1 PRIVA-LITE Glass Instalation Guide Updated v 5.0

2 PRIVA-LITE? T TABLE OF CONTENTS 1. Fixed frame application Butt joint application 9 3. Door application Bathroom application Floor and ceiling application 13 1

3 1. FIXED FRAME APPLICATION Never expose the PRIVA-LITE to temperatures over 60 C Hot spots such as light spot, cooking table top may by consequence never be close to PRIVA-LITE panels. For external applications, PRIVA-LITE has to be assembled in DGU or TGU with low e glazing. It has to be assembled with solar control glazing in sunny countries or on South & West façades. 1.1 Frame characteristics PRIVA-LITE can be fixed in PVC, aluminium or timber frames. If the framing or the trimming are conductive (aluminium, lacquered or stainless steel, ), it is then necessary to ground it either on the earth of the building or on the earth terminals of the power supply unit. Make sure that allframing segments are interconnected. If not each segment must be independently connected to earth. Holes of 10mm of diameter have to be drilled in the frame to allow the female connectors of the glass cables to pass. The rebate height has to be min 18mm for PRIVA-LITE single glazing and min 20mm for PRIVA-LITE assembled in double glazing. When PRIVA-LITE is assembled in double glazing then please make sure that the frames are correctly drained and ventilated. Since PRIVA-LITE may not undergo a pressure of more than 10N/cm? make sure that the frame will be at least 4mm wider than the PRIVA-LITE panel. 2

4 1. FIXED FRAME APPLICATION 1.2 U Profile GLASS CABLE Length 100cm Diameter 5,5 mm +/-0.3mm + Molex female connector (8mm dia) EVA MOLDING MULTISIL SILICONE NON ACTIVE AREA 9mm GLASS LC FILM Top position MULTISIL SILCIONE U PROFILE SETTING BLOCK 3

5 1. FIXED FRAME APPLICATION 1.2 U Profile U PROFILE BottomPosition GLASS LC FILM NON ACTIVE AREA9mm MULTISIL SILICONE EVA MOLDING SETTING BLOCKS GLASS CABLE Length 100cm Diameter 5,5 mm +/-0.3mm + Molex female connector (8mm dia) 4

6 1. FIXED FRAME APPLICATION 1.3 U Profile + cavity GLASS CABLE Length 100cm Diameter 5,5 mm +/-0.3mm + Molex female connector (8mm dia) EVA MOLDING MULTISIL SILICONE NON ACTIVE AREA 9mm GLASS LC FILM Top position MULTISIL SILCIONE SETTING BLOCK 5

7 1. FIXED FRAME APPLICATION 1.3 U Profile + cavity GLASS LC FILM Bottomposition MULTISIL SILICONE NON ACTIVE AREA 9mm EVA MOLDING SETTING BLOCK GLASS CABLE Length 100cm Diameter 5,5 mm +/-0.3mm + Molex female connector (8mm dia) 6

8 1. FIXED FRAME APPLICATION 1.4 Installation in 5 steps Step 1 : Before fixing the PRIVA-LITE in its frame, make sure that the frame is clean and that a grommet has been fixed on each holes to prevent the damaging of the extension cable. Since PRIVA-LITE may not undergo a pressure of more than 10N/cm? make sure that the frame will be at least 4mm wider than the PRIVA-LITE panel. Step 2 : Pass the extension cables while making sure that the male connector of the cable is on the panel side Use only the extension cables delivered by Glassolutions Saint-Gobain between the power supply unit and the PRIVA-LITE panels. Step 3 : Connect the male connector of the extension cable to the female connector of the PRIVA-LITE panel. Make sure that connector is fully pushed in to get a good electrical insulation. Extension cable with Molex male connector Glass cable with Molex female connector 7

9 1. FIXED FRAME APPLICATION 1.4 Installation in 5 steps Step 4 : Place the PRIVA-LITE panel in its frame and wedge it with setting blocks. Only hard wood setting blocks may be used. Make sure that the thickness of the setting blocks is minimum 8mm to avoid crushing the EVA moulding, the connector and the cable. Step 5 : Sealing of the frame. Only the Multisil silicone delivered by Glassolutions Saint-Gobain and products approved by Saint-Gobain may come in to contact with the edges of the glass. Preformed sealing joints can be used unless they remain only in contact with the surface of the PRIVA-LITE. Step 5 : Sealing of the frame. In case of DGU, the outside sealing can be done with silicone DC993 and DC3362. But at the inner side, PRIVA-LITE s side, only the Multisil silicone delivered by Glassolutions Saint-Gobain can be used. EXTERIOR ELECTRODE PRIVA -LITE INTERIOR 76 NON ACTIVE AREA EVA MOLDING 8

10 2. BUTT JOINT APPLICATION When PRIVA-LITE panels are used as a glass wall without any vertical profiles (butt jointed glasses) then only the Multisil silicone delivered by Glassolutions Saint-Gobain may be used for joints. Available colours: Translucent, black (RAL 9005), grey (RAL 7042), white and brown (RAL 8019). Prior to silicone application, preferably place masking tape on both sides to obtain a neat joint, especially when edge is sandblasted. Remove masking tape before full reticulation of the silicone. To achieve a smooth butt joint finish, only use soapy water spray (neutral washing up liquid + water). Only products approved by Saint-Gobain may come in to contact with the edge of the glass. No other product such as glue, adhesive, sealant, gasket, plastic strip primer and finisher liquid can be used in contact with the edge. A min of 4mm separation between the panels is recommended. In case of bow, place bow in same direction for side by side panel and use 2 wooden blocks with a screw to middle height of the glass to move closer together the adjacent panels. 9

11 3. DOOR APPLICATION Never expose the PRIVA-LITE to temperatures over 60 C Hot spots such as light spot, cooking table top may by consequence never be close to PRIVA-LITE panels. For external applications, PRIVA-LITE has to be assembled in DGU or TGU with low e glazing. It has to be assembled with solar control glazing in sunny countries or on South & West façades. 3.1 Swinging and pivoting door For door application, PRIVA-LITE panel is either fixed in a frame or in top and bottom profiles (swinging door). Frameless PRIVA-LITE doors are impossible. In both cases, extension cables delivered by Glassolutions Saint-Gobain will have to pass through a lead cover such as Assa Abloy EA280 or EA281 Door handle and lock have to be fixed on the frame. Rectangular notch for the handle and the lock can be cut in the glass (and LC film) on demand and under specific conditions. If the lock has to work as a switch (PRIVA-LITE switched OFF when the door is locked), then the use a specific relays, such as the RSB relay from Schneider, is recommended. Electrical diagram is available on demand. For toilet door, we recommend to use our High Privacy PRIVA-LITE version (higher hiding power). Since PRIVA-LITE panel could slightly bend, we recommend to frame twin doors. Door handle and lock have to be fixed on the frame. Rectangular notch for the handle and the lock can be cut in the glass (and LC film) on demand and under specific conditions. If the lock has to work as a switch (PRIVA-LITE switched OFF when the door is locked), then the use a specific relays, such as the RSB relay from Schneider, is recommended. Electrical diagram is available on demand. For toilet door, we recommend to use our High Privacy PRIVA-LITE version (higher hiding power). Since PRIVA-LITE panel could slightly bend, we recommend to frame twin doors. 10

12 3. DOOR APPLICATION Never expose the PRIVA-LITE to temperatures over 60 C Hot spots such as light spot, cooking table top may by consequence never be close to PRIVA-LITE panels. For external applications, PRIVA-LITE has to be assembled in DGU or TGU with low e glazing. It has to be assembled with solar control glazing in sunny countries or on South & West façades. 3.2 Sliding door When PRIVA-LITE is used as a sliding door it has to be framed on 4 sides. Door handle and lock have to be fixed on the frame. Rectangular notch for the handle and the lock can be cut in the glass (and LC film) on demand and under specific conditions For sliding door application, a specific extension cable is needed. Please contact Glassolutions Saint-Gobain for more information. Extension cables delivered by Glassolutions Saint-Gobain will have to pass through an Energy chain system. For correct installation, follow Igus E-ChainSystem - Installation Guide.. 11

13 4. BATHROOM APPLICATION Always refer to CEI and most of all to National Electric Code Zone 0 (shower tray) : no PRIVA-LITE. Zone 1 (<120cm from water source) : only embedded DGU PRIVA-LITE IPX7 (PRIVA-LITE on the opposite side of bathroom). Zone 2 (>120cm from water source) : single glazing PRIVA-LITE IPX7 possible only if it s fixed in a frame perfectly sealed In case of bath, single glazing PRIVA-LITE IPX7 is possible only if it is fixed aside and above the bath tub in a frame perfectly sealed. A continuous cable has to be used between the panel and the power supply unit fixed out of the zones 0, 1 and 2. 12

14 5. FLOOR AND CEILING APPLICATION As PRIVA-LITE may not undergo pressure higher than 10N/cm? it has by consequence to be fixed as a second skin of a LITE-FLOOR panels. See drawing hereunder. See national regulation to define the thickness of the LITE-FLOOR panel Support structure will be visible through these transparent areas SGG LITE FLOOR PRIVA LITE Support structure Support structurehas to be min = to 1,5 the thickness of the SGG LITE FLOOR or PRIVA -LITE Never expose the PRIVA-LITE to temperatures over 60 C Hot spots such as light spot, cooking table top may by consequence never be close to PRIVA-LITE panels. For external applications, the SGG LITE-FLOOR has to be laminated with a solar control glazing as external glass and the area between the SGG LITE-FLOOR and PRIVA-LITE has to be correctly ventilated to avoid any overheating of the PRIVA-LITE 13

15 This document contains all essential instructions for the electrical installation of PRIVA-LITE panels on the power supply unit PVL XL. All documents previously published by Glassolutions are replaced by the present document. Glassolutions has taken every reasonable measure to ensure that the information contained in the present leaflet was exact at the time of its publication. However, Glassolutions keeps the right to modify or add any information without previous notice 14

Installation Instructions

Installation Instructions Installation Instructions Alcove Enclosure Before Installation please check that your shower enclosure system is undamaged Please read these instructions carefully March 2015 TOOLS REQUIRED Electric or

More information

EB/MM Upd.2_ CLIP-IN DOOR FOR SHOWERS FT

EB/MM Upd.2_ CLIP-IN DOOR FOR SHOWERS FT EB/MM Upd.2_20.06.16 CLIP-IN DOOR FOR SHOWERS FT 8570216 1 1 6 Working in partnership with Saint-Gobain Glassolutions, Adler SAS has developed Clip-In Door, a hinge that can be used to create glass doors

More information

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER NOTE: Acrylic wall, tray and tapware not included. Supplied handles may differ from image. SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied)

More information

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS ALLORA SWING PANEL INSTALLATION INSTRUCTIONS Before Installation Please check that your Allora Swing Panel is undamaged SEQUENCE OF INSTALLATION These instructions are also available from the Athena website:

More information

Deauville Installation Guide

Deauville Installation Guide vjul16 (for 17 or 24 mm Surface Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions

More information

ENARC CONSULTANTS. M. G. ROAD, THRISSUR - 1 Ph. : &

ENARC CONSULTANTS. M. G. ROAD, THRISSUR - 1 Ph. : & ENARC CONSULTANTS M. G. ROAD, THRISSUR - 1 Ph. : 2441901 & 2441905 SCHEDULE FOR INTERIOR FURNISHING WORK FOR RASMECC BRANCH (FIRST FLOOR) SBI, CONSTRUCTION OF BUILDING AT THRISSUR - 1 Fully Glazed Partitions

More information

Deauville Installation Guide

Deauville Installation Guide vjul16 (for Recessed Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions carefully before

More information

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray. Usage:

More information

B A T H R O O M G L A S S

B A T H R O O M G L A S S mistley B A T H R O O M G L A S S vaug16 Page 2 Thank you for purchasing this Trinity shower screen. Please study these instructions carefully before assembly and installation and check all supplied parts

More information

UNIT No FRAMELESS PIVOT SHOWER DOOR

UNIT No FRAMELESS PIVOT SHOWER DOOR INSTALLATION INSTRUCTIONS UNIT No. 3600 FRAMELESS PIVOT SHOWER DOOR NEED INSTALLATION HELP? Call 1-800-45-BASCO (452-2726) Monday - Friday 8:00 A.M. - 4:30 P.M. Eastern Time QCI0020 Rev. 3 Page 1 of 8

More information

Installation Instructions

Installation Instructions Installation Instructions Angle orner & Round Enclosures efore Installation please check that your shower enclosure system is undamaged Please read these instructions carefully Oct 2015 TOOLS REQUIRE Electric

More information

Hardware Fitting Accessories Door Seals

Hardware Fitting Accessories Door Seals Areas of application Protection against cold, draught and vermin Reduces light leakage, sound insulation Smoke control, fire resistance Reduces the energy consumption of air conditioning systems (see following

More information

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED ALCOVE SHOWER Your shower can be installed to open Left hand or Right hand by rotating

More information

Page 1 of Ch 6. A Lecture note on Building Technology By Kishor Thapa

Page 1 of Ch 6. A Lecture note on Building Technology By Kishor Thapa CHAPTER-6 Doors and windows 6.1 Doors: frames, shutters and their fixing details The function of a door is to give access to building and to different parts of the building and to deny the access whenever

More information

Updates Interior compensation of varying infill thicknesses. THERM + V curtain walls

Updates Interior compensation of varying infill thicknesses. THERM + V curtain walls Aluminium curtain wall from 10 to 24 can be compensated T12 = Depths from 25 Cover profile /15 013003 6 m Cover profile /12 013004 6 m Structural profile / V 113005 6 m Pressure profile 47 118005 6 m 011070.LI

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILDERS CHOICE FRAMED Shower Height Swing Door Model: L533 Rev. 09.03.13 MAINTENANCE: Two primary materials are used to manufacture your new Aquatic enclosure; tempered glass

More information

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY. Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY. IT IS RECOMMENDED TO USE A TRAINED SHOWER INSTALLER FOR THIS SHOWER TO OBTAIN THE BEST INSTALLATION. D Square

More information

VALENCIA RONDO DOOR WITH RETURN

VALENCIA RONDO DOOR WITH RETURN VALENCIA RONDO DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:

More information

Portofino Installation Guide

Portofino Installation Guide vjul16 (for 17 or 24 mm Surface Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Portofino shower enclosure. Please study these instructions

More information

Portofino Case2 Installation Guide

Portofino Case2 Installation Guide Portofino Case2 Installation Guide vjun16 (for 17 or 24 mm Surface Wall Profile) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Portofino Case 2 shower enclosure.

More information

ASS 70 FD folding/sliding door installation guide

ASS 70 FD folding/sliding door installation guide ASS 70 FD folding/sliding door installation guide 2 Preparation IMPORTANT These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the

More information

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE Set A Set B PFD30 Fire Door Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors IF INSTALLING A TOUCH LATCH, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS FIRST

More information

Architect: Daluz/González Architekten Photo: Peter Baracchi CP 155 SLIDING DOOR INSTALLATION GUIDE. Edition 15/21

Architect: Daluz/González Architekten Photo: Peter Baracchi CP 155 SLIDING DOOR INSTALLATION GUIDE. Edition 15/21 Architect: Daluz/González Architekten Photo: Peter Baracchi CP 155 SLIDING DOOR INSTALLATION GUIDE Edition 15/21 INDEX 1. IMPORTANT INFORMATION... 4 1.1. Lift & slide door overview... 5 1.2. Details...

More information

An adjacent sauna must be well insulated and located to leave a gap of at least 10 cm (4 ) for air to circulate between the sauna and the steam room.

An adjacent sauna must be well insulated and located to leave a gap of at least 10 cm (4 ) for air to circulate between the sauna and the steam room. Please read through these instructions carefully before starting assembly or installation work. There must be no form of heating in the steam room, apart from the steam itself. The ambient temperature

More information

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST Set A Set B PFD60 Fire Door Kit FITTING INSTRUCTIONS IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST SUGGESTED

More information

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE Set A Set B PFD30 SG Fire Door Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors SUGGESTED TOOLS DRILL G-CLAMP TAPE MEASURE (Image for reference only) HACKSAW POCKET

More information

Acid etched float glass

Acid etched float glass Description Acid etched float glass Golden Faith acid etched glass-non finger print has a uniformly smooth, silky surface, which is translucent and matte in appearance. It transmits levels of diffused

More information

In-line Patio Fabrication & Installation

In-line Patio Fabrication & Installation In-line Patio Fabrication & Installation Instructions 2 Pane Patio p2 Cutting and Preparation p2 Welding and Cleaning p2 Assembly p2 Fabrication Instructions for 3/4 Pane Lock Style p3 Installation (removable

More information

Installation - Sub Cills

Installation - Sub Cills Installation - Sub Cills Fitting of Subcill Drainage paths through the sub-cill can be seen on the illustration alongside so care must be taken to ensure they are not obstructed and that screw fixings

More information

INOVO 2-LITE SLIDING PATIO DOOR

INOVO 2-LITE SLIDING PATIO DOOR INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

340 & 350 SERIES BATH ENCLOSURES

340 & 350 SERIES BATH ENCLOSURES INSTALLATION INSTRUCTIONS 340 & 350 SERIES BATH ENCLOSURES 800-643-1514 www.alumaxbath.com Copyright Alumax Bath Enclosures 2010. All rights reserved. LIMITED WARRANTY AND REMEDY ALUMAX BATH ENCLOSURES

More information

340 & 350 SERIES DELUXE FRAMELESS BYPASS

340 & 350 SERIES DELUXE FRAMELESS BYPASS BATH ENCLOSURES An Alcoa Company Tel: 800-643-1514 Fax: 870-234-3181 www.alumaxbath.com INSTALLATION INSTRUCTIONS 340 & 350 SERIES DELUXE FRAMELESS BYPASS BATH ENCLOSURES Copyright Alumax Bath Enclosures

More information

Side Light Frame Pack Assembly Instructions

Side Light Frame Pack Assembly Instructions Please read this complete set of assembly instructions before starting the installation and only when you understand the construction method start to follow the step by step guide. IDENTIFY THE PACK CONTENTS

More information

INSTALLATION MANUAL 32273/1205 C C-403 GB - F - D - NL - ES - I - S - SLO

INSTALLATION MANUAL 32273/1205 C C-403 GB - F - D - NL - ES - I - S - SLO INSTALLATION MANUAL 32273/1205 C-402 - C-403 GB - F - D - NL - ES - I - S - SLO 1A 1B ENGLISH GENERAL INFORMATION The Cassette toilet is available in 2 types: C-402 Cassette toilet with built-in water

More information

INSTALLATION INSTRUCTIONS DANUBE ACRYLIC NEO ANGLE

INSTALLATION INSTRUCTIONS DANUBE ACRYLIC NEO ANGLE INSTALLATION INSTRUCTIONS DANUBE ACRYLIC NEO ANGLE March 2013 DOOR 2 Page 1 of 5 INSTALLATION INSTRUCTIONS NEO ANGLE 6MM FRAMELESS AND 4MM FRAMED SHOWER DOOR DANUBE, DELTA, SIGNATURE, OCEANIA, CASCADE

More information

FIG. #1 - ASD-90 & USD-90 Shower Door Assembly

FIG. #1 - ASD-90 & USD-90 Shower Door Assembly Installation Instructions for the Accent/Euro Collection FIG. #1 - ASD-90 & USD-90 Shower Door Assembly #1021 #1021 1 23 25 2 #1020 6 5 12 #1020 9 24 9 8 Hinge Assembly 2109, 2201, 2212, 2213, 2220 7 Please

More information

CINTRALUX ALU BARREL VAULT EP 10/10

CINTRALUX ALU BARREL VAULT EP 10/10 CINTRALUX ALU BARREL VAULT EP 10/10 Installation instructions EN 14963 Artn 43984 E_MH_Cintralux EP 10/10 mm AG.PLASTICS QUALITY 1 Installation instructions Cintralux aluminium barrel vault: Cintralux

More information

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A 1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A F AB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Fax: (614)-334-4919 Office Timing: 8:30-18:00 EST info@fabglassandmirror.com

More information

Side Light Frame Pack Assembly Instructions

Side Light Frame Pack Assembly Instructions Side Light Frame Pack Assembly Instructions Please read this complete set of assembly instructions before starting the installation and only when you understand the construction method start to follow

More information

Method of Build 1. General

Method of Build 1. General Method of Build 1 General GLAZED ELEVATIONS Viso Double Glazed in glazed form differs from many other systems as the vertical joints can have Viso dry joints or the unique HIDDEN mullion post between glazed

More information

Platinum Swing Panel Installation Instructions

Platinum Swing Panel Installation Instructions Platinum Swing Panel Installation Instructions The Standard Platinum Swing Panel is designed to fit baths with a perimeter lip no taller than 20mm. If installing onto baths without a perimeter lip an optional

More information

ASS 70 FD folding / sliding door. Installation Guide

ASS 70 FD folding / sliding door. Installation Guide ASS 70 FD folding / sliding door Installation Guide IMPORTANT! These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the installation.

More information

IMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions)

IMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions) ASSEMBLY ASSEMBLY INSTRUCTIONS (Internal Dimensions) Ent Spec Edition Ltr v-0- Overall dimensions including base: 7. L x 9 W x 0 H cms 97.5" L x 7" W x 8.7" H IMPORTANT!!! Please read these instructions

More information

SHOWERLUX HELPLINE: TEL: SHOWERLUX (UK) Ltd.

SHOWERLUX HELPLINE: TEL: SHOWERLUX (UK) Ltd. SHOWERLUX HELLIE: TEL: 02476 882518 Fax: 02476 882539 Email: technical@showerlux.co.uk Email: spares@showerlux.co.uk SHOWERLUX (UK) Ltd. Sibree Road, Coventry, West Midlands CV3 4FD Tel: 02476 639400 Fax:

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760

Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760 Lightway, s.r.o. Registered office: Ledvinova 1714, 149 00 Praha 4 Offices: Za Humny 1054/4a, 161 00 Praha 6 tel.: 235 300 694, fax: 235 300 218 Company ID No.: 63669366, Tax ID No.: CZ63669366 Bank: KB

More information

Prel-Lam LC-LTI Liquid Crystal Laminated Glass

Prel-Lam LC-LTI Liquid Crystal Laminated Glass Prel-Lam LC-LTI Liquid Crystal Laminated Glass 1. FEATURES Liquid crystal glass is laminated glass that is connected to a switch-operated electric circuit. The appearance of this glass changes depending

More information

SUPREME WALL GARDEN ASSEMBLY INSTRUCTIONS 24/08/16 www.hallsgreenhouses.com Please refer to website for the most up to date instructions. SAFETY WARNING 1. Always wear protective glasses, shoes, gloves

More information

Standard program overview Steel smoke-proof doors

Standard program overview Steel smoke-proof doors Smoke-proof doors Standard program overview Steel smoke-proof doors Pos. Product 1 RS-1 Steel door (thin rebated) Smoke-proof door in accordance EN 1634-3 / DIN 18095 Dimensions W 625-1350 H 1750-2500

More information

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 1/4 FRAMELESS SLIDING DOOR FOR OR SHOWER INSTALLATION INSTRUCTIONS NEED INSTALLATION HELP? Call 1-800-45-BASCO (452-2726) M onda y - Friday 8 :00 A.M. - 4:30 P.M. Eastern Time MAINTENANCE: Two primary

More information

FACTS ABOUT TP LITE FRAMELESS P

FACTS ABOUT TP LITE FRAMELESS P FRMELESS PRTITION FCTS OUT TP LITE TP Lite is a frameless fully glazed partition system with a single glass layer TP Lite with door frames ensures sound reduction that meets normal sound demands for meeting

More information

mistley PELE Installation Guide vapr16 Mistley Bathroom Glass Limited No 4 One Mistley Quayside, High Street, Mistley, Essex CO11 1AL England

mistley PELE Installation Guide vapr16 Mistley Bathroom Glass Limited No 4 One Mistley Quayside, High Street, Mistley, Essex CO11 1AL England mistley BAT HRO O M G LASS vapr16 Page 2 Thank you for purchasing this Pele shower screen. Please study these instructions carefully before assembly and installation and check all supplied parts immediately

More information

FIG. #1 - ASD & USD 180/280 Shower Door Assembly

FIG. #1 - ASD & USD 180/280 Shower Door Assembly FIG. #1 - ASD & USD 180/280 Shower Door Assembly USD180 / 280 Euro Stall Header #1020 16 16 1 16 4 ASD180 / 280 Accent Stall Header #1021 5 3 8 6 7 8 Hinge Assembly: 2220, 2201, 2185, 2271, 2213 18 22

More information

VALENCIA CORNER DOOR WITH RETURN

VALENCIA CORNER DOOR WITH RETURN VALENCIA CORNER DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:

More information

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION SLIMLINE STEP-BY-STEP INSTALLATION GUIDE Thank you for choosing Roof Maker, we hope you are delighted with your new rooflight. Our roof lanterns

More information

Exploded View PAGE 2 OF 9

Exploded View PAGE 2 OF 9 Argon 02 Exploded View PAGE 2 OF 9 Supplied Parts Underframe Underframe Insert Wall to Glass Hinge Door Handle Door Bottom Seal Hinge Seal Bubble Seal PAGE 3 OF 9 Important Information This shower screen/enclosure

More information

SLIDING DOOR for CORNER installation ONLY - this door closes to side panel -

SLIDING DOOR for CORNER installation ONLY - this door closes to side panel - by KUDOS INSTALLATION INSTRUCTIONS SLIDING DOOR for CORNER installation ONLY - this door closes to side panel - Please read these instructions throughout before installing as incorrect fitting will invalidate

More information

Monaco Installation Guide - Surface Profiles

Monaco Installation Guide - Surface Profiles v1 Page 1 Thank you for purchasing this Monaco shower screen. Please study these instructions carefully before assembly and installation and check all supplied parts immediately upon receipt. These instructions

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS EDGE PIVOT DOOR EPDSC0760 EPDSC0800 EPDSC0900 EPDSC1000 ESPSC0760 ESPSC0800 ESPSC0900 ESPSC1000 PIVOT DOOR IN ALCOVE PIVOT DOOR & SIDE PANEL INSTALLATION INSTRUCTIONS IMPORTANT - Please read before installation

More information

SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE

SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE Please read guide before beginning any installation. Instructions/Guides Keys & Handle Screw Covers Interlock Covers Anti-Lift & Rubber Stops Anti-Lift for Slim

More information

How To Install Windows: Nail-Fin Application

How To Install Windows: Nail-Fin Application How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:

More information

INFINITE RANGE - CENTRE FOLDING DOOR

INFINITE RANGE - CENTRE FOLDING DOOR INFINITE RANGE - CENTRE FOLDING DOOR CENTRE FOLDING DOOR ONLY ( RECESS) Please read these instructions before installing, as incorrect fitting will invalidate the guarantee-carry out each stage before

More information

For Installer. Duration Windows. Assembly Guide Durafold 1000

For Installer. Duration Windows. Assembly Guide Durafold 1000 For Installer Assembly Guide Durafold 1000 Contents Title Page Number Handling Manual Blinds 4 Handling Electronic Blinds 5 Drainage 63 Outer Frame Assembly (Kit Form Door Only) 7 15mm Low Threshold Assembly

More information

Gluing windows with SABA Glasstack 760

Gluing windows with SABA Glasstack 760 Info sheet 208 Gluing windows with SABA Glasstack 760 Version 2008-05-08 EN, replaces all prior versions Page 2 of 9 Info sheet 208 Gluing windows with SABA Glasstack 760, version 2008-05-08 EN 1. Introduction

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

PREMIUM GLASS BATH SCREEN

PREMIUM GLASS BATH SCREEN PREMIUM GLASS BATH SCREEN INSTALLATION GUIDE Bath screens must be installed in situations where the floor of the bathroom has a waterproof membrane installed. For New Zealand, the bath screen must be installed

More information

SEMI-FRAMELESS DOOR WITH GLASS PANEL & BENCH GLASS

SEMI-FRAMELESS DOOR WITH GLASS PANEL & BENCH GLASS INSTALLATION INSTRUCTIONS 1-800-669-9867 800-643-1514 www.alumaxshowerdoor.com SEMI-FRAMELESS DOOR WITH GLASS PANEL & BENCH GLASS 395CV-1217 Yes! Guaranteed Forever! Proudly Made in Kansas, USA 202 Anderson

More information

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A 1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A F AB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Fax: (614)-334-4919 Office Timing: 8:30-18:00 EST info@fabglassandmirror.com

More information

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that

More information

Simplex Baseboard System Baseboard System

Simplex Baseboard System Baseboard System Simplex Baseboard System Baseboard System I Complete installation programme I Trouble-free and time-saving installation I Various connection kits for all types of pipe Our service to you I Simplex Products

More information

Semi-Frameless Hinged Door With Panel And Return

Semi-Frameless Hinged Door With Panel And Return 202 Anderson Ave., Belvue, KS 66407 Phone: 800-669-9867 Fax: 800-393-6699 www.onyxcollection.com 800-643-1514 www.alumaxbath.com Semi-Frameless Hinged Door With Panel And Return Full Showers with Return

More information

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

How to Build Your Custom Teardrop Camper. 5 x 10 Trailer. 5 Tall Cabin

How to Build Your Custom Teardrop Camper. 5 x 10 Trailer. 5 Tall Cabin How to Build Your Custom Teardrop Camper 5 x 10 Trailer 5 Tall Cabin Contact: hennesseystealth@bigteardrop.com http://www.bigteardrop.com ebay Seller ID: hennesseystealth1957 United States Copyright TXu

More information

INSTALLATION MANUAL FORTRESS SERIES

INSTALLATION MANUAL FORTRESS SERIES Guardian Security Structures TEL 1-406-212-2334 EMAIL rg@gssdoors.com WEB www.gssdoors.com FORTRESS SERIES GENERAL INSTALLATION GUIDELINES 1. The door frame is installed using 16 bolt screws 7,5 mm in

More information

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 1/4 FRAMELESS SLIDING DOOR FOR OR SHOWER INSTALLATION INSTRUCTIONS NEED INSTALLATION HELP? Call 1-800-45-BASCO (452-2726) M onda y - Friday 8 :00 A.M. - 4:30 P.M. Eastern Time MAINTENANCE: Two primary

More information

Glues and mastics. SILICONE ADHESIVE SEALANT 42 Marine silicone SOROMAP...42 Silicone colour RAL...42 Glue mastic MS1000 TECHNIFIX...

Glues and mastics. SILICONE ADHESIVE SEALANT 42 Marine silicone SOROMAP...42 Silicone colour RAL...42 Glue mastic MS1000 TECHNIFIX... Glues and mastics In this chapter, we present all the products that you need to make sticking, seals, insulation and teak deck. SILICONE ADHESIVE SEALANT 42 Marine silicone SOROMAP......................................42

More information

Dubnium 11 Installation Instructions & Parts List

Dubnium 11 Installation Instructions & Parts List Dubnium 11 Installation Instructions & Parts List Illustration Dubnium, H1 Handle Right Hand: Open Out Page 1 of 25 IMPORTANT This shower screen / enclosure must be installed by suitably qualified individuals.

More information

Showerlux roduct made by The Duscholux Group Showerlux Spares Shop www.showersealspares.co.uk Due to a policy of continuous improvement and product development, Duscholux reserves the right to amend specification

More information

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure: tempered glass and anodized

More information

Table and Furniture Base Fittings Plinth Adjusting Fittings

Table and Furniture Base Fittings Plinth Adjusting Fittings Adjusting screw with M8 or M thread Rigid, for glide inserts, steel thread Finish/Colour: Black, thread galvanized Version: With acceptance Ø30 mm Thread M8 650.22.381 M 650.22.382 Packing: 1 or 0 pcs.

More information

CORNER ENTRY ENCLOSURE

CORNER ENTRY ENCLOSURE CORNER ENTRY ENCLOSURE SUPREME INSTALLATION INSTRUCTIONS IMPORTANT - Please read before installation Please read these instructions carefully before starting installation and keep in a safe place for future

More information

Gallium 03 Installation Instructions & Parts List

Gallium 03 Installation Instructions & Parts List Gallium 03 Installation Instructions & Parts List Illustration Gallium 03, H1 Handle Left Hand: Open Out 04/05/2016 Revision 1.1 Page 1 of 19 IMPORTANT This shower screen / enclosure must be installed

More information

Liniar Window. installation guide

Liniar Window. installation guide Liniar Window installation guide This installation guide is designed to show you the best way to fit Liniar windows, and covers all styles of window made from Liniar s lead-free 70mm PVCu profile. Not

More information

PATIO INSTALLATION MANUAL

PATIO INSTALLATION MANUAL PATIO INSTALLATION MANUAL A few minutes spent reviewing the following instructions will help insure quick and proper assembly. The Patio Sauna Kit will arrive on a stretchwrapped pallet including pre-built

More information

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 0º PANEL This instruction sheet applies to the following units. C, C7, C7, C77, C, C7 This instruction sheet also applies to the following units. VTE / VSE

More information

28.00 Rmt sqm sqm

28.00 Rmt sqm sqm SEALED BID FORMAT FOR THE INTERIOR FURNISHING WORKS AT SBI CHALAKUDY BRANCH. Sl No. Description of item Quantity Unit Rate Amount 1 Counter Table :- The width and height of the table is 100cm and 75cm

More information

INFINITE RANGE - HINGE DOOR

INFINITE RANGE - HINGE DOOR INFINITE RANGE - HINGE DOOR HINGE DOOR + 1 SIDE RETURN PANEL (CORNER) Please read these instructions before installing, as incorrect fitting will invalidate the guarantee-carry out each stage before moving

More information

SERIES 3070-T MULTI-SLIDE ASSEMBLY & INSTALLATION INSTRUCTIONS

SERIES 3070-T MULTI-SLIDE ASSEMBLY & INSTALLATION INSTRUCTIONS Table of Contents I. Care and Maintenance...2 II. Tools / Material & Sealant Requirements...2 III. Assembly and Installation...2 IV. Glazing Assembly...3 V. Panel Assembly...3 1. X Panel...3 2. O Panel...4

More information

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2 Evolve bi-fold Installation Guide 1. Before you start p2 8. Door restrictor- optional p9 2. Measuring and surveying p2 3. Configuration details p4 4. Installation p5 5. Glazing p5 6. Glazing packer details

More information

argenta opening doors

argenta opening doors invisidoor Invisible aluminium frame for interior doors Content invisidoor... 4 invisidoor AX / AX PRO... 10 invisidoor SD / SDX... 16 invisiplint... 22 general information... 27 THE INVISIDOOR CONCEPT

More information

3/16 OR 1/4 FRAMELESS SWING DOOR WITH SINGLE INLINE PANEL OR TWO INLINE PANELS

3/16 OR 1/4 FRAMELESS SWING DOOR WITH SINGLE INLINE PANEL OR TWO INLINE PANELS / OR / FRAMELESS SWING DOOR WITH SINGLE INLINE OR TWO INLINE S This instruction sheet applies to the following units with a magnetic handle. C7, C7, C79 This instruction sheet also applies to the following

More information

Installation Instructions Student 101 Fume Cupboard

Installation Instructions Student 101 Fume Cupboard Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing

More information

Side and rear window, assembly overview

Side and rear window, assembly overview 64-7 Side and rear window, assembly overview 1 - Side/rear window Removing Unbroken Page 64-9 Broken Page 64-11 Installing Page 64-13 Curing time Page 64-21 Re-sealing Page 64-25 2 - PUR adhesive sealant

More information

TOYOTA MOTOR EUROPE CA Products Division Tel : Fax :

TOYOTA MOTOR EUROPE CA Products Division Tel : Fax : TOYOTA MOTOR EUROPE CA Products Division Tel : + 32 2 745 26 77 Fax : + 33 2 745 26 99 Ordering part numbers Comments Part Numbers Wooden floor one hatch PZ449-D3C42-11 one hatch with carpet PZ449-D3C42-01

More information

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT 821 811 342 821 835 853 863 840 12.5mm Plasterboard 837 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims Note: For clarity the cavity infill has not been shown 854 342

More information

Method of Build 1. Fire. Sound

Method of Build 1. Fire. Sound Method of Build 1 General Viso Fire & Acoustic in the solid form differs from most other systems as it can be erected using 12.5mm & 15.0mm boards within the same Aluminium framework. Also hidden fix board

More information

Panel Installation Instructions

Panel Installation Instructions EXTREMELY IMPORTANT INFORMATION PLEASE READ ENTIRE PACKET! Warranty Is Void If Panels Not Installed According to Instructions 1. WARNINGS & SPECIAL NOTES 1.1 Keep panels 24 from Heaters and shield Radiant

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information