1 61909 pren :2017 IEC :201X (62D/1475/) (EQV) EN :2009/prA2:2017 IEC :2009/A2:201X (62B/1047/) (EQV) EN :2013/prA1:2017 IEC :2013/A1:201X (14/903/) (EQV) pren 60376:2017 IEC 60376:201X (10/1017/) (EQV) FprEN :2017 IEC :2015 (EQV) FprEN :2017 IEC/IEEE :2016 (EQV) pren :2017 IEC :201X (57/1860/) (EQV) pren TC8X_63319_enq1lt.pdf pren TC8X_63321_enq1lt.pdf pren 55015:2017 CISPR 15:201X (CIS/F/701/) (EQV) Medical electrical equipment - Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air Specification of technical grade sulphur hexafluoride (SF6) and complementary gases to be used in its mixtures for use in electrical equipment Nuclear powers plants - Instrumentation and control important to safety - Management of ageing of sensors and transmitters - Part 1: Pressure transmitters Nuclear facilities - Electrical equipment important to safety - Qualification Power systems management and associated information exchange - Data and communications security - Part 4: Profiles including MMS Zdravotnícke elektrické prístroje. Časť 2-60: Osobitné požiadavky na základnú bezpečnosť a nevyhnutné prevádzkové vlastnosti stomatologických prístrojov Zdravotnícke elektrické prístroje. Časť 2-54: Osobitné požiadavky na základnú bezpečnosť a nevyhnutné prevádzkové vlastnosti röntgenových prístrojov na skiagrafiu a skiaskopiu Výkonové transformátory. Časť 3: Izolačné hladiny, skúšky elektrickej pevnosti a vonkajšie vzdušné vzdialenosti Špecifikácia hexafluoridu síry (SF6) technického stupňa čistoty a plynov používaných v zmesiach s SF6 na používanie v elektrických zariadeniach Jadrové elektrárne. Prístrojové vybavenie a riadenie dôležité pre bezpečnosť. Manažérstvo starnutia snímačov a prevodníkov. Časť 1: Prevodníky tlaku Jadrové zariadenia. Elektrické zariadenie dôležité pre bezpečnosť. Kvalifikácia Riadenie elektrických výkonových sústav a pridružená výmena informácií. Bezpečnosť údajov a komunikácie. Časť 4: Profily s MMS Requirements for generating plants to be Požiadavky na generátory určené na pripojenie connected in parallel with distribution networks - paralelne s distribučnou sieťou. Časť 1: Part 1-1: Connection to a LV distribution Pripojenie na distribučnú sieť nízkeho napätia network - Generating plants up to and including (LV). Generátory do typu A vrátane Type A Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Požiadavky na generátory určené na pripojenie paralelne s distribučnou sieťou. Časť 2: Pripojenie na distribučnú sieť vysokého napätia (MV) Medze a metódy merania charakteristík rádiového rušenia zariadení elektrického osvetlenia a podobných zariadení MDD_93 (93/42/EEC) M/295 MDD_93 (93/42/EEC) M/295 RfG (2016/631) M/490 RfG (2016/631) M/490 EMC_2014 (2014/30/EU) M/ CLC/TC 62 IEC/SC 62D CLC/TC 62 IEC/SC 62B CLC/TC 14 IEC/TC CLC/SR 10 IEC/TC CLC/TC 45AX IEC/SC 45A CLC/TC 45AX IEC/SC 45A CLC/TC 57 IEC/TC CLC/TC 8X CLC/TC 8X CLC/TC 210 IEC/SC CISPR/F 1 z 6
2 63392 pren 62731:2017 IEC 62731:201X (100/2897/) (EQV) CLC/FprTR SC205A_62146_vot1lt.pdf Text to speech for television - General requirements Prevod textu na reč pre televíziu. Všeobecné požiadavky Investigation Results on Electromagnetic Výsledky výskumu elektromagnetického Interference in the Frequency Range below 150 rušenia vo frekvenčnom pásme pod 150 khz khz EMC_2014 (2014/30/EU), MID_2004 (2004/22/EC) M/441, M/ CLC/TC 100X IEC/TC CLC/SC 205A Vote for TS/TR FprEN 50665:2017 TC106X_62148_vot2lt.pdf Generic standard for assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz GHz) Všeobecné normy na posudzovanie elektronických a elektrických zariadení z hľadiska obmedzení expozície osôb elektromagnetickým poliam (0 Hz GHz),, EMF_2013 (2013/35/EU) M/351,, M/ CLC/TC 106X FprEN 50664:2017 TC106X_62175_vot2lt.pdf Generic standard to demonstrate the compliance of equipment used by workers with limits on exposure to electromagnetic fields (0 Hz GHz), when put into service or in situ Všeobecné normy na preukázanie zhody zariadení používaných pracovníkmi z hľadiska obmedzení expozície elektromagnetickým poliam (0 Hz GHz) po uvedení týchto zariadení do prevádzky alebo pri ich používaní na pracovisku EMF_2013 (2013/35/EU),, M/351,, M/ CLC/TC 106X pren :2017 IEC :201X (68/572/) (EQV) pren :2017 IEC :201X (68/571/) (EQV) pren :2017 IEC :201X (68/570/) (EQV) pren :2017 IEC :201X (47/2386/) (EQV) Magnetic materials - Part 6: Methods of Magnetické materiály. Časť 6: Metódy merania measurement of the magnetic properties of magnetických vlastností magneticky mäkkých magnetically soft metallic and powder materials kovových a práškových materiálov pri at frequencies in the range 20 Hz to 200 khz by frekvenciách v rozsahu od 20 Hz do 200 khz the use of ring specimens použitím vzoriek kruhového tvaru Magnetic materials - Part 8-11: Specifications for individual materials - Fe-based amorphous strip delivered in the semi-processed state Magnetic materials - Part 16: Methods of measurement of the magnetic properties of Febased amorphous strip by means of a single sheet tester Semiconductor devices - Mechanical and climatic test methods - Part 12: Vibration, variable frequency Magnetické materiály. Časť 8-11: Špecifikácia jednotlivých materiálov. Amorfné pásy na báze železa dodávané v čiastočne spracovanom stave Magnetické materiály. Časť 16: Metódy merania magnetických vlastností amorfných pásov na báze železa pomocou jednoduchej skúšky plechu Polovodičové súčiastky. Mechanické a klimatické skúšobné metódy. Časť 12: Vibrácie, premenlivá frekvencia CLC/SR CLC/SR CLC/SR CLC/SR 47 IEC/TC 47 2 z 6
3 64797 EN :2015/prA1:2017 IEC :2015/A1:201X (66/632/) (EQV) Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement Bezpečnostné požiadavky na elektrické zariadenia na meranie, riadenie a laboratórne použitie. Časť 031: Bezpečnostné požiadavky na ručné zostavy sond na meranie a skúšanie CLC/SR 66 IEC/TC FprEN TC111X_59265_vot1lt.pdf Collection, logistics & treatment requirements for WEEE - Part 2-4: Treatment requirements for photovoltaic panels Požiadavky na zber, logistiku a spracovanie OEEZ. Časť 2-4: Požiadavky na spracovanie fotovoltických panelov WEEE_2012 (2012/19/EU) M/ CLC/TC 111X CLC/FprTS TC111X_63021_vot1lt.pdf Collection, logistics & Treatment requirements for WEEE - Part 3-5: Technical specification for de-pollution - Photovoltaic panels Požiadavky na zber, logistiku a spracovanie OEEZ. Časť 3-5: Technická špecifikácia na dekontamináciu. Fotovoltické panely. WEEE_2012 (2012/19/EU) M/ CLC/TC 111X Vote for TS/TR pren :2017 IEC :201X (100/2913/) (EQV) Cable networks for television signals, sound signals and interactive services - Part 113: Optical systems for broadcast signal transmissions loaded with digital channels only Káblové siete pre televízne signály, rozhlasové signály a interaktívne služby. Časť 113: Optické systémy na prenos vysielaného signálu pri zaťažení digitálnych kanálov CLC/SR 100 IEC/TC pren {fragment 1}:2017 IEC :201X {fragment 1} (61H/346/) (EQV) pren {fragment 2}:2017 IEC :201X {fragment 2} (61H/347/) (EQV) pren :2017 IEC :201X (65/663/) (EQV) Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers Industrial communication networks - Security for industrial automation and control systems - Part 4-2: Technical security requirements for IACS components Elektrické spotrebiče pre domácnosť a na podobné účely. Bezpečnosť. Časť 2-76: Osobitné požiadavky na napájacie zariadenia elektrických ohrád Elektrické spotrebiče pre domácnosť a na podobné účely. Bezpečnosť. Časť 2-76: Osobitné požiadavky na napájacie zariadenia elektrických ohrád Priemyselné komunikačné siete. Informačná bezpečnosť priemyselných automatizačných a riadiacich systémov. Časť 4-2: Bezpečnostné technické požiadavky na komponenty IACS CLC/TC 61 IEC/SC 61H CLC/TC 61 IEC/SC 61H CLC/TC 65X IEC/TC pren :2017 IEC :201X (68/574/) (EQV) pren :2017 IEC :201X (86A/1792/) (EQV) Magnetic materials - Part 13: Methods of measurement of resistivity, density and stacking factor of electrical steel strip and sheet Optical fibres - Part 1-54: Measurement methods and test procedures - Gamma irradiation Magnetické materiály. Časť 13: Metódy merania rezistivity, hustoty a faktora plnenia oceľových pásov a plechov pre elektrotechniku Optické vlákna. Časť 1-54: Metódy merania a skúšobné postupy. Ožarovanie gama CLC/SR CLC/TC 86A IEC/SC 86A 3 z 6
4 62704 pren :2017 IEC :201X (112/388/) (EQV) EN :2009/prA2:2017 IEC :2000/A2:201X (20/1721/) (EQV) pren :2017 IEC :201X (90/384/) (EQV) pren 62853:2017 IEC 62853:201X (56/1734/) (EQV) EN :2016/prA1:2017 IEC :2015/A1:201X (46/645/) (EQV) Electrical insulation systems - Procedures for thermal evaluation - Part 33: Multifactor evaluation with increased factors at elevated temperature Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus Superconductivity - Part 24: Critical current measurement - Retained critical current after double bending at room temperature of Agsheathed Bi-2223 superconducting wires Elektroizolačné systémy. Postupy na tepelné hodnotenie. Časť 33: Multifaktorové hodnotenie so zvýšenými faktormi pri zvýšenej teplote Skúšky elektrických a optovláknových káblov v podmienkach horenia. Časť 3-10: Skúška vertikálne šíreným plameňom na vertikálne uložených vodičoch alebo kábloch vo zväzkoch. Zariadenia Supravodivosť. Časť 24: Meranie kritického prúdu. Zachovaný kritický prúd supravodivých drôtov Bi-2223 so strieborným plášťom po dvojitom ohybe pri izbovej tepote CLC/SR 112 IEC/TC CLC/TC 20 IEC/TC CLC/SR 90 IEC/TC 90 Open systems dependability Spoľahlivosť otvorených systémov CLC/SR 56 IEC/TC 56 Test method for measuring the transfer impedance ZT and the screening attenuation as or coupling attenuation ac of RF-connectors and assemblies up to and above 3 GHz, triaxial tube in tube method Skúšobné metódy kovových komunikačných káblov. Časť 4-7: Elektromagnetická kompatibilita (EMC). Skúšobná metóda na meranie prenosovej impedancie ZT a tlmenia tienenia as alebo tlmenia spojenia ac VF konektorov a súborov do 3 GHz a nad 3 GHz, triaxiálna metóda rúrka v rúrke EMC_2014 (2014/30/EU) CLC/TC 46X IEC/TC pren :2017 SC46XA_59945_enq2lt.pdf Coaxial cables - Part 9-1: Sectional and digital signal transmission - Indoor drop cables for systems operating at Koaxiálne káble. Časť 9-1: Rámcová digitálny prenos signálu. Káble na vnútorné do pren :2017 SC46XA_59946_enq2lt.pdf Coaxial cables - Part 9-2: Sectional and digital signal transmission - Indoor drop cables for systems operating at Koaxiálne káble. Časť 9-2: Rámcová digitálny prenos signálu. Káble na vnútorné do z 6
5 59947 pren :2017 SC46XA_59947_enq2lt.pdf Coaxial cables - Part 9-3: Sectional and digital signal transmission - Indoor drop cables for systems operating at Koaxiálne káble. Časť 9-3: Rámcová digitálny prenos signálu. Káble na vnútorné do pren :2017 SC46XA_59948_enq2lt.pdf Coaxial cables - Part 10-1: Sectional and digital signal transmission - Outdoor drop cables for systems operating at Koaxiálne káble. Časť 10-1: Rámcová digitálny prenos signálu. Káble na vonkajšie do pren :2017 SC46XA_59949_enq2lt.pdf Coaxial cables - Part 10-2: Sectional and digital signal transmission - Outdoor drop cables for systems operating at Koaxiálne káble. Časť 10-2: Rámcová digitálny prenos signálu. Káble na vonkajšie do pren :2017 SC46XA_59950_enq2lt.pdf pren :2017 SC46XA_59951_enq2lt.pdf pren :2017 SC46XA_63168_enq1lt.pdf Coaxial cables - Part 11-1: Sectional and digital signal transmission - Distribution and trunk cables for systems operating at Coaxial cables - Part 11-2: Sectional and digital signal transmission - Distribution and trunk cables for systems operating at Koaxiálne káble. Časť 11-1: Rámcová digitálny prenos signálu. Rozvodné a diaľkové káble pre systémy pracujúce v rozsahu od 5 do Koaxiálne káble. Časť 11-2: Rámcová digitálny prenos signálu. Rozvodné a diaľkové káble pre systémy pracujúce v rozsahu od 5 do Coaxial cables - Part 1: Generic specification Koaxiálne káble. Časť 1: Kmeňová špecifikácia, M/212,, M/ pren :2017 IEC :201X (55/1612/) (EQV) pren :2017 IEC :201X (55/1613/) (EQV) Specifications for particular types of winding wires - Part 73: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular aluminium wire, class 200 Specifications for particular types of winding wires - Part 74: Polyesterimide enamelled rectangular aluminium wire, class 180 Špecifikácie jednotlivých typov vodičov na vinutia. Časť 73: Hliníkový vodič pravouhlého prierezu lakovaný polyesterom alebo polyesterimidom, s vonkajšou vrstvou z polyamid-imidu, trieda 200 Špecifikácie jednotlivých typov vodičov na vinutia. Časť 74: Hliníkový vodič pravouhlého prierezu lakovaný polyesterimidom, trieda CLC/TC 55 IEC/TC CLC/TC 55 IEC/TC 55 5 z 6
6 64117 pren :2017 IEC :201X (90/387/) (EQV) pren :2017 IEC :201X (23J/432/) (EQV) pren :2017 IEC :201X (23J/433/) (EQV) pren :2017 IEC :201X (23J/434/) (EQV) pren :2017 IEC :201X (23J/435/) (EQV) pren :2017 IEC :201X (51/1181/) (EQV) pren IEC :2015 (MOD) pren ECSS-E-ST-31-04C (EQV) FprEN ECSS-Q-ST-40C (EQV) FprEN ECSS-Q-ST-30C (EQV) Superconductivity - Part 23: Residual resistance ratio measurement - Residual resistance ratio of Nb superconductors Switches for appliances - Part 2-1: Particular requirements for cord switches Switches for appliances - Part 2-4: Particular requirements for independently mounted switches Switches for appliances - Part 2-5: Particular requirements for change-over selectors Supravodivosť. Časť 23: Meranie pomeru zvyškového odporu. Pomer zvyškového odporu Nb supravodičov Spínače na spotrebiče. Časť 2-1: Osobitné požiadavky na šnúrové spínače Spínače na spotrebiče. Časť 2-4: Osobitné požiadavky na samostatne pripevnené spínače Spínače na spotrebiče. Časť 2-5: Osobitné požiadavky na voliče Switches for appliances - Part 2-6: Particular Spínače na spotrebiče. Časť 2-6: Osobitné requirements for switches used in electric motor-požiadavkoperated hand-held tools, transportable tools elektrickom ručnom náradí, prenosnom náradí na spínače používané v and lawn and garden machinery a strojových zariadeniach pre trávnik a záhradu Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 7: EERcores Feritové jadrá. Návody na rozmery a medze povrchových nerovnomerností. Časť 7: Jadrá EER Electrical accessories - Circuit-breakers for Elektrické príslušenstvo. Ističe na nadprúdové overcurrent protection for household and similar istenie domových a podobných inštalácií. Časť installations - Part 1: Circuit-breakers for a.c. 1: Ističe určené na prevádzku pri striedavom operation prúde Exchange of Thermal Model Data for Space Výmena údajov tepelných modelov pre Applications vesmírne aplikácie Space product assurance - Safety Zabezpečovanie výrobkov kozmického programu. Bezpečnosť Space product assurance - Dependability Zabezpečovanie výrobkov kozmického programu. Spoľahlivosť,,, CLC/SR 90 IEC/TC CLC/SR 51 IEC/TC CLC/TC 23E IEC/SC 23E M/ CEN/CLC/TC 5 M/ CEN/CLC/TC 5 M/ CEN/CLC/TC 5 6 z 6
Powered Traction Unit OPERATION MANUAL
Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED
More informationTechnical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure
Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure International Electrotechnical Commission Michel Bourdages Secretary International
More informationBIODEX MULTI- JOINT SYSTEM
BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head Office Vijzelmolenlaan 5 & 7 3447 GX oerden The Netherlands Location Abbreviation/ location code Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationEnglish
English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm
More informationThis annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation
Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationConducted emission pre compliance measurements
V1.1 Conducted emission pre compliance measurements All electronic products need to be tested for electromagnetic emissions that may negatively effect the correct operation of other equipment nearby. Electromagnetic
More informationLIST OF PUBLISHED STANDARDS
Report : 08-0-05 Of 5 LST OF PUBLSHED STNDRDS Total ount: 45 SNS nt pproved mendment SBS/T 07 SNS :00/SPR :00 SNS :009/SPR :009 5. 6. 4.0 4.0 ndustrial, scientific and medical equipment - Radio-frequency
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 VPI Laboratories, Inc. 313 W 12800 S STE 311 Draper, UT 84020 Jason Stewart Phone: 801-495-2310 Email: jasons@vpimfg.com
More informationConducted emission pre compliance measurements
Conducted emission pre compliance measurements All electronic products need to be tested for electromagnetic emissions that may negatively effect the correct operation of other equipment nearby. Electromagnetic
More informationD C 01/2019 3
D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-1 Third edition 2007-06 Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification Commission Electrotechnique Internationale International
More informationNI PXI/PXIe-2529 Specifications
NI PXI/PXIe-2529 Specifications 128-Crosspoint Relay Matrix This document lists specifications for the NI PXI/PXIe-2529 (NI 2529) matrix module. All specifications are subject to change without notice.
More informationTechnical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.
Technical Data Electrocardiograph ECG-1250K This technical data may be revised or replaced by Nihon Kohden at any time without notice. TD.ECG1250_L Specifications ECG input Input impedance: 20 MΩ Electrode
More informationRolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large
Rolyan Splint Pan OPERATION MANUAL Item #081544816 - Small Item #081544808 Large PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW SPLINT PAN. Failure to follow these instructions could result in
More informationIntroduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.
Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides
More informationPressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that
More informationHI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date
Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under
More informationStabilized Differential Relay SPAD 346. Product Guide
Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault
More informationTechnical Specification
Technical Specification 1 Health and Safety Type of Health and Applicable Description safety standard standard Electrical EN 60950 or IEC 60950 Electrical Safety of information technology equipment Radio
More informationDesign Study. Reducing Core Volume in Matrix Transformers
Design Study Reducing Core Volume in Matrix Transformers It is desirable to minimize the volume of a transformer core. It saves weight, space and cost. Some magnetic materials are quite expensive, and
More informationNI PXI-2521 Specifications 40-Channel DPST Relay Module
NI PXI-2521 Specifications 40-Channel DPST Relay Module This document lists specifications for the NI PXI-2521 general-purpose relay module. All specifications are subject to change without notice. Visit
More informationMKH 416 P 48 U. Instruction manual
MKH 416 P 48 U Instruction manual Important safety information Please read this instruction manual carefully and completely before using the product. Make this instruction manual easily accessible to all
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationElectromagnetic Compatibility
Electromagnetic Compatibility TC 16 Annual Report 2015 December 2015 Scope Standardization related to electromagnetic compatibility across the entire frequency spectrum International TCs Shadowed by this
More informationHigh-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime
Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationNI PXI-2520 Specifications 80-Channel SPST Relay Module
NI PXI-2520 Specifications 80-Channel SPST Relay Module This document lists specifications for the NI PXI-2520 general-purpose relay module. All specifications are subject to change without notice. Visit
More informationGeneral Safety/EMC and Electrical Information for i-limb ultra and i-limb digits
1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying
More informationEMC aspects associated to 5G networks
EMC aspects associated to 5G networks ETSI TC-EE/ITU-T SG5 Workshop on Towards Setting Environmental Requirements for 5G Beniamino Gorini 23-11-2017 1 Outline 1. Scenario of present EMC requirements 2.
More informationNI PXI/PXIe-2527 Specifications
NI PXI/PXIe-2527 Specifications 32 1 Relay Multiplexer This document lists specifications for the NI PXI/PXIe-2527 (NI 2527) 32 1 multiplexer relay module. All specifications are subject to change without
More informationNI PXI-2557 Specifications
NI PXI-2557 Specifications 2.5 GHz 75 8 x 1 Multiplexer (SP8T) This document lists specifications for the NI PXI-2557 multiplexer module. All specifications are subject to change without notice. Visit
More informationNI PXI/PXIe-2532 Specifications
NI PXI/PXIe-2532 Specifications 512-Crosspoint, 1-Wire Matrix This document lists specifications for the NI PXI/PXIe-2532 (NI 2532) 512-crosspoint matrix. All specifications are subject to change without
More informationThis is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL ELECTROTECHNICAL COMMISSION CISPR 22 Fifth edition 2005-04 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Information technology equipment Radio disturbance characteristics Limits
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationNI PXI-2530 Specifications
NI PXI-2530 Specifications 128-Channel Reed Relay Multiplexer/Matrix This document lists specifications for the National Instruments PXI-2530 128-channel multiplexer/matrix module. All specifications are
More informationIEC Second Edition
Electromagnetic Compatibility of Medical Electrical Equipment Second Edition Prepared by Mr. James Conrad Presented by Dr. William A. Radasky 1 Second Edition Updates first edition on standards developed
More informationAS/NZS CISPR 14.1:2013
AS/NZS CISPR 14.1:2013 CISPR 14-1, Ed.5.2 2011, IDT Australian/New Zealand Standard Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission
More informationCompany report to support the development of the Ecma MM-EMF technical report (attached pdf-document)
Ecma/TC20/2009/021 DATE CIRCULATION: 2009-04-08 FROM: TO: DOC TYPE: TITLE: AUTHOR: P.A. Beeckman, Philips Applied Technologies Members Ecma TC20-MM-EMF Company report to support the development of the
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12024-06-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 02.06.2017 to 01.06.2022 Holder of certificate: Bureau
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationAustralian/New Zealand Standard
AS/NZS CISPR 11:2011 IEC CISPR 11, Ed. 5.1 (2010) AS/NZS CISPR 11:2011 Australian/New Zealand Standard Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and
More informationPressure transmitter AKS 32 and AKS 33
Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12067-01-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.05.2016 to 19.05.2021 Holder of certificate: EMCCons
More informationLS 120 and ILS 730. Air-gap measuring system LS 120 transducer and ILS 730 signal conditioner
LS 120 transducer and ILS 730 signal conditioner FEATURES» From the Vibro-Meter product line» Contactless measurement for alternators» Electric field principle» No wear-out» 2 to 33 mm measurement range»
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More informationHITEK POWER OL1K SERIES
HIGH VOLTAGE POWER SUPPLY The HiTek Power OL1K Series range of single output high voltage power supplies meets the exacting requirements found in electron and ion beam systems, ion implantation and X-ray
More informationLITZ WIRE 1
www.newenglandwire.com LITZ WIRE www.newenglandwire.com 1 WHAT IS LITZ WIRE? Litz wire consists of a number of individually insulated magnet wires twisted or braided into a uniform pattern with the primary
More informationAS/NZS CISPR 32:2013 AS/NZS CISPR
(CISPR 32, Ed. 2.0:2015, IDT) Australian/New Zealand Standard Electromagnetic compatibility of multimedia equipment Emission requirements Superseding AS/NZS CISPR 32:2013 AS/NZS CISPR 32:2015 This joint
More informationAccr. 002-Test EN-ISO (2005)
Electromagnetic compatibility LAB > Examination of compliance with EMC standards > Measurement of radio-disturbances > Immunity tests > 2004/108/EC EMC Directive > CE Marking > Measurement of electromagnetic
More informationEMC and Variable Speed Drives
EMC stands for electromagnetic compatibility the ability of electric and electronic devices to work properly in the environment for which they are designed. For this purpose the environment is defined
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationA Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards
Fourth LACCEI International Latin American and Caribbean Conference for Engineering and Technology (LACCEI 2006) Breaking Frontiers and Barriers in Engineering: Education, Research and Practice, 21-23
More informationMiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual
FLEXIBLE AC CURRENT SENSOR MiniFlex MF 300-6-2-10 MF 3000-10-2-1 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25
More informationNI PXI-2555 Specifications
NI PXI-2555 Specifications 2.5 GHz Terminated 4 x 1 Multiplexer (SP4T) This document lists specifications for the NI PXI-2555 multiplexer module. All specifications are subject to change without notice.
More informationEarthing for EMC in Installations
Earthing for EMC in Installations Ian McMichael n 1 PQSynergy 2010 Conference Earthing for EMC in Installations Introduction Electromagnetic Compatibility or EMC EMC and installations Standards and References
More informationAmerican National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations
IAS Accreditation Number Company Name Address TL-637 UL Korea, LTD Suwon Laboratory 218 Maeyeong-Ro, Yeongtong-Gu Suwon-Si, Gyeonggi-Do 16675 Republic of Korea Mr. YongJin Suk, Laboratory Manager Contact
More informationSwitched mode power supply for DIN rail mounting type SMP21 DC24V/10A
Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive
More informationCVVOZE Power Laboratories (CVVOZEPowerLab)
CVVOZE Power Laboratories (CVVOZEPowerLab) BRNO, SEPTEMBER 2016 1 Centre for Research and Utilization of Renewable Energy Centre for Research and Utilization of Renewable Energy (CVVOZE) was established
More informationDMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)
DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date
More information400 MHz Passive High-Voltage Probe R&S RT-ZH
Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit
More informationAn Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF
An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF Definition of ElectroMagnetic Compatibility (EMC) EMC is defined as: "The ability of devices and
More informationDevice Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.
/9 TECHNICAL SPECIFICATIONS VOLTAGE LOW-POWER TRANSFORMER VS- Rev. Date Revision Description Prepared by Checked by Approved by 0 24/09/2 First issue A. Peretto L. Peretto 24/06/6 All text review E. Scala
More informationNI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer
NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer This document lists specifications for the NI PXI-2797 terminated multiplexer module. All specifications are subject to change without
More informationAppendix A: Specifications
All specifications apply to the TDS 200-Series Digital Oscilloscopes and a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications, two conditions must first be
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Global Testing Laboratories 3029 E. Gov. John Sevier Hwy. Knoxville, TN 37914-6424 Mr. Craig Baker Phone:
More informationOtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06
OtoRead - Technical Specifications Page 0 Technical Specifications OtoRead D-0116698-A 2017/06 OtoRead - Technical Specifications Page 1 OtoRead TM Configuration Overview The OtoReadTM is available in
More informationPHYSIOFLOW Q-LINK TM
PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...
More informationEnvironmental Exposures to ELF Georg Neubauer
Environmental Exposures to ELF Georg Neubauer 1 Table of Content Environmental exposures to ELF sources Measurement methods Requirements on measurements Conclusions 2 Environmental exposure to ELF sources
More informationMeasuring Technology for Soft Magnetic Materials
Measuring Technology for Soft Magnetic Materials Benefit from the economic efficiency and short amortisation period of BROCKHAUS measuring and testing instruments for magnetic materials. Inline measuring
More informationLaboratory Accreditation Programmes
Laboratory Address PO Box 68307, Newton, Auckland, 1145 47 Mackelvie Street, Grey Lynn, Auckland, 1021 Telephone 09 360-0862 Fax 09 360-0861 URL Authorised Representative Client No. 2218 Programme Accreditation
More informationScrew-in resistance thermometers with plug connector
Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
INTERNATIONAL ELECTROTECHNICAL COMMISSION CISPR 14-1 Edition 4.2 2002-10 Edition 4:2000 consolidated with amendments 1:2001 and 2:2002 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Electromagnetic
More informationCALCULATING RADIOFREQUENCY FIELD STRENGTH SAFETY CODE 6 SITE VALIDATION
CALCULATING RADIOFREQUENCY FIELD STRENGTH SAFETY CODE 6 SITE VALIDATION FOR SITE: W2352 Study conducted by: RF Designer: Henry Phan, P.Eng Henry Phan, P.Eng Report Date: August 19, 2013 Department: Radio
More informationMiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes
FLEXIBLE AC CURRENT SENSOR High Frequency Response for Oscilloscopes MiniFlex MF 300-6-2-10-HF MF 300-10-2-10-HF E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationHuman Exposure Requirements for R&TTE and FCC Approval
Human Exposure Requirements for R&TTE and FCC Approval Derek Y. W. LEUNG Founding and Committee Member of EMC Chapter- IEEE-HK Requirements of Non-Specific Short Range Device (SRD) for CE Marking Radio
More informationPower Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range
SPECIFICATIONS NI PXIe-4610 Power Amplifier This document lists specifications for the NI PXIe-4610 Power Amplifier. These specifications are typical at 25 ºC unless otherwise stated. The operating range
More informationSolid State Relay, 1-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit
More informationNI 2865A 0.3 A Matrix Cards for NI SwitchBlock
SPECIFICATIONS NI 2865A 0.3 A Matrix Cards for NI SwitchBlock This document lists specifications for the NI 2865A matrix relay cards. All specifications are subject to change without notice. Visit ni.com/manuals
More information9 Specifications. Specifications NOMINAL CHARACTERISTICS
9 Specifications Specifications NOMINAL CHARACTERISTICS WARRANTED CHARACTERISTICS Nominal characteristics describe parameters and attributes that are guaranteed by design, but do not have associated tolerances.
More informationTELENOR NETT SPECIFICATION
TELENOR NETT SPECIFICATION Specification no.: A65 Edition: 1 Date/approval: 000518 / Sverre Dag Ljønes Access to programme type digital leased circuits. Specification of the network side of the user-network
More informationWS12EX Position Sensor with Analog output Dust explosion-proof
Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution
More informationSPAD 346 C Stabilized differential relay
SPAD 346 C Stabilized differential relay Stabilized Differential Relay Type SPAD 346 C Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault
More information2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES
2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output
More informationAustralian/New Zealand Standard
AS/NZS 61000.6.4:2012 IEC 61000-6-4, Ed.2.1 (2011) AS/NZS 61000.6.4:2012 Australian/New Zealand Standard Electromagnetic compatibility (EMC) Part 6.4: Generic standards Emission standard for industrial
More informationExposure Level Tester ELT-400
Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various
More informationSERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
International Telecommunication Union ITU-T L.1005 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (02/2014) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE
More informationMDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95
MDC4500-4B Amplifier/Combiner Data Sheet & User Manual February 2016 - Rev 0.95 MDC4500-4B Amplifier IMPORTANT SAFETY and USEAGE INFORMATION Please review the following safety precautions to avoid injury
More informationEMI Installation Guidelines
EMI Installation Guidelines Although Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Interference (EMI), proper installation and wiring methods must be followed
More informationMETRAClip87 and 88 Clamp Multimeters
3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Trafalgar House Trafalgar Close Chandlers Ford Eastleigh SO53 4BW Contact: Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 E-Mail: rob@hursley-emc.co.uk Website: www.emctesting.co.uk
More informationGuidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System
Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationResidual Current Operated Circuit-Breakers (RCCBs)
Product Overview Residual Current Operated Circuit-Breakers (RCCBs) Residual current operated circuit-breakers Number of poles Rated current A Rated residual current ma MW Auxiliary contacts can be mounted
More informationAve output power ANT 1(dBm) Ave output power ANT 2 (dbm)
Page 41 of 103 9.6. Test Result The test was performed with 802.11b Channel Frequency (MHz) power ANT 1(dBm) power ANT 2 (dbm) power ANT 1(mW) power ANT 2 (mw) Limits dbm / W Low 2412 7.20 7.37 5.248 5.458
More informationElectromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)
Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI
More information