Series 960 wall storefront. Installation Instructions

Size: px
Start display at page:

Download "Series 960 wall storefront. Installation Instructions"

Transcription

1 Series 960 wall storefront Installation Instructions Part NO. Y005 February 2013

2 960 WALL TALE OF CONTENTS JWH 8/2011 SECTION I II III GENERAL NOTES PARTS IDENTIFICATION SCREW SPLINE FARICATION PAGE 1 PAGE 2-17 PAGE IV SHEAR LOCK FARICATION PAGE V SCREW SPLINE and SHEAR LOCK FARICATION VIII IX A) COVERS AND WEEPS PAGE ) GLASS SETTING CHAIR and 1/4" / 1/2" ADAPTORS PAGE 37 C) SYSTEM II WINDOW ADAPTORS PAGE 38 VI DOOR FRAME INSTALLATION PAGE VII SILL FLASHING INSTALLATION PAGE SCREW SPLINE and SHEAR LOCK INSTALLATION A) FRAME ANCHORING ) GLASS SETTING CHAIR ASSEMLY C) L126 WATER DEFLECTOR for 1" GLAZING D) TYPICAL DETAIL SHOWING PARTS RELATIONSHIP E) 1/4" & 1/2" GLAZING ADAPTORS w/ L129 DEFLECTOR F) TYPICAL DETAIL SHOWING PARTS RELATIONSHIP G) UL GASKET INSTALLATION H) SYSTEM II WINDOW ADAPTOR STRUCTURAL SILICONE GLAZED MULLION INSTALL PAGE 45 PAGE 46 PAGE PAGE 49 PAGE PAGE PAGE 55 PAGE 56 X GLAZING PAGE A) GLASS SIZE & GLASS SETTING PAGE 61 ) TEMPORARY GLAZING USING CLIPS & COVERS PAGE 62 C) TEMPORARY GLAZING USING CLIPS & COVERS w/ STRUCTURAL SILICONE GLAZED MULLION PAGE 63 Minimizing Condensation NOTE: Please reference EFCO's "Understanding Condensation" brochure which can be obtained through your EFCO representative. Condensation will form on any surface when unfavorable conditions (interior temperature and relative humidity and exterior temperature) are present. When the formation of excessive condensation is a concern, it is highly recommended that a design professional is utilized to perform an analysis of the shop drawings to recommend the best installation methods. Please contact EFCO representative for information on EFCO's Thermal Analysis Services. Many current installation practices lead to an increase in the possibility of the formation of condensation. Though not all inclusive, the list of examples below illustrates conditions under which condensation is likely to occur: 1. ridging system thermal break with non-thermally broken metal flashing or lintels that are exposed to the exterior. 2. System exposure to cold air cavities. 3. Interior relative humidity levels not maintained at recommended levels, see EFCO's "Understanding Condensation" brochure. 4. Inadequate separation between system and surrounding condition at perimeter. 5. Product combinations during the shop drawing stage that result in bridging thermal breaks of one or all products involved.

3 PAGE 1 SECTION I - GENERAL NOTES 1) EFCO Series 960 Wall is a thermal wall system with a 1 3/4" face dimension and has system depth dimensions from 2 3/4" to 8 1/8". The system is exterior glazed with either 1/4" or 1" dry glazing. Entrance doors are an engineered part of the system. Check the shop drawings, installation instructions, and the glazing instructions to become thoroughly familiar with the project. The shop drawings take precedence and include specific details for the project. The installation instructions are of a general nature and cover the most common conditions. 2) Check all materials upon arrival and be sure you have everything required to begin installation. (See Section II "PARTS IDENTIFICATION") 3) 4) All work should start from bench marks and/or column center lines as established by the architectural drawings and the general contractor. Check construction for compliance with the contract documents. Sealants must be compatible with all surfaces. Consult with the sealant manufacturer for recommendations regarding compatibility and adhesion. 5) All materials are to be installed plumb, level, and true. 6) Protect aluminum materials after erection. Cement, plaster, alkaline solutions, and acid based materials can be harmful to the finish. 7) Clean all finished aluminum surfaces with a mild detergent and water. No abrasive agent should be used.

4 PERIMETER ACK MEMERS COVERS /8" /4" /8" " PERIMETER COMPONENTS and COMINATIONS 1 9/16" (SHEAR LOCK 0NLY) 3 1/2" 4 1/8" 4 1/2" 4 7/8" /16" 4 1/2" 5 1/2" 5 7/8" /16" 6" 5 1/8" 6 5/8" 7" 7 3/8" FOR 1" GLAZING (USE H260 ISOLATOR) /16" 6 3/4" 7 3/8" 7 3/4" 8 1/8" SECTION II - PARTS IDENTIFICATION PAGE 2

5 MULLION COMPONENTS AND COMINATIONS MULLIONS COVERS /8" /4" /8" " 1 9/16" 3 1/2" 4 1/8" 4 1/2" 4 7/8" 9608 (SHEAR LOCK ONLY) 2 9/16" 4 1/2" 5 1/8" 5 1/2" 5 7/8" /16" 6" 6 5/8" 7" FOR 1" GLAZING (USE H260 ISOLATOR) /16" 6 3/4" 7 3/8" 7 3/4" 7 3/8" 8 1/8" CONT. SECTION II - PARTS IDENTIFICATION PAGE 3

6 MULLION COMPONENTS AND COMINATIONS SPLIT MULLIONS COVERS /8" /4" /8" " 2 9/16" 4 1/2" 5 1/8" 5 1/2" 5 7/8" /16" 6" 6 5/8" 7" 7 3/8" FOR 1" GLAZING (USE H260 ISOLATOR) 4 13/16" 6 3/4" 7 3/8" 7 3/4" 8 1/8" CONT. SECTION II - PARTS IDENTIFICATION PAGE 4

7 PERIMETER ACK MEMERS COVERS /8" /4" /8" PERIMETER COMPONENTS and COMINATIONS 1 9/16" 2 3/4" 3 3/8" 3 3/4" /8" 2" 9620 (SHEAR LOCK ONLY) /16" 4 1/16" 3 3/4" 4 3/8" 4 3/4" 5 1/8" 5 1/4" 5 7/8" 6 1/4" 6 5/8" FOR 1/4" GLAZING (USE H261 ISOLATOR) /16" 6" 6 5/8" 7" 7 3/8" CONT. SECTION II - PARTS IDENTIFICATION PAGE 5

8 COVERS MULLION COMPONENTS AND COMINATIONS MULLIONS /8" /4" /8" " /16" (SHEAR LOCK ONLY) 2 3/4" 3 3/8" 3 3/4" 4 1/8" 2 9/16" 3 3/4" 4 3/8" 4 3/4" 5 1/8" /16" 5 1/4" 5 7/8" 6 1/4" 6 5/8" FOR 1/4" GLAZING (USE H261 ISOLATOR) 6" /16" 6 5/8" 7" 7 3/8" CONT. SECTION II - PARTS IDENTIFICATION PAGE 6

9 MULLION COMPONENTS AND COMINATIONS SPLIT MULLIONS COVERS /8" /4" /8" 2 9/16" 3 3/4" 4 3/8" 4 3/4" " 5 1/8" /16" 5 1/4" 5 7/8" 6 1/4" 6 5/8" FOR 1/4" GLAZING (USE H261 ISOLATOR) /16" 6" 6 5/8" 7" 7 3/8" CONT. SECTION II - PARTS IDENTIFICATION PAGE 7

10 F960 WALL MDM 04/06 CORRESPONDING MULLION LENGTHS SSG TO CAPTURED ADAPTOR HORIZ.TO VERT. SHEAR LOCK 1/4" GLAZING ADAPTOR USE WM11 TAPE & SFZ4 #8-15 X 1 1/4 PL-FH-SMS 18-8 A UTT GLAZE TAPE WM11 UTT GLAZED MULLIONS 2 9/16".M. 3/8" 9635 K347 CLEAR K348 RONZE /16".M. SFZ4 ADHESIVE ADHESIVE 9662 K349 CLEAR K350 RONZE WM11 FOR 1/4" & 1" GLAZING 4 13/16".M. 16C2/16C1 K351 CLEAR K352 RONZE CONT. SECTION II - PARTS IDENTIFICATION PAGE 8

11 DOOR HEADERS & JAMS 960 Wall KDE 10/2002 CORRESPONDING MULLION LENGTHS DOOR HEADERS (2 1/2" SIGHT LINE) (w/ 5/8" COVER) DOOR HEADER SHEAR LOCKS (7093) DOOR JAMS (1 3/4" SIGHT LINE) (w/ 5/8" COVER) DOOR JAM SHEAR LOCKS (FOR HEADER APPLICATION) SURFACE CLOSER TRANSOM JAM GLAZING 9673 / 9674 ACK MEMER K333 RH CLR. K334 LH CLR. K335 RH RZ. K336 LH RZ K337 CLR. K338 RZ EXTERIOR 2 9/16" /2" 4.500" INTERIOR FOR 1" GLAZING /16" ACK MEMER " K325 RH CLR. K326 LH CLR. K327 RH RZ. K328 LH RZ " 9639 K194 CLR. K195 RZ K444 CLR. K445 RZ. CONT. SECTION II - PARTS INDENTIFICATION PAGE 9

12 DOOR HEADERS & JAMS FOR 1" GLAZING 960 Wall KDE 10/2002 CORRESPONDING MULLION LENGTHS DOOR HEADERS (2 1/2" SIGHT LINE) DOOR HEADER SHEAR LOCKS (7093) DOOR JAMS (1 3/4" SIGHT LINE) DOOR JAM SHEAR LOCKS (FOR HEADER APPLICATION) SURFACE CLOSER TRANSOM JAM GLAZING 9673 / /16" ACK MEMER EXTERIOR /8" (w/ 1 1/4" COVER) K325 RH CLR. K326 LH CLR. K327 RH RZ. K328 LH RZ " (w/ 1 1/4" COVER) K194 CLR. K195 RZ. K341 CLR. K342 RZ INTERIOR /16" ACK MEMER K329 RH CLR. K330 LH CLR. K331 RH RZ. K332 LH RZ " (w/ 5/8" COVER) /4" (w/ 5/8" COVER) " (w/ 1 5/8" COVER) K194 CLR. K195 RZ " 9657 (w/ 2" COVER) K341 CLR. K342 RZ. CONT. SECTION II - PARTS IDENTIFICATION PAGE 10

13 CORRESPONDING MULLION LENGTHS DOOR HEADERS (2 1/2" SIGHT LINE) DOOR HEADER SHEAR LOCKS (7093) DOOR JAMS (1 3/4" SIGHT LINE) DOOR JAM SHEAR LOCKS (FOR HEADER APPLICATION) SURFACE CLOSER TRANSOM JAM GLAZING 9673 / /16".M /4" (w/ 5/8" COVER) K369 RH RZ. K370 LH RZ. K371 RH CLR. K372 LH CLR. DOOR HEADERS & JAMS FOR 1/4" GLAZING " (w/ 5/8" COVER) K194 CLR. K195 RZ EXTERIOR ADAPTOR INTERIOR CONT. SECTION II - PARTS IDENTIFICATION PAGE 11

14 960 WALL KDE 10/ /2" SIGHT LINE " SIGHT LINE 9681/ SPLAYED MULLION & COVER OPTIONAL CUSTOM APPLICATION EXTRUSIONS 6.000" 3.500" 8940/ COLOR DOOR JAM #1G43 DOOR JAM SHEAR LOCK (FOR HEADER APPLICATION) 8940/ COLOR DOOR JAM #1G42 DOOR JAM SHEAR LOCK (FOR HEADER APPLICATION) SURFACE CLOSER FOR THERMASTILE DOORS (2" THICK ONLY) 6.000" (w/ 5/8" COVER) 4.500" K324 - CLR K447 - RZ (w/ 5/8" COVER) K323 - CLR K446 - RZ CONT. SECTION II - PARTS IDENTIFICATION PAGE 12

15 STANDARD SILL FLASHINGS w/end CAPS ACK MEMER 3.213" SPLICE JOINT # F542 END CAP PKG. 1 9/16".M " # /16" TRIMMED LEG K479 (1) FT78, (2) SFP " 2 9/16".M " # /4" TRIMMED LEG K480 (1) FT79, (2) SFP " 4 1/16".M " # /16" TRIMMED LEG K481 (1) FT80, (2) SFP " 4 13/16".M " # /16" AS SUPPLIED K482 (1) FT81, (2) STC7 F960 WALL PAGE 13 JWH 2012

16 8487 / INSIDE 8488 / OUTSIDE 135 DEGREE INSIDE AND OUTSIDE CORNER MULLIONS /2" SYSTEM DEPTH 6" SYSTEM DEPTH " 4.500" 4.500" 2.188" 8485 / INSIDE 8486 / OUTSIDE FOR 1" GLAZING (USE H260 ISOLATOR) 1.188" 6.000" 6.000" 2.750" CONT. SECTION II - PARTS IDENTIFICATION PAGE 14

17 960 WALL MDM 04/06 4 1/2" SYSTEM DEPTH 6" SYSTEM DEPTH 8477 / INSIDE CORNER MULLION 8477 / INSIDE CORNER MULLION SHEAR LOCK REQ'D = K /2" SYSTEM DEPTH 6" SYSTEM DEPTH 8474 / OUTSIDE CORNER MULLION 8474 / OUTSIDE CORNER MULLION DEGREE INSIDE AND OUTSIDE CORNER MULLIONS FOR 1" GLAZING USE H260 ISOLATOR SHEAR LOCK REQ'D = K SHEAR LOCK REQ'D = K SHEAR LOCK REQ'D = K /4" SYSTEM DEPTH 8474 / 16C3 90 OUTSIDE CORNER MULLION C SHEAR LOCK REQ'D = K CONT. SECTION II - PARTS IDENTIFICATION PAGE 15

18 SYSTEM 960 WALL ACCESSORIES LIST PAGE 16 SECTION II - PARTS IDENTIFICATION CONT. K /16" ACK MEMERS K170 K147 K /16" 4 1/16" 4 13/16" ACK MEMERS ACK MEMERS ACK MEMERS HN89 HN92 SETTING LOCK & CHAIR K148 1/4" GLAZING K149 1" GLAZING SETTING LOCKS ARE TO E ATTACHED THERMAL ISOLATOR CLIPS H261 1/4" GLAZING H260 1" GLAZING SETTING LOCKS HN80 HEP1 H157 1/4" OR 1/2" DOOR HEADER 1" SETTING DOOR HEADER POCKET FILLERS 1" GLAZING /4" GLAZING " SETTING 1G42 & 1G43 AS TRANSOM AR WATER DEFLECTORS FRAME GLASS ADAPTORS 1/4" GLASS ADAPTOR 9649 AT VERTICALS & SIDELITES /4" GLASS ADAPTOR w/ L129 1/2" GLASS ADAPTOR w/ L129 AT HORIZONTALS w/ WATER DEFLECTORS DOOR FRAME GLASS ADAPTORS 1/4" GLASS ADAPTOR FOR DOOR FRAMES TRANSOM JAM GLAZING ADAPTOR L129 1/4" GLASS & 1/2" GLASS USE w/ ADAPTORS EXTERIOR 9673 INTERIOR L126 L130 FOR 1" GLAZING w/ H260 FOR 1/4" GLAZING w/ H261 1/2" GLASS ADAPTOR FOR DOOR FRAMES 9734 F960 WALL JDA 5/2002

19 SYSTEM 960 WALL ACCESSORIES LIST PAGE 17 SECTION II - PARTS IDENTIFICATION CONT. H457 CD CD CD CD SCREW SPLINE & SHEAR LOCK DRILL FIXTURE HORIZ. TO SHEAR LOCK W115 W125 W143 W127 UL UNDERSIZED GLASS.875" TO.906" OVERSIZED GLASS or GRID OTH SIDES WEDGE GASKET (DOOR FRAME-EXT.) STT7 #10-12 X 1 PL-PH-SMS 18-8 A 1/4" & 1/2" GLAZING ADAPTOR SPP8 #8-15 X 3/4 PL-PH-SMS 18-8 A 9666 & /4" & 1/2" GLAZING ADAPTOR FOR JAMS & TRANSOMS WM11 UTT GLAZE SPACER 3/8" x 1/2" TAPE SCREW SPLINE FASTENERS S108 #8-18 X 1 SL-HW-SMS -LEAD POINT SHEAR LOCK FASTENERS MRF8 #10-24 X 1 3/4 PL-PH-SMS 410 F STU8 #10-16 X 3/8 PL-FH-SMS 18-8 UC USED W/ 9733 & 9734 TRANSOM ADAPTOR TRANSOM GLZ. JAM ADAP FAST. SYSTEM II ADAPTOR W104 WEATHERING WINDOW SIZE FORMULA: D.L.O. - 5/8" Wall SFP6 #8-15 X 1/2 PL-TH-SMS 18-8 A USED W/ 9673 & 9674 TRANSOM ADAPTOR SFP5 #8-15 X 3/4 PL-FH-SMS 18-8 A WINDOW ADAP. SCREW USED W/ 9648 A 12/2001

20 STEP 2) NOTE: Allow extra clearances, if necessary, to accommodate building tolerances. Cut the verticals and vertical face caps to the frame size. NOTE: Verticals must run through. If the opening has an entrance, see the appropriate frame and door fabrication and installation sheets. PAGE 18 SECTION III - SCREW SPLINE FARICATION NOTE: STEP 1) The screw spline system is a fabrication and erection method that permits the preassembly of single units in the shop or at the job site. These units are then erected by mating the male mullion with the female mullion counterparts. When an entrance is required, shear block joinery must be used to attach the side lite horizontals to the immediate door frame. The other side of the side lite will be fabricated for screw spline joinery as usual. DUE TO THE SCREW TENSIONS REQUIRED FOR CORRECT INSTALLATION, IT WILL E NECESSARY TO WAX THE FRAME ASSEMLY SCREWS TO PREVENT GALLING AND REAKAGE. Measure the opening to determine the cut length of the frame components. NOTE: Allow a minimum 1/2" shim and caulk space around the perimeter. NOTE: Door jambs run to the floor and are cut longer than other verticals. STEP 3) STEP 4) Drill holes for the assembly screws on the vertical members. See the drilling template on page 19 or the drill jig guide on page 20. Cut the horizontal members to the day lite openings (between the vertical mullions). Cut the horizontal face caps to day lite openings minus 1/16". (D.L.O. - 1/16") MDM 04/2008

21 VERTICAL DRILLING- HORIZONTAL DRILLING-.980 = SCREW SPLINE # 16 DRILL (.177 DIA.) = SHEAR LOCK # 21 DRILL (.159 DIA.) = SHEAR LOCK (.187 DIA.).250 PAGE 19 SECTION III - SCREW SPLINE FARICATION SET EDGE OF TEMPLATE FLUSH WITH GLAZING SIDE (VERT.) 960 WALL [EXTERIOR] DRILLING TEMPLATE /8" NOTCH TO CLEAR SHEAR LOCK AT THE 2 9/16" SYSTEM [INTERIOR] CONT FIG. # 1 3/8" NOTCH TO CLEAR SHEAR LOCK AT THE 2 9/16" SYSTEM. KDE 16/2003

22 TOP OF VERTICAL CD PAGE 20 SECTION III - SCREW SPLINE FARICATION CONT. DRILL JIG CD CD CD OTTOM OF HEAD CD TOP OF INT. HORIZONTAL CD CD CD OT. OF INT. HORIZONTAL CD TOP OF SILL CD CD H457 CD OTTOM OF VERTICAL.177" DIA. (#16) DRILL A = 1-9/16" ACK MEMER = 2-9/16" ACK MEMER C = 4-1/16" ACK MEMER D = 4-13/16" ACK MEMER A,,C, or D = SCREW SPLINE USE THESE HOLES FOR SCREW SPLINE ATTACHMENT FIG. # 2

23 PAGE 21 SECTION III - SCREW SPLINE FARICATION (CONT.) 9625/9626 = 2 9/16".M. 9611/9612 = 4 1/16".M. 9614/9615 = 4 13/16".M C A F A E X D Top portion of the drilling template See page 19 & 20. OTTOM OF HEADER FIG. # For 2 9/16" back member - top screw spline holes drill the marked "D" & "E" locations dia.(# 16 Drill) (2 Holes) For 4 1/16" & 4 13/16" back members - top screw spline holes drill the marked "D" & "F" locations dia. (# 16 Drill) (2 Holes)

24 PAGE 22 SECTION III - SCREW SPLINE FARICATION For 2 9/16" back member - intermediate screw spline holes drill the marked "D" & "E" locations dia.(# 16 Drill) (2 Holes) For 4 1/16" & 4 13/16" back members - intermediate screw spline holes drill the marked "D" & "F" locations dia.(# 16 Drill) (4 Holes) 9625/9626 = 2 9/16".M. 9611/9612 = 4 1/16".M. 9614/9615 = 4 13/16".M. (CONT.) F E C D F A A E D TOP OF INTERMEDIATE FIG. # 4 OTTOM OF INTERMEDIATE Middle portion of the drilling template See page 19 & 20.

25 PAGE 23 SECTION III - SCREW SPLINE FARICATION (CONT.) 9625/9626 = 2 9/16".M. 9611/9612 = 4 1/16".M. 9614/9615 = 4 13/16".M. For 2 9/16" back member - sill screw spline holes drill the marked "D" & "E" locations dia.(# 16 Drill) (2 Holes) For 4 1/16" & 4 13/16" back members - sill screw spline holes drill the marked "D" & "F" locations dia.(# 16 Drill) (2 Holes) F E C D A A TOP OF SILL FIG. # ottom portion of the drilling template See page 19 & 20.

26 9628 PAGE 24 SECTION III - SCREW SPLINE FARICATION (CONT.) 9613 Apply butyl type sealant 9616 at metal to metal joints of horizontal and vertical members. Refer to page 26. FEMALE HALF OF SPLIT MULLION S / / / S108 FIG. # 6 STEP 5) STEP 6) S108 Apply butyl type sealant to the ends of all horizontals before assembling the units. See Fig. # 8 thru Fig. # 11 on page 26. Assemble the units as shown in Fig. # 6 above and in Fig. # 7 on page 25. JDA 1/2001

27 PAGE 25 SECTION III - SCREW SPLINE FARICATION MALE HALF OF SPLIT MULLION (CONT.) NOTE: 1 9/16" ACK MEMER SYSTEM CANNOT E SCREW SPLINE ASSEMLED / / / S108 Apply butyl type sealant at metal to metal joints of horizontal and vertical members. Refer to page 26. S108 FIG. # 7 STEP 7) Snap together the assembled female and male units, then install into the opening. S108

28 PAGE 26 SECTION III - SCREW SPLINE FARICATION (CONT.) FIG. # 8 FIG. # 9 FIG. #6 THRU # 9 SHOW THE SHADED AREAS WHERE A UTYL TYPE SEALANT MUST E APPLIED TO THE ENDS OF THE HORIZONTALS, AT METAL TO METAL JOINTS. FIG. # 10 # 9667 ADAPTOR - 1/4" GLZ. # 9666 ADAPTOR - 1/2" GLZ. FIG. # 11 Adaptors are available to convert 1" glazing systems to 1/4" and 1/2" glazing. Refer to Fig. # 10 and # 11 above.

29 PAGE 27 SECTION IV - SHEAR LOCK FARICATION STEP 1) Measure the opening to determine the cut length of the frame components. NOTE: Allow a minimum 1/2" shim and caulk space around the perimeter. NOTE: Allow extra clearances, if necessary, to accommodate building tolerances. STEP 2) Cut the verticals and vertical face caps to the frame size. NOTE: Verticals must run through. If the opening has an entrance, see the appropriate frame and door fabrication and installation sheets. NOTE: Door jambs run to the floor and are cut longer than other verticals. STEP 3) STEP 4) STEP 5) Drill mounting holes for the shear blocks on the vertical members. See the drilling template on page 28 or the drill jig guide on page 29. Also refer to pages 30 through 32 for drilling information. Cut the horizontal members to the daylite openings (between the vertical mullions). Cut the horizontal face caps to daylite openings minus 1/16". (D.L.O. - 1/16") Drill the holes in the horizontals for attachment to the shear blocks. Refer to Fig. # 14 and # 15 on page 33. MDM 04/2008

30 VERTICAL DRILLING- HORIZONTAL DRILLING-.980 = SCREW SPLINE # 16 DRILL (.177 DIA.) = SHEAR LOCK # 21 DRILL (.159 DIA.) = SHEAR LOCK (.187 DIA.).250 PAGE 28 SECTION IV - SHEAR LOCK FARICATION SET EDGE OF TEMPLATE FLUSH WITH GLAZING SIDE (VERT.) [EXTERIOR] 960 WALL DRILLING TEMPLATE /8" NOTCH TO CLEAR SHEAR LOCK AT THE 2 9/16" SYSTEM [INTERIOR].150 CONT FIG. # 12 3/8" NOTCH TO CLEAR SHEAR LOCK AT THE 2 9/16" SYSTEM. KDE 16/2003

31 TOP OF VERTICAL CD PAGE 29 SECTION IV - SHEAR LOCK FARICATION CONT. DRILL JIG CD CD CD OTTOM OF HEAD CD TOP OF INT. HORIZONTAL CD CD CD OT. OF INT. HORIZONTAL CD TOP OF SILL CD CD CD OTTOM OF VERTICAL H " DIA. (#21) DRILL A = 1-9/16" ACK MEMER = 2-9/16" ACK MEMER C = 4-1/16" ACK MEMER D = 4-13/16" ACK MEMER A,,C, or D = SHEAR LOCK USE THESE HOLES FOR SHEAR LOCK ATTACHMENT FIG. # 13

32 PAGE 30 SECTION IV - SHEAR LOCK FARICATION (CONT.) C A F A E X D Top portion of the drilling template. See page 28 and 29. OTTOM OF HEADER FIG. # For 1 9/16" back member - top shear block holes drill the marked "A" locations.159 dia. (# 21 Drill) (2 places). For 2 9/16" back member - top shear block holes drill the marked "A" & "" locations.159 dia. (# 21 Drill) (3 places). For 4 1/16" & 4 13/16" back members - top shear block holes drill the marked "A" & "C" locations.159 dia. (# 21 Drill) (3 places).

33 PAGE 31 SECTION IV - SHEAR LOCK FARICATION (CONT.) For 1 9/16" back member - intermediate shear block holes drill the marked "A" locations.159 dia. (# 21 Drill) (2 places). For 4 1/16" & 4 13/16" back members - intermediate shear block holes drill the marked "A" & "C" locations.159 dia. (# 21 Drill) (3 places). For 2 9/16" back member - intermediate shear block holes drill the marked "A" & "" locations.159 dia. (# 21 Drill) (3 places). F E TOP OF D INTERMEDIATE A A D E C F Middle portion of the drilling template. See page 28 and 29. OTTOM OF INTERMEDIATE FIG. # 15

34 SECTION IV - SHEAR LOCK FARICATION (CONT.) PAGE 32 For 1 9/16" back member - bottom shear block holes drill the marked "A" locations.159 dia. (# 21 Drill) (2 places). For 2 9/16" back member - bottom shear block holes drill the marked "A" & "" locations.159 dia. (# 21 Drill) (3 places). For 4 1/16" & 4 13/16" back members - bottom shear block holes drill the marked "A" & "C" locations.159 dia. (# 21 Drill) (3 places). F E C D A TOP OF SILL A ottom portion of the drilling template. See page 28 and FIG. # 16

35 (CONT.) PAGE 33 SECTION IV - SHEAR LOCK FARICATION STT7 #10 x 1" P.H.S.M.S. FIG. # 19 NOTE: All shear blocks are predrilled at the factory. (# K147)(# K150)(# K170) Showing head application DRILL utt this edge of the fixture against the glazing dart. FIG. # 18 Showing sill application. Line up the edge of the fixture with the end of the horizontal. "X" Drill hole "X".187 dia. (# 13 Drill) to clear for the horizontal attachment screw. FIG. # 17

36 (CONT.) PAGE 34 SECTION IV - SHEAR LOCK FARICATION SEALANT ON ENDS SEE PAGE FIG. # 20 SEALANT ON ENDS SEE PAGE 26 K150 K170 K147 STEP 6) Apply a butyl type sealant to the ends of all horizontals before assembling the units as shown in Fig. #20 above. See page 26 for sealant application guidance. STEP 7) Assemble the units as shown in Fig. # 20 above.

37 SECTION V A - SCREW SPLINE / SHEAR LOCK FARICATION SNAP ON COVERS AND WEEP HOLES PAGE 35 The vertical covers are installed first. The length is the same as the frame size. The weep holes are located in the underside and at the ends of the intermediate horizontal cover, 1" from the end and 1/4" in diameter. See Fig. # 21 and # 22 below. FRAME SIZE 1" HORIZONTAL COVER LENGTH = D.L.O. - 1/16" 1" 1/4" FIG. # 21 VERTICAL COVER LENGTH = FRAME SIZE HORIZONTAL COVER The horizontal covers are installed after the vertical covers. The cut length is D.L.O. - 1/16". 1/4" 1/4" DIA. WEEP FIG. # 22

38 SECTION V A - PRIMARY SEAL SCREW SPLINE / SHEAR LOCK FARICATION SNAP ON COVERS AND WEEP HOLES CONT. PAGE 36 A COSMETIC CAULK JOINT CAN E ADDED TO THE HEAD AND JAM COVERS AFTER THE UNIT IS GLAZED. A PRIMARY SEAL WILL STILL E REQUIRED AS INDICATED IN FIG. # 23. WEEP DO NOT SEAL FRONT EDGE LEAVE OPEN FOR DRAINAGE WEEP HOLES ARE HIDDEN PRIMARY SEAL FIG. # 23

39 SECTION V - SCREW SPLINE / SHEAR LOCK FARICATION CONT. PAGE 37 GLASS SETTING CHAIR AND GLAZING ADAPTORS Use setting block # K149 when using 1/4" and 1/2" glazing adaptors (# 9667 or # 9666) in a 1" glazed system. 4 1/2" FIG. # 24 The glazing adaptor will need to be notched to clear the setting chair/block at quarter point locations, as shown in Fig. # 24 and # 25. C L REMOVE LC CENTER LINE OF CUTOUT AT QUARTER POINTS #9666 OR # /2" FIG. # 25 FULL SIZE

40 SECTION V C - SCREW SPLINE / SHEAR LOCK FARICATION CONT. PAGE 38 SYSTEM II ADAPTOR FOR P.O. / P.I. & CASEMENTS The vertical SYSTEM II adaptor runs through and is square cut. The cut length formula is frame D.L.O. - 1/6". The horizontal adaptor requires notching to match the vertical. The cut length formula for the horizontal adaptor is frame D.L.O. - 7/16", then notch the vertical leg back 9/16" x 1/8" at each end. These dimensions allow 1/32" clearance per end. Install the weathering in each piece and attach the adaptors with #SFP5 screws, 3" from the ends and 12" on center. Seal the ends with a nonhardening sealant completely. Then install the System II window tight against the weathering leg of the adaptor. Use appropriate blocking and fasteners as required. INTERIOR VIEW #9648 VERTICAL IS SQUARE CUT HORIZONTAL IS END NOTCHED /32" CLEARANCE /32" CLEARANCE TOP VIEW.125 FIG. # 26 1/32" CLEARANCE.570 1/2 SIZE

41 PAGE 39 SECTION VI - DOOR FRAME INSTALLATION NOTE: If an entrance frame is required, it must be installed first. NOTE: If NO entrance frame is required, proceed to Section VII. WEEP THE TRANSOM AR WITH (2) 1/4" DIA. HOLES, 5/8" DOWN FROM THE TOP AND AT 1/4 POINTS..625 JAM END #9633 SHOWN, OTHERS SIMILAR. STEP 1) STEP 2) STEP 3) 1/4 POINT 1/4" DIA. FIG. # 27 Correctly locate the entrance frame in the opening. Set the assembled door frame in the opening, plumb and level. Anchor the door frame as indicated below in Fig. # 27A. Also see Fig. # 28 thru Fig. # 30 on page 40. NOTE: The door jambs run to the floor and are cut longer than other verticals. K-124/K-125 Threshold clip & screws This continuous bead of sealant runs from jamb to opposite jamb, under the threshold and to the condition or it ties into the perimeter seal under the side lite sill flashing. K-153/K-154 Threshold clip & screws Conc. rod panic 960 Wall THRESHOLD (9950 Typ.) FIG. # 27A JDA 3/2002

42 PAGE 40 SECTION VI - DOOR FRAME INSTALLATION (CONT.) SEE PAGES 10 THRU PAGE 12 FOR DOOR HEADER AND DOOR JAM IDENTIFICATION. W /9155 FIG. # 28 Anchor through the header glazing pocket with flat head screws. The fastener will be concealed by the closed door. Locate the fastener 6" from the ends and 24" on center maximum spacing. Attach through the threshold with flat head screws. INTERIOR FIG. # 29 Apply a continuous bead of sealant from door jamb to door jamb. Install the door stop after the jambs are plumb and anchored. 9154/9155 W138 FIG. # 30 Anchor through the glazing pocket at the jambs with flat head screws. The fastener will be concealed by the closed door. SEE THE DOOR SHIPPING CARTON FOR DOOR INSTALLATION INSTRUCTIONS.

43 SECTION VI - DOOR FRAME INSTALLATION TRANSOM LITE GLAZING ADAPTOR CUT LENGTH FORMULA FOR TRANSOM APPLIED GLAZING = D.L.O. - 1/16" PAGE 41 (CONT.) APPLY A CONTINUOUS EAD OF SEALANT VERTICALLY TO SET THE ADAPTOR INTO SFP6 W115 W FIG. # 31 11/16" D.L.O. 1/2" GLASS ITE APPLY SEALANT AS SHOWN AT HEAD AND TRANSOM AR AND 1" EACH WAY IN THE GLAZING UL TRACK PERIMETER MEMER AT HEAD CONDITION SHEAR LOCK ATTACHED TYPICAL JAM MEMER FIG. # 32 IT IS NOT REQUIRED TO REMOVE THE EXTRUDED DOOR STOP IN THE TRANSOM AREA TO APPLY THE TRANSOM GLAZING ADAPTOR. THE ADAPTOR WILL APPLY OVER THE FIN STOP. THE FIN STOP WILL HAVE TO E NOTCHED AT THE TRANSOM AR.

44 SECTION VII - SILL FLASHING INSTALLATION STEP 1) Install the sill flashing continuously between the masonry jambs or door frame to masonry. Refer to Fig. # 33 & # 34 below. PAGE 42 Seal the ends of the sill flashing with a "skinning", nonhardening type of sealant (i.e., silicone). efore the fastener is inserted, force sealant into the hole for the sill perimeter fastener to ensure that the hole through the sill flashing is sealed. Cover the heads of all attachment screws with sealant. FIG. # 33 Shim the sill flashing until it is level and set it in a continuous bead of sealant. STEP 2) FIG. # /16" TRIMMED /4" TRIMMED /16" TRIMMED Anchor the sill flashing 24" O.C. and cover the heads of all attachment screws with sealant. Splice the sill flashing every 20-0" as shown in Fig. # 35 below. F-542 splice sleeve is supplied for use with the 4 13/16" back member. Trim F-542 to the correct length for the particular system depth being used. If the elevation s configuration consists of verticals through, for best performance, locate the sill flashing splice 6" from vertical intermediates. SILL FLASHING NUMER & LENGTH /16" AS SUPPLIED Fill the vertical glazing pocket with sealant to divert water onto the sill flashing. SEE CHART 6" MINIMUM ond breaker tape 1" wide centered on splice. 1 1/2".050 aluminum formed sleeve Set the sill flashing splice in a bed of sealant around the perimeter of the splice. 3/8" FIG. # 35 Use backer rod and silicone to fill the joint. F960 WALL JDA 6/2002

45 PAGE 43 SECTION VII - SILL FLASHING INSTALLATION (cont.) Cover the heads of all attachment screws with sealant. The flashing attachment screws are located in the opening of the back member. SEALANT When corners are required, miter the flashing to the required angle and install as shown in Fig. # 36 and # 37. SILL FLASHINGS AVAILALE: /16".M /16".M /16".M /16".M. 3" TYP. FIG. # 36 Cover the heads of all attachment screws with sealant. The flashing attachment screws are located in the opening of the back member efore the fastener is inserted, force sealant into the hole for the sill perimeter fastener to ensure that the hole through the sill flashing is sealed. 3" TYP. SEALANT FIG. # WALL JDA 6/2002

46 SECTION VII - SILL FLASHING INSTALLATION END CAP ATTACHMENT VIEW AT JAM AND CONDITION PAGE 44 (CONT.) TYPICAL VERTICAL INTERMEDIATE TYPICAL PERIMETER MEMER TYPICAL SILL MEMER The sill flashing must be sealed to the condition and the jamb member set in a bead of sealant to ensure a water tight seal. Fig. # 38 SEALANT SEALANT REFER TO PAGE 13 FOR THE CORRECT END CAP to ACK MEMER COMINATION Incorporating the sill flashing end caps will complement the sealing procedure. The end caps must be sealed to the condition and the sealant must tie in with the jamb blocking and the perimeter seals. The end cap edges must also be concealed with the sealant to present a neat and clean installation. This may cause the caulk joint at the jamb to increase in thickness, if the condition is irregular.

47 SECTION VIII A - FRAME ANCHORING AND SEALING SEAL THE PERIMETER HEAD AND JAMS AT OTH THE INTERIOR AND THE EXTERIOR. SCREW SPLINE / SHEAR LOCK INSTALLATION PAGE 45 Seal horizontal cavities that are accessible with a silicone type sealant (D.C.795). Shim and anchor the perimeter 6" from the ends and 24" on center. KEEP THIS GLAZING LEG FACE FREE FROM ANY TYPE OF SEALANT. SEAL ALL JAM CAVITIES WITH A SILICONE TYPE SEALANT. FIG. # 40 KEEP THIS GLAZING LEG FACE FREE FROM ANY TYPE OF SEALANT. FIG. # 39 Apply sealant to the upturned leg before setting the unit in place. SEALANT 960 WALL To allow for moisture migration to the exterior, do not seal this front seam. efore the fastener is inserted, force sealant into the hole for the sill perimeter fastener to ensure that the hole through the sill flashing is sealed. Cover the heads of all fasteners with sealant as shown. JDA 6/2002

48 SECTION VIII - STEP 1) SCREW SPLINE / SHEAR LOCK INSTALLATION GLASS SETTING CHAIR ASSEMLY INSTALLATION The glass setting chair/block can be installed by rotating upward and in, then push down to lock in place. See Fig. # 41 below. DOWN TO LOCK PAGE 46 UPWARD AND IN STEP 2) FIG. # 41 To insure proper installation of the setting chair/block, press down until locked into position. See Fig. # 42 below. LOCKING POINT The setting chair is parallel to the horizontal surface when installed correctly. FIG. # 42

49 SECTION VIII C - SCREW SPLINE / SHEAR LOCK INSTALLATION PAGE 47 STEP 3) INSTALLATION OF WATER DEFLECTOR AND With the exception of the head and sill, all intermediate horizontals must include a continuous water deflector to divert any water to the verticals or to the weep holes. See Fig. # 46 on page 48 for the deflector end notching. PRESS DOWN SPREADING LEGS 2nd. SETTING CHAIR / LOCK [1" Glazing] 3rd. THEN ROTATE IN TYP. INTERMEDIATE HORIZONTAL MEMER 1st. Hook the "V" over the edge of the gasket race and spread the legs slightly. L126 WATER DEFLECTOR FIG. # 43 STEP 4) A silicone type sealant should be applied after the continuous water deflector is installed. Apply a continuous bead of silicone type sealant (D.C.795). L126 WATER DEFLECTOR FIG. # 44 TYP. INTERMEDIATE HORIZONTAL MEMER

50 SECTION VIII C - SCREW SPLINE / SHEAR LOCK INSTALLATION INSTALLATION OF WATER DEFLECTOR AND SETTING CHAIR / LOCK [1" Glazing] CONT. PAGE 48 WATER DEFLECTOR NOTCH EACH END OF WATER DEFLECTOR SETTING CHAIR/LOCK SETTING LOCKS SHOULD E LOCATED AT QUARTER POINTS ACK NOTCH EACH END OF WATER DEFLECTOR.625 LENGTH OF WATER DEFLECTOR EQUALS D.L.O. PLUS 1 1/4". FIG. # 45 FRONT.625 FIG. # 46

51 SECTION VIII D - SCREW SPLINE / SHEAR LOCK INSTALLATION PAGE 49 DETAILS SHOWING TYPICAL GLAZING CONDITIONS AND THE RELATIONSHIP OF PARTS TO EACH OTHER. 1/4" GLAZING W115 K148 H261 L130 FIG. # 47 1" GLAZING W115 K149 H260 L126 FIG. # 48

52 SECTION VIII E - SCREW SPLINE / SHEAR LOCK INSTALLATION STEP 1) 1/4" AND 1/2" GLAZING ADAPTORS w/ L129 WATER DEFLECTOR Screw attach the glazing adaptor to the back mullion using the SPP8 screw, 3" from the end and 12" on center. Refer to Fig. # 49 below. PAGE 50 SPP /2" GLASS /4" GLASS FIG. # 49 STEP 2) Set the water deflector s heel end first, then snap the outer leg onto the leg of the adaptor. Refer to Fig. # 50 below. SPP FIG. # 50

53 SECTION VIII E - SCREW SPLINE / SHEAR LOCK STEP 3) INSTALLATION 1/4" AND 1/2" GLAZING ADAPTORS w/ L129 WATER DEFLECTOR Apply a bead of sealant across the length of the deflector, and across the bulb gasket, and the end of the deflector at the vertical member s pocket. Refer to Fig. # 51 below and to Fig. #53 on page 52. PAGE 51 CONT. CONTINUOUS EAD OF SEALANT L129 L129 SPP8 STEP 4) 9666 FOR 1/2" GLASS FIG. # FOR 1/4" GLASS The clips H260 or H261 should be installed as soon as possible before the sealant from step # 3 can setup. Care should be taken to not disengage the water deflector when setting the glass unit below. NOTE AT HORIZONTAL INTERMEDIATES ONLY: The clips H260 or H261 need to be installed with the ear up as shown to accommodate setting the lower glass unit. EAR SPP8 FIG. # 52 L FOR 1/4" GLASS

54 SECTION VIII E - SCREW SPLINE / SHEAR LOCK INSTALLATION OF WATER DEFLECTOR, 1/4" AND 1/2" GLAZING ADAPTORS PAGE 52 CONT. NOTCH EACH END OF THE WATER DEFLECTOR. FILL THE VOID ETWEEN THE WATER DEFLECTOR AND THE "DART" WITH SILICONE AND EXTEND INTO THE VERTICAL GLAZING POCKET ACROSS THE GLAZING UL FILLING THE GAP. 1" GLASS GLAZED OVER 1/4" OR 1/2" GLASS OR SPANDREL WATER DEFLECTOR OVER ADAPTOR SEALANT SETTING CHAIR / LOCK SETTING LOCKS SHOULD E LOCATED AT QUARTER POINTS INTERIOR 9667 SHOWN 9666 OPT..375 EXTERIOR NOTCH EACH END OF WATER DEFLECTOR AS SHOWN. LENGTH OF WATER DEFLECTOR EQUALS D.L.O. PLUS 1 1/4". FIG. # 54 FIG. # 53

55 SECTION VIII F - SCREW SPLINE / SHEAR LOCK INSTALLATION PAGE 53 DETAILS SHOWING THE RELATIONSHIP OF THE GLAZING ADAPTORS AND OTHER PARTS AT HORIZONTAL INTERMEDIATES /4" GLAZING ADAPTOR 1/4" ADAPTOR (FOR 1" GLAZED SYSTEM) L129 H260 SPP /4" GLAZING ADAPTOR SET IN SEALANT FIG. # 55 Elevations without horizontal intermediates may use #9649 1/4" glazing adaptor throughout as an alternate to the #9667 adaptor. The glazing adaptors with a water deflector locating leg must be used with a horizontal intermediate. See page 52 for the notching of # 9667 and # 9666 glazing adaptors for setting chair clearance /2" GLAZING ADAPTOR 1/2" ADAPTOR (FOR 1" GLAZED SYSTEM) L129 H260 SPP /2" GLAZING ADAPTOR SET IN SEALANT FIG. # 56

56 SECTION VIII F - SCREW SPLINE / SHEAR LOCK INSTALLATION CONT. PAGE 54 DETAILS SHOWING THE RELATIONSHIP OF THE GLAZING ADAPTORS AND OTHER PARTS AT THE SILL /4" ADAPTOR 1/4" ADAPTOR (FOR 1" GLAZED SYSTEM) H260 SPP8 FIG. # 57 See page 52 for the notching of # 9667 and # 9666 glazing adaptors for setting chair clearance /2" ADAPTOR 1/2" ADAPTOR (FOR 1" GLAZED SYSTEM) H260 SPP8 FIG. # 58

57 SECTION VIII G - SCREW SPLINE / SHEAR LOCK STEP 1) UL GASKET INSTALLATION Push in all VERTICAL glazing gasket, being careful not to stretch the gasket. Apply sealant in the glazing bulb cavity 1" from the ends, and push the bulb gasket into the sealant. Refer to the figures below. PAGE 55 GASKET SHOWN INSTALLED Push the bulb in being careful not to strech the gasket. Set bulb in sealant 1" from the ends of all horizontals and verticals. FIG. # 58 1" TYP. SILICONE TYPE SEALANT (D.C. 795) FIG. # 60 STEP 1) Push in all HORIZONTAL glazing gasket, being careful not to stretch the gasket. Apply sealant in the glazing bulb cavity 1" from the ends, and push the bulb gasket into the sealant. Refer to the figures above.

58 SECTION VIII H - SCREW SPLINE / SHEAR LOCK INSTALLATION SYSTEM II WINDOW ADAPTOR FOR PROJECT OUT, PROJECT IN, AND CASEMENTS PAGE 56 SEAL INTERSECTION COMPLETELY INSTALL W104 WEATHERING FIG. # 61 INSTALL W104 WEATHERING (FOR 1" GLAZED F960 SYSTEMS ONLY) VERTICALS RUN THROUGH, COPE HORIZONTALS TO MATCH. SYSTEM II WINDOWS SYSTEM II WINDOW SIZE FORMULA D.L.O. - 5/8" 9648 W104 GASKET 9/16" 3/4" 3/16" H260 FIG. # 62

59 SECTION IX - STRUCTURAL SILICONE GLAZED MULLION PAGE 57 STEP 1) Cut the S.S.G. mullion to frame D.L.O. and screw spline attach the mullion to the perimeter members using the S108 screw spline screws. See page 59. Set the assembled unit in place on the sill flashing, and anchor as directed previously. Refer to Section VIII. STEP 2) Install the butt glaze spacer tape to the butt glaze mullion as shown in Fig. #63 on page 58. The spacer tape will run the full length of the vertical butt glaze mullion. Peel back ONLY 2" of the exterior film of the spacer tape at the head or the sill. DO NOT remove all of the exterior film until the glass unit is installed and positioned correctly. STEP 3) STEP 4) Install the setting chairs at 1/4 points in the sill members. Set the glass units in place and install (2) glazing clips side by side 3" from the vertical mullion and a single clip at 9" on center from the pair, at the head and sill. e sure the ears of the clips are toward the glass unit at the head and sill, and jambs. Also, it must be facing up at the horizontal intermediates. Refer to page 61. Set the glass unit and position it with the correct glass bite all around. NOTE: Review the temporary glazing procedure presented on page 62, and apply these steps accordingly, if required. If incorporating this procedure, set the temporary glazing covers, leaving access to the vertical glass edges for the application of the structural silicone at the vertical butt glaze mullion. STEP 5) Peel off the exterior film of the butt glaze spacer tape and press the glass onto the spacer tape. Install the 12" temporary cover pieces at the head and sill to hold the glass units while the interior silicone is applied. Refer to page 59. STEP 6) Repeat the previous steps at other butt glaze mullions in the elevation. JDA 3/2001

60 SECTION IX - STRUCTURAL SILICONE GLAZED MULLION PAGE 58 CONT. STEP 7) STEP 8) STEP 9) Install the interior structural silicone to the glass/spacer tape/mullion, as shown below. This step will require an overnight cure. The next day remove the temporary covers and replace any clips that are broken in this process. Install the exterior structural silicone to the glass joint. Clean any excess sealant from the glass surface, presenting a clean professional appearance. This step will also require an overnight cure for the silicone. STEP 10) Install the W115 bulb gasket in the full length covers, allowing approximately 2% extra per length, to minimize gasket shrinkage. Install the full length covers at the head, sill, and jambs GAP FOR STRUCTURAL SILICONE WM11 SPACER TAPE Fig. # 63 GLASS UNIT GLASS UNIT GAP FOR STRUCTURAL SILICONE H260 CLIP - 1" GLAZING H261 CLIP - 1/4" GLAZING 9635 WM11 2 9/16".M. STRUCTURAL SILICONE Fig. # 64 5/8" ITE 1/2" 5/8" ITE A 7/2001

61 SECTION IX - STRUCTURAL SILICONE GLAZED MULLION CONT. PAGE 59 ASSEMLY PROCEDURE FOR STRUCTURAL SILICONE GLAZED VERTICAL MULLIONS S108 SCREWS TYP. SYSTEM HEAD MEMER H260 CLIP - 1" GLAZING H261 CLIP - 1/4" GLAZING C L 6" TYP. SINGLE CLIP C L 3" DUAL CLIP 3" DUAL CLIP C L 6" TYP. SINGLE CLIP C L # /16".M. # /16".M. # /16".M. CUT TO FRAME D.L.O. TYP. SYSTEM SILL MEMER MAINTAIN CLEARANCE ETWEEN THE COVER SECTIONS TO APPLY THE STRUCTURAL SILICONE SEAL AT THE EXTERIOR AFTER THE INTERIOR SEAL HAS CURED. Fig. # 65 TYPICAL SYSTEM EXTERIOR COVER CLIPS & COVERS NOT SHOWN AT THE HEAD FOR CLARITY. JDA 3/2001

62 SECTION IX - STRUCTURAL SILICONE GLAZED MULLION CONT. PAGE 60 INSTALLATION OF THE WATER DEFLECTOR AT A S.S.G. MULLION THE WATER DEFLECTOR RUNS THROUGH AT THE MULLION. SEE PAGE 48 FOR END NOTCH AT JAMS AND VERTICAL INTER. #9635 SHOWN, #9662 & #9663 SIMILAR. SEE PAGE 47 FOR SEALING THE WATER DEFLECTOR TO THE DART OF THE MULLION. Notch the water deflector as shown below, and seal completely from horizontal to horizontal. NOTE: C L IF A SPLICE JOINT IS REQUIRED LOCATE IT 6" AWAY FROM THE S.S.G. MULLION AND SEAL THE ENDS COMPLETELY. SETTING CHAIR/LOCK SETTING LOCKS SHOULD E LOCATED AT QUARTER POINTS FIG. # C L ACK TRIM THIS SECTION L126 SHOWN, OTHERS SIMILAR. FIG. # 67 FRONT 960 WALL JDA 3/2002

63 SECTION X A - GLAZING GLASS SIZE / GLASS SETTING PAGE 61 Glass size = D.L.O. + 1" for both 1" glazing and 1/4" glazing systems. (See page 59 for butt glaze mullion glass bite requirements.) 9" TYP. TO SINGLE CLIP LC DUAL CLIP e sure the "ears" of the clips face toward the glass at the head, jamb, and sill. Also, up at the horizontal intermediates. 3" 3" CL DUAL CLIP 9" TYP. TO SINGLE CLIP FIG. # 68 STEP 1) NOTE: 960 WALL The glass must be installed prior to the installation of the remaining isolator clips. After the glass is installed and properly positioned in the opening, locate and install the isolator clips as shown in figure # 68 above. The isolator clips are located: side by side pairs, 3" from each vertical or horizontal intersection and single clips 9" on center. The isolator clips alone are not suitable for temporary glazing. At no time should set glass or panels be left unattended with only the isolator clips holding the units in place. Prompt installation of the snap covers is required to obtain the full structural capability of the system. If temporary glazing is required, please refer to the Temporary Glazing instructions on pages 62 and 63. AH 11/2004

64 SECTION X - TEMPORARY GLAZING USING CLIPS & COVERS PAGE 62 D.L.O. D.L.O. D.L.O. D.L.O. TYP. APPLICATION SHOWING TEMPORARY COVER LOCATIONS 12" 6" TYP. TO SINGLE CLIP LC DUAL CLIP 3" (2) 12" COVERS w/ UL GASKET & (3) ISOLATOR CLIPS PER COVER HORIZONTALLY & VERTICALLY NOTE: 3" C L DUAL CLIP 9" TYP. TO SINGLE CLIP 12" FIG. # 69 If temporary glazing is required, EFCO recommends the use of (2) 12" lengths of the snap cover and (3) clips min. per cover piece, snapped in place as shown above, at the corners of the horizontals and verticals to retain the glass until the full length covers can be installed. This temporary clipping should be installed at every corner of each daylight opening resulting in 8 pieces of snap cover per daylight opening. This is a temporary application only and is not to be used for a structural application. This system will not meet structural performances until full length covers and the required quantity of clips have been installed. 960 WALL JDA 3/2002

65 SECTION X C - TEMPORARY GLAZING FOR STRUCTURAL UTT GLAZED SYSTEMS USING CLIPS AND COVERS S108 SCREWS PAGE 63 TYP. SYSTEM HEAD MEMER H260 CLIP - 1" GLAZING H261 CLIP - 1/4" GLAZING # /16".M. # /16".M. # /16".M. 12" Fig. # 70 LC 6" TYP. SINGLE CLIP CL 3" DUAL CLIP 3" DUAL CLIP C L 6" TYP. SINGLE CLIP LC CUT TO FRAME D.L.O. TYP. SYSTEM SILL MEMER 12" TYP. SYSTEM EXT. COVER CLIPS & COVERS NOT SHOWN AT THE HEAD FOR CLARITY, UT THEY MUST E USED. 960 WALL JDA 3/2002

Series 406 storefront. Installation Instructions

Series 406 storefront. Installation Instructions Series 406 storefront Installation Instructions Part NO. Y016 February 2013 Series 406 Installation Instructions TABLE OF CONTENTS Section I GENERAL NOTES Page 1 II PARTS IDENTIFICATION Page 2-3 III FABRICATION

More information

Series 955 Tech Set storefront. Installation Instructions

Series 955 Tech Set storefront. Installation Instructions Series 955 Tech Set storefront Installation Instructions Part NO. Y008 February 2013 TABLE OF CONTENTS SECTION PAGE I II III GENERAL NOTES AND GUIDELINES 1-2 PARTS IDENTIFICATION 3-5 DRILL JIGS 6-7 DRILL

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h ) SERIES 406X Installation Instructions Place photography here. Don t go over grey area (size 7.9961 w x 7.4561 h ) Table of Contents Section 1. General Notes and Guidelines. 2. Parts Identification Charts

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

Series Advanced and alternate. Installation Instructions

Series Advanced and alternate. Installation Instructions Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4

More information

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979)

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979) Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx 78934 Ph. (979) 732-2201 Fax (979) 732-2311 Westside Montessori School Building B Addition Environments, Inc Drymalla Construction February 14, 2013 Installation

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

Series 526 Thermal impact storefront. Installation Instructions

Series 526 Thermal impact storefront. Installation Instructions Series 526 Thermal impact storefront Installation Instructions Part NO. Y021 February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines. 3 II. Parts Identification Chart.......4-8 III.

More information

YES 40 FS/FI Storefront System Installation Manual

YES 40 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL DHS-500 IMPACT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS SECTION PAGE GENERAL NOTES 3 EXTRUSION & PARTS IDENTIFICATION 4-5 DETERMINE FRAME SIZE 6 FABRICATE VERTICAL MULLIONS & FILLERS 7-8 FABRICATE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

YWE 40 T Window Wall System Installation Manual

YWE 40 T Window Wall System Installation Manual Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

Series 525 impact storefront. Installation Instructions

Series 525 impact storefront. Installation Instructions Series 525 impact storefront Installation Instructions Part NO. Y020 February 2013 SECTION I GENERAL NOTES II PARTS IDENTIFICATION III FABRICATION A. DRILLING TEMPLATE (SCREW SPLINE VERTICALS) B. DRILLING

More information

YES 45 TU Thermal Storefront System Installation Manual

YES 45 TU Thermal Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION

More information

YSG 40/50/50T Window Wall System Installation Manual

YSG 40/50/50T Window Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the

More information

YES 45 FS/FI Storefront System Installation Manual

YES 45 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 900 SERIES RIBBON WINDOW INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 November 2016 www.tubeliteinc.com Page 1 TABLE OF CONTENTS GENERAL CONSTRUCTION NOTES...3-4

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC INSTALLATION EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC. 2004 175-970.01.04 PART NO. 175-970 INSTALLATION INSTRUCTIONS CONTENTS These

More information

Series Exterior glazed curtain wall. Installation Instructions

Series Exterior glazed curtain wall. Installation Instructions Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.

More information

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com S E R I E S 6 0 0 0 X T - S T O R E F R O N T I

More information

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO. FEBRUARY, 2012 1 INSTALLATION CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS 2 FEBRUARY, 2012 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION

More information

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3

More information

Part Y024 September 2015

Part Y024 September 2015 Part Y024 September 2015 EFCO 2015 Page 1 Section 1. General Notes and Guidelines... 2. Parts Identification Charts.. 3. Fabrication. A. Screw Spline Method. B. Shear Block Method - Verticals C. B Type

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address: Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information............................. Page 2 4 Outside Glaze Non Thermal...............................Page

More information

YSD 400 Sliding Door System Installation Manual

YSD 400 Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com FG-1000 & FG-2000 INSTALLATION & GLAZING INSTRUCTIONS These

More information

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE PATIO DOORS INSTALLATION GUIDE These instructions cover general installation conditions. Improper installation could affect your doors operation and warranty. Deviations from these instructions should

More information

Installation Instructions

Installation Instructions Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION

More information

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF ONTENTS General Information... p.2 Frame Fabrication...

More information

YHS 50 TU Storefront System & Model 35H Door Installation Manual

YHS 50 TU Storefront System & Model 35H Door Installation Manual Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 TU Framing Members... Page 1 YHS 50

More information

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass Captured System 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. B.G.

More information

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0292 HANDLING, STORAGE,

More information

Assembly and Installation Instructions Section 1

Assembly and Installation Instructions Section 1 Assembly and Installation Instructions Section 1 March 2013 PART NO. YS57 EFCO 2012 Page 2 Series 5500 XTherm Curtain Wall Assembly and Installation Instructions SECTION Note: Installation Instructions

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 400T SERIES CURTAIN WALL INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 October 2017 www.tubeliteinc.com Page 1 BLANK Page 2 www.tubeliteinc.com October 2017

More information

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 Framing Members... Page 1 YHS 50 Accessories...

More information

e-lite fabrication/assembly and Installation instructions

e-lite fabrication/assembly and Installation instructions e-lite fabrication/assembly and Installation instructions Part NO. YWLS February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines.. 3-4 II. E-Lite Stick Built Channel Base Assembly...

More information

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES I N S TA L L AT I O N I N S T R U C T I O N S BW3250 BLAST RESISTANT CURTAIN WALL Page 2 SERIES BW3250 BLAST WALL TABLE OF CONTENTS United States Aluminum PAGE GENERAL NOTES...2 and 3 FABRICATION...4 through

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors

More information

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

TCR 250 THERMAL COMPOSITE RIBBON WINDOW

TCR 250 THERMAL COMPOSITE RIBBON WINDOW CORRECT DRO OVER THE 5/8" 1" TOP OF HORIZONTAL 1 1/4" 2 3/8" SEAL THIS ACCESS HOLE ONLY 2 3/4".191 DIA. TAP HOLE FOR #14 SCREW DETAIL AT INCIDENTAL WATER APPLICATION STRAP ANCHOR DESIGNED ON A PER-JOB

More information

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System SERIES CF450 INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Non-Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System SERIES CF451T INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2 TRIM OFFICE PARTITIONS INSTALLATION INSTRUCTIONS SERIES 87 CENTER GLAZED WITH -/" TRIM OFFICE PARTITIONS Phone: (800) -6 Fax: (800) 58-7 crlaurence.com usalum.com crl-arch.com M056_Rev_D SERIES 87 OFFICE PARTITIONS CENTER GLAZED

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

SECTION C1 INSTALLATION INSTRUCTIONS

SECTION C1 INSTALLATION INSTRUCTIONS SECTION C1 SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM X 4 1 / for 1" GLAZING INSTALLATION INSTRUCTIONS EXTERIOR GLAZED Effective October 2014 www.cardcompro.com 1 INTERIOR

More information

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual YHC 300 IG Inside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly c CD $ a c Q / / Table of Contents Page Description 1 Parts list 2 3 4 5 6 Typical elevation & cut lengths General construction notes General installation notes Typical jamb assembly Typical intermediate

More information

Installation Instructions

Installation Instructions Installation Instructions 1293 N. Harvey Mitchell Pkwy. Bryan, Texas 77803 800.444.1444 ph 979.823.1005 fax www.aswcommercial.com Simplifying Windows Complete Architectural CD Binder Inside B l as t I

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation

More information

Sun Control-Solar Eclipse-Solar Shelf

Sun Control-Solar Eclipse-Solar Shelf Sun Control-Solar Eclipse-Solar Shelf Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS GENERAL INFORMATION Product Use...Page 3 Protection and Storage...Page

More information

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL Note: The installation details found in this package are generic and are for representation only with the intent of giving the installation team a

More information

Flashing Materials. Rough Opening Preparation

Flashing Materials. Rough Opening Preparation Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or

More information

CURTAIN WALL INSTALLATION AND GLAZING MANUAL

CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE tm - TC IG CURTAIN WALL INSTALLATION AND GLAZING MANUAL TABLE OF CONTENTS General Information...Page 3-5 Product Use... Page 3 Protection and Storage... Page 3 Check Material... Page 4 Field Conditions...

More information

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE Phone: (800) 421-6144 Fax: (800) 582-7501 crlaurence.com usalum.com crl-arch.com 11M0230 HANDLING, STORAGE, AND PROTECTION

More information

YOW 225 TU Window System

YOW 225 TU Window System ThermaBond Plus Poured & Debridged Technology YOW 225 TU SYSTEM DESCRIPTION YOW 225 TU PERFORMANCE FEATURES 2-1/4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Casement, Projected

More information

RELIANCE -LT INSTALLATION AND GLAZING MANUAL

RELIANCE -LT INSTALLATION AND GLAZING MANUAL RELIANCE -LT INSTALLATION AND GLAZING MANUAL NOTE: THE ASSEMBLY DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE ASSEMBLY TEAM A VISUAL REPRESENTATION

More information

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty. Prices DO NOT include glazing gaskets or weathering. See Accessories sheet. Exterior Glazed Back Members for 1" Glass Illustration Part Description Base List Weight/ Ft./ Box Price/S.L. S.L. S.L. Qty.

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

Installation Instructions

Installation Instructions Installation Instructions 400 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised September 2014 dependable@tubeliteinc.com Page 1 TABLE

More information

SERIES 3070-T MULTI-SLIDE ASSEMBLY & INSTALLATION INSTRUCTIONS

SERIES 3070-T MULTI-SLIDE ASSEMBLY & INSTALLATION INSTRUCTIONS Table of Contents I. Care and Maintenance...2 II. Tools / Material & Sealant Requirements...2 III. Assembly and Installation...2 IV. Glazing Assembly...3 V. Panel Assembly...3 1. X Panel...3 2. O Panel...4

More information

YSD 600 T/TH Sliding Door System Installation Manual

YSD 600 T/TH Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii & iii PARTS DESCRIPTION

More information

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System YSD 600 T/TH Sliding Door System Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii & iii PARTS DESCRIPTION Framing

More information

SIG Awning / Casement / Fixed Lite 100

SIG Awning / Casement / Fixed Lite 100 TYPICAL FRAME ASSEMBLY - AWNING WINDOW 07-01 85720-2 GASKET EXT FL JAMB 100 BS201 (3471) HEAD HINGED 100 86064 TRIM FIN A 83963 SCREW SQ 8G X 1.0 PAN PP SS #2 85737 GASKET EXT FL TRANSOM 85720-1 86065

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

SERIES 2100/2200 CURTAIN WALL

SERIES 2100/2200 CURTAIN WALL INSTALLATION INSTRUCTIONS SERIES 2100/2200 CURTAIN WALL Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0173 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

SECTION B INDEX STOREFRONT FRAMING SYSTEMS SECTION B INDEX STOREFRONT FRAMING SYSTEMS B PAGE DESCRIPTION 01 STOREFRONT FRAMING SPECIFICATIONS 02 175 SERIES 1 3/4" (44.5) X 4 1/2" (114.3) FLUSH GLAZE FRAMING FOR SINGLE GLAZING. 06 200 SERIES 2"

More information

SERIES 2100/2200 CURTAIN WALL

SERIES 2100/2200 CURTAIN WALL INSTALLATION INSTRUCTIONS SERIES 2100/2200 CURTAIN WALL Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0173 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

SERIES 8750XD UNITIZED CURTAIN WALL

SERIES 8750XD UNITIZED CURTAIN WALL SERIES 8750XD UNITIZED CURTAIN WALL Installation Instructions Sections 1-15 Jan 2015 PART NO. Y80B 1000 COUNTY ROAD MONETT, MO 65708 800.221.4169 EFCOCORP.COM Table Of Contents SECTION 1. General Notes

More information

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05 QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05 MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure: tempered glass and anodized aluminum. To assure a long lasting finish

More information

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS 162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. PERIMETER ANCHORING TO CALCULATE END REACTIONS MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) A IF THE END REACTION

More information

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8

More information

YVS 400 TU Window System

YVS 400 TU Window System YVS 400 TU SYSTEM DESCRIPTION YVS 400 TU PERFORMANCE FEATURES 4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Single Hung, Double Hung & Fixed Windows 1 /8 & 1 1 /16 Glazing

More information

Pocket Door Installation Instructions

Pocket Door Installation Instructions Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code

More information

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS Page 2-9: Installation Instructions, Figures 1, 2, & 3 Page 10-12: Figures A-1, A-2, & A-3: Installation

More information

YOW 350 XT Thermally Broken Operable Window System

YOW 350 XT Thermally Broken Operable Window System YOW 350 XT Thermally Broken Operable Window System MegaTherm Glass Fiber With 6/6 Nylon Thermal Break YOW 350 XT SYSTEM DESCRIPTION 3-1/2 Overall Frame Depth MegaTherm Thermal Break Construction: Frame

More information