Smart Field Communicator SET URV ITEM. Can be ordered separately see specification 34-ST-03-55

Size: px
Start display at page:

Download "Smart Field Communicator SET URV ITEM. Can be ordered separately see specification 34-ST-03-55"

Transcription

1 ST 3000 Smart Transmitter Series 900 Flange Mounted Liquid Level Models STF924 0 to 400 inh 2 O 0 to 1000 mbar STF932 0 to 100 psi 0 to 7 bar STF92F 0 to 400 inh 2 O 0 to 1000 mbar STF93F 0 to 100 psi 0 to 7 bar 34-ST /98 Specification and Model Selection Guide Function Honeywell s ST 3000 Series 900 Flange Mounted Liquid Level Transmitters bring proven smart technology to a wide spectrum of liquid level measurement applications with varying process interface requirements. They measure head pressure caused by changes in liquid level and transmit an output signal proportional to the measured variable in either an analog 4 to 20 milliampere format or in a digital DE protocol format for direct digital integration with our TDC 3000 X control system. An optional electronics module is available for the Series 900 that provides HART ¹ Protocol compatibility. A future protocol option will let you use these transmitters in FOUNDATION Fieldbus² networks. Smart Field Communicator ST 3000 Flange Mounted Liquid Level Transmitter Models: STF924 STF932 In the standard transmitter you easily select the analog or digital transmission format through the Smart Field Communicator (SFC ) which is the common hand-held operator interface for our DE-based Smartline Transmitters. All configuration, operation, and communications functions are under the control of the ST 3000 Smart Transmitter s microprocessor and are accessible through the SFC. TAG No. SFC WORKING... Can be ordered separately see specification 34-ST ID CONF LRV 0% MENU ITEM DAMP UNITS URV 100% SET OUT- PUT NEXT STAT PREV SPAN NUM/ ALPHA SHIFT COR- RECT +/- CLR ENTER (NO) (YES) ST 3000 Differential Pressure Transmitter with Flange on One Side Models: STF92F STF93F ¹ HART is a registered trademark of the Hart Communication Foundation. ² FOUNDATION Fieldbus is a trademark of the Fieldbus Foundation. Figure 1 Series 900 Flange Mounted Liquid Level Transmitters feature proven smart technology and come in flush diaphragm, and extended diaphragm models as well as pseudo flange types. See Specification 34-ST for Sanitary Flange Mount. Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ Printed in U.S.A. Copyright 1998 Honeywell Inc.

2 Page 2 Features Description Choice of flush or extended diaphragm to match varying tank interface requirements. Direct digital integration with TDC 3000 X system provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies. Unique piezoresistive sensor automatically compensates input for temperature and static pressure. Added smart features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display. Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions. Models STF924 and STF932 are available with a flush or extended diaphragm with a flange that is always attached to the high pressure side of the body. All performance specifications for these models hold for ±100% of the upper range value so you can use them for either gaseous or liquid reference leg (open or closed tank) applications without regard to flange position. With a flush diaphragm model, the diaphragm is mounted flush with the gasket surface of a 3-inch, Class 150 or 300 ANSI flange. With an extended diaphragm model, the diaphragm is attached to a 2.86 inch (72.64 mm) dia stainless steel extension tube having standard extensions of 2, 4, or 6 inches (50, 101, or 152 mm). You may increase the effective dia of the extension tube to 3.75 inches(92.25 mm) by adding an optional sleeve. The extension tube is mounted to the gasket surface of either a 3 or 4-inch, Class 150 or 300 ANSI flange. Note that models STF924 and STF932 are also available in a 3-A Sanitary Flange Mount version designed for mounting on a sanitary tank spud with a 2 or 6-inch (50 or 152 mm) extension using a Ladish 4-inch Tri-Clamp. See Sanitary Mount Specification 34-ST for details. Models STF92F and STF93F are standard differential pressure transmitters with one of the normal process heads replaced by a 3- inch, Class 150 ANSI flange. For vented tank or gaseous reference leg applications, the flange is mounted on the high pressure side. For tanks with a liquid reference leg, the flange is mounted on the low pressure side. Either version is field convertible to the opposite side. The ST 3000 transmitter can replace any 4 to 20 milliampere output transmitter in use today, and operates over a standard two-wire system. The measuring means is a piezoresistive sensor which actually contains three sensors in one. It contains a pressure sensor, a temperature sensor, and a static pressure sensor. Microprocessorbased electronics provide higher span-turndown ratio, improved temperature and pressure compensation, and improved accuracy. Like other Smartline Transmitters, the ST 3000 features two-way communication between the operator and the transmitter through our SFC. You can connect the SFC anywhere that you can access the transmitter signal lines, and it provides the capabilities of transmitter adjustments and diagnostics from remote locations, such as the control room. The transmitter s body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the single-board electronics, which is isolated from an integral junction box. The singleboard electronics is replaceable and interchangeable with any other ST 3000 Series 900 or Series 100e model transmitter.

3 Page 3 Specifications Operating Conditions All Models Para Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage C F C F C F C F Ambient Temperature 25 ±1 77 ±2-40 to to to to to to 257 Meter Body Temperature 25 ±1 77 ±2-40 to 110* -40 to 230* -40 to to to to 257 Process Interface Temperature STF924, STF932 only 25 ±1 77 ±2-40 to 110** -40 to 230** -40 to to to to 257 Humidity %RH 10 to 55 0 to to to 100 Overpressure (Flange Rating) ANSI Class 150 psi bar ANSI Class 300 psi bar Vacuum Region - Minimum Pressure mmhg absolute inh2o absolute atmospheric atmospheric (short term ) 1 (short term ) Supply Voltage, Current, and Load Resistance Voltage Range: 10.8 to 42.4 Vdc at terminals Current Range: 3.0 to 21.8 ma Load Resistance: 0 to 1440 ohms (as shown in Figure 2) * For model STF932 with CTFE fill fluid, the rating is 15 to 110 C (5 to 230 F); for models STF92F and STF93F with CTFE fill fluid, the rating is 15 to 70 C (5 to 158 F). ** For model STF932 with CTFE fill fluid, the rating is 15 to 110 C (5 to 230 F). For CTFE fill fluid, the maximum temperature rating is 150 C (300 F). Short term equals 2 hours at 70 C (158 F)

4 Page = Operating Area Loop Resistance (ohms) NOTE: A minimum of 250 0hms of loop resistance is necessary to support communications. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. Also 45 volt operation is permitted if not an intrinsically safe installation Operating Voltage (Vdc) Figure 2 Supply voltage and loop resistance chart

5 Performance Under Rated Conditions* - Model STF924 (0 to 400 inh 2 O/1000 mbar) Para Upper Range Limit Minimum Span inh2o mbar inh2o mbar Description 400 (39.2 F/4 C is standard reference temperature for inh2o range.) Turndown Ratio 16 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Combined Zero and Span Static Pressure Effect per 1000 psi (70 bar) 34-ST Page 5 No limit except minimum span within ±100% URL. Specifications valid from 100% to + 100% URL. In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (25 inh2o), accuracy equals: 25 inh2o ± or ± mbar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (25 inh2o), accuracy equals: 25 inh2o ± or ± mbar In Analog Mode: ±0.2625% of span. For URV below reference point (), effect equals: ± or ± mbar In Digital Mode: ±0.25% of span. For span below reference point (), effect equals: ±0.25 or ± mbar In Analog Mode: ±0.50% of span. For URV below reference point (), effect equals: ± or ± mbar In Digital Mode: ±0.475% of span. For span below reference point (), effect equals: ± or ± mbar ±0.2125% of span. For URV below reference point (), effect equals: ± or ± mbar ±0.40% of span. For URV below reference point (), effect equals: ± or ± mbar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

6 Page 6 Performance Under Rated Conditions* - Model STF932 (0 to 100 psi/7 bar) Para Upper Range Limit Minimum Span psi bar psi bar Turndown Ratio 20 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Span Static Pressure Effect per 1000 psi (70 bar) Description No limit except minimum span within ±100% URL. Specifications valid from 100% to + 100% URL. In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± psi span psi or ± bar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± psi span psi or ± bar In Analog Mode: ±0.2625% of span. ± span psi or ± bar In Digital Mode: ±0.25% of span. ±0.25 span psi or ± bar In Analog Mode: ±0.50% of span. ± span psi or ± bar In Digital Mode: ±0.475% of span. ± span psi or ± bar ±0.2125% of span. ± span psi or ± bar ±0.40% of span. ± span psi or ± bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

7 Performance Under Rated Conditions* - Model STF92F (0 to 400 inh 2 O/25 mbar) Para Upper Range Limit Minimum Span inh2o mbar inh2o mbar Description 400 (39.2 F/4 C is standard reference temperature for inh2o range.) Turndown Ratio 16 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Combined Zero and Span Static Pressure Effect per 1000 psi (70 bar) 5 to +100% URL 34-ST Page 7 In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (25 inh2o), accuracy equals: 25 inh2o ± or ± mbar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (25 inh2o), accuracy equals: 25 inh2o ± or ± mbar In Analog Mode: ±0.1625% of span. For URV below reference point (), effect equals: ± or ± mbar In Digital Mode: ±0.15% of span. For URV below reference point (), effect equals: ±0.15 or ± mbar In Analog Mode: ±0.25% of span. For URV below reference point (), effect equals: ± or ± mbar In Digital Mode: ±0.225% of span. For URV below reference point (), effect equals: ± or ± mbar ±0.1625% of span. For URV below reference point (), effect equals: ± or ± mbar ±0.30% of span. For URV below reference point (), effect equals: ± or ± mbar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

8 Page 8 Performance Under Rated Conditions* - Model STF93F (0 to 100 psi/7 bar) Para Upper Range Limit Minimum Span psi bar psi bar Turndown Ratio 20 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Combined Zero and Span Static Pressure Effect per 1000 psi (70 bar) 5 to +100% URL Description In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± psi span psi or ± bar In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± psi span psi or ± bar In Analog Mode: ±0.1625% of span. ± span psi or ± bar In Digital Mode: ±0.15% of span. ±0.15 span psi or ± bar In Analog Mode: ±0.25% of span. ± span psi or ± bar In Digital Mode: ±0.225% of span. ± span psi or ± bar ±0.1625% of span. ± span psi or ± bar ±0.30% of span. ± span psi or ± bar *Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

9 Performance Under Rated Conditions - General for all Models Para Output (two-wire) Supply Voltage Effect Damping Time Constant CE Conformity (Europe) Description 34-ST Page 9 Analog 4 to 20 ma or DE digital communications mode. Optional HART electronics module available % span per volt. Adjustable from 0 to 32 seconds digital damping. 89/336/EEC, Electromagnetic Compatibility (EMC) Directive. Physical and Approval Bodies Para Barrier Diaphragms Material (Wetted) Gasket Ring Material (Wetted) Extension Tube Material (Wetted) Process Head and Adapter Flange Material Sanitary Flange Mount Process Head Gaskets Meter Body Bolting Mounting Flange STF924, STF932 Fill Fluid Electronic Housing Process Connections Wiring Mounting STF92F, STF93F All Models STF924, STF932 STF92F, STF93F 316L SS, Hastelloy C SS, Hastelloy C-276* 316 SS Description 316 SS, Carbon Steel (zinc-plated), Hastelloy C-276* All parts are 316 SS. Teflon is standard. Carbon Steel or 316 SS (NACE) bolts. Flush or Extended Diaphragm: Zinc Chromate plated Carbon Steel, 304 SS, or 316 SS. Sanitary Design: 316 SS 316 SS Silicone oil or CTFE (Chlorotrifluoroethylene) Epoxy-Polyester hybrid paint. Low Copper-Aluminum. Meets NEMA 4X (watertight) and NEMA 7 (explosion proof). Stainless steel optional. Process Head: 1/4-inch NPT; 1/2-inch NPT with adapter, standard option. Flange: 3 or 4-inch Class 150 or 300 ANSI; DN80-PN40 or DN100-PN40 DIN flange. Extended Diaphragm: 2, 4, or 6 inches (50, 101, 152 mm) long. Sanitary Flange Mount: 4-inch sanitary tank spud with Ladish 4-inch Tri-Clamp. See Specification 34-ST inch, Class 150 ANSI flange. Accepts up to 16 AWG (1.5 mm dia). See Figure 3 for typical flange mounting arrangement. Dimensions See Figures 4, 5, and 6 Net Weight STF924, STF932 Flush Model: 26.5 pounds (12 Kg) STF92F, STF93F 15.4 pounds (7 Kg) Approval Bodies Approved as explosion proof and intrinsically safe for use in Class I, Division 1, Groups A, B, C, D locations, and nonincendive for Class I, Division 2 Groups A, B, C, D locations. Approved EEx ia IIC T5 and EEx d IIC T6 per CENELEC standards; and Ex N II T5 per BS Series 900 with HC (HART) Compatibility is self certified for Zone 2, T5, maximum 42V/22 ma. * Flush design only.

10 Page 10 Attention: Dotted area indicates use with closed tank with gas reference leg. B A Maximum Level Variable Head H1 Gas Leg Reference Minimum Level LP SideVented to Atmosphere HP Side Mounted to Tank Figure 3 Typical mounting arrangement for flange mounted liquid level transmitter

11 Page 11 Reference Dimensions: millis inches Plug With Smart Removal Clearance for All Caps Without Without With Analog Optional s "T" /2-inch NPT SQ /4-inch NPT Optional external ground "B" Dia. "D" Dia. 45 Optional Adapter for 1/2-inch NPT "H" Dia Description "T" "D" Flange Dia. Bolt Hole "H"Dia Number Bolt Circle "B" Dia. 3-inch, ANSI Class inch, ANSI Class DIN DN80-PN inch, ANSI Class inch, ANSI Class DIN DN100-PN Figure 4 Approximate mounting dimensions for STF924 and STF932 flush diaphragm type

12 Page 12 Reference Dimensions: millis inches Plug With Smart Removal Clearance for All Caps Without Without With Analog Optional s 1/2-inch NPT 1/4-inch NPT Optional external ground "T" SQ "A" Dia. "B" Dia. "D" Dia. 45 Optional Adapter for 1/2-inch NPT "H" Dia "E" Description "T" "D" Flange Dia. Bolt Hole "H"Dia. Number Bolt Circle "A" Dia. (Optional) "B" Dia. Extension E E 2-inch E 4-inch E 6-inch 3-inch, ANSI Class inch, ANSI Class N/A DIN DN80-PN inch, ANSI Class inch, ANSI Class DIN DN100-PN NOTE: See Specification 34-ST for Sanitary Flange Mount version Figure 5 Approximate mounting dimensions for STF924 and STF932 extended diaphragm type

13 Page 13 Reference Dimensions: millis inches With Smart Removal Clearance for All Caps Without Without With Analog Plug Optional s Optional external ground 1/2-inch NPT Rotational Lock SQ Optional Adapter for 1/2-inch NPT "A" "T" Customer Supplied Flange and Hardware 45 Bolt Circle ID Bolt Holes Flange Dia "B" Dia Description "T" Flange Dia. Bolt Hole/Studs Dia Number Bolt Circle "A" "B" Dia. 3-inch, ANSI Class Figure 6 Approximate mounting dimensions for STF92F and STF93F pseudo flange type

14 Page 14 Reference Dimensions: millis inches With Smart Removal Clearance 45.7 for All Caps Without Without With Analog Plug Optional clamp connects transmitter and tank spud Optional external ground 1/2" NPT Optional s Rotational lock Optional tank spud is welded to tank wall /4" NPT or or Process tank wall Figure 7 Typical mounting dimensions for Flange-Mounted Liquid Level Transmitter with sanitary flange for 4-inch dia tank spud For Reference Only

15 Page 15 Options Ordering Information Mounting Bracket The angle mounting bracket is available in either zinc-plated carbon steel or stainless steel and is suitable for horizontal or vertical mounting on a two inch (50 milli) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for two inch (50 milli) pipe mounting. Indicating Meter Two integral options are available. An analog (option ME) is available with a 0 to 100% linear scale. The Smart Meter (option SM) provides an LCD display for both analog and digital output and can be configured to display pressure in pre-selected engineering units. * Lightning Protection A terminal block with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes is available. HART Protocol Compatibility (Option HC) An optional electronics module is available for the Series 900 that provides HART Protocol compatibility. Transmitters with the HART Option are compatible with the AMS System. (Contact your AMS Supplier if an upgrade is required.) Configuration of the HART Option transmitter is accomplished using a Universal HART Communicator. For full functionality the communicator must contain the Honeywell Device Description (DD). Contact your nearest Honeywell office or distributor for further information regarding this option. *NOTE: When used in conjunction with the HC Option the Smart Meter will display only 0 to 100%. Tagging (Option TG) Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost. Note that a separate nameplate on the body contains the serial number and body-related data. A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available. The number of characters for tagging includes spaces. Transmitter Configuration (Option TC) The factory can configure the transmitter linear/square root extraction, damping time, LRV, URV and mode (analog/digital) and enter an ID tag of up to eight characters and scratchpad information as specified. Custom Calibration and ID in Memory (Option CC) The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory. FOUNDATION Fieldbus (Future Option FF) Equips transmitter with FF protocol for use in kbit/s FF networks. See document 34-ST for additional information on ST 3000 Fieldbus transmitters. Specifications are subject to change without notice. (Note that specifications may differ slightly for transmitters manufactured before October 30, 1995.) Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Industrial Automation & Control N. Black Canyon Highway Phoenix, AZ In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL (954) In Europe: Honeywell PACE 1, Avenue du Bourget B-1140 Brussels, Belgium [32-2] In Asia: Honeywell Asia Pacific Inc. Room Sun Hung Kai Centre No. 30 Harbour Road Wanchai, Hong Kong In the Pacific: Honeywell Limited 5 Thomas Holt Drive North Ryde NSW 2113 Australia (61 2) Or, visit Honeywell on the World Wide Web at:

16 Page 16 Model Selection Guide 34-ST Instructions Select the desired Key Number. The arrow to the right marks the selection available. Make one selection from each table, I and II, using the column below the proper arrow. Select as many Table III options as desired (if no options are desired, specify 00). A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table IV. Key Number I II III (Optional) IV - _ - _ -, - XXXX KEY NUMBER Selection Availability Span 0-25 to inh 2 0/ to mbar Compound Characterized STF to psi/ to 0-7 bar Compound Characterized STF to inh 2 0/ to mbar STF92F 0-5 to psi/ to 0-7 bar STF93F TABLE I - METER BODY Vent/Drain Barrier Diaphragm Design Ref. Hd. Valve Diaphragms Plate Extension on Ref. Hd (wetted) (wetted) (wetted) 316 LSS 316 SS A Carbon* Hast C 316 SS W Steel Hast C Hast C B Flush 316 SS 316 LSS 316 SS E 316 SS Hast C 316 SS N/A X Hast C Hast C F Hast C Hast C Hast C Hast C J Materials Carbon* 316 LSS M Extended Steel Hast C N 316 SS 316 SS 316 LSS 316 SS 316 SS R Hast C S Carbon* 316 LSS A Pseudo Steel 316 SS Hast C N/A N/A B Flange 316 SS 316 LSS E Hast C F Sanitary Flange 316 SS 316SS 316 LSS 316 SS 316 SS Z w (3-A) Fill Fluid Silicone _ 1 _ (Meter Body & Flange) CTFE _ 2 _ Reference Head Flange 1/4" NPT High Pressure Side A Process Low Pressure Side C Connection 1/2" NPT (with Adapter) High Pressure Side H t t Low Pressure Side K t * Carbon Steel heads are zinc-plated.

17 Page 17 Model Selection Guide, continued STF9 Availability 24 2F TABLE II - FLANGE ASSEMBLY Selection 32 3F No Selection 0 3" ANSI Class 150 _ 1 _ y 3" ANSI Class 300 _ 2 _ y DN80-PN40 DIN Carbon _ 3 _ y 4" ANSI Class 150 Steel _ 4 _ 4" ANSI Class 300 (non-wetted) _ 5 _ DN100-PN40 DIN _ 6 _ 3" ANSI Class 150 _ A _ y Flange 3" ANSI Class 300 _ B _ y DN80-PN40 DIN 304 SS _ C _ y (ANSI Flanges have 4" ANSI Class 150 _ D _ AARH 4" ANSI Class 300 (non-wetted) _ E _ Surface Finish) DN100-PN40 DIN _ F _ 3" ANSI Class 150 _ H _ y 3" ANSI Class 300 _ J _ y DN80-PN40 DIN 316 SS _ K _ y 4" ANSI Class 150 _ L _ 4" ANSI Class 300 (non-wetted) _ M _ DN100-PN40 DIN _ N _ Pseudo Flange on Standard DP 3" ANSI Class 150 w/vent/drain (wetted) _ R _ 3" ANSI Class 150 w/o Vent/Drain _ P _ 3-A Sanitary Flange for 4" Ladish 316 SS _ S _ w Tri-Clamp (wetted) No Selection 0 w Gasket Ring 316 SS 1 g (wetted) Flush Design Hast C 2 g Extended Design 316 SS 5 v No Selection _ 0 _ Flush _ F _ h Dia Length 2.86 Inches 2 inches _ 1 _ v (for 3" or 4 " spud) 4 inches _ 2 _ v Extension 6 inches _ 3 _ v (wetted) 3.75 Inches 2 inches _ 5 _ v (optional for 4" spud) 4 inches _ 6 _ v 6 inches _ 7 _ v 4 Inch Nominal Sanitary 2 inches _ A _ w (for sanitary spud) 6 inches _ B _ w No Selection 0

18 Page 18 Model Selection Guide, continued STF9 Availability 24 2F TABLE III - OPTIONS Selection 32 3F None 00 Adapter Flange - 1/2" NPT St. Steel S1 c c b Adapter Flange - 1/2" NPT Hastelloy-C T1 c c Modified DIN Process Heads - 316SS DN z z 316 ST.ST. Electronics Housing with M20 Conduit Connections SH m m 1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC) A1 n n b 1/2" NPT to 3/4" NPT 316 SS Conduit Adapter A2 u u Lightning Protection LP Analog Meter (0-100 Even 0-10 Square Root) ME b Smart Meter SM 316SS (NACE) Bols and 304SS (NACE) Retaining Ring for Heads CR Custom Calibration and I.D. in Memory CC Transmitter Configuration TC Write Protection WP Local Zero and Span ZS b HART Protocol Compatible Electronics HC x x Stainless Steel Customer Wired-On Tag TG (4 lines, 28 characters per line, customer supplied information) Stainless Steel Customer Wired-On Tag (blank) TB Additional Warranty - 1 year W1 Additional Warranty - 2 years W2 b Additional Warranty - 3 years W3 Additional Warranty - 4 years W4 Clean Transmitter for Oxygen or Chlorine Service with Certificate 0X j j Over-Pressure Leak Test with F3392 Certificate TP Blind DIN SS Flanges Mounted with NACE Bolts B1 d d Calibration Test Report and Certificate of Conformance (F3399) F1 b Certificate of Conformance (F3391) F3 Certificate of Origin (F0195) F5 NACE Certificate (F0198) F7 o o Table III continued next page

19 Page 19 Model Selection Guide, continued STF9 Availability 24 2F TABLE III - OPTIONS (continued) Selection 32 3F Approval Body Approval Type Location or Classification Factory Explosion Proof Class I, Div. 1, Groups A,B,C,D Mutual Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Non-Incendive Class I, Div. 2, Groups A,B,C,D F1D3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G C1C3 Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X b (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. H2D5 (ATEX4) 80 o C, T6 at Tamb. 65 o C SA Intrinsically Safe Ex ia IIC T4 A0CA Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof/ EEx d IIC T6 CENELEC CENELEC Intrinsically Safe/ EEx ia IIC T5 E1D9 CENELEC Flame Proof/ EEx d IIC T6 CENELEC Intrinsically Safe/ EEx ia IIC T5 E1D8 f f CENELEC Flame Proof/ EEx d IIC T6 E1D3 CENELEC b No hazardous location approvals 9X Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D 1C Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G 2J Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Zone 2 Self-Declared Ex II 3 GD T (1) X (Europe) per 94/9/EC (1) T4 at Tamb. 93 o C, T5 at Tamb. 3N (ATEX4) 80 o C, T6 at Tamb. 65 o C SA Intrinsically Safe Ex ia IIC T4 4H a a (Australia) Non-Incendive Ex n IIC T6 (T4 with SM option) Flame Proof Ex d IIC T6 Flame Proof/ EEx d IIC T6 3A CENELEC LCIE Intrinsically Safe/ EEx ia IIC T5 CENELEC Flame Proof/ EEx d IIC T6 3D CENELEC TABLE IV Factory Identification XXXX

20 Page 20 Model Selection Guide, continued RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection b Select only one option from this group c I H, K d I E _ A, F _ A, R _ A, S _ A, X _ A, E _ C, F _ C III DN f III HC g I A, B, E, F, J, W, X h I M,N,R,S,Z II 5,, 0 j I _ 2 _ m III F1D3, C1C3, ZS n III F1D3, C1C3 o III CR or B1 t Select from Table III S1, T1 u III F1D3, C1C3 v I M, N, R, S w I, II Z - _ S0A _; Z - _ S0B _ x III A0CA, E1D9 y II _ 5 _, _ 6 _, _ 7 _ z I E _ A, F _ A, R _ A, S _ A, X _ A, E _ C, F _ C Note: See 13:ST-27 for Published Specials with pricing. See 13:ST-29 and User s Manual for part numbers. See 13:ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates, drawings and SPINS. See 13:ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values. To request a quotation for a non-published "special", fax RFQ to Marketing Applications. Industrial Automation and Control Honeywell Inc North Black Canyon Highway Phoenix, Arizona

LGP Design. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to

More information

Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 100 Gauge Pressure Models STG140 0 to 500 psi 0 to 35 bar / STG17L 0 to 3000 psi 0 to 210 bar STG14L 0 to 500 psi 0 to 35 bar / STG180 0 to 6000 psi 0 to 415 bar STG170

More information

URV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55

URV LRV. Smart Field Communicator. Can be ordered separately see specification 34-ST-03-55 ST 3000 Smart Transmitter Series 900 Differential Pressure Models STD924 0 to 400 inh 2 O 0 to 1,000 mbar STD930 0 to 100 psi 0 to 7,000 mbar STD974 0 to 3000 psi 0 to 210,000 mbar Function 34-ST-03-65

More information

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 900 Absolute Pressure Models STA922 0 to 780 mmhga 0 to 1,040 mbara STA940 0 to 500 psia 0 to 35 bara Function 34-ST-03-66 11/98 Specification and Model Selection Guide

More information

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 100 Differential Pressure Models STD110 0 to 10 inh2o 0 to 25 mbar STD120 0 to 400 inh2o 0 to 1,000 mbar STD125 0 to 600 inh2o 0 to 1,500 mbar STD130 0 to 100 psi 0 to

More information

LGP Design. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to

More information

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 100 Absolute Pressure Models STA122 0 to 780 mmhga 0 to 1,040 mbara STA140 0 to 500 psia 0 to 35 bara Function 34-ST-03-61 11/98 Specification and Model Selection Guide

More information

LGP Design. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55 ST 3000 Smart Transmitter Series 900 Models STD904 Differential 0 to 400 inh 2 O 0 to 1,000 mar STG90L Gauge 0 to 500 psi 0 to 35 ar Function Honeywell s STD904 and STG90L models offer an economical solution

More information

Specification and Model Selection Guide. Introduction 34-ST /04

Specification and Model Selection Guide. Introduction 34-ST /04 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to

More information

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04 ST 3000 Smart Transmitter Series 100 Gauge Pressure Models STG140/STG14L 0 to 500 psi 0 to 35 bar STG170/STG18L 0 to 3000 psi 0 to 210 bar STG180/STG18L 0 to 6000 psi 0 to 415 bar STG19L 0 to 10000 psi

More information

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06 ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models STD924 0 to 400 inh 0 to 1,000 mbar STD930 0 to 100 psi 0 to 7,000 mbar STD974 0 to 3000 psi 0 to 210,000 mbar Introduction 34-ST-03-65

More information

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5 SFC Smart Field Communicator Model STS103 Description The hand-held SFC Smart Field Communicator is a battery-powered device which establishes secure two-way communications between Honeywell Smart and

More information

SET. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

SET. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 100 Remote Diaphragm Seals Models STR12D 0-10 to 0-400 inh 2 O 0-25 to 0-1000 mbar STR13D 0-5 to 0-100 psid 0-0.35 to 0-7 bar STR14G 0-5 to 0-500 psig 0-0.35 to 0-35 bar

More information

ST 3000 Smart Transmitter

ST 3000 Smart Transmitter ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models STR93D 0 to 100 psid 0 to 7 bar STR94G 0 to 500 psig 0 to 35 bar 11/98 Specification and Model Selection Guide Function Honeywell s ST

More information

ST 3000 Fieldbus Transmitter Series 100 Models

ST 3000 Fieldbus Transmitter Series 100 Models ST 3000 Fieldbus Transmitter Series 100 Models The ST 3000 Fieldbus Transmitter is designed as an enhancement to smart or analog transmitters and may use the existing transmitter signal lines for power

More information

Specification and Model Selection Guide 34-ST /2003

Specification and Model Selection Guide 34-ST /2003 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to

More information

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications 34-XY-03-22 November 2010 Introduction Building upon the tremendously successful ST 3000 series transmitter line;

More information

Specification and Model Selection Guide. Introduction 34-XY /13/07

Specification and Model Selection Guide. Introduction 34-XY /13/07 XYR6000 Wireless Transmitter Gauge Pressure Models STGW944 0 to 500 psi 0 to 35 STGW94L 0 to 500 psi 0 to 35 STGW974 0 to 3000 psi 0 to 210 STGW97L 0 to 3000 psi 0 to 210 STGW98L 0 to 6000 psi 0 to 415

More information

XYR 6000 Wireless Transmitter Absolute Pressure Model. Specification and Model Selection Guide. Introduction 34-XY /13/07

XYR 6000 Wireless Transmitter Absolute Pressure Model. Specification and Model Selection Guide. Introduction 34-XY /13/07 XYR 6000 Wireless Transmitter Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara 34-XY-03-23 8/13/07 Specification and Model Selection Guide Introduction Building upon the tremendously successful

More information

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications 34-XY-03-24 November 2010 Introduction Building upon the tremendously successful ST 3000 series transmitter line; Honeywell brings

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models. Specification and Model Selection Guide. Introduction 34-ST /08

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models. Specification and Model Selection Guide. Introduction 34-ST /08 ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models STF128 0 to 400 inh 2 O 0 to 1000 mar STF132 0 to 100 psi 0 to 7 ar STF12F 0 to 400 inh 2 O 0 to 1000 mar STF13F 0 to 100 psi 0 to

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma 34-XY-03-30 September 2009 Specification and Model Selection Guide Introduction Building

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications 34-XY-03-23 March 2012 Introduction Building upon the tremendously successful ST 3000 series

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to

More information

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters XYR6000 Wireless Temperature Transmitter Series WT400 STTW820,830,840,850 with direct mounted T/C or RTD STTW400 only with input for T/C s (3 max) or RTD s (2 max) Introduction 34-XY-03-29 8/14/07 Specification

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models Specifications

ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models Specifications ST 3000 Smart Transmitter Series 100 Flange Mounted Liquid Level Models Specifications 34-ST-03-63 August 2011 Introduction In 1983, Honeywell introduced the first Smart Pressure Transmitter the ST 3000.

More information

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f A New Generation Of Pressure Transmitters -AII V5 ECNO : 610f A New Transmitter at the edge of Technology - - - - - -AII V5 2 - Approvals Fieldbus (FF) Protocols TM Hart /Fuji (bilingual) PROFIBUS The

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric

More information

Specification and Model Selection Guide. Introduction 34-ST /07

Specification and Model Selection Guide. Introduction 34-ST /07 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 ar STG94L 0 to 500 psi 0 to 35 ar STG974 0 to 3000 psi 0 to 210 ar STG97L 0 to 3000 psi 0 to 210 ar STG98L 0 to 6000

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters e-front runners A New Generation of Transmitters SeriesAII/CII ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric has

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS Product Data Sheet Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0

More information

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications 34-XY-03-33 February 2010 Model STXW500 - Up to 3 discrete inputs) Introduction Building upon the tremendously successful

More information

Series Smart Pressure Transmitter

Series Smart Pressure Transmitter www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that

More information

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries. SmartLine Non-Contact Radar Level Meter Technical Datasheet 34-VF-03-19 September 2009 Specification The Universal Radar Solution The SmartLine Non-Contact Radar Level Meter (FMCW) is for level measurement

More information

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /08

ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /08 ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models STD94 0 to 400 inho 0 to 1,000 mar STD930 0 to 100 psi 0 to 7,000 mar STD974 0 to 3000 psi 0 to 10,000 mar Introduction 34-ST-03-65

More information

Preface WBPEEUI110504A0

Preface WBPEEUI110504A0 Preface This publication is for the use of technical personnel responsible for the installation, calibration, operation, maintenance, and repair of the Type PTSD Platinum Standard Smart Pressure Transmitter.

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

SmartLine Wireless Flange Mounted Pressure Transmitter Specification

SmartLine Wireless Flange Mounted Pressure Transmitter Specification SmartLine Wireless Flange Mounted Pressure Transmitter Specification 34-SW-03-04, December 2018 Series 800 model: STFW828 0 to 400 in H2O 0 to 1,000 mbar Series 700 Model: STFW724 0 to 400 in H2O 0 to

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

ST 3000 Smart Transmitter Series 900 Absolute Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /07

ST 3000 Smart Transmitter Series 900 Absolute Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /07 ST 3000 Smart Transmitter Series 900 Asolute Pressure Models STA922/STA92L 0 to 780 mmhga STA940/STA94L 0 to 500 psia Introduction 0 to 1,040 mara 0 to 35 ara 34-ST-03-66 3/07 Specification and Model Selection

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

SmartLine Wireless Pressure Gauge Transmitter Specification

SmartLine Wireless Pressure Gauge Transmitter Specification SmartLine Wireless Pressure Gauge Transmitter Specification Introduction SmartLine Wireless Pressure continues the evolution of Honeywell s wireless transmitter product offering and provides the latest

More information

I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement

I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement Product Specifications I/A Series Electronic Pressure Transmitters with 4 to 20 ma Analog Output for Absolute and Gauge Pressure Measurement PSS 2A-1C13 C IAP20/IGP20 TRANSMITTER IAP10/IGP10 TRANSMITTER

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

11A Series Absolute Pressure Transmitters

11A Series Absolute Pressure Transmitters Product Specifications 11A Series Absolute Pressure Transmitters PSS 2B-1A1 A 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER In 11A Series Transmitters, the reliable force-balance d/p

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in: oxy.iq Panametrics Oxygen Transmitter Applications An oxygen transmitter for use in: Glove box purge and leak detection Natural gas Semiconductor wafer machines Coating process machines Membrane air separators

More information

IAP10/IGP10 TRANSMITTER STRUCTURE CODES 52, 53, 60-63, D5, D6, S5, S6, SH, AND SJ

IAP10/IGP10 TRANSMITTER STRUCTURE CODES 52, 53, 60-63, D5, D6, S5, S6, SH, AND SJ FIELD DEVICES - PRESSURE Product Specifications Logo PSS 2A-1C13 C Models IAP10, IGP10, IAP20, and IGP20 I/A Series Electronic Absolute and Gauge Pressure Transmitters with 4 to 20 ma Analog Output IAP20/IGP20

More information

Accutech DP20. Wireless differential pressure field unit

Accutech DP20. Wireless differential pressure field unit Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional

More information

FIELD DEVICES PRESSURE

FIELD DEVICES PRESSURE FIELD DEVICES PRESSURE Product Specifications Models IAP10, IGP10, IAP20, and IGP20 I/A Series Electronic Absolute and Gauge Pressure Transmitters with 4 to 20 ma Analog Output PSS 2A-1C13 C IAP20/IGP20

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

Compact Orifice Flow Meter

Compact Orifice Flow Meter Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure

More information

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement Doc. No. : C3100-E05A FM APPROVED Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of

More information

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application Specification sheet 6T EN Series Pressure Transmitters Model 6ES gauge/absolute with direct mount seal for pulp & paper application Base accuracy : ±.7% Reliable inductive sensing system coupled with the

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

STT 3000 Smart Temperature Transmitter

STT 3000 Smart Temperature Transmitter STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

Wireless Transmitter Series XYR 6000 Series 100 Gauge Pressure Models Specifications

Wireless Transmitter Series XYR 6000 Series 100 Gauge Pressure Models Specifications Wireless Transmitter Series XYR 6000 Series 100 Gauge Pressure Models Specifications 34-XY-03-46 August 2012 STGW14L 0 to 500 psi 0 to 35 bar STGW17L 0 to 3,000 psi 0 to 210 bar STGW18L 0 to 6,000 psi

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span PERFORMANCE SPECIFICATIONS Reference Accuracy (1) Specifications Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

PTG series Smart Pressure Transmitter

PTG series Smart Pressure Transmitter No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page

More information

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /2002

ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models. Specification and Model Selection Guide. Introduction 34-ST /2002 ST 3000 Smart Transmitter Series 900 Remote Seals Models STR93D 0 to 100 psid 0 to 7 bar STR94G 0 to 500 psig 0 to 35 bar Introduction 34-ST-03-57 10/2002 Specification and Model Selection Guide In 1983,

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000

More information

Wireless Base Radio. Wireless Transmitters

Wireless Base Radio. Wireless Transmitters XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information