Medical Video 2. Endoscopy Equipment. Bronchoscopy. Colonoscopy. Gastroscopy. Key Points Medical Video 2 - Endoscopy:

Size: px
Start display at page:

Download "Medical Video 2. Endoscopy Equipment. Bronchoscopy. Colonoscopy. Gastroscopy. Key Points Medical Video 2 - Endoscopy:"

Transcription

1 Medical Video 2 Endoscopy Equipment D. J. McMahon rev cewood Key Points Medical Video 2 - Endoscopy: Know the proper installation and hazards associated with xenon lamps Know what an insufflator is and what it does Know the medical gas used for ensufflation Know 4 ways to archive video images Understand what a Charge-Coupled Device (CCD) digital video chip is OUTLINE: - Endoscope: for colonoscopy, gastroscopy, bronchoscopy - Camera - CCD charge-coupled device (imaging chip) - Camera Processor - Light Source: xenon lamp or LED - Display - Recording Methods: video tape (no longer used) make a hard copy make a digital video disc (DVD) send it to a flash drive send it to a server for later retrieval - Insufflator - Surgical Microscopes - Test Equipment Colonoscopy Bronchoscopy Gastroscopy

2 Endoscopic Systems The Essentials: > camera > endoscope > light source > camera processor > display Endoscopic Cameras - Charge-Coupled Device (CCD) The heart of solid state imaging much more:

3 Single-Chip Cameras Single-chip cameras use a Bayer filter, which allows them to detect only one-third of the color information for each pixel on the CCD. The other two-thirds must be interpolated, resulting in a lower effective resolution Bayer filter Three-Chip Cameras Three-chip cameras use a prism to split the image into each of the three primary colors, each of which is received by every pixel on a separate CCD or CMOS camera, giving better resolution and sharpness. Philips type trichroic beam splitter prism Endoscopic Light Sources - use a watt xenon lamp - color balanced to 6500 K - power supply ignites the lamp with a brief pulse in KV range - light output is varied with a mechanical shutter - lots of heat generated

4 Changing Xenon Lamps in Light Sources > Xe Lamps are ~$300. Be sure the lamp needs changing! > Do NOT touch the lens of the lamp with your fingers. > Heat sink compound is essential to maximum lamp life. - clean most of the old compound from the heat sink parts. - apply a thin layer of new heat compound to the contacting surfaces. > Xe lamps have high internal pressure. - should wear eye protection when handling. Handle with care even when discarding. > Good practice to vent the lamp before discarding. Thermal compound: thick liquid of electrically conductive AND thermally conductive material. Typical materials are aluminum oxide, boron nitride, zinc oxide, and aluminum nitride. Newer endoscope light sources use LEDs: Enhanced imaging for endoscopy - Same output (lumens) as xenon lamps Adjustable color & color temperature Much cooler Much more efficient Typical image of an esophagus under normal light.

5 Surgical Microscopes - - Configurable for one to three surgeons - Integrate optics, a light source, and video - Are very expensive Same image under Olympus Narrow Band Imaging. Specific color wavelengths are filtered to emphasize features of human tissue. - Almost always maintained and repaired by a company FSE, but - CE needs to troubleshoot and replace lamps Leica OH5 Endoscopic Systems Ancillary Devices: > insufflator > video tape recorder > video printer > digital storage device(s)

6 Insufflators - create a space in the abdomen for endoscopic procedures with carefully regulated CO 2 typical pressure in the range of mmhg within the abdomen usually display pressure, flow, and total volume of CO 2 used Archiving the images: - put it on video tape (no longer used) - make a hard copy (still images only) - make a digital video disc (DVD) (better) - send it to a flash drive (even better) - send it to a server for later retrieval (best)

7 DVD+R, DVD+RW, DVD-R, DVD-RW: R means recordable once RW means re-recordable (Read-Writeable)..R discs record data once, then act as DVD-ROMs...RW discs can record and erase multiple times, so act as a DVD-RAM. Major Players in Medical Video Systems : Stryker Olympus Conmed-Linvatec Karl Storz Medical Video Monitors: Sony, NDC, Planar, many others Video display pattern generators Sencore video display test equipment:

8 Flexible Endoscopes Typical endoscope cross-section:

9 Joint Commission requirements for endoscopy: EC : - CE must inventory all endoscopes - CE must document all maintenance on endoscopes - but CE is not obligated to perform that maintenance. Endoscope processing is done by the user department in almost every setting. However, CE usually takes care of the endoscope processors. ECRI: Top 10 Health Technology Hazards for 2016 #1: Inadequate Cleaning of Flexible Endoscopes before Disinfection Can Spread Deadly Pathogens Summary The failure to adequately reprocess contaminated instruments that is, to clean and disinfect or sterilize them before using them on subsequent patients can lead to the spread of deadly pathogens. A key aspect of effective reprocessing is cleaning biologic debris and other foreign material from instruments before the disinfection or sterilization step. If this precleaning is not carried out effectively, the disinfection or sterilization step may not be effective. Flexible endoscopes in general, and duodenoscopes in particular, are of specific concern because their complex design and long, narrow channels can make effective cleaning difficult. A series of fatal carbapenem-resistant Enterobacteriaceae (CRE) infections that attracted a lot of attention in 2014 and 2015 illustrates this concern: The deaths were associated with the use of duodenoscopes that had not been successfully disinfected between uses. Facilities need to emphasize to their reprocessing staff that inattention to the cleaning steps within the reprocessing protocol can lead to deadly infections.

Endoscopy Equipment. D. J. McMahon rev cewood

Endoscopy Equipment. D. J. McMahon rev cewood Endoscopy Equipment D. J. McMahon 150512 rev cewood 2018-01-29 Key Points Medical Video 2 - Endoscopy: Know the proper installation and hazards associated with xenon lamps Know what an insufflator is and

More information

Electrosurgery Units (ESU s) and their variants

Electrosurgery Units (ESU s) and their variants Electrosurgery Units (ESU s) and their variants Key Points Electrosurgical Units: - typical output frequency of modern ESU s (450-500 khz, but can be up to 5 MHz) higher frequency makes finer cut with

More information

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003 Ayuekanbe Atagabe Physics 464(applied Optics) Winter 2003 Project Report Fiber Optics in Medicine March 11, 2003 Abstract: Fiber optics have become very important in medical diagnoses in this modern era

More information

Our focus is surgical headlights Endovision.com.au

Our focus is surgical headlights Endovision.com.au LED-9500 HEADLIGHT SYSTEM This is the product surgeons have been waiting for. The Surgical LED Headlight that offers portability, quality light and brightness to match. With the new 70,000 LUX output,

More information

Advancing the Art of Endoscopy

Advancing the Art of Endoscopy Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,

More information

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood Electrosurgery Units (ESU s) and their variants D. J. McMahon 150107 rev cewood 2017-12-23 Key Points Electrosurgical Units: - typical output frequency of modern ESU s (450-500 khz, but can be up to 5

More information

Urban Legends: What You Don t Know Can Hurt You

Urban Legends: What You Don t Know Can Hurt You Urban Legends: What You Don t Know Can Hurt You Objectives 1. Identify urban legends as they pertain to instrumentation. 2. Discuss how design limitations impact performance of instrumentation. 3. Identify

More information

Advancing the Art of Endoscopy

Advancing the Art of Endoscopy Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,

More information

Real-Time in vivo Observation of Cells and Nuclei Opens New Possibilities for Diagnostic Endoscopy

Real-Time in vivo Observation of Cells and Nuclei Opens New Possibilities for Diagnostic Endoscopy Beyond Imagination Introducing Endocyto, Olympus has broken a new ground in endoscopy. Ultra-high magnification with up to 520x magnification ratio enables observation on microscopic level and helps to

More information

GYN / US. VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room

GYN / US. VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room GYN 1.0 03/2016-6-US VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room The VITOM System for your Exoscopy in the Operating Room Dear Colleagues, When feasible, the vaginal

More information

Crossfire Footswitch. User Guide

Crossfire Footswitch. User Guide Crossfire Footswitch 0475000100 User Guide Contents Warnings and Cautions... 3 Symbol Glossary... 4 Product Description and Intended Use... 6 System Overview...6 Indications/Contraindications...8 Package

More information

Basic Users Manual for Tecnai-F20 TEM

Basic Users Manual for Tecnai-F20 TEM Basic Users Manual for Tecnai-F20 TEM NB: This document contains my personal notes on the operating procedure of the Tecnai F20 and may be used as a rough guide for those new to the microscope. It may

More information

SECTION 2. VISUAL INSPECTION

SECTION 2. VISUAL INSPECTION SECTION 2. VISUAL INSPECTION 5-15. GENERAL. Visual inspection is the oldest and most common form of NDI for aircraft. Approximately 80 percent of all NDI procedures are accomplished by the direct visual

More information

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor Image acquisition Digital images are acquired by direct digital acquisition (digital still/video cameras), or scanning material acquired as analog signals (slides, photographs, etc.). In both cases, the

More information

SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk.

SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk. Instructions for use DESCRIPTION: SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk. Silk suture is a nonabsorbable sterile surgical suture composed of an organic protein called fibroin. This

More information

X-Rays and endoscopes

X-Rays and endoscopes X-Rays and endoscopes 1 What are X-rays? X-ray refers to electromagnetic radiation with a wavelength between 0.01nm - 10nm. increasing wavelength visible light ultraviolet x-ray increasing energy X-rays

More information

THEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS...

THEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS... The optimal type for every application 12 12 1 1 8 8 6 6 4 4 2 2 3 35 4 45 5 55 6 65 7 Xenon puls: For reprographic camera type KX... 3 32 34 36 38 4 42 44 46 48 5 52 54 56 58 6 Hg undoped: For UV curing

More information

Diamond-Gerjy Proktoskop

Diamond-Gerjy Proktoskop Assortment surgery 2 A1511 Diamond-Gerjy Proktoskop It has never been easier Wing Plast s Diamond-Gerjy Proctoscope with universal light adapter is made from a clear, environmentally friendly plastic and

More information

Novel Endoscopic Imaging Techniques

Novel Endoscopic Imaging Techniques ENDOSCOPY 2006 152nd Falk Symposium, Berlin May 4-5, 2006 Novel Endoscopic Imaging Techniques Paul Fockens, MD PhD Academic Medical Center, University of Amsterdam Novel Endoscopic Imaging Techniques Current

More information

Video Microscopy of Selective Laser Sintering. Abstract

Video Microscopy of Selective Laser Sintering. Abstract Video Microscopy of Selective Laser Sintering Lawrence S. Melvin III, Suman Das, and Joseph J. Beaman Jr. Department of Mechanical Engineering The University of Texas at Austin Abstract This paper presents

More information

Lecture 20: Optical Tools for MEMS Imaging

Lecture 20: Optical Tools for MEMS Imaging MECH 466 Microelectromechanical Systems University of Victoria Dept. of Mechanical Engineering Lecture 20: Optical Tools for MEMS Imaging 1 Overview Optical Microscopes Video Microscopes Scanning Electron

More information

ENDOSCOPE IN NEUROSURGERY. Presented by: Geetika Madan

ENDOSCOPE IN NEUROSURGERY. Presented by: Geetika Madan ENDOSCOPE IN NEUROSURGERY Presented by: Geetika Madan Endoscopy - 1805 ü Refers to looking inside ü Endoscope is used to illuminate, examine and document difficult to access areas ü Enables the surgeon

More information

C506-E064. Full digital system. Printed in Japan A-NS

C506-E064. Full digital system. Printed in Japan A-NS C506-E064 Full digital system Printed in Japan 6295-08807-30A-NS Full digital system Highest Image Quality in Its Class Comprehensive Full-Digital System FLEXAVISION is a full-digital R/F system equipped

More information

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

RAISING THE LEVEL OF PROTECTION IN YOUR ORS Outpatient Supplement to www outpatientsurgery.net Surgery R October 2009 Magazine 2009-10 Manager s Guide to Patient Safety RAISING THE LEVEL OF PROTECTION IN YOUR ORS E L E C T R O S U R G E R Y S A

More information

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation I. Mantouvalou, K. Witte, R. Jung, J. Tümmler, G. Blobel, H. Legall,

More information

Physics limited resolution of videoscopes Pushing the limits of resolution and why optics know-how is now critical

Physics limited resolution of videoscopes Pushing the limits of resolution and why optics know-how is now critical Physics limited resolution of videoscopes Pushing the limits of resolution and why optics know-how is now critical Frank Lafleur Product Manager Feb 2, 2017 How does Olympus lead in the world of optics

More information

Cameras CS / ECE 181B

Cameras CS / ECE 181B Cameras CS / ECE 181B Image Formation Geometry of image formation (Camera models and calibration) Where? Radiometry of image formation How bright? What color? Examples of cameras What is a Camera? A camera

More information

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Geospatial Systems, Inc (GSI) MS 3100/4100 Series 3-CCD cameras utilize a color-separating prism to split broadband light entering

More information

Hy LED 9 Series LED Surgical Lights

Hy LED 9 Series LED Surgical Lights Technical Specifications Central illuminance (at 1m distance) Light field diameter(at 1m distance)* Depth of illumination (L1+L2) Correlated Color Temperature * Color rendering index Shadow dilution with

More information

HOLOGRAPHY All rights Reserved. Page 3923

HOLOGRAPHY All rights Reserved. Page 3923 HOLOGRAPHY G.A.HARINI B.Tech Student, Department of CSE, Sphoorthy Engineering College, Nadergul(Vill),Sagar Road, Saroonagar(Mdl),R.R Dist.T.S. T.SOMA SHEKAR Associate Professor, Department of CSE, Sphoorthy

More information

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

LaserBeam ProfilingSolutions. IRLaserBeam Profiler LaserBeam ProfilingSolutions IRLaserBeam Profiler TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 TECHNICAL DATA DIMENSIONS LASERDEC CL500 TECHNICAL DATA DIMENSIONS LASERDEC CR200 TECHNICAL DATA DIMENSIONS

More information

8 TONNE LOG SPLITTER

8 TONNE LOG SPLITTER 8 TONNE LOG SPLITTER MODEL NO: LOGBUSTER 9 PART NO: 3402043 OPERATION & MAINTENANCE INSTRUCTIONS LS03/16 INTRODUCTION Thank you for purchasing this CLARKE 8 Tonne Log Splitter. Before attempting to use

More information

Efficient Lighting in. Medical Technology

Efficient Lighting in. Medical Technology Volpi AG Faseroptik Optik Opto-Elektronik Engineering Efficient Lighting in Medical Technology Dipl.Phys. Reinhard Jenny / 03.11.2010 Volpi AG 1 Lighting Lighting in general associated with illumination

More information

BASICS OF FLUOROSCOPY

BASICS OF FLUOROSCOPY Medical Physics Residents Training Program BASICS OF FLUOROSCOPY Dr. Khalid Alyousef, PhD Department of Medical Imaging King Abdulaziz Medical City- Riyadh Edison examining the hand of Clarence Dally with

More information

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast The XLB-2500 Xenon lamp ballast is a very compact power supply designed for OEM applications. The XLB-2500 is ideal for high power applications where economy

More information

System and method for subtracting dark noise from an image using an estimated dark noise scale factor

System and method for subtracting dark noise from an image using an estimated dark noise scale factor Page 1 of 10 ( 5 of 32 ) United States Patent Application 20060256215 Kind Code A1 Zhang; Xuemei ; et al. November 16, 2006 System and method for subtracting dark noise from an image using an estimated

More information

New Fujinon Z-Series Fiberscopes Ligh Accurate Image and Durability. Everythin

New Fujinon Z-Series Fiberscopes Ligh Accurate Image and Durability. Everythin New Fujinon Z-Series Fiberscopes Ligh Accurate Image and Durability. Everythin Our new fiberoptic endoscope series comes with 30 years of experience and leadership in virtually every phase of optics, electronics

More information

minniescope TM -XS - videoscope with illumination; up to 1Mpixel resolution, under 1.4mm OD for medical or industrial applications

minniescope TM -XS - videoscope with illumination; up to 1Mpixel resolution, under 1.4mm OD for medical or industrial applications DATA SHEET - videoscope with illumination; up to 1Mpixel resolution, under 1.4mm OD for medical or industrial applications introduction: With a distal tip diameter of less than 1.4mm, the is the world

More information

Vocabulary. Unit 9 Forms of Energy. ENERGY: The capacity for doing work.

Vocabulary. Unit 9 Forms of Energy. ENERGY: The capacity for doing work. Unit 9 Forms of Energy Main Idea: There are many forms of energy, including radiant energy and chemical energy. Energy can change form. ENERGY: The capacity for doing work. Heat, Light and Radiant Energy

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS FOOT OPERATED 1.5 TONNE LOG SPLITTER MODEL NO: LOGBUSTER 10 PART NO: 3402046 OPERATION & MAINTENANCE INSTRUCTIONS LS0815 INTRODUCTION Thank you for purchasing this CLARKE Foot Operated 1.5 Tonne Log Splitter.

More information

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View Product Information Version 1.0 ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View ZEISS Axiocam 503 color Sensor Model

More information

LedEngin, Inc. High Efficacy 365nm UV LED Emitter LZ1-00U605. Key Features. Typical Applications. Description

LedEngin, Inc. High Efficacy 365nm UV LED Emitter LZ1-00U605. Key Features. Typical Applications. Description High Efficacy 365nm UV LED Emitter LZ1-00U605 Key Features High Efficacy 365nm 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal

More information

INSTRUCTION MANUAL INF Fax: (503)

INSTRUCTION MANUAL INF Fax: (503) INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi

More information

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast 26 Ward Hill Dr., Bradford, MA 01835 Phone: +1-978-241-8260 Fax: +1-978-241-8262 USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast The XLB-650 Xenon lamp ballast is a very compact power supply designed

More information

Flexible Endoscopy Troubleshooting Guide

Flexible Endoscopy Troubleshooting Guide Flexible Endoscopy Troubleshooting Guide No Air / Water From the Scope 1. Check that the air pump is turned on at the light source 2. Check that the scope is plugged in well to the light source 3. Check

More information

Horizon. Your innovative partner in medicine technology.

Horizon. Your innovative partner in medicine technology. Horizon Valve Channel - Minimally Invasive Valve Surgery Original, Advanced, The Next Generation, Accessories, Sterilisation Container Your innovative partner in medicine technology. micvision.indd 1 08.10.2009

More information

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS MICROWAVE DIATHERMY AND SURGICAL DIATHERMY 1 Microwave diathermy Microwave diathermy uses microwaves to generate heat in the body. It can be used to evenly warm deep tissues without heating the skin. Microwave

More information

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features DATASHEET Lighting Solutions XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features Color Rendering Index (CRI) over 90 with R9 values typically over 80 Bright Light intensity is

More information

1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer.

1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer. Disclaimer: As a condition to the use of this document and the information contained herein, the SWGIT requests notification by e-mail before or contemporaneously to the introduction of this document,

More information

Operating Light marled V10 / V10 Ceiling

Operating Light marled V10 / V10 Ceiling marled V10 / V10 Ceiling Mechanical Design Ceiling-mounted operating light consisting of ceiling tube, horizontal arm, spring arm, cardanic suspension and light head. Mounting is accomplished by means

More information

Smooth, Quick, Responsive Tip Angulation. Light-weight Type Eyepiece. Reliable, Durable Operation

Smooth, Quick, Responsive Tip Angulation. Light-weight Type Eyepiece. Reliable, Durable Operation Fujinon Z-Series Fiberscopes Light W Accurate Image and Durability. Everythin Our new fiberoptic endoscope series comes with more than 30 years of experience and leadership in virtually every phase of

More information

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V FastGene FAS-V Imaging System Catalogue Number GP-FAS-V Content 1. SAFETY INFORMATION 3 2. WARRANTY 3 3. CONTACT DETAILS 3 4. REGULATORY NOTICE 4 5. IMPORTANT NOTICE 4 6. SPECIFICATION 5 7. NOMENCLATURE

More information

LumiBright TM LE 2400B-270

LumiBright TM LE 2400B-270 solutions in light LumiBright TM LE 2400B-270 2400B-270 Compact Light Engines provide extreme brightness and a highly uniform light distribution. Chip-on-Board LED technology with metallic PCB substrates

More information

Lecture 29: Image Sensors. Computer Graphics and Imaging UC Berkeley CS184/284A

Lecture 29: Image Sensors. Computer Graphics and Imaging UC Berkeley CS184/284A Lecture 29: Image Sensors Computer Graphics and Imaging UC Berkeley Photon Capture The Photoelectric Effect Incident photons Ejected electrons Albert Einstein (wikipedia) Einstein s Nobel Prize in 1921

More information

gsource stitch scissors - 15/1 Spencer Stitch Scissors Shortbent Stitch Scissors Northbent Stitch Scissors Angled Stitch Scissors

gsource stitch scissors - 15/1 Spencer Stitch Scissors Shortbent Stitch Scissors Northbent Stitch Scissors Angled Stitch Scissors stitch scissors - /1 gs.1680 3 1/2" gs.1920 5" gs.1800 3 1/2" Spencer Stitch Scissors delicate hooked blade Shortbent Stitch Scissors delicate hooked blade gs.1950 4 1/2" gs.2040 4 3/4" Angled Stitch Scissors

More information

EPX-3500 HD FUJIFILM High-end Electronic Video Endoscopy System

EPX-3500 HD FUJIFILM High-end Electronic Video Endoscopy System New EPX-3500 HD FUJIFILM High-end Electronic Video Endoscopy System FUJIFILM Asia Pacific Pte. Ltd. 10 New Industrial Road, FUJIFILM Building, Singapore 536201 http://www.fujifilm.com.sg High-definition

More information

Lenses. A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope

Lenses. A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope SNC2D Lenses A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope Reading stones used by monks, nuns, and scholars ~1000 C.E. Lenses THERE ARE

More information

The end-to-end joining of coils of strip has grown in

The end-to-end joining of coils of strip has grown in Coil-to-coil joining with laser welding The combination of steel strip edge preparation via laser cutting, accurate strip positioning systems, and laser welding in a single unit provides the optimum coil-to-coil

More information

High Efficacy 365nm UV LED Emitter LZ1-00U600

High Efficacy 365nm UV LED Emitter LZ1-00U600 High Efficacy 365nm UV LED Emitter LZ1-U6 Key Features High Efficacy 365nm 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal

More information

Microscope-Spectrometer

Microscope-Spectrometer 20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments

More information

OPTIVISTA TM EPK-i7010

OPTIVISTA TM EPK-i7010 OPTIVIST TM EPK-i7010 unique combination of optical and digital enhancement in one endoscopy processor Courtesy of Dr. Federico uffoli, Cremona Hospital, Italy PENTX MEDICL OPTIVIST TM EPK-i7010 Enlighten

More information

Digital Imaging Group. 20th June Working at the High End

Digital Imaging Group. 20th June Working at the High End Digital Imaging Group 20th June 2014 Working at the High End Processing RAW files in Adobe Camera Raw (ACR) (and a little about high pixel count cameras later) What is RAW? The RAW file captures information

More information

minniecamtm -XS; up to 1Mpixel resolution, under 1.35mm OD for medical or industrial applications

minniecamtm -XS; up to 1Mpixel resolution, under 1.35mm OD for medical or industrial applications DATA SHEET ; up to 1Mpixel resolution, under 1.35mm OD for medical or industrial applications introduction: With a package footprint of less than 0.95mmx0.95mm, the is the world s smallest imaging sensor

More information

Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E

Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E Surgical Handpiece Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93 S-Max SG20 09.03.01 M OM-C0425E 001 for X-SG20L,SG20 This handpiece is used only for the Surgical Unit with Torque Calibration

More information

Lecture PowerPoint. Chapter 25 Physics: Principles with Applications, 6 th edition Giancoli

Lecture PowerPoint. Chapter 25 Physics: Principles with Applications, 6 th edition Giancoli Lecture PowerPoint Chapter 25 Physics: Principles with Applications, 6 th edition Giancoli 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the

More information

Operating Light marled V16 / V16 D

Operating Light marled V16 / V16 D marled V16 / V16 D Mechanical Design Operating light system for ceiling installation, consisting of ceiling tube, horizontal cantilevers, spring arms, cardan joint and light bodies. Depending on the situation

More information

Lumencor White Paper: Solid state light engines for bioanalytical instruments and biomedical devices

Lumencor White Paper: Solid state light engines for bioanalytical instruments and biomedical devices lumencor Lumencor White Paper: Solid state light engines for bioanalytical instruments and biomedical devices Prepared by: Claudia B. Jaffe, Ph.D., Vice President, Business Development and Steven M. Jaffe,

More information

Putting It All Together: Computer Architecture and the Digital Camera

Putting It All Together: Computer Architecture and the Digital Camera 461 Putting It All Together: Computer Architecture and the Digital Camera This book covers many topics in circuit analysis and design, so it is only natural to wonder how they all fit together and how

More information

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR

More information

Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION

Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION AGILENT CARY 610/620 FTIR MICROSCOPES ADVANCING FTIR MICROSCOPY AND IMAGING Agilent s 610/620 FTIR microscopes

More information

Megapixels and more. The basics of image processing in digital cameras. Construction of a digital camera

Megapixels and more. The basics of image processing in digital cameras. Construction of a digital camera Megapixels and more The basics of image processing in digital cameras Photography is a technique of preserving pictures with the help of light. The first durable photograph was made by Nicephor Niepce

More information

Directions for Use. Veinlite A. TransLite, LLC.

Directions for Use. Veinlite A. TransLite, LLC. Directions for Use Veinlite A TransLite, LLC www.veinlite.com IMPORTANT: Veinlite A is a device which allows the medical practitioner to better visualize superficial veins. This information should be incorporated

More information

Compact High Intensity Light Source

Compact High Intensity Light Source Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc

More information

Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode. Alex Grammar

Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode. Alex Grammar Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode Alex Grammar Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode Alex Grammar Advised by Dr.

More information

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4 10 72810 Gomaringen I Germany Phone +49 (0)7072-6002-0 Fax +49 (0)7072-6002-33 info@bowa-medical.com I bowa-medical.com 10757 4 02/09 Printed in Germany

More information

Designed to improve physician productivity and patient care.

Designed to improve physician productivity and patient care. Designed to improve physician productivity and patient care. Fujinon s most advanced 400 Video Bronchoscopes are designed for physician productivity and patient care. Advanced miniature chip technology

More information

How does prism technology help to achieve superior color image quality?

How does prism technology help to achieve superior color image quality? WHITE PAPER How does prism technology help to achieve superior color image quality? Achieving superior image quality requires real and full color depth for every channel, improved color contrast and color

More information

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time How to apply Arctic Silver Premium Thermal Adhesive 1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time 5.

More information

LedEngin, Inc. High Efficacy UV LED Emitter LZ1-00UA05. Key Features. Typical Applications. Description

LedEngin, Inc. High Efficacy UV LED Emitter LZ1-00UA05. Key Features. Typical Applications. Description High Efficacy UV LED Emitter LZ1-00UA05 Key Features High Efficacy 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal Resistance

More information

SmartRelease ECTR Endoscopic Carpal Tunnel Release System

SmartRelease ECTR Endoscopic Carpal Tunnel Release System SmartRelease ECTR Endoscopic Carpal Tunnel Release System Instructions for Use PAGE 1 English TABLE OF CONTENTS SYSTEM DESCRIPTION AND INTENDED USE PAGE 1 SMARTRELEASE ECTR SURGICAL INSTRUMENTS AND ACCESSORIES

More information

Where brightness and quality are essential for you Specialty light sources for medical and industrial applications

Where brightness and quality are essential for you Specialty light sources for medical and industrial applications www.osram.com Where brightness and quality are essential for you Specialty light sources for medical and industrial applications Applications Applications The right light for your application Microscopy

More information

Chapter 25 Optical Instruments

Chapter 25 Optical Instruments Chapter 25 Optical Instruments Units of Chapter 25 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying Glass Telescopes Compound Microscope Aberrations of Lenses and Mirrors Limits of

More information

4-dimensional surgical lighting. Surgical lighting

4-dimensional surgical lighting. Surgical lighting 4-dimensional surgical lighting Surgical lighting At STERIS, we haven t tried to produce one lighting system to suit everybody but lighting systems adapted to each of your specialities Jean-Marie L Hégarat

More information

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe Prepared by Genii, Inc. St. Paul, MN, January 2012. (Updated April, 2015) All rights reserved. Introduction

More information

Designed to improve physician productivity and patient care.

Designed to improve physician productivity and patient care. Designed to improve physician productivity and patient care. Fujinon s most advanced Video Bronchoscopes are designed for physician productivity and patient care. Advanced miniature chip technology sets

More information

Adding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices.

Adding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices. Lighting up the OR Adding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices. Anne L. Fischer, Senior Editor, anne.fischer@photonics.com

More information

IR LED Illuminator OW806 OW809 OW812 OW815 IP-138TC5 IP-158SC3 IP-137LP54 IP-007LFP54. Dimensions (mm) LED Type. Angle and Max Input

IR LED Illuminator OW806 OW809 OW812 OW815 IP-138TC5 IP-158SC3 IP-137LP54 IP-007LFP54. Dimensions (mm) LED Type. Angle and Max Input PRODUCT OVERVIEW January 2014 Pictures Max Distance Angle and Max Distance Input LED Type Wavelength IP Weight Dimensions (mm) OW806 160m 15º - 160m 20º - 130m 30º - 100m 40º - 80m 50º - 60m 60º - 40m

More information

VEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63

VEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63 VEXUS TROUBLESHOOTING GUIDE VEXUS E1 EV10C2DB6 / H10C2MR63 VEXUS EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63 MINI SPLIT SYSTEM Troubleshooting Indoor unit error display Display Operation

More information

CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY

CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY Microscope components get dirty with time. Dirt and dust particles on the optical components are especially damaging to image quality. When photographing

More information

Operating Light marled V16 / V10 D

Operating Light marled V16 / V10 D marled V16 / V10 D Mechanical Design Ceiling-mounted operating light consisting of ceiling tube, horizontal arm, spring arm, cardanic suspension and light head. Mounting is accomplished by means of either

More information

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions About Ophir-Spiricon With over 30 years of experience, the Ophir Photonics Group provides a complete line of instrumentation including power and energy meters, beam profilers, spectrum analyzers, and goniometric

More information

LIGHT SOURCE LX 2300 (Xenon 300W)

LIGHT SOURCE LX 2300 (Xenon 300W) LIGHT SOURCE LX 2300 (Xenon 300W) IM 200-300 WA001_ 2006-01-11_MI Summary 1. Warnings and Precautions 2 2. Technical Features 3 3. Principle Plan 4 4. Comprehensive view - Setting up Plan 5 4.1 Filter

More information

Guide to Confocal 5. Starting session

Guide to Confocal 5. Starting session Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope

More information

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 2 1. Components Illustration... 3 2. Installation...

More information

BRAZE INSTRUCTION VIDEO

BRAZE INSTRUCTION VIDEO BRAZE INSTRUCTION VIDEO 1 Purpose: The purpose of this video is to provide instructions, guidelines and examples as to the proper techniques involved in the brazing of diamond cutters into matrix or steel

More information

Digital Camera Sensors

Digital Camera Sensors Digital Camera Sensors Agenda Basic Parts of a Digital Camera The Pixel Camera Sensor Pixels Camera Sensor Sizes Pixel Density CMOS vs. CCD Digital Signal Processors ISO, Noise & Light Sensor Comparison

More information

Applications of Optics

Applications of Optics Nicholas J. Giordano www.cengage.com/physics/giordano Chapter 26 Applications of Optics Marilyn Akins, PhD Broome Community College Applications of Optics Many devices are based on the principles of optics

More information

Double Aperture Camera for High Resolution Measurement

Double Aperture Camera for High Resolution Measurement Double Aperture Camera for High Resolution Measurement Venkatesh Bagaria, Nagesh AS and Varun AV* Siemens Corporate Technology, India *e-mail: varun.av@siemens.com Abstract In the domain of machine vision,

More information

2 PLANMECA. PLANMECA ProSensor. ProSensor

2 PLANMECA. PLANMECA ProSensor. ProSensor NEW 10 YEAR Warranty Program! Cutting-Edge Image Quality The NEW innovative PlaNmEca Digital Intraoral system sets a new standard in dental X-ray imaging. With a unique combination of high-end patient-centered

More information

CHARGE-COUPLED DEVICE (CCD)

CHARGE-COUPLED DEVICE (CCD) CHARGE-COUPLED DEVICE (CCD) Definition A charge-coupled device (CCD) is an analog shift register, enabling analog signals, usually light, manipulation - for example, conversion into a digital value that

More information