Kestrel Aluminium Systems Limited. Product Manual Section 2 Shop Front System. Manual Version

Size: px
Start display at page:

Download "Kestrel Aluminium Systems Limited. Product Manual Section 2 Shop Front System. Manual Version"

Transcription

1 Limited Product Manual Section 2 Manual Version

2 Section 2.01 Product specifications sheet 1 Ground Floor Framing - Product Specification sheet 1 ommercial Entrance doors - Product Specification sheet 1 DD and DLM - Product Specification Section 2 ontents Section 2.02 General arrangements. Flush glaze frames sheet 1 SG Framing - Standard mullions & transoms sheet 1 SG Framing Door mid-rail with KS7 transom sheet 1 SG Framing Door mid-rail with KS4 transom sheet 1 SG Framing - Standard mullions, KS corner post sheet 1 SG Framing - Standard mullions, KS49 corner post sheet 1 SG Framing - Standard mullions, KS70 corner post sheet 1 DG Framing - Standard mullions & transoms sheet 1 DG Framing - Standard transoms and door mid-rails sheet 1 DG Framing - Standard mullions, KS46 corner post sheet 1 DG Framing - Standard mullions, KS49 corner post sheet 1 DG Framing - Standard mullions, KS40 corner post sheet 1 SG/DG Framing KS2 options Section 2.03 General arrangements. ead glaze frames sheet 1 SG Framing eaded sheet 1 DG Framing eaded sheet 1 SG Framing eaded & 4 corner post sheet 1 DG Framing eaded & 4 corner post sheet 1 SG/DG Framing eaded &, 6 and 7 options sheet 1 SG/DG Framing KS71, 74, 7, 76 Section 2.04 General arrangements. Miscellaneous sheet 1 SG Framing KS sheet 2 SG Framing KS39 on KS sheet 1 SG Framing KS64, 66, 6 Section 2.0 General arrangements. Pivot & rebate doors sheet 1 Pivot doors Typical details sheet 1 Pivot doors Typical details with fanlight KS sheet 1 Pivot doors Typical details with split fanlight KS sheet 1 Pivot doors Typical details with KS27, sheet 2 Pivot doors Typical details with KS96, 27, sheet 1 SG Rebate doors Typical details sheet 1 SG Rebate doors Typical details with fanlight sheet 1 DG Rebate doors Typical details sheet 1 DG Rebate doors Typical details with fanlight sheet 1 KS60 application double door & electric strike sheet 1 KS60 application sliding door & trim strike sheet 1 KS3/36 & KS90 details sheet 2 KS79 Typical detail Sheet

3 Section 2 ontents Section 2.0 General arrangements. Sliding doors sheet 1 uto sliding doors elevations for section keys 2.0. sheet 1 uto sliding doors Typical sections door jambs sheet 1 uto sliding doors Typical sections side screens sheet 1 uto sliding doors Typical sections head sections sheet 1 uto sliding doors Typical sections head sections sheet 1 uto sliding doors Typical sections head sections sheet 1 uto sliding doors Typical sections head sections sheet 1 uto sliding doors Thresholds, none, KS19 x 2, 19/ sheet 1 uto sliding doors Thresholds, KS, 19/ sheet 1 uto sliding doors Stall riser with pressed ZED cill sheet 2 uto sliding doors Stall riser with KS72 stubcill Section 2.0 General arrangements. uto swing doors sheet 1 uto swing head detail open in door sheet 1 uto swing head detail open out door sheet 1 uto swing head detail open in door with fanlight Section 2.0 General arrangements. Manual sliding doors sheet 1 Manual sliding doors elevations and details sheet 1 Manual sliding doors elevations and details sheet 1 Manual sliding doors elevations and details sheet 1 Manual sliding doors elevations and details sheet 1 Manual sliding doors elevations and details Section 2.0 General arrangements. Manual sliding/folding doors sheet 1 Manual sliding/folding doors elevations and details sheet 1 Manual sliding/folding doors elevations and details sheet 1 Manual sliding/folding doors elevations and head details sheet 1 Manual sliding/folding doors elevations and track details sheet 1 Manual sliding/folding doors door types Section 2.06 Miscellaneous sheet 1 Miscellaneous KS1, 16, 17 and KS10, 11, 20 sections sheet 1 Top rail options - cleat codes shown sheet 1 Mid rail options - cleat codes shown sheet 1 ottom rail options - cleat codes shown sheet 1 and gaskets SG sheet 1 and gaskets DG sheet 1 Wool-pile ID Sheet

4 Ground Floor Framing - Product Specification GROUND FLOOR FRMING The ground floor framing system is for use on commercial and retail buildings and can be used in conjunction with the commercial entrance doors. Materials: luminium profiles are extruded from alloy 6060/6063 T6 complying with the recommendations of S EN 7:1-9 Finishes: Mill finish Etched and anodised to S 397: 1991 ( ) - Silver 2 or colours on request. Polyester Powder coat paint to S EN :2004. See separate list for standard colour range available. onstruction: luminium profiles are square cut mechanically jointed and secured using stainless steel screws driven into extruded screw splines. ll joints should be sealed against water penetration., Glazing and Infil Panels: The single glazed framework is designed to accommodate glass thickness of 6mm, 6.4mm, 7.mm,.mm, 10.mm, 11.mm In addition the double glaze framework can accommodate 24 and 24.mm thick double glazing units. 2mm thickness can be glazed only in beaded frame (KS 1/2). ll glass panels should be secured in framework with glazing gaskets extruded from TPE. Glazing to be carried out in strict accordance with S 6262 and S 6206 with particular attention being taken to risk areas, which would require safety glass. The system will also accommodate solid infil panels to customers own specification and supply. Installation and Fixing: The fixing of all framework is by woodscrews through the glazing pocket into securely located plugs in the surrounding structure. It is not recommended that fixing holes are pre-drilled, as site conditions may affect their position. Where possible continuous backplates are included on perimeter framework to provide a firm fixing and bedding platform. These plates also help to eliminate frame distortion. ll fixing screws must be stainless steel or cadmium plated finish Sheet

5 ommercial Entrance Doors - Product Specification OMMERIL ENTRNE DOORS: ommercial Entrance Doors are designed for use as stand alone units or in conjunction with the ground floor framing system. Doors can be pivoted or hinged and are suitable for general traffic areas. The twin brush seal, woolpile weatherstripping together with an extensive suite of profiles, covers the majority of entrance door requirements. Materials: luminium profiles are extruded from alloy 6060/6063 T6 complying with the recommendations of S EN 7: 1-9 Finishes: Mill finish Etched and anodised to S 397: 1991 ( ) - Silver 2 or colours on request. Polyester Powder coat paint to S EN :2004. See separate list for standard colour range available. onstruction: oncealed extruded aluminium mechanical corner jointing cleats and midrail brackets are used. M10 plated mild steel threaded tie rods are used with locking nuts in the top and bottom rails to ensure further rigidity. Hardware: Door hardware is available to construct and operate pivot doors with or without finger-guard door jamb stiles, rebated open in or open out doors, manual sliding doors. utomatic doors require bespoke operating gear supplied and commissioned by specialist contractors. Limited supply as standard; Hook bolt & bar bolt dead locks & relevant face plates and armour strikes, Latch locks & relevant face plates, standard strikes or electric strikes, Round or profile cylinders to suit above - key variations possible, thumbturn options, Push bar exit devices - concealed rod, face fitted rod or push paddle types, oncealed overhead closer - end or side load, face fitted closer, Letter plates, Pad and tubular handles, flush pulls, Flush bolts, Door rollers & track, Other hardware options can be obtained on request., Glazing and Infil Panels: Doors can be supplied with tamper-proof external glazing beads for security. The system is designed to accept glass of 6mm, 6.4mm, 7.mm,.mm and 10.mm. In addition the double glaze beads can accommodate 24 or 24.mm and 2mm thickness units or infil panels. Glazing to be carried out in strict accordance with S 6262 and S 6206 with particular attention being taken to risk areas, which would require safety glass. The system will also accommodate solid infil panels to customers own specification and supply Sheet

6 DD & DO M - Product Specification Disability Discrimination ct The table below is taken from pproved Document M of the uilding Regulations edition The information given is covered by rown copyright 2003 and may only be used for private study or internal circulation within an organisation. We recommend that a copy of the pproved Document M should be obtained for further reference regarding the ccess to and the use of buildings. Download from:- REOMMEND THT LL DOORS SHOULD INLUDE NTI-FINGER TRP PIVOT STILES EFFETIVE LER WIDTH Table 2 Minimum Effective lear Opening Widths Direction and width of approach New uildings Existing uildings Minimium 300mm Straight-on (without a turn or oblique approach) t right angles to an access route at least 100mm wide t right angles to an access route at least 1200mm wide 2 77 External doors to buildings used by the general public 0 77 Note: The effective clear width is the width of the opening measured at right angles to the wall in which the door is situated from the outside of the door stop on the door closing side to any obstruction on the hinge side, whether this be projecting door opening furniture, a weather board, the door, or the door stop (see diagram). for specific guidance on the effective clear widths of doors in sports accomodation, refer to 'ccess for Disabled People'. Important Note: New buildings should have an ESS STTEMENT to detail and clarify the type, purpose and operational requirements of each door. This should be used at LL stages to ensure the correct door and door hardware are specified and agreed upon between relevant parties. Other Items for consideration are:- ll door opening furniture should contrast visually with the surface of the door and is not cold to the touch. The opening force at the leading edge of a of a door should be no greater than 20N if a greater force is required There is an unobstructed space of at least 300mm on the pull side of the door between the leading edge of the door and any return wall, unless the door is power assisted (see diagram). On double doors, at least one door should be wide enough to give the minimum effective opening width Thresholds - Steps should ideally be no greater than 1mm Sheet

7 SG Framing - Standard mullions & transoms D KS3 KS E F Fixed Glazing Typical Elevation KS7 KS6 0 KS6 KS1 D SG glazing pocket = 16.0mm 16. KS7 KS6 KS6 0 KS1 KS1 E KS KS3 KS6 KS6 10 F ill End Plate

8 SG Framing - door mid-rail with KS7 transom KS7 KS6 0 KS6 KS3 KS6 12 KS14 Midrail KS3 KS6 KS3 KS6 12 KS14 Midrail 0 KS6 10 KS ill End Plate 9 ill End Plate

9 SG Framing - door mid-rail with KS4 in transom KS3 KS6 KS3 KS6 KS3 KS6 KS4 *6 * Where this profile configuration is chosen, 3mm needs to be deducted from the aperture size to allow the glass to be manouvered into the framework. It should be noted that this reduces glass edge cover to 6mm. KS3 KS6 KS4 KS3 KS6 perture KS14 Midrail KS6 10 KS ill End Plate 9 ill End Plate

10 SG Framing - Standard mullions, KS corner post Typical 3 way corner post D D KS9 KS Fixed Glazing Typical Elevation KS KS1 KS1 KS KS4 KS Typical 2 way corner post Sheet

11 SG Framing - Standard mullion, KS49 corner post Fixed Glazing Typical Elevation 1 KS9 KS9 KS KS1 KS9 KS KS Symmetrical about centre line Typical 2 way corner post with post KS

12 *Use deep pocket opposite KS 70 mullion KS1 Variable 2 KS70 KS70 2 Variable SG Framing - Standard mullion, KS70 corner post N: orner as constructed can be sent to site as complete assembly Fixed Glazing Typical Elevation KS1 * * rackets & 2mm aluminium pressing by others (fix to only) 2 Typical variable angle corner post with 1/2 mullion KS

13 DG Framing - Standard mullions & transoms Fixed Glazing Typical Elevation D E F KS KS4 KS44 KS KS44 KS41 D DG glazing pocket = 32.00mm KS4 KS44 KS44 KS41 KS41 E KS KS42 KS44 KS6 10 F ill End Plate

14 DG Framing - Standard transoms & door mid-rails KS4 KS44 KS44 0 KS47 KS42 KS44 0 KS KS14 12 KS42 KS44 KS42 KS

15 DG Framing - Standard mullion, KS46 corner posts Typical 3 way corner post D D KS47 KS46 Fixed Glazing Typical Elevation KS KS41 KS41 KS46 KS43 KS Typical 2 way corner post

16 DG Framing - Standard mullion, KS49 corner post Fixed Glazing Typical Elevation 1 KS47 KS KS49 1 KS41 KS47 KS KS Symmetrical about centre line Typical 2 way corner post with post KS

17 *Use deep pocket opposite KS 40 mullion KS41 Variable 2 KS40 KS40 2 Variable DG Framing - Standard mullion, KS40 corner post N: orner as constructed can be sent to site as complete assembly Fixed Glazing Typical Elevation KS1 * rackets & 2mm aluminium pressing by others (fix to only) 2 Typical variable angle corner post with 1/2 mullion KS Sheet

18 SG/DG Framing - KS2 options KS2 KS2 KS2 KS9 KS KS2 KS4 22. KS2 KS KS2 KS KS32 24mm 2mm KS92 KS32 Single glazing frames KS 2 can be used with: KS KS 9 KS 4 KS 2 Double glazing frames KS 2 can be used with: KS KS 47 KS 43 KS Sheet

19 SG Framing - eaded D E F Fixed Glazing (eaded) Typical Elevation D KS92 KS KS E KS6 10 F ill End Plate

20 DG Framing - eaded Fixed Glazing (eaded) Typical Elevation KS 22 - Use with 24mm, 24.mm glazing. KS 32 - Use with 2mm glazing D E F D E KS ill End Plate

21 SG Framing - eaded & 4 orner post Typical 3 way corner post D KS92 4 Fixed Glazing (eaded) Typical Elevation KS92 2 KS92 D KS92 4 KS92 KS92 KS92 KS Typical 2 way corner post

22 DG Framing - eaded & 4 orner post Typical 3 way corner post D Fixed Glazing (eaded) Typical Elevation 2 D Typical 2 way corner post

23 SG/DG Framing - KS 6, 7, options eaded framing - Miscellaneous sections KS 42 or KS 42 woolpile 2 KS 7 flush infill section KS 6 rebate door infill section KS small single bead box (No screw ports) Scale

24 SG/DG Framing - KS71, 74, 7, KS71 2. KS7 N: Ltd supply standards; Equal angles Unequal angles Square & rectangular box sections channels Flat bars round tubes 'T' sections Please see Section 10 of current price list for details 2. KS KS74 KS 74 ead (use with KS 79 nylon 20mm centres) 79 Scale

25 SG/DG Framing - KS KS 39 fixing channel Scale 1.1 Fixed Glazing Typical Elevation Double glazing shown as example KS ottom Rail KS ottom Rail KS7 KS39 3 rush 22 KS1 Threshold 22 Door bottom rail into fixed frame KS bottom rail shown KS 33 alternative KS 39 fixing channel & KS42 woolpile Typical entre hung pivot door KS bottom rail shown KS 33 alternative Sheet

26 SG/DG Framing - KS KS 39 fixing channel Scale 1.1 Fixed Glazing Typical Elevation lternative detail Double glazing shown as example KS ottom Rail KS ottom Rail KS7 KS39 Seal 22 3 rush KS19 Threshold 22 Use KS19 threshold under KS39 to avoid notching of internal finishes around framing Door bottom rail into fixed frame KS bottom rail shown KS 33 alternative KS 39 fixing channel & KS42 woolpile Typical entre hung pivot door KS bottom rail shown KS 33 alternative Sheet

27 KS 64 ladding KS 64 ladding - Pitch = 10mm Use anodised only - clip fit not suitable for powder coat finishes SG/DG Framing - KS64, KS66, KS6 KS 66 Louvre lade KS 66 Louvre - Pitch = 0mm KS410 0 KS66 KS 66 Louvre lade See Manual Section 16 KS 6 sub cill 20 Use KS 9 end plates (Pairs) Scale Sheet

28 Pivot doors - Typical details KS2 Header ar KS1 Frame Jamb D Single Door Typical Elevation E D Double Door Typical Elevation as as KS14 Midrail KS42 Woolpile rush KS24 Header Plate KS12 Top Rail KS ottom Rail KS7 KS1 Threshold D Outside KS40 Woolpile KS40 Woolpile KS29 Stile 24mm D.G Glazing ead KS2 Slave Stile KS29 Lock Stile KS7 Plate E Outside

29 Pivot doors - Typical details with fanlight KS93 H F KS42 KS H Single Door with Fanlight Typical Elevation KS41 KS41 glass KS29 Stile F mm D.G Glazing ead KS42 Woolpile KS93 Header ar KS24 Header Plate KS12 Top Rail KS 64 Small Rail

30 Pivot doors - Typical details with split fanlight KS93 H F G KS42 KS44 H KS93 eaded Header ar KS2 Plain Header ar Double Door with Split Fanlight Typical Elevation KS93 0 KS24 Header Plate KS42 Woolpile We recommend KS 93 beaded header bar for all fan light applications N KS 93 = 0mm high KS12 Top Rail KS 2 = mm high 1mm Offset from entre Line KS41 KS41 KS43 F G

31 Pivot doors - Typical details with KS27,67 J D Single Door Typical Elevation KS14 Midrail KS42 Woolpile KS2 Header ar KS24 Header Plate KS12 Top Rail KS ottom Rail D KS7 KS 67 Flat face safety stile - Use with face fitted hardware. Open out single action doors only. KS67 3 rush KS1 Threshold 22 Outside KS1 Frame Jamb 70 KS40 Woolpile KS1 KS26 24mm D.G Glazing ead KS29 Stile KS7 KS27 KS7 Plate J KS40 Woolpile Plate Outside

32 Pivot doors - Typical details with KS96, KS27, J KS47 KS2 Fixing to plain mullion Fix KS96 to KS2 or as shown No Single Door Typical Elevation Outside J KS40 Woolpile KS41 Frame Jamb 70 KS43 KS41 Fixing to DG mullion KS Existing KS27 Pre-fix KS7 or KS to KS96 to enable a clip fit to SG/DG door hinge jamb sections with glazing pocket J KS40 Woolpile Outside 97 KS1 Frame Jamb 70 KS3 KS1 Fixing to SG mullion KS7 KS 67 Flat face safety stile - Use with face fitted hardware. Existing KS67 Open out single action doors only. J KS40 Woolpile Outside Sheet

33 SG Rebate doors - Typical details Single Door Typical Elevation D E KS14 Midrail KS1 KS61 KS12 Top Rail KS Outside KS ottom Rail D Double Door Typical Elevation KS1 Frame Jamb Plate KS61 Rebate 2 KS40 Woolpile KS29 Stile KS460 lternative KS63 Rebated Threshold KS460 ubble Seal KS37 3 rush 22 KS2 Slave Stile 3H rush 3 rush KS40 Woolpile KS1 Threshold KS29 Lock Stile KS37 22 KS92 KS92 KS E Outside Sheet

34 SG Rebate doors - Typical details with fanlight F H Single Door with Fanlight Typical Elevation H KS4 KS61 KS3 KS6 KS6 KS3 KS219 KS12 Top Rail KS34 Deep mid rail KS1 170 F

35 DG Rebate doors - Typical details KS D Single Door Typical Elevation E KS14 Midrail 0 KS62 KS12 Top Rail KS Outside KS ottom Rail D Double Door Typical Elevation KS41 Frame Jamb Plate KS62 Rebate 2 KS40 Woolpile KS29 Stile KS460 lternative KS63 Rebated Threshold KS460 ubble Seal KS37 3 rush 24mm D.G Glazing ead 22 KS2 Slave Stile 3H rush 3 rush KS40 Woolpile KS1 Threshold KS29 Lock Stile KS E Outside Sheet

36 DG Rebate doors - Typical details with fanlight H F Single Door with Fanlight Typical Elevation KS42 H KS42 KS43 KS62 KS44 KS44 KS219 KS12 Top Rail KS41 KS34 Deep mid rail 170 F

37 Double Door Meeting Stiles with Hook Lock KS 60 - application - double door & electric strike Minimum learance 4mm Lock /set Escutcheon 0d Hook Lock KS KS42 Woolpile Weatherstripping rimp the Profile to Retain the Woolpile Screw Fix KS60 with x No6 Pozi sk. Twinfast Screws ZP at nom. 200mm ctrs. Double Door Meeting Stiles with Latch lock and Electric Strike Minimum learance 4mm min. Lock /set 2.6 See DRG sheets 1-6 for KS 40 electric strike in frames 20 Escutcheon 41 Latch Lock KS Scale

38 KS 60 - application - sliding door & trim strike Sliding Door Meeting Stiles with Hook Lock Minimum learance 4mm Lock /set Escutcheon Hook Lock KS KS42 Woolpile Weatherstripping rimp the Profile to Retain the Woolpile Screw Fix KS60 with x No6 Pozi sk. Twinfast Screws ZP at nom. 200mm ctrs. Double Door Meeting Stiles with Latch lock and Trim Strike min. Lock /set 2.6 Minimum learance 4mm Some Modification to the Trim Strike Plate may be necessary to allow and ensure that the latch engages correctly 20 Escutcheon 06b Latch Lock KS Scale

39 KS 3 / 36 & KS 90 details 2 KS ottom Rail. Silicone Sealant in Severe onditions KS36 (in 3M Lengths) No Self Tapping Screws KS3 (in 3M Lenghts) 3 rush * (in 3M Lengths) 12. KS1 Threshold ottom pivot and lock nut 7 1 KS90 Drain Threshold Mild steel plated tapping block 6mm Ø lear Holes for Drainage * 3H High Draft Seal rush also available Scale Sheet

40 KS 79 detail KS ottom Rail KS7 Silicone sealant No6 x 1/2" Pan head self tapping screw 3 KS KS1 Threshold KS79 Use drip bar at threshold as shown on pivot door - Ends will require mitre cut on plan to avoid clashing with KS26 if used KS79 Do not use on sliding or sliding/folding doors KS79 or KS219 can be used to protect head of open out rebated doors, with or without wool-pile inserted. 27. Scale Sheet

41 Typical bi-parting sliding door elevation uto sliding doors - elevations for section keys G H Slide Slide K J J Typical single sliding door elevation with glazed fanlight L M See pages incl. for typical details as indicated. IMPORTNT NOTE: D 2.0. E 2.0. F These are typical details only! Slide Setting out of door leafs and header bars etc. dependant on specific operator design per supplier - ontact supplier for door leaf / header bar details

42 uto sliding doors - Typical sections door jambs 7. 0 Length of 17 KS4 M6 * 30 Meeting Stile in Open Position 102 minimum (to avoid finger trap) KS92 KS2 Meeting Stile in losed Position 4 KS29 KS KS7 KS KS1 KS 30 KS 3 used on plain mm stile - check gap and woolpile height to avoid binding when leaf is closing Gap KS 3 KS2 KS29 KS92 KS92 KS4 4 KS7 KS7 KS1 KS4 D E KS1 2.0.

43 uto sliding doors - Typical sections side screens KS409 butt hinge KS92 KS92 KS2 71.F & G top & bottom * KS7 KS1 * Internal safety screen optional - * see note regarding gap to clear sliding leaf *onfirm Gap KS4 KS92 KS7 KS s 2.0. KS1 KS4 s E 2.0. No internal safety screen shown KS92 KS4 KS7 KS4 F KS1 KS

44 uto sliding doors - Typical sections head sections KS2 heck clearance required to open cover KS70 KS3 Use KS 70 to reduce the overall height of the header bar - N See note on opening the cover 21 Typical uto Unit KS1 KS7 KS Outside Safety screen if required 19 H

45 uto sliding doors - Typical sections head sections KS2 heck clearance required to open cover KS70 KS3 Use KS 70 to reduce the overall height of the header bar - N See note on opening the cover 21 Typical uto Unit Outside Safety screen if required 19 KS3 KS6 G Sliding door leaf

46 uto sliding doors - Typical sections head sections heck clearance required to open cover KS3 21 Typical uto Unit KS1 KS7 KS Outside Safety screen if required KS3 KS6 L

47 uto sliding doors - Typical sections head sections heck clearance required to open cover KS3 21 Typical uto Unit KS3 KS6 Outside Safety screen if required Sliding door leaf KS3 KS6 M

48 uto sliding doors - Thresholds 19x2, 19/6 KS Typical bottom rail No threshold Outside J KS7 10 FFL 3 KS Typical bottom rail KS 19 threshold x 2 Outside KS7 J FFL FFL J Raised floor level internally 3 KS19 KS 3 KS6 M6 M6 KS7 KS19 Typical bottom rail KS 19 / 6 thresholds Only use with raised floor internally i.e. tiled KS Outside

49 uto sliding doors - Thresholds 19/9 & KS Typical bottom rail KS 19/9 thresholds Outside J KS7 10 FFL KS9 3 M6 KS19 10 KS 19/9 thresholds used with multiple internal door leafs or safety screens 12. KS Typical bottom rail KS threshold Outside FFL J KS 10 3 KS7 M6 3H KS threshold used with multiple internal door leafs or safety screens

50 uto sliding doors - stall riser KS3 KS6 Will apply to any frame type where stall riser is present Pressed angle or zed tray to provide drainage cill under mullion & transoms (vailable as made to order item only) Seal continuously at rear of framing K Typical stall riser to construction details

51 uto sliding doors - stall riser KS3 KS6 1 KS72 Will apply to any frame type where stall riser is present KS72 stubcill with drain slots to external face Seal continuously at rear of framing K Typical stall riser to construction details Sheet

52 uto swing - Head detail - Open in door lternative box section KS72 Single Door Typical Elevation Typical uto Unit KS0 10 KS93 7.E 12 0 KS24 KS77 Deep top rail KS 77 used to allow easier fitting of operating arm Outside Door opens IN uto swing doors must be constructed with finger guard stile KS 26/96 & KS 27/67 on hinge jamb See page for typical details Sheet

53 uto swing - Head detail - Open out door uto swing doors must be constructed with finger guard stile KS 26/96 & KS 27/67 on hinge jamb See page for typical details Single Door Typical Elevation Subject to size of operator unit additional sections may be required at head to provide clearance to structure and internal reveal etc. KS 72 shown as example Typical uto Unit KS72 17 KS93 7.E 0 KS24 KS77 Deep top rail KS 77 used to allow easier fitting of operating arm Outside 12 Door opens OUT Sheet

54 uto swing - Head detail - Open in door with fan light uto swing doors must be constructed with finger guard stile KS 26/96 & KS 27/67 on hinge jamb See page for typical details Single Door Typical Elevation Typical uto Unit KS0 19 KS93 7.E 0 KS24 KS77 Deep top rail KS 77 used to allow easier fitting of operating arm Outside KS3 KS6 Door opens IN

55 Manual sliding doors - elevation & details KS 1 ROLLERS Max. Glazed door leaf weight 200 KG./Pair Manual i Parting Doors Typical Elevation 30 KS1 6 M6 1 3/4" x 1" x 1/" channel anti lift blocks (mm) KS2 Use KS1 & KS7 if concealed fixings are required at head KS77 KS 40 or KS Locate anti lift blocks over roller positions where possible Outside 9 KS Example shows track and thresholds fixed to top of floor level KS 37 uses KS 3 or KS 3 H draft strips KS 19 KS 37 KS 1 10 KS2 TRKS MUST STRIGHT and LEVEL KS 19 JMS MUST E STRIGHT and PLUM 12. FFL Denotes 10.7mm thick support blocks between roller KS 1 & KS37 (Not by Kestrel) Sheet

56 Manual sliding doors - elevation & details D E KS 1 ROLLERS Max. Glazed door leaf weight 200 KG./Pair TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Manual i Parting Doors Typical Elevation N KS 60 does NOT clear KS 1 4 Lock /set 30 KS60 KS42 Woolpile 20 Escutcheon KS30 0.P 23 KS31 E Hook Lock 04.H KS92 KS92 KS Screw Fix KS60 with x No6 Pozi sk. Twinfast Screws ZP at nom. 200mm ctrs. KS30 71.F & G top & bottom 47 KS41 Woolpile KS92 9 KS3 KS1 KS D

57 Manual sliding doors - elevation & details F KS 1 ROLLERS Max. Glazed door leaf weight 200 KG./Pair F TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Manual i Parting Doors Typical Elevation 16 KS3 KS6 Track & guide detail for 4 panel door - See drg sheet 1 F G KS3 KS

58 Manual sliding doors - elevation & details H KS 1 ROLLERS Max. Glazed door leaf weight 200 KG./Pair TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Manual i Parting Doors Typical Elevation Line of KS 19 KS 2 will need cut out as hatch to fit into head section KS 1 Line of KS 1 & KS 2 KS2 20 Escutcheon 0.P 23 KS31 Hook Lock 04.H KS KS7 KS1 H Line of KS 19 Outside 2.0.2

59 Manual sliding doors - elevation & details H s H Manual i Parting Doors Typical Elevation Four panel door KS 1 ROLLERS Max. Glazed door leaf weight 200 KG./Pair TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM H KS30 47 KS3 KS92 2 x KS41 Woolpile KS KS92 KS ar olt Lock (2mm /Set) with KS 27 Profile ylinder and KS 20 Flat Escuthceon Plates Outside N: rass track alternative available to special order - please ask for details

60 Manual sliding/folding doors - elevation & details Sliding Folding door sets Vistafold operating gear Maximum door sizes: Weight per leaf = 70 kg Width per leaf = 900 mm Height per leaf = 2700mm Manual Sliding/Folding Doors Typical Elevation Three panel door ombinations of three or five panel doors sets are possible TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Three Leaf Plan 20 See drg also KS 71.F Inside KS 71.F to top and bottom of stile (1mm throw) KS1 KS29 KS92 KS29 KS29 KS Pack hinge jambs full height to prevent distortion when fixing Outside

61 Manual sliding/folding doors - elevation & details D Sliding Folding door sets Vistafold operating gear Maximum door sizes: Manual Sliding/Folding Doors Typical Elevation Three panel door ombinations of three or five panel doors sets are possible Weight per leaf = 70 kg Width per leaf = 900 mm Height per leaf = 2700mm TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Three Leaf Plan This leaf acts as locking/access leaf: Open in rebated door leaf with hook bolt dead locks N: Door leaf cannot have projecting handles/furniture internally Door leaf cannot have overhead closers/restrictor arms or powered closers etc. Inside 10 Hook Lock 0.P 04.H KS29 KS29 KS92 KS92 KS29 23 KS D KS1 4 4 Outside

62 Manual sliding/folding doors - elevation & head details E Sliding Folding door sets Vistafold operating gear Maximum door sizes: Manual Sliding/Folding Doors Typical Elevation Three panel door ombinations of three or five panel doors sets are possible Weight per leaf = 70 kg Width per leaf = 900 mm Height per leaf = 2700mm TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM lternative head detail with beads to give fan light option over doors Inside Outside 17 4 Top guide KS61 KS12 Flush bolt position (1mm throw) at head section See KS6 KS6 KS61 1 E E Sheet

63 Manual sliding/folding doors - elevation & track details Sliding Folding door sets Vistafold operating gear Maximum door sizes: F Manual Sliding/Folding Doors Typical Elevation Three panel door ombinations of three or five panel doors sets are possible Weight per leaf = 70 kg Width per leaf = 900 mm Height per leaf = 2700mm TRKS MUST STRIGHT and LEVEL JMS MUST E STRIGHT and PLUM Inside Outside F F Flush bolt position (1mm throw) at track section See ottom roller 4. KS KS37. Line of door stile KS69 1 KS69 26 Internal floor finish Inside Outside. 12. KS9 lternative threshold detail with KS 9 track to give flush floor level Sheet

64 Manual sliding/folding doors - types Typical arrangements - all leafs fold to one side. Typical Three panel door - hinged to one side. Typical Five panel door - hinged to one side. Typical arrangement with sliding folding and single hinged leaf opposite (ok with 3 & panel designs). Typical Three panel door - hinged to one side with single opposing hinged leaf. System allows for all door leafs to fold to the internal side only and allows use of fully rebated head and jamb sections, rebated track/threshold profile can be used to provide rebate to all four sides for improved weathering. lternative track (KS 9) will give flush floor levels internally & externally if preferred Sheet

65 Miscellaneous - KS1,16,17, 10,11,21 sections Single Glaze beads - 1mm - Kestrel recommend KS 91 & 92 (17mm) 1 KS1 KS16 KS17 R0 47 KS 10 - Plain Radius Stile KS 20 - leat 47 KS 11 - Single Woolpile Radius Stile 47 KS 21 - Single Woolpile Wide Stile Scale

66 Top rail options. leat codes shown Top Rails - options KS 12 - mm top rail KS ut and prepared cleat (Ex KS20) KS 77 - mm top rail KS ut and prepared cleat (Ex KS20) KS - mm top rail (uto sliding doors) KS 90. ut and prepared cleat (Ex KS20) Scale

67 Mid rail options. leat codes shown Mid Rails & Laybars - options KS - 30mm mid rail KS 90. ut and prepared cleat (Ex KS20) 10 KS 9-10mm laybar No cleat ngle brackets reqd (Not by Kestrel) KS 14-0mm mid rail KS ut and prepared cleat (Ex KS20) KS mm mid rail KS ut and prepared cleat (Ex KS20) Scale

68 ottom rail options. leat codes shown ottom Rails - options KS 77 See drawing Sheet 1 Used as bottom rail on manual sliding doors only 10 KS - mm bottom rail KS 90. ut and prepared cleat (Ex KS20) KS 33-10mm bottom rail KS ut and prepared cleat (Ex KS20) Scale

69 & gaskets - SG Pocket framing Retaining Gasket Wedge Gasket Thickness Wedge Gasket & Gaskets SG Wedge Gasket KS 471 KS 476 6mm KS 476 KS 476 KS 471 KS mm KS 476 KS 476 KS 472 KS 477.mm KS 477 KS 477 KS 473 KS 47 10mm KS 47 KS 47 KS 473 KS mm KS 47 KS mm KS 479 KS 479 & gaskets - SG beads Retaining Gasket Wedge Gasket Thickness Wedge Gasket Wedge Gasket KS 471 KS 476 6mm KS 476 KS 476 KS 471 KS mm KS 476 KS 476 KS 472 KS 477.mm KS 477 KS 477 KS 473 KS 47 10mm KS 47 KS 47 KS 473 KS mm KS 47 KS mm KS 479 KS 479 & gaskets - SG bead framing - s SG beads N - Extrusion glazing pockets and glass thickness have tolerances and may vary from standard sizes on drawings. lways take alternative gaskets to site (thicker & thinner) to avoid delays in glazing up Sheet

70 & gaskets - DG Pocket framing Retaining Gasket Wedge Gasket Thickness Wedge Gasket & Gaskets DG Wedge Gasket KS 473 KS mm KS 477 KS 477 KS 473 KS mm KS 477 KS N 2mm glass thickness can only be glazed in bead frame sections KS 1/2/4 with KS 32 glazing bead See below & gaskets - DG beads KS 22 Retaining Gasket Wedge Gasket Thickness Wedge Gasket Wedge Gasket KS 473 KS mm KS 477 KS 477 KS 473 KS mm KS 477 KS & gaskets - DG beads KS 32 Retaining Gasket Wedge Gasket Thickness Wedge Gasket Wedge Gasket KS 473 KS 477 2mm KS 477 KS 477 KS 473 KS mm KS 477 KS & gaskets - DG bead framing - S DG beads (KS 22 & 32) KS32 KS32 N - Extrusion glazing pockets and glass thickness have tolerances and may vary from standard sizes on drawings. lways take alternative gaskets to site (thicker & thinner) to avoid delays in glazing up Sheet

71 Woolpile ID KS No. Reference Match Profile Design Gap KS KS29 KS31 KS1 Grey Woolpile KS KS3 Grey Woolpile KS41 KS KS4 KS73 Grey Woolpile KS lternative to above and KS11 KS26 KS21 KS lternative to above KS KS39 Grey Woolpile KS KS61 KS63 KS62 KS24 Grey Woolpile KS460 Recommended for KS61, 62 and 63 lack TPR ubble Seal KS36 KS7 KS37 lack rush Strip 3H 24 lack rush Strip 2.2 KS36 KS7 KS sheet

Kestrel Aluminium Systems Limited. Product Manual Section 22 TB Commercial Door. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 22 TB Commercial Door. Manual Version Kestrel Aluminium Systems Limited Product Manual Section 22 TB Commercial Door Manual Version 23.0.1 PAS24: 2012 Section 22.01 Product Specification 22.01.01 sheet 1 Product specification 22.01.01 sheet

More information

Kestrel Aluminium Systems Limited. Product Manual Section 3 Shop Front System - Fabrication. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 3 Shop Front System - Fabrication. Manual Version Limited Product Manual Section 3 - Fabrication Manual Version 23.0.1 Section 3 Contents Section 3.01 Fabrication - Guidelines for cutting and prepping 3.01.01 sheet 1 General guidelines for cutting and

More information

SPW500 Thermal Framing SPW500. Product Assembly Manual 2012 Thermal Framing

SPW500 Thermal Framing SPW500. Product Assembly Manual 2012 Thermal Framing SPW500 Thermal Framing SPW500 Product Assembly Manual 2012 Thermal Framing SPW.500.ii 01.12 SPW500 Thermal Framing Introduction The Company Senior Architectural Systems Ltd are a group of companies based

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

Installation Guide. Bi-fold Doors

Installation Guide. Bi-fold Doors Installation Guide Bi-fold Doors Installation Guide Components box 1. 6. 2. 3. 7. 5. 4. 8. Contents 1. Fixing plugs 2. Wedge gasket 3. Bottom trolley 4. Top trolley 5. Magnetic keep (x 2 if door height

More information

For Installer. Duration Windows. Assembly Guide Durafold 1000

For Installer. Duration Windows. Assembly Guide Durafold 1000 For Installer Assembly Guide Durafold 1000 Contents Title Page Number Handling Manual Blinds 4 Handling Electronic Blinds 5 Drainage 63 Outer Frame Assembly (Kit Form Door Only) 7 15mm Low Threshold Assembly

More information

Installation - Sub Cills

Installation - Sub Cills Installation - Sub Cills Fitting of Subcill Drainage paths through the sub-cill can be seen on the illustration alongside so care must be taken to ensure they are not obstructed and that screw fixings

More information

VEKA GROUP PATIO DOOR PATIO DOOR PATIO DOOR UNCONTROLLED DOCUMENT AUTHOR PHIL GREGORY VEKA _IMAGINE PATIO_INSTALLER AID

VEKA GROUP PATIO DOOR PATIO DOOR PATIO DOOR UNCONTROLLED DOCUMENT AUTHOR PHIL GREGORY VEKA _IMAGINE PATIO_INSTALLER AID VEKA GROUP VEKA _IMAGINE PATIO_INSTALLER AID UNCONTROLLED DOCUMENT VEKA GROUP USE OF THIS MANUAL Guidelines Advice & General Information. Although it is possible to manufacture a five metre four pane patio

More information

350/500 HEAVY WALL TM IR ENTRANCES 1

350/500 HEAVY WALL TM IR ENTRANCES 1 JUNE, 202 30/00 HEAVY WALL TM IR ENTRANCES FEATURES Blast Mitigation Product Features 30 medium stile has 3-/2" vertical stile, 3-/2" top and 6-/2" bottom rail 00 wide stile has " vertical stile, " top

More information

Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors

Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE BALLISTIC GRADE Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Manufacturer Configurations Narrow

More information

. crealco V I S TA F O L D B O T T O M R O L L E R F O L D I N G D O O R Index Legal Disclaimer 4 Profile Identification 5-7 Hardware Identification 8

. crealco V I S TA F O L D B O T T O M R O L L E R F O L D I N G D O O R Index Legal Disclaimer 4 Profile Identification 5-7 Hardware Identification 8 . crealco V I S TA F O L D B O T T O M R O L L E R F O L D I N G D O O R VISTAFOLD SYSTEM PRODUCT MANUAL 2013 Wispeco (Pty) Ltd, All Rights Reserved Revision: June 2013 . crealco V I S TA F O L D B O T

More information

ASS 70 FD folding / sliding door. Installation Guide

ASS 70 FD folding / sliding door. Installation Guide ASS 70 FD folding / sliding door Installation Guide IMPORTANT! These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the installation.

More information

Smarts Shopline is a non-thermally broken system designed for all ground floor treatments and high traffic doors

Smarts Shopline is a non-thermally broken system designed for all ground floor treatments and high traffic doors Smarts is a non-thermally broken system designed for all ground floor treatments and high traffic doors Unless specified we will use the following defaults: - We always view everything from the outside

More information

Method of Build 1. General

Method of Build 1. General Method of Build 1 General GLAZED ELEVATIONS Viso Double Glazed in glazed form differs from many other systems as the vertical joints can have Viso dry joints or the unique HIDDEN mullion post between glazed

More information

930 Series Mortice Exit Device

930 Series Mortice Exit Device 930 Series Mortice Exit Device BS EN 1125:1997+A1:2001 Classification Code 37601322B The Adams Rite 930 Series Mortice Exit Device is a life safety device which is designed to fit timber or hollow steel

More information

Aurora Door Concepts Practicality in Design

Aurora Door Concepts Practicality in Design Aurora Door Concepts Practicality in Design Aurora Door Concepts This collection of commercial doors and related accessories has been designed to enhance our partition suites. The range has evolved due

More information

STII. Commercial Door

STII. Commercial Door Commercial Door System and hardware working together to simplify fabrication Since its launch, the STII door has been recognised as an exceptional product in terms of performance and fabrication. STII

More information

350/500 Heavy Wall TM IR Entrances

350/500 Heavy Wall TM IR Entrances SEPTEMBER, 207 FEATURES Hurricane Resistant Product Blast Mitigation Product Features 50 Heavy Wall TM IR medium stile has vertical stiles, top and 6-/ (65.) bottom rails 500 Heavy Wall TM IR wide stile

More information

Vertical Slider Section Detail

Vertical Slider Section Detail Vertical Slider Section Detail PRODUCT GUIDE Main & Bead Profiles 128 42 69 VS01 - Outer frame 150 139 210 189 60 52 52 52 48 30 42 60 18 72 90 18 60 VS02 - Cill VS14 - Cill 18 VS03 - Top Sash VS04 - Standard

More information

MAX Bifold Door. [ [ Bifold Door

MAX Bifold Door. [  [  Bifold Door MAX TM 1 Bifold Door 225 EDGE Architectural Glazing Systems: MAX Technical Manual, January 2015 225 2 Some typical configurations are depicted below from 2 to panel doors. Many more panel configurations

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

Coburn Interior Sliding Systems. Coburn COBURN SLIDING SYSTEMS

Coburn Interior Sliding Systems. Coburn COBURN SLIDING SYSTEMS Coburn Interior Sliding Systems Coburn COBURN SLIDING SYSTEMS Interior Sliding Door Gears FOR CUPBOARDS, WARDROBES, INTERIOR SLIDING AND FOLDING DOORS A comprehensive range of top hung and bottom rolling

More information

In-line Patio Fabrication & Installation

In-line Patio Fabrication & Installation In-line Patio Fabrication & Installation Instructions 2 Pane Patio p2 Cutting and Preparation p2 Welding and Cleaning p2 Assembly p2 Fabrication Instructions for 3/4 Pane Lock Style p3 Installation (removable

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

DOOR BiFOLD DOOR SET (3 + 1)

DOOR BiFOLD DOOR SET (3 + 1) 3 4 DOOR BiFOLD DOOR SET (3 + 1) Bespoke and Standard Sizes 3.6M - 3590mm W x 2090mm H 4.0M - 3990mm W x 2090mm H IB73HEP431 - ISSUE B All products must be installed in accordance with accepted good trade

More information

Adjustment Has adjustment strike block screw for sealing action adjustment.

Adjustment Has adjustment strike block screw for sealing action adjustment. RP8 Si A concealed, acoustic automatic door bottom silicon seal for medium temperature smoke and fire door applications. RP8Si is spring loaded to lift clear off the floor as soon as the door leaf is opened

More information

Folding sliding doors

Folding sliding doors Folding sliding doors Standard program overview Folding sliding doors Folding sliding doors single and double-skinned Product Dimensions in mm width/height Leaf thickness Min. headroom Min. lateral projection

More information

Kestrel Aluminium Systems Limited. Product Manual Section 12 60mm Polyamide Window System. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 12 60mm Polyamide Window System. Manual Version Limited Product Manual Section 12 mm Manual Version 23.0.1 Section 12.01 Product Specification 12.01.01 sheet 1 mm Window System Product Specification 12.01.01 sheet 2 mm Window System Product Specification

More information

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

Hardware Fitting Accessories Bolts

Hardware Fitting Accessories Bolts Lever action flush bolt With slide Width: 19 mm Stroke (a): 25 mm 1 Flush bolt 1 Set of fastening material With lever arm Width: 19 mm Stroke (a): 18 mm 1 Flush bolt 1 Set of fastening material Stainless

More information

ASS 70 FD folding/sliding door installation guide

ASS 70 FD folding/sliding door installation guide ASS 70 FD folding/sliding door installation guide 2 Preparation IMPORTANT These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the

More information

350 IR ENTRANCES INDEX

350 IR ENTRANCES INDEX 50 IR ENTRANCES INDEX Hurricane Resistant Product PICTORIAL VIEW... IR 500 ENTRANCE FRAMING DETAILS... 4 IR 50 ENTRANCE FRAMING DETAILS... 5 TRIFAB VG 450 FRAMES / 600 WALL SUB-FRAMES...6 INFILL OPTIONS

More information

Method of Build 1. Fire. Sound

Method of Build 1. Fire. Sound Method of Build 1 General Viso Fire & Acoustic in the solid form differs from most other systems as it can be erected using 12.5mm & 15.0mm boards within the same Aluminium framework. Also hidden fix board

More information

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS Page 2-9: Installation Instructions, Figures 1, 2, & 3 Page 10-12: Figures A-1, A-2, & A-3: Installation

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features OCTOBER, 05 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom rail.

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features SEPTEMBER, 07 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom

More information

Kestrel Aluminium Systems Limited. Product Manual Section 11 Thermal Framing System - Fabrication. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 11 Thermal Framing System - Fabrication. Manual Version Limited Product Manual Section 11 - Fabrication Manual Version 23.0.1 Section 11.01 Fabrication 11.01.01 sheet 1 General guidelines for cutting and bar preparation Section 11 Contents Section 11.02 Fabrication

More information

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS XL JOINERY LTD LA PORTE VISTA MODULAR 3 2090mm High x 4687mm Wide ASSEMBLY INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS FULLY PRIOR TO STARTING INSTALLATION. IT IS STRONGLY RECOMMENDED THAT A COMPETENT

More information

Coburn Straightaway Door Gear

Coburn Straightaway Door Gear Coburn Straightaway Door Gear Straightaway Sliding Door Gear FOR TIMBER OR METAL DOORS EITHER TOP HUNG OR BOTTOM ROLLING Index TOP HUNG STRAIGHT SLIDING DOOR GEARS SINGLE TRACK RUNS A comprehensive range

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

PRODUCT DATA CATALOG

PRODUCT DATA CATALOG PRODUCT DATA CATALOG CONTENTS PAGE STANDARD ELEVATIONS 2 STANDARD ELEVATIONS 3 DOOR SPECIFICATIONS 4 LOUVER SPECIFICATIONS 5 GLAZING SPECIFICATIONS 5 DOOR HANDING CHART 6 CLINE STANDARD HARDWARE LOCATIONS

More information

C D. Secondary Glazing Fixed Unit. Do not scale 1 to 1. Frame 301 Face Fix. 19.8mm. Typical Elevation. Top hung over fixed.

C D. Secondary Glazing Fixed Unit. Do not scale 1 to 1. Frame 301 Face Fix. 19.8mm. Typical Elevation. Top hung over fixed. Secondary Glazing Fixed Unit 19.8mm 14.0mm Frame 301 Face Fix Top hung over fixed Fixed unit Fixed unit using overlap section 310 Glazing available in 4mm 6mm and 6.4mm Laminate Glass o not scale 1 to

More information

patio door installation guide

patio door installation guide patio door installation guide Measuring & surveying p2 Mechanical jointing p5 Installation p5 Hardware adjustment p7 Sealing of outer frame p7 Cleaning p7 Walk through clearances p8 Minimum and maximum

More information

2.01 Standard Entrances Description

2.01 Standard Entrances Description 2.01 Standard Entrances Description Description Tubelite Standard Entrances have an outstanding reputation for craftsmanship and strength. The Narrow Stile Door has a face dimension of 2 1/8" and is designed

More information

Installation Instructions

Installation Instructions TEL: 09 579-8895 FAX: 09 579-2933 EMAIL: sales@nzfiredoors.co.nz NZ Fire Doors Ltd, 89 Gavin Street, Ellerslie, PO Box 12709, Penrose 1642, Auckland, New Zealand. www.nzfiredoors.co.nz Installation Instructions

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information

A F LCON PANEL PRODUCTS LTD

A F LCON PANEL PRODUCTS LTD FA LCON PANEL PRODUCTS LTD Experience suggests that the coordination of doorsets with floor levels can be particularly difficult when considering regulations relating to threshold gaps and the possibility

More information

SCW Series Product Assembly Manual 2008 SCW CURTAIN WALL

SCW Series Product Assembly Manual 2008 SCW CURTAIN WALL SCW Series Product Assembly Manual 2008 SCW CURTAIN WALL 2.1.ii 07.08 SCW Curtain Wall Introduction The Company Senior Aluminium Systems are a group of companies based in the United Kingdom supported through

More information

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2 911404-00 Concealed Vertical Rod Exit Device 33/3547A Installation Instructions Devices covered by these instructions: 33/3547A and 33/3548A Concealed Vertical Rod Exit Device 33/3547A-F and 33/3548A-F

More information

9.1. Door Assembly Coordination. Ÿ Architrave is not described in

9.1. Door Assembly Coordination. Ÿ Architrave is not described in 9.1 Introduction: This document provides for general guidance with regard to the coordination of bespoke door assemblies. The document includes recommendations with regard to the reference points generally

More information

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents. Pocket Door Kit PD1 / PD2 Installation Instructions Kit Contents. 1, Create Rough Opening In Stud Wall Construct rough opening ensuring all sides are square and level. Rough opening should be; Height =

More information

SIG Awning / Casement / Fixed Lite 100

SIG Awning / Casement / Fixed Lite 100 TYPICAL FRAME ASSEMBLY - AWNING WINDOW 07-01 85720-2 GASKET EXT FL JAMB 100 BS201 (3471) HEAD HINGED 100 86064 TRIM FIN A 83963 SCREW SQ 8G X 1.0 PAN PP SS #2 85737 GASKET EXT FL TRANSOM 85720-1 86065

More information

HENDERSON. Securefold Bottom Rolling. Fitting Instructions For Bottom Rolling External Doors with Morticed hinges SYSTEM CAPACITY.

HENDERSON. Securefold Bottom Rolling. Fitting Instructions For Bottom Rolling External Doors with Morticed hinges SYSTEM CAPACITY. 1 HERSON Securefold Bottom Rolling HEADBOARD LINTEL 9X4 Diagram 1 2,7 25 19 Fitting Instructions For Bottom Rolling External Doors with Morticed hinges 94SC SUPPORT CHANNEL 94P CHANNEL 14 2 SYSTEM CAPACITY

More information

ASS 70.HI Lift/Sliding and Sliding Doors Installation Guide

ASS 70.HI Lift/Sliding and Sliding Doors Installation Guide ASS 70.HI Lift/Sliding and Sliding Doors Installation Guide 2 Schueco ASS 70.HI Lift/Sliding and Sliding Doors Installation Guide Installation guide IMPORTANT The ASS 70.HI door should be fitted by competent

More information

INTRODUCTION. EqunioxRoof.com. Pro Tip

INTRODUCTION. EqunioxRoof.com. Pro Tip INSTALLATION MANUAL INTRODUCTION The Equinox Louvered Roof System is designed to be installed in an aluminum frame. All these sections are 1/8" thick extruded aluminum. All engineering for this system

More information

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S Trim type: Shadow gap Fire rating: FD0 Enigma Pocket sliding door systems 1 2 FD0 S Installation instructions Thank you for choosing Enigma To ensure the installation process is simple and efficient we

More information

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2 Evolve bi-fold Installation Guide 1. Before you start p2 8. Door restrictor- optional p9 2. Measuring and surveying p2 3. Configuration details p4 4. Installation p5 5. Glazing p5 6. Glazing packer details

More information

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 CONTENTS SECTION A4...IMPACT RATED ENTRANCES* Impact Rated Entrances CONTENTS PAGE FINISH GROUPS... A4/3 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 A4/1 350 IR/500 IR BASE DOOR DOOR CHASSIS...

More information

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Phone # 800-440-8785 www.lajolladoors.com La Jolla Doors Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Thank you for choosing La Jolla Doors In this manual you will

More information

Oxford Stalls Installation Instructions

Oxford Stalls Installation Instructions Oxford Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 8/15/17 Before You Start Typical stall sizes are 10 x 10, 12 x 12 or

More information

Series 424 CentreGLAZE Framing

Series 424 CentreGLAZE Framing Series 424 CentreGLAZE Framing Double Glazed 102mm COMMERCIAL SERIES Photo courtesy of All Weather Windows DATE: MAY 2013 REPLACES: MARCH 2008 COMMERFIAL FRAMING Series 424 KEY FEATURES/PERFORMANCE CHARACTERISTICS

More information

Liniar Window. installation guide

Liniar Window. installation guide Liniar Window installation guide This installation guide is designed to show you the best way to fit Liniar windows, and covers all styles of window made from Liniar s lead-free 70mm PVCu profile. Not

More information

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel Mortise Locks deadlatch Deadbolt Hookbolt Function: Deadbolt, Hookbolt, Deadlatch Backset: 31/32", 1-1/8", 1-1/2" Face Plate: 1"W x 6-7/8" L - Aluminum Case Dimensions: 7/8"W x 6"L x Depth specific to

More information

Vinyl Sliding Glass Door Assembly Instructions

Vinyl Sliding Glass Door Assembly Instructions Vinyl Sliding Glass Door Assembly Instructions SERIES SGD 5470/5570 Para instrucciones en español, visite: http://bit.ly/pgtassemblyinstructions Parts List ITEM 4 5 6 7 8 9 0 4 5 6 7 8 SGD 5470/5570 PARTS

More information

Aluminium Window Scheme to BS4873 & PAS24:2016

Aluminium Window Scheme to BS4873 & PAS24:2016 SCOPE OF CERTIFICATION Aluminium Window Scheme to BS4873 & PAS24:2016 Manufacturer of Enhanced Security Windows in accordance with the Exova BM TRADA Q-Mark Scheme requirements. (Check with Secured by

More information

Metal Sound Retardant Door Hardware Information Bulletin

Metal Sound Retardant Door Hardware Information Bulletin 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Metal Sound Retardant Door Hardware Information Bulletin

More information

Privacy Wall Glass Selections - Polished Edge Slider Door

Privacy Wall Glass Selections - Polished Edge Slider Door Privacy Wall Glass Selections - Polished Edge Slider Door 3/6" HEX BIT PUTTY KNIFE #2 ACR BIT SUCTION CUP HOLDERS DOOR LEAF: Satin Tempered Clear Tempered LOCTITE 425 SIDE LIGHT ETCHED GLASS STYLES: Satin

More information

MANUFACTURING INC. Specifications

MANUFACTURING INC. Specifications Page 1 of 4 GENERAL 11 Aluminum security screen doors must be tested by a recognized testing laboratory to conform to SMA 6001-2002 Proposed American National Standard Specifications for Metal Protection

More information

Gyproc Proflex Access Panels - Installation Guidance Notes

Gyproc Proflex Access Panels - Installation Guidance Notes Gyproc Proflex ccess Panels - Installation Guidance Notes The following notes are intended as guidance only, depicting the basic sequence of installation. In practice, consideration should be given to

More information

custom entrances and hardware

custom entrances and hardware custom entrances and hardware Table of Contents Custom Entrances (B1) Loose Hardware and Fabrication (B2) Custom Entrances and Modifications (B1) Table of Contents Entrance Door Handing page 3 CUSTOM ENTRANCES

More information

YSD 400 Sliding Door System Installation Manual

YSD 400 Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation

More information

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN 6ft Lean-To LEAN-TO Assembly Instructions 04/02 6ft Lean-To Greenhouse Base Plan Introduction/Tools/Contents / / Contents This is a copy of our Lean-To greenhouse base plan.

More information

Hardware Fitting Accessories Door Seals

Hardware Fitting Accessories Door Seals Areas of application Protection against cold, draught and vermin Reduces light leakage, sound insulation Smoke control, fire resistance Reduces the energy consumption of air conditioning systems (see following

More information

CoFold Non-Mortice. Fitting Instructions for top hung exterior folding doors SYSTEM CAPACITY. Diagram 1. Diagram 2. Diagram 3.

CoFold Non-Mortice. Fitting Instructions for top hung exterior folding doors SYSTEM CAPACITY. Diagram 1. Diagram 2. Diagram 3. 1 CoFold Non-Mortice Fitting Instructions for top hung exterior folding doors Diagram 1 SYSTEM CAPACITY Maximum leaf height Maximum leaf weight Maximum leaf width Maximum leaf thickness - 3300mm - 100kg

More information

Installation Instructions

Installation Instructions Installation Instructions Angle orner & Round Enclosures efore Installation please check that your shower enclosure system is undamaged Please read these instructions carefully Oct 2015 TOOLS REQUIRE Electric

More information

BOLOTA 316 OTHER PRODUCT RANGES SERVICE

BOLOTA 316 OTHER PRODUCT RANGES SERVICE BOLOTA 316 BOLOTA 316 OTHER PRODUCT RANGES SERVICE INDEX Lever Handles Escutcheons & Bathroom Turns Academy Range Pull Handles Push Plates & Kick Plates Signage Lockcases Cylinders Door Controls Hinges

More information

CLEAR GLASS WALL SYSTEMS

CLEAR GLASS WALL SYSTEMS CLEAR GLASS WALL SYSTEMS SERIES SI3000C Clean, uninterrupted views. Series SI3000C Clear Glass Walls create a seamless wall with uninhibited views. Clear Glass Walls eliminate vertical stiles, allowing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20 Flat Goods Section TABLE OF CONTENTS EXIT DEVICES PUSH BAR EXIT DEVICES N1500 Heavy Duty Rim Exit Device N1550 Rim Exit Device... 6 N1650 Fire Rated Heavy Duty Exit Device N1700(F) Vertical Rod Heavy Duty

More information

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware Recommendations for Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware By Keith E. Pardoe Speed, accuracy, and above all consistency are essential when determining the clearance

More information

Series 626 FrontGLAZE Framing

Series 626 FrontGLAZE Framing Double Glazed 150mm COMMERCIAL FRAMING Charles Sturt University Learning Commons Building. Architect: JWP (Jovaras Westland Partnership). Windows by DLG Aluminium & Glazing. DATE: MAY 2013 REPLACES: MARCH

More information

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS These requirements apply to all fire rated doors, frames, and windows. Requirements for the installation of these assemblies are included in the Standard

More information

Assembly Instructions 10 X 10 Aluminum Frame Building

Assembly Instructions 10 X 10 Aluminum Frame Building Assembly Instructions 10 X 10 Aluminum Frame Building 27 97 9 8 47 36 74 52 10 10 X 10 Square Building W/ Dome Includes: The Steel Entry Door with a Dead Bolt Lock assembly and Aluminum Door Frame. Metal

More information

KEY FEATURES HARDWARE ICON BI-FOLD OPERATOR

KEY FEATURES HARDWARE ICON BI-FOLD OPERATOR ICON BI-FOLD OPERATOR This swivel bi-fold operator throws locking bolts into the frame at top and bottom of the panel. Optional key-locking (separately installed) is available. Having an operator handle

More information

CLEAR GLASS WALL SYSTEMS

CLEAR GLASS WALL SYSTEMS PRODUCT DATA SHEET SERIES SI3000C CLEAR GLASS WALL SYSTEMS Clean, Uninterrupted Views Series SI3000C Clear Glass Walls eliminate vertical stiles, allowing for maximum transparency, natural daylighting,

More information

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS 1200 SERIES 2 PANEL DOOR 10.2013 rev.1 DETAILED INSTALLATION INTRUCTIONS GENERAL: Door elevations shown in these instructions are as viewed from the outside. X denotes the active or moving panel(s). O

More information

CGI Series 560 SGD Installation Instructions

CGI Series 560 SGD Installation Instructions CGI Series 560 SGD Installation Instructions Read these instructions completely before beginning to install. Become familiar with what type of installation will be required. This door can be installed

More information

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT 821 811 342 821 835 853 863 840 12.5mm Plasterboard 837 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims Note: For clarity the cavity infill has not been shown 854 342

More information

Kestrel Aluminium Systems Limited. Product Manual Section 13 60mm Polyamide Window System - Fabrication. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 13 60mm Polyamide Window System - Fabrication. Manual Version Limited Product Manual Section 13 60mm - Fabrication Manual Version 24.0.1 Section 13.01 Fabrication Guidelines for cutting and prepping 13.01.01 sheet 1 General guidelines for cutting and bar preparation

More information

CONTENTS. Custom Entrances and Hardware

CONTENTS. Custom Entrances and Hardware CONTENTS A2/1 CONTENTS SECTION A2...CUSTOM ENTRANCES AND HARDWARE* PAGE PRICING EXAMPLES... A2/3 A2/4 190/350/500 BASE DOOR DOOR CHASSIS... A2/5 DOOR GLAZING/WEATHERING OPTIONS... A2/6 DOOR BOTTOM RAIL

More information

(Non Handed Kits) Slotted Hand Screwdriver. Power Driver & Bits. Work Gloves

(Non Handed Kits) Slotted Hand Screwdriver. Power Driver & Bits. Work Gloves Patio Door Kit Assembly Instructions -- 2-Panel Patio Door with Non-Assembled Frame and Assembled Sash Panels. (Non Handed Kits) Project Requirements: ~ This door was manufactured for installation into

More information

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY. SARGENT Installation Instructions for LP8600 x LR8600 & 12-LP8600 x 12-LR8600 Series Low Profile Panic and Fire Exit Devices on Double Egress & Double Doors or LS8600 & 12-LS8600 Low Profile Exit Device

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE

SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE SMART SYSTEMS VISOGLIDE+ INSTALLTION GUIDE Please read guide before beginning any installation. Instructions/Guides Keys & Handle Screw Covers Interlock Covers Anti-Lift & Rubber Stops Anti-Lift for Slim

More information

8' Multi-Purpose Easi-Frame Assembly Instructions

8' Multi-Purpose Easi-Frame Assembly Instructions 1 8' Multi-Purpose asi-frame ssembly Instructions Using this frame with: n XL Joinery door pair (using hinges) with either fixed or hinged asi-frame side panels or emi Panels on either side asi-frame Panels

More information

SPW600e Inward Opening SPW600. Product Assembly Manual 2012 Inward Opening

SPW600e Inward Opening SPW600. Product Assembly Manual 2012 Inward Opening SPW600e Inward Opening SPW600 Product Assembly Manual 2012 Inward Opening SPW600e.2.ii 04.12 SPW600e Inward Opening Introduction The Company Senior Architectural Systems are a group of companies based

More information

5' Multi-Purpose Easi-Frame Assembly Instructions

5' Multi-Purpose Easi-Frame Assembly Instructions 1 5' Multi-Purpose asi-frame ssembly Instructions Using this frame with: n XL Joinery door pair (using hinges) with either a fixed or hinged asi-frame emi Panel XL Panels used as a i-fold with a fixed

More information

PVCu FOLD & SLIDE DOOR OUTWARD OPENING

PVCu FOLD & SLIDE DOOR OUTWARD OPENING PVCu FOLD & SLIDE DOOR OUTWARD OPENING STEP-BY-STEP FULLY ILLUSTRATED ASSEMBLY INSTRUCTIONS This product is covered by a 10 year manufacturer s guarantee. Should any part of it become defective due to

More information