Finesse Profiles. Nailstrip
|
|
- Lynn Phelps
- 5 years ago
- Views:
Transcription
1 Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED SHEET LENGTH IS OVER 5 METRES. #10-12 X 25mm WAFER HEAD WOOD 450mm CTS Figure NS ID 004
2 Installation Details: Low Eave/Gutter or Aluminium CD GRADE PLYWOOD 19mm SCREWS TO EDGE OF SHEET NAILSTRIP PANEL RIB CLOSURE PAN TURNED DOWN TO DRIP INTO GUTTER CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. POP RIVET AND SEAL WITH SILICONE. POP RIVET TURN DOWN PAN TO FORM DRIP INTO GUTTER NAILSTRIP SCREWS TO EDGE OF SHEET FASTENERS #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 100mm CTS. MIN 20mm VENTILATION GAP EAVES GUTTER EXT GUTTER BRACKET Figure NS ID 005
3 NAILSTRIP CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. POP RIVET AND SILICONE SEAL PAN TURNED DOWN - 25mm POLE PLATE FLASHING #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 PHILLIPS 100mm CTS. CD GRADE PLYWOOD 19mm WITH ROUTED REBATE MIN 20mm VENTILATION GAP Figure NS ID 006 FASTENER FIX THROUGH TO PLY SUBSTRATE AT MIN 900 C/C 175mm 25mm NOTCHED OVER RIBS BARGE CAPPING NAILSTRIP CD GRADE PLYWOOD 19mm LOW PROFILE FASTENER (BY INSTALLER) FOLD UP END OF SHEET SEE SHEET - TYPICAL STOP END Figure NS ID 007
4 Installation Details: Typical Ridge CD GRADE PLYWOOD 19mm HEX HEAD FIXING FOLD UP END OF SHEET SEE SHEET - TYPICAL STOP END 150 mm 25mm VENTILATION GAP ONE-PIECE RIDGE CAPPING FIX THROUGH TO SUBSTRATE AT MIN 900 C/C TVP C/BOND NAILSTRIP Figure NS ID 008
5 Installation Details: Typical Barge BARGE CD GRADE PLYWOOD 19mm MINIMUM 20mm VENTILATION 40mm BATTEN BARGE FLASHING BARGE Figure NS ID 009 BARGE FLASHING BARGE BARGE CD GRADE PLYWOOD 19mm MINIMUM 20mm VENTILATION Figure NS ID 010
6 Installation Details: One slope ridge TURN UP END PANEL SEE SHEET 2-2 RIDGE CAPPING FASTENER NAILSTRIP FASTENER MINIMUM 20mm VENTILATION GAP Figure NS ID 011
7 Installation Details: Typical Apron Flashing to Wall FOLDED APRON FLASHING WALL STRUCTURE CHASE INTO WALL NEUTRAL SEALANT FOLDED FLASHING 10mm MIN 10mm MIN 40mm BATTEN IF OVER 240mm 150mm MIN CD GRADE PLYWOOD 19mm SCREW Figure NS ID 012
8 Installation Details: Typical Valley Over 7.5 FASTENERS #10-12 X 25mm WAFER HEAD WOOD SCREW W/ #2 100mm CTS. CD GRADE PLYWOOD 19mm WITH ROUTED REBATE C/BOND VALLEY RIB CLOSURE TURNED DOWN MINIMUM 20mm VENTILATION GAP NAILSTRIP PANEL RETURNED EDGE 25mm REBATE PLY Figure NS ID 013 REBATE UNDER VALLEY RIBS VALLEY CENTRE OF VALLEY GUTTER TURNDOWN PLAN VIEW Figure NS ID 014
9 Installation Details: Typical Valley Over 7.5 (cont.) CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. Figure NS ID 015 Installation Details: Typical Valley Under 7.5 PAN TURNED DOWN VALLEY 25mm BYCELL COMPRESSED STRIP NAILSTRIP PANEL RIB CLOSURE CD GRADE PLYWOOD 19mm WITH ROUTED REBATE MINIMUM 20mm VENTILATION GAP Figure NS ID 016
10 Installation Details: Typical Valley Under 7.5 (cont.) GUTTER RIBS VALLEY CENTRE OF VALLEY TURNDOWN Figure NS ID 017 PLAN VIEW Figure NS ID 018
11 Installation Details: Typical Ventilation CUT BACK RIB ON ANGLE. EDGE FOLDED TO CLOSE. NAILSTRIP CD GRADE PLYWOOD 19mm VENTILATION STEELWORK BY OTHERS PURLINS BY OTHERS Figure NS ID 019
12 Installation Details: Typical Panel Turndown 1. Panels requiring field hemmed ends should be fabricated 25mm longer than the finished panel length. Valley conditions must be field cut to the appropriate angle. 2. Cut back panel joints 25mm. 3. Place protruding pan into the panel hemming tool. The front edge of the tool must rest against the notched joint legs on both sides. 4. While maintaining pressure against the panel joints, rotate the hemming tool as close to 90 as possible. AL PANEL TURN-DOWN 25 CUT RIBS BACK 25mm PANEL HEMMING TOOL Figure NS ID 020
13 Installation Details: Typical Stop End 1. Place pan into the panel stop end tool. The front edge of the tool must rest between the ribs. 2. While maintaining pressure against the panel, rotate the stop end tool as close to 90 as possible. 3. Inspect completed bend. OP END STOP END DETAIL PANEL WITH STOP END PANEL STOPEND TOOL Figure NS ID 021
TYPICAL BARGE DETAIL - CROSS SECTION
SELECTED OWENS CORNING ASPHALT SHINGLES APPLY A BEAD OF BITUMASTIC ADHESIVE/SEALANT METAL BARGE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME BARGE BOARD SOFFIT LINING (IF APPLICABLE)
More informationThe Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA
TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low
More informationConstruction details: Master-C type profiles and joints:
Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16
More informationThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST
ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING
More information900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR
900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900
More information900 SERIES WALL PANELS
CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900
More informationPipe penetration refer CT15. Viking CertainTeed Shingles General Roof details
Vented ridge refer CT02 Substrate Viking SuperStrand or F11 Roofing ply Pipe penetration refer CT15 Valley details refer CT07 and CT08 refer CT17 and CT18 for requirements Drip-edge refer CT01 Barge detail
More informationProSnap 100 STANDARD DETAILS
ProSnap 100 OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com
More informationTuff Rib Panel Installation Specifications
Tuff Rib Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. For slopes lower than a 3/12 pitch, lap sealant is suggested on the side laps
More informationREGAL. Installation Manual
REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods
More informationTABLE OF CONTENTS A-1
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE
More informationTable of Contents Light Gauge Metal Roof & Wall Panels
Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools
More informationALPINE TRAY. To get the best from this product please follow these recommendations.
F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please
More information2 ½ Corrugated Panel Installation Specifications
2 ½ Corrugated Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. When using this product butyl lap sealant is recommended for all slopes.
More informationAPRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL
SHEET METAL APRON FLASHING WITH HEMMED EDGE SEALANT SHEET METAL COUNTERFLASHING (SEE NOTE No.1) RAGGLE UNDERLAYMENT TURNED UP WALL SHEET METAL STEP FLASHING SOLDER OR SEAL CORNERS ASPHALT SHINGLES NOTES:
More informationPBR Panel Installation Specifications
4906 St. Stephens Rd. 5780 Hwy 90 W Eight Mile, Al 36613 Theodore, AL 36590 251 456 2254 251 653 1550 251 457 2254(F) 251 653 1514(F) PBR Panel Installation Specifications ROOF APPLICATION: Roof slope
More informationTremLock T-138 INSTALLATION MANUAL T-138 www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013 50 Beth Nealson Drive Toronto, Ontario M4H 1M6 1.800.668.9879 7241 6/8/18 TABLE OF CONTENTS
More informationSLATE & SHINGLE INSTALLATION
EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend
More informationDETAIL MANUAL for Standing Seam / Image II
DETAIL MANUAL for Standing Seam / Image II Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Best Buy Metals Standing Seam Roofing Panels Fig. 2 Standing
More informationTABLE OF CONTENTS A. PBR
TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR
More informationVENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4
ROOF PANEL GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24"
More information400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationBest Buy Metals Toll Free / Phone / Fax
DETAIL MANUAL for Vertical Seam Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Vertical Seam Roofing Panels Fig. 2 Vertical Seam Has 1-3/4" high
More informationHILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING
HILAND TRAY ROOFING I WALLING DESIGN GUIDE FORM AND FUNCTION Hiland Tray is a modern 455mm wide tray roofing and walling system, roll formed onsite with a mobile roll forming facility in long single lengths
More informationGlobal Roofing Solutions Klip-Lok 700
GRS Klip-Lok 700 Global Roofing Solutions Klip-Lok 700 www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Lok 700 GRS Klip-Lok 700 09/18 Typical Specification Materials The roofing shall be Klip-Lok
More informationGlobal Roofing Solutions Klip-Lok 406 Aluminium
GRS Klip-Lok 406 Global Roofing Solutions Klip-Lok 406 Aluminium www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Lok 406 GRS Klip-Lok 406 Alum. 09/18 Typical Specification Materials The roofing
More informationSTRATCO GABLE HOMESHED STRATCO GABLE HOMESHEDS STUBBIE INSTALLATION GUIDE
STRATCO GABLE HOMESHED STRATCO GABLE HOMESHEDS STUBBIE INSTALLATION GUIDE INSTALL GUIDE BEFORE YOU START COUNCIL APPROVAL It is important that you have local council approval before building your Stratco
More informationVENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4
GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24" C/C MAX. BUTYL
More informationTuff-Rib Install Guide
Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.
More informationEuro-Tray Roll Cap. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads
Specific Profile Data Sheet 1 Technical Drawing formats available AutoDesk DWG Format AutoDesk RVT Format PDF Format Euro-Tray Roll Cap Table of Contents General Profile Information 2 Material Specifications
More informationSHED PACK Step 1: Choose your shed type.
SHED PACK Step 1: Choose your shed type. Industrial Shed Open FarmShed Shed Pack / Types of Sheds Drawing # S0104.A001 Hanger Shed =DISCLAIMER= Please read and agree to Purlin Brackets Terms and Conditions
More informationGlobal Roofing Solutions Klip-Tite
GRS Klip-Tite Global Roofing Solutions Klip-Tite www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Tite GRS Klip-Tite 09/18 Typical Specification Materials The roofing shall be Klip-Tite profile,
More informationAssembly instructions
Assembly instructions Plannja Profiles 20 105, 20 75, Sinus 18, Sinus 51, 45, 45R, 19R, 35 including flashings and fittings 2017 Roofing Sheet & Wall Cladding TABLE OF CONTENTS Some words of advice...
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationGlobal Roofing Solutions Brownbuilt
GRS Brownbuilt Global Roofing Solutions Brownbuilt www.globalroofs.co.za marketing@globalroofs.co.za GRS Brownbuilt GRS Brownbuilt 09/18 Typical Specification Materials The roofing / side cladding shall
More informationTalk to us, THE SMART ROOF PEOPLE Visit or Global Roofing Solutions Brownbuilt
Talk to us, THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za Global Roofing Solutions Brownbuilt Typical specification Materials The roofing / side cladding shall be Brownbuilt
More informationKlip-Lok 406 Aluminium
Klip-Lok 406 Alumin GRS Klip-Lok 406 Global Roofing Solutions TM Klip-Lok 406 Aluminium Talk to THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za GRS Klip-Lok 406 GRS Klip-Lok
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More informationDUTCH GABLE FREESTANDING CARPORT
DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If
More informationSteel Roofing & Siding INSTALLATION GUIDE
Steel Roofing & Siding INSTALLATION GUIDE Your Authorized Dealer is: WASHINGTON Auburn (800) 700-7228 WASHINGTON Spokane (866) 321-5954 www.nuraymetals.com CALIFORNIA Redlands (800) 806-8729 CONTENTS BEFORE
More informationKocked Down with Ends Assembled
Installation Instructions for Quarter Round (QR) Kocked Down with Ends Assembled Note: Prior to starting Installation, check unit/parts for damage. Please read entire Installation Instructions & review
More informationSHED PACK. Sheds are commonly constructed using portal frames.
SHED PACK Sheds are commonly constructed using portal frames. This pack relates to purchasing portal frame purlin bracket sets. Ruest our free generic engineered and certified shed plans. SHED PACK Step
More informationExtrusions GB-3-IN01. Updated: Scale: REV: - This Drawing is Protected by Copyright Altus NZ Ltd.
Extrusions Updated: N/A Scale: N.T.S REV: - Dwg Dwg Revision Rev No Description Description Date GB-3-IN01 Index Page - - - - - GB-3-001 Extrusions - - - - - GB-3-002 Extrusions - - - - - GB-3-003 Extrusions
More informationEverbright E610 polycarbonate light panels Installation guidance
Everbright E610 polycarbonate light panels Installation guidance Mono-pitched applications: Eaves For pitched roofs above 0-degree fix aluminium angle EL17 to supporting structure with self drilling screws
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationSpeedZip. Fixing and Handling Guide
Section 1 Delivery/Storing On Site/Handling l SpeedZip is factory or on-site manufactured. l Straight SpeedZip bundles are a maximum 1 tonne, 2 No. sheets nestled and then and placed face to face, banded
More informationTrapezoidal Roof KS1000 RW Installation Guide
Insulated Roof & Wall Panels UK & Republic of Ireland Trapezoidal Roof KS1000 RW Installation Guide Multiple Panels Eaves to Ridge 150mm End Lap September 2018 Trapezoidal Roof KS1000 RW Components Trapezoidal
More informationTable of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8
1 Table of Contents Page(s) Installation Guide for Profile with Hidden Fasteners 3 Installation Steps 4, 5 Prestige Series Moldings 6, 7 Other Accessories 8 Trims & Accessories 9 Eave Starters 10 Gableboards
More informationMINI/MAXI-BATTEN. Panel Information. Detail Conditions. Flashing Profiles
Table of ontents Product Page No. Product Page No. Panel Information Profiles...PMB-2 Panel Overview...PMB-2 Flashing Profiles Eave...PMB- Extended Eave...PMB- leat...pmb- Offset leat...pmb- Starter...PMB-
More informationTHESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
FRKPV-DS-01-MTLH FRKPV-PJ-01-MTLH FRKPV-PJ-02-MTLH FRKPV-PJ-03-MTLH FRKPV-FS-01-MTLH FRKPV-FS-02-MTLH FRKPV-BS-01-MTLH FRKPV-BS-02-MTLH FRKPV-BS-03-MTLH FRKPV-BS-04-MTLH FRKPV-OC-01-MTLH FRKPV-IC-01-MTLH
More informationGlobal Roofing Solutions Klip-Tite
GRS Klip-Tite Global Roofing Solutions Klip-Tite Talk to us, THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za GRS Klip-Tite Typical specification Materials The roofing
More informationBARRELL VAULT BATTENLESS
i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationDW VERTICAL INSTALLATION
AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V
More informationFibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm
More informationInstallation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation
Step 7. Transition s and Accessories Step 3. Valley Step 6. Hip and Ridge Installation Step 2. Rake Trim Step 5. Installing the Shingles Step 1. Eave Starter Installation Step 4. Endwall s Installation
More informationTuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311
Installation Manual Nationwide supplier of quality metal roofing. 65 S. Lee Hwy. Cleveland, TN 7.. www.bestbuymetals.com Toll-Free (800) 78-00 IMPORTANT NOTICE This manual contains suggestions and guidelines
More informationPhone (662) Fax (662) DETAIL MANUAL. and guide to Reed s Metals products
Phone (662) 869-7797 www.reedsmetals.com Fax (662) 869-7799 DETAIL MANUAL and guide to Reed s Metals products Perma-Loc & Secure-Seam Standing Seam Roofing Panels & Accessories -1- Reed s Metals Standing
More informationGuardian warm roof conversion system. Installation Guide
Guardian warm roof conversion system Installation Guide 2 www.guardianroof.co.uk Conservatory walls consist largely of glazed elements including windows and doors that may include structural mullions or
More informationMAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.
PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER
More informationCOMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE
INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia
More informationINSTALLATION GUIDE LEARN MORE AT DECRA.COM
Villa Tile INSTALLATION GUIDE LEARN MORE AT DECRA.COM Table of Contents DECRA Villa Tile Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheet... 3 Codes & Requirements... 3 Roof
More informationSafety Glasses Safety Gloves Ladders Measuring Tape Spirit Level String Line. Tin-Snips Rivet Gun Caulking Gun Silicone Socket Set
BEFORE YOU START Carefully read these instructions and refer to them constantly during each stage of construction. If you do not have all the necessary tools or information, contact Stratco for advice.
More informationFLASHINGS FLASHINGS REVSPEC. Valley Gutter Example V1 V2 V3 V4 V5 V6. Ridge Capping. Low Profile Ridge Capping CUSTOM MADE VALLEY GUTTER
CUSTOM MADE VALLEY GUTTER The Revolution Roofi ng Valley Gutter is used to fi t between two internal roof slopes to prevent the ingress of water into the roof space, it acts as an internal shallow gutter
More information3/ /
SUNGLAZE system is designed for both rafter and purlin construction options. Recommended minimum roof slope for Sunglaze applications is 5 o. Where lower slopes are necessary, we recommend rafter construction.
More informationMANUAL. Perma-Loc & Secure-Seam. Standing Seam Roofing Panels & Accessories. and guide to Town and Country Metals products
DETAIL MANUAL and guide to Town and Country Metals products Perma-Loc & Secure-Seam Standing Seam Roofing Panels & Accessories Town & Country Metals, LLC 10 Progress Parkway Union, MO 63084 Town and Country
More informationTRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT
TRADITIONAL GABLE ATTACHED PATIO AND CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT BEFORE YOU START Carefully read
More informationINTRODUCTION. EqunioxRoof.com. Pro Tip
INSTALLATION MANUAL INTRODUCTION The Equinox Louvered Roof System is designed to be installed in an aluminum frame. All these sections are 1/8" thick extruded aluminum. All engineering for this system
More information401 SW 33rd Ave Ocala, FL
401 SW 33rd Ave Ocala, FL 34474 352-622-1035 www.metalroofingofocala.com Table of Contents Panels...Pg.1 Ultra Rib Trim...Pg.2-4 PBR Trim...Pg.5-6 5V Trim...Pg.7-9 TCM-Lok...Pg.10-11 Insulation/Ventilation:
More informationEnsure there is reasonable access for materials and working space, ensure the shed site is level and consider the disposal of run-off water.
INSTALLATION GUIDE TM Flat Roof Homesheds THE POTTER BEFORE YOU START It is important to check your Local Government Authority requirements before the installation of your new Stratco Potter Flat Roof
More informationTable of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...
Table of Contents DECRA Shake XD Roof Overview.... 2 DECRA Shingle XD Roof Overview.... 3 Introduction... 4 Safety... 4 Tools.... 4 Estimating Sheet... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment...
More informationC.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationKS42 MF SERIES - HORIZONTAL INSTALLATION
CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...
Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...
More informationINSTALLATION DETAILS
INSTALLATION DETAILS Front Issued January 23rd, 2005 These install details are provided to demonstrate the recommended installation method for Metro Roof products and accessories. The details and information
More informationYWY M08 The new VELUX solution
YWY M08 The new VELUX solution VELUX roof windows and vertical window elements installed as a dormer in roof pitches between 42º and 52º YWY M08 is available as a double or triple unit and can be installed
More informationInstallation Manual. This installation is for the Odyssey H1800 Series Ventilation System.
Installation Manual This installation is for the Odyssey H1800 Series Ventilation System. This installation is limited to roofs with pitches between 3 and 35. This instruction assumes that there is a power
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationMULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET
KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV
More informationInstallation guide for 20/20
Introduction The following installation instructions are recommended minimum requirements for the 20/20. The designer and fixer should ensure that tiles are installed in accordance with BS 5534; The British
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationPROVEN DEPENDABLE SUSTAINABLE
B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00 B/SOFFIT
More informationONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S
ONDUVILLA The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S 1 INSTALLATION INSTRUCTIONS Even though ONDUVILLA is easy to install, it is important to read through these
More information1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Steep-Slope Roof Systems
More informationThis installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format.
1.00 - Introduction This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format. Please note, each roof has been individually designed to meet specific
More informationUL Construction No. 254
UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide
More informationROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION
ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building
More informationPRODUCT EVALUATION Effective July 1, 2009 RC-204
TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective
More informationDECRA Shingle Installation Guidelines
Installation Guide DECRA Shingle Installation Guidelines General Instructions Failure to use these guidelines may void the product warranty. Local building codes may require additional application techniques
More informationMetroCOTTAGE Shingle
Batten-less Installation Sept. 14, 2017 INSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories. used in the United
More informationAustin Standing Seam Awning Assembly and Installation Instructions. Assembly Instructions
Austin Standing Seam Awning Assembly and Installation Instructions Be sure to use safety glasses when assembling and installing the awning. Some metal parts may have sharp edges. Use work gloves to handle
More informationDMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988
FP CLIP 24" O.C. MAX B/SOFFIT 5 1/2" SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR15-V-01-00
More informationOWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS
General This Installation Instruction document for Owens Corning asphalt roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with the
More informationShingle Installation Guide
Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors
More informationINSTALLATION GIUDE.
INSTALLATION GIUDE INTRODUCTION The instructions and drawings included here are intended only as a guide for the installation of ECO Roofing Systems Spanish and Modern profiles. The materials and methods
More informationBarrel Vault Counter Batten and Batten
Barrel Vault Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationTYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS
TYPICAL AND PATTERNS FOR MAX-RIB S MAX-RIB (PATTERN #1) @ 1'-8" O.C. (MAX.) ROLL TAPE SEALANT @ SEAMS MAX-RIB @ 1'-8" O.C. (MAX.) ROLL TAPE SEALANT @ SEAMS MAX-RIB TRIM (PATTERN #3) NOTE: TAPE SEALANT
More informationMasterRib. Installation Manual. July Toll-Free (888) MTL-ROOF. PO Box 229 Fayetteville, NC Rev.
MasterRib Installation Manual July 010 PO Box 9 Fayetteville, NC 80.. www.unionmetalroofing.com Toll-Free (888) MTL-ROOF Rev. 7/10 IMPORTANT NOTICE This manual contains suggestions and guidelines on how
More informationNutec Bigsix Roofing Accessories
Nutec Bigsix Roofing Accessories Nutec Bigsix Close Fitting Adjustable Ridge Capping (Grey) Adjustable for 0º - 0º pitches 70-000 87 mm 70-00 87 mm Nutec Bigsix Close Fitting Adjustable Ridge Capping (Terracotta)
More information