Catalog number Lens Option Very Narrow without diffuser Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies
|
|
- Theodore Manning
- 5 years ago
- Views:
Transcription
1 Exterior 200 LED, Very Narrow (Balanced white 5600 Kelvin. Without diffuser) (13 ) Photometric Report Martin R&D Optics Laboratory, 31-Oct-2007 Data sheet conforms to American National Standard E Product Exterior 200 LED Catalog number Lens Option Very Narrow without diffuser IES file Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a single cell THOMA Color Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 2 increments in the horizontal plane (rotational) and 2 increments in the vertical plane (radial). Luxeon K2 LED s. 9 x red, 9 x green, 9 x royal blue, 9 x amber, 8 x white hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 132 W AC supply 231 V/50Hz Lamp age 1 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 1500 lumens 1300 lumens 640 lumens 11.5 lumens per watt Illuminance Cutoff angle 36 One-tenth-peak angle 27 Half-peak angle 13 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type 2-20 meters candela Far field
2 100%=220 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
3
4 Exterior 200 LED, Narrow (Balanced white 5600 Kelvin) (21 ) Photometric Report Martin R&D Optics Laboratory, 26-Oct-2007 Data sheet conforms to American National Standard E Product Exterior 200 LED Catalog number Lens Option Narrow IES file Exterior200LED_Narrow_5600Kelvin.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a single cell THOMA Color Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 2 increments in the horizontal plane (rotational) and 2 increments in the vertical plane (radial). Luxeon K2 LED s. 9 x red, 9 x green, 9 x royal blue, 9 x amber, 8 x white hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 132 W AC supply 230 V/50Hz Lamp age 1 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 1400 lumens 1200 lumens 620 lumens 10.7 lumens per watt Illuminance Cutoff angle 56 One-tenth-peak angle 42 Half-peak angle 21 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type 2-20 meters 8300 candela Far field
5 100%=83 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
6
7 Exterior 200 LED, Medium (Balanced white 5600 Kelvin) (27 ) Photometric Report Martin R&D Optics Laboratory, 27-Nov-2007 Data sheet conforms to American National Standard E Product Exterior 200 LED Catalog number Lens Option Medium IES file Exterior200LED_Medium_5600Kelvin.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a single cell THOMA Color Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 3 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). Luxeon K2 LED s. 9 x red, 9 x green, 9 x royal blue, 9 x amber, 8 x white hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 132 W AC supply 231 V/50Hz Lamp age 1 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 1300 lumens 1100 lumens 580 lumens 9.8 lumens per watt Illuminance Cutoff angle 72 One-tenth-peak angle 55 Half-peak angle 27 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type 2-20 meters 4400 candela Far field
8 100%=44 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
9
10 Exterior 200 LED, Wide (Balanced white 5600 Kelvin) (32 ) Photometric Report Martin R&D Optics Laboratory, 01-Nov-2007 Data sheet conforms to American National Standard E Product Exterior 200 LED Catalog number Lens Option Wide IES file Exterior200LED_Wide_5600Kelvin.ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a single cell THOMA Color Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type B photometry in 3 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). Luxeon K2 LED s. 9 x red, 9 x green, 9 x royal blue, 9 x amber, 8 x white hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 132 W AC supply 231 V/50Hz Lamp age 1 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 970 lumens 970 lumens 220 lumens 7.4 lumens per watt Illuminance Cutoff angle 127 One-tenth-peak angle 123 Half-peak angle 32 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type 2-20 meters 1300 candela Far field
11 100%=13 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
12
Product Tripix 300 Catalog number Lens Option Standard. Tripix300_ ies
Tripix 300 and 1200, Tripix 300 Standard (Without diffuser) (20 ) Photometric Report Martin R&D Optics Laboratory, 28-Jun-2010 Data sheet conforms to American National Standard E1.9-2001 Product Tripix
More informationExterior 400. Balanced white 6500Kelvin. Catalog number Lens Option Standard. Exterior400_Standard_ ies
Exterior 400, Balanced White 6500K Standard (Without diffuser) (7.5 ) Photometric Report Martin R&D Optics Laboratory, 19-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior
More informationMAC Quantum Profile Catalog number Lens Option Standard. MAC Quantum Profile_Standard_Minimum.ies
macquantumprofile, Standard Lens, Zoom at Minimum (12 ) Photometric Report Martin R&D Optics Laboratory, 15-Oct-2014 Data sheet conforms to American National Standard E1.9-2001 Product MAC Quantum Profile
More informationMAC Viper Profile Catalog number Lens Option Standard. MACViperProfile_Standard_Minimum.ies
macviperprofile, Standard Lens, Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product MAC Viper Profile
More informationMAC Viper Performance Catalog number Lens Option Standard without beamsmoother. MACViperPerformance_Standard without beamsmoother_minimum.
macviperperformance, Standard (beamsmoother removed), Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 0 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 50 foot mounting height.
More informationdaylight Spring 2014 College of Architecture, Texas Tech University 1
daylight Spring 2014 College of Architecture, Texas Tech University 1 artificial light Spring 2014 College of Architecture, Texas Tech University 2 artificial light Spring 2014 College of Architecture,
More informationElectrical Installation LectureNo.10 Dr.Mohammed Tawfeeq Al-Zuhairi. Luminous flux Luminous intensity Illuminance Luminance
Lighting Technology Basic parameters used in lighting Luminous flux Luminous intensity Illuminance Luminance Luminous flux Luminous flux (φ) is the light emitted by a source and is measured in lumens Symbol
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights 2 1 0 1 2 3.05.1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height..02.01.005.002.001 REPORT NUMBER: RAB00241
More informationOPTIMAL PERFORMANCE REFLECTOR
OPTIMAL PERFORMANCE REFLECTOR ELECTRICAL DATA COMMON TO ALL GENERATORS Input Voltage 0V-77V EMI/RFI Compliance FCC Part 8-A Voltage Fluctuation Tolerance ±0% Sound Rating Class A Input Frequency 0/60 Hz
More informationNo seasoning was performed in accordance with IESNA LM-79.
Test #: L01134102R01 Date: 1/28/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L01134102R01 LR24-5000L-50K-D-S Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L051411201 Date: 6/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L051411201 SPJ-720 Report Prepared For: SPJ LIGHTING
More informationLUXTRAN Luminaires for Tunnel Applications
PRODUCT FEATURES: Powered by distributed DC driver system; remotely-located for servicing convenience Suitable for supplemental lighting in transition zones with a ceiling or wall orientation Optical configurations
More informationCompany synopsis. Regulations and Standards
Goniophotometer Company synopsis Pleiades Instruments is an optoelectronic system maker, designing and manufacturing for you specific systems such as photometric measurement and customized systems. Designing
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730
Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE
More informationElectrical Illumination and Design
EE512 Electrical Illumination and Design Prepared by: Engr. John Michael Abrera Table of Contents 1. Photometry 2. Laws of Illumination 3. Coefficient of Utilization 1 Photometry Photometry Photometry
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationLIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808
LIGHT LABORATORY, INC. 8165 E Kaiser Blvd. Anaheim, CA 92808 SHT 1 OF 5 Test #: L06110908 Date: 7/22/2011 Luminaire Photometric Performance LM-79-2008 Manufacturer: Model Number: ELATION LIGHTING TVL 2000
More informationFFW / LED Flood / Wall Pack Combo
The FFW LED/ Wall Pack Combo is an efficient, energy saving solution for replacing metal halide and high-pressure sodium fixtures. The combo design is an ideal lighting option for security, pathways, perimeters
More informationLUXTRAN Luminaires for Tunnel Applications
PRODUCT FEATURES: Powered by distributed DC driver system; remotely-located for servicing convenience Suitable for supplemental lighting in transition zones with a ceiling or wall orientation Optical configurations
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:
More informationEquipment Used Model No Stock No Calibration Due Date
Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SANDRA STREET, FRANKLIN PARK, IL 60131
Test #: L031611002 Date: 4/11/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L031611002 GARVIN INDUSTRIES
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113411R1 Date: 1/28/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: Model Number: L113411R1 LR24-4L-5K-D-S Report Prepared For: Raffino
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For Lumificient Corp Deborah Jones 8752 Monticello Lane North Maple Grove, MN 55369-4549 Catalog Number EVG236-BB-AC-NW-UL1-XX
More informationClient submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.
Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.
More informationLED14.5WPAR30S/FL/827-DIM
LED14.5WPAR30S/FL/827-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3 TEST FACILITY DESCRIPTION... 4 1.4 TEST EQUIPMENT
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number UPC Number Description 71466A 60198671466 LED Vandal Resistant Canopy Light 80W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared
More information71332 LED Dusk To Dawn (Area Light)
71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113141 Date: 1/8/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L113141 Model Number: LR22-33L-35K Report Prepared For: Raffino Inc. Test:
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED114DMV35.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 72662 UPC Number 60198672662 Description 8" Recessed Downlight 25 Watt Features Phillips LUMILED LUXEON 3030 LED's Can be installed in most 8" Downlights Aluminum Housing/Trim - paintable
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED180DMV40.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies
More informationETC GENERAL INFORMATION ORDERING INFORMATION. Selador Lustr CE. Accessories
GENERAL INFORMATION The Selador Series high power Lustr fixture is ideal for stage and studio lighting as a key or fill light as well as stage washes. It produces the subtle tinted colours that lighting
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationRecommendations for Testing and Evaluating Under-cabinet Luminaires
Recommendations for Testing and Evaluating Under-cabinet Luminaires Volume 2, Issue 3 2007 A publication of the Alliance for Solid-State Illumination Systems and Technologies Copyright 2007 by the Alliance
More informationCatalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White
Catalog Number 71694 UPC Number 60198671694 Description LED Spot Bullet Flood Light 42W 4204 Lumens White QPL ID # PWG6GTSQ Features Philips Lumiled LUXEON 3030 2D Voltage: 120-277VAC Isolated Driver Compartment
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407206 Date: 12/11/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407206 Report Prepared For: Cast Lighting 1120-A Goffle
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationMANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: ROADWAY Date: S01130101 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared
More informationMoon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards.
Test #: L061402510 Date: 6/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L061402510 LED MV120V R30 14W 5K FL Report Prepared
More informationPhotometric Indoor Test Report
Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date
More informationTEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.
TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:
More informationAccento. Powerful LED Accent and Feature light range
Accento Powerful LED Accent and Feature light range 64 MEGABAY LED LUMINAIRES A5 Accento 5W A8 Accento 8W A12 Accento 12W Accento Accento LED ACCENT & FEATURE LIGHT The Accento range of multipurpose exterior
More informationSample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:
IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave.
More informationBasic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)
Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Accent Lighting Directional lighting to emphasize a particular object or draw attention to a display
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506
Report No: L071407704 Date: 8/6/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407704 Report Prepared For: Cast Lighting 1120-A Goffle
More informationQPL ID # PLG2YNJ831VZ
Catalog Number 71732 UPC Number 60198671732 Description UFO High Bay 100W Features Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast Aluminum Housing Polycarbonate Lens Superior
More informationTechnical requirements. for solid-state lighting products (2010)
Technical requirements for solid-state lighting products (2010) I Contents 1. Definitions... 1 2. Scopes and requirements... 3 (1) Self-ballasted LED reflectors... 3 1 Scopes... 3 Technical requirements...
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W
More informationPhotometric Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2017, IES TM-30-2015 UL LLC 1075 W Lambert
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061507817R01 Date: 8/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061507817R01 Beachside
More informationRoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens
Cat# 71552 15 Watt 1/2" Adjustable Knuckle Mount RoHS QPL ID # P4K7RKA9 Model: 71552 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.
Report No: L051604201 Date: 6/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051604201 Lexington Lighting
More informationLighting Sciences
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.
Report No: L111407108 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407108 Report Prepared For: Cast Lighting 1120-A Goffle
More informationLM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard
Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1
More informationTEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003
TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,
More informationLighting Terminologies Introduction
Lighting Terminologies Introduction A basic understanding of lighting fundamentals is essential for specifiers and decision makers who make decisions about lighting design, installation and upgrades. Radiometry
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71462 UPC Number 60198671462 Description LED Vandal Resistant Canopy Light 40W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationCat# LED Wall-PACK
Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationEiKO Global, LLC W. 84th Street, Shawnee, KS 66227
Report No: L011508802 Date: 2/19/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011508802 Report Prepared For: EiKO Global, LLC 23220 W.
More informationLighting Sciences, Inc.
Lighting Sciences, Inc. Color and Photometric Testing, According to IESNA LM 79 Standards and Procedures, Test Report Files for: Par 30, 9W, DWF, Dimmable, 120V, Glass (SKU #180064) Seesmart 4139 Guardian
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationReport No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063
Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationNOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH
NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH The importance of Lighting Math: Calculations can determine the light levels Calculations can determine the required quantity of fixtures Calculations
More informationRevolution Lighting 4139 Guardian St. Simi Valley CA 93063
Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley
More informationETC. O r d e r i n g i n f o r m a t i o n. G e n e r a l i n f o r m a t i o n. Selador Paletta
G e n e r a l i n f o r m a t i o n The Selador Series medium power, low-profile Paletta fixture is ideal for stage and studio lighting as side light, down light, fill light or cyc lighting producing the
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
More informationIESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG
IESNA LM-79: 2008 Measurement and Test Report for Green Creative Ltd. Room 1206-7, New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Sep 02,2013 Product Name: LED PAR30 Model No: 14PAR30G3DIM/827FL40
More informationSolid-State Lighting Photometry Issues
Les Industries Spectralux Inc. Spectralux Industries Inc. 2750 Sabourin, Saint-Laurent (Québec) H4S 1M2 Canada Tél.:(514) 332-0082 Fax : (514) 332-3590 www.spectralux.ca Solid-State Lighting Photometry
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L041609601 Date: 5/5/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609601 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationChecked X.CAO
REPORT NUMBER: RAB01900 PAGE: 1 OF 7 CATALOG NUMBER: BULLET12Y LUMINAIRE: CAST FINNED METAL HEAT SINK, MOLDED TEXTURED PLASTIC REFLECTOR WITH SEMI-DIFFUSE FINISH, 1 CIRCUIT BOARD WITH 24 LEDS, CLEAR MICRO-PRISMATIC
More informationNVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)
LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L10131601 Date: 10/10/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L10131601 ELED Strip TW BOTH A Report Prepared
More informationCONE THROUGH MAXIMUM CANDELA 57.5 (Degrees Vertical)
REPORT NUMBER: ITL72395 PAGE: 2 OF 7 PREPARED FOR: ECONOLIGHT, A DIVISION OF RUUD LIGHTING CATALOG NUMBER: E-WP4L06CZ LUMINAIRE: CAST BLACK PAINTED FINNED METAL HOUSING, 2 CIRCUIT BOARDS EACH WITH ONE
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationBARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649
Report No: L101601204 Date: 10/18/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L101601204 Report Prepared For: BARTCO Lighting 5761 Research
More information