Harris County Flood Control District. CAD Standards Manual

Size: px
Start display at page:

Download "Harris County Flood Control District. CAD Standards Manual"

Transcription

1

2 Harris County Flood Control District CAD Standards Manual September 2016

3 HCFCD CAD Standards Manual!"#$ Table of Contents 1.1 INTRODUCTION REFERENCES IMPLEMENTATION PLAN REQUIREMENTS 2.1 HCFCD PROJECT PACKAGE PLAN SETS... 7 FIGURE SAMPLE PLAN SET SURVEY CONTROL GENERAL SHEET CONTENT DRAWING STANDARDS 3.1 LAYERS LETTERING FIGURE TEXT PROPERTIES LEADERS AND DIMENSIONS FIGURE DIMENSION SETTINGS LINE WEIGHTS FIGURE LINE WEIGHTS LINETYPES SYMBOLS AND HATCH PATTERNS FIGURE SYMBOLS, LABELS AND HATCH PATTERNS DRAWING SCALES FIGURE DRAWING SCALES STATIONING DRAWING ORIENTATION MATCH LINES CONTENT - PLAN VIEW CONTENT - PROFILE VIEW CONTENT - CROSS SECTIONS STRUCTURAL AND MISCELLANEOUS DETAIL SHEETS SUBMITTAL REQUIREMENTS 4.1 SOFTWARE AND DATA FORMATS FIGURE SOFTWARE AND DATA FORMATS... 24

4 4.2 HARDCOPY DELIVERABLES ELECTRONIC DELIVERABLES SURVEY DATA CAD SUPPORT DATA SAMPLE PLAN SET

5 1. GENERAL INFORMATION 1.1 INTRODUCTION The Harris County Flood Control District 2016 CAD Standards Manual (Manual) provides a simple, intuitive guideline structured to effectively classify and organize data, yet provide flexibility to accommodate the specific needs of a project. Its purpose is to provide a consistent, uniform appearance when preparing construction drawings and exhibits. Occasional departure from this standard is anticipated, whether dictated by project condition or by outside agency requirement(s). The expectation is for the user to follow the guidelines proposed to the extent feasible in order to provide consistency in the final product. Departures from the standards of this Manual will require a prior written request for approval by HCFCD Project Manager. The influence of the U.S. National CAD Standard (NCS) is evident throughout this document although a majority of the specifications and requirements herein are simply reflections of our industry's local drawing and graphic standards. The NCS was created to encourage a more rational construction regulatory environment. The common language it proposes is a key component of Integrated Project Delivery, the collaborative union of people and practices to optimize project efficiency through all phases of design and construction. 1.2 REFERENCES This Manual is an updated version of the 1997 HCFCD Drawing and Graphic Standards Manual. The Harris County Flood Control District (HCFCD) has largely adopted applicable platforms of the U.S. National CAD Standards as the foundation of our CAD and graphic standards. The National CAD Standard is published by the National Institute of Building Sciences. For spatial data, HCFCD practices are based on local industry standards and current business requirements. The key element of this standardization is the requirement that all geospatial data and applications must be fully compatible with current ESRI or Autodesk geospatial products. CAD drafting and design software requirements are further described in Section IMPLEMENTATION This document is to be used for all new projects initiated with the District. For projects with the District that are already underway, coordinate with the District Project Manager to assess the appropriateness of implementation. It is not the 5

6 intent of this update to cause existing projects to incur additional time or cost, and measures should be taken to avoid such. Reference is made in Section 2.1 and 3.4 towards several additional files that will be made available to the consultants. These additional files are intended to make use of these standards easier, but several were not available at time of issuance of this document. The files will be made available at a future date. 2. PLAN REQUIREMENTS 2.1 HCFCD PROJECT PACKAGE 1. As a courtesy, consultants will be provided electronic media containing the appropriate data to assist in the preparation of the construction plans. Drawing, template, and standards files will be compatible with software versions currently used by the HCFCD. The following is a list of data included: a. A digital copy of the 2016 CAD Standards Manual. b. Digital drawing files (.DWG) of a standard border, completed cover sheet, abbreviation definition sheet, HCFCD standard details, general notes, and standard drawing blocks. c. A digital drawing template file (.DWT) compatible with AutoCAD. This drawing template will include basic layer definitions, dimension styles, and font styles. d. A digital drawing template file (.DWT) compatible with AutoCAD Civil 3D. This drawing template will include basic layer definitions, dimension styles, dimension styles and font styles. It will also contain some basic object and label style definitions for use with Civil 3D applications. e. A digital drawing standards file (.DWS). This drawing standards file shall be used by consultants to review project drawings for compliance with HCFCD drawing and graphic standards prior to submittal. f. The HCFCD standard color table plot file (HCFCD.CTB) for plotting B- sized 11 x17 sheets. g. The HCFCD standard linetype file (HCFCD.lin). h. Custom HCFCD logo (image). 6

7 2.2 PLAN SETS 1. Review and final copies of construction plans shall be produced to scale, appropriate on 11 x17 sheets in PDF and on bond or white Mylar as required per the consultant s contract. 2. Plan sets for typical HCFCD projects contain the following drawings compiled in the order below. A sample plan set is attached for your convenience. FIGURE SAMPLE PLAN SET Cover Sheet General Note Sheet Project Layout Drainage Area Map* Survey Control Map Plan and Profile Sheets Cross- Section Sheets SWPPP Sheets SWPPP Detail Sheets Structural/Misc. Detail Sheets HCFCD Detail Sheets Soil Borings* Note: Exact order to be coordinated with HCFCD Project Manager. * If required by the Project Manager. 2.3 SURVEY CONTROL 1. All survey information shall adhere to Harris County Flood Control District s current surveying standards. 2. All distances shown on the plans shall be surface distances. In the Drawing Notes, include the Project Scale Factor, which can be used to convert to State Plane grid coordinates. 3. Bearing orientation and horizontal grid coordinates are referenced to the Texas State Plane Coordinate System, South Central Zone, NAD 83, 1993 adjustment. 4. Elevation values are referenced to the North American Vertical Datum of 1988 (NAVD- 88), 2001 Adjustment. The Engineer shall coordinate the datum adjustment with the HCFCD Project Manager prior to the start of survey activities. 7

8 5. Project monumentation shall use HCFCD s Floodplain Reference Marks. Locations and data sheets for the monuments can be found at 8

9 2.4 GENERAL SHEET CONTENT 1. All drawings shall include a DATE STAMP that includes the plot date, the drawing path and filename. The date stamp shall be located outside the lower left corner of the drawing border and rotated to An example of this is as follows: 03/01/2016 G:\PROJECTS\123456\DRAWINGS\C- LAYOUT.DWG 2. Include signature blocks for HCFCD, utility companies, and other approving agencies as required. 3. Incorporate the HCFCD emblem within the border of each drawing. An electronic copy (image) of the emblem is available. Joint project drawings may include an image of the identification emblem or logo of each contributor including TSPE Firm Registration Number. (Do not display the image frame of the HCFCD emblem. Set the value of the AutoCAD IMAGEFRAME system variable to zero (0)). 4. Each construction drawing shall have the seal, signature and date of signature of the responsible Engineer in accordance with the Texas Engineering Practice Act and Rules. Use of an electronic seal is expected for providing the highest quality plan set submittal. Electronic sealing needs to be attached in accordance with the Texas Engineering Practice Act and Rules. 5. The project benchmark elevation, location, description, datum and datum adjustment are required on the Survey Control Map. Each plan and profile sheet shall contain benchmark and/or temporary benchmark information closely associated with the information on that sheet. See Section 2.3 Survey Control. 6. Store external reference files in the same folder as the project drawing files or in a subfolder labeled XREFS. 7. Use the Relative Path option to attach external reference files. 8. All externally referenced spatial data (DWG, DGN, PDF, images, etc.) shall be generated, where applicable, attached to the base drawing using coordinates 0,0,0 as the insertion point. 9

10 3. DRAWING STANDARDS 3.1 LAYERS The HCFCD layer standard is based on the drawing layer format promoted by the National CAD Standard (NCS). The NCS format consists of four data fields (Discipline Designator, Major Group, and two Minor Groups), plus a Status field. Each field is separated by a dash for clarity. The Discipline Designator and Major Group fields are mandatory. The Minor Groups and Status field are optional. C - A L G N - C H A N - A N N O - P Discipline Major Group Minor Group Minor Group Status Designator (4 letters) (4 letters) (4 letters) Field (1-2 letters) (1 letter) As a courtesy, HCFCD layer names, properties, and descriptions are defined in the HCFCD drawing template file (.dwt) provided in the project package. It is understood that additional layers other than those defined in the template may be necessary. User- defined layers shall be named using the NCS format and include a brief description prefixed with the category User Defined: making the layer easily identifiable as a non- standard layer and to assist in the review process. A drawing standard file (.dws) derived from the HCFCD drawing template is also included in the project package. Consultants shall use this file to review project drawings for compliance with HCFCD drawing and graphic standards and include the results of the review with the interim and final submittals. 10

11 3.2 LETTERING 1. TEXT HEIGHT Standard text height is 0.07 for most drawing annotation. A minimum height of 0.05 is acceptable when used for special purposes such as for symbols or stacked fractions, and existing text and/or dimensions. A minimum height of 0.03 is acceptable for special purposes such as survey spot elevations. 2. TEXT STYLES The Standard text style shall use the upper case Arial (arial.shx) font. Figure 3.2 can be used as a general text property guide. FIGURE TEXT PROPERTIES EXISTING/PROPOSED TEXT STYLE PRINTED HEIGHT PRINTED WIDTH Proposed text and dimensions ARIAL 0.07" 1.0" Existing text and dimensions ARIAL 0.05" 1.0" Major title block text ARIAL 0.10" 1.0" Survey spot elevations ARIAL Sheet numbers, detail titles, section or detail call outs, match line labels, table and location map sub- titles, and column headings Stacked fractions, symbols, small detail annotation ARIAL 0.12" 1.0" ARIAL 0.05" 1.0" Cover sheet title ARIAL BOLD 0.30" 1.0" Cover sheet sub- titles ARIAL BOLD 0.16" 1.0" 11

12 3.3 LEADERS AND DIMENSIONS 1. Leaders shall use straight leader lines and closed, filled arrows. 2. The preferred leader style shall attach the leader landing to the top of multi- line text. 3. Dimensions should be associative. Note: The AutoCAD DIMASSOC system variable is not stored in a dimension style. 4. The following table can be used as a general guide for dimension settings. Dimension distance values are in plotted inches. FIGURE DIMENSION SETTINGS DIMENSION SETTING SYSTEM VARIABLE VALUE FOR PROPOSED VALUE FOR EXISTING Associative Dimensions DIMASSO 2 2" Extension line beyond dimension line DIMEXE 0.05" 0.05" Extension line offset from object DIMEXO 0.05" 0.05" Arrow Size DIMASZ 0.10" 0.08" Dimension Text Style DIMTXSTY ARIAL ARIAL Dimension Text Height DIMTXT 0.07" 0.05" Dimension Primary Units DIMLUNIT 2 (Decimal) 2 (Decimal) Dimension Precision DIMDEC

13 3.4 LINE WEIGHTS 1. The HCFCD.CTB plot configuration file included with the project package specifies plotted line weights. No modifications are to be made to this file. 2. Show existing objects, existing text and dimensions unscreened (100%) color 8 (gray) as set up in the.ctb file. 3. Show hatch objects unscreened (100%) color 252 (gray) as set up in the.ctb file. 4. Show proposed objects, text and dimensions unscreened (100%) as set up in the.ctb file. 5. The following table is based on the National CAD Standard V5, 2.0 line width guide. FIGURE LINE WEIGHTS THICKNESS MM IN. TYPICAL USE EXTRA FINE Hatch patterns, table and section grid lines, and sheet trim lines, existing object lines and text FINE Proposed fine object lines THIN Proposed text, proposed thin object lines MEDIUM Proposed medium object lines WIDE Sheet and title block borders, sheet dividers, major title underlines, outlines, location map outlines, section lines, proposed object lines requiring special emphasis EXTRA WIDE ROW XX WIDE

14 3.5 LINETYPES 1. Use Figure 3.5 Linetypes as a general guide for all linetypes. The line weights shown in Figure 3.5 are shown as a general rule. It is understood that there may be times when objects will need to be shown in a different line weight for clarity or emphasis. In addition, it is expected that standard drafting practices be used to determine proper spacing and distance between lines for legibility purposes. 2. Set linetype scale value to 1.0 paperspace scale such that all linetypes may be easily identified at plotted scales. 14

15 HCFCD CAD Standards Manual!"#$ 15

16 3.6 SYMBOLS AND HATCH PATTERNS 1. Use Figure Symbols, Labels and Hatch Patterns as a general guide for symbols, labels, and hatch patterns. 2. Hatch patterns shall be associative. AutoCAD system variable HPASSOC = Create hatch patterns with a boundary. AutoCAD system variable HPBOUNDRETAIN = Set hatch pattern scale values such that all patterns may be easily identified at plotted scales. FIGURE SYMBOLS, LABELS AND HATCH PATTERNS GENERAL TOPO FEATURE LINE WEIGHT (IN.) EXIST. PROP. SYMBOL/PATTERN EXIST. SLOPE SYMBOLS NA PROP. SLOPE SYMBOLS NA FLOW ARROW NA NA SLOPE LABELS RIPRAP OUTLINE HATCH CHANNEL SHELF OUTLINE HATCH CONCRETE LINING OUTLINE HATCH

17 FIGURE SYMBOLS, LABELS AND HATCH PATTERNS FEATURE LINE WEIGHT (IN.) EXIST. PROP. SYMBOL/PATTERN TREE LINE WETLANDS OUTLINE HATCH WATER SURFACE ELEVATION STRUCTURES BUILDING EXISTING INLETS NA PROPOSED INLETS NA STORM/SANITARY MANHOLES OTHER MANHOLES SURVEY EXISTING ELEVATION NA PROPOSED ELEVATION NA IRON ROD MONUMENTS POINT OF CURVATURE (PT) or POINT OF TANGENCY (PT)

18 FIGURE SYMBOLS, LABELS AND HATCH PATTERNS FEATURE POINT OF INTERSECTION (PI) LINE WEIGHT (IN.) EXIST. PROP SYMBOL/PATTERN SWPPP (SEE SWPPP DETAIL SHEET) GENERAL DRAFTING SECTION MARKERS NA SECTION LABELS NA DETAIL MARKER NA DETAIL LABEL NA GRAPHICAL SCALE NA

19 3.7 DRAWING SCALES 1. Graphical drawing scales are required on all scaled drawings. Scales will vary depending on the type and size of project and the amount of information required. 2. Plans and profiles shall be prepared on single bank plan/profile sheets and drawn using appropriate horizontal and vertical scales. 3. Preferred standard scales for plan and profile on construction drawings are as follows: FIGURE DRAWING SCALES CHANNEL CHANNEL ROW < 120' OR CHANNEL DEPTH < 12' CHANNEL ROW > 120' OR CHANNEL DEPTH > 12' DETENTION BASINS SCALES HORIZONTAL: 1"=40'; 1"=50' VERTICAL: 1"=4'; 1"=5' HORIZONTAL: 1"=80'; 1"=100' VERTICAL: 1"=8'; 1"=10' DEPENDANT UPON BASIN SIZE (MUST BE APPROVED BY HCFCD PROJECT MANAGER PRIOR TO USE) 4. Details of special structures shall be drawn with equal vertical and horizontal scales unless otherwise approved by HCFCD Project Manager. 5. Additional scales may be allowed with HCFCD Project Manager approval. 3.8 STATIONING 1. Although centerline stationing is preferred, baseline stationing may be used for projects that are confined to small areas (i.e. bridges, repair of structures, etc.). The bottom of the sheet will be labeled, so as to indicate which method of stationing was utilized. 2. Stationing shall proceed from downstream to upstream, and run from left to right on the plan sheet. 3. Tic symbols shall be used to mark stations. 19

20 3.9 DRAWING ORIENTATION 1. The North arrow shall be oriented subject to item 3.9 stationing. It is preferred that the project site shall be oriented such that the North arrow is oriented toward the top, or to the right, of the sheet MATCH LINES 1. Match lines shall be located at each end of plan view, perpendicular to the design centerline and shall be labeled as to station, and matching sheet number. 2. Match lines should be placed at even stations where practicable. 3. Do not place match lines in channel intersections or in the middle of pertinent structures CONTENT - PLAN VIEW The following information should be displayed in the drawing plan view: 1. The plan view shall be prepared in model space to scale and on coordinates. The plan will be presented in paper space through a viewport window to an appropriate scale. 2. A graphical scale and north arrow are required on all scaled drawings. 3. All topographic features visible on the ground at the time of the survey within the existing and/or proposed ROW including all structures and/or improvements outside, but within thirty (30) feet of, the proposed ROW unless otherwise directed by the project manager per HCFCD PCPM & HCFCD Survey Guidelines. 4. The design centerline and/or baseline with stationing. Multiple centerlines (or baselines) should be clearly designated CL "A", BL "B", etc. and labels shall include reference to the related CL or BL. Example: CL A STA or BL "B" STA Existing and Proposed ROW lines. 6. Existing road and utility ROW and easement lines that intersect, abut, cross, or run adjacent to the project ROW. 7. Lot lines and property lines that intersect the project ROW. 20

21 8. Legal property information and street addresses shall be provided for all property adjacent to channel ROW unless otherwise approved by the Project Manager. 9. Top of slope, toe of slope, centerline, and direction of flow for all proposed and existing channels. 10. Proposed and existing slope symbols (minimum 2 sets of 3 per bank, per sheet). 11. All known utilities including their size, depth, product, and owner. 12. Provide owner and contact information for all pipeline companies. 13. Roadway surface where roadways are within or cross the existing and/or proposed ROW. 14. Existing and proposed outfall pipes and structural features within existing and proposed channels. 15. Existing and proposed back slope swales, structures, summits, shall be shown, but without station or elevation. 16. Proposed structures shall be labeled with reference to the detail callout and sheet number. 17. Stations of all Path Inflections, Path Curvatures, and Path Tangents on the design centerline. 18. All other visible or underground features pertinent to the project that may not be specified above. 19. Existing offsite swales and ditches with direction of flow CONTENT - PROFILE VIEW The following information should be displayed in the drawing profile view: 1. Profiles shall be prepared on a grid in model space and drawn using an appropriate horizontal and vertical scale as provided in Section 3.7 DRAWING SCALES. The profile will be presented in paper space through a viewport window to an appropriate scale. 2. Profile of left and right natural ground at the ROW for all channels. Identify as East ROW, North ROW, etc. 21

22 3. Centerline flowline profile of existing and proposed channels. 4. Include existing and proposed inlets and outfalls at their confluence with the channel or basin. 5. Proposed outfall elevations shall be labeled only if design specific, otherwise the structure will be drawn and constructed as per HCFCD standard detail. 6. Proposed inlets and their outfalls shall be profiled separately from channel or basin profiles. 7. Profile of all existing and proposed structures within the ROW and their elevation. 8. All utility lines crossing or parallel to the construction. 9. Proposed centerline elevations at the beginning and end of the project, at match line stations, at grade breaks and at channel configuration changes. 10. Design grades and channel design (i.e. 20' bottom and 4:1 side slopes, s = 0.05%) shall be indicated on each sheet for proposed channel improvements. 11. All other pertinent features of the project not specified above. 12. Top elevation (or distance from flowline) for erosion protection (concrete lining and riprap) CONTENT - CROSS SECTIONS 1. Channel cross sections and typical sections representing large drainage structures (i.e. detention basins, weirs, bridges, etc.) shall be prepared on a grid in model space and drawn using an appropriate horizontal and vertical scale. Cross sections shall be typically drawn with horizontal and vertical scales of 1 = 10. Optional scales of 1 = 20 or 1 = 5 may be required on some projects. Distorted horizontal and vertical scales are not acceptable unless approved by the HCFCD project manager. 2. Cross sections shall extend 20' (min.) beyond proposed ROW or as necessary to show pertinent features. 3. Cross sections shall be typically shown at 200- foot intervals and at major channel variations, special structures, and changes in channel configuration. Consult with the Project Manager before establishing the cross- section frequency. 22

23 4. Typical Section marks in plan view shall include the section letter and the sheet number reference. Typical section letter shall not be repeated on the same plan sheet. 5. All cross sections shall be located on the grid sheets such that the centerline of the proposed channel aligns through all cross sections in each column. Sections shall run from the bottom (most downstream cross section) of the sheet to the top (moving successively upstream), and be plotted facing upstream. Include the following note on each cross section sheet: CROSS SECTIONS ARE DRAWN FACING UPSTREAM. 6. Each cross section shall identify channel station, ROW, baseline, centerline, existing natural ground, proposed channel (or basin) top of bank, toe of slope, slope breaks, existing utilities, proposed utilities, and other relevant existing and proposed features. 7. One cross section per sheet (min.) shall dimension the typical proposed bottom width and side slope, unless widths and slopes vary, then all cross sections shall be dimensioned. The ROW shall be dimensioned relative to the baseline/centerline. 8. Volumes are preferred to be generated by comparison of surfaces. Computed total cut and fill quantities shall be placed in a volume summary table on the first cross section sheet unless defined by the HCFCD project manager or other sheet as potentially required by permitting agency. If volumes are generated by comparisons of surfaces a cut and fill volume surface drawing with labels shall be provided for review. 9. Volumes may be determined by average end areas for smaller projects not using surface models. The volume table shall show the station, distance between stations, cut and fill area (square feet), cut and fill volume (cubic yards), and cumulative cut and fill volume (cubic yards) proceeding upstream. 10. Indicate on the cross section drawing the method used to calculate cut and fill quantities STRUCTURAL AND MISCELLANEOUS DETAIL SHEETS 1. Structural details shall be drawn to an appropriate equal scale vertically and horizontally. 2. All details shall include rebar size and spacing, construction joints, weep holes, toe walls, transitions, bedding, backfill and compaction requirements, dimensions, elevations, special construction notes, and all pertinent information necessary for construction. 23

24 3. Provide a typical channel section (or sections as needed). Show typical ROW, side slope, bottom width, backslope swale location, location in ROW, and berm grading. State limits applicable to the typical section (based on CL or BL Sta.). 4. Detail indicators in plan view shall include the detail number and the sheet number reference. Detail number shall not be repeated in the plan set. 4. SUBMITTAL REQUIREMENTS 4.1 SOFTWARE AND DATA FORMATS 1. Data used in the design and production process must be submitted to assist in the project review. HCFCD S preference is AutoCAD Civil 3D. However, the use of other software able to convert files into a format compatible with 3D is acceptable. Large program projects may require AutoCAD Civil 3D to ensure compatibility throughout the program. Figure 4.1 is a sample of software and data formats commonly used in the civil industries. Tools other than those listed may be used, but it will be the consultant s responsibility to translate the files into a format compatible with tools employed by the HCFCD in the review process. FIGURE SOFTWARE AND DATA FORMATS TYPE PRODUCT EXTENSION CAD AUTOCAD.DWG WORD PROCESSING MICROSOFT WORD.DOC,.DOCX SPREADSHEETS MICROSOFT EXCEL.XLS,.XLSX SCANNED IMAGES NOT APPLICABLE.TIF,.PDF SPATIAL DATA ESRI, AUTOCAD MAP.XML,.SHP DATA COMPRESSION WINZIP.ZIP MICROSTATION MICROSTATION.DGN 24

25 4.2 HARDCOPY DELIVERABLES 1. Review and final copies of construction plans to be submitted per the Consultant Agreement. See Section PDF files for sheets with electronic signatures will be produced directly from printed copies. See Section 2.4, Note 4, for plan sheet signature requirements. 3. The entire record drawing set must be delivered as a single PDF file. For best results, the PDF file should be exported directly from the drawing file, except for sheets with original hard signatures, such as the cover sheet and sheets having outside agency signatures which are scanned to PDF format. Scanning resolution shall be a minimum 600 dpi with a scan quality suitable for high quality reproduction. 4.3 ELECTRONIC DELIVERABLES 1. The entire project including electronic files is required as the final deliverable. Electronic files include all files and formats used to produce final deliverables (i.e.,.dwg,.xls,.doc, etc.). 2. Include a letter of transmittal with each submission identifying and describing the files being transferred. 3. All digital data files shall be submitted on suitable digital media (i.e. CDs, DVDs, and/or thumb drives etc.), or uploaded to the HCFCD s file share website. 4. Interim and final CAD deliverable files shall use AutoCAD Civil 3D format. These Civil 3D generated entities (points, surfaces, alignments, profiles, etc.) shall have been created in a current AutoCAD Civil 3D software version at time of submittal. Anticipated approved exceptions to this requirement may be for small 2D projects only or those already in design at the time of this Manual s release. Include all digital project data relevant to design review including, but not limited to, the following: a. Project drawing files (.DWG format) b. Externally referenced drawings and spatial data stored in the project drawing folder, or a subfolder, using the Relative Path option. c. Drawings containing relevant surfaces, TINs, contours, and points. d. Data reference files (LANDXML format) with all associated surface, alignment, and pipe network source drawings. e. External point, surface, and alignment project databases. 25

26 4.4 SURVEY DATA 1. Provide coordinate files, legal descriptions and other text- based survey data in ASCII format unless otherwise approved. 2. Coordinate files shall include point number, northing, easting, elevation, and description in comma- delimited format. 4.5 CAD SUPPORT DATA 1. Provide all non- standard or custom graphic shape files (.SHX), line type files (.LIN), font files, and drawing blocks (.DWG) necessary to properly display the design. 2. Provide the report produced using the Drawing Standards File (.DWS file included in the project package) to demonstrate compliance with HCFCD Drawing and Graphic Standards. 26

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

CHAPTER 11. Plan Standards

CHAPTER 11. Plan Standards CHAPTER 11 Plan Standards A. Introduction The city requires uniform public improvement plans for ease of record keeping and understanding. The following standards govern most plan submittals to the city.

More information

Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts

Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts PUBLIC WORKS ENGINEERING DEPARTMENT Revised: February 1, 2017 MINIMUM DRAWING REQUIREMENTS A. GENERAL PLAN REQUIREMENTS:

More information

SCHEDULE 10 ENGINEERING DRAWING SUBMISSION

SCHEDULE 10 ENGINEERING DRAWING SUBMISSION SCHEDULE 10 ENGINEERING DRAWING SUBMISSION Subdivision, Development and Servicing Bylaw No. 1535 10. ENGINEERING DRAWING SUBMISSIONS TABLE OF CONTENTS 1.0 General 3 1.1. Introduction 3 1.2. General Requirements

More information

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements

More information

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE E-10 ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS The City of Lompoc has determined that the Engineering Division should administer and issue Encroachment

More information

DIGITAL DATA SUBMISSION STANDARDS Procedures and Guidelines

DIGITAL DATA SUBMISSION STANDARDS Procedures and Guidelines DIGITAL DATA SUBMISSION STANDARDS Procedures and Guidelines 2014 Citizens Wastewater of Westfield - GIS Digital Standards Table of Contents Introduction... 3 Definitions and Terms... 3 Reference Documents...

More information

Section 101. Street Design

Section 101. Street Design Section 101 Street Design This section establishes the uniform policies and procedures for the preparation of street design plans and construction requirements in the City of Irvine. It is not intended

More information

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

1.1 GENERAL RECORD DRAWING REQUIREMENTS

1.1 GENERAL RECORD DRAWING REQUIREMENTS Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has

More information

Plan Preparation Checklist

Plan Preparation Checklist Appendix D Plan Preparation Checklist It is the responsibility of the Designer to complete and submit this checklist along with all required drawings for OUC (EFP) Review. All drawings submitted for OUC

More information

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS SECTION 3 IMPROVEMENT PLAN REQUIREMENTS CONTENTS Page 3-1 Digital Submittals 3-2 3-2 Paper Size and Scale 3-2 3-3 Drafting Standard 3-2 3-4 Title Sheet 3-2 3-5 Title Block 3-3 3-6 Drainage, Sewer, Water,

More information

PART XII: TOPOGRAPHIC SURVEYS

PART XII: TOPOGRAPHIC SURVEYS PART XII: TOPOGRAPHIC SURVEYS 12.1 Purpose and Scope The purpose of performing topographic surveys is to map a site for the depiction of man-made and natural features that are on, above, or below the surface

More information

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST YES* GENERAL SUBMISSION ITEMS Does the submission include: 1. Thirteen (13) copies of completed Application Form? 2. Thirteen (13) copies of the Preliminary

More information

Update: July 20, 2012

Update: July 20, 2012 Location and Design Manual, Volume 3 ODOT Office of CADD and Mapping Services Update: July 20, 2012 ** NOTE: All metric references have been removed from this manual. ** PREFACE REVISIONS Glossary of Terms

More information

9 LAND SURVEYING. 9.1 General. 9.2 Administrative Requirements Standards Meetings Survey Data Provided to the Design-Builder

9 LAND SURVEYING. 9.1 General. 9.2 Administrative Requirements Standards Meetings Survey Data Provided to the Design-Builder 9 LAND SURVEYING 9.1 General The Design-Builder shall conduct all Work necessary to meet the requirements associated with land surveying, including Project and supplemental horizontal and vertical control

More information

Ohio Department of Transportation, VBA Documentation

Ohio Department of Transportation, VBA Documentation Contents 1.1 Current Versions... 2 1.2 Overview... 3 1.3 Supporting Files and Standards... 4 1.3.1 ODOT_Drainage.cel... 4 1.3.2 ODOT2013.ddb... 5 1.4 ODOT_StormSewerPlan2013.mvba... 6 1.4.1 Mode: Place

More information

Grease Interceptor Design Checklist

Grease Interceptor Design Checklist CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private

More information

Sewer Line Extension Permit Design Checklist

Sewer Line Extension Permit Design Checklist CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line

More information

PRECISE GRADING PLAN CHECKLIST

PRECISE GRADING PLAN CHECKLIST PRECISE GRADING PLAN CHECKLIST PUBLIC WORKS DEPARTMENT / ENGINEERING DIVISION 8130 Allison Avenue, La Mesa, CA 91942 Phone: 619. 667.1166 Fax: 619. 667.1380 Grading plans shall address both rough grading

More information

City of Massillon Site Plan Checklist

City of Massillon Site Plan Checklist City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete

More information

Date Requested, 200_ Work Order No. Funding source Name of project Project limits: Purpose of the project

Date Requested, 200_ Work Order No. Funding source Name of project Project limits: Purpose of the project Bureau of Engineering SURVEY DIVISION REQUEST FOR TOPOGRAPHIC SURVEY Date Requested, 200_ Work Order No. Funding source Name of project Project limits: Purpose of the project Caltrans involvement (must

More information

CHAPTER 11 SURVEY CADD

CHAPTER 11 SURVEY CADD CHAPTER 11 SURVEY CADD Chapter Contents Sec. 11.01 Sec. 11.02 Sec. 11.03 Sec. 11.04 Sec. 11.05 Sec. 11.06 Sec. 11.07 Sec. 11.08 Sec. 11.09 Sec. 11.10 General Description of Survey File Contents of Survey

More information

Record Drawing Standards for Projects Version 2.1

Record Drawing Standards for Projects Version 2.1 for Projects Version 2.1 Updated September 21, 2016 Department: Spatial Data Group Engineering & Maintenance 1. INTRODUCTION... 1 2. GENERAL STANDARDS... 1 2.1 Drawing Standards... 1 2.2 Digital Submission

More information

MAJOR GRADING PLAN CHECKLIST

MAJOR GRADING PLAN CHECKLIST MAJOR GRADING PLAN CHECKLIST PUBLIC WORKS DEPARTMENT / ENGINEERING DIVISION 8130 Allison Avenue, La Mesa, CA 91942 Phone: (619) 667-1166 Fax: (619) 667-1380 Grading plans shall address both rough grading

More information

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360) CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION

More information

SECTION 9.00 AS-BUILT DRAWING REQUIREMENTS SUB-INDEX

SECTION 9.00 AS-BUILT DRAWING REQUIREMENTS SUB-INDEX SECTION 9.00 AS-BUILT DRAWING REQUIREMENTS SUB-INDEX 9.00 AS-BUILT DRAWING REQUIREMENTS 9.01 As-Built Check List 1 Supp 1 2016 Supp # 2 Aug. 2017 AS-BUILT DRAWING REQUIREMENTS As-Built Review Fee is $200.00

More information

Ecological Restoration Drafting & Design Guidelines

Ecological Restoration Drafting & Design Guidelines Ecological Restoration Drafting & Design Guidelines Version 2.0 July 2017 Philadelphia Water Ecological Restoration Drafting & Design Guidelines Table of Contents 1.0 INTRODUCTION...2 2.0 GENERAL PLAN

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND DIRECTIVE 1C-12 Issue date: August 2012 1. General SURVEY, MAPPING AND UTILITY LOCATING This Directive has been developed as a general guide for the survey and mapping effort required for Fund projects.

More information

Washington County Road Engineering Plan Submittal/Review Checklist

Washington County Road Engineering Plan Submittal/Review Checklist Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should

More information

Chapter 13 Plan Submittals

Chapter 13 Plan Submittals Chapter 13 Plan Submittals U30013.DOC 02/01/07 Chapter 13 Plan Submittals Section Topic Page 13.1 General 13.1 13.2 Subdivision Plans 13.1 13.3 Capital Improvement Project Plans 13.12 U30013.DOC 02/01/07

More information

Type A. BWSC CAD Standards for Site Plans (Design and As-Built) Format. Scale. Fonts, Linetypes, Shapes

Type A. BWSC CAD Standards for Site Plans (Design and As-Built) Format. Scale. Fonts, Linetypes, Shapes BWSC CAD Standards for Site Plans (Design and As-Built) Type A The following CAD standards are for Type A application and involve no work in Public Street, except for connection(s) to the Boston Water

More information

Section 4: Ontario Realty Corporation CAD Standards and Guidelines

Section 4: Ontario Realty Corporation CAD Standards and Guidelines Section 4: Ontario Realty Corporation CAD Standards and Guidelines Ontario Realty Corporation 11 th Floor, Ferguson Block 77 Wellesley Street West Queen s Park Toronto, ON, M7A 2G3 August 10, 2007 Version

More information

Miami University. Physical Facilities Department. CAD Standards. April 2004

Miami University. Physical Facilities Department. CAD Standards. April 2004 Miami University Physical Facilities Department CAD Standards April 2004 1.0.0 OVERVIEW These standards pertain to the use, production and submittal of electronic CAD files at Miami University. They have

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of

More information

DEVELOPMENT PLAN CHECKLIST

DEVELOPMENT PLAN CHECKLIST Project Identification Information: DEVELOPMENT PLAN CHECKLIST 1.0 GENERAL 1.1 Additional information as required by specific Land Use 1.2 All sheets to include sheet number ( of ) 1.3 Seal and signature

More information

URBAN DRAINAGE AND FLOOD CONTROL DISTRICT

URBAN DRAINAGE AND FLOOD CONTROL DISTRICT URBAN DRAINAGE AND FLOOD CONTROL DISTRICT Digital Flood Hazard Area Delineation (DFHAD) Guidelines July 2009 Prepared by 720 South Colorado Boulevard Suite 410 S Denver, Colorado 80246 phone (303) 757-3655

More information

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under

More information

PRELIMINARY PLAT CHECK LIST

PRELIMINARY PLAT CHECK LIST Name of Proposed Subdivision: The following items must be included with the initial submittal of a Preliminary Plat: Application, filled out completely Project Narrative Pre-application Conference Report

More information

PART XIII: HYDRAULIC/ HYDROLOGY SURVEYS

PART XIII: HYDRAULIC/ HYDROLOGY SURVEYS PART XIII: HYDRAULIC/ HYDROLOGY SURVEYS 13.1 Purpose and Scope Hydraulic surveys are required for flow analysis to determine bridge and culvert design characteristics. A hydraulic survey is usually but

More information

CHAPTER A-10 DRAWINGS

CHAPTER A-10 DRAWINGS CHAPTER A-10 DRAWINGS INDEX Revised May 2018 10.1 GENERAL 10.1.1 Purpose and Scope 10.2 APPLICABLE PUBLICATIONS 10.3 COMPUTER AIDED DESIGN (CAD) 10.3.1 CAD Requirements 10.3.2 CAD Deliverables 10.3.3 CAD

More information

SECTION SITE SURVEYS

SECTION SITE SURVEYS SECTION 02 21 13 SITE SURVEYS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section to specify survey required before design

More information

WATER WASTEWATER CAD DELIVERABLES SUBMISSION STANDARDS

WATER WASTEWATER CAD DELIVERABLES SUBMISSION STANDARDS WATER WASTEWATER CAD DELIVERABLES SUBMISSION STANDARDS New Braunfels, TX 78130 Approved November 15, 2004 PREFACE In order to create a consistency and increase efficiency, Comal County, Comal Appraisal

More information

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.

More information

DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS

DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS CITY OF ALBANY DEPARTMENT OF PUBLIC WORKS DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS Prepared By PUBLIC WORKS DEPARTMENT ALBANY, OREGON 97321 Telephone: (541) 917-7676 TABLE OF CONTENTS A 1.00

More information

SECTION 6A ROADWAY PLAN PREPARATION

SECTION 6A ROADWAY PLAN PREPARATION SECTION 6A ROADWAY PLAN PREPARATION Table of Contents Page No 6A.1 GENERAL...1 6A.2 PRELIMINARY PLANS...3 6A.2.1 PRELIMINARY PLAN SHEETS...3 6A.2.2 PRELIMINARY PROFILE SHEETS...4 6A.3 PHASE A PLANS...4

More information

BASIC CADD DRAWING PROCEDURES

BASIC CADD DRAWING PROCEDURES BASIC CADD DRAWING PROCEDURES I. Set up Electronic Drawing Environment: 1) SET UNITS 2) DETERMINE ELECTRONIC SCALE FACTOR (SF) a. CALCULATE WHITE SPACE 3) SET LIMITS (MODEL SPACE) 4) ZOOM ALL, F7 (TURN

More information

CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS

CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS 11.01.00 Preliminary Site Plan Approval 11.01.01 Intent and Purpose 11.01.02 Review 11.01.03 Application 11.01.04 Development Site to be Unified 11.01.05

More information

Minor Site Plan Application and Checklist Land Disturbing Activities

Minor Site Plan Application and Checklist Land Disturbing Activities Minor Site Plan Application and Checklist Land Disturbing Activities INSTRUCTIONS: Please provide the requested information below. The Development Services Department reviews each site plan submittal based

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for

More information

3. The PAC (Permit Application Center) will notify the design professional of plan review results.

3. The PAC (Permit Application Center) will notify the design professional of plan review results. Planning and Development Dept. Infrastructure Division P.O. Box 11706, or 155 Johnston Street Rock Hill, South Carolina 29731-1706 Phone: 803-329-5515 FAX: 803-329-7228 www.cityofrockhill.com AS-BUILT

More information

Town of Westlake Construction Plans Review Checklist

Town of Westlake Construction Plans Review Checklist CONSTRUCTION PLANS CONTENTS All Drawings 24 x 36 Cover Sheet Final Plat Site Plan Demolition Plan Utility Plan Drainage Area Map and Calculations Paving Plan & Profile Sheets Storm Drain Plan & Profile

More information

List of Figures. List of Forms

List of Figures. List of Forms City of Columbia Engineering Regulations PART 1: SUBMISSION OF PLANS Table of Contents Paragraph Description Page No. 1.1 General 1-1 1.2 Engineer s Report 1-1 1.3 Plans 1-3 1.4 Revisions to Approved Plan

More information

CHAPTER 3 INFORMATION REQUIRED FOR PUBLIC IMPROVEMENT CONSTRUCTION PLANS TABLE OF CONTENTS

CHAPTER 3 INFORMATION REQUIRED FOR PUBLIC IMPROVEMENT CONSTRUCTION PLANS TABLE OF CONTENTS CHAPTER 3 INFORMATION REQUIRED FOR PUBLIC IMPROVEMENT CONSTRUCTION PLANS TABLE OF CONTENTS Section Title Page 3.1 General... 3-1 3.1.1 Plan Set...3-1 A. Loveland (City Limits Only)...3-1 3.1.2 Final Mylars...3-1

More information

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges 50.24 Culverts, Bridges and Culvert Bridges Type, Size and Location (T, S & L) Plans shall be required for all Bridges, Culvert Bridges and Culverts of eight-foot (8') clear span or greater as follows:

More information

CONSULTANT: Wantman Group, Inc SERVICE AUTHORIZATION NO. _12-03 FOR CONSULTING SERVICES CITY PROJECT NO CONSULTANT PROJECT NO.

CONSULTANT: Wantman Group, Inc SERVICE AUTHORIZATION NO. _12-03 FOR CONSULTING SERVICES CITY PROJECT NO CONSULTANT PROJECT NO. EXHIBIT A CONSULTING SERVICE AUTHORIZATION DATE: CONSULTANT: Wantman Group, Inc SERVICE AUTHORIZATION NO. _12-03 FOR CONSULTING SERVICES CITY P.O. NO. CITY EXPENSE CODE CITY PROJECT NO. 14-073 CONSULTANT

More information

CAD STANDARDS & DRAWING RECORD REQUIREMENTS

CAD STANDARDS & DRAWING RECORD REQUIREMENTS CAD STANDARDS & DRAWING RECORD REQUIREMENTS Version 3.0 City of Coquitlam * Engineering & Public Works * September 2016 3000 Guildford Way, Coquitlam, British Columbia V3B 7N2 File #: 11-5220-02/000/2

More information

Oil-Water Separator Design Checklist

Oil-Water Separator Design Checklist CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water

More information

Issue Date: August 2018 Revision: 03

Issue Date: August 2018 Revision: 03 ENGINEERING CADD MANUAL Issue Date: August 2018 Revision: 03 Developed For: Metra Engineering Department 547 West Jackson Blvd. Chicago, Illinois 60661 Developed By: Chandra Mahalingam CADD System Administrator

More information

Engineering Department DRAWING STANDARD SPECIFICATIONS

Engineering Department DRAWING STANDARD SPECIFICATIONS DRAWING STANDARD SPECIFICATIONS June 2017 City of Surrey TABLE of CONTENTS Page i Page 1 INTRODUCTION... 1 1.1 Overview... 1 1.2 Measurements / Units... 1 1.3 Hardcopy and Digital Template... 1 2 DRAWING

More information

3. DESIGN SPECIFICATIONS

3. DESIGN SPECIFICATIONS Schedule H to Bylaw 7452, Subdivision Bylaw Page 10 3. DESIGN SPECIFICATIONS 3.1 General 3.1.1 The Design Specifications apply to the design of sanitary sewers, storm drains, waterworks, roadways, and

More information

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS Public Works Department Water & Wastewater Services WATER & WASTEWATER ENGINEERING DIVISION 2555 West Copans Road Pompano Beach, Florida 33369 954-831-0745 FAX 954-831-0798/0925 MINIMUM DRAWING REQUIREMENTS

More information

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS SECTION 2.1 INTRODUCTION... 1 (a) Objective...1 (b) Applicability...1 2.2 SUBMITTAL

More information

APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST

APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST VI-K -1 of 8 APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST Final Submittal Major Subdivision Project Name Subdivision Number Location (Street

More information

The coordinate system and vertical datum shall be noted in the drawing in the metadata.

The coordinate system and vertical datum shall be noted in the drawing in the metadata. Purpose This document is provided for informational purposes and to assure data compatibility and compliance for as-built drawings or vector data formats specifically for the 354th Civil Engineer Squadron

More information

Clarifications in italics added July 2018

Clarifications in italics added July 2018 SECTION 10000 RECORD DRAWING CHECKLIST Clarifications in italics added July 2018 All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes,

More information

DOCUMENT MINIMUM CONSTRUCTION DRAWING REQUIREMENTS FOR PRELIMINARY REVIEW/APPROVAL 1.2. GALVESTON COUNTY CONSOLIDATED DRAINAGE DISTRICT (GCCDD)

DOCUMENT MINIMUM CONSTRUCTION DRAWING REQUIREMENTS FOR PRELIMINARY REVIEW/APPROVAL 1.2. GALVESTON COUNTY CONSOLIDATED DRAINAGE DISTRICT (GCCDD) DOCUMENT 01105 FOR PRELIMINARY REVIEW/APPROVAL PART I: SUBMITTAL 1.1 CITY OF FRIENDSWOOD (COF) A. Submit four (4) copies of drawings. B. Submit by 5:00 PM a minimum of fourteen calendar days (14 cd) prior

More information

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing

More information

CONCEPT REVIEW GUIDELINES

CONCEPT REVIEW GUIDELINES Department of Planning & Community Development @ Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344 404.270.7212 (Phone) 404.765.2784 (Fax) www.eastpointcity.org CONCEPT REVIEW GUIDELINES

More information

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS Detailed construction drawings for system extensions shall be prepared for approval with a submittal to the Authority. All construction

More information

Council Policy Engineering Drawing Submission Requirements

Council Policy Engineering Drawing Submission Requirements POLICY 265 City of Kelowna 1435 Water Street Kelowna, BC V1Y 1J4 250 469-8500 kelowna.ca Council Policy Engineering Drawing Submission Requirements APPROVED June 4, 2001 RESOLUTION: R375/10/04/26 REPLACING:

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 29, 2012

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 29, 2012 SECTION 01950 - RECORD DRAWINGS & SPACE FLOOR PLANS 1.1 RECORD DRAWINGS MATERIAL AND FORMAT A. Definition 1. Final record drawings, or as-builts, are drawings, which are revised to reflect the changes

More information

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee) MEMORANDUM MICHAEL B. FLETCHER, P.E. COUNTY ENGINEER 327 N. Ashley Street Valdosta, GA 31601 Telephone: (229) 671-2424 Fax: (229) 245-5299 mfletcher@lowndescounty.com LOWNDES COUNTY ENGINEERING PLAN REVIEW

More information

PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS. Date: January 26, 2001

PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS. Date: January 26, 2001 PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS Date: January 26, 2001 Portage County Water Resources Drafting Standards. AutoCad 2000/Land Development Desktop R2 Friday, January 26, 2001 Preface: Part

More information

Survey Data and TOPO Checklist

Survey Data and TOPO Checklist Checklists Survey Data and TOPO Preliminary Plan Field Review Plans o Field Review Erosion Control Right-of-Way and Utility Meeting Plans Final Plan Field Review Plans Methods of Plan Markups Plan-in-Hand

More information

MINOR SUBDIVISION. [ ] [ ] [ ] [ ] B. Dimensions, bearings and curve data for all property lines and easements.

MINOR SUBDIVISION. [ ] [ ] [ ] [ ] B. Dimensions, bearings and curve data for all property lines and easements. MINOR SUBDIVISION 190-69. Minor subdivisions. In addition to the requirements indicated in 190-67 (SEE BELOW), the information below shall be shown on the plans for all minor subdivision applications.

More information

Project Name: County File No.: Checked by: For: Date:

Project Name: County File No.: Checked by: For: Date: Project Name: County File No.: Checked by: For: Date: Print name Firm or agency Items noted in the checklist shall be considered the minimum amount of information necessary for submission of construction

More information

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN N/A Waiver (1) Four (4) copies of application form. (2) Fifteen (15) copies of plan (3) Subdivision/site plan application fee & professional review escrow deposit (4) Variance application fee & professional

More information

Florida's Turnpike Enterprise Roadway Phase III (90%) & Phase IV (100%) Check List Per FDM and TDH Part 3

Florida's Turnpike Enterprise Roadway Phase III (90%) & Phase IV (100%) Check List Per FDM and TDH Part 3 Notes to Reviewers Section 301 Design Exceptions, Variation, and Technical Memorandums Special directives date and source Key Sheet Section 302 Location Map w/ location of project on map All applicable

More information

8.1 Control. 8.2 Sheet Setup

8.1 Control. 8.2 Sheet Setup 8.1 Control Responsibility for development of the pipe data sheets is in the hands of the project s drainage or roadway designer. Pipe data sheets should be developed after the drainage design is fairly

More information

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS All plans for sanitary sewer main extensions, improvements and modifications

More information

SUBMITTAL REQUIREMENTS RCV D REJECT PENDING

SUBMITTAL REQUIREMENTS RCV D REJECT PENDING 1 of 5 SUBMITTAL REQUIREMENTS RCV D REJECT PENDING 1. General Information. 1.1 Applicant s name, address and contact numbers. 1.2 Project name, type, address and legal description of the property. 1.3

More information

Appendix E-4. City of Fort Collins. Requirements for Utility Plans

Appendix E-4. City of Fort Collins. Requirements for Utility Plans Appendix E-4 City of Fort Collins Requirements for Utility Plans Project Name: Project Planner: Design Engineering Firm: Developer: All applications for final development plans must include final development

More information

Subdivision Application Checklist

Subdivision Application Checklist City of Portsmouth, New Hampshire Subdivision Application Checklist This subdivision application checklist is a tool designed to assist the applicant in the planning process and for preparing the application

More information

TABLE OF CONTENTS 1200 PLAN PREPARATION

TABLE OF CONTENTS 1200 PLAN PREPARATION 1200 PLAN PREPARATION TABLE OF CONTENTS PAGE 1201 General Plan Sheet Information... 12-1 1201.1 Introduction... 12-1 1201.2 Unit of Measure... 12-1 1201.3 Plan Sheet Materials and File Format... 12-1 1201.4

More information

Stanford University-Facilities Design Guideline SECTION Plans Review Submission Guidelines

Stanford University-Facilities Design Guideline SECTION Plans Review Submission Guidelines SECTION 01 33 00 Plans Review Submission Guidelines PART 1 GENERAL 1.01 OVERVIEW A. University Plans Review Process: 1. The process by which the Designer s schematic, design development, construction documents

More information

Charlotte County Utilities DESCRIPTION

Charlotte County Utilities DESCRIPTION As-built Drawings / Surveyor 1. Electronic copy of survey data in tabular form of the utility assets 2. A signed and sealed letter with the following statement: "I hereby certify that the as-built location

More information

Authorized Agent: City of Manassas Check List Attached: Contact: Address: Phone Number: Fax Number: Developer s Name: Phone Number:

Authorized Agent: City of Manassas Check List Attached: Contact:   Address: Phone Number: Fax Number: Developer s Name: Phone Number: CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street Room 201 Manassas, Virginia, 20110 Phone: 703-257-8278 Fax: 703-257-5831 Application Date: APPLICANT

More information

Grading, Erosion and Sediment Control (GESC) Checklist

Grading, Erosion and Sediment Control (GESC) Checklist Development Services Department 100 N. Wilcox Street, Castle Rock CO 80104 Planner of the Day 303-660-1393 Grading, Erosion and Sediment Control (GESC) Checklist A complete Grading, Erosion and Sediment

More information

P.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint)

P.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint) P.L., CHAPTER, approved October, Assembly, No. 0 (First Reprint) 0 0 0 AN ACT concerning the approval and filing of maps and amending P.L.0, c.. BE IT ENACTED by the Senate and General Assembly of the

More information

Site Plan/Building Permit Review

Site Plan/Building Permit Review Part 6 Site Plan/Building Permit Review 1.6.01 When Site Plan Review Applies 1.6.02 Optional Pre- Application Site Plan/Building Permit Review (hereafter referred to as Site Plan Review) shall be required

More information

AutoCAD Civil 3D 2013 South African Country Kit

AutoCAD Civil 3D 2013 South African Country Kit AutoCAD Civil 3D 2013 South African Country Kit Contents 1 General... 3 1.1 Introduction from the author and creator... 3 1.2 Overview... 4 2 Drawing Settings... 8 2.1 Edit Drawing Settings... 8 3 Layers...

More information

AutoCAD Standards University of California, Santa Cruz Physical Planning & Construction

AutoCAD Standards University of California, Santa Cruz Physical Planning & Construction University of California, Santa Cruz Physical Planning & Construction 1. General Requirements: 1.1 Format 1.2 Ownership 2. Required Data: 2.1 Area Tabulation 2.2 Drawing Files 2.3 External References 2.4

More information

City of Kitchener Infrastructure Services Department Engineering Services Division. CAD Standards for Engineering

City of Kitchener Infrastructure Services Department Engineering Services Division. CAD Standards for Engineering City of Kitchener Infrastructure Services Department Engineering Services Division CAD Standards for Engineering Printed: October 29, 2012 Revision History Revision Description Date Layer revisions. June

More information

PLANNING AND DEVELOPMENT

PLANNING AND DEVELOPMENT OVERVIEW Effective January 1, 1992 all applications for multi-family residential and all non-residential building permits require site plan approval before permit issuance. All new developments and existing

More information

APPLICATION FOR SITE PREPARATION PERMIT

APPLICATION FOR SITE PREPARATION PERMIT Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision/Plat Name: Location Description/ Nearest Intersection: Acreage: APPLICATION FOR SITE PREPARATION PERMIT No.

More information

SECTION 2.0 PREPARATION OF MASTER PLANS, CONSTRUCTION PLANS, AND RECORD DRAWINGS

SECTION 2.0 PREPARATION OF MASTER PLANS, CONSTRUCTION PLANS, AND RECORD DRAWINGS SECTION 2.0 PREPARATION OF MASTER PLANS, CONSTRUCTION PLANS, AND RECORD DRAWINGS 2.1 MASTER PLAN 2.1.1 A Master Plan for water, wastewater, and/or reclaimed water is required for all residential or commercial

More information