA 4099 DPA 4099 Sax Sax Clip Microphone DPA 4099 Trumpet Trumpet Clip Microphone DPA 4099 Guitar Guitar Clip Microphone DPA 4099 Violin Violin Clip Microphone Expression
More informationUsing the Equalization Adjustments. Description
RE38N/D Dynamic Cardioid Microphone Exclusive 16 position equalization switch Flexible mechanical design for optimum positioning Large diaphragm for extended frequency response High N/DYM sensitivity Description
More informationBENNING. CM7 Electrical Tester. Service Information
BENNING CM7 Electrical Tester Service Information TABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specification
More informationevolution wireless G4 ew 500 FILM G4 Pro Camera Lavalier MKE 2 +
1/9 The professional s choice for broadcast quality sound Providing the highest flexibility for your video sound and field recording applications. A robust wireless microphone system that offers ultimate
More informationinstructions for Model 1800 Precision Integrating Sound Level Meter and Model OB-100 Octave Band Filter and Model OB-300 1/1-1/3 Octave Band Filter
instructions for Model 1800 Precision Integrating Sound Level Meter and Model OB-100 Octave Band Filter and Model OB-300 1/1-1/3 Octave Band Filter TABLE OF CONTENTS MODEL 1800 PRECISION IMPULSE INTEGRATING
More informationevolution wireless G4 ew 100 G4-ME2 ew 100 G4-ME4 Lavalier Set
1/7 Versatile wireless systems for those who sing, speak or play instruments with up to 42 MHz tuning bandwidth in a stable UHF range and fast, simultaneous setup of up to 12 linked systems. The perfect
More informationstudio-grade dynamic performance microphone
studio-grade dynamic performance microphone congratulations From Blue Microphones, makers of the finest studio recording microphones you can find, comes the en CORE 100, a studio-grade handheld dynamic
More informationevolution wireless G4 ew 500-G4-MKE 2 Lavalier Set
1/7 The pro s choice. Renowned sound engineers rely on ew 500 G4 s flexibility, especially when handling multi-channel settings on the world s music stages. Up to 88 MHz bandwidth, up to 32 channels. Ethernet
More informationPRODUCT DATA 4397A/ 8A/ 9A. Description. Miniature DeltaTron Accelerometer Type 4397A DeltaTron Accelerometers Types 4398A, 4399A FEATURES USES
PRODUCT DATA Miniature DeltaTron Accelerometer Type 4397A DeltaTron Accelerometers Types 4398A, 4399A DeltaTron is the generic name for the family of accelerometers and signal conditioning products from
More informationBSWA Impedance Tube Solutions
BSWA Impedance Tube Solutions Version: 20008 BSWA Company Introduction Established in 998, BSWA Technology Co., Ltd. is becoming the preferred supplier for acoustical measurements. With headquarter located
More information80i-110s AC/DC CURRENT PROBE
Table of Contents 3 80i-110s AC/DC CURRENT PROBE Users Manual November 1996 1994, 1996 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Printed in
More informationMODEL W Power Amplifier
TEGAM, INC. MODEL 2348 18.75 W Power Amplifier This owner s manual was as current as possible when this product was manufactured. However, products are constantly being updated and improved. Because of
More informationInstruction (EMC, LVD)
Instruction S1 Manual (EMC, LVD) S1 The S1 is the result of over 30 years experience in stage sound technology. The design brief was simple, build the best vocal mic in the world! How do you achieve that?
More informationTemposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.
R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH 25 7600 mm Perfect data processing 0.5 μm Rugged industrial sensor Linear and absolute measurement LEDs for sensor
More informationTM1. # Designed and engineered in the U.K. Why a Condenser Mic?
Package of microphone, shock mount with integrated pop shield, 20' (6 m) XLR cable and dust cover Premium large condenser microphone capsule with 1" gold plated diaphragm Internal shock mounting for microphone
More informationAN5E Application Note
Metra utilizes for factory calibration a modern PC based calibration system. The calibration procedure is based on a transfer standard which is regularly sent to Physikalisch-Technische Bundesanstalt (PTB)
More informationDante Kit MEB 114-S. Thanks to its rugged housing and its high-quality microphone capsule the MEB 114-S ensures the best speech intelligibility.
PRODUCT SPECIFICATION 1/6 FEATURES Great speech intelligibility Phantom power via PoE Remote controllable gain level Daisy-chaining possible DELIVERY INCLUDES 1 SL DI 4 XLR Dante interface 4 MEB 114-S
More informationPRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial Charge Accelerometers Types 4326-A and 4326-A-001
PRODUCT DATA Piezoelectric Accelerometer Miniature Triaxial Charge Accelerometers Types 436-A and 436-A-1 Types 436-A and 436-A-1 are triaxial piezoelectric ThetaShear patented accelerometers with three
More informationLOW NOISE AMPLIFIER SA SERIES
LOW NOISE AMPLIFIER SA SERIES Accurate and ultra low noise measurements of very small signals Achieve one of the highest level of low noise amplification SA600 series SA400 series Differential input SA200
More information