An Interesting Use of Bausch and Lomb s KeraSoft IC Lens
|
|
- Carol Clark
- 6 years ago
- Views:
Transcription
1 An Interesting Use of Bausch and Lomb s KeraSoft IC Lens Nate Schlotthauer, OD 2012 Michigan College of Optometry Cornea and Contact Lens Resident Introduction: The KeraSoft IC lens, introduced to the United States by Bausch and Lomb, hit the US market in early January of this year. Although just recently brought to the United States, it has been utilized successfully in Europe for several years. KeraSoft IC is a customizable soft lens design for the healthy management of keratoconus and most other irregular corneal conditions. 1,2 It is made exclusively in Contamac s Definitive (Efrofilcon A) Silicone Hydrogel material, which has a water content of 74%, Dk of 60 and is replaced quarterly. 1,2,3 One of the hallmark concepts of the KeraSoft IC design is that the patient does not need to discontinue their current lens modality prior to being fit. 1,2 In the past, patients with suspected induced corneal warpage secondary to contact lenses were instructed to discontinue lens wear for a given period of time before being fit with new lenses in order to achieve the most appropriate fit. 4,5 In the case of patients with irregular corneas, best corrected visual acuity is often significantly better with contact lenses than with spectacles and discontinuing contact lens wear for any significant length of time is not always a realistic option. 4 The draping effect and the no-tear-lens principle utilized by the KeraSoft IC design allows for the cornea to normalize and maintain acceptable vision while wearing the lens, resulting in the patient retaining vision and comfort throughout the entire corneal rehabilitation process. 1,2 Most patients who are fit with the KeraSoft IC lens have corneal irregularity associated with a disease condition or a surgical procedure. 1,2 If these patients are experiencing secondary corneal warpage from their previous contact lenses, once the secondary corneal warpage is normalized they will still have an irregular corneal profile and can benefit from the level of visual acuity and comfort provided by the KeraSoft IC lens design. In the case of a patient who has normal corneas but has developed secondary corneal warpage from long term Gas Permeable (GP) contact lens wear, the KeraSoft IC design can be a tremendous tool in the transition from one lens modality to another, as the patient s cornea is able to normalize without having to discontinue lens wear. 2,4,5 This was exactly the case for a patient seen here at the University Eye Center at the Michigan College of Optometry. Case Report: A twenty-eight year old female patient presented to the University Eye Center at the Michigan College of Optometry with a chief complaint of significant glare with her GP lenses in and spectacle blur
2 post removal of her GP lenses. The patient reported the glare and spectacle blur occurring over the past five years with increasing severity in the past year. The patient is a high myope and has a twenty year history of GP lens wear. The patient reported the blur to be severe enough that spectacle wear outside the house was not an option due to feeling unsafe with her level of visual acuity. The patient has been instructed for multiple years to limit the length of GP lens wearing time, but has not been able to discontinue for any significant length of time due to her work and classroom schedule. Her latest GP lenses had base curves of 7.45mm OU, 10.0mm diameters OU and powers of sph OD and sph OS. Her best corrected visual acuities through her lenses were consistent from her past exams at 20/25+1 OD and 20/25-1 OS with plano over-refractions OU. Both lenses were in good condition with acceptable fluorescein patterns and movement OU. However, both lenses rested superior-temporally on the cornea. Upon removal of the GPs, subjective refraction yielded x 045 OD with a visual acuity of 20/30-1 and x135 OS and 20/30-2 visual acuity. The patient reported clearer visual acuity through this refraction versus her most recent spectacle Rx. Corneal topography was performed OU due to the probability of corneal warpage secondary to her long history of GP lens wear. The patient s baseline topographies can be seen below. The topographies show the patient s limbus-to-limbus corneal astigmatism being disrupted inferior nasal OU. The flat profile along with the large diameter of the high-minus GP lenses allow for excessive lid attachment resulting in the lenses being held superiorly. The abbreviation in the corneal astigmatism results from the peripheral curves of the lens flattening the cornea while being held in a superior position. The area that appears to be steepening inferior nasal is not actually steepening, but is
3 the termination of the corneal astigmatism outside of where the edge of the lens sits. This warpage of the cornea further promotes the lenses to rest in the observed superior temporal position OU. The patient was fit into Bausch and Lomb s KeraSoft IC lens using the fitting set and the supplied corneal profile fitting guidelines. Best stable visual acuity was achieved with the 8.6 BC lens OU but the lens exhibited unstable movement and mild erratic rotation, thus a one-steep periphery was ordered OU. Lens powers ordered were x 050 OD yielding 20/20 and x 123 OS yielding 20/20-1. Upon dispensing the KeraSoft IC lenses, the patient reported equal or better visual acuity than with her current GP lenses with improved comfort. She was sent home with the lenses and scheduled to follow up after one month of wear to evaluate the changes in the amount of corneal irregularity. Upon returning after a month of wear, the patient reported mild reduced comfort and increased lens movement upon blink, but the lenses still maintained acceptable visual acuity. Slit lamp evaluation of the lenses revealed the lenses to be sitting slightly inferior with mild variable rotation OU. The lenses were removed and corneal topography was performed. The one month results can be seen below. The one month topographies show a normalization of the corneal astigmatism OU. Both corneas display regular bowtie astigmatic patterns in comparison to the baseline topographies taken one month prior. Spectacle refraction was performed at this visit and revealed x055 OD yielding of 20/20-1 and x120 OS yielding 20/25+1. The patient reported seeing much clearer with this new Rx than her current spectacles. It was decided to order Art Optical s Intelliwave Toric custom soft lenses instead of continuing with the KeraSoft IC design due to the corneas displaying regular astigmatism on topography. Intelliwave trials were ordered for the patient in the Definitive
4 material with base curves of 8.2 OU, diameters of 14.5mm OU and powers x055 OD and x120 OS. The patient was instructed to continue wearing the KeraSoft IC lenses till the Intelliwave trials were received. Upon dispensing, the Intelliwave Toric lenses fit well OU. They displayed zero to minimal rotation and the patient was seeing 20/20-1 OD and 20/25 OS with plano to minimal over-refractions OU. The patient reported excellent comfort and vision through these lenses and was excited to try them in real world conditions. The lenses were dispensed and the patient was scheduled to come back for a progress check at one month. After one month of wear the patient reported consistent non-fluctuating vision with the Intelliwave Toric lenses. She reported better vision OD than OS but had noted the same with her GP lenses as well. Overall, the patient was very happy with the comfort and vision of the lenses and was excited to get a pair of spectacles that could be worn without spectacle blur upon removal of her contact lenses. Discussion: The KeraSoft IC design is intended to be used for any type of corneal irregularity. 1,2 Induced corneal warpage in this case definitely constituted corneal irregularity. 4,5 The corneal warpage had been occurring for several years resulting from the patient having a twenty year history of GP lens wear. A patient with this level of myopia is much more comfortable in contact lenses than spectacles therefore discontinuing CL wear for any length of time long enough to significantly decrease the corneal warpage was not a feasible option. 4,5 That being said, the fluorescein patterns with the patients GP lenses were appropriate and well aligned. However, the fit was based off the irregular cornea and not her regular non-contact lens induced corneal profile. The patient had tried other soft lens designs in the past with limited success as the lack of tear lens and corneal irregularity decreased her vision to an unacceptable level, hence the continued use of GP lenses. As stated before, the KeraSoft IC design can be fit on an irregular cornea without any wash-out period from previous lens wear. Any change in corneal irregularity that occurs while wearing the KeraSoft IC lens will be masked by the draping effect of the lens and can be addressed while ordering the next lens if the change is dramatic and detracts from the fit and visual acuity. 1,2,3 In the case of our patient, her cornea normalized to a regular astigmatic pattern over the course of one month of lens wear and was able to be re-fit into a conventional custom soft-toric design. The KeraSoft IC design being replaced quarterly should give adequate corneal rehabilitation time within the life span of one set of lenses and it can then be decided to continue with the KeraSoft IC design or switch to different lens design per patient situation. Conclusion: The flexibility of the KeraSoft IC design adapting to changing corneal profile is a very beneficial tool for practitioners. If a patient s current lens modality is not serving them well but they cannot discontinue lens wear and still maintain functionality in their daily life, the KeraSoft IC design can fill
5 that niche, and do so very well. The arena of specialty contact lenses is evolving very rapidly with advances in lens design and materials. It is a very exciting time to be a contact lens practitioner. References: 1. Bausch & Lomb Incorporated ART Optical Contact Lens, Inc Contamac Jinabhai, A., O Donnell, C., Radhakrishnan, H. Changes in refraction, ocular aberrations, and corneal structure after suspending rigid gas-permeable contact lens wear in keratoconus May 31(5): Tsai, P.S., Dowidar, A., Naseri, A., McLeod, S.D. Predicting time to refractive stability after discontinuation of rigid contact lens wear before refractive surgery. J Cataract Refract Surg November (30):
Fitting Manual Use with kerasofttraining.com
Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft
More informationFitting Manual Use with
Fitting Manual Use with The KeraSoft IC Lens for and Other Irregular Corneas The KeraSoft IC is a front surface asphere or aspheric toric prism ballasted lens with balanced overall thickness and wavefront
More informationIrregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide
Irregular Cornea ROSE K2 Soft TM Practitioner s Fitting Guide ROSE K2 Soft Applications Design ROSE K2 Soft is a daily wear soft lens for irregular corneas. ROSE K2 Soft is a 3 month replacement lens when
More informationFITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT
Keratoconus Nipple Cone Irregular Cornea Post Graft PRACTITIONER S FITTING GUIDE NIPPLE CONE IRREGULAR CORNEA POST GRAFT Four lens designs... One simple systematic approach to fitting Featuring Easy-to-fit
More informationULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS
ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS FITTING SET PARAMETERS The Standard Fitting Set is available with 8 x 14.50mm diameter lenses comprising: 6 x STD periphery Base Curve
More informationULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS
ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS DIAMETER & PERIPHERY GUIDE KeraSoft Thin s increased flexibility improves drapage over the peripheral cornea. This reduces the need
More informationIntroducing a lens that can take your scleral fitting to a higher plane.
Introducing a lens that can take your scleral fitting to a higher plane. Alden Optical s newest specialty lens has arrived: Zenlens, a mini-scleral, fully vaulting lens co-designed with Jason Jedlicka,
More informationCONTACT LENSES FOR KERATOCONUS & ALL IRREGULAR CORNEAS
CONTACT LENSES FO KEATOCONUS & ALL IEGULA CONEAS Technical Fitting Guide HYDOGEL www.kerasoft.co.uk KeraSoft IC Technical Fitting Guide Introduction The KeraSoft IC is a soft contact lens designed to fit
More informationShowcasing the Innovative Lens Design Portfolio that will Maximize Your Patient s Vision. Carri Russell, FCLSA, COT
Showcasing the Innovative Lens Design Portfolio that will Maximize Your Patient s Vision Carri Russell, FCLSA, COT Family business that was established in 1976 Headquarters in Dallas/Ft. Worth, Texas Long
More informationDESIGNED FOR SUCCESS...GUARANTEED TO FIT
This is a supplement to the main Flexlens fitting guide and does not contain all the warnings, precautions and directions for use found in the main fitting guide. Please refer to the main fitting guide
More informationFITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near
FITTING GUIDE Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near P R O G R E S S I V E The unique advanced-technology Duette hybrid contact lenses are
More informationfamily of lens designs fitting guide ICD is Exclusively Manufactured In
TM family of lens designs fitting guide ICD is Exclusively Manufactured In paragon 1 Select Initial Diagnostic Lens: Identify the Corneal Condition Normal Depth Eyes Normal Shapes Median Flat KReading
More informationCorneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals
Contact Lens Management of the Challenging Patient Disclosures: Alcon Bausch + Lomb SpecialEyes Valley Contax Vistakon Contact Lens Challenges Matthew J. Lampa, OD, FAAO lampa@pacificu.edu Challenge: Getting
More informationIntroducing an enlightened scleral lens designed specifically for regular corneas.
ZEN TM RC scleral lenses Introducing an enlightened scleral lens designed specifically for regular corneas. NEW ZEN RC ALL THE BENEFITS OF ZENLENS SCLERAL LENSES IN A SMALLER DIAMETER. The Zen RC lens
More informationG.P. MULTIFOCAL LENSES: A FITTING WORKSHOP
G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP Susan J. Gromacki, OD, MS, FAAO, FSLS Daniel G. Fuller, OD, FAAO, FSLS Cornea, Contact Lenses and Refractive Technologies Section The American Academy of Optometry
More informationWhat s a Corneal GP Lens?
Slide 1 What s a Corneal GP Lens? Richard Dorer NCLEC Blanchard Contact Lens Inc. 800-367-4009 x 131 richarddorer@gmail.com www.blanchardlab.com Slide 2 Endorsements I am a paid representative and consultant
More informationSiesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.
o r t h o k er a t o l o g y Training + Certification Guide Bringing eye care professionals the finest quality, custom GP lens designs. 800-792-1095 tfoptics.com Training and Certification Corneal Shape
More informationIntroduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.
Features Optimum Control and Results for High Myopia Hyperbolic Treatment Zones for Maximum Flattening Dual Aspheric Reverse and Alignment Zones for Improved Lens Centering Topographical / Empirical /
More informationThe soft approach to RGPs
CET CONTINUING EDUCATION & TRAINING Sponsored by 1 CET POINT The soft approach to RGPs Part 3: don t let torics put you in a spin 46 Mark Tomlinson BSc (Hons), MCOptom, FBDO (Hons) Most practitioners acknowledge
More informationMultifocal Contact Lenses. Steps for Success. Disclosures. Patient Selection. Presbyopic Soft Contact Lenses: Options for Success
Disclosures Outside Consultant Presbyopic Soft Contact Lenses: Options for Success Precilens Coopervision Research Funds Bausch and Lomb Brooke Messer, OD, FAAO, FSLS Cornea and Contact Lens Institute
More informationTORIC AND MULTIFOCAL GP AND SCL PRESCRIBING Edward S. Bennett OD, MSEd, FAAO
1 2 3 4 5 6 1 TORIC AND MULTIFOCAL GP AND SCL PRESCRIBING Edward S. Bennett OD, MSEd, FAAO l Dr. Bennett is a consultant to the Contact Lens Manufacturers Association SOFT TORICS: Good Candidates l Astigmatic
More informationSOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009
BIOMEDICS 55 (ocufilcon D) BIOMEDICS 55 Toric (ocufilcon D) BIOMEDICS 55 Multifocal (ocufilcon D) SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE PRACTITIONER FITTING
More informationThe War against Corneal Warpage
Page 1 of 5 I-site Amsterdam Netherlands i-site@netherlens.com Home Archive April 2010 Downloads The War against Corneal Warpage Key words: Corneal Warpage, Corneal Topography, Soft Lens Fit, (R)GP lens
More informationcase report Scleral lens fit based on OCT data
Page 1 of 5 I-site Amsterdam Netherlands i-site@netherlens.com Home Archive September 2009 Downloads case report Scleral lens fit based on OCT data Key words: scleral lens, ocular coherence tomography,
More informationExperience with correcting myopia with different types of contact lenses
Experience with correcting myopia with different types of contact lenses Edward BENNETT Refer this article as: Bennett, E., Experience with correcting myopia with different types of contact lenses, Points
More informationCorrecting Astigmatism with Contact Lenses John M. Laurent, OD, PhD William J. Benjamin, OD, PhD
Correcting Astigmatism with Contact Lenses John M. Laurent, OD, PhD William J. Benjamin, OD, PhD Photo: Annie Chang, OD, and Dawn Lam, OD. Before we start... Accurate refraction critical in most cases
More informationSoft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs
Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals
More informationKeratoconus contact lenses
Indic ations All Keratoconus. Daily wear. Recommended replacement: < 2 years. Design Aberration control aspheric optics providing outstanding acuity, reduced flare and glare. Unique design that changes
More informationTrouble Shooting Guide for Ortho-K lenses
Trouble Shooting Guide for Ortho-K lenses The basic design of the third generation e Lens for Orthokeratology 1. Optic Zone (Base curve, Compression zone, BC) width 5.6 to 6.4mm 2. Fitting curve (second
More informationIrregular Corneas. Expanding Your Lens Options for SPECTRUM. Experts discuss a customized soft lens that delivers visual acuity and comfort.
Contact Lens SPECTRUM NOVEMBER 2013 Expanding Your Lens Options for Irregular Corneas Experts discuss a customized soft lens that delivers visual acuity and comfort. Sponsored by Custom Lab Channel Business
More informationClearKone Restoring vision. Changing lives.
ClearKone Restoring vision. Changing lives. For additional information on fitting ClearKone, please visit www.fitsynergeyes.com to view fitting videos, case studies, NaFL pictures and more. FITTING GUIDE
More informationFITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS
THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS FITTING GUIDE Applications Design Options NORMAL PROLATE CORNEAS PRESBYOPIA ASTIGMATISM EMERGENT OR FRUSTE KERATOCONUS
More informationFOR FREQUENT REPLACEMENT SOFT HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE
AVAIRA (enfilcon A) AVAIRA Toric (enfilcon A) & AVAIRA Multifocal (enfilcon A) FOR FREQUENT REPLACEMENT SOFT HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE Part Number: PFG01012 Page 1 of 13 Table
More informationOptical Connection, Inc. and Ophthonix, Inc.
Optical Connection, Inc. and Ophthonix, Inc. Partners in the delivery of nonsurgical vision optimization www.opticonnection.com www.ophthonix.com The human eye has optical imperfections that can not be
More informationA Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia
13 A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia Ann M. Foss Faculty Sponsor: Margaret A. Maher, Departments of Biology/Microbiology Clinical Sponsor: Richard L. Foss, O.D. ABSTRACT
More informationSlide 1. Slide 2. Slide 3. Richard Dorer NCLE
Slide 1 Heart of America 2014 Richard Dorer NCLE richarddorer@gmail.com Slide 2 I am a paid representative and consultant of Blanchard Contact Lens. I represent Blanchard Contact Lens in the Mid-Western
More informationSubmission to the American Optometric Association Contact Lens and. Cornea Section, Student Research Awards Committee. for
Submission to the American Optometric Association Contact Lens and Cornea Section, Student Research Awards Committee for My Most Challenging Contact Lens Case By: Melisa Hockett Third year Doctor of Optometry
More information10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?
Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens
More informationATLAS Corneal Topography System
ATLAS Corneal Topography System Simply accurate for maximum productivity Model 9000 The New ATLAS Take your practice to the next level Carl Zeiss Meditec has taken the world s leading corneal topography
More informationPROFESSIONAL FITTING GUIDE
PROFESSIONAL FITTING GUIDE FluoroPerm 92 (paflufocon A) Rigid Gas Permeable Contact Lenses for Daily Wear with Tangible TM Hydra-PEG FluoroPerm 60 (paflufocon B) Rigid Gas Permeable Contact Lenses for
More informationThe Aberration Structure of the Keratoconic Eye
The Aberration Structure of the Keratoconic Eye Geunyoung Yoon, Ph.D. Department of Ophthalmology Center for Visual Science Institute of Optics Department of Biomedical Engineering University of Rochester
More information(495) (495)
МЕДТЕХНИКА-СТОЛИЦА (495) 902-59-26 (495) 518-55-99 127 238, г. Москва, Дмитровское ш. 85 ATLAS Corneal Topography Product Overview Model 9000 ATLAS Model 9000 Overview Next-generation corneal topography
More informationHistory of SCL. What is with all these Soft Contacts!? Krystle Kennedy, O.D. In 1999, PureVision, the world s first silicone hydrogel is introduced
History of SCL What is with all these Soft Contacts!? Publication about SCL first appeared in 1960s, by Czech doctors. Best VA 20/40 Krystle Kennedy, O.D. In March 1971, B&L had the entire soft lens system
More informationPROFESSIONAL FITTING AND INFORMATION GUIDE
CAUTION: PROFESSIONALFITTINGAND INFORMATIONGUIDE FLOSI(wilofoconA) RigidGasPermeableContactLensesforDailyWear ONSI 56(onsifoconA) RigidGasPermeableContactLensesforDailyWear TYRO 97(hofoconA) RigidGasPermeableContactLensesforDailyWear
More informationPREMIUM LENSES WITH VARIABLE BASE CURVE
PREMIUM LENSES WITH VARIABLE BASE CURVE Inspired by nature - 1 - CONTENT THE ADVANCEMENT OF CAMBER CAMBER TECHNOLOGY Features and Properties Camber Benefits EXPLORING CAMBER LENS SERIES NATURAL NATURAL
More informationFITTING GUIDE. Applications. Design Options OPTIMUM OXYGENATION FOR LONG-TERM CORNEAL HEALTH
OPTIMUM OXYGENATION FOR LONG-TERM CORNEAL HEALTH FITTING GUIDE Applications Design Options NORMAL PROLATE CORNEAS PRESBYOPIA ASTIGMATISM EMERGENT OR FRUSTE KERATOCONUS SOFT CONTACT LENS INTOLERANT SMALL
More informationUsing Orthotool Software
Using Orthotool Software OrthoTool 101010 (2008) Original Design with 5 Curves. You can just use the new version 2013 Toric RC, AC & PC only with OT 2008 so far Hyperopic ortho-k GP lens design Aspheric
More informationCooper Vision. Clariti 1 day Multifocals
Hello. Welcome to part two of Pacific University s Online Web CE on fitting multifocal soft contact lenses. My name is Michelle Darnell, and I am an optometrist at a private practice in Spokane, Washington.
More informationADVANCED CLINICAL APPLICATIONS AND TROUBLESHOOTING IN SCLERAL LENSES
ADVANCED CLINICAL APPLICATIONS AND TROUBLESHOOTING IN SCLERAL LENSES Langis Michaud, OD Jason Jedlicka, OD Disclosures Langis Honorarium and research grants Alcon Cooper Allergan Bausch*Lomb Johnson *
More informationBetter Optics Deliver Clear, Consistent Vision
Better Optics Deliver Clear, Consistent Vision Learn how the PureVision2 family can satisfy patients and help build your practice. By Agustin Gonzalez, OD Learning What Patients Want The NSIGHT study provides
More informationOPH 260 BASIC CONTACT LENS CONCEPTS
OPH 260 BASIC CONTACT LENS CONCEPTS COURSE DESCRIPTION: Prerequisites: OPH 121 and OPH 141 Corequisites: None This course introduces the theory of contact lens fitting. Emphasis is on rigid and soft contact
More informationThe Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l
C2 MULTIFOCAL The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l C o n t a c t L e n s UNIQUE DESIGN E X C E L L E N T V I S I O N F O R A L L P R E S B Y O P E S VISUAL EXCELLENCE IN SIMULTANEOUS
More informationCET CONTINUING. Dealing with complex prescriptions & surgical cases. What Are The Options?
4 Approved for Optometrists Approved for DOs Approved for CLPs 28 Contact lens part 4 Dealing with complex prescriptions & surgical cases Course code: C-13550 O/D/CL Sophie Taylor-West BSc (Hons) MCOptom
More informationaoa.org/spv Sponsored by a grant from
Sponsored by a grant from Define vision relative to common paradigm Identify and discuss appropriate options for refractive error of the athlete Understand when contact lenses are preferred vs. spectacles
More informationMehrstärken- Kontaktlinsen Michael Wyss
Mehrstärken- Kontaktlinsen Michael Wyss dipl. Augenoptiker FAAO mwyss@kontaktlinsenstudio.ch kontaktlinsenstudio baertschi, Bern, Switzerland Situation on the market Blind-Date Get in contact with your
More informationRefractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens
Refractive Surgery: My Way Vance Thompson, MD, FACS Refractive Surgeon Vance Thompson Vision Sioux Falls, SD Disclosures Abbott Medical Optics Alcon Avedro Calhoun Euclid Systems EyeBrain Medical Forsight
More informationWhat is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?
Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Ian Cox, BOptom, PhD, FAAO Distinguished Research Fellow Bausch & Lomb, Rochester, NY Acknowledgements Center for Visual
More informationCorrection of Presbyopia. with GP Contact Lenses
Correction of Presbyopia with GP Contact Lenses Acknowledgements Development of the Correction of Presbyopia with GP Contact Lenses booklet was supported through an educational grant from Polymer Technology,
More informationPre-Fitting - History
Pre-Fitting History taking External exam Prescriptions Keratometry/Topography Lens Selection Soft and RGP Insert and Removal (I&R) Tools Stacy Campbell NCLE-AC, COA Eye Care Associates scampbell@eyecare1.com
More informationOptometry s Meeting. Tom Quinn s Disclosures. Shalu Pal s Disclosures. Multifocal Contact Lenses Made Simple 5/18/2015
Optometry s Meeting Multifocal Contact Lenses Made Simple Shalu Pal, O.D., F.A.A.O. Tom Quinn, O.D., M.S., F.A.A.O. Tom Quinn s Disclosures Alcon Allergan Alden Optical Bausch + Lomb CooperVision GPLI
More informationProfessional Fitting and Information Guide
Professional Fitting and Information Guide FOCUS DAILIES FOCUS DAILIES Toric FOCUS DAILIES Progressives DAILIES AquaComfort Plus DAILIES AquaComfort Plus Toric DAILIES AquaComfort Plus Multifocal (nelfilcon
More informationAdvanced Fitting of Scleral Lenses
Advanced Scleral Lens Fitting Advanced Fitting of Scleral Lenses Jason Jedlicka, OD, FAAO Indiana University Evalua?ng fit at follow up Evalua?ng landing zone Dealing with as?gma?sm in the over refrac?on
More informationHeads you win, tails you lose
4 dispensingoptics September 2014 Heads you win, tails you lose By Andrew Keirl BOptom (Hons) MCOptom FBDO CompetencIes covered: Dispensing opticians: Ocular Examination, Contact Lenses, efractive Management
More informationFITTING & PATIENT MANAGEMENT GUIDE
FITTING & PATIENT MANAGEMENT GUIDE 1-DAY ACUVUE Brand (etafilcon A) Soft (hydrophilic) Contact Lenses Visibility Tinted with UV Blocker for Daily Disposable Wear CAUTION: U.S. Federal law restricts this
More informationIMPORTANT: Please read carefully and keep this information for future use.
IMPORTANT: Please read carefully and keep this information for future use. This fitting guide is intended for the eye care practitioner, but should be made available to the patient upon request. The eye
More informationOCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance
OCULUS Easygraph So Small and Yet a Topographer Small, but Efficient As a Big One Wanting to work with a video keratometer in spite of limited space? Then the OCULUS Easygraph is what you re looking for.
More informationChoices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12
Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays
More informationOCULUS Easygraph. Topographer. We focus on progress
OCULUS Easygraph Topographer We focus on progress The Compact Corneal Topographer at a Glance Corneal topographer with built-in keratometer Comfortable, hygienic working distance reduces the influence
More informationNOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.
NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The
More informationWave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer
Wave Front Topography ReSeeVit Evolution Topography Module for Modi Topographer Introduction The aberrations in the central optical zone have a greater effect than those closer to the edge. From an optical
More informationAdvanced Fitting Guide
Advanced Fitting Guide Keratoconus Pellucid Marginal Corneal Degeneration Corneal Ectasia Corneal Graft Irregular Cornea Post Refractive Surgery Astigmatism Chronic Dry Eye Sports 1 Innovators of Software,
More informationClinical Update for Presbyopic Lens Options
Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration
More informationPACKAGE INSERT. Paraperm EW (pasifocon C) Rigid Gas Permeable Contact Lenses for Daily and Extended Wear
PACKAGE INSERT Paraperm EW (pasifocon C) Rigid Gas Permeable Contact Lenses for Daily and Extended Wear Paraperm O 2 (pasifocon A) Rigid Gas Permeable Contact Lenses for Daily Wear Shipped Dry IMPORTANT
More informationFOR PRECISE ASTIGMATISM CORRECTION.
WHY TORIC INTRAOCULAR LENSES? FOR PRECISE ASTIGMATISM CORRECTION. PATIENT INFORMATION Cataract treatment OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR CONCERNS WE CAN HELP. Dear patient, Discovering
More informationWhat s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina
What s Fundus photography s purpose? To document the retina Photographers role to show the retina Document other ocular structures Why do we take them? Why do we do it? We as photographers help the MD
More informationKeratoconus is one of the most leading causes for visual disability
ARTICLE A New Fitting Approach for Providing Adequate Comfort and Visual Performance in Keratoconus: Soft HydroCone (Toris K) Lenses Koray Gumus, M.D., FEBOphth. and Nisa Kahraman, M.D. Objective: To evaluate
More information2008 Hoya Grant & Scholarship Wining Case Study
2008 Hoya Grant & Scholarship Wining Case Study Progressive Lens Technology and the Implications for Struggling Presbyopes with Peripheral Distortion and Blur: A Case Study Andrew M. Graves 3 rd Year Optometry
More informationMelissa Barnett, OD, FAAO, FSLS, FBCLA
??????? Melissa Barnett, OD, FAAO, FSLS, FBCLA?? Melissa Barnett has received honoraria from: Acculens Alcon Allergan Bausch + Lomb Coopervision JJVC Vistakon Novabay Gas Permeable Lens Institute (GPLI)
More informationCrystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN
Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics
More informationContact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia
Contact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia Andrew J Toole, OD, PhD, FAAO The Ohio State University College of Optometry Disclosure Statement: Nothing to disclose Aniseikonia
More informationWhat s New in Ocular Biomechanics?
What s New in Ocular Biomechanics? The International Congress of Wavefront Sensing & Optimized Refractive Corrections Wavefront Course January 28, 2006 Torrence A. Makley Research Professor Department
More informationLASIK & Refractive Surgery
LASIK & Refractive Surgery LASIK PRK ICL RLE Monovision + + + Understanding the Basics: Why You Need Vision Correction What is a refraction and refractive error? First and foremost, we should give you
More informationEmpirical fitting of soft or rigid gas-permeable contact lenses for the correction of moderate to severe refractive astigmatism: A comparative study
Optometry (2009) 80, 375-383 Empirical fitting of soft or rigid gas-permeable contact lenses for the correction of moderate to severe refractive astigmatism: A comparative study Langis Michaud, O.D., a
More informationRefractive Power / Corneal Analyzer. OPD-Scan III
Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer
More informationCustomized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens
Journal of the Korean Physical Society, Vol. 49, No. 1, July 2006, pp. 121 125 Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens
More informationSpherical VS Aspheric. BC Flatten Faster creating extra force at RZ
Spherical VS Aspheric BC Flatten Faster creating extra force at RZ Aspheric BOZ As Function Of Treatment Zone (Back Optical Zone) BC Radius Flatten Faster Towards Edge Of BOZ OZD=5.2 mm OZD=6.0 mm Fitting/Reverse
More informationHARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS
Mario Giovanzana Milano 20.06.01 HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS An astigmatism, according to Whevell (1817) has been defined as astigmatism or astigmatic ametropia; the
More informationChoices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12
Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,
More informationPatient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs
Patient information Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs Bring your vision into focus Good vision is a major contributor to the quality of life.
More informationVARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES
VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES WELCOME We are pleased to present this guide which outlines the essential steps for successfully fitting progressive lenses to your
More information3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s
IAO/COS March 7, 2014 Peter Russo, OD, FAAO Professor Department of Ophthalmology Loyola University Medical Center Edward Hines Jr. VAMC No financial disclosures. We don t; we just look better in CL s.
More informationImproving Lifestyle Vision. with Small Aperture Optics
Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining
More informationNormalEyes Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES. Manufactured in Paragon HDS 1OO (paflufocon D)
NormalEyes 15.5 Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES Manufactured in Paragon HDS 1OO (paflufocon D) FOR DAILY WEAR PARAGON VISION SCIENCES Just watch us 2012 Paragon
More informationMultiple-Choice Questions
Multiple-Choice Questions A Board Review Manual 1. A +5.ooD hyperope, with a PD (inter-pupillary distance) of 5 centimeters, is mistakenly given glasses which are decentered outward by 5mm OU. The total
More informationA CA system for RGP contact lens design
International conference on Innovative Methods in Product Design June 15 th 17 th, 2011, Venice, Italy A CA system for RGP contact lens design L. D Angelo (a), M. Rizzi (a) (a) University of Ferrara, Engineering
More informationNEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL
NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY
More informationVision Shaping Treatment
JOHN WARREN, OD Vision Shaping Treatment WWW.WARRENEYECARECENTER.COM What Is VST? Using customized vision retainer lenses, VST reshapes the front surface of the eye, reducing nearsightedness and astigmatism
More informationSumit Malhotra Praveen Vashist Noopur Gupta Suraj Singh Senjam Sanjeev Kumar Gupta
Sumit Malhotra Praveen Vashist Noopur Gupta Suraj Singh Senjam Sanjeev Kumar Gupta Department of Community Ophthalmology Dr. Rajendra Prasad Centre for Ophthalmic Sciences and Centre for Community Medicine
More informationTreatment of Presbyopia during Crystalline Lens Surgery A Review
Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements
More informationGP LENS UPDATE ADVANCEMENT ONE: AFFILIATIONS GP LENSES IN /20/2014. THE FUTURE OF GPs (Yes: the Future is Bright!) GP Update: Oct.
GP LENS UPDATE Ed Bennett OD, MSEd, FAAO ADVANCEMENT ONE: SCLERAL LENSES AFFILIATIONS Contact Lens Manufacturers Association: Consultant and Executive Director, GP Lens Institute THE FUTURE OF GPs (Yes:
More information