Macro Varon 4.5/85. Key features. Applications. Web and surface inspections
|
|
- Godwin Conley
- 5 years ago
- Views:
Transcription
1 The Macro Varon lens has been designed for high resolution 12k line scan cameras with 3.5 µm pixel pitch. They are optimized for an optical magnification range of.5x to 2.x. CAS-lens technology produces uniform high performance over the entire magnification range. A special design ensures a constant focal length at any magnification. Complete elimination of inherent vignetting effects yields to homogeneous intensity over the entire field. The Macro Varon lens is designed for industrial machine vision applications and improves the overall system performance of high resolution inspection processes. A lockable iris adjustment mechanism ensures system stability, even in the presence of vibration. This lens is efficient for many web and other surface inspection applications as FPD and PCB inspection. A 3.5x magnification version with beam splitter is also available. Key features For 12k line scan sensors with 3.5 μm pixel sizes Magnification range using a single lens from.5x to 2.x CAS Continuous Aberration Suppression Maintains diffraction-limited performance over the entire magnification range Low distortion Applications Web and surface inspections FPD inspection PCB inspection OLED inspection Line scan applications 4 nm to 1 nm broadband AR coating V-Mount connection Name Name Type -18 Focal Length [mm] 85 Magnification -1 Image circle [mm] 62 Resolution [µm] 5 F/# range NA.11 Weight [g] 27 Storage temperature [ C] f eff [mm] S F [mm] S F [mm] HH [mm] β P 1.8 Interface V38-Mount S EP [mm] 22.2 Working distance [mm] 13 AoV [ ] 4 S AP [mm] Σd [mm] Focus control manual ID Transmission [nm] 4-1 Filter thread [mm] M37 x.75 Dimensions L x D [mm] 48. x 48.5 We accept no responsibility for any errors and reserve the right of modification without further notice. 1 / 5
2 Distortion vs. Image Height Distortion / % Distortion vs. Field Hei ' = -2. ' = -1. ' = -.5 Transmittance vs. Wavelength Transmittance / % Wavelength / nm Relative Illumination vs. Image Height Rel. Illumination vs. Field Position 1 Rel. Illumination / % F# = 4.5, ' = -2. F# = 5.6, ' = -2. F# = 8., ' = -2. F# = 4.5, ' = -1. F# = 5.6, ' = -1. F# = 8., ' = -1. F# = 4.5, ' = -.5 F# = 5.6, ' = -.5 F# = 8., ' = -.5 We accept no responsibility for any errors and reserve the right of modification without further notice. 2 / 5
3 Spectrum Name VIS Wavelenghts [nm] Weights F# = 4.5, ' = -2., OO' = 378 F# = 5.6, ' = -2., OO' = 378 F# = 8., ' = -2., OO' = F# = 4.5, ' = -1., OO' = 336 F# = 5.6, ' = -1., OO' = 336 F# = 8., ' = -1., OO' = F# = 4.5, ' = -.5, OO' = 378 F# = 5.6, ' = -.5, OO' = 378 F# = 8., ' = -.5, OO' = lp/mm, tangential 2. lp/mm, radial 4. lp/mm, tangential 4. lp/mm, radial 8. lp/mm, tangential 8. lp/mm, radial We accept no responsibility for any errors and reserve the right of modification without further notice. 3 / 5
4 Accessories Mount Length ID Macro UNIFOC 12 V38 / V UNIFOC 7 V38 / V UNIFOC 7 V38 / M58 x Ext. Tube T2 / T2 6 mm M58 x.75 8 mm 1351 M58 x.75 1 mm 135 M72 x mm M72 x.75 5 mm M72 x mm 2646 Adapter V38 / C-Mount V38 / C-Mount Hub mm V38 / Leica (M39 x 26 Gg.) V38 / T2 (M42 x.75) V38 / M42 x V38 / M42 x 1 35 mm V38 / M58 x V38 / Nikon F-Mount We accept no responsibility for any errors and reserve the right of modification without further notice. 4 / 5
5 Get more information Contact our local offices Headquarter Germany Jos. Schneider Optische Werke GmbH Ringstraße Bad Kreuznach S cs@schneiderkreuznach.com Offices Worldwide China S shawn.liu@schneider-asiapacific.com North America S (East Coast) S (West Coast) info@schneideroptics.com Singapore S thongv@schneiderkreuznach.com We accept no responsibility for any errors and reserve the right of modification without further notice. 5 / 5
Xenon-Zirconia 3.3/92
This lens with.2x magnification is optimized for the use with 12k (62.5 mm) line scan sensors with 5 µm pixel, but can also be used with 16k (82 mm) lines. It is broadband coated and can be used in the
More informationXenon-Diamond 2.9/106 With beam splitter
Xenon-Diamond 2.9/16 This high resolution 2.6x line scan lens with beam splitter is optimized for the use with 12k (62.5 mm) line scan sensors with 5 µm pixel, but can also be used with 16k / 5 µm (82
More informationTECHSPEC COMPACT FIXED FOCAL LENGTH LENS
Designed for use in machine vision applications, our TECHSPEC Compact Fixed Focal Length Lenses are ideal for use in factory automation, inspection or qualification. These machine vision lenses have been
More informationThe Importance of Wavelengths on Optical Designs
1 The Importance of Wavelengths on Optical Designs Bad Kreuznach, Oct. 2017 2 Introduction A lens typically needs to be corrected for many different parameters as e.g. distortion, astigmatism, spherical
More informationBasler Accessories. Technical Specification BASLER LENS C M. Order Number
Basler Accessories Technical Specification BASLER LENS C23-526-2M Order Number 22183 Document Number: DG1916 Version: 1 Language: (English) Release Date: 17 January 218 Contacting Basler Support Worldwide
More informationBasler Accessories. Technical Specification BASLER LENS C M. Order Number
Basler Accessories Technical Specification BASLER LENS C23-1616-2M Order Number 2200000180 Document Number: DG001913 Version: 01 Language: 000 (English) Release Date: 17 January 2018 Contacting Basler
More informationOptical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH
Optical basics for machine vision systems Lars Fermum Chief instructor STEMMER IMAGING GmbH www.stemmer-imaging.de AN INTERNATIONAL CONCEPT STEMMER IMAGING customers in UK Germany France Switzerland Sweden
More informationFor high resolution, large-sized line sensor cameras. Recommendable line sensor cameras - 5.2μm x 12K / 7μm x 8K
Nikon Rayfact Series Features For high resolution, large-sized line sensor cameras. Recommendable line sensor cameras - 5.2μm x 12K / 7μm x 8K Guarantee high resolution and uniformity from the center to
More informationOptical and mechanical parameters. 100 mm N. of elements 20.5 mm Dimensions 11.7 degrees Weight F/N = 4 (fixed) N.A.
OB SWIR 100 LENS OB-SWIR100/4 P/N C0416 General Description This family of high resolution SWIR lenses image from 0.9 2.3 µmm making them especially well-suited for PCB inspection, special laser applications,
More informationLENS ZOOM-SWIR 7x P/N C0628
ZOOM SWIR 7x LENS ZOOM-SWIR 7x P/N C0628 General Description This family of high resolution SWIR lenses image from 0.9 2.3 m making them especially well-suited for PCB inspection, special laser applications,
More informationTelecentric lenses.
Telecentric lenses 2014 Bi-Telecentric lenses Titolo Index Descrizione Telecentric lenses Opto Engineering Telecentric lenses represent our core business: these products benefit from a decade-long effort
More informationNikon Rayfact VF. Features. Applications. ver2.2
Nikon Rayfact VF Features Variable magnification range : 0.5x - 3.0x Image size φ 64mm to meet large-sized high resolution line censor cameras. Suitable for line censor cameras of 7μm x 8K / 5μm x 12K.
More informationLENS OB-SWIR500/7 P/N C0615
LENS OB-SWIR500/7 P/N C0615 General Description This family of high resolution SWIR lenses image from 0.9 2.3 m making them especially well-suited for PCB inspection, special laser applications, surveillance
More informationVariable microinspection system. system125
Variable microinspection system system125 Variable micro-inspection system Characteristics Large fields, high NA The variable microinspection system mag.x system125 stands out from conventional LD inspection
More information7x P/N C1601. General Description
METRICZOOM SWIR 7x METRIC ZOOM-SWIR ZOOM 7x P/N C1601 C General Description This family of high resolution METRIC ZOOM SWIR lenses image from 0.9 to 2.3 µm making them especially well-suited well for surveillance,
More informationUsing Optics to Optimize Your Machine Vision Application
Expert Guide Using Optics to Optimize Your Machine Vision Application Introduction The lens is responsible for creating sufficient image quality to enable the vision system to extract the desired information
More informationSpeed and Image Brightness uniformity of telecentric lenses
Specialist Article Published by: elektronikpraxis.de Issue: 11 / 2013 Speed and Image Brightness uniformity of telecentric lenses Author: Dr.-Ing. Claudia Brückner, Optics Developer, Vision & Control GmbH
More informationNikon Rayfact Series. Features. Applications. ver2.2
Nikon Rayfact Series Features Rayfact 2x and 1x : successor models to Printing Nikkor Lenses. No lens aberration (0.0%) at the standard magnification ratio. Guarantee high resolution and uniformity from
More informationMML-High Resolution 5M Series
Fixed Magnification Series -High Resolution 5M Series High-resolution models that possess the best contrast and NA of all Series. Image acquisition with even higher image quality is realized by combining
More informationINFLUENCE OF VARIABLE APERTURE STOP
INFLUENCE OF VARIABLE APERTURE STOP IN TELECENTRIC IMAGING LENSES SILL OPTICS GMBH CO. KG TECHNOLOGY FORUM MACHINE VISION 2015/16 Konrad Hentschel, Dipl-Phys. Andreas Platz, M.Sc. Project Management CONTENT
More informationAdvanced Optics for Vision. Stuart W. Singer Sr. Vice President & CTO Schneider Optics, Inc.
Advanced Optics for Vision Stuart W. Singer Sr. Vice President & CTO Schneider Optics, Inc. Table of Contents Modulation Transfer Function (MTF) What does it mean Aberration effects f/number effects Manufacturing
More informationOptical design of a high resolution vision lens
Optical design of a high resolution vision lens Paul Claassen, optical designer, paul.claassen@sioux.eu Marnix Tas, optical specialist, marnix.tas@sioux.eu Prof L.Beckmann, l.beckmann@hccnet.nl Summary:
More informationWhere Image Quality Begins
Where Image Quality Begins Filters are a Necessity Not an Accessory Inexpensive Insurance Policy for the System The most cost effective way to improve repeatability and stability in any machine vision
More informationLEICA Summarit-S 70 mm ASPH. f/2.5 / CS
Technical Data. Illustration 1:2 Technical Data Order no. 1155 (CS: 1151) Image angle (diagonal, horizontal, vertical) approx. 42 / 35 / 24, corresponds to approx. 56 focal length in 35 format Optical
More informationDatasheet. ELIIXA+ 16k/8k CP Cmos Multi-Line Color Camera. Features. Description. Application. Contact us online at: e2v.
Datasheet ELIIXA+ 16k/8k CP Cmos Multi-Line Color Camera Features Cmos Colour Sensor : - 16384 RGB Pixels, 5 x 5µm (Full Definition) - 8192 RGB Pixels 10x10µm (True Colour) Interface : CoaXPress (4x 6Gb/sLinks)
More informationImaging Optics Fundamentals
Imaging Optics Fundamentals Gregory Hollows Director, Machine Vision Solutions Edmund Optics Why Are We Here? Topics for Discussion Fundamental Parameters of your system Field of View Working Distance
More informationNikon Rayfact IL Series
Nikon Rayfact IL Series Features Compatible with EL Nikkor40mmF4N, 50mmF2.8N, 63mmF2.8N and 75mmF4N Lineup : 4 models New product release : NikonRayfactIL95mmF5.6N * 4 models cover a wide range of magnification
More informationLEICA VARIO-ELMARIT-R mm f/2,8-4,5 ASPH. 1
LEICA VARIO-ELMARIT-R -9 mm f/,-4, ASPH. The LEICA VARIO-ELMARIT-R -9mm f/.-4. ASPH. is a truly universal lens, which covers a broad range of focal lengths but still proves very fast. It is a lens which,
More informationPerformance data of a new 248 nm CD metrology tool proved on COG reticles and PSM s
Performance data of a new 248 nm CD metrology tool proved on COG reticles and PSM s Gerhard Schlueter a, Walter Steinberg a, John Whittey b a Leica Microsystems Wetzlar GmbH Ernst-Leitz-Str. 17-37, D-35578
More informationIMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2
KODAK for use with the KODAK CMOS Image Sensors November 2004 Revision 2 1.1 Introduction Choosing the right lens is a critical aspect of designing an imaging system. Typically the trade off between image
More informationmm F2.6 6MP IR-Corrected. Sensor size
1 1 inch and 1/1.2 inch image size spec. Sensor size 1-inch 1/1.2-inch 2/3-inch Image circle OK OK OK OK 1/1.8-inch OK 1/2-inch OK 1/2.5-inch 1 1-inch CMV4000 PYTHON5000 KAI-02150 KAI-2020 KAI-2093 KAI-4050
More informationImage Formation and Capture. Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen
Image Formation and Capture Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen Image Formation and Capture Real world Optics Sensor Devices Sources of Error
More informationOptical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember
Günter Toesko - Laserseminar BLZ im Dezember 2009 1 Aberrations An optical aberration is a distortion in the image formed by an optical system compared to the original. It can arise for a number of reasons
More informationattocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G
APPLICATION NOTE M01 attocfm I for Surface Quality Inspection Confocal microscopes work by scanning a tiny light spot on a sample and by measuring the scattered light in the illuminated volume. First,
More informationChoosing the Best Optical Filter for Your Application. Georgy Das Midwest Optical Systems, Inc.
Choosing the Best Optical Filter for Your Application Georgy Das Midwest Optical Systems, Inc. Filters are a Necessity, Not an Accessory. Key Terms Transmission (%) 100 90 80 70 60 50 40 30 20 10 OUT-OF-BAND
More informationA 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei
Key Engineering Materials Online: 005-10-15 ISSN: 166-9795, Vols. 95-96, pp 501-506 doi:10.408/www.scientific.net/kem.95-96.501 005 Trans Tech Publications, Switzerland A 3D Profile Parallel Detecting
More informationOptical design of camera optics for mobile phones
Adv. Opt. echn., Vol. 1 (2012), pp. 51 58 Copyright 2012 HOSS Media and De Gruyter. DOI 10.1515/aot-2012-0002 esearch Article Optical design of camera optics for mobile phones homas Steinich and Vladan
More informationCriteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design
Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design Computer Aided Design Several CAD tools use Ray Tracing (see
More informationImproved Spectra with a Schmidt-Czerny-Turner Spectrograph
Improved Spectra with a Schmidt-Czerny-Turner Spectrograph Abstract For years spectra have been measured using traditional Czerny-Turner (CT) design dispersive spectrographs. Optical aberrations inherent
More informationLecture Notes 10 Image Sensor Optics. Imaging optics. Pixel optics. Microlens
Lecture Notes 10 Image Sensor Optics Imaging optics Space-invariant model Space-varying model Pixel optics Transmission Vignetting Microlens EE 392B: Image Sensor Optics 10-1 Image Sensor Optics Microlens
More informationZ-LASER Optoelektronik GmbH Stemmer 3d Technologietag Useful information on Z-Lasers for Vision
Z-LASER Optoelektronik GmbH Stemmer 3d Technologietag - 24.2.2011 Useful information on Z-Lasers for Vision The Company Core Competences How to Build a Z-LASER Electronics and Modulation Wavelength and
More informationdon, G.B. U.S. P. DOCUMENTS spaced by an air gap from the collecting lens. The widths of
United States Patent (19) Wartmann III US005708532A 11 Patent Number: 5,708,532 45 Date of Patent: Jan. 13, 1998 (54) DOUBLE-SIDED TELECENTRC 573790 11/1977 U.S.S.R... 359/663 MEASUREMENT OBJECTIVE 1 248
More informationECEN 4606, UNDERGRADUATE OPTICS LAB
ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant
More informationApplication Note (A11)
Application Note (A11) Slit and Aperture Selection in Spectroradiometry REVISION: C August 2013 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com
More informationSuper High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series
Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series Nikon's proprietary scanning-type optical interference measurement technology achieves 1pm* height resolution. * Height
More informationABOUT RESOLUTION. pco.knowledge base
The resolution of an image sensor describes the total number of pixel which can be used to detect an image. From the standpoint of the image sensor it is sufficient to count the number and describe it
More informationLENSES. INEL 6088 Computer Vision
LENSES INEL 6088 Computer Vision Digital camera A digital camera replaces film with a sensor array Each cell in the array is a Charge Coupled Device light-sensitive diode that converts photons to electrons
More informationOptics: An Introduction
It is easy to overlook the contribution that optics make to a system; beyond basic lens parameters such as focal distance, the details can seem confusing. This Tech Tip presents a basic guide to optics
More informationSupermacro Photography and Illuminance
Supermacro Photography and Illuminance Les Wilk/ReefNet April, 2009 There are three basic tools for capturing greater than life-size images with a 1:1 macro lens --- extension tubes, teleconverters, and
More informationEE-527: MicroFabrication
EE-57: MicroFabrication Exposure and Imaging Photons white light Hg arc lamp filtered Hg arc lamp excimer laser x-rays from synchrotron Electrons Ions Exposure Sources focused electron beam direct write
More informationCalibration Report. Short Version. Vexcel Imaging GmbH, A-8010 Graz, Austria
Calibration Report Short Version Camera: Manufacturer: UltraCam D, S/N UCD-SU-2-0039 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Mar-14-2011 Date of Report: Mar-17-2011 Camera Revision:
More informationBROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL. HEADLINE: HDTV Lens Design: Management of Light Transmission
BROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL HEADLINE: HDTV Lens Design: Management of Light Transmission By Larry Thorpe and Gordon Tubbs Broadcast engineers have a comfortable familiarity with electronic
More informationThe future of the broadloom inspection
Contact image sensors realize efficient and economic on-line analysis The future of the broadloom inspection In the printing industry the demands regarding the product quality are constantly increasing.
More informationIntegre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.
Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Multi-color scanning photocoagulation takes on a new look. Integre Pro Scan
More informationAdvanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera
Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera Figure 1. The Zeta-20 uses the Grasshopper3 and produces true color 3D optical images with multi mode optics technology 3D optical profiling
More informationDifferences Between the A101f/fc and the A102f/fc
Differences Between the A101f/fc and the A102f/fc Version 1.1, October 13, 2003 Introduction Basler is introducing a new megapixel camera family at the Vision Show 2003 (October 21-23). As you know, the
More informationOpti 415/515. Introduction to Optical Systems. Copyright 2009, William P. Kuhn
Opti 415/515 Introduction to Optical Systems 1 Optical Systems Manipulate light to form an image on a detector. Point source microscope Hubble telescope (NASA) 2 Fundamental System Requirements Application
More informationCALIBRATION REPORT SUMMARY
CALIBRATION REPORT SUMMARY Material Description Assembly 2PADI080 1027 0997 A / 09A Camera Module 1 CCD KODAK KAF 39Mp Full Frame Color Image Sensor SN CQ011027 Lens Schneider Apo Digitar 4.0/80 N SN 15006871
More informationPoint Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy
Bi177 Lecture 5 Adding the Third Dimension Wide-field Imaging Point Spread Function Deconvolution Confocal Laser Scanning Microscopy Confocal Aperture Optical aberrations Alternative Scanning Microscopy
More informationSIL for improved sensitivity and spatial resolution
SIL for improved sensitivity and spatial resolution Herve Deslandes, DCG Systems EUFANET - Jan 26 2009 Why is Sensitivity important? High resolution fault localization requires enough sensitivity at high
More informationCamera Selection Criteria. Richard Crisp May 25, 2011
Camera Selection Criteria Richard Crisp rdcrisp@earthlink.net www.narrowbandimaging.com May 25, 2011 Size size considerations Key issues are matching the pixel size to the expected spot size from the optical
More informationSpatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source
Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source Shlomi Epshtein, 1 Alon Harris, 2 Igor Yaacobovitz, 1 Garrett Locketz, 3 Yitzhak Yitzhaky, 4 Yoel Arieli, 5* 1AdOM
More informationNikon 24mm f/2.8d AF Nikkor (Tested)
Nikon 24mm f/2.8d AF Nikkor (Tested) Name Nikon 24mm ƒ/2.8d AF Nikkor Image Circle 35mm Type Wide Prime Focal Length 24mm APS Equivalent 36mm Max Aperture ƒ/2.8 Min Aperture ƒ/22 Diaphragm Blades 7 Lens
More informationVC 11/12 T2 Image Formation
VC 11/12 T2 Image Formation Mestrado em Ciência de Computadores Mestrado Integrado em Engenharia de Redes e Sistemas Informáticos Miguel Tavares Coimbra Outline Computer Vision? The Human Visual System
More informationExam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.
Name: Class: Date: Exam 4 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Mirages are a result of which physical phenomena a. interference c. reflection
More informationAn Indian Journal FULL PAPER. Trade Science Inc. Parameters design of optical system in transmitive star simulator ABSTRACT KEYWORDS
[Type text] [Type text] [Type text] ISSN : 0974-7435 Volume 10 Issue 23 BioTechnology 2014 An Indian Journal FULL PAPER BTAIJ, 10(23), 2014 [14257-14264] Parameters design of optical system in transmitive
More informationSome of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)
Lens design Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Focal length (f) Field angle or field size F/number
More informationPress Release. New packaging design for B+W filters. BAD KREUZNACH, 20 September Stylish appearance and clear orientation for the customer
Press Release BAD KREUZNACH, 20 September 2018 New packaging design for B+W filters Stylish appearance and clear orientation for the customer Informative and high-quality at the same time: Both retailers
More informationHow to Choose a Machine Vision Camera for Your Application.
Vision Systems Design Webinar 9 September 2015 How to Choose a Machine Vision Camera for Your Application. Andrew Bodkin Bodkin Design & Engineering, LLC Newton, MA 02464 617-795-1968 wab@bodkindesign.com
More informationIMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics
IMAGE FORMATION Light source properties Sensor characteristics Surface Exposure shape Optics Surface reflectance properties ANALOG IMAGES An image can be understood as a 2D light intensity function f(x,y)
More informationECEN 4606, UNDERGRADUATE OPTICS LAB
ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 3: Imaging 2 the Microscope Original Version: Professor McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create highly
More informationCameras. CSE 455, Winter 2010 January 25, 2010
Cameras CSE 455, Winter 2010 January 25, 2010 Announcements New Lecturer! Neel Joshi, Ph.D. Post-Doctoral Researcher Microsoft Research neel@cs Project 1b (seam carving) was due on Friday the 22 nd Project
More informationChapter 25 Optical Instruments
Chapter 25 Optical Instruments Units of Chapter 25 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying Glass Telescopes Compound Microscope Aberrations of Lenses and Mirrors Limits of
More informationCODE V Introductory Tutorial
CODE V Introductory Tutorial Cheng-Fang Ho Lab.of RF-MW Photonics, Department of Physics, National Cheng-Kung University, Tainan, Taiwan 1-1 Tutorial Outline Introduction to CODE V Optical Design Process
More informationR I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS
Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Wyko RST Plus. All users are expected to have read and understood this document.
More informationCalibration Report. Vexcel Imaging GmbH, A-8010 Graz, Austria
Calibration Report Camera: Manufacturer: UltraCam D, S/N UCD-SU-1-0031 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Apr-10-2009 Date of Report: Feb-15-2010 Camera Revision: 4.0 Revision
More informationGentec Electro-Optics, Inc
Gentec Electro-Optics, Inc. 2013. Accessories for Beam Diagnostics Revision 2.0 2 WARRANTY The Gentec-EO accessories for beam diagnostics carry a one-year warranty (from date of shipment) against material
More informationAdaptive Optics for LIGO
Adaptive Optics for LIGO Justin Mansell Ginzton Laboratory LIGO-G990022-39-M Motivation Wavefront Sensor Outline Characterization Enhancements Modeling Projections Adaptive Optics Results Effects of Thermal
More informationNikon 200mm f/4d ED-IF AF Micro Nikkor (Tested)
Nikon 200mm f/4d ED-IF AF Micro Nikkor (Tested) Nikon 200mm f/4d ED-IF AF Micro Nikkor Image Circle 35mm Type Telephoto Prime Macro Focal Length 200mm APS Equivalent 300mm Max Aperture f/4 Min Aperture
More informationCalibration Report. Short version. UltraCam X, S/N UCX-SX Microsoft Photogrammetry, A-8010 Graz, Austria. ( 1 of 13 )
Calibration Report Short version Camera: Manufacturer: UltraCam X, S/N UCX-SX-1-30518177 Microsoft Photogrammetry, A-8010 Graz, Austria Date of Calibration: May-24-2007 Date of Report: Jun-21-2007 Camera
More informationCalibration Report. Short version. UltraCam Xp, S/N UC-SXp Vexcel Imaging GmbH, A-8010 Graz, Austria
Calibration Report Short version Camera: Manufacturer: UltraCam Xp, S/N UC-SXp-1-61212452 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Mar-05-2009 Date of Report: Mar-13-2009 Camera Revision:
More informationUV LED ILLUMINATION STEPPER OFFERS HIGH PERFORMANCE AND LOW COST OF OWNERSHIP
UV LED ILLUMINATION STEPPER OFFERS HIGH PERFORMANCE AND LOW COST OF OWNERSHIP Casey Donaher, Rudolph Technologies Herbert J. Thompson, Rudolph Technologies Chin Tiong Sim, Rudolph Technologies Rudolph
More informationOptoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790
Calibration Standard for Sighting & Imaging Devices 2223 West San Bernardino Road West Covina, California 91790 Phone: (626) 962-5181 Fax: (626) 962-5188 www.davidsonoptronics.com sales@davidsonoptronics.com
More informationOptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses
OptiSpheric IOL Integrated Optical Testing of Intraocular Lenses OPTICAL TEST STATION OptiSpheric IOL ISO 11979 Intraocular Lens Testing OptiSpheric IOL PRO with in air tray on optional instrument table
More informationNew foveated wide angle lens with high resolving power and without brightness loss in the periphery
New foveated wide angle lens with high resolving power and without brightness loss in the periphery K. Wakamiya *a, T. Senga a, K. Isagi a, N. Yamamura a, Y. Ushio a and N. Kita b a Nikon Corp., 6-3,Nishi-ohi
More informationGRINTECH GmbH. product information.
GRINTECH GmbH product information www.grintech.de GRIN rod lenses Gradient index lenses for fiber coupling and beam shaping of laser diodes z l d s f Order example: GT-LFRL-100-025-50-CC (670) Design wavelength
More informationPHY385H1F Introductory Optics. Practicals Session 7 Studying for Test 2
PHY385H1F Introductory Optics Practicals Session 7 Studying for Test 2 Entrance Pupil & Exit Pupil A Cooke-triplet consists of three thin lenses in succession, and is often used in cameras. It was patented
More informationLumenis Array LaserLink Pattern Scanning Laser Technology RETINA
Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA Array LaserLink Pattern Scanning Laser Technology Pattern Scanning Laser can reduce photocoagulation treatment time by as much as 60% Pattern
More informationOptical Requirements
Optical Requirements Transmission vs. Film Thickness A pellicle needs a good light transmission and long term transmission stability. Transmission depends on the film thickness, film material and any anti-reflective
More information( ) Deriving the Lens Transmittance Function. Thin lens transmission is given by a phase with unit magnitude.
Deriving the Lens Transmittance Function Thin lens transmission is given by a phase with unit magnitude. t(x, y) = exp[ jk o ]exp[ jk(n 1) (x, y) ] Find the thickness function for left half of the lens
More informationAdvanced Camera and Image Sensor Technology. Steve Kinney Imaging Professional Camera Link Chairman
Advanced Camera and Image Sensor Technology Steve Kinney Imaging Professional Camera Link Chairman Content Physical model of a camera Definition of various parameters for EMVA1288 EMVA1288 and image quality
More informationFast Laser Raman Microscope RAMAN
Fast Laser Raman Microscope RAMAN - 11 www.nanophoton.jp Fast Raman Imaging A New Generation of Raman Microscope RAMAN-11 developed by Nanophoton was created by combining confocal laser microscope technology
More informationParallel Mode Confocal System for Wafer Bump Inspection
Parallel Mode Confocal System for Wafer Bump Inspection ECEN5616 Class Project 1 Gao Wenliang wen-liang_gao@agilent.com 1. Introduction In this paper, A parallel-mode High-speed Line-scanning confocal
More informationUsing Stock Optics. ECE 5616 Curtis
Using Stock Optics What shape to use X & Y parameters Please use achromatics Please use camera lens Please use 4F imaging systems Others things Data link Stock Optics Some comments Advantages Time and
More informationGentec Electro-Optics, Inc
Gentec Electro-Optics, Inc. 2013. Accessories for Beam Diagnostics Revision 1.2 2 WARRANTY The Gentec-EO accessories for beam diagnostics carry a one-year warranty (from date of shipment) against material
More informationa) How big will that physical image of the cells be your camera sensor?
1. Consider a regular wide-field microscope set up with a 60x, NA = 1.4 objective and a monochromatic digital camera with 8 um pixels, properly positioned in the primary image plane. This microscope is
More informationOptical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation
Optical Performance of Nikon F-Mount Lenses Landon Carter May 11, 2016 2.671 Measurement and Instrumentation Abstract In photographic systems, lenses are one of the most important pieces of the system
More informationPROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP
PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Automated asphere centration testing with AspheroCheck UP F. Hahne, P. Langehanenberg F. Hahne, P. Langehanenberg, "Automated asphere
More informationA broadband achromatic metalens for focusing and imaging in the visible
SUPPLEMENTARY INFORMATION Articles https://doi.org/10.1038/s41565-017-0034-6 In the format provided by the authors and unedited. A broadband achromatic metalens for focusing and imaging in the visible
More informationThree-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy
Available online at www.sciencedirect.com Physics Procedia 19 (2011) 291 295 International Conference on Optics in Precision Engineering and Nanotechnology Three-dimensional quantitative phase measurement
More information