Load-carrying capacity of timber frame diaphragms with unidirectional support

Size: px
Start display at page:

Download "Load-carrying capacity of timber frame diaphragms with unidirectional support"

Transcription

1 Load-carrying capacity of timber frame diaphragms with unidirectional support Jørgen Munch-Andersen, Danish Timber Information, Introduction The rules for determining the load-carrying capacity for roof, floor and wall diaphragms is usually only dealing with cases where each panel is supported by timber frame or noggins along all edges. The conventional plastic model with a hold down at the end appears as Model A in Eurocode 5. This paper proposes a simple plastic model for cases where all supports are in one direction. It is justified for walls using tests results from Källsner (1983) who measured the racking load carrying capacities for shear walls with different support conditions and panel types. It is also shown how the model can be used for roof and floor diaphragms. Fully supported panels Figure 1 illustrates the case covered by Method A in Eurocode 5 (section 9.2.4). It is a plastic method based on the assumptions that all edges are supported by the timber frame and that all forces between panels and timber frame are parallel to the edges of the panels. Further, it is presupposed that the bottom rail can transfer the horizontal F v load to the support and that there is a hold down at the end to withstand the vertical reaction Ft = H/ B. When the load on each fastener is F f, the fastener spacing along the edges is s and the effective number of fasteners along the horizontal edges is defined as n x = b/s and along the vertical edges as n y = h/s equilibrium of a panel then requires n x F f h = n y F f b. This is seen to be fulfilled when the fastener spacing is the same along all edges. The definition of the effective number of fasteners implies that the fasteners in the corners are assumed to take the load ½ F f in both the horizontal and the vertical direction. (The fasteners in the intermediate studs are only used to prevent buckling so the fastener spacing there can be larger than s). Figure 1. Shear wall where all edges are supported, as presupposed in Eurocode 5. 1

2 When the lateral load carrying capacity of each fastener is R f the racking load-carrying capacity of one panel becomes R = nr = bsr / (1) ' v x f f The racking load carrying capacity of a diaphragm with several panels supported along all edges can be determined by replacing the dimensions of the panel (b and h) with the dimensions of the diaphragm (B and H) so R v = BsR / (2) f Limitations In order to prevent buckling of the panels Eurocode 5 requires for fully supported panels that a net /t < 100 where a net is the inner distance between studs and t is the thickness of the panel. Eurocode 5 also prescribes that the racking load carrying capacity for narrow panels should be reduced by the factor bh / / bh 4 bh / < 2 c = 2/ hb 2 < bh / 4 < > 1 0 bh / 4 or bh / 4 The reason is presumably that for a given rotation of a narrow panel the displacement of the short edges along the top and bottom rails becomes much larger than the displacements of the long edges along the vertical studs. This means that is not reasonable to utilize the full load carrying capacity of the fasteners in both directions at the same time. (3) Unidirectional supported panels Panels not supported along the internal vertical edges but only along intermediate horizontal rails, as shown in Figure 2, are hereinafter referred to as Unidirectional supported panels. The model in this section deals with a shear wall as in Figure 2. Figure 3 illustrates how the load is assumed to be distributed over the fasteners. The fasteners within the length e at each horizontal rail are attributed to take the vertical force. The forces will act perpendicular to the rails but forces perpendicular to the edges of the panel only occurs along part of the top and bottom rails. The vertical load taken by the fasteners at the top and Figure 2. Shear wall which internally is only supported by horizontal rails. 2

3 bottom rail is assumed to be only half of the load taken at the fasteners at the intermediate rails. For a configuration like in Figure 2 and 3 the effective number of fasteners to take up the vertical load along one edge becomes n y h e 1 1 e = + + a s s where the first term is the number of nails within distance e in the intermediate rails and the second term is half of the nails within e along the top and bottom rail (half because they are assumed only to carry half load). (4) Figure 3. Load distribution over the fasteners in an intermediate panel of a shear wall with internal horizontal rails. The horizontal load is taken by the fasteners along the top and bottom rails, but those fasteners partly used to take vertical load are assumed to take only half of the others. The effective number of fasteners to take the horizontal load along one edge is then n = ( b e)/ s x As the lever arm for the vertical forces is (b e) equilibrium requires n F h= n F ( b e) (6) x f y f Inserting (4) in (5) gives the relation n y = h/s. The value of e which ensures equilibrium can be determined from (3) when n y is substituted by h/s as ha ( ss ) 2 e = ( h a) s+ as 2 Obviously e is limited by b/2. In order to ensure that the deformation at all fasteners within e is sufficient to develop the plastic load carrying capacity R f the distance e must be limited. Based on the test results discussed below it is found that the limit should be e 0,35 b. When the limit becomes effective n y will be too small to use all n x fasteners in the horizontal direction. The load carrying capacity should therefore be calculated using the effective spacing of the fasteners hs / when e 0,35b sef = hn / y, ny = As per Eq.(4) when e= 0,35b The panel will then act as a panel with height h, width (b e) and fastener spacing s ef. The racking load carrying capacity of one panel is then (5) (7) (8) 3

4 R = nr = ( b e)/ s R (9) * v x f ef f The racking load-carrying capacity of a diaphragm with several panels as in Figure 2 can be determined as B * B e Rv = Rv = R f 1 (10) b s b ef The horizontal rails shall transfer the vertical load across the joint between two panels. The load is anti-symmetric as illustrated in Figure 3 which means that the moment is nil at the joint. The imum shear force in the rail occurs at the joint. In the intermediate rails equilibrium requires e V +1 b= Ff ( e b s ) or 2 e e V +1 F = f 1 s (11) 2 b where (e/s 2 + 1) is the number of fasteners within the distance e. The imum moment in the rail becomes M e e s2 V b b where the term (1 s 2 /b) is an approximate but very accurate correction from uniformly distributed load to discrete loads with spacing s 2. It occurs usually at the second fastener from the joint. If the rail has to be joined within a diaphragm the best place is at the middle of a panel where the moment is nil and the shear force is V mid = V e/(b e). Experimental justification Källsner (1984) has carried out numerous tests with timber framed shear walls clad with different types of panels and with different configurations of the frame. The tests are carried out with a vertical hold down at one end of the wall so the tests reflect the assumptions for Method A in Eurocode 5. All panels were mm and most tests were carried out with standing panels on a frame with continuous top and bottom rail and vertical studs spaced 600 mm apart, see type i in Figure 4. The timber was 50 mm wide and the walls were mostly 2 or 3 panels wide. The types of panels use here were 13 mm gypsum board fastened with 4 38 mm gypsum screws 13 mm bitumen impregnated soft fiberboard fastened with 1,9 35 mm round nails 9 mm gypsum board (tested at 90 % RH) fastened with 2,5 35 mm clout nail For these types of panels tests were also carried out with the panels fixed to horizontal rails in the form of mm battens per a = 600 mm. The battens were mounted onto the frame used for type i. Both configurations with standing (type ii) and lying (type iii) panels has been investigated, see Figure 4. Note that for type ii and iii b and B is the dimensions along the rail and h and H the dimensions perpendicular to the rails. Results from type i tests are shown in Table 1. From the measured racking load carrying capacity R v,obs the lateral load-carrying capacity R f of the fasteners are found from (1) in accordance with Method A in the Eurocode. The values also agree very well with the capacities measured by Källsner directly in a testing machine. Tests with 13 mm gypsum boards were carried out with both 1, 2 and 3 panels. It is seen that the fastener load carrying capacity R f at failure is very similar for the four tests. The mean value 0,753 kn is used henceforth. The coefficient of variation is as low as 2,6%. For the 9 mm gypsum board two different fastener spacing have been used. It appears that halving the spacing does not double the failure load. The observations about fracture at failure given by Källsner indicate that the small spacing causes rupture in the panel at numerous fasteners not only at the corner fastener. This explains the apparent reduced failure load of the fastener when spaced only 50 mm. This value is not used henceforth. (12) 4

5 Type i: Supported 4 sides Type ii. Horizontal support, standing panels Figure 4. Definition of wall types and geometry. Type iii. Horizontal support, lying panels Table 1. Results for type i walls (Källsner, 1984). The lateral load-carrying capacity R f of the fasteners are back calculated according to Eq. (1). Panel type 13 mm gypsum boards Soft fiber 9 mm moist gypsum boards board Test no U1 U2 No of panels B, mm H, mm s, mm R v,obs, kn 4,59 4,52 8,71 13,84 16,71 9,72 17,98 R f, kn 0,765 0,753 0,726 0,769 0,348 0,405 0,375 Results for wall type ii and iii are given in Table 2. The fastener load carrying capacity R f is taken from Table 1. From the last row in Table 2 it is seen that the model predicts the measured racking load-carrying capacity quite well, except for Test no U6 in the last column. In that test the panels is reported to bulge severely and the bending stress σ m in the batten is very high. Further, the load V at the end of the batten is so high that it would require more than one fastener to withstand it. It is not specified by Källsner how this connection is made, but it is most likely by only one fastener. For practical design the cases represented by Test U6 would be ruled out because the horizontal rail could not be proven to be strong enough, so Test U6 is disregarded in the evaluation of the model. Figure 5 shows the observed versus the estimated values of R v for the other tests. The slope 0,975 indicates that the model on average overestimates R v by 2,5 %. The coefficient of variation of R v,est /R v,obs is only 6,4 %. These small values describes the model uncertainty and can easily be covered by a model modification factor of 0,9 applied to the estimated load carrying capacity. There is no sign of the model error being dependent on the type of panel, the orientation of the panels (type ii or type iii) or the fastener type. It also works for different ratios of fastener spacing in the outer and in the intermediate rails, as long as the load carrying capacity of the rails and their fastening at the end is sufficient. The three types of panels used have all a quite small stiffness and some bulging has been reported by Källsner. This might be assumed to decrease the load capacity. Using a stiffer panel like plywood is expected to reduce the bulging so the higher capacity of the fasteners in such materials can safely be used, especially when the unsupported edges are fitted with tongue and groove. 5

6 Table 2. The observed and estimated racking load carrying capacity for wall type ii and iii. Wall type ii iii Panel type (Equation no.) 13 mm gypsum Soft fiber board 9 mm moist gypsum boards Soft fiber board 9 mm moist gypsum boards Test no U3 U4 23 U5 U6 No of panels R f, kn 0,753 0,348 0,405 0,405 0,348 0,405 0,405 H, mm B, mm h, mm b, mm a, mm s, mm s 2, mm R v,obs, kn 6,96 4,12 5,37 10,00 7,03 8,05 10,67 e, mm (7) e 0,35b, mm n y (4) 10,3 18,0 20,8 37,6 16,0 12,0 24,0 s ef, mm (8) R v,est, kn (10) 7,56 4,07 5,48 9,90 7,89 7,70 14,99 V, kn (11) 1,18 0,86 1,37 2,47 1,40 1,92 3,75 M, knm (12) 0,120 0,103 0,171 0,324 0,325 0,365 0,778 σ m, MPa * 5,8 4,9 8,2 15,5 15,6 17,5 37,3 R v,est /R v,obs 1,09 0,99 1,02 0,99 1,12 0,96 1,40 σ m is the bending stress in the 50 x 50 mm rails from the moment M R_v,obs, kn R_v,est, kn Figure 5. The observed versus the estimated load carrying capacity for the tests in Table 2 excluding Test U6. The slope of the best fit straight line through the origin is 0,975. 6

7 Applications In the following the use of the model for shear walls, flooring and roofing is illustrated. It is assumed that the fastener spacing is similar along all rails so s 2 = s. It is quite advantageous for the load carrying capacity and the equations become much simpler. The estimated load carrying capacity R v should be reduced by the model modification factor 0,9. Similarly, V and M ought to be increased by 1/0,9 because the model uncertainty might mean that the distribution of the load on the rails are not quite as assumed. This is not included in the examples in the following. Simplification for s 2 = s Equations (4) becomes n y h e = + 1 a s Equation (7) reduces to e= a s 0,35b (7a) and (8) to s ef a = es / + 1 Finally (8a) into (10) gives an equation independent of s ef, so only e needs to be determined from (7a) B e Rv R e = f a s b (4a) (8a) (10a) By means of (10a) with the capacities R v and R f replaced by the forces F v and F f (11) is reduced to a V = F a t B = H (11a) where the latter term is obvious because H/a is the effective number of rails, each contributing by V to the reaction F t (the top and bottom rail contributes by ½ V ). Limitations In order to prevent buckling of unidirectional supported panels the requirement to the thickness in Eurocode 5 should be tightened to a net /t < 50. This conforms with that the 9 mm gypsum panels in Table 2, which has the ratio 550/9 ~ 60 were reported to bulge severely in some cases, so they ought to be excluded from the design rule. The reduction of the racking load carrying capacity for narrow panels in Eurocode 5 represented by the factor c in (3) should for unidirectional supported panels be applied to e. This will ensure the same minimum displacement for a narrow panel as for a full panel as used in the tests. (7a) therefore becomes ca ( s) e = min c0,35b (7b) End panels If the horizontal rails are supported at the ends such that the load V can be transferred to a structure behind the end panels (first and last panel) will act like an intermediate panel as described above. Another and usually quite simple possibility is to fix the outer vertical edge of the end 7

8 panel to a vertical stud as shown in Figure 6. This solves the problem that the load V might be so high that it is difficult to transfer it from the rail to another structure by a simple connection. Figure 6. Unidirectional supported shear wall with vertical studs at the ends. This reduces the need for fastening the ends of the rails to the structure behind the rails. Example 1: Shear wall A wall consisting of four panels as in Figure 7 is considered. The input parameters are: R f = 0,25 kn. H = 2400 mm B = 4800 mm h = 1200 mm b = 2400 mm a = 600 mm s = 100 mm Figure 7. Shear wall with panel length parallel to the support. 8

9 The necessary calculations become: Eq. (3): b/h = 2 => c = 1 Eq. (7b): e = 1 ( ) = 500 mm Eq. (10a): R v = 0, = 9,50 kn If the load is F v = 8 kn the rails should withstand 600 Eq. (11a): V = 8 = 1,00 knand Eq. (12): M = 1, = 190 knmm = 0,19 knm Example 2: Roof diaphragm (wind bracing) When for example plywood is used on roofs the panels will usually be supported only by the rafters as shown in Figure 8. Plywood panels mm are placed across the rafters.this diaphragm can be used to bring the wind load q on the upper part of the gable wall down to the head beam on the façade. The line load, which here is assumed to be triangular, can be replaced by a concentrated load at the centre of gravity for the distributed load. It is seen that the configuration in principle is the same as in Figure 2, except that the rails are turned 90 and the external load is acting perpendicular to the support and therefore becomes F t. The distance from the gravity centre to the head beam becomes B and the length of the roof becomes H. The load carrying capacity should therefore be determined as H Rt = Rv (13) B where R v is determined from (10a). q Ft s h H=l B b a Ft Rafter Head beam Figure 8. Roof slab with panel length across the supporting rafters. The slab supports the gable wall for wind load. 9

10 The input parameters are: R f = 0,5 kn H=l = 5600 mm B = 2400 mm h = 2400 mm b = 600 mm a = 800 mm s = 75 mm The necessary calculations become: Eq. (3): b/h = ¼ => c = ½ Eq. (7b): e = ½ 0, = 105 mm Eq. (10a): R v = 0, = 2,97 kn Eq. (13): R t = 2,97 = 6,93kN 2400 If the load is F t = 6 kn the rafters should withstand 800 Eq. (11a): V = 6 = 0,86 knand Eq. (12): M = 0, = 46 knmm = 0,046 knm Each rafter must be fastened to the head beam for V. Some blocking will be needed to prevent torsion. The moment in the rafters is seen to be negligible. The reactions F v should be transferred to the gable walls. When the panels are staggered some panels will be smaller than the full panels. There is no reason reduce the capacity due to the smaller panels because value of c is higher for the panels with reduced h and therefore has a higher load-carrying capacity per length. It is probable that the staggering causes other mechanisms, e.g. contact forces and bending, to contribute to the load-carrying capacity for narrow panels. Using these effects requires another model and experimental verification. Example 3: Floor diaphragm Timber panels laid across floor beams can enable a timber floor to transfer wind loads on the facades to transverse shear walls. Figure 9 shows the same structure as Figure 8, but the wind load is represented by the line load q. The floor can be regarded as two virtual unidirectional supported shear walls rotated 90 when cut into halves. The line load is converted to two concentrated forces acting at distance H = l/4 from the ends. The edge beam shall be able to transfer F t between the two virtual walls. The input parameters for each virtual wall are: R f = 0,5 kn H = l/4 = 1400 mm B = 3600 mm h = 2400 mm b = 600 mm a = 800 mm s = 75 mm 10

11 Edge beam Ft s a B l h H=l/4 b Ft H q Figure 9. Floor diaphragm which supports the facade for wind load. The necessary calculations become: Eq. (3): b/h = ¼ => c = ½ Eq. (7b): e = ½ 0, = 105 mm Eq. (10a): R v = 0, = 4, 45 kn If the line load is q = 1,4 kn/m the concentrated load on each virtual wall is F v = ½ 1,4 5,6 = 3,92 kn. The floor beams should withstand 800 Eq. (11a): V = 3,92 = 0,87 kn and Eq. (12): M = 0, = 47 knmm = 0,047 knm The edge beam shall transfer 1400 Eq. (13): F t = 3,92 = 1,52 kn 3600 F t could also be obtained directly as Ft = ql / B= 1,4 5,6 /3,6= 1,52kN Conclusions A model is developed to estimate the racking load carrying capacity of timber framed diaphragms when the panels are only supported in one direction Unidirectional supported panels. The model is plastic (as the model for fully supported panels in Eurocode 5) and is based the load distribution on the fasteners shown in Figure 10. The load along the unsupported edges is supposed to be transferred by the nails within the distance e from the edge. It is important that the shear force V can be sustained by the supports and transferred to a structure behind at the ends. 11

12 Figure 10. The assumed load distribution on the fasteners for a unidirectional supported diaphragm. The model agrees very well with a comprehensive test series carried out by Källsner (1984) when the load carrying capacity of the fasteners is determined from tests with fully supported panels. The model becomes quite simple when the fastener spacing is the same in all supports (s = s 2 ). The racking load carrying capacity R v can for non-narrow panels be estimated as B e e Rv R = f a s b where: e= a s 0,35b R f is the load carrying capacity of the fasteners s is the fastener spacing B is the width of the diaphragm, along the supports b is the width of each panel, along the supports a is the distance between the supports (c-c) The shear force becomes V = a B The model can be used for both shear walls, roofs and floors sheathed with panels. In order to compensate for minor model uncertainties it is recommended to reduce the racking load carrying capacity by 10 %. The tests concerns rather soft panels but using a stiffer panel like plywood is expected to reduce the bulging so the higher capacity of the fasteners in such materials can safely be used. Tongue and groove along the unsupported edges will further reduce the bulging. It is also recommended to reduce the capacity of narrow panels (width to length ratio smaller than 1:2) similarly to Eurocode 5. This reduction compensates for the quite different translation at the fasteners in the length and width direction of the panel. References Källsner, B: Panels as wind-bracing elements in timber-framed walls (in Swedish). TräteknikCentrum, Stockholm, (Träteknik Rapport Nr 56). Eurocode 5: Design of timber structures - Part 1-1: General and rules for buildings. CEN

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls Building 1 Grosvenor Court, Hipley Street OLD WOKING, SURREY GU22 9LL Tel: +44 (0) 1483 769518 Fax: +44 (0) 1483 770863 E-mail: design@silvatecdesigncom Internet: wwwsilvatecdesigncom The Influence of

More information

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side ITEM 1 DESCRIPTION OF BUILDING ELEMENTS Blocking between joists or rafters to top plate, toe 2 Ceiling joists to plate, toe 3 4 5 6 Ceiling joists not attached to parallel rafter, laps over partitions,

More information

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM J A Wium Institute of Structural Engineering 19 November 2007 ISI2007-3 TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR

More information

Vertical Offset Base and Safety Rail System Installation Instructions

Vertical Offset Base and Safety Rail System Installation Instructions Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat

More information

Glued laminated timber beams repair.

Glued laminated timber beams repair. Glued laminated timber beams repair. Master s Degree Extended Abstract Ricardo Cardoso Henriques da Silva Keywords: glulam, delamination, self-tapping screw, plywood, repair November 2014 1. INTRODUCTION

More information

SINTEF Building and Infrastructure. Contents

SINTEF Building and Infrastructure. Contents Contents Contents... 2 1. Introduction... 3 2. Test Object... 3 3. Test Method... 4 4. Testing... 5 4.1 Hunton Asfalt Vindtett 12 mm... 5 4.2 Hunton Bitroc 15 mm... 5 4.3 Hunton Asfalt Vindtett 25 mm...

More information

EXAMPLE 1-4 EXAMPLE 1-5

EXAMPLE 1-4 EXAMPLE 1-5 EXAMPLE 1- Calculate the maximum shear stress τmax in a simply supported wood beam carrying a uniform load of (w=18 kn/m) if the length is 1.75 m and the cross section is rectangular with width 150 mm

More information

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY August 10, 2010 T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY ST - T-BRACE 2 R MiTek Industries, Chesterfield, MO Page 1 of 1 Note: T-Bracing / I-Bracing to be used when continuous lateral bracing is impractical.

More information

3.1 General Provisions

3.1 General Provisions WOOD FRAME CONSTRUCTION MANUAL 107 3.1 General Provisions 3.1.1 Prescriptive Requirements The provisions of this Chapter establish a specific set of resistance requirements for buildings meeting the scope

More information

European Technical Assessment ETA-13/0029 of 11/07/2017

European Technical Assessment ETA-13/0029 of 11/07/2017 ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1 Wood structures Copyright G G Schierle, 2001-02 press Esc to end, for next, for previous slide 1 Wood Types: Balloon framing (rare) Platform framing Heavy timber framing Advantages: The only renewable

More information

STRUCTURAL TIMBER DESIGN

STRUCTURAL TIMBER DESIGN STRUCTURAL TIMBER DESIGN to Eurocode 5 2nd Edition Jack Porteous BSc, MSc, DIC, PhD, CEng, MIStructE, FICE Director lack Porteous Consultancy and Abdy Kernlani BSc, MSc, PhD, CEng, FIStructE, FIWSc Professor

More information

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Korean standards of visual grading and establishing allowable properties of softwood structural lumber Korean standards of visual grading and establishing allowable properties of softwood structural lumber Park, Moon-Jae 1, Shim, Kug-Bo 1 ABSTRACT Korean standards related to wood products such as "Sizes

More information

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)? Mobile County Public Works Residential Plan Reviewers Checklist For Structural Requirements of Wood Framed Residences Recommendation: Permit as Noted Revise Plans and Resubmit MCPW Ref. No. Design Criteria:

More information

GlasRoc Sheathing Type X

GlasRoc Sheathing Type X Wall / Fire-Rated Systems 3-5/8" (92 mm) Steel Studs ProRoc Steel Stud System 3-5/8" (92 mm) Steel Track 3-1/2" (89 mm) Glass Fiber or Mineral Wool Insulation GlasRoc Sheathing Type X UL Design U465 Cavity

More information

Chapter 33: Lofts (Or Second Floors)

Chapter 33: Lofts (Or Second Floors) Chapter 33: Lofts (Or Second Floors) Most Common Mistakes: 1. Designing loft yourself and installing later. 2. Inadequate height either below or above. 3. Not enough headroom for stairs. 4. Failure to

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA The SIMPLE FRAMING SYSTEMSM INSTALLATION GUIDE USA for Floors This Installation Guide is intended to provide general information for the designer and end-user. For further information, please refer to

More information

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

2x6. 2x8. 2x10. Size. 2-2x10 8'-5 w/ 2 NJ 7'-3 w/ 2 NJ 1 Rafter Size Spacing Allowable span 24" 11'-9" 24" 2x6 14'-1" 2x4 12" 15'-6" 12" 24" 14'-10" 24" 2x8 18'-2" 2x6 12" 20'-5" 12" 24" 18'-2" 24" 2x10 22'-3" 2x8 12" 25'-8" 12" 24" 21'-0" 24" 2x12 25'-9"

More information

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam LVL8 H1.2 GENERAL FRAMING Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam NPIL/MARCH2015 Introduction to NelsonPine LVL8 H1.2 NelsonPine LVL is an engineered wood composite made from rotary peeled

More information

JOIST DETAILS Plate nail, 16d (0.15" x 1 ") at 1 on-center Blocking panel: 1 1 8" TJ Rim Board, 1 1 TimberStrand SL or TJI joist Toe nail, 10d (0.11" x ") at on-center A1 CS BEAM DETAILS L1 eb stiffener

More information

APA Performance Rated Rim Boards

APA Performance Rated Rim Boards D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1 Kug-Bo Shim* Research Scientist Department of Forest Products Korea Forest Research Institute Seoul, 130-712, Korea Ronald W. Wolfe General

More information

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame BUILDING THE BASIC SHED Step A: Build the Foundation & Floor Frame 1. Excavate the building site and add a 4" layer of compactible gravel. If desired, add an extension to the base for the optional wood

More information

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor F. Moshiri, C. Gerber, H.R. Valipour, R. Shrestha & K.I. Crews Centre for built infrastructure,

More information

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans 12 X 8 Shed Plans With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans Blueprints And Diagrams Instructions For Building The Shed

More information

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings Eurocode EN 1993-1-1 Eurocode 3: 3 Design of steel structures Part 1-1: General rules and rules for buildings Eurocode EN 1993-1-1 Eurocode 3 applies to the design of buildings and civil engineering works

More information

Recommended Slating Tools

Recommended Slating Tools Recommended Slating Tools Product Size L Sketch of Article No. Description 60-070 Scriber 60-00 Slater s Hammer 60-00 Slater Ripper 60-080 Parallel Shears 60-0 Slate Cutter Kwiksnip Slate Guuillotine Slate

More information

EzyBrace For Light Steel Frame Systems

EzyBrace For Light Steel Frame Systems EzyBrace For Light Steel Frame Systems Systems for use with light steel framing have been updated in March 2017 to offer improved simplicity and efficiency. Key changes include: CORNER FASTENER PATTERNS

More information

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language. European Technical Assessment ETA-16/0902 of 17 March 2017 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction

More information

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6 Chapter 6 WOODEN BUILDINGS 6.1 INTRODUCTION Wood has higher strength per unit weight and is, therefore, very suitable for earthquake resistant construction. But heavy cladding walls could impose high lateral

More information

Exterior Wall Fastener Schedule

Exterior Wall Fastener Schedule City of Republic Community Development Department Exterior Wall Fastener Schedule REVISION DATE: JANUARY 2017 Design and construction (2012 IRC Section R602.3): Exterior walls of wood frame construction

More information

APPLICATION FOR A BUILDING PERMIT

APPLICATION FOR A BUILDING PERMIT APPLICATION FOR A BUILDING PERMIT City of San Jacinto 595 S. San Jacinto Ave San Jacinto CA 92583 95.487.7330 fax 95.654.9896 Must print legibly, submit (3) sets of building and plot plans. Fill out all

More information

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS A - INTRODUCTION This report addresses engineered design for unblocked wood structural panel (plywood or OSB) roof diaphragms with either continuous

More information

Featuring TJ Rim Board and TimberStrand LSL

Featuring TJ Rim Board and TimberStrand LSL #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load

More information

Wall Form Design Part I

Wall Form Design Part I Wall Form Design Part I Lecture 3 Bearing or rushing Bearing Stresses (ompression Perpendicular to the Grain) Allowable stresses for compression perpendicular to the grain are available from tables providing

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

Investigation on role and function of noggings in residential timber frame construction

Investigation on role and function of noggings in residential timber frame construction Investigation on role and function of noggings in residential timber frame construction W. Karunasena Centre of Excellence in Engineered Fibre Composites, Faculty of Engineering and Surveying, University

More information

Clopay Models 835/837 Sliding Door System Installation Guide

Clopay Models 835/837 Sliding Door System Installation Guide Clopay Models 835/837 Sliding Door System Installation Guide The aim of this instruction is to guide you through the process of construction and fitting of Sliding Doors. Due to the number of sizes available

More information

A Shell construction

A Shell construction A Shell construction A 4/2012 Content 1 BASE AND WALL ANCHORING 1.1 Base with mortar bed 1.2 Base with sill plate 1.3 Base with raised sill plate 1.4 Concrete base (mortar bed) 1.5 Concrete base (sill

More information

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes Missouri University of Science and Technology Scholars' Mine International Specialty Conference on Cold- Formed Steel Structures (2014) - 22nd International Specialty Conference on Cold-Formed Steel Structures

More information

Shingle Installation Guide

Shingle Installation Guide Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors

More information

BRACING BRACING SECTION 7 SECTION 7

BRACING BRACING SECTION 7 SECTION 7 If we are to learn from the past, it is clear that there is generally a lack of understanding of the purpose of roof bracing and who should be responsible for it. This has led to disputes, claims and,

More information

Nailed Structural-Use Panel and Lumber Beams

Nailed Structural-Use Panel and Lumber Beams D A T A F I L E Nailed Structural-Use Panel and Lumber Beams When roof load or span requirements are too great to allow use of commonly available dimension lumber or timbers, a box beam constructed of

More information

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

LEGACY REPORT.  (800) (562) A Subsidiary of the International Code Council. *Revised September 2003 ICC-ES Evaluation Report ER-580* Reissued January 00 www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council Legacy report on the 997 Uniform Building Code DIVISION: 05

More information

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading Haller, Peer 1 SUMMARY Nailed laminated timber elements are used in housing construction for floor,

More information

Joshua Woodsman

Joshua Woodsman CONSTRUCTION GUIDE of one of our design Please Note This electronic document is protected by the identifier against unauthorized dissemination on the Internet. Before building any structure make sure you

More information

Structural Criteria for Residential Flush-Mounted Solar Arrays

Structural Criteria for Residential Flush-Mounted Solar Arrays Structural Criteria for Residential Flush-Mounted Solar Arrays Planning and Development Building & Safety Division 1. ROOF CHECKS A. Visual Review/Contractor s Site Audit of Existing Conditions: 1) Is

More information

*Revised September 1, 2003

*Revised September 1, 2003 LEGACY REPORT ER-580* Reissued January, 00 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 560 Workman Mill Road, Whittier, California 9060 # (56) 699-054 Regional Office # 900 Montclair

More information

Installation Guidelines

Installation Guidelines Installation Guidelines Tando Building Products provides these instructions as general guidelines only. Tando Building Products neither installs exterior cladding nor has any control over any installation.

More information

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7 www.garyklinka.com page 1 of 16 Truss Joist I-Joist Quiz Instructions: www.garyklinka.com 1. Print these pages. 2. Print referencing manual from my site at http://garyklinka.com/manuals/tj-4000.pdf or

More information

FASTENERS BUILDING DEPARTMENT

FASTENERS BUILDING DEPARTMENT FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and

More information

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel This 8 12-ft. shed features a simple gable roof, double doors, and side and rear windows for natural lighting. With full-height walls and doors, there's ample room for storing large items or creating a

More information

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE U.S. Technical Guide U.S. TECHNICAL GUIDE LP SolidStart LVL & Header Technical Guide 2900F b -2.0E Please verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior

More information

Lightweight purlins. Technical Manual.

Lightweight purlins. Technical Manual. CFI.001E/08.2011/PR Ruukki is a metal expert you can rely on from start to finish, when you need materials, components, systems or total solutions. e continuously develop our operating model and product

More information

VERSA-LAM. An Introduction to VERSA-LAM Products

VERSA-LAM. An Introduction to VERSA-LAM Products 44 VERSA-LAM An Introduction to VERSA-LAM Products VERSA-LAM is one of the strongest and stiffest engineered wood products approved in the UK. 241 302 356 406 VERSA-LAM products are excellent as floor

More information

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building

More information

A Study On Bracing Systems On High Rise Steel Structures Jagadish J. S [1], Tejas D. Doshi [2]

A Study On Bracing Systems On High Rise Steel Structures Jagadish J. S [1], Tejas D. Doshi [2] Abstract A Study On Bracing Systems On High Rise Steel Structures Jagadish J. S [1], Tejas D. Doshi [2] 1-Post Graduate Student, Department of Civil Engineering, KLE Dr. MSSCET, Belgaum, Karnataka, India,

More information

Rigid Connections. Between Wood posts and concrete

Rigid Connections. Between Wood posts and concrete Research + Technology Research + Technology Rigid Connections Between Wood posts and concrete By David R. Bohnhoff, PHD, PE Modeling Connections The primary goal of a structural engineer is to ensure that

More information

SCREWED CONNECTIONS FOR CORRUGATED STEEL DIAPHRAGM CEILINGS IN FARM BUILDINGS. D. I. Masse, J. E. Turnbull, and C. J. Williams

SCREWED CONNECTIONS FOR CORRUGATED STEEL DIAPHRAGM CEILINGS IN FARM BUILDINGS. D. I. Masse, J. E. Turnbull, and C. J. Williams SCREWED CONNECTIONS FOR CORRUGATED STEEL DIAPHRAGM CEILINGS IN FARM BUILDINGS D. I. Masse, J. E. Turnbull, and C. J. Williams Engineering and StatisticalResearchInstitute, Research Branch, Agriculture

More information

CCFSS Technical Bulletin

CCFSS Technical Bulletin CCFSS Technical Bulletin Vol. 12, No. 1 February 2003 FREQUENTLY ASKED QUESTIONS CONCERNING THE AISI BASE TEST METHOD AND THE USE OF THE AISI ANCHORAGE EQUATIONS Answers Provided by the AISI Task Committee

More information

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES Andi Asiz 1*, Lina Zhou 1, Ying Hei Chui 1 ABSTRACT: Connections are arguably the most important part of light-frame

More information

HOW TO BUILD A 12X8 SHED

HOW TO BUILD A 12X8 SHED HOW TO BUILD A 12X8 SHED With Illustrations, Drawings & Step By Step Details Note: This is a sample plan from RyanShedPlans. All other plans in our collection goes indepth with more details, more instructions,

More information

Connection and Tension Member Design

Connection and Tension Member Design Connection and Tension Member Design Notation: A = area (net = with holes, bearing = in contact, etc...) Ae = effective net area found from the product of the net area An by the shear lag factor U Ab =

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations STRUCTURAL CRITERIA FOR RESIDENTIAL FLUSH-MOUNTED SOLAR ARRAYS 1. ROOF CHECKS A. Visual Review/Contractor s Site Audit

More information

Introduction. to Wall Bracing

Introduction. to Wall Bracing Introduction to Wall Bracing 2 Wall Bracing is one of the most important structural elements of any house, but it can also be one of the most confusing. The 2006 International Residential Code (IRC) outlines

More information

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D. With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e H O W B U I L D S H E D. C O M Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,

More information

Egger Roofing Board Fast, Easy, Safe: With this board you can reach the top.

Egger Roofing Board Fast, Easy, Safe: With this board you can reach the top. Egger Roofing Board Fast, Easy, Safe: With this board you can reach the top. 1 2 Content Content 1 2 Roof Sheathing 4 Importance 4 EGGER Roofing Board 5 Benefits 5 Principles of the EGGER Roofing Board

More information

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames Andy van Houtte Product Engineer-LVL Nelson Pine Industries Nelson, NZ Andy Buchanan Professor of Civil Engineering Peter Moss Associate

More information

Z and C - sections ZED PURLIN SYSTEMS. Design tables according to Eurocodes. For secondary steel structures. Large range of. Z and C - sections

Z and C - sections ZED PURLIN SYSTEMS. Design tables according to Eurocodes. For secondary steel structures. Large range of. Z and C - sections ZED PURLIN SYSTEMS Large range of Z and C - sections System solution Purlins and side rails Eaves beams Floor beams Framing Easy design in software MetSPEC 12 Z and C - sections For secondary steel structures

More information

2.3 SPECIFIC DESIGN DHS PURLINS

2.3 SPECIFIC DESIGN DHS PURLINS 2.3 SPECIFIC DESIGN DHS PURLINS 2.3.1 INTRODUCTION Dimond Hi-Span (DHS) Purlin Systems have been designed to comply with AS/NZS 4600:1996, based on physical testing and analysis carried out by the University

More information

ASSESSMENT OF BASIC STEEL I-SECTION BEAM BRACING REQUIREMENTS BY TEST SIMULATION

ASSESSMENT OF BASIC STEEL I-SECTION BEAM BRACING REQUIREMENTS BY TEST SIMULATION ASSESSMENT OF BASIC STEEL I-SECTION BEAM BRACING REQUIREMENTS BY TEST SIMULATION A Thesis By Evan P. Prado In Partial Fulfillment Of the Requirements for the Degree Master of Science in Civil Engineering

More information

Product Information & Installation Instructions

Product Information & Installation Instructions Product Information & Installation Instructions TUFF-STRAND TM OSB Sheathing OSB Structural Panels from MARTCO Installation Instructions: Site-Built and Modular Construction Important Notice to Buyers

More information

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1 Academic resources Timber Connections Dowel-type fasteners Version 1 This unit covers the following topics: Deferent types of dowel-type fasteners Introduction There are four criteria designers should

More information

PV System Structural Criteria

PV System Structural Criteria PV System Structural Criteria Town of Atherton Building Department 91 Ashfield Road Atherton, California 94027 Phone: (650) 752-0560 STRUCTURAL CRITERIA FOR RESIDENTIAL ROOFTOP FLUSH-MOUNTED SOLAR ARRAYS

More information

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams Glulam Curved Members Glulam Design General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams There is an Additional Adjustment Factor, C v, the Volume Factor C v and C L (Lateral Stability

More information

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints TECHNICAL MANUAL TERADOWEL and ULTRADOWEL Reliable Dowel System for Floor Joints Version: PEIKKO GROUP 11/2018 TERADOWEL and ULTRADOWEL Reliable Dowel System for Floor Joints Dowels manufactured from high

More information

DUTCH GABLE FREESTANDING CARPORT

DUTCH GABLE FREESTANDING CARPORT DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If

More information

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners Lecture Slides Screws, Fasteners, and the Design of Nonpermanent Joints Reasons for Non-permanent Fasteners Field assembly Disassembly Maintenance Adjustment 1 Introduction There are two distinct uses

More information

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631 APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2016 lecture nineteen wood construction and design Wood Construction 1 Timber Construction all-wood framing systems

More information

IDEA Connections. User guide

IDEA Connections. User guide IDEA Connections user guide IDEA Connections User guide IDEA Connections user guide Content 1.1 Program requirements... 4 1.1 Installation guidelines... 4 2 User interface... 5 2.1 3D view in the main

More information

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings. Send Orders for Reprints to reprints@benthamscience.ae The Open Construction and Building Technology Journal, 2015, 9, 1-6 1 Open Access Investigation of Shear Stiffness of Spine Bracing Systems in Selective

More information

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3072 Reissued 09/2018 Revised 10/2018 This report is subject to renewal 09/2020.

More information

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES Vol. 10, Issue /014, 51-60 DOI: 10.478/cee-014-0011 LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES Jozef GOCÁL 1,* 1 Department of Structures and Bridges, Faculty of Civil

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations TOOLKIT DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations CRITERIA FOR RESIDENTIAL FLUSH-MOUNTED SOLAR ARRAYS STRUCTURAL 1. ROOF CHECKS A. Visual Review/Contractor s Site

More information

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,

More information

HECO-TOPIX -CombiConnect HECO-TOPIX -Therm HCS-Calculation software

HECO-TOPIX -CombiConnect HECO-TOPIX -Therm HCS-Calculation software HECO-TOPIX -CombiConnect HECO-TOPIX -Therm HCS-Calculation software THE WOOD SCREW FOR THE PROFESSIONAL The HECO-Calculation software (HCS) and HECO-TOPIX Woodscrews for easy estimation and safe assembling

More information

How to make a Wendy house Part One: The Floor and the Frame

How to make a Wendy house Part One: The Floor and the Frame How to make a Wendy house Part One: The Floor and the Frame The Wendy House. This wendy house is basically a playhouse with a few feminine touches added. A wendy house can give children hours of enjoyment.

More information

Review of AISI Design Guide for Cold-formed Steel Purlin Roof Framing Systems-component Stiffness Method

Review of AISI Design Guide for Cold-formed Steel Purlin Roof Framing Systems-component Stiffness Method Missouri University of Science and Technology Scholars' Mine International Specialty Conference on Cold- Formed Steel Structures (2010) - 20th International Specialty Conference on Cold-Formed Steel Structures

More information

GARDEN SHED BRIGHTOLN

GARDEN SHED BRIGHTOLN ASSEMBLY INSTRUCTIONS GARDEN SHED BRIGHTOLN Dimensions: 10x10 (1 1/8") IMPORTANT Before beginning the assembly of your garden shed, please read the instructions carefully and follow them closely. By doing

More information

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system Posi-Joist Installation Guide A guide for storage, handling and installation of the MiTek Posi-Joist floor system Posi-Joist Installation Details A B C D F E A Masonry Wall Connection Details Blockwork

More information

APPENDIX 1 : Post and Beam Model

APPENDIX 1 : Post and Beam Model Good Practice Guide to Hut Building Prepared by Reforesting Scotland s Campaign for a Thousand Huts (5th Draft) APPENDIX 1 : Post and Beam Model Peter Caunt & Bernard Planterose June 2017 www.thousandhuts.org

More information

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA INSTALLATION GUIDE VERSA-LAM BCI LIMIT STATES DESIGN CANADA The information in this document pertains use in the CANADA ONLY, Limit States Design. Refer the appropriate Specifier Guide US for use in the

More information

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load capacity of 2x

More information

lindab we simplify construction LindabStandingSeamRoofing Application guide

lindab we simplify construction LindabStandingSeamRoofing Application guide lindab we simplify construction LindabStandingSeamRoofing Application guide This handbook deals with long strip roofing with Lindab PLX on a boarded roof covering. The instructions in this handbook are

More information

Load Tables, Technical Data and Installation Instructions

Load Tables, Technical Data and Installation Instructions W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting

More information

European Technical Assessment. ETA-15/0667 of Member of. General part

European Technical Assessment. ETA-15/0667 of Member of. General part INSTITU Schenkenstrasse 4 T +43 1 533 65 50 1010 Vienna Ι Austria F +43 1 533 64 23 www.oib.or.at Ι mail@oib.or.at Designated according to Article 29 of Regulation (EU) No 305/2011 Member of www.eota.eu

More information

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1. LP SolidStart LSL LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.35E LSL Please verify availability with the LP SolidStart Engineered Wood Products

More information

AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS

AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS MacArthur L. Stewart 1 1 Assistant Professor, Mechanical Engineering Technology Department, Eastern Michigan University, MI, USA Abstract Abstract Researchers

More information