Accurately capture signals with Smart Noise Reduction
|
|
- Carol Ramsey
- 5 years ago
- Views:
Transcription
1 Smart Fiber Amplifier Units ENX-FA Long Range for Small Object Detection Rapid analysis with dual digital display White characters on black display for high visibility Reduced set-up time with push button teach Selectable power and response times to match your application Tailor machine functions with timer options Minimize debris build-up and LED deterioration for longer life Network compatibility for data management CSM_ENX-FA_E9I-E-0 For the most recent information on ls that have been certified for safety standards, refer to your OMR website. Refer to the Safety Precautions on page 7. Accurately capture signals with Smart Noise Reduction.5 Times Powerful coupling module Without GIGA RAY With GIGA RAY By increasing the number of samples and the threshold margin, the influences of noise are greatly reduced., high precision The lens and reflector focus light beams for uniform brightness. Adjust the light intesity to accurately detect fast-moving workpieces. A response time of 0µ s can be achieved. in highspeed. Ordering Information Fiber Amplifier Units (Dimensions pages 9 and 0) Type Connecting Appearance Inputs/outputs NPN output PNP output Standard ls Pre-wired ( m) output ENX-FA M ENX-FA-5 M CE NEW * ENX-FA4 M --- Wire-saving Connector output ENX-FA6 ENX-FA8 Pre-wired ( m) outputs + input ENX-FA M ENX-FA5 M Advanced ls Wire-saving Connector output + input ENX-FA7 ENX-FA9 outputs ENX-FA7TW ENX-FA9TW output + input ENX-FA4 ENX-FA54 M8 Connector outputs --- ENX-FA54TW *. This type can prevent mutual interference for two units in the SHS.
2 Type Connecting Appearance Inputs/outputs NPN output PNP output Infrared ls Pre-wired ( m) output ENX-FAH M CE ENX-FAH4 M CE NEW NEW Wire-saving Connector output ENX-FAH6 CE ENX-FAH8 CE NEW NEW Analog output ls Pre-wired ( m) outputs ENX-FAAN M CE ENX-FA4AN M CE NEW NEW for Sensor Communications Unit * Connector for Sensor Communications Unit *. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network. Accessories (Sold Separately) Wire-saving Connectors (Required for ls for Wire-saving Connectors.) (Dimensions page ) Connectors are not provided with the Fiber Amplifier Unit and mu st be ordered separately. Note: Protective stickers are provide d. --- ENX-FA0 ENX-FAH0 CE Type Appearance Cable length No. of conductors Applicable Fiber Amplifier Units NEW Master Connector Slave Connector 4 EX-CN EX-CN ENX-FA7 ENX-FA7TW ENX-FA9 ENX-FA9TW m Master Connector Slave Connector EX-CN EX-CN ENX-FA6 ENX-FA8 Sensor I/O Connectors (Required for ls for M8 Connectors.) (Dimensions page ) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. Size Cable Appearance Cable type m XSF-M4-40-A Straight 5m XSF-M4-405-A M8 Standard cable 4-wire m XSF-M4-40-A L-shaped 5m XSF-M4-405-A
3 Mounting Bracket (Dimensions page ) A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. Appearance Quantity Related Products Sensor Communications Units Type Appearance E9-L4 Sensor Communications Unit for EtherCAT ENW-ECT DIN Track (Dimensions page ) A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. Appearance Type Quantity Sensor Communications Unit for CompoNet ENW-CRT * Shallow type, total length: m Shallow type, total length: 0.5 m PFP-00N PFP-50N Sensor Communications Unit for CC-Link ENW-CCL Deep type, total length: m PFP-00N End Plate (Dimensions page ) Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required. Appearance Quantity PFP-M Cover Attach these Covers to Amplifier Units. Order a Cover when required, e.g., if you lose the covers. Appearance Quantity E9-G5 FOR ENX-FA NEW Distributed Sensor Unit * ENW-DS Refer to your OMR website for details. *. Only ENX-FA0 can be connected to ENW-CRT. *. The Distributed Sensor Unit can be connected to any of the Sensor Communications Units. EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. CompoNet is a registered trademark of the ODVA. CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.
4 Ratings and Specifications Standard ls/ Advanced ls/ Infrared ls Item Giga-power 0 (GIGA) *. This type can prevent mutual interference for two units in the SHS. *. At Power supply voltage of 0 to 0 VDC Standard s: Normal : 990 mw max. (Current consumption: ma max. at 0 VDC, 65 ma max. at 0 VDC) Eco function : 780 mw max. (Current consumption: 6 ma max. at 0 VDC, 4 ma max. at 0 VDC) Eco function LO : 840 mw max. (Current consumption: 8 ma max. at 0 VDC, 45 ma max. at 0 VDC) Advanced s: Normal :,00 mw max. (Current consumption: 4 ma max. at 0 VDC, 67 ma max. at 0 VDC) Eco function : 80 mw max. (Current consumption: 7 ma max. at 0 VDC, 44 ma max. at 0 VDC) Eco function LO : 870 mw max. (Current consumption: 9 ma max. at 0 VDC, 48 ma max. at 0 VDC) Infrared ls: Normal :,60 mw max. (Current consumption: 4 ma max. at 0 VDC, 80 ma max. at 0 VDC) Eco function :,050 mw max. (Current consumption: 5 ma max. at 0 VDC, 60 ma max. at 0 VDC) Eco function LO :,40 mw max. (Current consumption: 8 ma max. at 0 VDC, 70 ma max. at 0 VDC) *. The following details apply to the input. *-.Input time is 5 ms ()/() only when (in tune) or (in PtUn) input is selected. *4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of ENX and ENC. Check the mutual interference prevention unit count and response speed of each l. ENX-FA Type Standard ls Advanced ls Infrared ls NPN output ENX-FA ENX-FA6 ENX-FA-5 * ENX-FA ENX-FA7 ENX-FA7TW ENX-FA4 --- ENX-FAH ENX-FAH6 PNP output ENX-FA4 ENX-FA8 --- ENX-FA5 ENX-FA9 ENX-FA9TW ENX-FA54 ENX-FA54TW ENX-FAH4 ENX-FAH8 Connecting Pre-wired Wire-saving Connector Pre-wired Pre-wired Wire-saving Connector M8 Connector Pre-wired Wire-saving Connector Inputs/ s output outputs output outputs output outputs outputs outputs External inputs --- input input --- input Light source (wavelength) Red, 4-element LED (65 nm) Infrared LED (870nm) Power supply voltage 0 to 0 VDC, including 0% ripple (p-p) At Power supply voltage of 4 VDC Standard s: Normal : 840 mw max. (Current consumption at 5 ma max.) Eco function : 650 mw max. (Current consumption at 7 ma max.) Eco function LO : 750 mw max. (Current consumption at ma max.) Advanced s or for Sensor Communications Unit: Power consumption * Normal : 90 mw max. (Current consumption at 8 ma max.) Eco function : 680 mw max. (Current consumption at 8 ma max.) Eco function LO : 800 mw max. (Current consumption at ma max.) Infrared ls: Normal : 080 mw max. (Current consumption at 45 ma max.) Eco function : 90 mw max. (Current consumption at 8 ma max.) Eco function LO : 00 mw max. (Current consumption at 4 ma max.) power supply voltage: 0 VDC max., open-collector output (depends on the NPN/PNP output format) current: Groups of to Amplifier Units: 00 ma max., Groups of 4 to 0 Amplifier Units: 0 ma max. Control output Residual voltage: At load current of less than 0 ma: V max. At load current of 0 to 00 ma: V max. current: 0. ma max. External inputs --- Refer to *. --- Refer to *. --- Indicators Protection circuits (SHS) Response time 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator, L/D indicator, ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on ls with outputs) Power supply reverse polarity protection, output short-circuit protection, and output reve rse polarity protection or reset for l with output: 0 μs (Super High Speed (SHS) of ENX-FA-5 is 60 μs each), with outputs: μs or reset: 50 μs (HS) Standard or reset: ms (Stnd) Giga-power or reset: 6 ms (GIGA) Smart Tuning (-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment Sensitivity adjustment Maximum connectable Units 0 No. of Units for mutual interference prevention *4 NPN PNP (SHS) (HS) Standard (Stnd) 0 Note: units when the detection is set to Super High Speed (SHS), and for other ls, the mutual interference prevention function is disabled. 0 0 Contact input (relay or switch) Non-contact input () Input time *- : Shorted to 0 V (Sourcing current: ma max.). : Open or shorted to Vcc. : Shorted to Vcc (Sinking current: ma max.). : Open or shorted to 0 V. :.5 V max. (Sourcing current: ma max.) : Vcc.5 V to Vcc (Leakage current: 0. ma max.) : Vcc.5 V to Vcc (Sinking current: ma max.) :.5 V max. (Leakage current: 0. ma max.) : 9 ms min. : 0 ms min. 4
5 Item Functions Type Standard ls Advanced ls Infrared ls NPN output ENX-FA ENX-FA6 ENX-FA-5 * ENX-FA ENX-FA7 ENX-FA7TW ENX-FA4 --- ENX-FAH ENX-FAH6 PNP output ENX-FA4 ENX-FA8 --- ENX-FA5 ENX-FA9 ENX-FA9TW ENX-FA54 ENX-FA54TW ENX-FAH4 ENX-FAH8 Connectin g Pre-wired Wire-saving Connector *5. The bank is not reset by the user reset function or saved by the user save function. *6. Eco LO is supported for Amplifier Units manufactured in July 04 or later. *7. When the number of connected units is or more, the ambient temperature is less than 50 C. Pre-wired Pre-wired Wire-saving Connector M8 Connector Pre-wired Wire-saving Connector Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, -delay, -delay, one-shot, or -delay + -delay timer: to 9,999 ms Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings *5 Select from initial reset (factory defaults) or user reset (saved settings). Eco *6 Select from (digital display lit), Eco (digital display not lit), and Eco LO (digital display dimmed). Bank switching Select from banks to 4. Power tuning Select from, or Execution on power-up. Select from or. Select from normal detection, area detection or differential detection. Select from normal detection or area detection. --- External input --- Select from normal detection, alarm output, error output or differential detection. --- Select from input, tuning, power tuning, emission, zero reset, or bank switching. Select from normal detection, alarm output ---, error output or differential detection. Select from input, tuning, power tuning, --- emission, zero reset, or bank switching. Select from normal detection, alarm output, error output or differential detection. Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. Ambient illumination (Receiver side) Incandescent lamp: 0,000 lx max., Sunlight: 0,000 lx max. Ambient temperature range *7 Ambient humidity range Altitude Installation environment Insulation resistance Dielectric strength Vibration resistance (destruction) Shock resistance (destruction) Weight (packed state/ Sensor only) Case Materials Cover Cable Accessories Operating: Groups of or Amplifier Units: 5 to 55 C, Groups of to 0 Amplifier Units: 5 to 50 C, Groups of to 6 Amplifier Units: 5 to 45 C, Groups of 7 to 0 Amplifier Units: 5 to 40 C Storage: 0 to 70 C (with no icing or condensation) Operating and storage: 5 to 85% (with no condensation) within the surrounding air temperature range shown above,000 m max. Pollution degree 0 MΩ min. (at 500 VDC),000 VAC at 50/60 Hz for min 0 to 55 Hz with a.5-mm double amplitude for hours each in X, Y, and Z directions 500 m/s for times each in X, Y, and Z directions Approx. 5 g/ approx. 75 g Approx. 60g/ approx. 0g Polycarbonate (PC) Polycarbonate (PC) PVC Instruction Manual Approx. 5 g/ approx. 75 g Approx. 5 g/ approx. 75 g Approx. 60g/ approx. 0g Approx. 65 g/ approx. 5 g Approx. 5 g/ approx. 75 g Approx. 60g/ approx. 0g 5
6 Analog output ls/ for Sensor Communications Unit Type Analog output ls for Sensor Communications Unit NPN output ENX-FAAN ENX-FA0 ENX-FAH0 PNP output ENX-FA4AN Item Connecting Pre-wired Connector for Sensor Communications Unit Inputs/ s outputs outputs External inputs * --- * Light source (wavelength) Red, 4-element LED (65 nm) Infrared LED (870nm) Power supply voltage 0 to 0 VDC, including 0% ripple (p-p) Supplied from the connector through the communication units. Power consumption * Control output Analog output Indicators Protection circuits Control output Response time Super-high-speed (SHS) At Power supply voltage of 4 VDC Normal : 960 mw max. (Current consumption at 40 ma max.) Eco function : 770 mw max. (Current consumption at ma max.) Eco function LO : 870 mw max. (Current consumption at 6 ma max.) power supply voltage: 0 VDC max., open-collector output (depends on the NPN/PNP output format) current: Groups of to Amplifier Units: 00 ma max., Groups of 4 to 0 Amplifier Units: 0 ma max. Residual voltage: ( At load current of less than 0 ma: V max. ) At load current of 0 to 00 ma: V max. current: 0. ma max. Voltage output: -5 VDC (0 kω or more connected load), temperature characteristics: 0.% F.S. / C At Power supply voltage of 4 VDC Normal : 90 mw max. (Current consumption at 8 ma max.) Eco function : 680 mw max. (Current consumption at 8 ma max.) Eco function LO : 800 mw max. (Current consumption at ma max.) *. Two sensor outputs are allocated in the programmable logic controller PLC I/O table. PLC operation via Communications Unit enables reading detected values and changing settings. *. At Power supply voltage of 0 to 0 VDC Analog output ls: Normal :,080 mw max. (Current consumption: 6 ma max. at 0 VDC, 75 ma max. at 0 VDC) Eco function : 840 mw max. (Current consumption: 8 ma max. at 0 VDC, 55 ma max. at 0 VDC) Eco function LO : 960 mw max. (Current consumption: ma max. at 0 VDC, 65 ma max. at 0 VDC) *. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of ENX and ENC. Check the mutual interference prevention unit count and response speed of each l At Power supply voltage of 4 VDC Normal :,080 mw max. (Current consumption at 45 ma max.) Eco function : 90 mw max. (Current consumption at 8 ma max.) Eco function LO :,00 mw max. (Current consumption at 4 ma max.) 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator, L/D indicator, ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on ls with outputs) Power supply reverse polarity protection, output short-circuit Power supply reverse polarity protection and output short-circuit protection protection, and output reve rse polarity protection or reset: 80 μs or reset: μs (HS) or reset: 50μs or reset: 50 μs Standard (Stnd) or reset: ms or reset: ms Giga-power (GIGA) or reset: 6 ms or reset: 6 ms Sensitivity adjustment Smart Tuning (-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, percentage tuning ( 99% to 99%)) or manual adjustment With ENW-ECT: 0 units (When connected to an OMR NJ-series Controller.) Maximum connectable Units 0 With ENW-CRT: 6 units (Note: ENX-FAH0 can not be connected.) With ENW-CCL: 6 units No. of Units for mutual interference prevention * Super-high-speed (SHS) (HS) 0 Standard (Stnd) 0 Giga-power (GIGA) 0 (The mutual interference prevention function is disabled if the detection is set to super-high-speed.) 0 6
7 Item Functions NPN output PNP output Type Analog output ls for Sensor Communications Unit ENX-FAAN ENX-FA4AN *4. The bank is not reset by the user reset function or saved by the user save function. *5. When the number of connected units is or more, the ambient temperature is less than 50 C. ENX-FA0 ENX-FAH0 Connecting Pre-wired Connector for Sensor Communications Unit Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, -delay, -delay, one-shot, or -delay + -delay timer: to 9,999 ms Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings *4 Select from initial reset (factory defaults) or user reset (saved settings). Eco Select from (digital display lit), Eco (digital display not lit), and Eco LO (digital display dimmed). Bank switching Select from banks to 4. Power tuning Select from or. Select from normal detection or area detection. Select from Analog scaling or Analog offset. Select from normal detection, alarm output, error output or differential detection (ENX-FA0 only). Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. Ambient illumination (Receiver side) Incandescent lamp: 0,000 lx max., Sunlight: 0,000 lx max. Ambient temperature range *5 Operating: Groups of or Amplifier Units: 5 to 55 C, Groups of to 0 Amplifier Units: 5 to 50 C, Groups of to 6 Amplifier Units: 5 to 45 C, Groups of 7 to 0 Amplifier Units: 5 to 40 C Storage: 0 to 70 C (with no icing or condensation) Operating: Groups of or Amplifier Units: 0 to 55 C, Groups of to 0 Amplifier Units: 0 to 50 C, Groups of to 6 Amplifier Units: 0 to 45 C, Groups of 7 to 0 Amplifier Units: 0 to 40 C Storage: 0 to 70 C (with no icing or condensation) Ambient humidity range Operating and storage: 5 to 85% (with no condensation) within the surrounding air temperature range shown above Altitude,000 m max. Installation environment Pollution degree Insulation resistance 0 MΩ min. (at 500 VDC) Dielectric strength,000 VAC at 50/60 Hz for min Vibration resistance (destruction) 0 to 55 Hz with a.5-mm double amplitude for hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s for times each in X, Y, and Z directions 50 m/s for times each in X, Y, and Z directions Weight (packed state/sensor only) Approx. 5 g/approx. 75 g Approx. 65 g/approx. 5 g Approx. 65 g/approx. 5 g Case Polycarbonate (PC) Materials Cover Polycarbonate (PC) Cable PVC Accessories Instruction Manual 7
8 Distances Standard ls/ Advanced ls/ Analog output ls Threaded s Reflective direction *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. Cylindrical s Reflective Right-angle Straight Right-angle Straight Size dia. Size M4 M Giga distance (mm) Standard ENX-FA E-TN M,000,500, E-LTN M 4,000 * 4,000 *, E-TR M,000,500, E-LT M 4,000 * 4,000 * 4,000 *,080 E-LTR M 4,000 * 4,000 *, E-CN M E-CN M M4 E-DN M, M6 M E-CN M, E-LDN M, E-DR M E-C M E-CM M M4 E-DR M M6 direction E-DR M, E-CC00 M, E-LD M, E-LDR M, Giga distance (mm) Standard E-TR M dia. E-TB M, dia..5 dia..5 dia dia. dia. dia dia. E-TR M,000,500, Side-view E-T4LR M, E-DB M E-D4M M E-DR M E-DB M E-DL M, E-D M Flat s Reflective direction Giga distance (mm) Standard E-T5XR M,000,500, Side-view Flat-view E-T5YR M E-T5ZR M, E-D5XR M, Side-view Flat-view E-D5YR M E-D5ZR M
9 Sleeve s Reflective direction Side-view Side-view Giga distance (mm) Standard E-T4R M E-T4E M E-T M E-T-S M E-TC00BR M,000,500, E-D4R M E-D4-S M E-D4M M E-D M 9 6 E-D M E-D-S 0.5M E-D-S 0.5M E-DC00F4R M E-D-S M E-D-S M E-DC00BR M, E-D5-S M Small-spot, Reflective s Type Spot diameter distance (mm) Center s distance (mm) Giga Standard Variable spot 0. to 0.6 dia. 6 to 5 E-C4 M + E9-FA Spot diameter of 0. to 0.6 mm at 6 to 5 mm. 0. to.6 dia. 0 to 0 E-C4 M + E9-F7 Spot diameter of 0. to.6 mm at 0 to 0 mm. Parallel light 4 dia. 0 to 0 E-C M + E9-FC E-CN M + E9-FC Spot diameter of 4 mm max. at 0 to 0 mm. Integrated lens 0. dia. 5 E-C4S M Spot diameter of 0. mm at 5 mm. 6 dia. 50 E-L5 M Spot diameter of 6 mm at 50 mm. 0. dia. E-C4 M + E9-FA-5 Spot diameter of 0. mm at 7 mm. 0.5 dia. 7 E-C M + E9-FA-5 E-CN M + E9-FA-5 Spot diameter of 0.5 mm at 7 mm. 0. dia. E-C4 M + E9-FB Spot diameter of 0. mm at 7 mm. Small-spot 7 E-C M + E9-FB 0.5 dia. Spot diameter of 0.5 mm at 7 mm. E-CN M + E9-FB dia. 50 E-CC00 M + E9-F8 E-CN M + E9-F8 Spot diameter of mm at 50 mm. 9
10 High-power Beam s Type ls with integrated lens ls with lenses Reflective ls with integrated lens direction *. The fiber length is 0 m on each side, so the sensing distance is given as 0,000 mm. *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. Narrow View s Aperture angle s *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. s for Detection without Background Interference Giga distance (mm) Standard Right-angle 5 E-LTN M 4,000 * 4,000 *, E-T7L 0M 0,000 * 0,000 * 0,000 * 8,000 5 E-LT M 4,000 * 4,000 * 4,000 *,080 E-LTR M 4,000 * 4,000 *, Side-view 0 E-T4 M 4,000 * 4,000 * 4,000 *,800 Right-angle E-TN M + E9-F 4,000 * 4,000 * 4,000 *,000 6 E-TN M + E9-F6 4,000 * 4,000 * 4,000 *,600 E-TR M + E9-F 4,000 * 4,000 * 4,000 *,000 6 E-TR M + E9-F6 4,000 * 4,000 * 4,000 *,600 Side-view 60 E-TR M + E9-F,70, E-T M + E9-F 4,000 * 4,000 * 4,000 *,860 6 E-T M + E9-F6 4,000 * 4,000 * 4,000 * 4,000 * Side-view 60 E-T M + E9-F,450,980,90 0 E-T5R M + E9-F 4,000 * 4,000 * 4,000 *,500 6 E-T5R M + E9-F6 4,000 * 4,000 * 4,000 * 4,000 * Side-view 60 E-T5R M + E9-F,00, E-T8R-S M + E9-F 4,000 * 4,000 * 4,000 *,000 6 E-T8R-S M + E9-F6 4,000 * 4,000 * 4,000 *,800 Side-view 60 E-T8R-S M + E9-F, E-T6-S M + E9-F 4,000 * 4,000 * 4,000 *,800 6 E-T6-S M + E9-F6 4,000 * 4,000 * 4,000 *,00 Side-view 60 E-T6-S M + E9-F,50, E-T5 M + E9-F- 4,000 * 4,000 *,450,400 6 E-T5 M + E9-F6 4,000 * 4,000 * 4,000 * 4,000 * 4 E-D6 M 40 to 4,000 * 40 to,00 40 to,50 40 to 480 direction Side-view Aperture angle.5 E-A0 M E-A0- M s Giga distance (mm) Standard 4,000 *,670, E-A04 M,90, E-T4SR M 4,000 *,00, E-T4S M 4,000 *,900, E-TS M 4,000 * 4,000 *,750,000 direction Flat-view Giga distance (mm) Standard E-L6-N M 0 to 5 0 to E-L4S M 0 to 4 Side-view E-L5L M 5.4 to 9 (center 7.) Transparent Object Detection (Retro-reflective s) Retro-reflective Feature Size s Giga distance (mm) Standard Limitedreflective E-C M + Film detection M E9-FR + E9-RP7 Square --- E-R6 5M 50 to,500 Threaded E-R M 0 to 70 0 to 50 Hex-shaped M6 E-LRNP M + E9-RP,00,800,
11 Transparent Object Detection (Limited-reflective s) Limitedreflective Feature direction Small size Flat-view distance (mm) Giga Standard Super-high-speed E-L4S M 0 to 4 Standard E-L6-N M 0 to 5 0 to Glass substrate alignment, 70 C E-A08 M 0 to Standard/long-distance E-A M to Side-view form Side-view E-L5L M 5.4 to 9 (center 7.) Glass substrate mapping, 70 C E-A09 M 5 to Chemical-resistant, Oil-resistant s Type direction distance (mm) Giga Standard Super-high-speed Oil-resistant Right-angle E-TNF M 4,000 * 4,000 * 4,000 *,00 Chemical/oil-resistant Chemical/oil-resistant at 50 C E-TF M 4,000 * 4,000 * 4,000 *,600 E-TF M 4,000 * 4,000 *,900,000 Side-view E-T4F M,00, E-T5F M 4,000 * 4,000 *, Semiconductors: Cleaning, developing, and etching; 60 C E-LFP 5M 8 to 0 mm from tip of lens (Recommended sensing distance: mm), 9 to mm from center of mounting hole A (Recommended sensing distance: mm) Reflective Semiconductors: Resist stripping; 85 C E-LFS 5M 8 to 0 mm from tip of lens (Recommended sensing distance: mm), to 44 mm from center of mounting hole A (Recommended sensing distance: 5 mm) Chemical/oil-resistant E-DF M --- * Chemical-resistant cable E-DU M, *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. *. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin. Bending-resistant s Size distance (mm) Giga Standard Super-high-speed.5 dia. E-TB M, M E-T M M4 E-T M,750,00,50 60 Square E-T5XB M Reflective.5 dia. E-DB M M E-D M dia. E-DB M M4 E-DB M M6 E-D M, Square E-D5XB M Heat-resistant s Reflective Heat-resistant temperature *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. distance (mm) Giga Standard Super-high-speed 00 C E-T5R M,400, C E-T5 M 4,000 *,50, C E-T8R-S M, C E-T6-S M,50, C E-D5R M, C E-D5 M, C E-D8R-S M C 50 C E-A08H M 0 to E-A09H M 0 to 0 (center 5) --- E-D6-S M E-D6-S M C E-D7-S M
12 Area Detection s *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. Liquid-level Detection s Vacuum-resistant s Type width Area mm *. The fiber length is m on each side, so the sensing distance is given as,000 mm. s for FPD, Semiconductors, and Solar Cells *. The fiber length is m on each side, so the sensing distance is given as 4,000 mm. distance (mm) Giga Standard Super-high-speed E-T6PR M 4,000 *,550, E-T6JR M 4,000 *,50, mm E-T6WR M 4,000 *,900, Reflective Array mm E-D6P M, Tube-mounting Liquid contact (heat-resistant up to 00 C) Limitedreflective Tube diameter Feature., 6.4, or 9.5 dia 8 to 0 dia Stable residual quantity detection Mounting at multiple levels E-A0 5M E-L5T M distance (mm) Giga Standard Super-high-speed Applicable tube: Transparent tube with a diameter of., 6.4, or 9.5 mm, Recommended wall thickness: mm Applicable tube: Transparent tube with a diameter of 8 to 0 mm, Recommended wall thickness: mm No restrictions Large tubes E-D6T 5M Applicable tube: Transparent tube (no restrictions on diameter) E-D8F 4M Liquid-contact type distance (mm) Heat-resistant temperature Giga Standard Super-high-speed E-T5V M, C E-T5V M + E9-FV,000 *,000 *,000 * C E-T84SV M,000 *, Application Operating temperature Glass presence detection 70 C Glass substrate alignment Glass substrate mapping Wet processes: Cleaning, Resist developing and etching Wet process: Resist stripping distance (mm) Giga Standard Super-high-speed E-L6-N M 0 to 5 0 to E-A08 M 0 to C E-A08H M E-A M to C E-A09 M 5 to C E-A09H M 0 to 0 (center 5) C E-LFP 5M 8 to 0 mm from tip of lens (Recommended sensing distance: mm), 9 to mm from center of mounting hole A (Recommended sensing distance: mm) 85 C E-LFS 5M 8 to 0 mm from tip of lens (Recommended sensing distance: mm), to 44 mm from center of mounting hole A (Recommended sensing distance: 5 mm) E-A0 M E-A0- M 4,000 *,670, Wafer mapping 70 C E-A04 M,90, E-T4SR M 4,000 *,00, E-T4S M 4,000 *,900,60 700
13 Infrared ls Threaded s Reflective Cylindrical s direction Size Right-angle Straight Straight Size dia. M4 E-TN M E-TR M Giga distance (mm) Standard M E-C M M6 direction E-DR M E-CC00 M Giga distance (mm) Standard E-TR M Side-view E-T4LR M Reflective dia. E-DL M Flat s Reflective direction Giga distance (mm) Standard E-T5XR M Side-view Flat-view E-T5YR M E-T5ZR M E-D5XR M Side-view Flat-view E-D5YR M E-D5ZR M Sleeve s direction High-power Beam s Giga distance (mm) Standard E-TC00BR M Reflective E-DC00BR M Type direction Aperture angle s ls with integrated lens Giga distance (mm) Standard Side-view 0 E-T4 M
14 ENX-FA I/O Circuit Diagrams NPN Operation Light- ENX-FA ENX-FA6 ENX-FA-5 ENX-FAH ENX-FAH6 Timing chart (Between brown and Dark- (Between brown and Light- ch/ ch (Between brown and black leads) ENX-FA Dark- ch/ ch (Between brown and black leads) Light- (Between brown and ENX-FA7 ENX-FA4 Dark- Light- ENX-FA7TW (Between brown and ch/ ch (Between brown and black leads) Dark- ch/ ch (Between brown and black leads) Light- (Between brown and ENX-FAAN Dark- (Between brown and L/D indicator L lit. circuit Display OUT indicator Brown Black Control output Photoelectric sensor main circuit Blue D lit. L lit. Display OUT indicator OUT indicator Brown Black Control output Orange ch Control output ch Pink Photoelectric sensor main circuit Display OUT indicator L lit. 4 Photoelectric sensor main circuit M8 Connector Pin Arrangement L lit. Display OUT indicator OUT indicator Photoelectric sensor main circuit Brown Black Control output Orange External input Blue 4 Brown Black Control output Orange ch Control output ch Display OUT indicator 0 to 0 VDC Brown Black Photoelectric sensor main circuit D lit. 0 to 0 VDC Blue D lit. L lit. 0 to 0 VDC External input Blue D lit. D lit. 0 to 0 VDC Control output Orange Analog output 0kΩ min. 0 to 0 VDC Blue 4
15 ENX-FA PNP Operation Light- ENX-FA4 ENX-FA8 ENX-FAH4 ENX-FAH8 Dark- Light- Timing chart L/D indicator L lit. Dark- Display OUT indicator (Between blue and Brown Control Black output Photoelectric sensor main circuit 0 to 0 VDC Blue D lit. (Between blue and ch/ ch L lit. ch/ ch s OUT indicator Display OUT indicator (Between blue and black leads) ENX-FA5 circuit Brown External Pink input Control output Black ch Control output Orange ch Photoelectric sensor main circuit Blue 0 to 0 VDC D lit. (Between blue and black leads) Light- ENX-FA9 ENX-FA54 Dark- Light- Display OUT indicator L lit. Photoelectric sensor main circuit (Between blue and Dark- 4 D lit. External Orange input Control Black output 0 to 0 VDC M8 Connector Pin Arrangement Blue 4 (Between blue and ch/ ch ch/ ch s OUT indicator Display L lit. (Between blue and black leads) ENX-FA9TW ENX-FA54TW Brown OUT indicator Control output Black ch Control output Orange ch Photoelectric sensor main circuit 4 D lit. Brown M8 Connector Pin Arrangement Blue 0 to 0 VDC 4 (Between blue and black leads) Light- ENX-FA4AN Dark- L lit. 表示部 OUT表示灯 橙 Brown Orange Analog output (Between blue and Photoelectric sensor main circuit Black Control output Blue 0 to 0 VDC 0kΩ min. D lit. (Between blue and 5
16 Plug (Sensor I/O Connector) 4 Terminal number 4 XSF-M4-40-A XSF-M4-405-A XSF-M4-40-A XSF-M4-405-A Wire color Brown White Blue Black Wire color Connection pin Application Brown Power supply (+V) White External input / Blue Power supply (0 V) Black 4 Nomenclature ENX-FA/FA4/FA6/FA8/FA7/FA9/FA4/FA54/ FA-5/FAH/FAH4/FAH6/FAH8/FAAN/FA4AN [L/D Indicator] Indicates the setting status: Light- (L) or Dark- (D). [OUT Indicator] Turns when the output is. [DPC Indicator] Turns when Dynamic Power Control is effective. [ST Indicator] Turns when Smart Tuning is in progress. [ L/D Button] Use to switch between Light- (L) and Dark- (D). [ Tune Button] Threshold Level Green digital display Executes Smart Tuning. Incident Level White digital display [ MODE Button] Use to switch between Detection Mode and Setting Mode. [+ UP/DOWN Button] Used to fine-tune the threshold or change set values. ENX-FA/FA5/FA7TW/FA9TW/FA54TW/FA0/FAH0 [L/D Indicator] Indicates the setting status: Light- (L) or Dark- (D). [OUT Indicator/OUT Indicator] Turns when OUT or OUT is. [DPC Indicator] Turns when Dynamic Power Control is effective. [ST Indicator] Turns when Smart Tuning is in progress. [ L/D Button] Use to switch between Light- (L) and Dark- (D). [ Tune Button] Executes Smart Tuning. Threshold Level Green digital display [OUT Selection Indicator/OUT Selection Indicator] The indicator for the selected output channel is lit. Incident Level White digital display [ MODE Button] Use to switch between Detection Mode and Setting Mode, and use to switch between OUT and OUT. [+ UP/DOWN Button] Used to fine-tune the threshold or change set values. 6
17 Safety Precautions Be sure to read the precautions for all ls in the website at: Warning Indications WARNING Precautions for Safe Use Precautions for Correct Use Warning level Indicates a potentially hazardous situation which, if not avoided, will result in minor or rate injury, or may result in serious injury or death. Additionally, there may be significant property damage. Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols General prohibition Indicates the instructions of unspecified prohibited action. Caution, explosion Indicates the possibility of explosion under specific conditions. Caution, fire Indicates the possibility of fire under specific conditions. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explosion may result. Precautions for Safe Use ENX-FA The following precautions must be observed to ensure safe operation of the Amplifier Unit. Doing so may cause damage or fire.. Do not install the product in the following locations. Locations subject to direct sunlight Locations subject to condensation due to high humidity Locations subject to corrosive gas Locations subject to vibration or mechanical shocks exceeding the rated values Locations subject to exposure to water, oil, chemicals Locations subject to stream Locations subjected to strong magnetic field or electric field. Do not use the product in environments subject to flammable or explosive gases.. Do not use the product in any atmosphere or environment that exceeds the ratings. 4. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. 5. High-voltage lines and power lines must be wired separately from the product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. 6. Do not apply any load exceeding the ratings. Otherwise, damage or fire may result. 7. Do not short the load. Otherwise, damage or fire may result. 8. Connect the load correctly. 9. Do not miswire such as the polarity of the power supply. 0.Do not use the product if the case is damaged..burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning..when setting the sensor, be sure to check safety such as by stopping the equipment..be sure to turn off the power supply before connecting or disconnecting wires. 4.Do not attempt to disassemble, repair, or modify the product in any way. 5.When disposing of the product, treat it as industrial waste. 6.Do not use the Sensor in water, rainfall, or outdoors. 7.Use the product in the IP54 enclosure. 8.UL Standard Certification (Applicable s: ENX-FA//4/5 Only) Only the sensors with Enhanced UL Certification Mark are certified by UL. They are intended to be supplied by a "Class circuit". When used in United States and Canada, Please use the same Class source for input and output.the overcurrent protection current rating is A max. They were evaluated as Open type and shall be installed within a enclosure. 7
18 Precautions for Correct Use. Be sure to mount the unit to the DIN track until it clicks.. When using the Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with EX-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using the Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with ENW-series Sensor Communications Unit). Amplifier Unit with Wiresaving Connector Amplifier Unit with Connector for Communications Unit Protective sticker Power supply connecting terminals Protective cap. The length for the cable extension must be 0 m or less (or less than 0 m for S-mark certified ls). Be sure to use a cable of at least 0. mm for extension. The power voltage must be 4 to 0 V when connecting amplifier units with extension cable and wire-saving connector. 4. Do not apply the forces on the cord exceeding the following limits: Pull: 40N; torque: 0.N m; pressure: 0N; bending: 9.4N 5. Do not apply excessive force such as tension, compression or torsion to the Amplifier Unit with the Fiber Unit fixed to the Amplifier Unit. 6. Always keep the protective cover in place when using the Amplifier Unit. Not doing so may cause malfunction. 7. It may take time until the received light intensity and measured value become stable immediately after the power is turned on depending on use environment. 8. The product is ready to operate 00 ms after the power supply is turned. 9. The Mobile Console EX-MC, EX-MC-SV and EX-MC- S cannot be connected. 0.The mutual interference prevention function does not work when in combination with EC/EC/EX..If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting in malfunction of the unit. In such case, increase the threshold..standard ls and Advanced ls The Sensor Communication Unit EX-DRT-S, EX-CRT, EX- ECT and ENW cannot be connected. for Sensor Communication Unit (ENX-FA0) The Sensor Communication Unit ENW can be connected. EX-DRT-S, EX-CRT, EX-ECT cannot be connected..if you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke immediately stop using the product, turn off the power, and consult your dealer. 4.Do not use thinner, benzene, acetone, and lamp oil for cleaning. 8
19 Dimensions Fiber Amplifier Units ENX-FA (Unit: mm) Tolerance class IT6 applies to dimensions in this data sheet unless otherwise specified. Pre-wired Amplifier Units ENX-FA(-5)/FA4/ L/D indicator DPC indicator ST indicator.7 7. OUT selection indicator OUT indicator OUT indicator ENX-FA/FA5 7.8 L/D indicator DPC indicator ST indicator *Cable Specifications ENX-FA4 ENX-FA ENX-FA5 Outer diameter No. of conductors 4.0 dia. 4.0 dia. 5 Others Conductor cross-section: 0. mm Insulator dia.: 0.9 mm Standard cable length: m Minimum bending radius: mm 0 OUT indicator 5. Threshold level (green, digital) Incident level (white, digital) Mounted to DIN Track OUT selection indicator Threshold level (green, digital) 47. (max. value with cover open) 70 (max. value with cover open) Incident level (white, digital) 5. With Mounting Bracket Attached (max. value with cover open) 4.5 Two,.4-dia..5.5 fiber unit holes (6.5) (7) (6.5) (7) * * Fiber Attachment (E9-F9) attached 0.5 (7.9) 7.8 (0.) Optical communications Two,. dia. (mounting holes) 0.5 (9.4) 6 4. Optical communications E9-L4 Mounting Bracket (sold separately, SUS04) PFP-@N DIN Track (sold separately) Mounting Holes Two, M holes 6 (9.9) 6 Amplifier Units with Wire-saving Connectors ENX-FA6 ENX-FA7(TW) ENX-FA6/FA7(TW)/FA8 ENX-FA8 /FA9(TW)/FAH6/FAH8 ENX-FA9(TW) DPC indicator ENX-FAH6 ENX-FAH8 L/D indicator.7 7. OUT indicator Threshold level (green, digital) ST indicator Incident level (white, digital) OUT selection indicator OUT indicator OUT indicator OUT selection indicator Threshold level (green, digital) ENX-FA7TW/FA9TW 7.8 L/D indicator DPC indicator ST indicator Incident level (white, digital) *Cable Specifications Outer diameter No. of conductors EX-CN.6 dia. EX-CN EX-CN 4.0 dia. EX-CN 4 0 Mounted to DIN Track With Mounting Bracket Attached (max. value with cover open) 70 (max. value with cover open) 5. (75.) 04.8 (max. value with cover open) 4.5 Two,.4-dia..5 fiber unit holes (6.5) (7).4 * ().5 (6.5) (7).4 * () 5.7 With Fiber Attachment (E9-F9) attached 0.5 (7.9) (.8) (75.) PFP-@N DIN Track (sold separately) Optical communications Wire-saving Connector (sold separately) Two,. dia. (mounting holes) 0.5 (9.4) Wire-saving Connector (sold separately) Optical communications E9-L4 Mounting Bracket (sold separately, SUS04) Mounting Holes Two, M holes (9.9) 6 6 9
20 Amplifier Units with M8 Connectors ENX-FA4 ENX-FA54 ENX-FA54TW ENX-FA4/FA54 L/D indicator DPC indicator ST indicator OUT selection indicator OUT indicator ENX-FA54TW 7.8 L/D indicator DPC indicator ST indicator Connector pin arrangement OUT indicator OUT indicator Threshold level (green, digital) 5. Incident level (white, digital) OUT selection indicator Threshold level (green, digital) Incident level (white, digital) 0 5. Mounted to DIN Track 47. (max. value with cover open) 70 (max. value with cover open) With Mounting Bracket Attached (max. value with cover open) 4.5 Two,.4-dia. fiber unit holes.5 (6.5) (5.7) PFP-@N DIN Track (sold separately) 0. Optical communications M8 Connector (9.4) Two,. dia. 7.9 (mounting holes) E9-L4 Mounting Bracket (sold separately, SUS04) Mounting Holes Two, M holes Amplifier Unit with Connector for Sensor Communications Unit ENX-FA0/FAH0 OUT selection indicator L/D indicator DPC indicator OUT indicator 7.8 ST indicator OUT indicator OUT selection indicator Threshold level (green, digital) 5. Incident level (white, digital) Mounted to DIN Track 40 (max. value with cover open) 5 (max. value with cover open) 04.8 (max. value with cover open) 4.5 Two,.4-dia. fiber unit holes.5 (6.5) (7).4 6 (9.9) 5.7 With Fiber Attachment (E9-F9) attached 0.5 (7.9) PFP-@N DIN Track (sold separately) 90.8 (9.) Optical communications 0
21 Accessories (Sold Separately) Wire-saving Connectors Master Connector EX-CN EX-CN Edge of Amplifier Unit (7), * * EX-CN: 4-dia. cable with conductors, Standard cable length: m (Conductor cross-section: 0. mm (AWG4), Insulator diameter:. mm) EX-CN: 4-dia. cable with 4 conductors, Standard cable length: m (Conductor cross-section: 0. mm (AWG4), Insulator diameter:. mm) Slave Connector EX-CN EX-CN Edge of Amplifier Unit (7), * * EX-CN:.6-dia. cable with conductor, Standard cable length: m (Conductor cross-section: 0. mm (AWG4), Insulator diameter:. mm) EX-CN: 4-dia. cable with conductors, Standard cable length: m (Conductor cross-section: 0. mm (AWG4), Insulator diameter:. mm) Sensor I/O Connectors Straight XSF-M4-40@-A L-shaped XSF-M4-40@-A
22 Mounting Bracket E9-L4 (0.) Mounting Holes Two, M holes dia. holes 7 6±0. 6 Four, Radius: max. 7.4 Material: Stainless steel (SUS04).4 DIN Track PFP-00N ±0.5 5±0. 7± (5)* 0 0,000 (500)* *Dimensions in parentheses are for the PFP-50N. Material: Aluminum PFP-00N ± ,000 Material: Aluminum End Plate PFP-M.5 50 M4 8 panhead screw 0 M4 spring washer Materials: Iron, zinc plating
23 OMR AUTOMATI AMERICAS HEADQUARTERS Chicago, IL USA OMR CANADA, INC. HEAD ICE Toronto,, Canada OMR ELECTRICS DE MEXICO HEAD ICE México DF OMR ELECTRICS DE MEXICO SALES ICE Apodaca, N.L OMR ARGENTINA SALES ICE Cono Sur OMR CHILE SALES ICE Santiago OTHER OMR LATIN AMERICA SALES OMR ELETRÔNICA DO BRASIL LTDA HEAD ICE São Paulo, SP, Brasil OMR EUROPE B.V. Wegalaan 67-69, NL- JD, Hoofddorp, The Netherlands. + (0) Authorized Distributor: Controllers & I/O Machine Automation Controllers (MAC) Motion Controllers Programmable Logic Controllers (PLC) Temperature Controllers Remote I/O Robotics Industrial Robots Mobile Robots Operator Interfaces Human Machine Interface (HMI) Motion & Drives Machine Automation Controllers (MAC) Motion Controllers Servo Systems Frequency Inverters Vision, Measurement & Identification Vision Sensors & Systems Measurement Sensors Auto Identification Systems Photoelectric Sensors Fiber-Optic Sensors Proximity Sensors Rotary Encoders Ultrasonic Sensors Safety Safety Light Curtains Safety Laser Scanners Programmable Safety Systems Safety Mats and Edges Safety Door Switches Emergency Stop Devices Safety Switches & Operator Controls Safety Monitoring/Force-guided Relays Control Components Power Supplies Timers Counters Programmable Relays Digital Panel Meters Monitoring Products Switches & Relays Limit Switches Pushbutton Switches Electromechanical Relays Solid State Relays Software Programming & Configuration Runtime E9I-E-0 Note: Specifications are subject to change. 08 Omron. All Rights Reserved. Printed in U.S.A. Printed on recycled paper.
E3NX-FA. Smart Fiber Amplifier Units. A Smart Fiber Amplifier Unit with Ultra-stable Detection and Ultra-easy Setup. Ordering Information
Smart Fiber Amplifier Units ENX-FA CSM_ENX-FA_DS_E_5_ A Smart Fiber Amplifier Unit with Ultra-stable Detection and Ultra-easy Setup Improved basic performance with.5 times the sensing distance and approx.
More informationPre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8
Smart Fiber Amplifier Units ENX-FA CSM_ENX-FA_DS_E_4_ A Smart Fiber Amplifier Unit with Ultra-stable Detection and Ultra-easy Setup Improved basic performance with.5 times the sensing distance and approx.
More informationPre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8
Smart Fiber Amplifier Units ENX-FA CSM_ENX-FA_DS_E_7_ The Advanced Fiber Amplifier Units That Handles On-site Needs Improved basic performance with.5 times the sensing distance and approx. /0th the minimum
More informationE3X-DA0-S. Digital Fiber Amplifier Unit. Stable Detection with Advanced Fiber Amplifier Units. Ordering Information. Fiber Amplifier Units
Digital Fiber Amplifier Unit E3X-DA-S Stable Detection with Advanced Fiber Amplifier Units A wide range of added value with standard ls with one input and two outputs, and ultra-long-term APC ls with an
More informationHigh Performance Fiber Amplifiers with Unmatched Stability and Resolution
NEW Presence Measurement Smart Fiber Amplifier Units E3NX-FA High Performance Fiber Amplifiers with Unmatched Stability and Resolution A New Level of Performance Presence Measurement Simple and Dependable
More informationIndustry-leading Levels * of Performance Highly Stable Detection
NEW Presence Detection Measurement Smart Fiber Amplifier Units E3NX-FA Industry-leading Levels of Performance Highly Stable Detection Easy Setup for Any Workpiece by Any Operator For performance (sensing
More informationSmart Fiber Amplifier Units E3NX-FA
NEW Presence Detection Measurement Smart Fiber Amplifier Units E3NX-FA Industry-leading Levels of Performance Highly Stable Detection Easy Setup for Any Workpiece by Any Operator For performance (sensing
More informationIndustry-leading Levels * of Performance Highly Stable Detection
NEW Presence Detection Measurement Smart Fiber Amplifier Units E3NX-FA Industry-leading Levels of Performance Highly Stable Detection Easy Setup for Any Workpiece by Any Operator For performance (sensing
More informationE3X-DA0-S. Digital Fiber Amplifier Unit. Stable Detection with Advanced Fiber Amplifier Units. Ordering Information. Fiber Amplifier Units
Digital Fiber Amplifier Unit E3X-DA-S Stable Detection with Advanced Fiber Amplifier Units A wide range of added value with standard ls with one input and two outputs, and ultra-long-term APC ls with an
More informationE3NC. Smart Laser Sensors. Ideal for Applications That Cannot Be Handled with Fiber Sensors or Photoelectric Sensors. Features
Smart Laser Sensors ENC CSM_ENC_DS_E 1 Ideal for Applications That Cannot Be Handled with Fiber Sensors or Photoelectric Sensors A wide variety of easy-to-use Laser Photoelectric Sensor Heads. Coaxial
More informationE3NC-L/E3NC-S. Smart Laser Sensors. Best fit for challenging sensing applications. Laser Sensors for highest precision detection
E3NC-L/E3NC-S Smart Laser Sensors Best fit for challenging sensing applications Laser Sensors for highest precision detection Presence Detection Measurement Simpler and More Dependable The N-Smart Lineup
More informationGreater Flexibility in Equipment Design
NEW Presence Detection Measurement Smart Fiber Amplifier Units (2-channel models) Greater Flexibility in Equipment Design Same size as the 1-ch model: 10 mm Actual size 2-channel Amplifier reduces installation
More informationPhotoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.
More informationOMRON APPLICATION NOTE
OMRON APPLICATION NOTE Automatic PID Selection for E5_N-H and E5_N-HT Temperature Controllers This document explains: Parameters used for automatic PID selection Provides application examples using Analog
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationE3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)
Distance-settable Photoelectric Sensor Switching between background and foreground suppression (BGS/FGS) enables detecting a variety of objects under various background/foreground conditions. Influence
More informationE2C-EDA. Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings. Ordering Information
Authorised Distributors:Intech Systems Chennai Pvt. Ltd, Chennai-00 032 Ph: +91 44 4353 Fax: 044 4353 7 E-mail: info@intechchennai.com Website: www.intechchennai.com High Precision Positioning Inductive
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationE3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features
bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that
More informationOperating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)
Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting
More informationZ4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.
/ Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance
More informationSensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m
Photoelectric Sensor with Built-in Amplifier CSM DS_E 1 General-purpose Photoelectric Sensor for High Quality and Reliable Detection Be sure to read Safety Precautions on page 8. Ordering Information General-purpose
More informationTechnical Explanation for Fiber Sensors
CSM_FiberSensor_TG_E_1_2 Introduction What Is a Fiber Sensor? A Fiber Sensor is a type of Photoelectric Sensor that enables detection of objects in narrow locations by transmitting light from a Fiber Amplifier
More informationSensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view
R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained
More informationLabel Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor
Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN
More informationConnections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON
Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures
More informationBuilt-in Amplifier Photoelectric Sensor
Built-in Amplifier Photoelectric Sensor Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance Conforms to EN and IEC standards Incorporating polarizing function,
More informationClass II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.
Distance-settable Photoelectric Sensor FC-AL Distance-settable Photoelectric Sensor with Background Suppression and Visible Laser Beam Reliable background suppression detection, even of shiny objects Detection
More informationAccurax G5 Servo System
Servo System Extreme mechatronics meets -Stream Automation»» Sub micron precision and ms settling time»» Motion network and safety built-in»» Double registration and full closed loop G5 Series Servo System
More informationBuilt-in Amplifier Photoelectric Sensor
Built-in Amplifier Photoelectric Sensor Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance Conforms to EN and IEC standards Incorporating polarizing function,
More informationNon-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)
Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type) ECY-SD Proximity Sensor with Separate Amplifier Unit for Detection of Non-ferrous Metals with Simple Adjustment Detects aluminum,
More informationSurprisingly Stable Detection with Your Finger tip
NEW Fiber Sensor S mart Fiber Measurement Discrimination Presence Surprisingly Stable Detection with Your Finger tip Exceptionally easy operation and stabilizing technology reduce maintenance cost. Communications
More informationE3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor
Authorised Distributors:- AS & AAIN INDIA PVT TD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) Tel : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Fiber Glossy Object
More informationTL-W5MD1 2M *1 *3 TL-W5MD2 2M
Flat Inductive CSM DS_E_9_ Standard Flat s in Many Different Variations Only mm thick yet provides a sensing distance of mm (MC). Aluminum die-cast models also available. Be sure to read Safety Precautions
More informationSensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view
R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained
More informationGet the Ability to Handle Applications
NEW Presence Detection Measurement Smart Laser Sensors E3NC-L/E3NC-S Get the Ability to Handle Applications Beyond the Realm of Fiber Sensors Compact Laser Sensors E3NC-L Ultra-compact CMOS Laser Sensors
More informationSurprisingly Stable Detection with Your Finger tip
NEW Fiber Sensor S mart Fiber Measurement Discrimination Presence Surprisingly Stable Detection with Your Finger tip Exceptionally easy operation and stabilizing technology reduce maintenance cost. Communications
More information10 to 30 VDC (10% max. permissable ripple peak-to-peak)
R Background Suppression Sensor Photoelectric Sensor With Adjustable Setting Distance in Rugged Metal Housing H Stable detection regardless of material color or size of sensing object: 2% or less black/white
More informationCapacitive Proximity Sensor
Capacitive Proximity Sensor Compact and Ideal for Robot Hands and Various Built-in Applications for LCD, Wafer, and PDP (Plasma Display Panel) Detection Flat head is only 5.5-mm thick. Robot Cable ensures
More informationSensor Communications Unit Distributed Sensor Unit E3NW Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units
NEW E3NW Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units Introduction Commissioning Operation Lower Costs Less Time Higher Productivity E3NW-DS E3NW-ECT BEST PRICE
More informationE3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance
Built-in Amplifier Photoelectric Sensor Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance Satisfies the requirements of IP67, NEMA 6P, and IP67G (oil-tight).
More informationE3S-A/B. Built-in Amplifier Photoelectric Sensor. Ordering Information. Revolutionary High-performance High-quality Sensor with Built-in Amp
Built-in Amplifier Photoelectric Sensor Revolutionary High-performance High-quality Sensor with Built-in Amp can be adjusted in seconds because the optical axis coincides with the mounting axis. Highly
More informationLaser Displacement Sensor Z4M. Ordering Information
Laser Displacement Sensor Compact Displacement Sensor with 1.5-micron Resolution Offers Long-distance Measurement for In-line Production Inspection High resolution with 3 user-selectable response speed
More informationFEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.
273 Cylindrical Photoelectric Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO PHOTO MEASURE -LS200
More informationFluoro plastic housing for highest chemical and detergent resistance
Chemical Resistant Inductive Proximity Sensor E2FQ Fluoro plastic housing for highest chemical and detergent resistance Ordering Information Shape Shielded Sensing distance PNP (NO) DC 3-wire models NPN
More informationLine Stoppages a thing of the past with GIGA RAY
High Functionality Digital Fiber Sensor DA-S Series Line Stoppages a thing of the past with GIGA RAY GIGA APower r Lighting g in ge Element ent Tough Fiber Sensor Standard models DA21-S New lineup released
More informationLong Range Metal Body Sensor
R Long Range Metal Body Sensor 30 m Range With Advanced Fuzzy Logic H Mutual interference protection H NPN/PNP switch selectable output H M12 plug-in connector H Meets IP67 and NEMA 4X, 6P H Vibration
More informationSensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)
Photoelectric Sensor with Built-in Amplifier CSM DS_E_11_1 General-purpose Photoelectric Sensor for High Quality and Reliable Detection Be sure to read Safety Precautions on page 8. Note: -2/-/-DS10/-DS30/-R2
More informationHigh Reliability Of Fiber Optic Amplifier For Convenient Mounting
Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse
More informationPhotoelectric Sensor
Photoelectric Sensor Revolutionary High-performance High-quality Sensor with Built-in Amp can be adjusted in seconds because the optical axis coincides with the mounting axis. Highly visible spot on white
More informationProduct Discontinuation Notices
PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Ultrasonic Sensors No. 2011264E Discontinuation Notice of Ultrasonic Sensor E4A special specification model, E4B special specification model,
More informationParallel Beam Linear Sensor
Parallel Beam Linear Sensor Visible Red Class II Laser Width/Profile Measurement Sensor Providing High-Speed Precision Measurement with Flexible Operation H FDA Class II IEC Class 2 visible red laser ensures
More informationIndustry's standard of transparent object detection sensor
412 Stainless protector/small type series SR-Q series Industry's standard of transparent object detection sensor Stable detection even at close distances Visible red spot light KR-Q series Narrow view
More informationRevolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units
NEW E3NW Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units Introduction Commissioning Operation Lower Costs Less Time Higher Productivity E3NW-DS BEST PRICE E3NW-ECT
More informationRevolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units
NEW E3NW Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units Introduction Commissioning Operation Lower Costs Less Time Higher Productivity E3NW-DS BEST PRICE E3NW-ECT
More informationApplication Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.
Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Long-distance detection of up to 6,000 mm supports a wide variety of applications. The Sensor is not
More informationApplication Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.
Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting
More informationDigital Fiber-Optic Switches
CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the
More informationLong Range Metal Body Sensor
R Long Range Metal Body Sensor 30 m Range With Advanced Fuzzy Logic H Mutual interference protection H NPN/PNP switch selectable output H M12 plug-in connector H Meets IP67 and NEMA 4X, 6P H Vibration
More informationZ500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System
Profile Measuring System High-Precision Sensor that Measures and Displays an Object's Profile. Features OMRON's original line beam method provides a complete solution to profile measurement problems. Conventional
More informationTL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models
Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1
More informationMost Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.
/ Length (2D CMOS Laser Type) Advanced Functions Integrated into a Compact Sensor for Easy Handling of High-grade Applications A Controller the size of a business card combined with the smallest Sensor
More informationDigital Amplifier Ultrasonic Sensor E4C-UDA Series
Digital Amplifier Ultrasonic Sensor E4C-UDA Series A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Sensor Heads Head Variations 300-mm Model E4C-DS30 Sensing Distance:
More informationLX-100 SERIES. Digital Mark Sensor Amplifier Built-in. Introduction of the 3 LED mark sensor 4:1. Can detect any mark!
899 PHOTO PHOTO Digital Mark Sensor Amplifier Built-in SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.149~ guide...p.86~ General precautions... P.12~ Recognition
More informationEE-SX770/771/772/870/871/872(A/P/R)
EE-SX770/771/772/870/871/872(A/P/R) Thin, Compact Photomicrosensor with Attached Cable H Next generation design available with NPN or output H Allows standard M3-screw mounting H Twenty-four models available
More informationE2B PROXIMITY SENSORS
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-00 0 Ph: +9 8888 Fax: 0 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com EB PROIMITY SENSORS A ne w g ener ation in
More informationGeneral-Purpose Photoelectric Sensors with Self-Contained Amplifier
General-Purpose Photoelectric Sensors with Self-Contained Amplifier HP Series The convenience of industry standards, plus reliability. Effective light axis alignment 50% power savings Prevention of accidental
More informationLX-100 SERIES Conforming to EMC Directive
PHOTOELECTRIC SENSOR DIGITAL MARK SENSOR LX-100 SERIES Conforming to EMC Directive Introducing the ultimate mark sensor High resolution A/D converter Automatic optimal LED selection function Lead-free
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
44 PHOTO PHOTO Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F- Glossary of terms... P.549~ guide... P.49~ General precautions...p.55~ Recognition Make sure to use
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up
More informationE3S-CL. Distance setting photoelectric sensor in metal housing. Features
Distance setting photoelectric sensor in metal housing High water, oil and detergent resistance Minimal black/white error for highest reliability detecting different colored objects () Features Eliminates
More informationCylindrical Photoelectric Sensor
SERIES Cylindrical Photoelectric Amplifier Built-in Cylindrical type easily mountable with M Conforming to EMC Directive AC supply type conforms to Low Voltage Directive, too. ( ) UL Recognition M This
More informationPre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.
Pre-wired Photomicrosensor with Amplifier and Cable CSM_EE-SPW1_41_DS_E_5_ Compact, Thin-profile Photomicrosensor with special amplifier. Slim amplifier ( 7.5 1 mm) can be handled like a cable. Provided
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationRemote Sensor Amplifier Terminal
9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points
More informationEE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com An Ideal Photomicrosensor for Detecting
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects
929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~
More informationUltraminiature Photoelectric Switches with Self-contained Amplifier
Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x
More informationHG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications
215 PHOTO PHOTO LIGHT CURTAINS / USE Micro Laser Distance Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms / General precautions.. P.1455~ / P.1458~ Sensor selection
More informationSilicon Wafer Mapping Sensor F3M-S. Ordering Information. Application Examples. Allows Simultaneous Mapping of up to 25 Silicon Wafers
R Silicon Wafer Mapping Sensor Allows Simultaneous Mapping of up to 25 Silicon Wafers H Economical, one sensor detects most wafer types, including dummy wafers H Models match wafer sizes of 300 mm, 200
More informationEmitting and receiving element pitch: 10 mm in
Small / Slim Object Detection Area Sensor Cross-beam scanning system to detect slim objects Letter or visiting card detectable! Slim objects can be detected by using the cross-beam scanning system. Emitting
More informationEE-SPY311/411/312/412
Accurately Detects Objects Placed in Front of Mirror-like Background H A mirror-like background can be used when the distance between the sensor and the background is 20 mm or more H Detects an object
More informationSelf-contained Photoelectric Sensors PZ2 Series
Self-contained PZ Series Features World s smallest photoelectric sensors Excellent mirror surface detection IP-7 rated waterproof can operate side by side Detecting Distance Thrubeam 7, Retro-reflective
More information40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES
9 0 mm Beam Pitch General Purpose Area Sensor SERIES Related Information General terms and conditions... F- Glossary of terms / General precautions...p.59~ / P.55~ guide... P.9~ Korea s S-mark... P.60
More informationUSER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor
Amplifier Built-in Ultra-compact Type Photoelectric Sensor EX-20 Series USER S MANUAL WUME-EX20-3 Contens 1. Cautions 3 2. Part Description 4 3. Mounting 6 3-1 Mounting the sensor 6 3-2 Mounting to sensor
More informationRemote Sensor Amplifier Terminal
9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points
More informationNA DigiParts GmbH. Small / Slim Object Detection Area Sensor
953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business
More informationEasy to replace. A pigtailed type sensor with connector (CY- -J), which is easy to replace, is also available. Environment resistant
EQ- VF NX PM PM MS-AJ RT-6 PX- PHOTOELECTRIC SENSORS Mounting Stand SERIES Cylindrical Photoelectric Test input PNP output Light intensity type available monitor M This sensor has an M size for convenient
More informationEE-SPY311/411/312/412
Accurately Detects Objects Placed in Front of Mirror-like Background A mirror-like background can be used when the distance between the sensor and the background is 20 mm or more Detects an object as small
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
497 Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.59~ Sensor selection guide... P.475~ General precautions...p.5 PHOTO PHOTO Conforming
More informationE3Z. 30 m. 20 cm. 4 m. 1 m. Compact Photoelectric Sensor with Built-in Amplifier
Compact Photoelectric Sensor with Built-in Amplifier EZ CSM_EZ_DS_E The Standard for Photoelectric Sensors with a Secure Track Record of One Million Sold early. Long sensing distance of m for Through-beam
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationStable, Easy & Affordable
SMART Sensor Series Laser Displacement Sensor CMOS Type Model ZX2 Series Stable, Easy & Affordable New Regular-reflective Sensor Head Designed for Optimal Wafer Measurement Black coating White coating
More informationE2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)
Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle
More informationLED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
More informationLaser Photoelectric Sensor
Laser Photoelectric Sensor Prewired DC Sensor Provides Long- Distance Sensing of Objects as Small as 0.1 mm Detect small objects over longer sensing distances with highly accurate positioning Attachable
More informationLaser Photoelectric Sensor
Sensing Supply voltage Output Laser beam Laser beam 12-24 VDC ±10% 2 m, 10 m 20 to 50 m 80 ma Laser Photoelectric Sensor Prewired DC Sensor Provides Long-Distance Sensing of Objects as Small as 0.1 mm
More informationUltra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor
43 PHOTO PHOTO Ultra-slim Sensor NA-PK5 SERIES SERIES General terms and conditions... F-3 guide... P.49~ Related Information Glossary of terms... P.549~ General precautions... P.55~ Recognition Make sure
More informationColor Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up
909 PHOTO PHOTO Color Sensor FZ SERIES Related Information General terms and conditions... F3 Glossary of terms... P.1549~ guide...p.65~ General precautions... P.155~ Recognition MEASURE panasonic.net/id/pidsx/global
More informationLED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
More information