IESNA LM Test Report
|
|
- Benjamin Reynolds
- 5 years ago
- Views:
Transcription
1 IESNA LM Test Report Photometric testing and evaluation in accordance with LM Report prepared for: R. STAHL Schaltgeräte GmbH Nordstraße Weimar / Germany Report number: LM / 02 Sample tested: 6002/ Manufacturer: R. STAHL Schaltgeräte GmbH Testing performed by : ILEXA GbR Werner-von-Siemens-Straße 4a Ilmenau / Germany Tel.: (+49) 3677 / Fax: (+49) 3677 / Internet: Laboratory : Ilmenau University of Technology Group of Lighting Engineering Prof.-Schmidt-Str Ilmenau / Germany
2 Table of contents 1. Description of test sample General Informationen Manufacturer specifications Pictures Scope of testing Equipment Additional information Test Results Results goniophotometer Illuminance plots Candela plots Results spectroradiometer Relative spectral distribution Chromaticity diagram Color calculation...13 General Information This report may not be reproduced except in full without permission of ILEXA GbR. This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. Wladimir Jordanow ILEXA GbR president Date: IESNA LM Test Report - Nr. LM / 02 Page 2 of 11
3 1. Description of test sample 1.1. General Informationen Sample received: Manufacturer: R. STAHL Schaltgeräte GmbH Nordstraße Weimar / Germany Model number: 6002/ (Muster WE ) Model type: Length / Width / Height: Luminaire 1310 mm / 185 mm / 125 mm 1.2. Manufacturer specifications Voltage [V]: 230 AC Frequency [Hz]: Pictures Figure 1: Luminaire as measured Date: IESNA LM Test Report - Nr. LM / 02 Page 3 of 11
4 2. Scope of testing Photometric and electrical testing in accordance with IESNA LM IES (Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products). All measurements are made using the goniophotometer / spectroradiometer test method. The spectral values are measured at a given direction with vertikal angle theta= 0. Date of test: Report and test prepared by: Kranhold / ILEXA GbR 3. Equipment Testing is performed in accordance with the procedures outlined in IESNA LM The sample is evaluated for photometric and electrical characteristics using a goniophotometer, located in an temperature - controlled, draft free photometric laboratory. Item Manufacturer Model Calibration due Goniophotometer TechnoTeam RiGo801 yearly Spectroradiometer Jeti specbos 1211 yearly Power Supply Statron AG BE2/01H-IP-R20-B N/A Digital Power Meter Yokogawa WT110 N/A Table 3.1: Test Instrumentation 4. Additional information (none) Date: IESNA LM Test Report - Nr. LM / 02 Page 4 of 11
5 5. Test Results The results were obtained after stabilization of the sample in accordance with the requirements set forth in section 5.0 of IES LM Goniophotometer Spectroradiometer Total luminous flux [lm] 4695,8 - Luminous efficacy [lm/w] 94 - Correlated color temperature (CCT) [K] Color rendering index (CRI - R a ) - 88,52 Chromaticity (x / y) - 0,3532 / 0,3599 Table 5.1: Photometric results R1 R2 R3 R4 R5 R6 R7 R8 88,2 91,4 93,1 89,5 88,0 87,6 91,7 78,7 R9 R10 R11 R12 R13 R14 R15 39,9 78,7 89,1 69,1 89,0 96,0 84,2 Table 5.2: Color rendering index color samples Input power (W) 49,7 Input voltage (V) 231,5 AC Input current (A) 0,2243 Input frequency (Hz) 50 Table 5.3: Electrical results Orientation (burning position) during test horizontal Prior operation time (minutes) 40 Stabilization time (minutes) 58 Total operating time (minutes) 1553 Ambient temperature ( C) 24,0 Table 5.4: Additional Parameters Date: IESNA LM Test Report - Nr. LM / 02 Page 5 of 11
6 6. Results goniophotometer 6.1. Illuminance plots tilt angle : 0,0 swivel angle: 0,0 mounting height: 3,0 m orientation : 0,0 light loss factor : 1,0 4 m 8,0 4 m , , ,0-6 m m Figure 2: Isolux diagram (mounting height 3m) Date: IESNA LM Test Report - Nr. LM / 02 Page 6 of 11
7 6.2. Candela plots Figure 3: 3D - luminous intensity distribution Date: IESNA LM Test Report - Nr. LM / 02 Page 7 of 11
8 cd C0,0-C180,0 C90,0-C270,0 Figure 4: Polar candela distribution I (cd) 00 C0,0 C90, Figure 5: Cartesian candela distribution Date: IESNA LM Test Report - Nr. LM / 02 Page 8 of 11
9 7. Results spectroradiometer 7.1. Relative spectral distribution 1 0,9 0,8 Relative spectral distribution 0,7 0,6 0,5 0,4 0,3 0,2 0, Wavelength [nm] Figure 6: Relative spectral distribution Date: IESNA LM Test Report - Nr. LM / 02 Page 9 of 11
10 7.2. Chromaticity diagram Figure 7: Chromaticity diagram Tristimulus Value x 0,3532 y 0,3599 Table 7.1: Chromaticity coordinates The location on the diagram of the tristimulus coordinates are indicated by the blue axes on cross. Date: IESNA LM Test Report - Nr. LM / 02 Page 10 of 11
11 7.3. Color calculation Figure 8: Color calculation Color rendering index color samples CRI color samples CRI R1 88,2 R9 39,9 R2 91,4 R10 78,7 R3 93,1 R11 89,1 R4 89,5 R12 69,1 R5 88,0 R13 89,0 R6 87,6 R14 96,0 R7 91,7 R15 84,2 R8 78,7 Ra 88,52 CCT 4737 K Table 7.2: Color calculation CRI R1-R15, R a and Correlated color temperature Date: IESNA LM Test Report - Nr. LM / 02 Page 11 of 11
IESNA LM Test Report
IESNA LM79-2008 Test Report Photometric testing and evaluation in accordance with LM79-2008 Report prepared for: R. STAHL Schaltgeräte GmbH Nordstraße 10 99427 Weimar / Germany Report number: LM79201510-D
More informationTEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.
TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More informationAddress: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K
Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationOrb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.
Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance
More informationReport No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498
More informationOrb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.
Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance
More informationReport No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary
Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationOrb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.
Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)
More informationSample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:
IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave.
More informationTEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003
TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,
More informationReport No.: HZ c
Test Summary Model L13T8DF450-CG4 Luminous Efficacy (Lumens /Watt) 121.4 Total Luminous Flux (Lumens) 2038.0 Power (Watts)/2 16.79 Power Factor 0.9957 CCT (K) 4912 CRI 81.5 Stabilization Time (Light &
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119
More informationReport No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More information71332 LED Dusk To Dawn (Area Light)
71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:
More informationLM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A
LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:
More informationNVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)
LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting
More informationReport No.: EASZE Page 2 of 14
Report No.: EASZE03220005 Page 2 of 14 1 SUMMARY Parameter Result Total Luminous Flux 1680.9 lm Luminous Efficacy 83.34 lm/w Power Factor 0.9829 Color Rendering Index (Ra) 83.7 Correlated Color Temperature
More informationLM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationLM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationLM Test. for LED. Cabinet
LM-79-08 Test Report for ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China 5190855 LED Cabinet Light Model: 535021## #(##=11-30)
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 100W LED AREA LIGHT
More informationLED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.
71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage
More informationReport No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary
Test Summary Model MT8N28 Luminous Efficacy (Lumens /Watt) 101.5 Total Luminous Flux (Lumens) 1860.0 Power (Watts)/2 18.32 Power Factor 0.9972 CCT (K) 3948 CRI 82.9 Stabilization Time (Light & Power) 60
More informationCat# LED Wall-PACK
Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Test Laboratory & Address:
More informationLM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50
LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationReport No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample
Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &
More informationL Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR
Quality Assured NVLAP LAB CODE 200960-0 L 1-79-08 Test Report for EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Laboratory: Leading Testing Laboratories
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 25W 4-FT DIRECTFIT
More informationReport No.: HZ d
Test Summary Model LLT-4-T8-15W-DBA-C-50K Luminous Efficacy (Lumens /Watt) 112.3 Total Luminous Flux (Lumens) 1953.0 Power (Watts)/2 17.39 Power Factor 0.9974 CCT (K) 5140 CRI 82.9 Stabilization Time (Light
More informationREPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045
FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G101555841 Date: March 21, 2014 REPORT NO. 101555841CRT-001 TEST OF ONE LED
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:
More informationDRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.
IESNA SUSTAINING MEMBER Test report of IES LM-79-08 Ref. No.: LCGP14100013 Date of issue Oct 18, 2014 Version 1.0 Total pages: 11 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Brendan Drew Product Manager MaxLite Description of Sample: 36inch80CRI 2700K
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 11W LED OMNI A19
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1
More informationNVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006
LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Ref. No.: LCZP15060026 Date of issue June 5, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Ramesh Raghavan Product Manager MaxLite Description of Sample: 5-6" Downlight
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W
More informationIES LM MEASUREMENT AND TEST REPORT For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W48-40K-D-T3-S
More informationLM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories
More informationApprovedMethod: Electricaland Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Date of issue Mar 28, 2015 Version 1.0 Total pages: 24 Test report of IES LM-79-08 ApprovedMethod: Electricaland Photometric Measurements of Solid-State Lighting Products Rendered
More informationNVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006
LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Ref. No.: LCGP15040508 Date of issue June 4, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationNVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires
LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationNVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationNVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013
LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationLM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard
Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1
More informationNVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730
LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationREVOLUTION LIGHTING TECHNOLOGIES INC
LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-010 TEST OF PAR 38 LED LAMPS MODEL NOS. S8854 / S8861
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-018 TEST OF PAR 30L LED LAMPS MODEL NOS. S8814 / S8821
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-039 TEST OF LED CANDLE LAMPS MODEL NOS. S8899 / S8903
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-036 TEST OF LED CANDLE LAMPS MODEL NOS. S8891 / S8894
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G101183506 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Date: June 6, 2013 REPORT NO. 101183506CRT-001 TEST OF ONE LED FLOOD
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Christian Groom Management Associate MaxLite Description of Sample: CPL Slim
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.
More informationNVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA
LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730
Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More information