Acrowall-CP Cement-Plaster Stucco

Size: px
Start display at page:

Download "Acrowall-CP Cement-Plaster Stucco"

Transcription

1 Acrowall-CP Cement-Plaster Stucco SYSTEM DESCRIPTION Typical Details 1. ACROWALL-CP SYSTEM APPLICATION 2. ACROWALL-CP SYSTEM APPLICATION WITH EPS BOARD 3. ACROWALL-CP SYSTEM ISOMETRIC VIEW 4. SURFACE CONTROL JOINT (PLAN VIEW) 5. CLAD WINDOW JAMB (PLAN VIEW) 6. CLAD WINDOW HEAD 7. CLAD WINDOW SILL 8. PRIMED WINDOW HEAD 9. PRIMED WINDOW JAMB 10. PRIMED WINDOW SILL 11. HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION 12. TERMINATION AT SOFFIT/GABLE END 13. DOWNSPOUT APPLICATION (PLAN VIEW) 14. PIPE PENETRATION 15. LIGHT FIXTURE 16. DRYER VENT 17. TERMINATION AT FOUNDATION 18. TERMINATION AT TOP OF DECK 19. TERMINATION AT BOTTOM OF DECK 20. METAL COPING 21. EPS SHAPE APPLICATION 22. CORNER BEAD (PLAN VIEW) 23. KICK-OUT FLASHING

2 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 ACROPRIMER TM (OPTIONAL) 1. TYPICAL ACROWALL-CP SYSTEM APPLICATION 25 MM (1 ) TONGUE & GROOVE EPS PERMALATH 1000 ACROCRETE STUCCOBASE TM ACROPRIMER (OPTIONAL) 2. TYPICAL ACROWALL-CP SYSTEM APPLICATION ATION WITH EPS BOARD

3 NOTE: Framing, acceptable sheathing PERMALATH 1000 (ACROPRIMER TM OPTIONAL) OR WEEP SCREED 3. TYPICAL ACROWALL-CP SYSTEM ISOMETRIC VIEW OR AS REQUIRED BY CODE PERMALATH TM 1000 SURFACE MOUNTED CONTROL JOINT ACROCRETE STUCCOBASE TM 4. TYPICAL SURFACE CONTROL JOINT (PLAN VIEW)

4 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER CLAD WINDOW 5. TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW) A WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM FLASHING SEALANT CLAD WINDOW 6. TYPICAL CLAD WINDOW HEAD DETAIL

5 NOTE: Framing, acceptable sheathing CLAD WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH TYPICAL CLAD WINDOW SILL DETAIL OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) SEALANT PRIMED WINDOW 8. TYPICAL PRIMED WINDOW HEAD DETAIL

6 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE PRIMED WINDOW 9. TYPICAL PRIMED WINDOW JAMB DETAIL PRIMED WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 ACROCRETE STUCCOBASE TM 10. TYPICAL PRIMED WINDOW SILL DETAIL

7 NOTE: Framing, acceptable sheathing MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 DEEP V CONTROL JOINT OR BACK TO BACK WITH BACKER ROD AND SEALANT MIN. 13 MM (1/2 ) (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 11. TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION BLOCKING SOFFIT TRIM FRIEZE BOARD OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM 12. TYPICAL TERMINATION AT SOFFIT/GABLE END

8 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing SET IN SEALANT SEALANT SLEEVE DOWNSPOUT STRAP DOWNSPOUT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 13. TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW) MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 SEALANT AT PERIMETER OF PENETRATION SEALANT ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 14. TYPICAL PIPE PENETRATION

9 NOTE: Framing, acceptable sheathing SET FLANGE IN SEALANT SMALL LIGHT FIXTURE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 WIRE OPENING (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 15. TYPICAL LIGHT FIXTURE SET IN SEALANT SET FLANGE IN SEALANT DRYER VENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 16. TYPICAL DRYER VENT

10 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MINIMUM GRADE D BUILDING P WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000APER WEEP SCREED NOTE: TERMINATE STUCCO SYSTEM 203 MM (8 ) MIN. ABOVE GRADE. 17. TYPICAL TERMINATION AT FOUNDATION TYPICAL WOOD OR AS REQUIRED BY CODE WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM DECK FLASHING (SET IN SEALANT) JOIST SEALANT 18. TYPICAL TERMINATION AT TOP OF DECK

11 NOTE: Framing, acceptable sheathing JOIST FLASHING OR AS REQUIRED BY CODE PERMALATH TYPICAL TERMINATION AT BOTTOM OF DECK METAL COPING SEALANT ACCEPTABLE SHEATHING MIN. 50 MM (2 ) PERMALATH 1000 ACROCRETE STUCCOBASE TM 20. TYPICAL METAL COPING DETAIL

12 ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MIN. 6:12 SLOPE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) ACROCRETE BASE COAT EPS AESTHETIC BAND ACROCRETE LAMINA: ACROCRETE BASE COAT ACROCRETE REINFORCING MESH NOTE: OVERLAP ACROMESH 4 A MIN. 76 MM (3 ) ONTO ACROCRETE BASE COAT. 21. TYPICAL EPS SHAPE APPLICATION CORNER BEAD OR CORNER AID REINFORCEMENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000 MIN. 50 MM (2 ) MAX. 305 MM (12 ) ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 22. TYPICAL CORNER BEAD DETAIL (PLAN VIEW)

13 NOTE: Framing, acceptable sheathing STEP FLASHING PERMALATH 1000 AND ACROCRETE FINISH BACKER ROD AND SEALANT MIN. 50 MM (2 ) MIN. 100 MM (4 ) NOTE: KICK-OUT FLASHING MUST BE ANGLED 100 MIN. TO ALLOW FOR PROPER DRAINAGE. SOLDERED OR SEALED WITH APPROPRIATE SEALANT. TERMINATE ACROWALL-CP SYSTEM 50 MM (2 ) MIN. ABOVE ROOF. BUILDING PAPER ROOF SHINGLES DRIP EDGE KICK-OUT FLASHING 23. TYPICAL KICK-OUT FLASHING DETAIL

14 NOTES

15 NOTES

16 RESIDENTIAL POLICY On one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction without expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.] Consult BASF Wall Systems Technical Services Department for specific recommendations concerning all other applications. Consult the Acrocrete web-site, for additional information about products and systems and for updated literature. DISCLAIMER This information and all further technical advice are based on BASF s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON- SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL P: F: BASF Printed in U.S.A. 11/06

Pebbletex Adhered Mat Design. Typical Details

Pebbletex Adhered Mat Design. Typical Details Pebbletex Adhered Mat Design Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK) Pebbletex Adhered Mat Design TABLE OF CONTENTS 1. Pebbletex Adhered Mat Design Application (Plan VIew) 2. Pebbletex Adhered

More information

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy

More information

Quick Reference Guide For MoistureFree Certified Inspectors and Contractors

Quick Reference Guide For MoistureFree Certified Inspectors and Contractors Quick Reference Guide For MoistureFree Certified Inspectors and Contractors Topic Page No. Critical Elements Of The Kickout 2 Bad Kickout Examples 3 Raintek Kickout By Demand Products 4 Inspecting and

More information

CFDTT-01. Control Joint Study (General)

CFDTT-01. Control Joint Study (General) Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area

More information

3M Air and Vapour Barrier 3015 Technical guide

3M Air and Vapour Barrier 3015 Technical guide 3M Air and Vapour Barrier 3015 Technical guide Product overview Typical physical properties For installation ease and flexibility, 3M Air and Vapour Barrier 3015 High performance 3M acrylic adhesive grabs

More information

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes

More information

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding** TYPAR WEATHER PROTECTION SYSTEM INSTALLATION GUIDE TABLE OF CONTENTS Table of Contents...01 Special Installation Considerations...01 Code Requirements...02 Approvals and Reports...02 Recommended Materials...02

More information

All Window Installation Instruction

All Window Installation Instruction 1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM

More information

Installation Instructions for Panel Siding and Soffit

Installation Instructions for Panel Siding and Soffit Installation Instructions for Panel Siding and Soffit 7/16 in. Panels Include: Sturdy Panel, Square Edge, 3/4 in. Channel and Reverse Board and Batten (RB&B) 1/2 in. Panels Include: Adobe Shiplap and 808

More information

ForceField Air & Water Barrier System. installation instructions

ForceField Air & Water Barrier System. installation instructions ForceField Air & Water Barrier System installation instructions Protection and Performance inside and out The ForceField air and water barrier system consists of engineered wood sheathing panels laminated

More information

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

Eagle clad double-hung window installation instructions

Eagle clad double-hung window installation instructions Eagle clad double-hung window installation instructions These instructions are for typical installation in new typical wood frame wall construction. These instructions and methods are not intended for

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows Guide for E-Series/Eagle Clad Mechanically Fastened Windows Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place. Instructions

More information

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Instructions for Standard Lap and Self-Aligning Lap Siding Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows with nailing fin or primed wood windows with exterior trim. While the

More information

Building Wrap and Flashing

Building Wrap and Flashing Insulati o n Fifth Revision January 2019 Building Wrap and Flashing INSTALLATION GUIDE FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS 1. General Information 2. Usage & Limitations MAX, HPW, VW, RainDrop

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information

26- H i n g e d P a t i o D o o r s - I n s w i n g

26- H i n g e d P a t i o D o o r s - I n s w i n g Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested

More information

Flashing Materials. Rough Opening Preparation

Flashing Materials. Rough Opening Preparation Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or

More information

PRIMED STRAND REVERSIBLE SHAKE

PRIMED STRAND REVERSIBLE SHAKE PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems

More information

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS NEW CONSTUCTION, REPLACEMENT & FLUSH FIN WINDOWS NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

More information

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Installation Guidelines Next Dimension Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Windsor Windows & Doors Windsor Windows & Doors 900 S. 19 th St. 2210 Stafford St. Extn

More information

Building Wrap and Flashing

Building Wrap and Flashing Insulati o n First Revision November 2017 Building Wrap and Flashing INSTALLATION GUIDE FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS 1. General Information 2. Usage & Limitations 5. Handling & Storage

More information

Installation Instructions for TruWood Reversible Trim

Installation Instructions for TruWood Reversible Trim Installation Instructions for TruWood Reversible Trim Important: Read and understand all pages of the installation instructions before starting the trim application. For TruWood care and maintenance information,

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Includes: Cove, Craftsmen Staggered, Diamond, Fish Scale, Octagon, Round and Old Mill Shingle Lap Important: Read and understand

More information

Installation Manual for Thermo Panel

Installation Manual for Thermo Panel Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on

More information

Installation Instructions

Installation Instructions Installation Instructions SLICKER MAX RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Top of Wall Detail 5 Bottom of Wall Detail 6 Wall Corner Detail

More information

Installation Guide - Evolution Series Wood Siding

Installation Guide - Evolution Series Wood Siding Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture A B A - Open / Closed (Page 5) B - Vented (Page 6) ON SITE STORAGE Store off the ground well supported, on a flat well-drained

More information

Integrity Polygon and Round Top Installation and Finishing Instructions

Integrity Polygon and Round Top Installation and Finishing Instructions Integrity Polygon and Round Top Installation and Finishing Instructions 08/20/2004 70852 BEFORE YOU BEGIN IMPORTANT: Read these instructions thoroughly before beginning to install your Integrity Polygon

More information

ASPHALT T E C H N O L O G I E S

ASPHALT T E C H N O L O G I E S ASPHALT T E C H N O L O G I E S Evaluation of Active Ventilation Products Inc. Aura-D (AV-24) Ventilator in Accordance With FLORIDA BUILDING CODE PROTOCOL TAS 100(A)-95 TEST PROCEDURE FOR WIND AND WIND

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely

More information

DW VERTICAL INSTALLATION

DW VERTICAL INSTALLATION AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V

More information

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3 Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.

More information

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Installation Instructions

Installation Instructions Installation Instructions SLICKER CLASSIC RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Insulation Board Installation 5 EIFS Installation 6 Top of

More information

400 SERIES VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V

More information

Installation Recommendations for Finless Frame Doors

Installation Recommendations for Finless Frame Doors Installation Recommendations for Finless Frame Doors These installation recommendations are made available by MI Windows and Doors, LLC (MI) to assist with the integration of finless or flange sliding

More information

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.

More information

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

Adorn Mortarless Stone Veneer Installation Natural Concrete Products Adorn Mortarless Stone Veneer Installation Adorn Mortarless Stone Veneer can be used on new or existing construction. Adorn is nailed or screwed onto the wall; therefore no brick ledge is required. Adorn

More information

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS www.capecodsiding.com INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS IMPORTANT READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING YOUR WOOD SIDING. FAILURE TO STRICTLY FOLLOW THESE INSTALLATION,

More information

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER CAMPUS STANDARDS APPENDIX I UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 WINDOW INSTALLATION SEQUENCING GUIDE Issued By: Pyatok Architects and Allana Buick &

More information

The Beauty Of Wood. Made Better. Product Specifications LPZB0590

The Beauty Of Wood. Made Better. Product Specifications LPZB0590 The Beauty Of Wood. Made Better. Product Specifications LPZB0590 LP SmartSide Trim Specifications Reversible Two Premium Looks The natural look of cedar on one side and smooth on the other Interior or

More information

WALL TO FABRICATED FLOOR

WALL TO FABRICATED FLOOR WALL TO FABRICATED FLOOR PERIMETER WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN PARTITION WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary. for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows

More information

HowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org

HowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org HowtoPlans.org 24'x8' Walk In Chicken Coop Plan Designed for up to 50 chickens Disclaimer The information provided here will show you how to build a chicken coop. However, we at howtoplans.org do not claim

More information

Before installation, check your local and state requirements for this type of install.

Before installation, check your local and state requirements for this type of install. 1 Remove Packaging & Inspect Your Patio Door Remove shipping materials such as corner covers or pads. 2 Inspect Rough Opening Verify that the width and height of the patio door are each 1/2" to 3/4" smaller

More information

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door Installation Guide for E-Series/Eagle Clad Hinged Inswing French Door Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place.

More information

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS CORE WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS Proper Window & Door Flashing Although all possible measures have been taken to insure the accuracy of the material presented,

More information

AIA Specification. Section Slate Shingles PART 1 GENERAL

AIA Specification. Section Slate Shingles PART 1 GENERAL AIA Specification Section 07315 Slate Shingles PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,

More information

HowtoPlans..org. 12'x20' Garden Shed Plan

HowtoPlans..org. 12'x20' Garden Shed Plan HowtoPlans.org 12'x20' Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard or

More information

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay

More information

8 x 10 Timber-frame Garden Shed

8 x 10 Timber-frame Garden Shed 8 x 10 Timber-frame Garden Shed Includes: Step-By-Step Instructions, Complete Details & Materials Lists Timber-framing is a traditional building method that uses a simple framework of heavy timber posts

More information

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD CAMPUS STANDARDS APPENDIX H UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD December 5, 2014 Window Installation Sequencing Guide Pyatok Architects and Allana Buick & Bers Inc. 12/5/2014

More information

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY 2x DIMENSIONAL LUMBER SISTER/SCAB REINFORCEMENT MEMBER 060523 3/8" A304 BOLT @ 8" O.C., STAGGERED EXISTING FRAMING MEMBER SECTION PROVIDE MIN EDGE DISTANCES AS SHOWN, TYP. ELEVATION REFER TO IFICATION

More information

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH

More information

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 1 Directions For Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to building code and local amendments.

More information

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No. Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 PART 1 GENERAL 1.1 SCOPE OF WORK.1 Total roof area approximately 1,312 m 2. The Work includes, but is not limited to:.1 Removal and disposal

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan HowtoPlans.org DuraMax 8'x12 Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows

More information

How To Install Windows: Nail-Fin Application

How To Install Windows: Nail-Fin Application How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:

More information

Sections & Details VOCABULARY

Sections & Details VOCABULARY 1 Sections & Details VOCABULARY 1 ROOF FRAMING DETAIL RIDGE BOARD SHEATHING SHINGLES WEB FASCIA RAFTER (chord) SOFFIT SHEATHING STUD INSULATION DOUBLE TOP PLATE CEILING JOIST 2 FOUNDATION DETAIL STUD SHEATHING

More information

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TABLE OF CONTENTS This installation guide provides detailed step-by-step instructions for do-it-yourself projects. We invite you to read it carefully and

More information

Ekoroof LiteTile Dimensions

Ekoroof LiteTile Dimensions Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)

More information

Appendix A. Additional Information ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF)

Appendix A. Additional Information ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF) Appendix A Additional ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF) Considering the proprietary nature of Insulated Concrete Forms (ICF) and the number of ICF manufacturers currently

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

SHEET METAL FLASHING AND TRIM Christ on the Mountain

SHEET METAL FLASHING AND TRIM Christ on the Mountain SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Compatibly with the bumping of flashings and trim as identified in the Membrane Roofing Section 075000.

More information

Definitions and Design Considerations... W-CR-2

Definitions and Design Considerations... W-CR-2 General Information SECTION DIRECTORY Definitions and Design Considerations... W-CR-2 Combination Assembly Recommendations and Limitations Typical Sealant... W-CR-4 Single-Unit Opening... W-CR-4 Two-Way

More information

TABLE OF CONTENTS A. PBR

TABLE OF CONTENTS A. PBR TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl bay, bow and garden windows which incorporate an integral nailing fin. While the use of

More information

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS 2012 Pella Corporation INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS Part Number: 802L0105 Installation Instructions for Typical Wood Frame Construction. These instructions were developed tested

More information

Slate Shingle Specifications

Slate Shingle Specifications Slate Shingle Specifications California Slate is a proud member of the Slate Roofing Contractors Association of North America, Inc. (SRCA) which publishes Section 07310 Slate Shingles setting forth architectural

More information

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS 2012 Pella Corporation Part Number: 80WH0101 INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Installation Instructions for Typical Wood Frame Construction.

More information

12x12 Shed Plans and Building Guide

12x12 Shed Plans and Building Guide Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact

More information

INSTALLATION INSTRUCTIONS for Wood Patio Doors with Exterior Trim or Nailing Fin (JII026)

INSTALLATION INSTRUCTIONS for Wood Patio Doors with Exterior Trim or Nailing Fin (JII026) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood patio doors with exterior trim or nailing fin. Read these instructions thoroughly before

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

HydroGap Drainable Housewrap: Installation Instructions

HydroGap Drainable Housewrap: Installation Instructions METHOD I: MODIFIED O or CUT-BACK Method STEP 1 Unroll HydroGap Drainable Housewrap with blue spacers facing to the exterior and fasten to sheathing with nails, staples or cap fasteners. Fasteners should

More information

8x8 Shed Plans and Building Guide

8x8 Shed Plans and Building Guide Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact

More information

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT. FASTER. TIGHTER. ENERGY EFFICIENT. FROM THE CREATORS OF ZIP System Roof & Wall Sheathing INSTALLATION MANUAL Sales Office: 10925 David Taylor Dr., Suite 300 Phone: 800-933-9220 zipsystem.com Charlotte,

More information

1 Exam Prep Prov Module: Exterior Finishing Questions and Answers

1 Exam Prep Prov Module: Exterior Finishing Questions and Answers 1 Exam Prep Prov Module: 27204-13 Exterior Finishing Questions and Answers 1. From a safety standpoint, a carpenter's most important piece of clothing is probably. A. A long-sleeved shirt B. Work shoes

More information

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl bay, bow and garden windows which incorporate an integral nailing fin. Read these instructions

More information

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel This 8 12-ft. shed features a simple gable roof, double doors, and side and rear windows for natural lighting. With full-height walls and doors, there's ample room for storing large items or creating a

More information

Installation Instructions

Installation Instructions Installation Instructions HYDROGAP DRAINABLE HOUSEWRAP AND ACCESSORIES Page Basic Installation and Window Flashing: Pre-Installation Considerations 2 List of Approved Compatible Products 3 METHOD I: Modified

More information

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS Thank you for selecting C l i m a t e G u a r d products. Attached are our recommended installation instructions for Vinyl windows with an integral (2400-02) will not affect application of the ClimateGuard

More information

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs. Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm

More information

Technical Note No. 026

Technical Note No. 026 Technical Note No. 026 Strand Substrate Installed Vertically for Board & or Board-on-Board Applications This Technical Note is an addendum to the Strand Substrate Application Instructions and Trim and

More information

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016 Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support

More information

Vinyl Windows Manufactured by VPI Quality Windows

Vinyl Windows Manufactured by VPI Quality Windows Vinyl Windows Manufactured by VPI Quality Windows Part Number: 531&591 Installation 531 & 591 SERIES SLIDING AND HUNG WINDOW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction.

More information

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE 2 ND EDITION FLASHING SYSTEM FUNCTIONALLY UNIQUE. ENGINEERED PRODUCT SYSTEMS / FLASHING Fry Reglet comprehensive selection of moisture prevention

More information

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS This product can be used for interior and exterior installations. Much of this guide refers to exterior installation, however, many of the construction

More information