Measuring Non-linear Amplifiers

Size: px
Start display at page:

Download "Measuring Non-linear Amplifiers"

Transcription

1 Measuring Non-linear Amplifiers Transceiver Components & Measuring Techniques MM3 Jan Hvolgaard Mikkelsen Radio Frequency Integrated Systems and Circuits Division Aalborg University 27

2 Agenda Non-linear measurement Signal combining Hybrids Circulators The spectrum analyzer Resolution Bandwidth/Phase noise Internally Generated Distortion Video Filter Filter selectivity Input attenuation Dynamic Range / Dynamic Range Graph Digital Spectrum Analyzers Differences Advantages/Disadvantages Power measurement -2-

3 How is IP n measured? Depending of the type of IP n measurement different combinations of input signals are required. The IP n performance of a specific device may be measured in different ways and using different input signal conditions. Remember to measure the device using the same input conditions as used for the receiver or transmitter planning. Single-tone versus modulated single-tone versus two-tone. Signal generators may be used to supply two sine-waves of equal amplitude but different frequencies. The resulting output spectrum may be measured using a spectrum analyzer. DUT -3- Spectrum Analyzer

4 Signal generator non-idealities Just as our linear amplifier proves to be non-linear when tested, signal generators also display non-ideal behavior. Signal generators are active circuits. The generated signal contains harmonics. A certain frequency error (usually small for SOA generators). Phase noise from the Local Oscillator. If the isolation between two distinct generators is too low the generators will also generate intermodulation products in addition to signal harmonics (as well as source pulling etc.). Combining circuits must be utilized to provide for adequate isolation. Attenuators. Circulators / Isolators. Hybrids. -4-

5 -5- Combining / Signal Isolation Circulators or isolators use ferromagnetic materials to provide non-reciprocal signal transmission. Hybrids combine paths with different electric lengths in a way that the output is a combination of the input signals while isolating the two input ports. 9 degree hybrids (Quadrature). 8 degree hybrids. = S C = 2 j S H = 2 j j j j S H

6 -6- Combining/Signal Isolation Non-5Ω impedances at the DUT input affect performance of both hybrids and circulators/isolators. Even for a perfect hybrid, non-5ω impedances have an impact as seen from the resulting S-matrix. L ; 2 Z Z Z Z j L L L L L L L H + = Γ Γ Γ Γ Γ Γ = S 5 Ω 5 Ω Z L 5 Ω = 2 j S H

7 -7- Combining/Signal Isolation Non-5Ω impedances at the DUT input affect performance of both hybrids and circulators/isolators. For a perfect circulator the S-matrix now becomes: L ; Z Z Z Z L L L L C + = Γ Γ Γ = S = S C 5 Ω ZL 5 Ω Now that some of the important details for the input side is understood it is time to consider the output also. Only once the test set-up is fully know is it possible to ensure optimum settings for any given DUT.

8 What is inside a spectrum analyzer? The analyzer relocates the input to lower frequency where it estimates the resulting power. A ramp sweeping LO is used to evaluate different frequencies and plot the power at these. Pre select Input attn. Mixer IF amp IF filter Detector VCO Reference XO Ramp Generator Display y-axis y-axis Video Filter -8- x-axis x-axis

9 What is inside a spectrum analyzer? - II To achieve a high frequency resolution very sharp filters are needed. Some analyzers have resolutions in the order of -Hz.. and such a level of resolution is NOT achieved at 6GHz. Instead several mixer stages are used to down convert the input signal to more manageable frequencies. y-axis y-axis x-axis x-axis -9-

10 Limitations of the spectrum analyzer The spectrum analyzer (SA) is in principle an RF receiver and as such it adds both noise and distortion to the input signal. The SA also has a finite selectivity which also affect performance. Such non-ideal effects set a limit on a number of important parameters. Signal frequency spacing. Minimum/Maximum input power (Dynamic Range). Maximum amplitude difference. Spectrum analyzers can be adjusted in a variety of ways which provides a trade-off situation. Measurement sweep time is traded for resolution and the same goes for the noise. --

11 SA limitations frequency resolution Consider the case where a single-tone input signal signal is being feed to the SA. As the LO changes in frequency so vil the mixing product of the input signal. Due to the finite band width of the IF filter output power is going to be detected at a frequency range around the input frequency. As a result the characteristics of the IF filter is reflected on the display of the SA. --

12 SA limitations frequency resolution - II The IF filter with the lowest bandwidth consequently sets the limitation on the achievable frequency resolution. The finite IF filter bandwidth smears the signal across a frequency band and could eventually case signals to disappear. Noise floor and LO phase noise set a limit to the amplitude sensitivity. IF filter BW Noise Floor Phase noise Noise Floor Phase noise if we are lucky.. -2-

13 SA limitations frequency resolution - III For equal-amplitude signals requirements are not to strict.. but for different amplitudes the resolution is extremely important. Resolution bandwidth (RBW) is the user parameter that determines the frequency resolution of the SA. By changing the RBW setting it is possible to change the IF bandwidth of the SA. Not only does this affect the frequency masking performance it also affects the noise floor level of the SA. RBW too high -3-

14 SA limitations frequency resolution - IV When working with signals of different amplitudes we need to determine what RBW is allowable. To characterize the different RBW settings a term called bandwidth selectivity (or shape factor) is used. Shape factor is the ratio between the 3dB bandwidth and the 6dB bandwidth. For analog filters a shape factor of :5 is typical. For digital filters much sharper filters are possible and typical shape factors are around :5. When trying to determine the allowable RBW we need to know the shape factor of the band limiting IF filter. -4-

15 SA limitations frequency resolution - V Using the example from the Agilent application note.. what RBW is required to resolve two signals with a 4kHz offset in frequency and a 3dB offset in amplitude assuming a shape factor of :? With amplitude (power) in a log scale we assume that there is a linear relation between the 3dB and the 6dB 3dB frequencies of the IF filter. We may hence determine the attenuation of the filter at the given offset using the following formula: f BW 3dB offset ATToffset = 3 db 2 DIFF3 db> 6dB BW6dB BW3dB 2 2 4kHz -5-

16 SA limitations frequency resolution - VI Using a 3kHz filter as a first guess we can calculate the attenuation as follows: 3kHz 4kHz ATT db 2 4 khz = 3 57dB = 2. 5dB 33kHz 3kHz 2 2 This is clearly not sufficient to resolve a 3dB difference and we need to go for a lower RBW.. khz for instance: khz 4kHz ATT khz 3dB 2 4 = 57dB = 42. 9dB khz khz 2 2 According to this a khz RBW is sufficient when we want to resolve a 3dB difference at the 4kHz offset. As an example lets assume an actual dbm input signal: PMeas = Pactual + Pleak = mw + 5.2μW =. 22dBm -6-

17 SA limitations frequency resolution - VII When illustrated graphically the effect of the two RBW settings (3kHz and khz) becomes very clear. 3kHz khz -7-

18 Digital Spectrum Analyzers Clearly, the shape factor has a major impact on the resolution performance of the analyzer. This is partly why most modern analyzers use digital LF/baseband processing.. remember the typical shape factor of :5. The block diagram of a digital SA does not differ significantly from the block diagram for an analog analyzer shown earlier. Input attn. Mixer Pre select IF filter IF amp IF ADC Frq. Synth DSP OCXO -8- CRT Display Ethernet GPIB Harddisk

19 Digital Spectrum Analyzers The down-converted input signal is normally sampled at IF signal and subsequently I/Q down-converted in the digital domain. A clear benefit from this is that perfect I/Q balance results. If the analyzer uses both I and Q branches for its signal processing it is referred to as a Vector Signal Analyzer (VSA). VSAs can analyze the signal using both amplitude and phase which is especially interesting when doing modulation measurements. I(n) A + 2 ( n) = I( n) Q( n ) 2 NCO Filter Coefficients 9 Q(n) -9-

20 Digital Spectrum Analyzers There are a number of good reasons that speak in favor of the digital analyzers. Going from analog to digital means better control over many aspects of the detection. Phase information can be extracted. Filters can be controlled much more efficiently. DSPs can control many of the spectrum analyzer s internal functions (such as input attenuation). There is however one very important effect to consider for digital spectrum analyzers that is not seen in their analog counterparts. Instead of using a continuous ramp signal (analog) the local oscillator is stepped over the frequency span. For a newer spectrum analyzer (FSIQ) the number of steps along the frequency axis is for instance

21 Digital Spectrum Analyzers This inherently limited frequency resolution need to be considered very carefully when doing measurements. For example: When measuring over a frequency span of 2MHz the 5 frequency points imply that the distance between measurement frequency points is 4kHz. This can easily cause signals to fall between the measurement points which clearly leads to wrong conclusions. Great care must therefore be taken to choose the span/rbw correctly. Provided that the equipment is operated correctly the use of digital signals provides for other advantages. Averaging: Digitizing the signal allows us to average over a number of measurements. Post-analysis: Data may also be transferred to PC for any kind of postprocessing. -2-

22 Averaging the video filter Averaging is not limited to digital analyzers only, as most analog analyzer include a video filter (Video averaging is another thing (/n)). The video filter is a lowpass filter (band limited video amplifier) that is applied after power detection. The video filter smoothes out uncorrelated noise making it easier to detect weak signals. The degree of averaging is a function of the ratio between video bandwidth and resolution bandwidth (RBW). The optimal video filter bandwidth is normally <% of the RBW but this may result in unacceptably long sweep times. -22-

23 SA limitations dynamic range As the SA operates as a receiver it also displays a limited dynamic range performance. Overloading the SA therefore causes distortion inside the analyzer. Most prone to this are the mixers in the super-heterodyne chain. The input power to the active parts of the SA may be reduced using the internal attenuator. For very high input power levels this may not be sufficient.. note that if presented with a sufficiently high input power the input stage of the SA may be destroyed. -23-

24 SA limitations dynamic range - II The specific use of input attenuation depends on the specific analyzer. In some cases the attenuation is reflected directly on the display. For most spectrum analyzers the IF gain is set-up to automatically compensate for changes in the input attenuation. As a direct result the signal level remains stable while the noise floor on the other hand is raised with increased attenuation. The increase corresponds to change in input att. -24-

25 SA limitations dynamic range - III No matter what approach is used for the input attenuation it affects the dynamic range an hence helps determine the maximum detectable amplitude difference. Different definitions exist: Measurement range (noise floor maximum input power). Mixer compression (noise floor mixer CP db ). Second/Third harmonic (noise floor the input power where the second/third order harmonics are equal to the noise floor) (SFDR). A graphical method can be used to determine the optimal input level for each bandwidth setting Optimum Dynamic Range. The parameters needed for this may all be obtained from the spectrum analyzer data sheet: Noise floor at a certain bandwidth (displayed average noise level (DANL)). Third order intercept point (TOI). Second order intercept point (SOI). -25-

26 Power level rel. to desired signal SA limitations dynamic range - IV To see how the resulting dynamic range performance of an analyzer may be determined consider the following case: DANL: -2 dbm/hz. TOI: +5 dbm. SOI: +3 dbm. Based on these numbers we need to be able to determine the performance that we can expect from our spectrum analyzer set-up. Only when we know the details of the performance can we set-up the measurement to obtain the optimum performance for a specific measurement dbc 2 dbc 4 dbc 6 dbc 8 dbc 8 dbm 6 dbm 4 dbm 2 dbm dbm Desired Signal Input

27 Power level rel. to desired signal Powerlevelrel.todesiredsignal SA limitations dynamic range - V First step: Add the noise level: X = DANL, Y = dbc. If the desired signal is equal to the noise level the difference between noise and desired signal is dbc. The noise has a slope of -: For each db increase in the desired signal the difference between the desired signal and the noise floor increases by db. For higher or lower RBW the noise floor moves on the graph. Increasing/decreasing the BW by a factor of N raises/lowers the DANL by a factor of log(n). For a DANL of -2dBm/Hz and a RBW of khz the resulting noise is given as -2dBm/Hz + 4dB = -8dBm/kHz. dbc 2 dbc 4 dbc 6 dbc 8 dbc 8 dbm 6 dbm khz khz 4 dbm 2 dbm dbm Desired Signal Input -27-

28 Power level rel. to desired signal SA limitations dynamic range - VI The second and third order effects are then added to the graph. When the input power equals the TOI, the third order product is equal to the fundamental. The slope of the SOI and TOI lines are and 2 respectively: Second order effects increase by 2dB for each db increase of the desired signal which gives a net increase db. dbc 2 dbc 4 dbc The intersection between the noise curve and the distortion curves denotes the optimum input power for the SA. Here noise and SOI set the limit. DR For each db increase in the desired signal the third order intermodulation increases by 3dB net increase of 2dB. 6 dbc 8 dbc dbm Desired Signal Input -28-

29 Power level rel. to desired signal SA limitations dynamic range - VII For intermodulation measurements with low frequency separation phase noise can become the dominant factor in determining the dynamic range. For instance, consider the case where two tones have a frequency separation of khz and the phase noise level of the analyzer in question, at khz offset, is -5dBc. This means that the dynamic range of the measurement will never be more than 5 db dbc 2 dbc 4 dbc 6 dbc 8 dbc Considering only noise and distortion our graphical model indicates a dynamic range performance of approx. 6dB. Here the phase noise places the lower limit by restricting the dynamic range to 5dB. 8 dbm 6 dbm 4 dbm 2 dbm TOI TOI dbm Desired Signal Mixer PN PN

30 Measurement uncertainty The previous dynamic range graph was calculated based on the fact that the Dynamic Range is limited by noise on one hand, and spurious responses on the other hand. The upper limit of the Dynamic Range is determined by the input level where the spurious products reach the noise floor. However, this will not enable us to measure an externally generated product accurately when the fundamental input power is equal to the optimum input power shown on slide

31 Measurement uncertainty - II The measurement uncertainty when trying to discern one sinusoid signal from another (at the same frequency) is give as: ΔdB = 2 log(± where d is the relative difference between the two signals in db. For a maximum uncertainty of db the amplitude difference must be at least 8dB! This also influences the dynamic range considerations. d / 2 ) -3-

32 Rules of thumb... All active devices produce IMD: Use attenuators when combining outputs from signal generators. Another option is to use circulators or hybrids. Analyzers are active devices so watch the input levels: Use the attenuator to suppress high power signals. Adjust RBW and VBW to obtain sufficient dynamic range: Consider your measurement requirements. Look in data sheets for the analyzer and determine the set-up required for optimum performance (sweep time vs. dynamic range fx.). The most important rule of them all.. Find out what your spectrum analyzer can and cannot do. Read the bloody manual!!! -32-

33 Power measurements The spectrum analyzer is not a true power meter as it measures amplitude voltages. The voltages are subsequently converted to dbm assuming a 5Ω reference impedance. A power meter measures the dissipated power directly. Different methods are used to perform this power measurement: Thermistors. Thermocouples. Square law detection is used in some power meters (although this is not a true power meter). -33-

34 Power meter block diagram RF power is converted to DC power and measured in the power meter. More accurate than spectrum analyzer (although newer high-end spectrum/signal analyzers have sub-db accuracy). Combine the use of a spectrum analyser with the use of a power meter. After combining input signal generators you should calibrate the power readings of the generators by measuring the actual power at the input of your DUT. -34-

Understanding RF and Microwave Analysis Basics

Understanding RF and Microwave Analysis Basics Understanding RF and Microwave Analysis Basics Kimberly Cassacia Product Line Brand Manager Keysight Technologies Agenda µw Analysis Basics Page 2 RF Signal Analyzer Overview & Basic Settings Overview

More information

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz Application Note Overview This application note describes accuracy considerations

More information

Receiver Architecture

Receiver Architecture Receiver Architecture Receiver basics Channel selection why not at RF? BPF first or LNA first? Direct digitization of RF signal Receiver architectures Sub-sampling receiver noise problem Heterodyne receiver

More information

Measuring ACPR of W-CDMA signals with a spectrum analyzer

Measuring ACPR of W-CDMA signals with a spectrum analyzer Measuring ACPR of W-CDMA signals with a spectrum analyzer When measuring power in the adjacent channels of a W-CDMA signal, requirements for the dynamic range of a spectrum analyzer are very challenging.

More information

A year and a half after the first introduction of the PXA, Agilent is now introducing the world s highest performance mmw signal analyzer in April

A year and a half after the first introduction of the PXA, Agilent is now introducing the world s highest performance mmw signal analyzer in April 1 This presentation is intended to be a beginning tutorial on signal analysis. Vector signal analysis includes but is not restricted to spectrum analysis. It is written for those who are unfamiliar with

More information

8 Hints for Better Spectrum Analysis. Application Note

8 Hints for Better Spectrum Analysis. Application Note 8 Hints for Better Spectrum Analysis Application Note 1286-1 The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope provides

More information

8 Hints for Better Spectrum Analysis. Application Note

8 Hints for Better Spectrum Analysis. Application Note 8 Hints for Better Spectrum Analysis Application Note 1286-1 The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope provides

More information

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note 02 Keysight Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note 1. Introduction

More information

RF Fundamentals Part 2 Spectral Analysis

RF Fundamentals Part 2 Spectral Analysis Spectral Analysis Dec 8, 2016 Kevin Nguyen Keysight Technologies Agenda Overview Theory of Operation Traditional Spectrum Analyzers Modern Signal Analyzers Specifications Features Wrap-up Page 2 Overview

More information

Utilizzo del Time Domain per misure EMI

Utilizzo del Time Domain per misure EMI Utilizzo del Time Domain per misure EMI Roberto Sacchi Measurement Expert Manager - Europe 7 Giugno 2017 Compliance EMI receiver requirements (CISPR 16-1-1 ) range 9 khz - 18 GHz: A normal +/- 2 db absolute

More information

Specification RIGOL. 6 Specification

Specification RIGOL. 6 Specification Specification RIGOL 6 Specification This chapter lists the specifications and general specifications of the analyzer. All the specifications are guaranteed when the following conditions are met unless

More information

PARAMETER CONDITIONS TYPICAL PERFORMANCE Operating Supply Voltage 3.1V to 3.5V Supply Current V CC = 3.3V, LO applied 152mA

PARAMETER CONDITIONS TYPICAL PERFORMANCE Operating Supply Voltage 3.1V to 3.5V Supply Current V CC = 3.3V, LO applied 152mA DESCRIPTION LT5578 Demonstration circuit 1545A-x is a high linearity upconverting mixer featuring the LT5578. The LT 5578 is a high performance upconverting mixer IC optimized for output frequencies in

More information

High Dynamic Range Receiver Parameters

High Dynamic Range Receiver Parameters High Dynamic Range Receiver Parameters The concept of a high-dynamic-range receiver implies more than an ability to detect, with low distortion, desired signals differing, in amplitude by as much as 90

More information

Chapter 5 Specifications

Chapter 5 Specifications RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.

More information

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed SPECTRUM ANALYZER Introduction A spectrum analyzer measures the amplitude of an input signal versus frequency within the full frequency range of the instrument The spectrum analyzer is to the frequency

More information

APPLICATION NOTE 3942 Optimize the Buffer Amplifier/ADC Connection

APPLICATION NOTE 3942 Optimize the Buffer Amplifier/ADC Connection Maxim > Design Support > Technical Documents > Application Notes > Communications Circuits > APP 3942 Maxim > Design Support > Technical Documents > Application Notes > High-Speed Interconnect > APP 3942

More information

Overcoming Mixer Measurement Challenges

Overcoming Mixer Measurement Challenges Overcoming Mixer Measurement Challenges October 10, 2002 presented by: Robb Myer Dave Ballo Today we will be looking at overcoming measurements challenges associated with frequency translating devices

More information

ADI 2006 RF Seminar. Chapter II RF/IF Components and Specifications for Receivers

ADI 2006 RF Seminar. Chapter II RF/IF Components and Specifications for Receivers ADI 2006 RF Seminar Chapter II RF/IF Components and Specifications for Receivers 1 RF/IF Components and Specifications for Receivers Fixed Gain and Variable Gain Amplifiers IQ Demodulators Analog-to-Digital

More information

RF Receiver Hardware Design

RF Receiver Hardware Design RF Receiver Hardware Design Bill Sward bsward@rtlogic.com February 18, 2011 Topics Customer Requirements Communication link environment Performance Parameters/Metrics Frequency Conversion Architectures

More information

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators Application Note 02 Keysight 8 Hints for Making Better Measurements Using RF Signal Generators - Application Note

More information

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

DSA800. No.1 RIGOL TECHNOLOGIES, INC. No.1 DSA800 9 khz to 1.5 GHz Frequency Range Typical -135 dbm Displayed Average Noise Level (DANL) -80 dbc/hz @10 khz offset Phase Noise Total Amplitude Uncertainty

More information

Agilent ESA-L Series Spectrum Analyzers

Agilent ESA-L Series Spectrum Analyzers Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are

More information

ECE 440L. Experiment 1: Signals and Noise (1 week)

ECE 440L. Experiment 1: Signals and Noise (1 week) ECE 440L Experiment 1: Signals and Noise (1 week) I. OBJECTIVES Upon completion of this experiment, you should be able to: 1. Use the signal generators and filters in the lab to generate and filter noise

More information

Understanding Mixers Terms Defined, and Measuring Performance

Understanding Mixers Terms Defined, and Measuring Performance Understanding Mixers Terms Defined, and Measuring Performance Mixer Terms Defined Statistical Processing Applied to Mixers Today's stringent demands for precise electronic systems place a heavy burden

More information

Agilent N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned

More information

RF/IF Terminology and Specs

RF/IF Terminology and Specs RF/IF Terminology and Specs Contributors: Brad Brannon John Greichen Leo McHugh Eamon Nash Eberhard Brunner 1 Terminology LNA - Low-Noise Amplifier. A specialized amplifier to boost the very small received

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1455A 5MHZ TO 1600MHZ HIGH LINEARITY DIRECT QUADRATURE MODULATOR LTC5598 DESCRIPTION

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1455A 5MHZ TO 1600MHZ HIGH LINEARITY DIRECT QUADRATURE MODULATOR LTC5598 DESCRIPTION LTC5598 DESCRIPTION Demonstration circuit 1455A is a high linearity direct quadrature modulator featuring the LTC5598. The LTC 5598 is a direct I/Q modulator designed for high performance wireless applications,

More information

DSA700 Series Spectrum Analyzer

DSA700 Series Spectrum Analyzer DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.

More information

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5668R (NI 5668R) vector signal analyzer (VSA)

More information

A Guide to Calibrating Your Spectrum Analyzer

A Guide to Calibrating Your Spectrum Analyzer A Guide to Calibrating Your Application Note Introduction As a technician or engineer who works with electronics, you rely on your spectrum analyzer to verify that the devices you design, manufacture,

More information

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface SPECIFICATIONS PXIe-5645 Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface Contents Definitions...2 Conditions... 3 Frequency...4 Frequency Settling Time... 4 Internal Frequency Reference...

More information

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has

More information

Satellite Communications: Part 4 Signal Distortions & Errors and their Relation to Communication Channel Specifications. Howard Hausman April 1, 2010

Satellite Communications: Part 4 Signal Distortions & Errors and their Relation to Communication Channel Specifications. Howard Hausman April 1, 2010 Satellite Communications: Part 4 Signal Distortions & Errors and their Relation to Communication Channel Specifications Howard Hausman April 1, 2010 Satellite Communications: Part 4 Signal Distortions

More information

M980xA Series PXIe Vector Network Analyzer

M980xA Series PXIe Vector Network Analyzer DATA SHEET M980xA Series PXIe Vector Network Analyzer 2/4/6-port, 9 khz to 20 GHz Drive Down the Size of Test M9800A 9 khz to 4.5 GHz M9801A 9 khz to 6.5 GHz M9802A 9 khz to 9 GHz M9803A 9 khz to 14 GHz

More information

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc. SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter Datasheet 2017 SignalCore, Inc. support@signalcore.com P RODUCT S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

3250 Series Spectrum Analyzer

3250 Series Spectrum Analyzer The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS 3250 Series Spectrum Analyzer > Agenda Introduction

More information

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth IBRATION PROCEDURE PXIe-5646 Reconfigurable 6 GHz Vector Signal Transceiver with 200 MHz Bandwidth This document contains the verification and adjustment procedures for the PXIe-5646 vector signal transceiver.

More information

GA GHz. Digital Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com

More information

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N529A Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS

More information

RECOMMENDATION ITU-R SM Method for measurements of radio noise

RECOMMENDATION ITU-R SM Method for measurements of radio noise Rec. ITU-R SM.1753 1 RECOMMENDATION ITU-R SM.1753 Method for measurements of radio noise (Question ITU-R 1/45) (2006) Scope For radio noise measurements there is a need to have a uniform, frequency-independent

More information

GA GHz. Digital Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 678A 40MHZ TO 900MHZ DIRECT CONVERSION QUADRATURE DEMODULATOR

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 678A 40MHZ TO 900MHZ DIRECT CONVERSION QUADRATURE DEMODULATOR DESCRIPTION QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 678A LT5517 Demonstration circuit 678A is a 40MHz to 900MHz Direct Conversion Quadrature Demodulator featuring the LT5517. The LT 5517 is a direct

More information

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...

More information

Agilent N9343C Handheld Spectrum Analyzer (HSA)

Agilent N9343C Handheld Spectrum Analyzer (HSA) Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Agilent N9343C Handheld Spectrum Analyzer (HSA) 1 MHz to 13.6 GHz (tunable to 9 khz) Data Sheet Field

More information

Advances in RF and Microwave Measurement Technology

Advances in RF and Microwave Measurement Technology 1 Advances in RF and Microwave Measurement Technology Chi Xu Certified LabVIEW Architect Certified TestStand Architect New Demands in Modern RF and Microwave Test In semiconductor and wireless, technologies

More information

Configuration of PNA-X, NVNA and X parameters

Configuration of PNA-X, NVNA and X parameters Configuration of PNA-X, NVNA and X parameters VNA 1. S-Parameter Measurements 2. Harmonic Measurements NVNA 3. X-Parameter Measurements Introducing the PNA-X 50 GHz 43.5 GHz 26.5 GHz 13.5 GHz PNA-X Agilent

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR 304/1 DATA SHEET Frequency range: 300 khz to 3.2 GHz Measured parameters: S11, S21, S12, S22 Dynamic range of transmission measurement magnitude: 135 db Measurement time

More information

Measuring 3rd order Intercept Point (IP3 / TOI) of an amplifier

Measuring 3rd order Intercept Point (IP3 / TOI) of an amplifier Measuring 3rd order Intercept Point (IP3 / TOI) of an amplifier Why measuring IP3 / TOI? IP3 is an important parameter for nonlinear systems like mixers or amplifiers which helps to verify the quality

More information

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand Advanced VNA Measurements Agenda Overview of the PXIe-5632 Architecture SW Experience Overview of VNA Calibration

More information

HF Receiver Testing: Issues & Advances (also presented at APDXC 2014, Osaka, Japan, November 2014) Adam Farson VA7OJ Copyright 2014 North Shore Amateur Radio Club NSARC HF Operators HF RX Testing 1 HF

More information

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer

PXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer SPECIFICATIONS PXIe-5668 14 GHz and 26.5 GHz Vector Signal Analyzer These specifications apply to the PXIe-5668 (14 GHz) Vector Signal Analyzer and the PXIe-5668 (26.5 GHz) Vector Signal Analyzer with

More information

Spectrum Analyzer Training

Spectrum Analyzer Training Spectrum Analyzer Training Roberto Sacchi Application Engineer roberto_sacchi@agilent.com Page 1 Agenda Introduction Overview: What is Signal Analysis? What Measurements are available? Theory of Operation

More information

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer CALIBRATION PROCEDURE NI PXIe-5665 3.6 GHz and 14 GHz RF Vector Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5665 (NI 5665) RF vector signal analyzer

More information

Agilent Back to Basics. Spectrum Analysis Back to Basics. Presented by: Michel Joussemet

Agilent Back to Basics. Spectrum Analysis Back to Basics. Presented by: Michel Joussemet Agilent Back to Basics Spectrum Analysis Back to Basics Presented by: Michel Joussemet Aerospace and Defense Symposium 2007 EuMw 2007 Agilent Workshop Agenda Introduction Overview: What is Signal Analysis?

More information

Agilent Spectrum Analysis Basics. Application Note 150

Agilent Spectrum Analysis Basics. Application Note 150 Agilent Spectrum Analysis Basics Application Note 150 Table of Contents Chapter 1 Introduction.......................................................4 Frequency domain versus time domain.......................................4

More information

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D Swept-tuned spectrum analyzer Gianfranco Miele, Ph.D www.eng.docente.unicas.it/gianfranco_miele g.miele@unicas.it Reference level and logarithmic amplifier The signal displayed on the instrument screen

More information

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World

More information

Digital Spectrum Analyzer GA40XX Series

Digital Spectrum Analyzer GA40XX Series GA4062/GA4032 9kHz~1.5GHz GA4033/GA4063 9kHz~3GHz GA4064 9kHz~7.5GHz Product Overview GA40XX series is a small size, light weight, cost-effective portable spectrum analyzer to meet your all the RF application

More information

Improving Amplitude Accuracy with Next-Generation Signal Generators

Improving Amplitude Accuracy with Next-Generation Signal Generators Improving Amplitude Accuracy with Next-Generation Signal Generators Generate True Performance Signal generators offer precise and highly stable test signals for a variety of components and systems test

More information

Application Note 106 IP2 Measurements of Wideband Amplifiers v1.0

Application Note 106 IP2 Measurements of Wideband Amplifiers v1.0 Application Note 06 v.0 Description Application Note 06 describes the theory and method used by to characterize the second order intercept point (IP 2 ) of its wideband amplifiers. offers a large selection

More information

RF, Microwave & Wireless. All rights reserved

RF, Microwave & Wireless. All rights reserved RF, Microwave & Wireless All rights reserved 1 Non-Linearity Phenomenon All rights reserved 2 Physical causes of nonlinearity Operation under finite power-supply voltages Essential non-linear characteristics

More information

TestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board

TestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board Page 1 of 16 ========================================================================================= TestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board =========================================================================================

More information

Some Aspects Regarding the Measurement of the Adjacent Channel Interference for Frequency Hopping Radio Systems

Some Aspects Regarding the Measurement of the Adjacent Channel Interference for Frequency Hopping Radio Systems Some Aspects Regarding the Measurement of the Adjacent Channel Interference for Frequency Hopping Radio Systems PAUL BECHET, RADU MITRAN, IULIAN BOULEANU, MIRCEA BORA Communications and Information Systems

More information

Guide to Spectrum Analysis

Guide to Spectrum Analysis Guide to Spectrum Analysis www.anritsu.com CONTENTS INTRODUCTION... 4 Frequency Domain / Time Domain... 4 SPECTRUM ANALYZERS... 7 Types... 7 Basic Operation... 8 Characteristics... 9 Frequency Range...

More information

Interference Analysis and Spectrum Monitor Seminar

Interference Analysis and Spectrum Monitor Seminar Interference Analysis and Spectrum Monitor Seminar Handheld RF & Microwave Instruments Andrew Benn Business Development Manager Agilent Technologies Wednesday 12 th October 2011 1 Agilent Technologies,

More information

Spectrum Analyzer FSL

Spectrum Analyzer FSL Specifications Version 02.00 Spectrum Analyzer FSL August 2005 Specifications Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified

More information

SSB0260A Single Sideband Mixer GHz

SSB0260A Single Sideband Mixer GHz Single Sideband Mixer.2 6. GHz FEATURES LO/RF Frequency: Input IP3: Sideband Suppression: LO Leakage: LO Power: DC Power:.2 6. GHz +32 dbm -45 dbc (Typical) -5 dbm (Typical) -1 to +1 dbm +5V @ 5 ma DESCRIPTION

More information

R&S FSWP Phase Noise Analyzer Specifications

R&S FSWP Phase Noise Analyzer Specifications R&S FSWP Phase Noise Analyzer Specifications Data Sheet Version 06.00 CONTENTS Definitions... 4 Specifications... 5 Frequency... 5 Phase noise measurements... 5 Phase noise sensitivity with R&S FSWP-B61

More information

Keysight Streamline Series USB Vector Network Analyzer P500xA 2-port, 9 khz to 20 GHz

Keysight Streamline Series USB Vector Network Analyzer P500xA 2-port, 9 khz to 20 GHz Keysight Streamline Series USB Vector Network Analyzer P500xA 2-port, 9 khz to 20 GHz Compact Form. Zero Compromise. P5000A 9 khz to 4.5 GHz P5001A 9 khz to 6.5 GHz P5002A 9 khz to 9 GHz P5003A 9 khz to

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Measurement Procedure for Noise Power Ratio

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Measurement Procedure for Noise Power Ratio ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 119 2006 Measurement Procedure for Noise Power Ratio NOTICE The Society of Cable Telecommunications Engineers

More information

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz Datasheet The LNS is an easy to use 18 GHz synthesizer that exhibits outstanding phase noise and jitter performance in a 3U rack mountable chassis.

More information

Appnote - Realtime Spectrum Analyzer vs Spectrum Analyzer

Appnote - Realtime Spectrum Analyzer vs Spectrum Analyzer Appnote - Realtime Spectrum Analyzer vs Spectrum Analyzer Today the RF industry has to face more and more the open question, how to transport the data from my test device (DUT) to different receiver spots

More information

PTX-0350 RF UPCONVERTER, MHz

PTX-0350 RF UPCONVERTER, MHz PTX-0350 RF UPCONVERTER, 300 5000 MHz OPERATING MODES I/Q upconverter RF = LO + IF upconverter RF = LO - IF upconverter Synthesizer 10 MHz REFERENCE INPUT/OUTPUT EXTERNAL LOCAL OSCILLATOR INPUT I/Q BASEBAND

More information

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N9342C Handheld Spectrum Analyzer (HSA) Agilent N9342C Handheld Spectrum Analyzer (HSA) Data Sheet Field testing just got easier The Agilent N9342C handheld spectrum analyzer (HSA) is more than easy-to-use its measurement performance gives you

More information

RADIO RECEIVERS ECE 3103 WIRELESS COMMUNICATION SYSTEMS

RADIO RECEIVERS ECE 3103 WIRELESS COMMUNICATION SYSTEMS RADIO RECEIVERS ECE 3103 WIRELESS COMMUNICATION SYSTEMS FUNCTIONS OF A RADIO RECEIVER The main functions of a radio receiver are: 1. To intercept the RF signal by using the receiver antenna 2. Select the

More information

Lab Exercise PN: Phase Noise Measurement - 1 -

Lab Exercise PN: Phase Noise Measurement - 1 - Lab Exercise PN: Phase Noise Measurements Phase noise is a critical specification for oscillators used in applications such as Doppler radar and synchronous communications systems. It is tricky to measure

More information

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc. SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module Datasheet 2015 SignalCore, Inc. support@signalcore.com SC5306B S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview The Agilent Technologies test system is designed to verify the performance of the

More information

SHF Communication Technologies AG

SHF Communication Technologies AG SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23 Aufgang D 2277 Berlin Marienfelde Germany Phone ++49 30 / 772 05 0 Fax ++49 30 / 753 0 78 E-Mail: sales@shf.biz Web: http://www.shf.biz Tutorial

More information

Measurements 2: Network Analysis

Measurements 2: Network Analysis Measurements 2: Network Analysis Fritz Caspers CAS, Aarhus, June 2010 Contents Scalar network analysis Vector network analysis Early concepts Modern instrumentation Calibration methods Time domain (synthetic

More information

R&S R&S ZVL-K1 Spectrum Analysis Options Software Manual

R&S R&S ZVL-K1 Spectrum Analysis Options Software Manual R&S R&S ZVL-K1 Spectrum Analysis Options Software Manual 1303.6573.42 05 Test and Measurement Software Manual This Software Manual describes the following options for the R&S ZVL: R&S ZVL-K1, stock no.

More information

Spectrum Analyzers 2680 Series Features & benefits

Spectrum Analyzers 2680 Series Features & benefits Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level

More information

Why/When I need a Spectrum Analyzer. Jan 12, 2017

Why/When I need a Spectrum Analyzer. Jan 12, 2017 Why/When I need a Jan 12, 2017 Common Questions What s the difference of Oscilloscope and Spectrum Analysis Almost all Oscilloscope has FFT for a spectrum view, why I need a spectrum analyzer? When shall

More information

TSEK02: Radio Electronics Lecture 8: RX Nonlinearity Issues, Demodulation. Ted Johansson, EKS, ISY

TSEK02: Radio Electronics Lecture 8: RX Nonlinearity Issues, Demodulation. Ted Johansson, EKS, ISY TSEK02: Radio Electronics Lecture 8: RX Nonlinearity Issues, Demodulation Ted Johansson, EKS, ISY RX Nonlinearity Issues: 2.2, 2.4 Demodulation: not in the book 2 RX nonlinearities System Nonlinearity

More information

PLANAR 814/1. Vector Network Analyzer

PLANAR 814/1. Vector Network Analyzer PLANAR 814/1 Vector Network Analyzer Frequency range: 100 khz 8 GHz Measured parameters: S11, S12, S21, S22 Wide output power range: -60 dbm to +10 dbm >150 db dynamic range (1 Hz IF bandwidth) Direct

More information

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc. GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals Copyright 2001 Agilent Technologies, Inc. Agenda: Power Measurements Module #1: Introduction Module #2: Power Measurements Module #3:

More information

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! On-line curator: Glenn Robb This document is for FREE distribution only!

More information

Low voltage LNA, mixer and VCO 1GHz

Low voltage LNA, mixer and VCO 1GHz DESCRIPTION The is a combined RF amplifier, VCO with tracking bandpass filter and mixer designed for high-performance low-power communication systems from 800-1200MHz. The low-noise preamplifier has a

More information

Understanding Level Accuracy specifications and techniques in Spectrum Analysers.

Understanding Level Accuracy specifications and techniques in Spectrum Analysers. Understanding Level Accuracy specifications and techniques in Spectrum Analysers. Anritsu Spectrum Analyser roadshow. Feb 2018 Agenda Measurement fundamentals and uncertainties Amplitude level accuracy

More information

Techniques for Characterizing Spurious Signals

Techniques for Characterizing Spurious Signals Techniques for Characterizing Spurious Signals October 21, 2014 Riadh Said Product Manager Microwave and Communications Division Keysight Technologies Our Goals today Review the sweep time equation to

More information

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent 8560 EC Series Spectrum Analyzers Data Sheet Agilent 8560 EC Series Spectrum Analyzers Data Sheet Agilent 8560EC 30 Hz to 2.9 GHz Agilent 8561EC 30 Hz to 6.5 GHz 1 Agilent 8562EC 30 Hz to 13.2 GHz Agilent 8563EC 30 Hz to 26.5 GHz Agilent 8564EC 30

More information

350MHz, Ultra-Low-Noise Op Amps

350MHz, Ultra-Low-Noise Op Amps 9-442; Rev ; /95 EVALUATION KIT AVAILABLE 35MHz, Ultra-Low-Noise Op Amps General Description The / op amps combine high-speed performance with ultra-low-noise performance. The is compensated for closed-loop

More information

Development of high cost performance signal analyzer MS2830A -044/045

Development of high cost performance signal analyzer MS2830A -044/045 Development of high cost performance signal analyzer MS2830A -044/045 Yuji Kishi, Shuichi Matsuda, Koichiro Tomisaki, Kozo Yokoyama, Yoshiaki Yasuda, Tsukasa Yasui, Kota Kuramitsu [Summary] We have developed

More information

TRANSCOM Manufacturing & Education

TRANSCOM Manufacturing & Education www.transcomwireless.com 1 G6 Vector Signal Generator Overview G6 Vector Signal Generator is a high performance vector signal generator. It can generate arbitrary wave signal, continuous wave signal, common

More information

Glossary of VCO terms

Glossary of VCO terms Glossary of VCO terms VOLTAGE CONTROLLED OSCILLATOR (VCO): This is an oscillator designed so the output frequency can be changed by applying a voltage to its control port or tuning port. FREQUENCY TUNING

More information

SmartSpice RF Harmonic Balance Based RF Simulator. Advanced RF Circuit Simulation

SmartSpice RF Harmonic Balance Based RF Simulator. Advanced RF Circuit Simulation SmartSpice RF Harmonic Balance Based RF Simulator Advanced RF Circuit Simulation SmartSpice RF Overview Uses harmonic balance approach to solve system equations in frequency domain Well suited for RF and

More information

Budgeting Harmonics for ZigBee Front-End Modules

Budgeting Harmonics for ZigBee Front-End Modules APPLICATION NOTE Budgeting Harmonics for ZigBee Front-End Modules Introduction The growth of low-power, cost-effective wireless radio systems is driving more applications to use the ZigBee communication

More information

DSA800 RIGOL TECHNOLOGIES, INC.

DSA800 RIGOL TECHNOLOGIES, INC. DSA800 All-Digital IF Technology 9 khz - 1.5 GHz Frequency Range Up to -135dBm Displayed Average Noise Level (DANL) -80dBc/Hz @ 10kHz Oset Phase Noise Total Amplitude Uncertainty < 1.5dB 100Hz Minimum

More information

TESTING METHODS AND ERROR BUDGET ANALYSIS OF A SOFTWARE DEFINED RADIO By Richard Overdorf

TESTING METHODS AND ERROR BUDGET ANALYSIS OF A SOFTWARE DEFINED RADIO By Richard Overdorf TESTING METHODS AND ERROR BUDGET ANALYSIS OF A SOFTWARE DEFINED RADIO By Richard Overdorf SDR Considerations Data rates Voice Image Data Streaming Video Environment Distance Terrain High traffic/low traffic