Medical Video 2. Endoscopy Equipment. Bronchoscopy. Colonoscopy. Gastroscopy. Key Points Medical Video 2 - Endoscopy:
|
|
- Sophie Todd
- 5 years ago
- Views:
Transcription
1 Medical Video 2 Endoscopy Equipment D. J. McMahon rev cewood Key Points Medical Video 2 - Endoscopy: Know the proper installation and hazards associated with xenon lamps Know what an insufflator is and what it does Know the medical gas used for ensufflation Know 4 ways to archive video images Understand what a Charge-Coupled Device (CCD) digital video chip is OUTLINE: - Endoscope: for colonoscopy, gastroscopy, bronchoscopy - Camera - CCD charge-coupled device (imaging chip) - Camera Processor - Light Source: xenon lamp or LED - Display - Recording Methods: video tape (no longer used) make a hard copy make a digital video disc (DVD) send it to a flash drive send it to a server for later retrieval - Insufflator - Surgical Microscopes - Test Equipment Colonoscopy Bronchoscopy Gastroscopy
2 Endoscopic Systems The Essentials: > camera > endoscope > light source > camera processor > display Endoscopic Cameras - Charge-Coupled Device (CCD) The heart of solid state imaging much more:
3 Single-Chip Cameras Single-chip cameras use a Bayer filter, which allows them to detect only one-third of the color information for each pixel on the CCD. The other two-thirds must be interpolated, resulting in a lower effective resolution Bayer filter Three-Chip Cameras Three-chip cameras use a prism to split the image into each of the three primary colors, each of which is received by every pixel on a separate CCD or CMOS camera, giving better resolution and sharpness. Philips type trichroic beam splitter prism Endoscopic Light Sources - use a watt xenon lamp - color balanced to 6500 K - power supply ignites the lamp with a brief pulse in KV range - light output is varied with a mechanical shutter - lots of heat generated
4 Changing Xenon Lamps in Light Sources > Xe Lamps are ~$300. Be sure the lamp needs changing! > Do NOT touch the lens of the lamp with your fingers. > Heat sink compound is essential to maximum lamp life. - clean most of the old compound from the heat sink parts. - apply a thin layer of new heat compound to the contacting surfaces. > Xe lamps have high internal pressure. - should wear eye protection when handling. Handle with care even when discarding. > Good practice to vent the lamp before discarding. Thermal compound: thick liquid of electrically conductive AND thermally conductive material. Typical materials are aluminum oxide, boron nitride, zinc oxide, and aluminum nitride. Newer endoscope light sources use LEDs: Enhanced imaging for endoscopy - Same output (lumens) as xenon lamps Adjustable color & color temperature Much cooler Much more efficient Typical image of an esophagus under normal light.
5 Surgical Microscopes - - Configurable for one to three surgeons - Integrate optics, a light source, and video - Are very expensive Same image under Olympus Narrow Band Imaging. Specific color wavelengths are filtered to emphasize features of human tissue. - Almost always maintained and repaired by a company FSE, but - CE needs to troubleshoot and replace lamps Leica OH5 Endoscopic Systems Ancillary Devices: > insufflator > video tape recorder > video printer > digital storage device(s)
6 Insufflators - create a space in the abdomen for endoscopic procedures with carefully regulated CO 2 typical pressure in the range of mmhg within the abdomen usually display pressure, flow, and total volume of CO 2 used Archiving the images: - put it on video tape (no longer used) - make a hard copy (still images only) - make a digital video disc (DVD) (better) - send it to a flash drive (even better) - send it to a server for later retrieval (best)
7 DVD+R, DVD+RW, DVD-R, DVD-RW: R means recordable once RW means re-recordable (Read-Writeable)..R discs record data once, then act as DVD-ROMs...RW discs can record and erase multiple times, so act as a DVD-RAM. Major Players in Medical Video Systems : Stryker Olympus Conmed-Linvatec Karl Storz Medical Video Monitors: Sony, NDC, Planar, many others Video display pattern generators Sencore video display test equipment:
8 Flexible Endoscopes Typical endoscope cross-section:
9 Joint Commission requirements for endoscopy: EC : - CE must inventory all endoscopes - CE must document all maintenance on endoscopes - but CE is not obligated to perform that maintenance. Endoscope processing is done by the user department in almost every setting. However, CE usually takes care of the endoscope processors. ECRI: Top 10 Health Technology Hazards for 2016 #1: Inadequate Cleaning of Flexible Endoscopes before Disinfection Can Spread Deadly Pathogens Summary The failure to adequately reprocess contaminated instruments that is, to clean and disinfect or sterilize them before using them on subsequent patients can lead to the spread of deadly pathogens. A key aspect of effective reprocessing is cleaning biologic debris and other foreign material from instruments before the disinfection or sterilization step. If this precleaning is not carried out effectively, the disinfection or sterilization step may not be effective. Flexible endoscopes in general, and duodenoscopes in particular, are of specific concern because their complex design and long, narrow channels can make effective cleaning difficult. A series of fatal carbapenem-resistant Enterobacteriaceae (CRE) infections that attracted a lot of attention in 2014 and 2015 illustrates this concern: The deaths were associated with the use of duodenoscopes that had not been successfully disinfected between uses. Facilities need to emphasize to their reprocessing staff that inattention to the cleaning steps within the reprocessing protocol can lead to deadly infections.
Endoscopy Equipment. D. J. McMahon rev cewood
Endoscopy Equipment D. J. McMahon 150512 rev cewood 2018-01-29 Key Points Medical Video 2 - Endoscopy: Know the proper installation and hazards associated with xenon lamps Know what an insufflator is and
More informationElectrosurgery Units (ESU s) and their variants
Electrosurgery Units (ESU s) and their variants Key Points Electrosurgical Units: - typical output frequency of modern ESU s (450-500 khz, but can be up to 5 MHz) higher frequency makes finer cut with
More informationAyuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003
Ayuekanbe Atagabe Physics 464(applied Optics) Winter 2003 Project Report Fiber Optics in Medicine March 11, 2003 Abstract: Fiber optics have become very important in medical diagnoses in this modern era
More informationOur focus is surgical headlights Endovision.com.au
LED-9500 HEADLIGHT SYSTEM This is the product surgeons have been waiting for. The Surgical LED Headlight that offers portability, quality light and brightness to match. With the new 70,000 LUX output,
More informationAdvancing the Art of Endoscopy
Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,
More informationElectrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood
Electrosurgery Units (ESU s) and their variants D. J. McMahon 150107 rev cewood 2017-12-23 Key Points Electrosurgical Units: - typical output frequency of modern ESU s (450-500 khz, but can be up to 5
More informationUrban Legends: What You Don t Know Can Hurt You
Urban Legends: What You Don t Know Can Hurt You Objectives 1. Identify urban legends as they pertain to instrumentation. 2. Discuss how design limitations impact performance of instrumentation. 3. Identify
More informationAdvancing the Art of Endoscopy
Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,
More informationReal-Time in vivo Observation of Cells and Nuclei Opens New Possibilities for Diagnostic Endoscopy
Beyond Imagination Introducing Endocyto, Olympus has broken a new ground in endoscopy. Ultra-high magnification with up to 520x magnification ratio enables observation on microscopic level and helps to
More informationGYN / US. VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room
GYN 1.0 03/2016-6-US VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room The VITOM System for your Exoscopy in the Operating Room Dear Colleagues, When feasible, the vaginal
More informationCrossfire Footswitch. User Guide
Crossfire Footswitch 0475000100 User Guide Contents Warnings and Cautions... 3 Symbol Glossary... 4 Product Description and Intended Use... 6 System Overview...6 Indications/Contraindications...8 Package
More informationBasic Users Manual for Tecnai-F20 TEM
Basic Users Manual for Tecnai-F20 TEM NB: This document contains my personal notes on the operating procedure of the Tecnai F20 and may be used as a rough guide for those new to the microscope. It may
More informationSECTION 2. VISUAL INSPECTION
SECTION 2. VISUAL INSPECTION 5-15. GENERAL. Visual inspection is the oldest and most common form of NDI for aircraft. Approximately 80 percent of all NDI procedures are accomplished by the direct visual
More informationImage acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor
Image acquisition Digital images are acquired by direct digital acquisition (digital still/video cameras), or scanning material acquired as analog signals (slides, photographs, etc.). In both cases, the
More informationSUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk.
Instructions for use DESCRIPTION: SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk. Silk suture is a nonabsorbable sterile surgical suture composed of an organic protein called fibroin. This
More informationX-Rays and endoscopes
X-Rays and endoscopes 1 What are X-rays? X-ray refers to electromagnetic radiation with a wavelength between 0.01nm - 10nm. increasing wavelength visible light ultraviolet x-ray increasing energy X-rays
More informationTHEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS...
The optimal type for every application 12 12 1 1 8 8 6 6 4 4 2 2 3 35 4 45 5 55 6 65 7 Xenon puls: For reprographic camera type KX... 3 32 34 36 38 4 42 44 46 48 5 52 54 56 58 6 Hg undoped: For UV curing
More informationDiamond-Gerjy Proktoskop
Assortment surgery 2 A1511 Diamond-Gerjy Proktoskop It has never been easier Wing Plast s Diamond-Gerjy Proctoscope with universal light adapter is made from a clear, environmentally friendly plastic and
More informationNovel Endoscopic Imaging Techniques
ENDOSCOPY 2006 152nd Falk Symposium, Berlin May 4-5, 2006 Novel Endoscopic Imaging Techniques Paul Fockens, MD PhD Academic Medical Center, University of Amsterdam Novel Endoscopic Imaging Techniques Current
More informationVideo Microscopy of Selective Laser Sintering. Abstract
Video Microscopy of Selective Laser Sintering Lawrence S. Melvin III, Suman Das, and Joseph J. Beaman Jr. Department of Mechanical Engineering The University of Texas at Austin Abstract This paper presents
More informationLecture 20: Optical Tools for MEMS Imaging
MECH 466 Microelectromechanical Systems University of Victoria Dept. of Mechanical Engineering Lecture 20: Optical Tools for MEMS Imaging 1 Overview Optical Microscopes Video Microscopes Scanning Electron
More informationENDOSCOPE IN NEUROSURGERY. Presented by: Geetika Madan
ENDOSCOPE IN NEUROSURGERY Presented by: Geetika Madan Endoscopy - 1805 ü Refers to looking inside ü Endoscope is used to illuminate, examine and document difficult to access areas ü Enables the surgeon
More informationC506-E064. Full digital system. Printed in Japan A-NS
C506-E064 Full digital system Printed in Japan 6295-08807-30A-NS Full digital system Highest Image Quality in Its Class Comprehensive Full-Digital System FLEXAVISION is a full-digital R/F system equipped
More informationRAISING THE LEVEL OF PROTECTION IN YOUR ORS
Outpatient Supplement to www outpatientsurgery.net Surgery R October 2009 Magazine 2009-10 Manager s Guide to Patient Safety RAISING THE LEVEL OF PROTECTION IN YOUR ORS E L E C T R O S U R G E R Y S A
More informationA novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation
A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation I. Mantouvalou, K. Witte, R. Jung, J. Tümmler, G. Blobel, H. Legall,
More informationPhysics limited resolution of videoscopes Pushing the limits of resolution and why optics know-how is now critical
Physics limited resolution of videoscopes Pushing the limits of resolution and why optics know-how is now critical Frank Lafleur Product Manager Feb 2, 2017 How does Olympus lead in the world of optics
More informationCameras CS / ECE 181B
Cameras CS / ECE 181B Image Formation Geometry of image formation (Camera models and calibration) Where? Radiometry of image formation How bright? What color? Examples of cameras What is a Camera? A camera
More informationSpectral and Polarization Configuration Guide for MS Series 3-CCD Cameras
Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Geospatial Systems, Inc (GSI) MS 3100/4100 Series 3-CCD cameras utilize a color-separating prism to split broadband light entering
More informationHy LED 9 Series LED Surgical Lights
Technical Specifications Central illuminance (at 1m distance) Light field diameter(at 1m distance)* Depth of illumination (L1+L2) Correlated Color Temperature * Color rendering index Shadow dilution with
More informationHOLOGRAPHY All rights Reserved. Page 3923
HOLOGRAPHY G.A.HARINI B.Tech Student, Department of CSE, Sphoorthy Engineering College, Nadergul(Vill),Sagar Road, Saroonagar(Mdl),R.R Dist.T.S. T.SOMA SHEKAR Associate Professor, Department of CSE, Sphoorthy
More informationLaserBeam ProfilingSolutions. IRLaserBeam Profiler
LaserBeam ProfilingSolutions IRLaserBeam Profiler TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 TECHNICAL DATA DIMENSIONS LASERDEC CL500 TECHNICAL DATA DIMENSIONS LASERDEC CR200 TECHNICAL DATA DIMENSIONS
More information8 TONNE LOG SPLITTER
8 TONNE LOG SPLITTER MODEL NO: LOGBUSTER 9 PART NO: 3402043 OPERATION & MAINTENANCE INSTRUCTIONS LS03/16 INTRODUCTION Thank you for purchasing this CLARKE 8 Tonne Log Splitter. Before attempting to use
More informationEfficient Lighting in. Medical Technology
Volpi AG Faseroptik Optik Opto-Elektronik Engineering Efficient Lighting in Medical Technology Dipl.Phys. Reinhard Jenny / 03.11.2010 Volpi AG 1 Lighting Lighting in general associated with illumination
More informationBASICS OF FLUOROSCOPY
Medical Physics Residents Training Program BASICS OF FLUOROSCOPY Dr. Khalid Alyousef, PhD Department of Medical Imaging King Abdulaziz Medical City- Riyadh Edison examining the hand of Clarence Dally with
More informationUSER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast
USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast The XLB-2500 Xenon lamp ballast is a very compact power supply designed for OEM applications. The XLB-2500 is ideal for high power applications where economy
More informationSystem and method for subtracting dark noise from an image using an estimated dark noise scale factor
Page 1 of 10 ( 5 of 32 ) United States Patent Application 20060256215 Kind Code A1 Zhang; Xuemei ; et al. November 16, 2006 System and method for subtracting dark noise from an image using an estimated
More informationNew Fujinon Z-Series Fiberscopes Ligh Accurate Image and Durability. Everythin
New Fujinon Z-Series Fiberscopes Ligh Accurate Image and Durability. Everythin Our new fiberoptic endoscope series comes with 30 years of experience and leadership in virtually every phase of optics, electronics
More informationminniescope TM -XS - videoscope with illumination; up to 1Mpixel resolution, under 1.4mm OD for medical or industrial applications
DATA SHEET - videoscope with illumination; up to 1Mpixel resolution, under 1.4mm OD for medical or industrial applications introduction: With a distal tip diameter of less than 1.4mm, the is the world
More informationVocabulary. Unit 9 Forms of Energy. ENERGY: The capacity for doing work.
Unit 9 Forms of Energy Main Idea: There are many forms of energy, including radiant energy and chemical energy. Energy can change form. ENERGY: The capacity for doing work. Heat, Light and Radiant Energy
More informationOPERATION & MAINTENANCE INSTRUCTIONS
FOOT OPERATED 1.5 TONNE LOG SPLITTER MODEL NO: LOGBUSTER 10 PART NO: 3402046 OPERATION & MAINTENANCE INSTRUCTIONS LS0815 INTRODUCTION Thank you for purchasing this CLARKE Foot Operated 1.5 Tonne Log Splitter.
More informationZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View
Product Information Version 1.0 ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View ZEISS Axiocam 503 color Sensor Model
More informationLedEngin, Inc. High Efficacy 365nm UV LED Emitter LZ1-00U605. Key Features. Typical Applications. Description
High Efficacy 365nm UV LED Emitter LZ1-00U605 Key Features High Efficacy 365nm 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal
More informationINSTRUCTION MANUAL INF Fax: (503)
INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi
More informationUSER MANUAL XLB-650 Short Arc Xenon Lamp Ballast
26 Ward Hill Dr., Bradford, MA 01835 Phone: +1-978-241-8260 Fax: +1-978-241-8262 USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast The XLB-650 Xenon lamp ballast is a very compact power supply designed
More informationFlexible Endoscopy Troubleshooting Guide
Flexible Endoscopy Troubleshooting Guide No Air / Water From the Scope 1. Check that the air pump is turned on at the light source 2. Check that the scope is plugged in well to the light source 3. Check
More informationHorizon. Your innovative partner in medicine technology.
Horizon Valve Channel - Minimally Invasive Valve Surgery Original, Advanced, The Next Generation, Accessories, Sterilisation Container Your innovative partner in medicine technology. micvision.indd 1 08.10.2009
More informationMICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS
MICROWAVE DIATHERMY AND SURGICAL DIATHERMY 1 Microwave diathermy Microwave diathermy uses microwaves to generate heat in the body. It can be used to evenly warm deep tissues without heating the skin. Microwave
More informationOTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features
DATASHEET Lighting Solutions XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features Color Rendering Index (CRI) over 90 with R9 values typically over 80 Bright Light intensity is
More information1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer.
Disclaimer: As a condition to the use of this document and the information contained herein, the SWGIT requests notification by e-mail before or contemporaneously to the introduction of this document,
More informationOperating Light marled V10 / V10 Ceiling
marled V10 / V10 Ceiling Mechanical Design Ceiling-mounted operating light consisting of ceiling tube, horizontal arm, spring arm, cardanic suspension and light head. Mounting is accomplished by means
More informationSmooth, Quick, Responsive Tip Angulation. Light-weight Type Eyepiece. Reliable, Durable Operation
Fujinon Z-Series Fiberscopes Light W Accurate Image and Durability. Everythin Our new fiberoptic endoscope series comes with more than 30 years of experience and leadership in virtually every phase of
More informationFastGene FAS-V Imaging System. Catalogue Number GP-FAS-V
FastGene FAS-V Imaging System Catalogue Number GP-FAS-V Content 1. SAFETY INFORMATION 3 2. WARRANTY 3 3. CONTACT DETAILS 3 4. REGULATORY NOTICE 4 5. IMPORTANT NOTICE 4 6. SPECIFICATION 5 7. NOMENCLATURE
More informationLumiBright TM LE 2400B-270
solutions in light LumiBright TM LE 2400B-270 2400B-270 Compact Light Engines provide extreme brightness and a highly uniform light distribution. Chip-on-Board LED technology with metallic PCB substrates
More informationLecture 29: Image Sensors. Computer Graphics and Imaging UC Berkeley CS184/284A
Lecture 29: Image Sensors Computer Graphics and Imaging UC Berkeley Photon Capture The Photoelectric Effect Incident photons Ejected electrons Albert Einstein (wikipedia) Einstein s Nobel Prize in 1921
More informationgsource stitch scissors - 15/1 Spencer Stitch Scissors Shortbent Stitch Scissors Northbent Stitch Scissors Angled Stitch Scissors
stitch scissors - /1 gs.1680 3 1/2" gs.1920 5" gs.1800 3 1/2" Spencer Stitch Scissors delicate hooked blade Shortbent Stitch Scissors delicate hooked blade gs.1950 4 1/2" gs.2040 4 3/4" Angled Stitch Scissors
More informationEPX-3500 HD FUJIFILM High-end Electronic Video Endoscopy System
New EPX-3500 HD FUJIFILM High-end Electronic Video Endoscopy System FUJIFILM Asia Pacific Pte. Ltd. 10 New Industrial Road, FUJIFILM Building, Singapore 536201 http://www.fujifilm.com.sg High-definition
More informationLenses. A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope
SNC2D Lenses A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope Reading stones used by monks, nuns, and scholars ~1000 C.E. Lenses THERE ARE
More informationThe end-to-end joining of coils of strip has grown in
Coil-to-coil joining with laser welding The combination of steel strip edge preparation via laser cutting, accurate strip positioning systems, and laser welding in a single unit provides the optimum coil-to-coil
More informationHigh Efficacy 365nm UV LED Emitter LZ1-00U600
High Efficacy 365nm UV LED Emitter LZ1-U6 Key Features High Efficacy 365nm 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal
More informationMicroscope-Spectrometer
20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments
More informationOPTIVISTA TM EPK-i7010
OPTIVIST TM EPK-i7010 unique combination of optical and digital enhancement in one endoscopy processor Courtesy of Dr. Federico uffoli, Cremona Hospital, Italy PENTX MEDICL OPTIVIST TM EPK-i7010 Enlighten
More informationDigital Imaging Group. 20th June Working at the High End
Digital Imaging Group 20th June 2014 Working at the High End Processing RAW files in Adobe Camera Raw (ACR) (and a little about high pixel count cameras later) What is RAW? The RAW file captures information
More informationminniecamtm -XS; up to 1Mpixel resolution, under 1.35mm OD for medical or industrial applications
DATA SHEET ; up to 1Mpixel resolution, under 1.35mm OD for medical or industrial applications introduction: With a package footprint of less than 0.95mmx0.95mm, the is the world s smallest imaging sensor
More informationSurgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E
Surgical Handpiece Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93 S-Max SG20 09.03.01 M OM-C0425E 001 for X-SG20L,SG20 This handpiece is used only for the Surgical Unit with Torque Calibration
More informationLecture PowerPoint. Chapter 25 Physics: Principles with Applications, 6 th edition Giancoli
Lecture PowerPoint Chapter 25 Physics: Principles with Applications, 6 th edition Giancoli 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the
More informationOperating Light marled V16 / V16 D
marled V16 / V16 D Mechanical Design Operating light system for ceiling installation, consisting of ceiling tube, horizontal cantilevers, spring arms, cardan joint and light bodies. Depending on the situation
More informationLumencor White Paper: Solid state light engines for bioanalytical instruments and biomedical devices
lumencor Lumencor White Paper: Solid state light engines for bioanalytical instruments and biomedical devices Prepared by: Claudia B. Jaffe, Ph.D., Vice President, Business Development and Steven M. Jaffe,
More informationPutting It All Together: Computer Architecture and the Digital Camera
461 Putting It All Together: Computer Architecture and the Digital Camera This book covers many topics in circuit analysis and design, so it is only natural to wonder how they all fit together and how
More informationSpokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales
Spokane Industries Computed Radiography Implementation Experience David Jolin Technical Sales djolin@spokaneindustries.com Outline Background Our Decision for Computed Radiography Implementation of CR
More informationAgilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION
Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION AGILENT CARY 610/620 FTIR MICROSCOPES ADVANCING FTIR MICROSCOPY AND IMAGING Agilent s 610/620 FTIR microscopes
More informationMegapixels and more. The basics of image processing in digital cameras. Construction of a digital camera
Megapixels and more The basics of image processing in digital cameras Photography is a technique of preserving pictures with the help of light. The first durable photograph was made by Nicephor Niepce
More informationDirections for Use. Veinlite A. TransLite, LLC.
Directions for Use Veinlite A TransLite, LLC www.veinlite.com IMPORTANT: Veinlite A is a device which allows the medical practitioner to better visualize superficial veins. This information should be incorporated
More informationCompact High Intensity Light Source
Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc
More informationRelative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode. Alex Grammar
Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode Alex Grammar Relative Quantum Efficiency Measurements of the ROSS Streak Camera Photocathode Alex Grammar Advised by Dr.
More informationARC 200 HF SURGICAL GENERATOR SIMPLY SAFE
BOWA-electronic GmbH & Co. KG Heinrich-Hertz-Strasse 4 10 72810 Gomaringen I Germany Phone +49 (0)7072-6002-0 Fax +49 (0)7072-6002-33 info@bowa-medical.com I bowa-medical.com 10757 4 02/09 Printed in Germany
More informationDesigned to improve physician productivity and patient care.
Designed to improve physician productivity and patient care. Fujinon s most advanced 400 Video Bronchoscopes are designed for physician productivity and patient care. Advanced miniature chip technology
More informationHow does prism technology help to achieve superior color image quality?
WHITE PAPER How does prism technology help to achieve superior color image quality? Achieving superior image quality requires real and full color depth for every channel, improved color contrast and color
More information1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time
How to apply Arctic Silver Premium Thermal Adhesive 1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time 5.
More informationLedEngin, Inc. High Efficacy UV LED Emitter LZ1-00UA05. Key Features. Typical Applications. Description
High Efficacy UV LED Emitter LZ1-00UA05 Key Features High Efficacy 5W UV LED Ultra-small foot print 4.4mm x 4.4mm x 3.2mm Surface mount ceramic package with integrated glass lens Very low Thermal Resistance
More informationSmartRelease ECTR Endoscopic Carpal Tunnel Release System
SmartRelease ECTR Endoscopic Carpal Tunnel Release System Instructions for Use PAGE 1 English TABLE OF CONTENTS SYSTEM DESCRIPTION AND INTENDED USE PAGE 1 SMARTRELEASE ECTR SURGICAL INSTRUMENTS AND ACCESSORIES
More informationWhere brightness and quality are essential for you Specialty light sources for medical and industrial applications
www.osram.com Where brightness and quality are essential for you Specialty light sources for medical and industrial applications Applications Applications The right light for your application Microscopy
More informationChapter 25 Optical Instruments
Chapter 25 Optical Instruments Units of Chapter 25 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying Glass Telescopes Compound Microscope Aberrations of Lenses and Mirrors Limits of
More information4-dimensional surgical lighting. Surgical lighting
4-dimensional surgical lighting Surgical lighting At STERIS, we haven t tried to produce one lighting system to suit everybody but lighting systems adapted to each of your specialities Jean-Marie L Hégarat
More informationWhite Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe
White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe Prepared by Genii, Inc. St. Paul, MN, January 2012. (Updated April, 2015) All rights reserved. Introduction
More informationDesigned to improve physician productivity and patient care.
Designed to improve physician productivity and patient care. Fujinon s most advanced Video Bronchoscopes are designed for physician productivity and patient care. Advanced miniature chip technology sets
More informationAdding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices.
Lighting up the OR Adding features such as color adjustability poses challenges but can improve the safety of surgeries. Corey Bergad, Luminus Devices. Anne L. Fischer, Senior Editor, anne.fischer@photonics.com
More informationIR LED Illuminator OW806 OW809 OW812 OW815 IP-138TC5 IP-158SC3 IP-137LP54 IP-007LFP54. Dimensions (mm) LED Type. Angle and Max Input
PRODUCT OVERVIEW January 2014 Pictures Max Distance Angle and Max Distance Input LED Type Wavelength IP Weight Dimensions (mm) OW806 160m 15º - 160m 20º - 130m 30º - 100m 40º - 80m 50º - 60m 60º - 40m
More informationVEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63
VEXUS TROUBLESHOOTING GUIDE VEXUS E1 EV10C2DB6 / H10C2MR63 VEXUS EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63 MINI SPLIT SYSTEM Troubleshooting Indoor unit error display Display Operation
More informationCLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY
CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY Microscope components get dirty with time. Dirt and dust particles on the optical components are especially damaging to image quality. When photographing
More informationOperating Light marled V16 / V10 D
marled V16 / V10 D Mechanical Design Ceiling-mounted operating light consisting of ceiling tube, horizontal arm, spring arm, cardanic suspension and light head. Mounting is accomplished by means of either
More informationHow to Avoid Thermal Sensor Damage & Out of Tolerance Conditions
About Ophir-Spiricon With over 30 years of experience, the Ophir Photonics Group provides a complete line of instrumentation including power and energy meters, beam profilers, spectrum analyzers, and goniometric
More informationLIGHT SOURCE LX 2300 (Xenon 300W)
LIGHT SOURCE LX 2300 (Xenon 300W) IM 200-300 WA001_ 2006-01-11_MI Summary 1. Warnings and Precautions 2 2. Technical Features 3 3. Principle Plan 4 4. Comprehensive view - Setting up Plan 5 4.1 Filter
More informationGuide to Confocal 5. Starting session
Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope
More informationUser Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com
User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 2 1. Components Illustration... 3 2. Installation...
More informationBRAZE INSTRUCTION VIDEO
BRAZE INSTRUCTION VIDEO 1 Purpose: The purpose of this video is to provide instructions, guidelines and examples as to the proper techniques involved in the brazing of diamond cutters into matrix or steel
More informationDigital Camera Sensors
Digital Camera Sensors Agenda Basic Parts of a Digital Camera The Pixel Camera Sensor Pixels Camera Sensor Sizes Pixel Density CMOS vs. CCD Digital Signal Processors ISO, Noise & Light Sensor Comparison
More informationApplications of Optics
Nicholas J. Giordano www.cengage.com/physics/giordano Chapter 26 Applications of Optics Marilyn Akins, PhD Broome Community College Applications of Optics Many devices are based on the principles of optics
More informationDouble Aperture Camera for High Resolution Measurement
Double Aperture Camera for High Resolution Measurement Venkatesh Bagaria, Nagesh AS and Varun AV* Siemens Corporate Technology, India *e-mail: varun.av@siemens.com Abstract In the domain of machine vision,
More information2 PLANMECA. PLANMECA ProSensor. ProSensor
NEW 10 YEAR Warranty Program! Cutting-Edge Image Quality The NEW innovative PlaNmEca Digital Intraoral system sets a new standard in dental X-ray imaging. With a unique combination of high-end patient-centered
More informationCHARGE-COUPLED DEVICE (CCD)
CHARGE-COUPLED DEVICE (CCD) Definition A charge-coupled device (CCD) is an analog shift register, enabling analog signals, usually light, manipulation - for example, conversion into a digital value that