1 CMS NCS CALIBRATED MATCHING STANDARDS 1950 ORIGINAL
2 CALIBRATED MATCHING STANDARDS The NCS Calibrated Matching Standards (CMS) are intended to meet the highest quality demands from professional NCS users. It is specially developed to allow colour matching and control with the smallest available tolerances. It is well suited for quality control work based on ISO 9001 standards. Each sample is individually checked against the unique NCS Primary Standard. The small reproduction differences allowed are stated for each sample. The NCS Calibrated Matching Standard samples should be stored dark, at a temperature of maximum C and in humidity between %. The colour samples will then be valid for two years from controlling date.
3 MEASUREMENT VALUES The measurement values are delivered with the NCS Calibrated Matching Standards 1950 Original on a CD or as a separate document. No: The sample/box number of the colour sample. Together with the NCS notation this number creates a unique identification for each and every NCS CMS sample measured. Date: Date of measurement, the colour sample is valid two years from this date. NCS: The NCS Colour Notation (nominal value). S C Φ: Colour co-ordinates. The s, c and Φ values calculated from measurement according to SS with one decimal. S = Blackness, C= Chromaticness and Φ = Hue. CIELAB: Co-ordinates and differences. CIELAB (L*, a*, b*, C* and h) co-ordinates are calculated for CIE Standard Daylight (D65) according to CIE publ. 15:2004. The CIE 10 degree standard observer is used. ΔL*, ΔC* and ΔH* is the difference between the CIELAB coordinates of the sample and the NCS Primary Standard. ΔE CMC(1:1) values are calculated according to CMC(1:1) in accordance with BS 6923:1988.
4 SPECIFICATION FOR CMS Max. deviations: In final production ΔE CMC(1:1) < 0.5 from NCS Primary Standard. 95% ΔE CMC(1:1) < 0.5 in F11 and in A Gloss: (small deviations might occur) Max Failure Rate: 0 % NCS Colour guarantees that in addition to these tolerances visual inspections are performed to check the production in order to avoid problems coming from the limitations of instrumental measurements. If an NCS Primary Standard is close to the NCS nominal tolerance border, and the checked NCS Calibrated Matching Standard might fall just outside the primary NCS tolerance area NCS Colour will make a visual inspection before approval. MEASUREMENT CONDITIONS FOR INSTRU- MENTAL CONTROL OF NCS SAMPLES Measurement Conditions for Instrumental Control of NCS Samples The colour measurements and analyses have been carefully made, checked and certified by the authorized NCS Quality Centre according to the Swedish Standard SS in a spectrophotometer. The conditions for visual assessment and instrumental measurement of the colour samples are made according to SS Measurement values are evaluated according to CIE (publ. 15:2004). Measurement geometry: diffuse illumination, specular component included (di:8 ). UV component included. Readings every 10 nm from 360 to 750 nm. NCS S 0500-N (white) is used as a sample backing in reflectance measurement. Measurement is traceable to the NCS reference instrument, Zeiss DMC 26. The gloss measurements are made in accordance with ISO 2813, 60. The ΔECMC (1:1) are evaluated according to BS 6923:1988. Light sources used in the control are D65, A and F11. Visual controls are made in the same light sources.
5 NCS QUALITY MANAGEMENT - SPEC. To ensure a high quality and problem-free colour communication process, NCS Colour in Stockholm set up the NCS Quality Centre, which guarantees and documents its work in order to provide accurate colour products to meet various professional needs. NCS Quality Management has world leading quality and ensures that the NCS samples are produced with EU-approved pigments and according to the NCS Primary Standard. NCS Quality Management forms the base for the Swedish, Norwegian, Spanish and South African National Standards. It is also the platform for our ISO 9001, No , Quality Assurance System. REPRODUCTION TOLERANCES The following specification for reproduction tolerances guarantees that no visually unacceptable differences should exist in the reproduction of the NCS Colour Tools. The visual checks in the production control can override the measurement result. NCS REPRODUCTION TOLERANCES* NCS Quality Level ΔE Fraction ΔE Fraction ΔE Fraction NCS CMS % NCS QL % % NCS QL % % % * Against the Primary Standard in ΔE CMC (1:1) units
6 NCS QUALITY QUALITY CATEGORIES QUALITY CONTROL PRODUCTS STANDARD NCS PRIMARY STD Produced to fall within the NCS nominal tolerance areas. NCS Colour s unique Primary standard used by NCS Colour to control reproduction of all NCS Colour Samples. For reproduction of NCS Colour tools. NCS CALIBRATED MATCHING STD Individually controlled samples with actual differences specified for each sample. A6 Colour standards. Delivered in a complete box with 1950 samples or as separate samples. Reference for accurate colour matching and quality control. NCS QUALITY LEVEL I (QL 1) Statistic control on samples from the production. Album, Block, Box, Atlas, A4, A6 and A9 colour sheets. Professional colour specification and communication. NCS QUALITY LEVEL II (QL 2) Statistic control on samples from the production. Stripe coated material used in Index, Cascade, fan decks and colour ships/stripe cards. System overview for colour selection.
7 DEFINITIONS NCS Nominal Value The theoretical value, established by the perceptive (psychometrical) NCS Colour Research. The values are scientifically and colorimetrically specified in the CIE standard system by the NCS conversion software, based on the NCS original reference instrument Zeiss DMC 26. NCS Primary Standard NCS Colour s unique deepfrozen original standard and measurement values representing (with tolerances as specified below) the NCS Nominal Values. NCS Calibrated Matching Standards Colour Standard that customers can purchase from NCS Colour representing (with tolerances as specified in this document) the NCS Primary Standard. NCS Colour Tools Commercial colour products produced by NCS Colour representing (with tolerances as specified in this document) the NCS Primary Standard.
8 NCS COLOUR AB P.O. Box 49022, SE Stockholm, Sweden +46 (0) ncscolour.com Copyright Stockholm 2015
spectro-guide Total Appearance Control color and gloss in one unit Easy to use and handle Solid Color
spectro-guide Total Appearance Control color and gloss in one unit The overall appearance of a product is influenced by color and gloss. A sample of the same color but higher gloss level is visually perceived
More informationSpectroEye. Spectrophotometer/Densitometer. The simplest and most accurate method for measuring color and density.
SpectroEye Spectrophotometer/Densitometer The simplest and most accurate method for measuring color and density. Simple. Quick. Reliable. SpectroEye combines the ultimate in measurement accuracy with exceptional
More informationProblems in Color Proofing from the Colorimetric Point of View
Problems in Color Proofing from the Colorimetric Point of View Shinji YAMAMOTO* *R&D Division, Konica Minolta Sensing, Inc. -9, Daisennishimachi, Sakai-ku, Sakai-shi, Osaka, 59-855 JAPAN Originally published
More informationGuidance document: permitted color tolerances of unicolor powder coatings for architectural applications
Guidance document: permitted color tolerances of unicolor powder coatings for architectural applications Issued by the German Paint Industry Association (Verband der deutschen Lackindustrie VdL) Preface
More informationSPECIFICATIONS FOR A QUALITY LABEL FOR DECORATION OF COATED ALUMINIUM USED IN ARCHITECTURAL APPLICATIONS Edition
SPECIFICATIONS FOR A QUALITY LABEL FOR DECORATION OF COATED ALUMINIUM USED IN ARCHITECTURAL APPLICATIONS Master version ratified by the QUALIDECO Committee on 27 April 2017 Effective from 1 July 2017 Published
More informationWhen color changes are evaluated by the human eye, all kinds of factors will affect the color perception:
Color analysis of heat yellowing and light fastness tests on leather The SmiTool Light and Heat already discussed the subject of heat yellowing and light fastness tests on leather. The current SmiTool
More informationLindab Colour Chart. Lindab Colour Chart. For every colour under the rainbow
Lindab Colour Chart For every colour under the rainbow Assortment chart Rainline and Seamline Number Name Nearest NCS Nearest RAL Rainline Standing seam roofing 001 Antique white S 1002-G50Y 9002 015 Black
More informationBYK-Gardner. Gloss and Color. Wesel, 2016, Henrik Folkerts
BYK-Gardner Gloss and Color Wesel, 2016, Henrik Folkerts Your Partner Kiel Rostock Hamburg Bremen Wesel Hannover Magdeburg Berlin Düsseldorf Erfurt Dresden Frankfurt /M. Saarbrücken Güntersthal Nürnberg
More informationThe World s Most Trusted Name In Color Quality. HunterLab
The World s Most Trusted Name In Color Quality HunterLab Introduces The ColorFlex EZ 45/0 Design: For Relentless Perfection in Color Quality The Power to See Color the Way Your Customers Do HunterLab s
More informationIEEE P1858 CPIQ Overview
IEEE P1858 CPIQ Overview Margaret Belska P1858 CPIQ Chair, CPIQ CASC Chair February 3, 2015 What is CPIQ? ¾ CPIQ = Camera Phone Image Quality Scope expanded to include all mobile cameras, not just phones
More informationThe DigiEye. System. A complete non-contact colour measurement and imaging solution.
The DigiEye There could be food and drink that cannot be measured for colour using the DigiEye System System A complete non-contact colour measurement and imaging solution. it s just that we haven t found
More informationGraphic technology Spectral measurement and colorimetric computation for graphic arts images
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 13655 Third edition 2017-07 Graphic technology Spectral measurement and colorimetric computation for graphic arts images Technologie graphique
More informationColorEye XTH. ...hand-held color accuracy on the most challenging sizes, shapes and surfaces. Spectrophotometer
ColorEye XTH Spectrophotometer...hand-held color accuracy on the most challenging sizes, shapes and surfaces. ColorEye XTH The only instrument you ll need for reading both large and small samples... as
More informationRunning head: AN ANALYSIS OF ILLUMINANT METAMERISM FOR LITHOGRAPHIC SUBSTRATES AND TONE REPRODUCTION 1
Running head: AN ANALYSIS OF ILLUMINANT METAMERISM FOR LITHOGRAPHIC SUBSTRATES AND TONE REPRODUCTION 1 An Analysis of Illuminant Metamerism for Lithographic substrates and Tone Reproduction Bruce Leigh
More informationSVENSK STANDARD SS-ISO 15994:2005. Grafisk teknik Utvärdering av glans på tryckta ytor (ISO 15994:2005, IDT)
SVENSK STANDARD Fastställd 2005-04-08 Utgåva 1 Grafisk teknik Utvärdering av glans på tryckta ytor (ISO 15994:2005, IDT) Graphic technology Testing of prints Visual lustre (ISO 15994:2005, IDT) ICS 37.100.99
More informationCIE Standards for assessing quality of light sources
CIE Standards for assessing quality of light sources J Schanda University Veszprém, Department for Image Processing and Neurocomputing, Hungary 1. Introduction CIE publishes Standards and Technical Reports
More informationColour and spectral simulation of textile samples onto paper; a feasibility study
Colour and spectral simulation of textile samples onto paper; a feasibility study Radovan Slavuj, Kristina Marijanovic, Jon Yngve Hardeberg The Norwegian Colour and Visual Computing Laboratory, Gjøvik
More informationResearch on the applicability of instrument rating test for textile color fastness
Advances in Intelligent Systems Research, volume 6 th International Conference on Sensors, Mechatronics and Automation (ICSMA 06) Research on the applicability of instrument rating test for textile color
More informationISO 13655:2009 demystified
ISO 13655:2009 demystified Why do we have M0, M1, M2 and M3? The purpose of this document is to explain in both theory and practice the measurement modes M0, M1, M2 and M3 defined in ISO 13655:2009. ISO
More informationSPECTROPHOTOMETER CM-2600d
SPECTROPHOTOMETER CM-2600d Simply expands the Boundaries in Color Control PRONOUNCING SPECTROPHOTOMETER IS THE ONLY COMPLICATED THING ABOUT OUR LATEST PRODUCT. We don t need to explain to you how important
More informationStandard Viewing Conditions
Standard Viewing Conditions IN TOUCH EVERY DAY Introduction Standardized viewing conditions are very important when discussing colour and images with multiple service providers or customers in different
More informationMetamerism, Color Inconstancy and Chromatic Adaptation for Spot Color Printing
Metamerism, Color Inconstancy and Chromatic Adaptation for Spot Color Printing Awadhoot Shendye, Paul D. Fleming III, and Alexandra Pekarovicova Center for Ink and Printability, Department of Paper Engineering,
More informationCOLOUR / GLOSS Colour
Portable Sphere Spectrophotometer The SP 60 series provides absolute and difference measurements for the following colormetric systems. These values can be obtained from any of nine illuminants with 2
More informationIMAGEMASTER : PRECISION COLOUR COMMUNICATION BASED ON CIE CALIBRATED MONITOR SCREENS
Introduction IMAGEMASTER : PRECISION COLOUR COMMUNICATION BASED ON CIE CALIBRATED MONITOR SCREENS David P. Oulton, Isaac Porat, Chris Boston, and Rob Walsby. Colour Communication Research Group, UMIST,
More informationTHE MEASUREMENT OF APPEARANCE
THE MEASUREMENT OF APPEARANCE Second Edition RICHARD S. HUNTER RICHARD W. HAROLD Hunter Associates Laboratory, Inc. Reston, Virginia A WILEY-INTERSCIENCE PUBLICATION JOHN WILEY & SONS New York / Chichester
More informationAn Analysis of Illuminant Metamerism for Lithographic Substrates and Tone Reproduction
An Analysis of Illuminant Metamerism for Lithographic Substrates and Tone Reproduction Bruce Leigh Myers, Ph.D., Rochester Institute of Technology Keywords: metamerism, color, paper Abstract Using metamerism
More informationColor Appearance, Color Order, & Other Color Systems
Color Appearance, Color Order, & Other Color Systems Mark Fairchild Rochester Institute of Technology Integrated Sciences Academy Program of Color Science / Munsell Color Science Laboratory ISCC/AIC Munsell
More informationGiving Shape to Ideas
Giving Shape to Ideas Light and Color Educational Seminars and Workshops Light and color terminologies are difficult to understand and are not main stream education curriculum. At Konica Minolta, our education
More informationISO INTERNATIONAL STANDARD. Graphic technology Colour and transparency of printing ink sets for fourcolour
INTERNATIONAL STANDARD ISO 2846-2 Second edition 2007-12-15 Graphic technology Colour and transparency of printing ink sets for fourcolour printing Part 2: Coldset offset lithographic printing Technologie
More informationA Statistical analysis of the Printing Standards Audit (PSA) press sheet database
Rochester Institute of Technology RIT Scholar Works Books 2011 A Statistical analysis of the Printing Standards Audit (PSA) press sheet database Robert Chung Ping-hsu Chen Follow this and additional works
More information#COLOR19 Ideal Viewing Conditions: QC Across the Color Supply Chain
#COLOR19 Ideal Viewing Conditions: QC Across the Color Supply Chain Robert McCurdy President GTI Graphic Technology, Inc. 1 About GTI Leading manufacturer of tight tolerance lighting systems 100% dedicated
More informationSPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control
SPECTROPHOTOMETER CM-2600d Simply expands the Boundaries in Color Control 31 PRONOUNCING SPECTROPHOTOMETER IS THE ONLY COMPLICATED THING ABOUT OUR LATEST PRODUCT. We don t need to explain to you how important
More informationPRECISE COLOR COMMUNICATION COLOR CONTROL FROM PERCEPTION TO INSTRUMENTATION
PRECISE COLOR COMMUNICATION COLOR CONTROL FROM PERCEPTION TO INSTRUMENTATION Knowing color. Knowing by color. In any environment, color attracts attention. An infinite number of colors surround us in our
More informationAnalytical Series. by Robert T. Marcus, Sun Chemical Company
Analytical Series Color and Appearance Basics for Coatings by Robert T. Marcus, Sun Chemical Company INTRODUCTION The two major functions of a coating are protection and decoration. Color and appearance
More informationConsistent Colour Appearance assessment method. CIE TC 8-16, W Craig Revie 9 th August 2017
Consistent Colour Appearance assessment method CIE TC 8-16, W Craig Revie 9 th August 2017 CIE TC8-16 Assessment of Consistent Colour Appearance Identification of resources Reference images (available
More informationA New Method for Comparing Colour Gamuts among Printing Technologies
A New Method for Comparing Colour Gamuts among Printing Technologies Esther Perales 1, Elisabet Chorro 1, Francisco Martínez-Verdú 1, Susana Otero 2, Vicente de Gracia 2 1 Department of Optics, University
More informationColor + Quality. 1. Description of Color
Color + Quality 1. Description of Color Agenda Part 1: Description of color - Sensation of color -Light sources -Standard light -Additive und subtractive colormixing -Complementary colors -Reflection and
More informationASSIGNMENT: In regard to this, Falu Rödfärg has chosen to name the other tested stains as Copy 1, Copy 2, Copy 3.
Accelerated aging in the Weatherometer (WoM) Summary of the results after 1,000 and 2,000 hours exposure in the Weatherometer Tester performed from 2015-01 to 2015-04 Falu Rödfärg engaged SP Technical
More informationBettina Selig. Centre for Image Analysis. Swedish University of Agricultural Sciences Uppsala University
2011-10-26 Bettina Selig Centre for Image Analysis Swedish University of Agricultural Sciences Uppsala University 2 Electromagnetic Radiation Illumination - Reflection - Detection The Human Eye Digital
More informationIEEE P1858 CPIQ Overview
IEEE P1858 CPIQ Overview Margaret Belska P1858 CPIQ WG Chair CPIQ CASC Chair February 15, 2016 What is CPIQ? ¾ CPIQ = Camera Phone Image Quality ¾ Image quality standards organization for mobile cameras
More informationQuality assurance. OEM Custom Services. comaroptics.com
Quality assurance OEM Custom Services comaroptics.com Our unique approach Dependable quality Whether your product ends up on Mars or in microscopes, the last thing you want is for it to fail in the hands
More informationA new algorithm for calculating perceived colour difference of images
Loughborough University Institutional Repository A new algorithm for calculating perceived colour difference of images This item was submitted to Loughborough University's Institutional Repository by the/an
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 12647-2 Third edition 2013-12-15 Graphic technology Process control for the production of halftone colour separations, proof and production prints Part 2: Offset lithographic
More informationMeter COLOR RGB Display. Measuring geometry 45 /0 - circular illumination at 45, measurement at 0. Spectral range.
Meter RGB-1002, color analyzer, R, G, B, Hue, Saturation, Luminance The RGB-1002 is a portable color meter equipped with an external sensor probe having a 45 /0 color measuring geometry. The modem, accurate
More informationQuantitative Analysis of ICC Profile Quality for Scanners
Quantitative Analysis of ICC Profile Quality for Scanners Xiaoying Rong, Paul D. Fleming, and Abhay Sharma Keywords: Color Management, ICC Profiles, Scanners, Color Measurement Abstract ICC profiling software
More informationINFLUENCE OF THE RENDERING METHODS ON DEVIATIONS IN PROOF PRINTING
30. September 2. October 2009, Senj, Croatia Technical paper INFLUENCE OF THE RENDERING METHODS ON DEVIATIONS IN PROOF PRINTING Puškarić M., Jurić N., Majnarić I. University of Zagreb, Faculty of Graphic
More informationSubstrate Correction in ISO
(Presented at the TAGA Conference, March 6-9, 2011, Pittsburgh, PA) Substrate Correction in ISO 12647-2 *Robert Chung and **Quanhui Tian Keywords: ISO 12647-2, solid, substrate, substrate-corrected aims,
More informationQuantitative Analysis of Pictorial Color Image Difference
Quantitative Analysis of Pictorial Color Image Difference Robert Chung* and Yoshikazu Shimamura** Keywords: Color, Difference, Image, Colorimetry, Test Method Abstract: The magnitude of E between two simple
More informationOkram Oy Virtasen Maalitehdas Parainen
1 / 5 Uranus Comparative Analysis Customer: Okram Oy Virtasen Maalitehdas Parainen Target: Sample 29: TM-7742, Väritiimi Petrooliöljymaali uusi C-pohja Sample 31: TM-7411, Väritiimi Petrooliöljymaali uusi
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More informationUsing modern colour difference formulae in the graphic arts
Using modern colour difference formulae in the graphic arts Funded project: Evaluating modern colour difference formulae. AiF-Nr.: 14893 N 1 Agenda 1. Graphic arts image assessment 2. Impact of the background
More informationEVALUATION OF THE CHROMATIC INDUCTION INTENSITY ON MUNKER-WHITE SAMPLES
DAAAM INTERNATIONAL SCIENTIFIC BOOK 2008 pp. 485-498 CHAPTER 41 EVALUATION OF THE CHROMATIC INDUCTION INTENSITY ON MUNKER-WHITE SAMPLES MILKOVIC, M.; MRVAC, N. & BOLANCA, S. Abstract: Systems of parallel
More informationBrillux Scala - Development of an Application-Orientated Colour System
Brillux Scala - Development of an Application-Orientated Colour System Rahe, Ulrike 1 1. Department of Product- and Production Development, Division of Design Chalmers University of Technology, SE-412
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationViewing conditions - Graphic technology and photography
Viewing conditions - Graphic technology and photography (Revision of ISO 3664-1975, Photography - Illumination conditions for viewing colour transparencies and their reproductions) i Contents Page Foreword...
More informationSVENSK STANDARD SS-ISO 3664:2004. Viewing conditions Graphic technology and photography (ISO 3664:2000, IDT) Fastställd Utgåva 1
SVENSK STANDARD Fastställd 2004-11-12 Utgåva 1 Viewing conditions Graphic technology and photography (ISO 3664:2000, IDT) ICS 37.040.01; 37.040.99; 37.100.01; 37.100.99 Språk: engelska Publicerad: december
More informationA Hybrid Model Approach for Achieving the Highest Level of Matching Between the Print and Original in the Sheet-Fed Offset Process
original scientific paper acta graphica 247 A Hybrid Model Approach for Achieving the Highest Level of Matching Between the Print and Original in the Sheet-Fed Offset Process Authors 1 Rajendrakumar Anayath*,
More informationGraphic technology Process control for the production of halftone colour separations, proof and production prints. Part 2:
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 12647-2 Third edition 2013-12-15 Graphic technology Process control for the production of halftone colour separations, proof and production prints
More informationMETHODS OF MEASUREMENT OF THE COLORIMETRIC FIDELITY OF TELEVISION CAMERAS. Measurement Procedures CONTENTS
METHODS OF MEASUREMENT OF THE COLORIMETRIC FIDELITY OF TELEVISION CAMERAS Measurement Procedures Tech 3237 E Supplement 1 Second edition - November 1989 CONTENTS Introduction... 3 CHAPTER 1 The real samples
More informationStatus quo of CIE work on. colour rendering indices
CIE Div.1/ICC/ISO Workshop on Colorimetry, Graphic Arts and Colour Management 4 July 2013, University of Leeds, UK Status quo of CIE work on colour rendering indices Hirohisa Yaguchi Chiba University,
More informationChapter Objectives. Color Management. Color Management. Chapter Objectives 1/27/12. Beyond Design
1/27/12 Copyright 2009 Fairchild Books All rights reserved. No part of this presentation covered by the copyright hereon may be reproduced or used in any form or by any means graphic, electronic, or mechanical,
More informationHow Big Is Color? John Seymour* Keywords: Halftone, Scanning, Moiré, Screening, Fourier, Resolution, Colorimetry. Abstract
How Big Is olor? John Seymour* eywords: Halftone, Scanning,, Screening, Fourier, Resolution, olorimetry Abstract What is the physical size of the smallest identifiable color? A person with 20/20 vision
More informationAchieving Great Output Quality with Your Paper. Lou Prestia, Sr. Product Line Manager
Achieving Great Output Quality with Your Paper Lou Prestia, Sr. Product Line Manager Agenda Paper manufacturing and characteristics Quality considerations for stock selection Proper storage techniques
More informationUsing Color Appearance Models in Device-Independent Color Imaging. R. I. T Munsell Color Science Laboratory
Using Color Appearance Models in Device-Independent Color Imaging The Problem Jackson, McDonald, and Freeman, Computer Generated Color, (1994). MacUser, April (1996) The Solution Specify Color Independent
More informationDeliverable 5.2. Quality Control Guidelines Doc 4 technical paper for professionals. EMSPI: Energy Management Standardization in Printing Industry
Deliverable 5.2 Quality Control Guidelines Doc 4 technical paper for professionals EMSPI: Energy Management Standardization in Printing Industry Energy Management Standardization in Printing Industry Page
More informationColor Quality Scale (CQS): quality of light sources
Color Quality Scale (CQS): Measuring the color quality of light sources Wendy Davis wendy.davis@nist.gov O ti l T h l Di i i Optical Technology Division National Institute of Standards and Technology Copyright
More informationIdealliance ISO/PAS Certification Program Program Description v5 1. Introduction
Idealliance ISO/PAS 15339 Certification Program Program Description v5 1. Introduction 1.1 Background Idealliance ISO/PAS 15339 Certification is an expanded compliance program to the Digital Press Certification
More informationCIE TC 8-16 Consistent Colour Appearance (CCA) in a Single Reproduction Medium. Informal Workshop at RIT 1 st June 2017 W Craig Revie
CIE TC 8-16 Consistent Colour Appearance (CCA) in a Single Reproduction Medium Informal Workshop at RIT 1 st June 2017 W Craig Revie Overview A Increasing gamut size B Q1: why do images in set B have a
More informationIFRA-Check: Evaluation of printing quality on the basis of worldwide valid standards. Instructions
IFRA-Check: Evaluation of printing quality on the basis of worldwide valid standards Instructions V091005 Page 1 of 15 Thank You For your interest in using the IFRA-Check tool to submit your newspaper
More informationSVENSK STANDARD SS-ISO :2004
SVENSK STANDARD Fastställd 2004-12-03 Utgåva 2 Grafisk teknik - Processtyrning vid framställning av färgseparationer, provtryck och upplagetryck - Del 2: Offsettryckning (ISO 12647-2:2004, IDT) Graphic
More informationISO 3664 INTERNATIONAL STANDARD. Graphic technology and photography Viewing conditions
INTERNATIONAL STANDARD ISO 3664 Third edition 2009-04-15 Graphic technology and photography Viewing conditions Technologie graphique et photographie Conditions d'examen visuel Reference number ISO 3664:2009(E)
More informationColour analysis of inhomogeneous stains on textile using flatbed scanning and image analysis
Colour analysis of inhomogeneous stains on textile using flatbed scanning and image analysis Gerard van Dalen; Aat Don, Jegor Veldt, Erik Krijnen and Michiel Gribnau, Unilever Research & Development; P.O.
More informationA Custom Approach to Color Control Visible and Beyond
THERM0PLASTIC ELASTOMERS STRUCTURAL WEAR CONDUCTIVE COLOR FLAME RETARDANT A Custom Approach to Color Control Visible and Beyond Jesse Dulek Color Engineer RTP Company Outline RTP Color Division Color Communication
More informationPermanence of Inkjet Prints in Relation to Typographic and Colorimetric Characteristics
International Circular of Graphic Education and Research, No. 7, 2014 Permanence of Inkjet Prints in Relation to Typographic and Colorimetric Characteristics Klementina Možina, Julija Aguši, Blaž Rat and
More informationspecification cylon colorimeter
specification cylon colorimeter Contents 1 Cylon: innovative ring of light... 3 2 Highlights... 4 3 Cylon general specifications... 4 4 Cylon colorimeter spectral sensitivity... 5 5 Cylon colorimeter specifications...
More informationAesthetic Consideration and Shade Selection for Ceramic Restorations
Aesthetic Consideration and Shade Selection for Ceramic Restorations Mohammed Alfarsi BDS, MDSc(Pros), PhD www.drmohdalfarsi.com Overview Aesthetic Consideration and Shade Selection for Ceramic Restorations
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationChroma. Optical Spectral Analysis and Color Measurement
Chroma Optical Spectral Analysis and Color Measurement Seeing is not seeing. Seeing is thinking. Contents Methods and Data Sources page 4 // 5 Measurement and Series Measurement page 6 // 7 Spectral Analysis
More informationColorimetry vs. Densitometry in the Selection of Ink-jet Colorants
Colorimetry vs. Densitometry in the Selection of Ink-jet Colorants E. Baumann, M. Fryberg, R. Hofmann, and M. Meissner ILFORD Imaging Switzerland GmbH Marly, Switzerland Abstract The gamut performance
More informationFrequently Asked Questions (FAQs) Pertaining to G7,GRACoL and ISO
Frequently Asked Questions (FAQs) Pertaining to G7,GRACoL and ISO 12647-2 What is G7? Developed by IDEAlliance, and the GRACoL committee, G7 is a calibration and process control methodology used to align
More informationPastes based on organic pigments for colourmatching of RAL shades
ICS Seminar 8th & 9th November Pastes based on organic pigments for colourmatching of RAL shades Who is Helio Beit? - Company Founded 2015 (family owned) - Previously operating as a part of Bollig & Kemper
More informationThe Principles of Chromatics
The Principles of Chromatics 03/20/07 2 Light Electromagnetic radiation, that produces a sight perception when being hit directly in the eye The wavelength of visible light is 400-700 nm 1 03/20/07 3 Visible
More informationPrinect. Color and Quality. Guideline for Prinect Axis Control for printing presses with Prinect CP2000 Center
Prinect Color and Quality Guideline for Prinect Axis Control for printing presses with Prinect CP2000 Center Table of contents 1 Introduction 4 1.1 Definitions 4 1.2 Principles of the Heidelberg color
More informationReport No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498
More informationInk Properties to maximise production potential!
Ink Properties to maximise production potential! Pira Conference Future of Inks and Coatings for Packaging 27 th & 28 th September 2006 Good morning/afternoon Ladies and Gentlemen. Thank you Pira for the
More informationThe appearance of the visual effect simultaneous contrast depending on the printing substrate
The appearance of the visual effect simultaneous contrast depending on the printing substrate Krunoslav Hajdek ¹, Ivan Budimir ², Katja Krizmanić ³ 1 Univerity North, Varaždin 2 Faculty of Graphic Arts,
More informationLM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories
More informationUnderlying Factors for Consistent Color Appearance (CCA) and developing CCA metric
Underlying Factors for Consistent Color Appearance (CCA) and developing CCA metric Elena Fedorovskaya & Robert Chung - RIT David Hunter & Pierre Urbain- ChromaChecker.com CRPC1 CRPC2 CRPC3 CRPC4 CRPC5
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More informationColour accuracy assessment of the SilverFast software with the scanner Epson V750. 1x IT8.7/2 chart 1x DVD SilverFast software package
Page 1 of 6 Order from: Mr. Rossee Luisenweg 6-8 24105 Kiel Your contact Andreas Kraushaar [Dipl.-Ing.] Tel. +49 89. 43 182-335 kraushaar@fogra.org Order of: 17.06.2009 Mr. Rossee 4. September 2009 Report
More informationReport No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary
Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)
More informationICC Votable Proposal Submission Colorimetric Intent Image State Tag Proposal
ICC Votable Proposal Submission Colorimetric Intent Image State Tag Proposal Proposers: Jack Holm, Eric Walowit & Ann McCarthy Date: 16 June 2006 Proposal Version 1.2 1. Introduction: The ICC v4 specification
More informationBandpass Edge Dichroic Notch & More
Edmund Optics BROCHURE Filters COPYRIGHT 217 EDMUND OPTICS, INC. ALL RIGHTS RESERVED 1/17 Bandpass Edge Dichroic Notch & More Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488 EUROPE:
More informationYoshi Ohno. ssl.iea-4e.org. SSL Annex IC 2017 Task Leader (CIE President, NIST Fellow) National Institute of Standards and Technology, USA
ssl.iea-4e.org Yoshi Ohno SSL Annex IC 2017 Task Leader (CIE President, NIST Fellow) National Institute of Standards and Technology, USA SSL Annex Conference; 23 November 2017 1 400 450 500 550 600 650
More informationISO INTERNATIONAL STANDARD. Graphic technology Spectral measurement and colorimetric computation for graphic arts images
INTERNATIONAL STANDARD ISO 13655 Second edition 2009-12-15 Graphic technology Spectral measurement and colorimetric computation for graphic arts images Technologie graphique Mesurage spectral et calcul
More informationFits and Tolerances. Prof Ahmed Kovacevic
ME 1110 Engineering Practice 1 Engineering Drawing and Design - Lecture 7 Fits and Tolerances Prof Ahmed Kovacevic School of Engineering and Mathematical Sciences Room C130, Phone: 8780, E-Mail: a.kovacevic@city.ac.uk
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More informationCamera Calibration Certificate No: DMC III 27542
Calibration DMC III Camera Calibration Certificate No: DMC III 27542 For Peregrine Aerial Surveys, Inc. #201 1255 Townline Road Abbotsford, B.C. V2T 6E1 Canada Calib_DMCIII_27542.docx Document Version
More informationISO 3664 INTERNATIONAL STANDARD. Graphic technology and photography Viewing conditions
INTERNATIONAL STANDARD ISO 3664 Third edition 2009-04-15 Graphic technology and photography Viewing conditions Technologie graphique et photographie Conditions d'examen visuel Reference number ISO 3664:2009(E)