1 Acrowall-CP Cement-Plaster Stucco SYSTEM DESCRIPTION Typical Details 1. ACROWALL-CP SYSTEM APPLICATION 2. ACROWALL-CP SYSTEM APPLICATION WITH EPS BOARD 3. ACROWALL-CP SYSTEM ISOMETRIC VIEW 4. SURFACE CONTROL JOINT (PLAN VIEW) 5. CLAD WINDOW JAMB (PLAN VIEW) 6. CLAD WINDOW HEAD 7. CLAD WINDOW SILL 8. PRIMED WINDOW HEAD 9. PRIMED WINDOW JAMB 10. PRIMED WINDOW SILL 11. HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION 12. TERMINATION AT SOFFIT/GABLE END 13. DOWNSPOUT APPLICATION (PLAN VIEW) 14. PIPE PENETRATION 15. LIGHT FIXTURE 16. DRYER VENT 17. TERMINATION AT FOUNDATION 18. TERMINATION AT TOP OF DECK 19. TERMINATION AT BOTTOM OF DECK 20. METAL COPING 21. EPS SHAPE APPLICATION 22. CORNER BEAD (PLAN VIEW) 23. KICK-OUT FLASHING
2 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 ACROPRIMER TM (OPTIONAL) 1. TYPICAL ACROWALL-CP SYSTEM APPLICATION 25 MM (1 ) TONGUE & GROOVE EPS PERMALATH 1000 ACROCRETE STUCCOBASE TM ACROPRIMER (OPTIONAL) 2. TYPICAL ACROWALL-CP SYSTEM APPLICATION ATION WITH EPS BOARD
3 NOTE: Framing, acceptable sheathing PERMALATH 1000 (ACROPRIMER TM OPTIONAL) OR WEEP SCREED 3. TYPICAL ACROWALL-CP SYSTEM ISOMETRIC VIEW OR AS REQUIRED BY CODE PERMALATH TM 1000 SURFACE MOUNTED CONTROL JOINT ACROCRETE STUCCOBASE TM 4. TYPICAL SURFACE CONTROL JOINT (PLAN VIEW)
4 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER CLAD WINDOW 5. TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW) A WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM FLASHING SEALANT CLAD WINDOW 6. TYPICAL CLAD WINDOW HEAD DETAIL
5 NOTE: Framing, acceptable sheathing CLAD WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH TYPICAL CLAD WINDOW SILL DETAIL OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) SEALANT PRIMED WINDOW 8. TYPICAL PRIMED WINDOW HEAD DETAIL
6 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE PRIMED WINDOW 9. TYPICAL PRIMED WINDOW JAMB DETAIL PRIMED WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 ACROCRETE STUCCOBASE TM 10. TYPICAL PRIMED WINDOW SILL DETAIL
7 NOTE: Framing, acceptable sheathing MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 DEEP V CONTROL JOINT OR BACK TO BACK WITH BACKER ROD AND SEALANT MIN. 13 MM (1/2 ) (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 11. TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION BLOCKING SOFFIT TRIM FRIEZE BOARD OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM 12. TYPICAL TERMINATION AT SOFFIT/GABLE END
8 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing SET IN SEALANT SEALANT SLEEVE DOWNSPOUT STRAP DOWNSPOUT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 13. TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW) MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 SEALANT AT PERIMETER OF PENETRATION SEALANT ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 14. TYPICAL PIPE PENETRATION
9 NOTE: Framing, acceptable sheathing SET FLANGE IN SEALANT SMALL LIGHT FIXTURE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 WIRE OPENING (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 15. TYPICAL LIGHT FIXTURE SET IN SEALANT SET FLANGE IN SEALANT DRYER VENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 16. TYPICAL DRYER VENT
10 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MINIMUM GRADE D BUILDING P WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000APER WEEP SCREED NOTE: TERMINATE STUCCO SYSTEM 203 MM (8 ) MIN. ABOVE GRADE. 17. TYPICAL TERMINATION AT FOUNDATION TYPICAL WOOD OR AS REQUIRED BY CODE WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM DECK FLASHING (SET IN SEALANT) JOIST SEALANT 18. TYPICAL TERMINATION AT TOP OF DECK
11 NOTE: Framing, acceptable sheathing JOIST FLASHING OR AS REQUIRED BY CODE PERMALATH TYPICAL TERMINATION AT BOTTOM OF DECK METAL COPING SEALANT ACCEPTABLE SHEATHING MIN. 50 MM (2 ) PERMALATH 1000 ACROCRETE STUCCOBASE TM 20. TYPICAL METAL COPING DETAIL
12 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MIN. 6:12 SLOPE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) ACROCRETE BASE COAT EPS AESTHETIC BAND ACROCRETE LAMINA: ACROCRETE BASE COAT ACROCRETE REINFORCING MESH NOTE: OVERLAP ACROMESH 4 A MIN. 76 MM (3 ) ONTO ACROCRETE BASE COAT. 21. TYPICAL EPS SHAPE APPLICATION CORNER BEAD OR CORNER AID REINFORCEMENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000 MIN. 50 MM (2 ) MAX. 305 MM (12 ) ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 22. TYPICAL CORNER BEAD DETAIL (PLAN VIEW)
13 NOTE: Framing, acceptable sheathing STEP FLASHING PERMALATH 1000 AND ACROCRETE FINISH BACKER ROD AND SEALANT MIN. 50 MM (2 ) MIN. 100 MM (4 ) NOTE: KICK-OUT FLASHING MUST BE ANGLED 100 MIN. TO ALLOW FOR PROPER DRAINAGE. SOLDERED OR SEALED WITH APPROPRIATE SEALANT. TERMINATE ACROWALL-CP SYSTEM 50 MM (2 ) MIN. ABOVE ROOF. BUILDING PAPER ROOF SHINGLES DRIP EDGE KICK-OUT FLASHING 23. TYPICAL KICK-OUT FLASHING DETAIL
14 NOTES
15 NOTES
16 RESIDENTIAL POLICY On one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction without expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.] Consult BASF Wall Systems Technical Services Department for specific recommendations concerning all other applications. Consult the Acrocrete web-site, for additional information about products and systems and for updated literature. DISCLAIMER This information and all further technical advice are based on BASF s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON- SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL P: F: BASF Printed in U.S.A. 11/06
Pebbletex Adhered Mat Design. Typical Details
Pebbletex Adhered Mat Design Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK) Pebbletex Adhered Mat Design TABLE OF CONTENTS 1. Pebbletex Adhered Mat Design Application (Plan VIew) 2. Pebbletex Adhered
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationQuick Reference Guide For MoistureFree Certified Inspectors and Contractors
Quick Reference Guide For MoistureFree Certified Inspectors and Contractors Topic Page No. Critical Elements Of The Kickout 2 Bad Kickout Examples 3 Raintek Kickout By Demand Products 4 Inspecting and
More informationCFDTT-01. Control Joint Study (General)
Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area
More information3M Air and Vapour Barrier 3015 Technical guide
3M Air and Vapour Barrier 3015 Technical guide Product overview Typical physical properties For installation ease and flexibility, 3M Air and Vapour Barrier 3015 High performance 3M acrylic adhesive grabs
More informationNEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationTYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**
TYPAR WEATHER PROTECTION SYSTEM INSTALLATION GUIDE TABLE OF CONTENTS Table of Contents...01 Special Installation Considerations...01 Code Requirements...02 Approvals and Reports...02 Recommended Materials...02
More informationAll Window Installation Instruction
1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM
More informationInstallation Instructions for Panel Siding and Soffit
Installation Instructions for Panel Siding and Soffit 7/16 in. Panels Include: Sturdy Panel, Square Edge, 3/4 in. Channel and Reverse Board and Batten (RB&B) 1/2 in. Panels Include: Adobe Shiplap and 808
More informationForceField Air & Water Barrier System. installation instructions
ForceField Air & Water Barrier System installation instructions Protection and Performance inside and out The ForceField air and water barrier system consists of engineered wood sheathing panels laminated
More informationC.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationEagle clad double-hung window installation instructions
Eagle clad double-hung window installation instructions These instructions are for typical installation in new typical wood frame wall construction. These instructions and methods are not intended for
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationInstallation Guide for E-Series/Eagle Clad Mechanically Fastened Windows
Guide for E-Series/Eagle Clad Mechanically Fastened Windows Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place. Instructions
More informationInstallation Instructions for Standard Lap and Self-Aligning Lap Siding
Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.
More informationINSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows with nailing fin or primed wood windows with exterior trim. While the
More informationBuilding Wrap and Flashing
Insulati o n Fifth Revision January 2019 Building Wrap and Flashing INSTALLATION GUIDE FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS 1. General Information 2. Usage & Limitations MAX, HPW, VW, RainDrop
More informationINSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN
MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE
More information26- H i n g e d P a t i o D o o r s - I n s w i n g
Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested
More informationFlashing Materials. Rough Opening Preparation
Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or
More informationPRIMED STRAND REVERSIBLE SHAKE
PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems
More informationNEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS
NEW CONSTUCTION, REPLACEMENT & FLUSH FIN WINDOWS NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.
More informationInstallation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window
Installation Guidelines Next Dimension Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Windsor Windows & Doors Windsor Windows & Doors 900 S. 19 th St. 2210 Stafford St. Extn
More informationBuilding Wrap and Flashing
Insulati o n First Revision November 2017 Building Wrap and Flashing INSTALLATION GUIDE FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS 1. General Information 2. Usage & Limitations 5. Handling & Storage
More informationInstallation Instructions for TruWood Reversible Trim
Installation Instructions for TruWood Reversible Trim Important: Read and understand all pages of the installation instructions before starting the trim application. For TruWood care and maintenance information,
More informationRead guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed
More informationInstallation Instructions for Old Mill Shingle and Designer Shake Lap Siding
Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Includes: Cove, Craftsmen Staggered, Diamond, Fish Scale, Octagon, Round and Old Mill Shingle Lap Important: Read and understand
More informationInstallation Manual for Thermo Panel
Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on
More informationInstallation Instructions
Installation Instructions SLICKER MAX RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Top of Wall Detail 5 Bottom of Wall Detail 6 Wall Corner Detail
More informationInstallation Guide - Evolution Series Wood Siding
Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration
More information900 SERIES WALL PANELS
CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900
More informationLP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information
Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture A B A - Open / Closed (Page 5) B - Vented (Page 6) ON SITE STORAGE Store off the ground well supported, on a flat well-drained
More informationIntegrity Polygon and Round Top Installation and Finishing Instructions
Integrity Polygon and Round Top Installation and Finishing Instructions 08/20/2004 70852 BEFORE YOU BEGIN IMPORTANT: Read these instructions thoroughly before beginning to install your Integrity Polygon
More informationASPHALT T E C H N O L O G I E S
ASPHALT T E C H N O L O G I E S Evaluation of Active Ventilation Products Inc. Aura-D (AV-24) Ventilator in Accordance With FLORIDA BUILDING CODE PROTOCOL TAS 100(A)-95 TEST PROCEDURE FOR WIND AND WIND
More informationTools required by installer: Materials required by installer:
Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely
More informationDW VERTICAL INSTALLATION
AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.
More informationSERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION
IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS
More informationInstallation Instructions
Installation Instructions SLICKER CLASSIC RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Insulation Board Installation 5 EIFS Installation 6 Top of
More information400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationInstallation Recommendations for Finless Frame Doors
Installation Recommendations for Finless Frame Doors These installation recommendations are made available by MI Windows and Doors, LLC (MI) to assist with the integration of finless or flange sliding
More informationULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS
ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.
More informationAdorn Mortarless Stone Veneer Installation Natural Concrete Products
Adorn Mortarless Stone Veneer Installation Adorn Mortarless Stone Veneer can be used on new or existing construction. Adorn is nailed or screwed onto the wall; therefore no brick ledge is required. Adorn
More informationINSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS
www.capecodsiding.com INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS IMPORTANT READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING YOUR WOOD SIDING. FAILURE TO STRICTLY FOLLOW THESE INSTALLATION,
More informationUC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER
CAMPUS STANDARDS APPENDIX I UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 WINDOW INSTALLATION SEQUENCING GUIDE Issued By: Pyatok Architects and Allana Buick &
More informationThe Beauty Of Wood. Made Better. Product Specifications LPZB0590
The Beauty Of Wood. Made Better. Product Specifications LPZB0590 LP SmartSide Trim Specifications Reversible Two Premium Looks The natural look of cedar on one side and smooth on the other Interior or
More informationWALL TO FABRICATED FLOOR
WALL TO FABRICATED FLOOR PERIMETER WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN PARTITION WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN
More informationINSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.
for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows
More informationHowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org
HowtoPlans.org 24'x8' Walk In Chicken Coop Plan Designed for up to 50 chickens Disclaimer The information provided here will show you how to build a chicken coop. However, we at howtoplans.org do not claim
More informationBefore installation, check your local and state requirements for this type of install.
1 Remove Packaging & Inspect Your Patio Door Remove shipping materials such as corner covers or pads. 2 Inspect Rough Opening Verify that the width and height of the patio door are each 1/2" to 3/4" smaller
More informationInstallation Guide. for E-Series/Eagle Clad Hinged Inswing French Door
Installation Guide for E-Series/Eagle Clad Hinged Inswing French Door Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place.
More informationWEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS
CORE WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS Proper Window & Door Flashing Although all possible measures have been taken to insure the accuracy of the material presented,
More informationAIA Specification. Section Slate Shingles PART 1 GENERAL
AIA Specification Section 07315 Slate Shingles PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More informationHowtoPlans..org. 12'x20' Garden Shed Plan
HowtoPlans.org 12'x20' Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard or
More informationINSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS
for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay
More information8 x 10 Timber-frame Garden Shed
8 x 10 Timber-frame Garden Shed Includes: Step-By-Step Instructions, Complete Details & Materials Lists Timber-framing is a traditional building method that uses a simple framework of heavy timber posts
More informationUC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD
CAMPUS STANDARDS APPENDIX H UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD December 5, 2014 Window Installation Sequencing Guide Pyatok Architects and Allana Buick & Bers Inc. 12/5/2014
More informationDETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY
2x DIMENSIONAL LUMBER SISTER/SCAB REINFORCEMENT MEMBER 060523 3/8" A304 BOLT @ 8" O.C., STAGGERED EXISTING FRAMING MEMBER SECTION PROVIDE MIN EDGE DISTANCES AS SHOWN, TYP. ELEVATION REFER TO IFICATION
More informationL:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET
KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH
More information3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25
3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 1 Directions For Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to building code and local amendments.
More informationThe City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.
Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 PART 1 GENERAL 1.1 SCOPE OF WORK.1 Total roof area approximately 1,312 m 2. The Work includes, but is not limited to:.1 Removal and disposal
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation
More informationINSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)
for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation
More informationHowtoPlans..org. DuraMax 8'x12 Garden Shed Plan
HowtoPlans.org DuraMax 8'x12 Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard
More informationINSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS
for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows
More informationHow To Install Windows: Nail-Fin Application
How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:
More informationSections & Details VOCABULARY
1 Sections & Details VOCABULARY 1 ROOF FRAMING DETAIL RIDGE BOARD SHEATHING SHINGLES WEB FASCIA RAFTER (chord) SOFFIT SHEATHING STUD INSULATION DOUBLE TOP PLATE CEILING JOIST 2 FOUNDATION DETAIL STUD SHEATHING
More informationTECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING
TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TABLE OF CONTENTS This installation guide provides detailed step-by-step instructions for do-it-yourself projects. We invite you to read it carefully and
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationAppendix A. Additional Information ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF)
Appendix A Additional ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF) Considering the proprietary nature of Insulated Concrete Forms (ICF) and the number of ICF manufacturers currently
More informationSERIES 300 SINGLE HUNG WINDOW INSTALLATION
IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS
More informationSHEET METAL FLASHING AND TRIM Christ on the Mountain
SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Compatibly with the bumping of flashings and trim as identified in the Membrane Roofing Section 075000.
More informationDefinitions and Design Considerations... W-CR-2
General Information SECTION DIRECTORY Definitions and Design Considerations... W-CR-2 Combination Assembly Recommendations and Limitations Typical Sealant... W-CR-4 Single-Unit Opening... W-CR-4 Two-Way
More informationTABLE OF CONTENTS A. PBR
TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR
More informationInstallation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.
Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.
More informationINSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl bay, bow and garden windows which incorporate an integral nailing fin. While the use of
More informationINSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS
2012 Pella Corporation INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS Part Number: 802L0105 Installation Instructions for Typical Wood Frame Construction. These instructions were developed tested
More informationSlate Shingle Specifications
Slate Shingle Specifications California Slate is a proud member of the Slate Roofing Contractors Association of North America, Inc. (SRCA) which publishes Section 07310 Slate Shingles setting forth architectural
More informationINSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2012 Pella Corporation Part Number: 80WH0101 INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Installation Instructions for Typical Wood Frame Construction.
More information12x12 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationINSTALLATION INSTRUCTIONS for Wood Patio Doors with Exterior Trim or Nailing Fin (JII026)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood patio doors with exterior trim or nailing fin. Read these instructions thoroughly before
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationHydroGap Drainable Housewrap: Installation Instructions
METHOD I: MODIFIED O or CUT-BACK Method STEP 1 Unroll HydroGap Drainable Housewrap with blue spacers facing to the exterior and fasten to sheathing with nails, staples or cap fasteners. Fasteners should
More information8x8 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationINSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.
FASTER. TIGHTER. ENERGY EFFICIENT. FROM THE CREATORS OF ZIP System Roof & Wall Sheathing INSTALLATION MANUAL Sales Office: 10925 David Taylor Dr., Suite 300 Phone: 800-933-9220 zipsystem.com Charlotte,
More information1 Exam Prep Prov Module: Exterior Finishing Questions and Answers
1 Exam Prep Prov Module: 27204-13 Exterior Finishing Questions and Answers 1. From a safety standpoint, a carpenter's most important piece of clothing is probably. A. A long-sleeved shirt B. Work shoes
More informationINSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl bay, bow and garden windows which incorporate an integral nailing fin. Read these instructions
More informationMaterials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel
This 8 12-ft. shed features a simple gable roof, double doors, and side and rear windows for natural lighting. With full-height walls and doors, there's ample room for storing large items or creating a
More informationInstallation Instructions
Installation Instructions HYDROGAP DRAINABLE HOUSEWRAP AND ACCESSORIES Page Basic Installation and Window Flashing: Pre-Installation Considerations 2 List of Approved Compatible Products 3 METHOD I: Modified
More information(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS
Thank you for selecting C l i m a t e G u a r d products. Attached are our recommended installation instructions for Vinyl windows with an integral (2400-02) will not affect application of the ClimateGuard
More informationFibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm
More informationTechnical Note No. 026
Technical Note No. 026 Strand Substrate Installed Vertically for Board & or Board-on-Board Applications This Technical Note is an addendum to the Strand Substrate Application Instructions and Trim and
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationVinyl Windows Manufactured by VPI Quality Windows
Vinyl Windows Manufactured by VPI Quality Windows Part Number: 531&591 Installation 531 & 591 SERIES SLIDING AND HUNG WINDOW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction.
More informationSPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS
FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE 2 ND EDITION FLASHING SYSTEM FUNCTIONALLY UNIQUE. ENGINEERED PRODUCT SYSTEMS / FLASHING Fry Reglet comprehensive selection of moisture prevention
More informationPANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS
PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS This product can be used for interior and exterior installations. Much of this guide refers to exterior installation, however, many of the construction
More information