Results of Proficiency Test AZO dyes in textile February 2017

Size: px
Start display at page:

Download "Results of Proficiency Test AZO dyes in textile February 2017"

Transcription

1 Results of Proficiency Test AZO dyes in textile February 2017 Organised by: Author: Correctors: Report: (iis) Spijkenisse, the Netherlands ing. A.S. Noordman de Neef dr. R.G. Visser, ing. R.J. Starink iis17a01 April 2017

2 CONTENTS 1 INTRODUCTION SET UP ACCREDITATION PROTOCOL CONFIDENTIALITY STATEMENT SAMPLES ANALYSES RESULTS STATISTICS GRAPHICS Z-SCORES EVALUATION EVALUATION PER SAMPLE AND PER COMPONENT PERFORMANCE EVALUATION FOR THE GROUP OF LABORATORIES COMPARISON WITH PREVIOUS INTERLABORATORY STUDIES DISCUSSION CONCLUSION Appendices: 1. Data and statistical results Summary of other reported results Analytical details List of participants Abbreviations and literature AZO dyes in textile: iis17a01 page 2 of 44

3 1 INTRODUCTION The (iis) organizes a proficiency test (PT) for banned aromatic amines from AZO dyes in textile every year since During the annual proficiency testing program 2016/2017, it was decided to continue the PT for the analyses of banned aromatic amines from AZO dyes in textile. In this interlaboratory study, 170 laboratories in 34 different countries registered for participation (see appendix 4). In this report, the results of the 2017 PT are presented and discussed. This report is also electronically available through the iis website 2 SET UP The (iis) in Spijkenisse, the Netherlands, was the organiser of this proficiency test (PT). Sample analyses for fit-for-use and homogeneity testing were subcontracted to an ISO/IEC accredited laboratory. It was decided to send 2 different textile samples (a cotton sample, labelled #17515 and a polyamide sample, labelled #17516), each dyed with different AZO dyes. Both samples were especially prepared by a third party. The participants were requested to report test results using the indicated units and to report rounded and unrounded test results. The unrounded test results were preferably used for statistical evaluation. 2.1 ACCREDITATION The in Spijkenisse, the Netherlands, is accredited in agreement with ISO/IEC 17043:2010 (R007), since January 2000, by the Dutch Accreditation Council (Raad voor Accreditatie). This PT falls under the accredited scope. This ensures strict adherence to protocols for sample preparation and statistical evaluation and 100% confidentiality of participant s data. Feedback from the participants on the reported data is encouraged and customer s satisfaction is measured on regular basis by sending out questionnaires. 2.2 PROTOCOL The protocol followed in the organisation of this PT was the one as described for proficiency testing in the report iis Interlaboratory Studies: Protocol for the Organisation, Statistics and Evaluation of March 2017 (iis-protocol, version 3.4). This protocol is electronically available through the iis website from the FAQ page. 2.3 CONFIDENTIALITY STATEMENT All data presented in this report must be regarded as confidential and for use by the participating companies only. Disclosure of the information in this report is only allowed by means of the entire report. Use of the contents of this report for third parties is only allowed by written permission of the. Disclosure of the identity of one or more of the participating companies will be done only after receipt of a written agreement of the companies involved. AZO dyes in textile: iis17a01 page 3 of 44

4 2.4 SAMPLES Two different bulk textile samples were used in this proficiency test. The first one, a black cotton (sample #17515) was a real live sample (black jeans) and obtained from a participating laboratory. The other one, a rose polyamide textile (sample #17516) was dyed with different AZO-dyes. From the first batch, 194 samples with small pieces of fabric, of approximately 1.6 gram were prepared and labelled # From the second batch, 170 samples with small pieces of fabric, of approximately 3 gram were prepared and labelled # The homogeneity of the subsamples of #17515 was checked by determination of 3,3 -dimethoxybenzidine on eigth stratified randomly selected samples, see table 1 for the test results. 3,3 -dimethoxybenzidine in mg/kg sample # sample # sample # sample # sample # sample # sample # sample # Table 1: homogeneity test results of subsamples #17515 From the above test results, the repeatability was calculated and compared with the corresponding repeatability of the target test method in the next table. Unfortunately, comparison of the repeatability with 0.3 times the reproducibility of the reference test method as in agreement with the procedure of ISO 13528, Annex B2 was not possible as R/r of the reference test method is smaller than 3. 3,3 -dimethoxybenzidine in mg/kg r (observed) 5.0 reference test method EN : * R (ref. test method) 4.2 r (reference test method) 5.1 Table 2: repeatability of subsamples #17515 The homogeneity of the subsamples of #17516 was checked by determination of 3,3 -dimethylbenzidine and 2,4-Xylidine on eigth stratified randomly selected subsamples. See table 3 for the test results. AZO dyes in textile: iis17a01 page 4 of 44

5 3,3 -dimethylbenzidine in mg/kg sum of Xylidines in mg/kg *) sample # sample # sample # sample # sample # sample # sample # sample # Table 3: homogeneity test results of subsamples #17516 *) the sum of 2,4-Xylidine and 2,5-Xylidine was determined. Sample #17516 does not contain 2,6-Xylidine, see the discussion in paragraph 5. From the above test results, the repeatabilities were calculated and compared with 0.3 times the corresponding reproducibilities of the reference test method in agreement with the procedure of ISO 13528, Annex B2 in the next table: 3,3 -dimethylbenzidine in mg/kg sum of Xylidines in mg/kg *) r (observed) reference test method EN :2012 EN : * R (ref. test method) Table 4: repeatabilities of subsamples #17516 *) see comment at table 3 above. The calculated repeatabilities of the homogeneity test results were in agreement with the repeatabilities mentioned in (or estimated from) the reference test method. Therefore, homogeneity of the subsamples of #17515 and #17516 was assumed. To the participating laboratories was sent 1 sample labelled #17515 and 1 sample labelled #17516 on February 8, A letter of instructions was added to the sample package. 2.5 ANALYSES The participants were asked to determine the concentrations of 23 forbidden aromatic amines and o-anisidine, applying the analysis procedure that is routinely used in the laboratory. Also some analytical details were requested to be reported. Furthermore, the participants were instructed not to analyse for 4-Aminoazobenzene in sample #17515 as the sample amount was small (1.6 g) and the sample did not contain 4-Aminoazobenzene. In general in iis proficiency tests the sample size is 3 g. Sample #17515 was a real life sample and to be able to serve as many as possible participants the sample size was lowered and an extra instruction was given by that a smaller intake couldbe use because the sample was positive and also that no confirmation replicate had to be performed. AZO dyes in textile: iis17a01 page 5 of 44

6 It was explicitly requested to treat the samples as if they were routine samples, but not to perform the extraction step with Chlorobenzene. It was also requested to report the test results using the indicated units on the report form and not to round the test results, but to report as much significant figures as possible. It was also requested not to report less than test results, which are above the detection limit, because such test results cannot be used for meaningful statistical evaluation. To get comparable test results a detailed report form and a letter of instructions are prepared. The detailed report form and the letter of instructions are both made available on the data entry portal The participating laboratories were also requested to confirm the sample receipt on this data entry portal. The letter of instructions can also be downloaded from the iis website 3 RESULTS During five weeks after sample dispatch, the test results of the individual laboratories were gathered via the data entry portal The reported test results are tabulated per sample and per component in the appendix 1 of this report. The laboratories are represented by their code numbers. Directly after the deadline, a reminder was sent to those laboratories that did not report test results at that moment. Shortly after the deadline, the available test results were screened for suspect data. A test result was called suspect in case the Huber Elimination Rule (a robust outlier test) found it to be an outlier. The laboratories that produced these suspect data were asked to check the reported test results (no reanalyses). Additional or corrected test results are used for the data analysis and the original test results are placed under 'Remarks' in the test result tables in appendix 1. Test results that came in after the deadline were not taken into account in this screening for suspect data and thus these participants were not requested for checks. 3.1 STATISTICS The protocol followed in the organisation of this proficiency test was the one as described for proficiency testing in the report iis Interlaboratory Studies: Protocol for the Organisation, Statistics and Evaluation of March 2017 (iis-protocol, version 3.4). For the statistical evaluation the unrounded (when available) figures were used instead of the rounded test results. Test results reported as <... or >... were not used in the statistical evaluation. First, the normality of the distribution of the various data sets per determination was checked by means of the Lilliefors-test, a variant of the Kolmogorov-Smirnov test and by the calculation of skewness and kurtosis. Evaluation of the three normality indicators in AZO dyes in textile: iis17a01 page 6 of 44

7 combination with the visual evaluation of the graphic Kernel density plot, lead to judgement of the normality being either unknown, OK, suspect or not OK. After removal of outliers, this check was repeated. If a data set does not have a normal distribution, the results of the statistical evaluation should be used with due care. In accordance to ISO 5725 the original test results per determination were submitted subsequently to Dixon s, Grubbs and or Rosner s outlier tests. Outliers are marked by D(0.01) for the Dixon s test, by G(0.01) or DG(0.01) for the Grubbs test and by R(0.01) for the Rosner s test. Stragglers are marked by D(0.05) for the Dixon s test, by G(0.05) or DG(0.05) for the Grubbs test and by R(0.05) for the Rosner s test. Both outliers and stragglers were not included in the calculations of averages and standard deviations. For each assigned value the uncertainty was determined in accordance with ISO Subsequently the calculated uncertainty was evaluated against the respective requirement based on the target reproducibility in accordance with ISO When the uncertainty passed the evaluation no remarks are made in the report. However, when the uncertainty failed the evaluation it is mentioned in the report and it will have significant consequences for the evaluation of the test results. Finally, the reproducibilities were calculated from the standard deviations by multiplying them with a factor of GRAPHICS In order to visualise the data against the reproducibilities from literature, Gauss plots were made, using the sorted data for one determination (see appendix 1). On the Y-axis the reported test results are plotted. The corresponding laboratory numbers are on the X-axis. The straight horizontal line presents the consensus value (a trimmed mean). The four striped lines, parallel to the consensus value line, are the +3s, +2s, -2s and -3s target reproducibility limits of the selected reference test method. Outliers and other data, which were excluded from the calculations, are represented as a cross. Accepted data are represented as a triangle. Furthermore, Kernel Density Graphs were made. The Kernel Density Graph is a method for producing a smooth density approximation to a set of data that avoids some problems associated with histograms. Also a normal Gauss curve was projected over the Kernel Density Graph for reference. 3.3 Z-SCORES To evaluate the performance of the participating laboratories the z-scores were calculated. As it was decided to evaluate the performance of the participants in this proficiency test (PT) against the literature requirements, e.g. ISO reproducibilities, the z-scores were calculated using a target standard deviation. This results in an evaluation independent of the variation in this interlaboratory study. AZO dyes in textile: iis17a01 page 7 of 44

8 The target standard deviation was calculated from the literature reproducibility by division with 2.8. In case no literature reproducibility was available, other target values were used, like Horwitz. In some cases, a reproducibility based on former iis proficiency tests could be used. When a laboratory did use a test method with a reproducibility that is significantly different from the reproducibility of the reference test method used in this report, it is strongly advised to recalculate the z-score, while using the reproducibility of the actual test method used. This should be done in order to evaluate whether the reported test results are fit-for-purpose. The z-scores were calculated in accordance with: z (target) = (test result - average of PT) / target standard deviation The z (target) scores are listed in the test result tables in appendix 1. Absolute values for z<2 are very common and absolute values for z>3 are very rare. Therefore the usual interpretation of z-scores is as follows: z < 1 good 1 < z < 2 satisfactory 2 < z < 3 questionable 3 < z unsatisfactory 4 EVALUATION During the execution of this proficiency test some reporting problems occurred. Two participants reported the test results after the deadline and six participants did not report any test results. Finally, 164 participants did report 770 numerical test results. Observed were 18 outlying test results, which is 2.3% of the numerical test results. However, by exception 105 participants (14%!) reported a false positive concentration 2,6-Xylidine to be present in sample #17516 (see the discussion in paragraphs 4.1 and 5). In proficiency studies, outlier percentages of 3% - 7.5% are quite normal. Not all original data sets proved to have a normal Gaussian distribution. These are referred to as not OK or suspect. The statistical evaluation of these data sets should be used with due care, see also paragraph 3.1. AZO dyes in textile: iis17a01 page 8 of 44

9 4.1 EVALUATION PER SAMPLE AND PER COMPONENT In this section, the results are discussed per sample and per component. All statistical results reported on the textile samples are summarised in appendix 1 and all other reported test results of the most relevant aromatic amines present are summarised in appendix 2. Textile sample #17515: 3,3 -Dimethoxybenzidine (CASno ): The determination of this aromatic amine at a concentration level of 44 mg/kg was problematic. Three statistical outliers were observed. The calculated reproducibility after rejection of the statistical outliers is not in agreement with the reproducibility requirement estimated from the test method EN :2012. Textile sample #17516: 3,3 -Dimethylbenzidine (CASno ): The determination of this aromatic amine at a concentration level of 44 mg/kg was very problematic. Three statistical outliers were observed and one test result was excluded (see appendix 1). The calculated reproducibility after rejection of the suspect data is not at all in agreement with the reproducibility requirement estimated from the test method EN : ,4-Xylidine (CASno ): The determination of this aromatic amine at a concentration level of 105 mg/kg was problematic. Nine statistical outliers were observed and four test results were excluded (see appendix 1). The calculated reproducibility after rejection of the suspect data is not in agreement with the reproducibility requirement estimated from the test method EN :2012. See for more discussion paragraph 5. 2,6-Xylidine (CASno ): The determination of this aromatic amine was very problematic. It appeared that sample #17516 did not contain 2,6-Xylidine but the isomer 2,5-Xylidine. The 2,5- isomer was falsly interpreted as 2,6- Xylidine by 105! participants. Most likely 18 laboratories were able to separate the isomers correctly and to identify the peaks in the chromatograms to the correct isomers. It is noteworthy that the calculated reproducibility over the test results from those 18 participants is in good agreement with the reproducibility requirement estimated from the test method EN :2012. See also the discussion in paragraph 5. General: The large majority of participating laboratory did not detect any other banned aromatic amines than the four discussed above. Twelve participants reported also the presence of other banned aromatic amines at different concentration levels in sample #17515 (see Appendix 2). Seven participants reported also the presence of other banned aromatic amines at different concentration levels in sample #17516 (see Appendix 2). AZO dyes in textile: iis17a01 page 9 of 44

10 4.2 PERFORMANCE EVALUATION FOR THE GROUP OF LABORATORIES A comparison has been made between the reproducibilities as declared by the relevant reference test methods and the reproducibilities as found for the group of participating laboratories. The number of test results, the average results, the calculated reproducibilities (standard deviation*2.8) and the target reproducibilities, derived (or estimated) from the official test method EN are compared in the next two tables. Component unit n average 2.8 * sd R(lit) 3,3 -Dimethoxybenzidine mg/kg Table 5: reproducibilities of the aromatic amines in textile sample #17515 Component unit n average 2.8 * sd R(lit) 3,3 -Dimethylbenzidine mg/kg ,4-Xylidine mg/kg Table 6: reproducibilities of the aromatic amines in textile sample #17516 Without further statistical calculations, it can be concluded that the group of participating laboratories has some difficulties with the analyses at the investigated concentration levels, for the aromatic amines found. See also the discussion in paragraphs 4.1 and COMPARISON WITH PREVIOUS INTERLABORATORY STUDIES The variations over the reported test results of 3,3 -Dimethoxybenzidine and 2,4-Xylidine in this proficiency test are in line with the variations as observed in previous PTs and almost in agreement with the target reproducibilities estimated from the reference test method EN :2012, see table 7. The variation over the reported test results of 3,3 - Dimethylbenzidine in this proficiency test is in line with the variations as observed in previous PTs but not at all in agreement with the target reproducibilities estimated from the reference test method EN :2012, see table 7. Parameter Feb. Feb. March April March target PTs 4-Aminodiphenyl n.e. n.e. n.e. (21%)* n.e % 28% Benzidine n.e % 20% 15% n.e % 14% 4-Chloro-o-toluidine n.e. n.e. n.e. 24% n.e. n.e. 16% 2-Naphtylamine n.e. n.e. n.e. n.e. n.e % 18% o-aminoazotoluene n.e. n.e. (48%)* n.e. n.e. n.e. 28% 4-Chloroaniline n.e. n.e. n.e. n.e. n.e. 27% 16% 2,4-Diaminoanisol n.e. n.e. n.e. n.e. 52% 24% 16% 4,4 -Diaminodiphenylmethane n.e. n.e. n.e. 21% n.e. 21% 15% 3,3 -Dimethoxybenzidine 17% 16% n.e. 21% 16% 17-31% 13% 3,3 -Dimethylbenzidine 36% n.e. 15% n.e. n.e % 18% 4,4 -Diamino-3,3 - n.e. n.e. n.e. n.e. n.e % 16% AZO dyes in textile: iis17a01 page 10 of 44

11 Parameter Feb. Feb. March April March target PTs dichlorodiphenylmethane 4,4 -Diaminodiphenylether n.e. n.e. n.e. n.e. n.e. 15% 16% 4,4 -Diaminodiphenylsulfide n.e. n.e. n.e. n.e. n.e % 16% 4,4 -Methyl-bis(2-chloroaniline) n.e. n.e. n.e. n.e. n.e. 43% 22% o-toluidine n.e. n.e. (70%)* 31% 27% 19-38% 22% Sum of o-aminoazotoluene and o-toluidine n.e. n.e. 34% n.e. n.e. n.e. 36% 2,4-Xylidine 19% n.e. n.e. n.e. n.e. n.e. 16% Table 7: long term development of uncertainties of aromatic amines in textile samples *) Concentration of this component was near or below detection limit or otherwise arbitrary Aromatic amines not mentioned in table 7 are not determined in a PT of iis yet. From the above table it is clear that the quality for the detected banned dyes is quite stable over the last years. 5 DISCUSSION It appeared that for the determination of 2,6-Xylidine in sample #17516 the majority of the participants (105!) could not recognise component 2,5-Xylidine correctly and had false positively identified this peak as 2,6-Xylidine. That sample #17516 did contain 2,5-Xylidine was not known to iis as the sum of 2,4- and 2,5-Xylidine was reported in the homogeneity test (see paragraph 2.4). Participants received a check who did report for 2,6-Xylidine: not detected or lower than. Fortunately, some participants responded very well to this check mail by showing to iis that the sample contained 2,5-Xylidine and not 2,6-Xylidine (see for example next chromatogram of one of these participants, (reported with permission)). This participant explained that if Xylidine is found positively the sample is spiked with 2,5- Xylidine to be able to differentiate component 2,5-Xylidine (which is allowed) from 2,4- Xylidine and 2,6-Xylidine (both not allowed). Corrected test results to replace the not detected or lower than test results were ignored and not detected or lower than were kept in the test results table for 2,6-Xylidine. It appeared that 18 participants reported not AZO dyes in textile: iis17a01 page 11 of 44

12 detected or lower than or had made a remark in the comments for 2,6-Xylidine and reported also a test value for 2,4-Xylidine. When the average over these 18 test results of 2,4-Xylidine is calculated it appeared that this is in line with the whole group. Therefore it is concluded that in general the group was able to identify 2,4-Xylidine correctly. When participants had reported a test value for 2,4-Xylidine and also for 2,6-Xylidine the sum was calculated. Unfortunately, the calculated reproducibility over this sum was not better than the calculated reproducibility for 2,4-Xylidine alone. Some participants mentioned to report the sum of Xylidines or reported identical test results for 2,4-Xylidine and 2,6-Xylidine. These test values were excluded for the statistical analysis as it was not clear whether the reported values were the sum or ½ times the sum. In this PT also some analytical details were asked (see appendix 3) to use for further analyses. It appeared that 92.5% of the participants is accredited for the determination of aromatic amines. As this is the majority of the group no separate statistical analysis has been performed. Another part of the analytical details was about the test conditions after cleavage at 70 C and before the analytical measurements. For example, the temperature during the evaporation of MTBE should not exceed 50 C, otherwise the aromatic amines may deteriorate and may not be detected anymore. Also the time needed between reduction and actual analysis may be important. The time and temperatures used to evaporate the extraction solvent varies over a wide range from only 1 minute upto 90 minutes. The majority of the laboratories (62%) had used temperatures between 40 and 50 C during 1 to 20 minutes. And 24 laboratories (19%) used temperatures from room temperature till 40 C during 3 to 15 minutes. Surprisingly no relation could be found between the conditions used and the concentration of aromatic amines detected, see below graphs in which evaporation temperature in C or evaporation time in minutes is plotted against the reported concentrations in mg/kg. 3,3'-Dimethoxybenzidine CAS no # ,3'-Dimethoxybenzidine CAS no # Conc. / (mg/kg) Conc. / (mg/kg) Evap. Temp. / C Evap. Time / min AZO dyes in textile: iis17a01 page 12 of 44

13 ,3'-Dimethylbenzidine CAS no # ,3'-Dimethylbenzidine CAS no #17516 Conc. / (mg/kg) Conc. / (mg/kg) Evap. Temp. / C Evap. Time / min Conc. / (mg/kg) ,4-Xylidine CAS no # Evap. Temp. / C Conc. / (mg/kg) ,4-Xylidine CAS no # Evap. Time / min The total time from the start of the reduction step till start of HPLC/GC analysis varies over a wide range from 1.2 till 72 hours. The majority of the group (68%) completed the whole analysis with in 4 hours. Again no relation could be found between the analysis time needed and the concentration of aromatic amines detected, see below graphs. Conc. / (mg/kg) ,3'-Dimethoxybenzidine CAS no #17515 Conc. / (mg/kg) ,3'-Dimethylbenzidine CAS no # Analysis Time / hours Analysis Time / hours Conc. / (mg/kg) ,4-Xylidine CAS no # Analysis Time / hours AZO dyes in textile: iis17a01 page 13 of 44

14 The tentative conclusion from the above investigation may be that the (in)stability of the investigated aromatic amines 3,3 -dimethoxybenzidine, 3,3 -dimethylbenzidine and 2,4- Xylidine is not the cause for the observed variation of the test results in this PT. Other factors like for example the calibration may be the cause of the observed variation. 6 CONCLUSION The variation in the test results observed may be caused by the preparation of the sample (reduction to release the aromatic amine and subsequent concentration) and/or by the analytical identification and quantification (incl. calibration). Consequently, the reproducibility may not be improved by only one change in the analysis. Each laboratory has to evaluate its performance in this study and make decisions about necessary corrective actions. Therefore, participation on a regular basis in this scheme could be helpful to improve the performance and thus increase of the quality of the analytical results. AZO dyes in textile: iis17a01 page 14 of 44

15 APPENDIX 1 Determination of 3,3 -Dimethoxybenzidine (CASno ) in sample #17515; results in mg/kg lab method value mark z(targ) remarks 213 EN In house EN C,R(0.05) first reported: In house EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN GB/T EN EN EN EN EN EN In house EN EN EN EN EN EN EN EN EN EN ISO EN EN EN EN EN EN EN EN EN EN EN EN EN ISO EN EN EN EN EN In house EN AZO dyes in textile: iis17a01 page 15 of 44

16 lab method value mark z(targ) remarks 2453 EN EN EN EN EN EN n.d possibly a false negative test result? 2482 EN EN EN EN EN EN EN EN EN ISO EN EN C first reported: In house EN EN EN EN EN EN EN EN GB/T EN EN EN EN EN R(0.01) EN EN EN EN EN n.d possibly a false negative test result? 2629 EN EN In house EN EN EN EN EN EN In house 79 C,R(0.01) 6.37 first reported: EN EN INH-7334 < 8 <-6.52 possibly a false negative test result? 2730 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN AZO dyes in textile: iis17a01 page 16 of 44

17 lab method value mark z(targ) remarks 3174 EN EN EN C 2.35 first reported: n.d. and test result as 3,3 -dimethylbenzidine 3185 EN EN EN EN EN EN EN In house EN EN EN EN EN EN EN EN EN normality suspect n 157 outliers 3 mean (n) st.dev. (n) R(calc.) R(EN :12) Compare R(ISO :17)= Kernel Density AZO dyes in textile: iis17a01 page 17 of 44

18 Determination of 3,3 -Dimethylbenzidine (CASno ) in sample #17516; results in mg/kg lab method value mark z(targ) remarks 213 EN EN In house In house EN EN EN EN ex test result excluded as 0 is not a true value 2115 EN EN R(0.01) EN EN EN EN EN EN EN EN EN EN EN EN EN GB/T EN EN EN EN EN EN EN In house EN EN EN EN EN EN EN EN EN EN ISO EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN In house EN AZO dyes in textile: iis17a01 page 18 of 44

19 lab method value mark z(targ) remarks 2453 EN R(0.05) EN EN EN EN EN EN EN EN EN EN EN C 0.27 first reported: EN EN C 0.75 first reported: n.d. and test result as 3,3 -dimethylbenzidine 2506 EN GB/T EN EN In house EN EN GB/T EN R(0.05) EN EN EN EN GB/T EN EN EN EN EN EN EN EN EN EN In house EN EN EN EN EN EN In house EN EN INH-7334 < 8 <-4.67 possibly a false negative test result? 2730 EN EN EN EN <5 <-5.06 possibly a false negative test result? 2773 EN EN C first reported: EN EN EN EN EN EN EN EN EN EN EN EN AZO dyes in textile: iis17a01 page 19 of 44

20 lab method value mark z(targ) remarks 3174 EN EN EN EN EN EN EN EN EN EN In house EN EN C first reported: EN EN EN EN EN EN normality OK n 152 outliers 3+1ex mean (n) st.dev. (n) R(calc.) R(EN :12) Compare R(ISO :17)= Kernel Density AZO dyes in textile: iis17a01 page 20 of 44

21 Determination of 2,4-Xylidine (CASno ), 2,6-Xylidine (CASno ) and sum of Xylidines in sample #17516; results in mg/kg lab method 24X mark z(targ) 26X mark z(targ) sum of Xylidines mark z(targ) 213 EN R(0.05) f+? EN In house f+? f+? In house n.d. f-? n.d n.d EN f+? EN f+? n.d EN see remarks EN R(0.01) f+? EN f+? EN f+? R(0.01) f+? EN f+? f+? EN f+? EN EN EN f+? EN EN f+? EN f+? EN f+? EN f+? EN < f+? EN EN f+? GB/T C f+? EN f+? EN f+? EN f+? EN f+? EN f+? EN f+? f+? EN In house f+? EN R(0.05) f+? EN f+? EN f+? EN f+? EN f+? EN n.d EN EN EN f+? EN ISO f+? f+? EN EN EN f+? EN f+? EN f+? EN f+? EN f+? EN C,R(0.01) f+? EN EN EN < EN f+? EN f+? EN f+? EN n.d EN n.d EN AZO dyes in textile: iis17a01 page 21 of 44

22 lab method 24X mark z(targ) 26X mark z(targ) sum of Xylidines mark z(targ) 2442 In house EN f+? EN f+? EN ex f+? EN C f+? EN f+? EN f+? EN f+? EN ex f+? EN R(0.01) f+? EN f+? EN f+? EN f+? EN f+? C,R(0.01) f+? EN f+? EN f+? EN C, f+? GB/T see remarks EN EN In house EN f+? EN f+? GB/T C f+? EN EN ex EN f+? EN n.d EN < GB/T f+? EN < 3 f-? <-6.01 n.d n.d f+? EN < EN f+? EN f+? EN f+? EN f+? EN f+? EN EN EN f+? In house < EN f+? EN EN f+? EN f+? EN EN f+? In house EN f+? EN < INH-7334 < 8 f-? <-5.71 < EN C C f+? EN < EN f+? EN C,R(0.01) C, f+? EN f+? EN C,R(0.01) C, f+? EN f+? EN EN f+? EN f+? EN EN < EN < EN f+? EN f+? AZO dyes in textile: iis17a01 page 22 of 44

23 lab method 24X mark z(targ) 26X mark z(targ) sum of Xylidines mark z(targ) 3154 EN f+? EN EN f+? EN f+? EN f+? EN f+? EN f+? EN f+? EN f+? EN EN n.d EN f+? EN n.d In house f+? EN f+? EN f+? EN f+? EN f+? ex EN C C EN f+? f+? EN EN f+? selected group *) normality OK OK n.a. OK n outliers 9+4ex 0 (105) (f+?) 0 mean (n) n.d. or < st.dev. (n) n.a R(calc.) n.a R(EN :12) **) n.a *) Selected group of test results from labs who had most likely a good separation of the Xylidine isomers and indentified 2,4-Xylidine correctly. **) Based on the average of five reproducibilities mentioned in table B.2 of test method EN :2012 Lab 2261 first reported: for 2,4-Xylidine Lab 2379 first reported for 2,4-Xylidine Lab 2456: test result for 2,4-Xylidine excluded as the same value was reported for 2,6-Xylidine; it was not clear whether the isomers were co-eluted and the reported value was ½ * the sum of the isomers? Lab 2467 first reported: for 2,4-Xylidine Lab 2477: test result for 2,4-Xylidine excluded as the same value was reported for 2,6-Xylidine; it was not clear whether the reported value was ½ * the sum of the isomers? Lab 2497 first reported: for 2,4-Xylidine Lab 2506 first reported: for 2,6-Xylidine Lab 2534 first reported: n.d. for 2,4-Xylidine Lab 2546: test result for 2,4-Xylidine excluded as the sum was reported of 2,4 and 2,6-Xylidine Lab 2730 first reported: n.d. for 2,4- and 2,6-Xylidine Lab 2767 first reported: n.d. for 2,4- and 2,6-Xylidine Lab 2775 first reported: for 2,4- and 0 for 2,6-Xylidine Lab 3222: test result for 2,4-Xylidine excluded as the sum was reported of 2,4 and 2,6-Xylidine Lab 3228 first reported: n.d. for 2,4- and 2,6-Xylidine AZO dyes in textile: iis17a01 page 23 of 44

24 ,4-Xylidine Kernel Density ,6-Xylidine ; most likely 2,5-Xylidine Kernel Density Sum Xylidines Kernel Density AZO dyes in textile: iis17a01 page 24 of 44

Results of Proficiency Test Colorants in textile (Allergenic & Carcinogenic) February 2016

Results of Proficiency Test Colorants in textile (Allergenic & Carcinogenic) February 2016 Results of Proficiency Test Colorants in textile (Allergenic & Carcinogenic) February 2016 Organised by: Author: Correctors: Report: Spijkenisse, the Netherlands dr. R.G. Visser ing. R.J. Starink & ing.

More information

Results of Proficiency Test Free Formaldehyde in textile October 2011

Results of Proficiency Test Free Formaldehyde in textile October 2011 Results of Proficiency Test Free Formaldehyde in textile October 2011 Organised by: Author: Correctors: Report: Spijkenisse, the Netherlands ing. L. Dijkstra dr. R. Visser & ing. N. Boelhouwer iis11a04

More information

Page 1 of 4 1. GENERAL INFORMATION: Product Description: Model Number: Model Difference: Brand Name: Applicant: Leather products (Pure leather & Hand

Page 1 of 4 1. GENERAL INFORMATION: Product Description: Model Number: Model Difference: Brand Name: Applicant: Leather products (Pure leather & Hand AZO TEST REPORT Commission Directive 2004/21/EC For Leather products (Pure leather & Hand made) Model: MPJ\DWBL\SWBL\DSQB\SQB\A20\NSJT\PTSJS\SMJ\YSK\DSLSZB\PSB\XRK\ LX\PH\PMB\SXBT\ZXBT\DWZB\MJ\ZL\WCY\TL\HP\TD\XQ\DNB\BJB\JSZ\PGJ

More information

FAPAS Report Sulphur Dioxide in Dried Apricot (water/fruit slurry) August-October 2015 NOT CONTROLLED WHEN PRINTED.

FAPAS Report Sulphur Dioxide in Dried Apricot (water/fruit slurry) August-October 2015 NOT CONTROLLED WHEN PRINTED. FAPAS Report 20120 Sulphur Dioxide in Dried Apricot (water/fruit slurry) August-October 2015 Page 1 of 16 PARTICIPANT LABORATORY NUMBER Participants can log in to FAPAS SecureWeb at any time to obtain

More information

TEST REPORT Page 1 of 12

TEST REPORT Page 1 of 12 TEST REPORT Page 1 of 12 REPORT NUMBER : APPLICANT NAME ADDRESS BUYER SAMPLE DESCRIPTION : Sample 1: Sample 2: TURT150097020 Ceren Kağıt ve Kırtasiye A.Ş. İOSB Ziya Gökalp Mh.Eski Turgut Özal Cd. Haseyad

More information

Euro Connection Ltd , Hunghom Commereial Centre Tower A, 39 Ma Tall Wai Road Hunghom, Kowloon Hong Kong. KiK Textilien und Non-Food GmbH

Euro Connection Ltd , Hunghom Commereial Centre Tower A, 39 Ma Tall Wai Road Hunghom, Kowloon Hong Kong. KiK Textilien und Non-Food GmbH A TUVRheinland Test Report No.: Client: Q00170613a 001 Euro Connection Ltd. 511-4, Hunghom Commereial Centre Tower A, 39 Ma Tall Wai Road Hunghom, Kowloon Hong Kong Page 1 of6 Buyer's name : Manufacturer's

More information

Intertek India Private Limited, G3, Ground Floor, Akruti Corporate Park, L.B.S. Marg, Kanjurmarg (West), Mumbai, Maharashtra

Intertek India Private Limited, G3, Ground Floor, Akruti Corporate Park, L.B.S. Marg, Kanjurmarg (West), Mumbai, Maharashtra Last Amended on 15.06.2015 Page 1 of 8 Range ing / I. TEXTILE & TEXTILE AUXILIARIES 1. Textile & Garment Colour Fastness to Washing ISO 105 C10: 2006 ISO 105 C06: 2010 AATCC 61: 2013 GB/T 3921: 2008 Colour

More information

Fapas Food Chemistry Proficiency Test Report Pesticide Residues in Rice. June-August Page 1 of 38

Fapas Food Chemistry Proficiency Test Report Pesticide Residues in Rice. June-August Page 1 of 38 Fapas Food Chemistry Proficiency Test Report 09110 Pesticide Residues in Rice N O T C O N TR O LL ED W H EN PR IN TE D June-August 2017 Page 1 of 38 PARTICIPANT LABORATORY NUMBER Participants can log in

More information

Restricted Substance List (RSL) Candles

Restricted Substance List (RSL) Candles Restricted Substance List (RSL) Candles Contents General... 3 Commitment... 4 Example... 5 Definitions... 6 Abbreviations... 6 Requirements all Candles... 7 Paraffin Wax... 7 Stearic Acid... 8 Beeswax...

More information

Technical Report. Collaborative Study 2017 on TSNA, ph, and Moisture (Oven Volatiles)

Technical Report. Collaborative Study 2017 on TSNA, ph, and Moisture (Oven Volatiles) Tobacco and Tobacco Products Analytes Sub-Group Technical Report Collaborative Study 2017 on TSNA, ph, and Moisture (Oven Volatiles) July 2017 Study Project Leaders: David Ericson, Ph.D., Swedish Match,

More information

Fapas Food Chemistry Proficiency Test Report Quality Indicators in Olive Oil. July-August Page 1 of 32

Fapas Food Chemistry Proficiency Test Report Quality Indicators in Olive Oil. July-August Page 1 of 32 Fapas Food Chemistry Proficiency Test Report 14176 Quality Indicators in Olive Oil N O T C O N TR O LL ED W H EN PR IN TE D July-August 2017 Page 1 of 32 PARTICIPANT LABORATORY NUMBER Participants can

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION ISO/TS 17503 First edition 2015-11-01 Statistical methods of uncertainty evaluation Guidance on evaluation of uncertainty using two-factor crossed designs Méthodes statistiques

More information

Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes

Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes Note: For the benefit of those who are not familiar with details of ISO 13528:2015 and with the underlying statistical principles

More information

Assessing Measurement System Variation

Assessing Measurement System Variation Example 1 Fuel Injector Nozzle Diameters Problem A manufacturer of fuel injector nozzles has installed a new digital measuring system. Investigators want to determine how well the new system measures the

More information

Sample Received Date : FEB 02, 2011 Additional Remark : Eco-friendly Water-base Ink and Heat Transfer consumables.

Sample Received Date : FEB 02, 2011 Additional Remark : Eco-friendly Water-base Ink and Heat Transfer consumables. Adidas Applicant: ARTDECO CREATIVE AND INVESTMENT Date: Feb 14, 2011 COMPANY LIMITED RM 15 5/F BLK B PARK FOOK IND BLDG 615 TAI NAN W ST LAI CHI KOK KLN HK Attn: MR KUDO AKIYA Conclusion of Report Summary

More information

USTER TESTER 5-S800 APPLICATION REPORT. Measurement of slub yarns Part 1 / Basics THE YARN INSPECTION SYSTEM. Sandra Edalat-Pour June 2007 SE 596

USTER TESTER 5-S800 APPLICATION REPORT. Measurement of slub yarns Part 1 / Basics THE YARN INSPECTION SYSTEM. Sandra Edalat-Pour June 2007 SE 596 USTER TESTER 5-S800 APPLICATION REPORT Measurement of slub yarns Part 1 / Basics THE YARN INSPECTION SYSTEM Sandra Edalat-Pour June 2007 SE 596 Copyright 2007 by Uster Technologies AG All rights reserved.

More information

Protocol for extracting a space-charge limited mobility benchmark from a single hole-only or electron-only current-voltage curve Version 2

Protocol for extracting a space-charge limited mobility benchmark from a single hole-only or electron-only current-voltage curve Version 2 NPL Report COM 1 Protocol for extracting a space-charge limited mobility benchmark from a single hole-only or electron-only current-voltage curve Version 2 James C Blakesley, Fernando A Castro, William

More information

Fapas Food Chemistry Proficiency Test Report Nitrate and Nitrite in Meat. October-November Page 1 of 22

Fapas Food Chemistry Proficiency Test Report Nitrate and Nitrite in Meat. October-November Page 1 of 22 Fapas Food Chemistry Proficiency Test Report 15123 Nitrate and Nitrite in Meat N O T C O N TR O LL ED W H EN PR IN TE D October-November 2017 Page 1 of 22 PARTICIPANT LABORATORY NUMBER Participants can

More information

Science Binder and Science Notebook. Discussions

Science Binder and Science Notebook. Discussions Lane Tech H. Physics (Joseph/Machaj 2016-2017) A. Science Binder Science Binder and Science Notebook Name: Period: Unit 1: Scientific Methods - Reference Materials The binder is the storage device for

More information

H&M GROUP CHEMICAL RESTRICTIONS 2018

H&M GROUP CHEMICAL RESTRICTIONS 2018 H&M GROUP CHEMICAL RESTRICTIONS 2018 RESTRICTED SUBSTANCES LIST (RSL) Candles Global Product Compliance Department Valid for all brands in the H&M Group. Contents General... 2 Commitment... 3 Example...

More information

AP Statistics Composition Book Review Chapters 1 2

AP Statistics Composition Book Review Chapters 1 2 AP Statistics Composition Book Review Chapters 1 2 Terms/vocabulary: Explain each term with in the STATISTICAL context. Bar Graph Bimodal Categorical Variable Density Curve Deviation Distribution Dotplot

More information

TPS 49 EDITION 2 JUNE 2009

TPS 49 EDITION 2 JUNE 2009 TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific

More information

Quality Systems, Accreditation and the Food Sector

Quality Systems, Accreditation and the Food Sector Presentation Outline Quality Systems, Accreditation and the Food Sector David Galsworthy Head of Quality Systems Team Central Science Laboratory York, UK My background The Quality Standards Accreditation

More information

Steady State Operating Curve

Steady State Operating Curve 1 Steady State Operating Curve University of Tennessee at Chattanooga Engineering 3280L Instructor: Dr. Jim Henry By: Fuchsia Team: Jonathan Brewster, Jonathan Wooten Date: February 1, 2013 2 Introduction

More information

Standard Test Method for Bow and Skew in Woven and Knitted Fabrics 1

Standard Test Method for Bow and Skew in Woven and Knitted Fabrics 1 Designation: D 3882 99 (Reapproved 2006) Standard Test Method for Bow and Skew in Woven and Knitted Fabrics 1 This standard is issued under the fixed designation D 3882; the number immediately following

More information

Tools and Methodologies for Pipework Inspection Data Analysis

Tools and Methodologies for Pipework Inspection Data Analysis 4th European-American Workshop on Reliability of NDE - We.2.A.4 Tools and Methodologies for Pipework Inspection Data Analysis Peter VAN DE CAMP, Fred HOEVE, Sieger TERPSTRA, Shell Global Solutions International,

More information

Why Should We Care? Everyone uses plotting But most people ignore or are unaware of simple principles Default plotting tools are not always the best

Why Should We Care? Everyone uses plotting But most people ignore or are unaware of simple principles Default plotting tools are not always the best Elementary Plots Why Should We Care? Everyone uses plotting But most people ignore or are unaware of simple principles Default plotting tools are not always the best More importantly, it is easy to lie

More information

Assessing Measurement System Variation

Assessing Measurement System Variation Assessing Measurement System Variation Example 1: Fuel Injector Nozzle Diameters Problem A manufacturer of fuel injector nozzles installs a new digital measuring system. Investigators want to determine

More information

Proficiency Test. QAiST testing of solar collectors and solar systems Final Report. May, 29 th 2012

Proficiency Test. QAiST testing of solar collectors and solar systems Final Report. May, 29 th 2012 Proficiency Test QAiST testing of solar collectors and solar systems 2010-2011 Final Report May, 29 th 2012 Institut für Eignungsprüfung GmbH Daimlerstraße 8, D-45770 Marl Organisation and performance:

More information

CORESTA RECOMMENDED METHOD N 47

CORESTA RECOMMENDED METHOD N 47 CORESTA RECOMMENDED METHOD N 47 CIGARS - SAMPLING (January 2000) 0. INTRODUCTION Existing national standards, rules, regulations and laws were taken into account when preparing this CORESTA Recommended

More information

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard 1. Abstract The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard Authors: Milen Todorakev, Jeff Gust Fluke Calibration. 6920 Seaway Blvd, Everett WA Tel:

More information

I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS

I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS Six Sigma Quality Concepts & Cases- Volume I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS Chapter 7 Measurement System Analysis Gage Repeatability & Reproducibility (Gage R&R)

More information

RECOMMENDATION ITU-R SM Method for measurements of radio noise

RECOMMENDATION ITU-R SM Method for measurements of radio noise Rec. ITU-R SM.1753 1 RECOMMENDATION ITU-R SM.1753 Method for measurements of radio noise (Question ITU-R 1/45) (2006) Scope For radio noise measurements there is a need to have a uniform, frequency-independent

More information

Leather clothes, gloves and belts Version 1.5 Certification Criteria

Leather clothes, gloves and belts Version 1.5 Certification Criteria Eco Mark Product Category No.144 Leather clothes, gloves and belts Version 1.5 Certification Criteria - Applicable Scope- Products having 60% (50% for gloves and mittens) or more of their outer surface

More information

Chrysotile, Chrysotile, 0. Amosite, Amosite, 0. Chrysotile, Chrysotile, 0. No Asbestos, No Asbestos, 0

Chrysotile, Chrysotile, 0. Amosite, Amosite, 0. Chrysotile, Chrysotile, 0. No Asbestos, No Asbestos, 0 HSL AIMS : Round Report https://xnet.hsl.gov.uk/aims/hsllabs/auaims_labs_roundresultsreportstd_v... von 1 23/2/217 7:43 Asbestos in Materials Individual Results : Round 61 : 61 AIMS Round 61 For Laboratory

More information

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES INTERNATIONAL TELECOMMUNICATION UNION CCITT X.21 THE INTERNATIONAL (09/92) TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE DATA COMMUNICATION NETWORK: INTERFACES INTERFACE BETWEEN DATA TERMINAL EQUIPMENT

More information

WG food contact materials

WG food contact materials WG food contact materials Monday 30 January European Commission DG SANTE, Unit E2 Food Processing Technologies and Novel Foods Food Contact Materials This presentation does not present any official views

More information

Design For Manufacturing. Design Documents. Gage R&R DFM

Design For Manufacturing. Design Documents. Gage R&R DFM rev.8. 1 Contents Purpose of the Abloy Part Approval Process is: 1. To provide the evidence that all customer engineering designs and required specifications are properly understood and fulfilled by manufacturing..

More information

Chapter 2 Distributed Consensus Estimation of Wireless Sensor Networks

Chapter 2 Distributed Consensus Estimation of Wireless Sensor Networks Chapter 2 Distributed Consensus Estimation of Wireless Sensor Networks Recently, consensus based distributed estimation has attracted considerable attention from various fields to estimate deterministic

More information

Mascot Distiller Hot Topics

Mascot Distiller Hot Topics Mascot Distiller Hot Topics 1 Mascot Distiller Hot Topics Quantitation FAQ from 2009 Label-free Quantitation Large Multi-File Projects Arg-Pro Conversion Automation This presentation will touch on some

More information

Technology: Lighting Units

Technology: Lighting Units Triple E Register Eligibility Criteria Category: Lighting Technology: Lighting Units Lighting units are products that are specifically designed to provide high efficiency interior or exterior illumination.

More information

TECHNICAL AND OPERATIONAL NOTE ON CHANGE MANAGEMENT OF GAMBLING TECHNICAL SYSTEMS AND APPROVAL OF THE SUBSTANTIAL CHANGES TO CRITICAL COMPONENTS.

TECHNICAL AND OPERATIONAL NOTE ON CHANGE MANAGEMENT OF GAMBLING TECHNICAL SYSTEMS AND APPROVAL OF THE SUBSTANTIAL CHANGES TO CRITICAL COMPONENTS. TECHNICAL AND OPERATIONAL NOTE ON CHANGE MANAGEMENT OF GAMBLING TECHNICAL SYSTEMS AND APPROVAL OF THE SUBSTANTIAL CHANGES TO CRITICAL COMPONENTS. 1. Document objective This note presents a help guide for

More information

C A R I B B E A N E X A M I N A T I O N S C O U N C I L REPORT ON CANDIDATES WORK IN THE SECONDARY EDUCATION CERTIFICATE EXAMINATION MAY/JUNE 2010

C A R I B B E A N E X A M I N A T I O N S C O U N C I L REPORT ON CANDIDATES WORK IN THE SECONDARY EDUCATION CERTIFICATE EXAMINATION MAY/JUNE 2010 C A R I B B E A N E X A M I N A T I O N S C O U N C I L REPORT ON CANDIDATES WORK IN THE SECONDARY EDUCATION CERTIFICATE EXAMINATION MAY/JUNE 2010 TECHNICAL DRAWING GENERAL PROFICIENCY Copyright 2010 Caribbean

More information

ARTICLE 11. Notification and recording of frequency assignments 1, 2, 3, 4, 5, 6, 7, 7bis (WRC-12)

ARTICLE 11. Notification and recording of frequency assignments 1, 2, 3, 4, 5, 6, 7, 7bis (WRC-12) ARTICLE 11 Notification and recording of frequency assignments 1, 2, 3, 4, 5, 6, 7, 7bis (WRC-12) 1 A.11.1 See also Appendices 30 and 30A as appropriate, for the notification and recording of: a) frequency

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Measurement House Contact: Mr David Gray Kingsway Tel: +44 (0)1792 588722 Fforestfach Fax: +44 (0)1792 582624 Swansea E-Mail: mail@haven.co.uk

More information

Nordic Ecolabelling of Candles

Nordic Ecolabelling of Candles rdic Ecolabelling of Candles Version 1.3 13 December 2007 30 June 2015 rdic Ecolabelling Content What is a rdic Ecolabelled candle? 3 Why choose the rdic Ecolabel? 3 What can carry the rdic Ecolabel? 4

More information

Laboratory 1: Uncertainty Analysis

Laboratory 1: Uncertainty Analysis University of Alabama Department of Physics and Astronomy PH101 / LeClair May 26, 2014 Laboratory 1: Uncertainty Analysis Hypothesis: A statistical analysis including both mean and standard deviation can

More information

PLC Papers Created For:

PLC Papers Created For: PLC Papers Created For: Year 11 Topic Practice Paper: Histograms Histograms with unequal class widths 1 Grade 6 Objective: Construct and interpret a histogram with unequal class widths (for grouped discrete

More information

Designated Institutes participating in the CIPM MRA

Designated Institutes participating in the CIPM MRA Designated Institutes participating in the CIPM MRA Expectations and nomination form Version 1.2 Contents 1. Introduction... 1 2. Designated Institute in Appendix A of the KCDB... 2 2.1. Designation of

More information

Type Approval JANUARY The electronic pdf version of this document found through is the officially binding version

Type Approval JANUARY The electronic pdf version of this document found through  is the officially binding version STANDARD FOR CERTIFICATION No. 1.2 Type Approval JANUARY 2013 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version The content of this service

More information

Anti cheating guidelines for Arbiters

Anti cheating guidelines for Arbiters Annex 19B Anti cheating guidelines for Arbiters (These guidelines shall be included in the subjects and will be taught in all Workshops, FIDE Arbiters Seminars and Courses for International and FIDE Arbiters).

More information

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 24. Optical Receivers-

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 24. Optical Receivers- FIBER OPTICS Prof. R.K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay Lecture: 24 Optical Receivers- Receiver Sensitivity Degradation Fiber Optics, Prof. R.K.

More information

REPORT ON THE EUROSTAT 2017 USER SATISFACTION SURVEY

REPORT ON THE EUROSTAT 2017 USER SATISFACTION SURVEY EUROPEAN COMMISSION EUROSTAT Directorate A: Cooperation in the European Statistical System; international cooperation; resources Unit A2: Strategy and Planning REPORT ON THE EUROSTAT 2017 USER SATISFACTION

More information

I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS

I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS Six Sigma Quality Concepts & Cases- Volume I STATISTICAL TOOLS IN SIX SIGMA DMAIC PROCESS WITH MINITAB APPLICATIONS Chapter 7 Measurement System Analysis Gage Repeatability & Reproducibility (Gage R&R)

More information

Examiner and moderator FAQ

Examiner and moderator FAQ Examiner and moderator FAQ 1 Contacts and Support... 1 1.1 How do I contact AQA as an examiner/moderator?... 1 1.2 What support will there be if I experience technical or other problems whilst marking

More information

UPDATES to the. Rules of Procedure. (Edition of 1998) approved by the Radio Regulations Board. Contents

UPDATES to the. Rules of Procedure. (Edition of 1998) approved by the Radio Regulations Board. Contents UPDATES to the Rules of Procedure (Edition of 1998) approved by the Radio Regulations Board Revision (1) (Circular No.) Date Part ARS Pages to be removed Pages to be inserted 1 June 1999 A1 ARS5 15-18

More information

EXPERIMENTAL ERROR AND DATA ANALYSIS

EXPERIMENTAL ERROR AND DATA ANALYSIS EXPERIMENTAL ERROR AND DATA ANALYSIS 1. INTRODUCTION: Laboratory experiments involve taking measurements of physical quantities. No measurement of any physical quantity is ever perfectly accurate, except

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 3, Watt House Innovation Centre Pensnett Estate Kingswinford West Midlands DY6 7YD Contact: Mr A P Walker Tel: +44 (0)1384 401132 Fax: +44 (0)1384 400754 E-Mail: mail@quasartronics.com Website: www.quasartronics.com

More information

University of Tennessee at. Chattanooga

University of Tennessee at. Chattanooga University of Tennessee at Chattanooga Step Response Engineering 329 By Gold Team: Jason Price Jered Swartz Simon Ionashku 2-3- 2 INTRODUCTION: The purpose of the experiments was to investigate and understand

More information

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide 1 NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT Physics 253 Fundamental Physics Mechanic, September 9, 2010 Lab #2 Plotting with Excel: The Air Slide Lab Write-up Due: Thurs., September 16, 2010 Place

More information

USTER ZWEIGLE TWIST TESTER 5

USTER ZWEIGLE TWIST TESTER 5 USTER ZWEIGLE TWIST TESTER 5 APPLICATION REPORT Measurement and significance of yarn twist THE YARN PROCESS CONTROL SYSTEM R. Furter, S. Meier September 2009 SE 631 Copyright 2009 by Uster Technologies

More information

1.1 Displaying Distributions with Graphs, Continued

1.1 Displaying Distributions with Graphs, Continued 1.1 Displaying Distributions with Graphs, Continued Ulrich Hoensch Thursday, January 10, 2013 Histograms Constructing a frequency table involves breaking the range of values of a quantitative variable

More information

Why Should We Care? More importantly, it is easy to lie or deceive people with bad plots

Why Should We Care? More importantly, it is easy to lie or deceive people with bad plots Elementary Plots Why Should We Care? Everyone uses plotting But most people ignore or are unaware of simple principles Default plotting tools (or default settings) are not always the best More importantly,

More information

GENERAL DESCRIPTION OF THE CMC SERVICES

GENERAL DESCRIPTION OF THE CMC SERVICES STANDARD FOR CERTIFICATION No.1.1 GENERAL DESCRIPTION OF THE CMC SERVICES MAY 2007 FOREWORD (DNV) is an autonomous and independent foundation with the objectives of safeguarding life, property and the

More information

Understanding Apparent Increasing Random Jitter with Increasing PRBS Test Pattern Lengths

Understanding Apparent Increasing Random Jitter with Increasing PRBS Test Pattern Lengths JANUARY 28-31, 2013 SANTA CLARA CONVENTION CENTER Understanding Apparent Increasing Random Jitter with Increasing PRBS Test Pattern Lengths 9-WP6 Dr. Martin Miller The Trend and the Concern The demand

More information

CHAPTER 13A. Normal Distributions

CHAPTER 13A. Normal Distributions CHAPTER 13A Normal Distributions SO FAR We always want to plot our data. We make a graph, usually a histogram or a stemplot. We want to look for an overall pattern (shape, center, spread) and for any striking

More information

An Efficient Color Image Segmentation using Edge Detection and Thresholding Methods

An Efficient Color Image Segmentation using Edge Detection and Thresholding Methods 19 An Efficient Color Image Segmentation using Edge Detection and Thresholding Methods T.Arunachalam* Post Graduate Student, P.G. Dept. of Computer Science, Govt Arts College, Melur - 625 106 Email-Arunac682@gmail.com

More information

Comparison of squareness measurements

Comparison of squareness measurements Slovenský metrologický ústav Slovak Institute of Metrology Slowakisches Institut für Metrologie EUROMET Supplementary Comparison #910 Comparison of squareness measurements Final Report Jiri Mokros, SMU,

More information

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope Product Note Table of Contents Introduction........................ 1 Jitter Fundamentals................. 1 Jitter Measurement Techniques......

More information

Gage Repeatability and Reproducibility (R&R) Studies. An Introduction to Measurement System Analysis (MSA)

Gage Repeatability and Reproducibility (R&R) Studies. An Introduction to Measurement System Analysis (MSA) Gage Repeatability and Reproducibility (R&R) Studies An Introduction to Measurement System Analysis (MSA) Agenda Importance of data What is MSA? Measurement Error Sources of Variation Precision (Resolution,

More information

Appendix III Graphs in the Introductory Physics Laboratory

Appendix III Graphs in the Introductory Physics Laboratory Appendix III Graphs in the Introductory Physics Laboratory 1. Introduction One of the purposes of the introductory physics laboratory is to train the student in the presentation and analysis of experimental

More information

IS LIMITED REGISTRATION OF IRON OXIDE PELLETS UNDER REACH AN OPTION?

IS LIMITED REGISTRATION OF IRON OXIDE PELLETS UNDER REACH AN OPTION? Position paper (author: Rob Versfeld, Corus Staal BV, nominated lead registrant) IS LIMITED REGISTRATION OF IRON OXIDE PELLETS UNDER REACH AN OPTION? Do Iron Oxide Pellets [Einecs number 265-996-3] fall

More information

PPAP 3rd Edition Check List

PPAP 3rd Edition Check List PPAP 3rd Edition Check List Supplier: PPAPKIT_F01 Rev. A (May_03) Date: Submission Level: Part #: Eng. Chg. Level: Reviewed By: Yes No N/A Comments 1. Design Records / Drawings 2. Eng. Chg. Documents On

More information

Fiscal 2007 Environmental Technology Verification Pilot Program Implementation Guidelines

Fiscal 2007 Environmental Technology Verification Pilot Program Implementation Guidelines Fifth Edition Fiscal 2007 Environmental Technology Verification Pilot Program Implementation Guidelines April 2007 Ministry of the Environment, Japan First Edition: June 2003 Second Edition: May 2004 Third

More information

Official Journal of the European Union

Official Journal of the European Union 26.1.2018 L 22/3 COMMISSION DELEGATED REGULATION (EU) 2018/122 of 20 October 2017 amending Annexes I, II, VI, VIII and IX to Regulation (EU) No 1007/2011 of the European Parliament and of the Council on

More information

Test Report

Test Report Test Report 20103677301 based on: IEC 61162-2 first edition 1998-09 (Clause 8.4.1 only) AIS Class A and Inland Transponder CNS Systems VDL 6000 Page: 2 of 31 Contents MAIN MODULE... 3 1 INTRODUCTION...

More information

FAPAS Report Pesticide Residues in Green Tea. January February Page 1 of 32

FAPAS Report Pesticide Residues in Green Tea. January February Page 1 of 32 FAPAS Report 19162 Pesticide Residues in Green Tea N O T C O N TR O LL ED W H EN PR IN TE D January February 2014 Page 1 of 32 PARTICIPANT LABORATORY NUMBER Participants can log in to FAPAS SecureWeb at

More information

Protocols. Graphical programming for Icy. a.k.a. programming, for the rest of us

Protocols. Graphical programming for Icy. a.k.a. programming, for the rest of us Protocols Graphical programming for Icy a.k.a. programming, for the rest of us Foreword: Reproducible Research Quote: "Results aren't much if they can t be reproduced!" (your boss, your reviewers, your

More information

Steady State Operating Curve

Steady State Operating Curve Steady State Operating Curve By Lanze Berry University of Tennessee at Chattanooga Engineering 3280L Blue Team (Khanh Nguyen, Justin Cartwright) Course: ENGR 3280L Section: 001 Date: September 4, 2012

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

SAE AE-2 Lightning Committee White Paper

SAE AE-2 Lightning Committee White Paper SAE AE-2 Lightning Committee White Paper Recommended Camera Calibration and Image Evaluation Methods for Detection of Ignition Sources Rev. NEW January 2018 1 Table of Contents Executive Summary... 3 1.

More information

LABORATORY 3 v1 CIRCUIT ELEMENTS

LABORATORY 3 v1 CIRCUIT ELEMENTS University of California Berkeley Department of Electrical Engineering and Computer Sciences EECS 100, Professor Bernhard Boser LABORATORY 3 v1 CIRCUIT ELEMENTS The purpose of this laboratory is to familiarize

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK CET Structures Ltd. trading as CET Calibration M1 Commerce Park Markham Lane Duckmanton Chesterfield S44 5HS Contact: Mr Chris Locke Tel: +44 (0)1246 828318 Fax: +44 (0)1246 828319 E-Mail: chris.locke@cetcalibration.com

More information

MARK SCHEME for the October/November 2010 question paper for the guidance of teachers 9701 CHEMISTRY

MARK SCHEME for the October/November 2010 question paper for the guidance of teachers 9701 CHEMISTRY UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS GCE Advanced Subsidiary Level and GCE Advanced Level MARK SCHEME for the October/November 2010 question paper for the guidance of teachers 9701 CHEMISTRY

More information

THE NATIONAL LITTER POLLUTION MONITORING SYSTEM LITTER MONITORING BODY 2017 AUDIT REPORT

THE NATIONAL LITTER POLLUTION MONITORING SYSTEM LITTER MONITORING BODY 2017 AUDIT REPORT THE NATIONAL LITTER POLLUTION MONITORING SYSTEM LITTER MONITORING BODY 2017 AUDIT REPORT Prepared for: The Department of Communications, Climate Action and Environment 29-31 Adelaide Road Dublin 2 D02

More information

SEI Certification Program Manual

SEI Certification Program Manual Safety Equipment Institute SEI Certification Program Manual Section 29: Industrial Protective Clothing and Equipment Program 0 of 6 SEI Certification Program Manual Section 29: Industrial Protective Clothing

More information

Lab/Project Error Control Coding using LDPC Codes and HARQ

Lab/Project Error Control Coding using LDPC Codes and HARQ Linköping University Campus Norrköping Department of Science and Technology Erik Bergfeldt TNE066 Telecommunications Lab/Project Error Control Coding using LDPC Codes and HARQ Error control coding is an

More information

Female Height. Height (inches)

Female Height. Height (inches) Math 111 Normal distribution NAME: Consider the histogram detailing female height. The mean is 6 and the standard deviation is 2.. We will use it to introduce and practice the ideas of normal distributions.

More information

Using Figures - The Basics

Using Figures - The Basics Using Figures - The Basics by David Caprette, Rice University OVERVIEW To be useful, the results of a scientific investigation or technical project must be communicated to others in the form of an oral

More information

!"#$%&'("&)*("*+,)-(#'.*/$'-0%$1$"&-!!!"#$%&'(!"!!"#$%"&&'()*+*!

!#$%&'(&)*(*+,)-(#'.*/$'-0%$1$&-!!!#$%&'(!!!#$%&&'()*+*! !"#$%&'("&)*("*+,)-(#'.*/$'-0%$1$"&-!!!"#$%&'(!"!!"#$%"&&'()*+*! In this Module, we will consider dice. Although people have been gambling with dice and related apparatus since at least 3500 BCE, amazingly

More information

ERC Recommendation 54-01

ERC Recommendation 54-01 ERC Recommendation 54-01 Method of measuring the maximum frequency deviation of FM broadcast emissions in the band 87.5 to 108 MHz at monitoring stations Approved May 1998 Amended 13 February 2015 Amended

More information

New Certified Reference Materials for Chromatography

New Certified Reference Materials for Chromatography New Certified Reference Materials for Chromatography Dr. Frank Michel Frank.michel@sial.com sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All rights reserved. Use of Certified Reference Materials

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Name: Partners: Statistics. Review 2 Version A

Name: Partners: Statistics. Review 2 Version A Name: Partners: Statistics Date: Review 2 Version A [A] Circle whether each statement is true or false. 1. Home prices in Scotts Valley are skewed right. 2. A circle graph can always be remade into a bar

More information

This page intentionally left blank

This page intentionally left blank Appendix E Labs This page intentionally left blank Dice Lab (Worksheet) Objectives: 1. Learn how to calculate basic probabilities of dice. 2. Understand how theoretical probabilities explain experimental

More information

UT-ONE Accuracy with External Standards

UT-ONE Accuracy with External Standards UT-ONE Accuracy with External Standards by Valentin Batagelj Batemika UT-ONE is a three-channel benchtop thermometer readout, which by itself provides excellent accuracy in precise temperature measurements

More information

CCG 360 o Stakeholder Survey

CCG 360 o Stakeholder Survey July 2017 CCG 360 o Stakeholder Survey National report NHS England Publications Gateway Reference: 06878 Ipsos 16-072895-01 Version 1 Internal Use Only MORI This Terms work was and carried Conditions out

More information

MEMORANDUM FORT LEWIS AGREED ORDER RI DEMONSTRATION OF METHOD APPLICABILITY SAMPLING AND ANALYSIS PLAN ADDENDUM FORMER SMALL ARMS RANGES

MEMORANDUM FORT LEWIS AGREED ORDER RI DEMONSTRATION OF METHOD APPLICABILITY SAMPLING AND ANALYSIS PLAN ADDENDUM FORMER SMALL ARMS RANGES MEMORANDUM FORT LEWIS AGREED ORDER RI DEMONSTRATION OF METHOD APPLICABILITY SAMPLING AND ANALYSIS PLAN ADDENDUM FORMER SMALL ARMS RANGES 1.0 INTRODUCTION This memorandum present the results of the Demonstration

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD ANSI CGATS.5-2003 Supplement - 2005 AMERICAN NATIONAL STANDARD Graphic technology Graphic arts transmission densitometry Terminology, equations, image elements and procedures Supplement SECRETARIAT NPES

More information

Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations. Recommendation ITU-R SM.

Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations. Recommendation ITU-R SM. Recommendation ITU-R SM.1268-4 (11/217) Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations SM Series Spectrum management ii Rec. ITU-R SM.1268-4 Foreword

More information