Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

Size: px
Start display at page:

Download "Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄"

Transcription

1 SU Series: DIN Rail Snap-Mount SU Series: DIN Rail Snap-Mount SUS-L SUS-L -blade DIN-mount/surface mount -blade DIN-mount/surface mount Spring clamp terminals Spring clamp terminals - AWG - AWG 0A A (using RU), 0A (using RU) RU, RM RYS, RYS, RU, RUS, RYKS, RMS GTY- GTY SA-0 (top latch), SA-0 (side latch) SA-0 (top latch), SA-0 (side latch). On the SUS, wires or ferrules cannot be connected to terminals,,,, 0 or because neither springs nor conductive brackets are installed in these terminals.. or socket mounting accessories, see page -. Inside the Cable Ports Inside the Cable Ports (top view) SUS-L SUS-L Dimensions Center of Relay-mounting area Parts Wire Ports C Wire Ports NO Wire Ports NC ➃ Screwdriver Ports ➀ ➁ ➄ ➅ ➂ Wire Ports Coil Marking Plate Clamp Spring slots for SA-0: ➀➁➄➅ Spring slots for SA-0:.. ➁➂➃➄. Panel Cutout for Surface Mounting - USA: (00) -IDEC or (0) -00, Canada: () -IDEC

2 SU Series: DIN Rail Snap-Mount SU Series: General Instructions Applicable Wires Wire Size Stranded wire 0. to. mm or AWG to Wiring Instructions Wire Port A Wire Ports for Wire Ports for 0 Solid wire 0. to. mm or AWG to Wire insulation diameter ø.mm maximum. Strip the wire insulation to 0mm from the end.. In applications using ferrules for stranded wires, choose the ferrule listed in table below. Make sure that an insulation sheath is applied when using the ferrules. When using stranded wires without ferrules, make sure that the core wires have not been loosened.. Two cable ports are provided for each terminal. Applicable errules Applicable Wire (stranded) mm AWG Type Manufacturer 0. A0.-BU Phoenix Contact _ A0.-TQ Phoenix Contact 0. 0 to 0mm A0.-WH A0.-0WH TE0. Phoenix Contact Nichifu Co. Ltd Stopper A - B sec Screwdriver Ports. Insert the optional screwdriver (BCS-SDO) or an applicable screwdriver into the squareshaped port as shown on the right, until the screwdriver tip touches the bottom of the spring.. Push in the screwdriver until it touches the bottom of the port. The wire port is now open, and the screwdriver is held in place. The screwdriver will not come off even if you release your hand.. While the screwdriver is retained in the port, insert the wire or ferrule into the round-shaped wire port. Each wire port can accommodate one wire or ferrule. When connecting two wires to one terminal, use the adjoining port of the same terminal.. Pull out the screwdriver. The connection is now complete. Correct Incorrect B Incorrect Incorrect Direction of Screwdriver Tip Note: Two cable ports are provided for each terminal. or wiring, use the optional screwdriver (BCS-SDO) or the following applicable screwdriver.. 0. (Dimensions in mm) to º ø. Safety Precautions Installing the Marking Plate Because of its removable structure, the marking plate may have fallen from the socket or become loose in delivery. Make sure that the marking plate is securely installed before starting operation. The marking plate protects the conductive portion of the socket, located under the marking plate, by preventing metal fragments or pieces of wire from dropping inside. Should any such fragments enter the socket, they may cause fire hazard, damage, or malfunction. Jumper Ports Marking Plate Marking Instructions Write markings on the SU sockets using an oil-based marker, or glue printed mylar on the marking surface. The size of the printed mylar can be x mm maximum. Marking Surface.0.0 No marking plate Loose fitting Note: or installation of optional jumper, see the instruction sheet provided with the jumper. Installed securely plate ribs (on both sides) r Jumper.0 Inserting Screwdriver into the Wire Ports Marking Plate Maximum size of printed mylar Position of printed mylar on the marking surface USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

3 SU Series: DIN Rail Snap-Mount SU Series: SUZ-J Jumper Installation Instructions SUZ-J Jumper for SUS-L and SUS-L The SUZ-J is used to install five sockets. When installing less than five sockets cut the jumper according to the instructions listed to the right. The SUZ-J jumper is for coil terminals only. SUZ- Jumper Rated Current A Conductor Nickel-plated brass Material Sheath ABS resin Installation Loosen the marking plate on the socket. Installing Two, Three or our SU on the SUZ-J Jumper As shown below, slide the jumper in the sheath so that the jumper aligns with the center of the sheath. Jumper off center With the sheath properly installed on the jumper, cut the sheath and jumper at the points shown below, using cutting pliers. Referring to the drawing on the right, make sure that the sheath and jumper are cut within the cutting area. Dispose of unused portions according to local waste disposal requirements. X Y Z Jumper on center Shea Jump Shea Cutting Area C Cutting Area D A: Loose fitting B: Installed securely A B C D Cutting Area in Detail Qty Cutting Area Discard A, C Y Ribs A, B X D Z After cutting the jumper and sheath, slide the jumper as shown below, so that the ends of the jumper ar e not exposed. Grooves for marking plate ribs (on both sides) Alignment Making sure that the SUZ-J jumper is correctly aligned, insert the blades into the ports in the groove of the SU sockets. Incorrect Correct Jumper Wiring to Six or More SU To jumper wire six or more SU sockets, connect five sockets using whole jumpers and the remaining sockets using a cut jumper. Then connect the two terminals on adjoining sockets using an applicable wire (see table below). Proper wire Insertion Direction Jumper port for terminal Jumper port for terminal Blade Wire Stranded wire 0. to. mm Solid wire 0. to. mm Size AWG to Jumper Groove Jumper Install Jumper Securely Press down the marking plate to secure the jumper. The jumper installation is now complete.. Use a wire with cable insulation diameter of ø.mm maximum.. Strip the cable insulation to 0mm from the end. Safety Precautions Turn off the power to the SUZ-J jumper before starting installation, removal, wiring, maintenance, or inspection of the jumper. ailure to turn power off may cause an electrical shock or fire hazard. To avoid a short circuit due to incorrect wiring, confirm which terminals are connected to the jumper before beginning wiring. - USA: (00) -IDEC or (0) -00, Canada: () -IDEC

4 SJ Series: DIN Rail Snap-Mount SJ Series: General Information SJS-0B Replacement Locking Lever -blade snap mount/surface mount N m (Maximum.N m) Maximum up to - # AWG 0V, A RJS N/A N/A SJZ-C SJS-0L ingersafe Replacement Locking Lever -blade, snap mount/surface mount N m (Maximum.N m) Maximum up to - # AWG 0V, A RJS N/A N/A SJZ-C SJS-0B Replacement Locking Lever -blade, snap mount/surface mount N m (Maximum.N m) Maximum up to - # AWG 0V, A RJS N/A N/A SJZ-C USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

5 SJ/SQ Series: DIN Rail Snap-Mount SJS-0L ingersafe Replacement Locking Lever -blade snap mount/surface mount N m (Maximum.N m) Maximum up to - # AWG 0V, A RJS N/A N/A SJZ-C SQ Series: General Information SQV-0B ingersafe Replacement Locking Lever Replacement Marking Plate Plug-in LED/Diode (-VDC) Plug-in LED/RC (0/0VAC) -pin, snap mount/surface mount.0n m Maximum Maximum up to - # AWG 00V, A RQV-CM SQZ-C SQZ-P SQZ-LD SQZ-LR SQV-0B ingersafe Replacement Locking Lever Replacement Marking Plate Plug-in LED/Diode (-VDC) Plug-in LED/RC (0/0VAC) -pin, snap mount/surface mount.0n m Maximum Maximum up to - # AWG 00V, A RQV, RQV-CH SQZ-C SQZ-P SQZ-LD SQZ-LR -0 USA: (00) -IDEC or (0) -00, Canada: () -IDEC

6 SR Series: DIN Rail Snap-Mount SR Series: DIN Rail Snap-Mount SRP SRP-0 -pin octal, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) Maximum up to #AWG 00V, 0A RRP RTE-P, GT (-pin), GTP, GEA SRB-0 (for RRP) SA-0 (for timers only, except GEA) M. Screw ø ø. Mounting Hole when. 0..max..max. ø.min. min. SRP-0C ingersafe -pin octal, snap-mount/surface mount M. screws with captive wire clamp, fingersafe ( -. in lbs) Maximum up to #AWG 00V, 0A RRP RTE-P, GT (-pin), GTP, GEA SRB-0 (for RRP) SA-0 (for timers only, except GEA)... when. 0 (cannot use ring terminal) SRP-0 -pin octal, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) 0 M. Screw. when Maximum up to #AWG 00V, 0A RRP RTE-P, GT (-pin), GTP, GEA SRB-0 (for RRP) 0 ø ø. Mounting Hole.max..max. min. ø.min. SA-0 (for timers only, except GEA). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page -. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

7 SR Series: DIN Rail Snap-Mount SRP SRP-0 -pin octal, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) M. Screw when Maximum up to #AWG 00V, 0A RRPA, RRKP GT (-pin), RTE-P SRB-0 for RRP; SRP-0 for RRKP ø ø. Mounting Hole. 0..max..max. min. ø.min. 0 SA-0 (Timers) SRP-0C ingersafe -pin octal, snap-mount/surface mount M. screws with captive wire clamp, fingersafe ( -. in lbs) Maximum up to #AWG 00V, 0A RRPA, *RRKP (*latching relay) GT (-pin), RTE-P SRB-0 for RRPA; SRP-0 for RRKP SA-0 (Timers). 0 ø ø.. when. 0 (cannot use ring terminal) 0 SRP-0 -pin octal, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) Maximum up to #AWG M. Screw. when 00V, 0A RRPA, *RRKP (*latching relay) GT (-pin), RTE-P SRB-0 for RRPA; SRP-0 for RRKP 0 ø ø. Mounting Hole.max..max. min. ø.min. 0 SA-0 (Timers). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page USA: (00) -IDEC or (0) -00, Canada: () -IDEC

8 SR Series: DIN Rail Snap-Mount SRB SRB-0 -blade, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) M. Screw. When using BAA/BAP:. DIN Rail (BAA/BAP) s (or M Tapped Holes). max.. min. B A (Top View) Maximum up to #AWG 00V, A (0A)* (*denotes CSA rating).. max. ø. min. RRBA, RRBA, RRB RTE-B SRB-0 (relays) SA-0 (relays and timers). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page -. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

9 SH Series: DIN Rail Snap-Mount SH Series: DIN Rail Snap-Mount SHB SHB-0 -blade, snap-mount/surface mount. M. Screw When using BAA/BAP:. DIN Rail (BAA/BAP) s (or M Tapped Holes) (Coil) M screws/(. - in lbs) (contact) M. screws ( -. in lbs) with captive wire clamp Maximum up to #AWG 0V, 0A RHB SYS-0 SA-0 (top notch), SA-0 (side notch). 0 M Screw.. max.. max.. min. (or terminals,, and ) ø. min. max.. max.. min. (or terminals and ) (Top View) ø. min. SHB-0C ingersafe -blade, snap-mount/surface mount (Coil) M screws/(. - in lbs) (contact) M. screws with captive wire clamp, fingersafe ( -. in lbs) Maximum up to #AWG 0V, 0A RHB. 0 M. Screw ø. M Screw When using BAA/BAP:.. DIN Rail (BAA/BAP) s (or M Tapped Holes) Ring type crimping terminals cannot be used. (Top View) SYS-0 SA-0 (top notch), SA-0 (side notch). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page USA: (00) -IDEC or (0) -00, Canada: () -IDEC

10 SH Series: DIN Rail Snap-Mount SHB SHB-0 -blade, snap-mount/surface mount. M. Screw When using BAA/BAP:. DIN Rail (BAA/BAP) s (or M Tapped Holes) M. screws with captive wire clamp ( -. in lbs) Maximum up to #AWG 00V, 0A RHB. 0.. max.. max.. min. ø. min. (Top View) SYS-0 SA-0 (top notch), SA-0 (side notch) SHB-0C ingersafe -blade, snap-mount/surface mount M. screws with captive wire clamp, fingersafe ( -. in lbs) M. Screw ø. When using BAA/BAP: DIN Rail (BAA/BAP) s (or M Tapped Holes) Maximum up to #AWG 00V, 0A RHB SYS-0 SA-0 (top notch), SA-0 (side notch). 0.. Ring type crimping terminals cannot be used. (Top View). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page -. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

11 A 0 A SH Series: DIN Rail Snap-Mount SHB SHB-0 -blade, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs) Maximum up to #AWG. M. Screw. when 00V, 0A RHB, RHLB SHB-0 SA-0 (top notch), SA-0 (side notch). 0..max..max..min. ø.min. 0 SHB-0C ingersafe -blade, snap-mount/surface mount M. screws with captive wire clamp, fingersafe ( -. in lbs) Maximum up to #AWG 00V, 0A RHB, RHLB SHB-0 SA-0 (top notch), SA-0 (side notch). 0 M. Screw ø. when.. (cannot use ring terminal) 0. or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page USA: (00) -IDEC or (0) -00, Canada: () -IDEC

12 SH Series: DIN Rail Snap-Mount SHB SHB-0 -blade, snap-mount/surface mount M. screws with captive wire clamp ( -. in lbs). M. Screw. when Maximum up to #AWG 00V, 0A RHB SHB max..max..min. ø.min. 0 SA-0 (top notch), SA-0 (side notch) SHB-0C ingersafe -blade, snap-mount/surface mount when M. screws with captive wire clamp, fingersafe ( -. in lbs) Maximum up to #AWG 00V, 0A RHB SHB-0 SA-0 (top notch), SA-0 (side notch). A 0 0 A ø... (cannot use ring terminal) 0. or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page -. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

13 A A SY Series: DIN Rail Snap-Mount SY Series: DIN Rail Snap-Mount SYS SYS-0 -blade, snap-mount/surface mount M screws with captive wire clamp (. - in lbs) Maximum up to #AWG 00V, A RYS, RYS SYS-0 SA-0 (top notch), SA-0 (side notch) 0. M Screw. when. max..max..min. ø.min. SYS-0C ingersafe -blade, snap-mount/surface mount M screws with captive wire clamp, fingersafe (. - in lbs) Maximum up to #AWG 00V, A RYS, RYS SYS-0 SA-0 (top notch), SA-0 (side notch).. 0 M Screw ø.. when. (cannot use ring terminal). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page USA: (00) -IDEC or (0) -00, Canada: () -IDEC

14 SY Series: DIN Rail Snap-Mount SYS SYS-0 -blade, snap-mount/surface mount M screw with captive wire clamp (. - in lbs) Maximum up to #AWG 00V, A RYS, RYS, RUS, RUS, RMS, *RYKS, (*latching relay) GTY SYS- for all relays; SYS- for RYKS only SA-0 (top notch), SA-0 (side notch) for all relays and timers M Screw. when. max..max..min. ø.min. 0 SYS-0C ingersafe -blade, snap-mount/surface mount M screw with captive wire clamp, fingersafe (. - in lbs) Maximum up to #AWG 00V, A 0 M Screw ø.. when RYS, RYS, RMS, RUS, RUS, *RYKS, (*latching relay). GTY SYS- for all relays; SYS- for RYKS only SA-0 (top notch), SA-0 (side notch) for GTY timer and relays. A 0 A.0. (cannot use ring terminal) 0. or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page -. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

15 A 0 A SM Series: DIN Rail Snap-Mount SMS SMS-0 -blade, snap-mount/surface mount M screw with captive wire clamp (. - in lbs) Maximum up to #AWG 00V, 0A RUS, RMS SYS- SA-0 (top notch), SA-0 (side notch) M Screw. when. max..max..min. ø.min. SMS-0C ingersafe -blade, snap-mount/surface mount M screw with captive wire clamp, fingersafe (. - in lbs) Maximum up to #AWG 0 M Screw ø.. when 00V, 0A RUS, RMS SYS- SA-0 (top notch), SA-0 (side notch)... (cannot use ring terminal). or socket mounting accessories, see page -.. or hold-down clip/spring selections, see page USA: (00) -IDEC or (0) -00, Canada: () -IDEC

16 Accessories Accessories SA-0 SA-0 SA-0 mm mm M screw washer hold-down spring Description Appearance Use with Part No. Remarks Aluminum DIN Rail ( meter length) All DIN rail sockets BNDN000 IDEC offers a low-profile DIN rail (BNDN000). The BNDN000 is designed to accommodate snapmount sockets. Made of durable extruded aluminum, the BNDN-000 measures 0. in height and. (mm) in width (DIN standard). Standard length is " (,000mm). DIN Rail End Stop DIN rail BNL. mm wide. Surface Mount End Connector SYS, SYS, SRB, SHB, SHB, SHB, SHB SA-0 SA-0 or use on ends of socket groupings when surface mounting. or use between adjoining sockets when surface mounting. Surface Mount Connector SYS, SYS, SRB, SHB, SHB, SHB, SHB SA-0 or use between adjoining sockets when surface mounting. DIN Rail Spacer All DIN rail sockets SA-0 Steel Mounting Plates (for panel mount sockets) SYS-, SHB- SA-0." length with 0 holes. SYS-, SHB- SA-0." length with holes. Relay Holders RHB, RMS, RYS, RYS, RUS, RUS RYS, RHB RH-0 RH-0 or diagram, see next page. Replacement Hold- Down Spring Anchor Horseshoe clip for all DIN rail sockets except SR*P-0(C) Y-0 or use with hold-down springs (bale wire types). or DIN rail mount sockets. pieces included with each socket. for SR*P-0(C) Chair clip for SR*P-0(C) Y0-0 or SRP-0, SRP-0C, SRP-0, SRP-0C USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

17 Instructions Instructions Mounting Snap-Mount Snap-mount sockets are designed to mount on the BNDN-000 Mount mounting rail. The built-in mounting clip eliminates mounting hardware and reduces mounting time by 0%. To mount see igure. Place the end of the socket (end opposite of mounting clip against the outer edge of the rail). Press the socket down firmly until the clip snaps onto the mounting rail. To remove igure see igure. Pull out the mounting clip with a screwdriver, and lift the socket. Remove or spacing between adjoining sockets, use the SA-0 DIN rail spacer. Spacers are 0." wide. Spacing can be adjusted according to the number of spacers added. Spacers snap on and off easily like snap-mount sockets. igure To prevent side-to-side movement, use a BNL- end clip at each end of every socket row. Mounting Relay Holders RH-0 or -0 Mount directly onto panel boards in two alternate positions: A and B (see igure ). igure To mount the relay into the holder, hook the bottom edge of the relay case (coil terminal side) onto the relay holder (see igure ). Push down until the relay snaps into place. igure Mounting s Take the two anchor clips (horseshoe / U-shaped piece) that come with the socket and insert into the slits on both sides of the socket. Make sure the raised notches on the anchor clip face into the socket. Plug relay into socket Insert the open ends of the hold-down spring into either the first or second hole of the anchor clip. The relay-spring combination will determine which hole should be used. Slide spring over relay USA: (00) -IDEC or (0) -00, Canada: () -IDEC

18 Dimensions Dimensions Surface Mount (SHB-0) IDEC surface mount sockets (SHB-0) are also designed to mount individually or collectively on a flat surface without the use of a DIN rail. Use the mounting screw between adjoining sockets and at the outer ends of the row of sockets. Dimension Table Socket Part No. Dimension A SHB-0." A A A. Drawing is not to scale. Snap-Mount Snap-mount sockets are designed to mount individually or collectively without using a rail. Use a SA-0 connector or SA-0 connector between adjoining sockets (see igures and ). Use the SA-0 end connector at the outer ends of each socket row when using the SA-0 connector (see igure ). Dimension Table Socket Part No. Dim. B Dim. C Dim. D SYS-0, SYS-0C 0." 0." 0." SYS-0, SYS-0C.0".".0" SRB-0."."." SHB-0, SHB-0C 0.0" 0." 0." SHB-0, SHB-0C.0".".0" SHB-0, SHB-0C."."." SHB-0, SHB-0C.".".00" Using an SA-0 Connector B C C C Using SA-0 or SA-0 Connectors C 0." Hole or M Tapped D D D. Drawings are not to scale. USA: (00) -IDEC or (0) -00, Canada: () -IDEC -

19 Dimensions Dimensions, continued Collective Panel Mounting SYS- SH and SY series panel mount sockets are designed to mount collectively in panel cut-outs. Insert socket with mounting springs facing the top and bottom edge of the panel cut-out. Push the socket until the mounting spring clips onto the panel. (See igure.) Dimension Table Part No. Width Relay igure SYS-.0" RYS, RY, RYKS, RMS SHB-." RHB RHB RMS RHB RYKS SHB-." RHB, RHLB SHB-.0" RHB SHB- 0.0" RHB SYS- 0.0" RYS, RYS How to Calculate Cutout Length (L) Cutout L = A (Total Overall Width of Each Socket) 0." (+ 0", 0.00") Example: A = Total Overall Width of Each Socket Cutout L = A 0." (+ 0", 0.00") SYS- SYS- SYS- SHB- SYS- SYS- SHB- SHB- L = [0.0" +.0" +.0" + 0.0" +.0" + 0.0" +.0" +.0"] 0." =." SYS- L =." (+ 0", 0.00") Mounting Plate - USA: (00) -IDEC or (0) -00, Canada: () -IDEC

SH Series: DIN Rail Snap-Mount Sockets. SH1B Sockets " (17mm) 0.172" (4.4mm) 0.216" (5.5mm) Ø 0.140" (3.6mm) 2.613" (67mm) 2.

SH Series: DIN Rail Snap-Mount Sockets. SH1B Sockets  (17mm) 0.172 (4.4mm) 0.216 (5.5mm) Ø 0.140 (3.6mm) 2.613 (67mm) 2. SHB SHB-05 5-blade, snap-mount/surface mount (Coil) M3 screws/(contact) M3.5 screws with captive wire clamp 250V, 0A RHB SY2S-02 0.3" (4.4mm) 0.26" (5.5mm) 0.663" (7mm) 2.63" (6mm) 0.780" (20mm) 4 5 9

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls. Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Relays. Switching & Controls. Selection Guide

Relays. Switching & Controls.   Selection Guide Switching & Controls Selection Guide... 7 General Purpose Relays... 7 RVH Series mm Interface Relays... 7 RJ Series Slim Power Relays... 7 RQ Series PCB Relays... 7 RH Series Compact Power Relays... 77

More information

This document provided by Barr-Thorp Electric Co., Inc

This document provided by Barr-Thorp Electric Co., Inc Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Relays. Switching & Controls. Selection Guide

Relays. Switching & Controls.   Selection Guide Switching & Controls Selection Guide... 7 General Purpose Relays... RVH Series 6mm Interface Relays... RVS Series 6mm Interface Relays... RJ Series Slim Power Relays... RQ Series PCB Relays... 3 RH Series

More information

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls. Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications

More information

RJ Series Slim Power Relays

RJ Series Slim Power Relays RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.

More information

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact

More information

Relays. Switching & Controls.

Relays. Switching & Controls. Switching & Controls Selection Guide... 0 General Purpose Relays... RVH Series mm Interface Relays... RVS Series mm Interface Relays... RVH Series mm Interface Relays... RJ Series Slim Power Relays...

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION P 1 / 11 Model No. Description CONCEPT AND MAIN APPLICATIONS Specification Standard equipment TCT saw blade... 1 Rear table set (exclusively Europe, Turkey, South Africa..1 2704 This

More information

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814 TW Series Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA, 00-70 Main Office: (50) 5-00 Outside Local Area: (00) 5-00 www.steveneng.com Specifications Time Range Rated Voltage

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive RFV RFV -Pole Force Guided Relays/SJ Series Relay Sockets Key features: -pole force guided relay to reduce cost and installation space. Force guided contact mechanism (EN00 Type A TÜV approved). Reinforced

More information

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH Thank you for choosing the Mitsubishi vector inverter option unit. This instruction manual gives handling information and precautions for

More information

Interactive Monitor Arm

Interactive Monitor Arm Interactive Monitor Arm Tools Required -5mm Allen wrench -Phillips screwdriver -Plastic mallet There are two ways to attach a Monitor Arm to a Full Frame; with a Beam, or with a Post Mount. Both methods

More information

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING INVERTER Plug-in option FR-A7AX INSTRUCTION MANUAL 16 bit digital input function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING CONNECTION DIAGRAM AND TERMINAL PARAMETERS 1 2 3 4 Thank you for choosing

More information

Timers GE1A. GE1A Series ON Delay Timers Single Function

Timers GE1A. GE1A Series ON Delay Timers Single Function Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators

More information

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems FABA Conductor Bar System Installation Instructions Publication #FABA-03 3/1/04 Part Number: 005-1062 Copyright 2004 Electromotive Systems 1S 100 Z Installation Instructions Contents: Basic Diagram - -

More information

Assembly and Installation Guide

Assembly and Installation Guide The Easy Hang Closet Solution SM Install Your elfa In An Instant. Enjoy The Benefits For A Lifetime. Basic Tools For elfa Assembly and Installation Level Hand or Power Drill Drill Bits 1/8", 3/8", 5/16"

More information

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE T F W 604.549.979 604.549.9555 fluxwerx.com INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE fixture housing endcap kit optic kit join kit notch 2 cross section notch 4 cross section 4 4" 4-11/2" 4 /8 (111)

More information

3.2.3 Rear Door Window and Quarter Window Carrier Assembly

3.2.3 Rear Door Window and Quarter Window Carrier Assembly Tighten all bolts. Tighten bolts marked -1- and -2- in specified sequence. Tightening torque: 8 Nm Remaining bolts can be tightened in any sequence. Insert door window -3- through window recess without

More information

Figure A. Figure B. Figure C. Figure D

Figure A. Figure B. Figure C. Figure D Xsite 1 Power/Data Tile and Components Tools Required Tape Measure Cordless Drill/Driver #2 Phillips Screw driver bit Rubber Mallet Flat Blade Screwdriver Figure A Hardware Required Provided as shown Installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information on last page. Review

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

MOVENTO. The Evolution of Motion

MOVENTO. The Evolution of Motion The Evolution of Motion is the latest advancement in concealed runner technology. It brings together all of the features, innovations and benefits that Blum has developed since first manufacturing drawer

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

Relays & Sockets. General-purpose electromechanical relays and sockets

Relays & Sockets. General-purpose electromechanical relays and sockets Relays & Sockets General-purpose electromechanical relays and sockets Relays (Selection Guide) Category Slim Power Relay Model RJ RJ PC Board Terminal General SPDT, DPDT: A or A contact RoHS directive

More information

ABM International, Inc.

ABM International, Inc. ABM International, Inc. Lightning Stitch required 1 1.0: Parts List head and motor assembly (Qty. 1) Reel stand (Qty. 1) Needle bar frame clamp (Qty. 1) Motor drive (Qty. 1) 2 Cable harness with bracket

More information

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.

More information

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index: Installation Instructions ININST.1001 1790 Touchbar Rim Panic Device Index: Before Installation... 2 Installation... 2 Touchbar Dogging... 7 RM170 Mullion Installation... 8 Field Sizing Device... 10 2090

More information

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11 Mighty Mo GX Series Cabinet Installation Guide OR-71601787 Safety and Warning ATTENTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating

More information

FlexFrame - Storage Components and Skins

FlexFrame - Storage Components and Skins FlexFrame - Storage Components and Skins 1/4 Square Drive Ball-Point Hex-Bit Socket 1/8 Short Hex, 1-1/2 Overall Length McMaster Part # 54075A44 Table of Contents Topic Page Storage Components 2 General

More information

Installing flat panels on the MPL15 wall mount

Installing flat panels on the MPL15 wall mount Installing flat panels on the MPL15 wall mount The MPL15 (DS-VW775) is a full-service video wall mount that can accommodate tiled LCD panels with up to a 400 x 400 mm VESA pattern in portrait and landscape

More information

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.

More information

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment. 2005-08 Pontiac G6 GT Please read BOTH these and the General Towing Instructions before attempting to install or operate this equipment. 1. Blue Ox towing products and accessories are intended to be installed

More information

Laminate Cabinet Installation Instructions

Laminate Cabinet Installation Instructions Laminate Cabinet Installation Instructions www.easygaragestorage.com/installation How To Use These Instructions Thank you for your purchase! Please read each step of this manual thoroughly to ensure proper

More information

TRAKFAST REPAIR MANUAL DANGER TOOL DISASSEMBLY ALWAYS TAKE THE FOLLOWING PRECAUTIONS BEFORE ANY SERVICE OR ROUTING MAINTENANCE IS PERFORMED:

TRAKFAST REPAIR MANUAL DANGER TOOL DISASSEMBLY ALWAYS TAKE THE FOLLOWING PRECAUTIONS BEFORE ANY SERVICE OR ROUTING MAINTENANCE IS PERFORMED: DANGER ALWAYS TAKE THE FOLLOWING PRECAUTIONS BEFORE ANY SERVICE OR ROUTING MAINTENANCE IS PERFORMED: REMOVE FASTENERS REMOVE FUEL CELL REMOVE BATTERY REMOVE THE MAGAZINE ASSEMBLY Loosen and remove knob

More information

Palm-sized, 16-channel Relay Terminals

Palm-sized, 16-channel Relay Terminals Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive

More information

TECHNICAL INFORMATION Models No. Description

TECHNICAL INFORMATION Models No. Description TECHNICAL INFORMATION Models No. Description KP0810, KP0810C Power Planer 82mm (3-1/4") W PRODUCT P 1 /11 CONCEPT AND MAIN APPLICATIONS Model KP0810 features the following user-friendly advantages: *Left

More information

ROMAN AND. Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION INSIDE MOUNT. A few simple tools are required:

ROMAN AND. Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION INSIDE MOUNT. A few simple tools are required: ROMAN AND WOVEN WOOD SHADES Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION A few simple tools are required: The brackets you received with your product are REQUIRED for proper

More information

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions All clutch operated shades are shipped fully assembled and ready for installation. Mounting screws are not provided. Screws for chain guide installation to meet the child safety standards are provided.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Video Wall Installation Instructions 2W X 3H, 3W X 3H Video Wall Installation Instructions 2W X 3H, 3W X 3H www.microndisplaysolutions.com Table of Contents Important Safety Instructions... 3 Configuration... 4 Package Contents, included and optional items...

More information

Mechanical Frappe Press

Mechanical Frappe Press Mechanical Frappe Press Operation Manual CONTENTS OPERATIONAL INSTRUCTIONS PRECAUTIONS PART NAMES INCLUDED ITEMS BASIC OPERATION MAINTENANCE REPLACEMENT PARTS Thank you for using The Frapptastic Five Mechanical

More information

Footprint Mobile Assembly Instructions

Footprint Mobile Assembly Instructions Footprint Mobile Assembly Instructions 1998754 Revision -1 Complete Series Master Packet If you have any questions concerning these instructions, please call Kimball Office Customer Service. 20 Kimball

More information

Move System Swivel Caster Installation ( )

Move System Swivel Caster Installation ( ) Move System Swivel Caster Installation (002-10265-00) Caution Always disconnect power to chair before removing covers or performing any service procedures. Step 1: Remove Top Cover A) Position chair to

More information

WINSTA The Connection System. Full Line Catalog 2010/2011

WINSTA The Connection System. Full Line Catalog 2010/2011 WINSTA The Connection System Full Line Catalog 2010/2011 5 WAGO Registered Trademarks CAGE CLAMP CAGE CLAMP @ POWER CAGE CLAMP FIT CLAMP PUSH WIRE TOPJOB TOPJOB @ WINSTA WAGO X-COM X-COM @ JUMPFLEX TO-PASS

More information

711 Series Single Way DB-1a

711 Series Single Way DB-1a 711 Series Single Way DB-1a Data Bus Interconnection System Data Bus Interconnection System designed for data transmission as defined by MIL-STD-1553B, STANAG 3838 and DEF STAN 00-18 (Part 2). This system

More information

INSTALLATION MANUAL H A

INSTALLATION MANUAL H A INSTALLATION MANUAL CABINET RACK CR-43-6 (4-UNIT SIZE) Be sure to read this installation manual thoroughly before installing this Cabinet Rack. For the mounting procedures of the components and the relevant

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 114-16016 17 APR 14 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Unless

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable

More information

Privacy Wall Glass Selections - Polished Edge Slider Door

Privacy Wall Glass Selections - Polished Edge Slider Door Privacy Wall Glass Selections - Polished Edge Slider Door 3/6" HEX BIT PUTTY KNIFE #2 ACR BIT SUCTION CUP HOLDERS DOOR LEAF: Satin Tempered Clear Tempered LOCTITE 425 SIDE LIGHT ETCHED GLASS STYLES: Satin

More information

Code Product Qty 1 Top Vertex 3 2 Hot End Housing 1 3 Bottom Vertex 3 4 Print Platform Lock 3 5 End Stop Holder 3 6 Filament Feeder Motor Bracket 1 7

Code Product Qty 1 Top Vertex 3 2 Hot End Housing 1 3 Bottom Vertex 3 4 Print Platform Lock 3 5 End Stop Holder 3 6 Filament Feeder Motor Bracket 1 7 List of Parts Code Product Qty 1 680mm Extrusion 3 2 Power Supply 1 3 240mm Extrusion 9 4 42mm Nema 17 Stepper Motor 3 5 Slider-Hotend Connecting Rod 6 6 48mm Nema 17 Stepper Motor 1 7 Linear Rail with

More information

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header Pluggable PCB terminals and headers Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header System features plug in system is simple

More information

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JULY 2003 RM3010A RM315-R2 RM323-R2 RM329 RM451 RM457 RM3020A RM316 RM324-R2

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

RU Series. Full featured universal miniature relays. Designed with environment taken into consideration.

RU Series. Full featured universal miniature relays. Designed with environment taken into consideration. Universal Series Safety The contact position can be confirmed through the five small windows. Using the latching lever, operation can be checked without energizing the coil. The latching lever is color

More information

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set Accessories 40 Accessories 41 Operating Tools 42 45 Operating Tools WINSTA 46 47 Disconnection Tools 48 Cable Strippers 500 Wire Strippers 501 Cable Cutters 502 Crimping Tools 502 503 Test and Measurement

More information

Through and Ground Conductor Terminal Blocks 290 Series

Through and Ground Conductor Terminal Blocks 290 Series 11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

Siding Components. Installation Guide

Siding Components. Installation Guide Siding Components Installation Guide 2016 MID-AMERICA SIDING COMPONENTS INSTALLATION GUIDE This guide will show you the products of the Mid-America Siding Components family. It provides specific installation

More information

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology Instruction Bulletin 63249-420-283A4 08/2009 Wall Mount Occupancy Sensor SLSWPS1500, SLSWUS1500, SLSWDS1500 INTRODUCTION Wall Mounted Occupancy Sensors are Class 2 devices ideal for use in business or

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive

More information

Pathways Privacy Wall Glass Selections - Sliding Door

Pathways Privacy Wall Glass Selections - Sliding Door Pathways Privacy Wall Glass Selections - Sliding Door #2 ACR BIT 3/16" HEX BIT RAYBO ETCHED GLASS STYLES: Satin Mist PATTERN GLASS STYLES: Waterfall Bamboo Harp Mirage If you have a problem, question,

More information

How to Install Custom Real Wood and Faux Wood Blinds

How to Install Custom Real Wood and Faux Wood Blinds Before you begin your installation: READ ALL INSTALLATION INSTRUCTIONS! Make sure that you have all tools and hardware needed for installation. Check the installation surface (wall, ceiling, or window

More information

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE Check parts against this list before starting assembly. Refer to illustrations on pages 6 and 7 to view house parts. If any shortages are found, refer to Packing Slip for claim instructions. Item 3 5 6

More information

Mounting a BalanceBox 400 to a brick wall

Mounting a BalanceBox 400 to a brick wall Unpack the BalanceBox 400 and remove the Wall frame cover and its bag of screws. Slide the cover out at the top. NOTE: the cover is NOT included with the BalanceBox 400H LOCK SCREW HOLE MOBILE STAND MOUNTING

More information

BX2173 Installation Instructions Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT

BX2173 Installation Instructions Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT BX2173 Installation Instructions 2000-04 Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT Serial No. The front fascia, coolant line bracket and anti-pollution devices are removed for baseplate

More information

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS 1-800-248-7717 1002 N. 15th Street, Middlesboro, KY 40965 FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS Congratulations on your purchase of a Mountain Flip Tarp Dump Body tarping system. With tarping systems

More information

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER. SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions

More information

Preference Collection and Treatment Console INSTALLATION GUIDE

Preference Collection and Treatment Console INSTALLATION GUIDE Preference Collection 5580.69 and 5580.96 Treatment Console INSTALLATION GUIDE WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered. Serving the Truck & Trailer Industry Since 1944 Classic Roll Tarp Attention Dealers: Please give this owners manual to the customer when the product is delivered. Call 800-535-9545 www.aeroindustries.com

More information

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y W8VB The exploded assembly drawing should be used only for authoized service center. W8VB Item No. Part time 1 Magnetic Hex. Socket 2 Sub Stopper 3 O-Ring (S-16) 4 Locator (A) 5 Lock Sleeve (A) 6 O-Ring

More information

Media Storage Systems Fixed Media Cabinets

Media Storage Systems Fixed Media Cabinets Owner s Manual Media Storage Systems Fixed Media Cabinets Contents 1-Column Fixed Media Storage Cabinet Important User Information...........................2 Safety Precautions.................................3

More information

Stripping. Contents. Stripping. Stripping Introduction C.2 C.1. Stripping and cutting tools C.4. Stripping tool C.10

Stripping. Contents. Stripping. Stripping Introduction C.2 C.1. Stripping and cutting tools C.4. Stripping tool C.10 ontents Introduction.2 and cutting tools.4 tool.0 tool for coaxial cable.2. Introduction After a conductor has been cut it is then prepared for the next step or for crimping. For this purpose, a specific

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS COMPACT LAMINATE TOILET PARTITIONS 1080 DuraLineSeries 1180 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information

More information

Assembling Instruction. S418 PV Connector M16 Cable Mount

Assembling Instruction. S418 PV Connector M16 Cable Mount Assembling Instruction S418 PV Connector M16 Cable Mount Electrical Rating: 1000V DC 30A Max. Operation Temperature Range: -40~+90 degree C Caution: 1. Connectors are to be used only to interconnect firmly

More information

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120 Operating Manual for CUTTING, PERFORATING, BENDING SLB120 31040\B06eng 0896 0 Contents 1. Scope of delivery... 1 2. Technical specifications... 1 3. Applications... 1 4. Commissioning... 2 5. Cutting...

More information

RATCHET CABLE CUTTER

RATCHET CABLE CUTTER OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL 764 RATCHET CABLE CUTTER Read and understand this material before operating or servicing this equipment. Failure to understand how to safely operate this

More information

TIP FOR GETTING STARTED

TIP FOR GETTING STARTED Tip for getting started TIP FOR GETTING STARTED Be careful not to drill into any electrical wires, ductwork, plumbing or other damagable components. If you have any questions on the locations of these

More information

SERVICE MANUAL PARTS LIST MODEL: NH40

SERVICE MANUAL PARTS LIST MODEL: NH40 SERVICE MANUAL & PARTS LIST MODEL: NH40 CONTENTS What to do when... 1-3 SERVICE ACCESS Face Cover... 4 Bed Cover... 5 Free-arm Cover... 6 Front Cover... 7 Rear Cover... 8 MECHANICAL ADJUSTMENT Presser

More information

INOVO 2-LITE SLIDING PATIO DOOR

INOVO 2-LITE SLIDING PATIO DOOR INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

1 of 2 3/3/2017 4:49 PM

1 of 2 3/3/2017 4:49 PM 1 of 2 3/3/2017 4:49 PM Front Door Window, Assembly Overview 1 - Window guide - Inserted on flange 2 - Door 3 - Inner window recess seal - Inserted on flange 4 - Bolt - 20 Nm 5 - Carrier assembly - Window

More information

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English Instruction manual SUN-PM100L SUN-PM100L Polishing Machine English Table: SUN-UM-TL-PM001 Version: A/0 Fiber Optic Solutions Provider Ⅰ Safety Precautions To ensure safe operation and maximize product

More information

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY EmagiKit Privacy Pod Plus Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY DIMENSIONS AND COMPONENTS 47 47 Ceiling Unit 2-B 2-L 2-R Glass Door Corner Trim Door Handle 90 Adjustable Height Work Surface 1-B

More information

TorqueMaster Replacement Spring

TorqueMaster Replacement Spring TorqueMaster Replacement Spring Installation Instructions NOTE: Use these installation instructions in conjunction with the TorqueMaster Repair / Replacement Spring Program literature. Copyright 999 Wayne-Dalton

More information

Installation Guide 2016

Installation Guide 2016 Installation Guide 2016 BUILDERS EDGE INSTALLATION GUIDE This guide will show you the products of the Builders Edge family. It provides specific installation steps and application details. Our main goal

More information

Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Top Support Kit: (x2) - 2 Top Supports. Quantities are per bench

Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Top Support Kit: (x2) - 2 Top Supports. Quantities are per bench Parts Included (per back to back bench) Column Kit: (x2) - 1 LH & 1 RH Column - Control Box - Hand Switch Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Depth Support Kit: -

More information

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009) Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009) 3/16" HEX BIT #2 ACR BIT 3/8" HEX SOCKET Full-Height (No Switch) Transom (No Switch) Full-Height (With

More information

Installation Instructions

Installation Instructions Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic

More information

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

C 0.05 ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4 Square or Round Canopy. Section One: Adjusting Cable Position Doc # 90-CST-SQ_0 W. Fullerton Chicago, IL 0 Ph:.0.9 Fax:.9. www.pureedgelighting.com info@pureedgelighting.com 0 PureEdge Lighting. All Rights Reserved. Installation Instructions for Cirrus Channel Suspension

More information

Tools Needed Hardware Provided (per shade) Hardware Needed

Tools Needed Hardware Provided (per shade) Hardware Needed Baby Grande or Grande Motorized (XQ5 Premium) Shade with Cables and Housing Installation Instructions Tools Needed Hardware Provided (per shade) Hardware Needed Drill 3/8 Metal Drill Bit Measuring Tape

More information

PULL-THRU USER S MANUAL

PULL-THRU USER S MANUAL PULL-THRU USER S MANUAL G14x Part # 310 120 177 G20 Part # 310 120 188 G20x Part # 310 120 186 G40x Part # 310 120 163 TABLE OF CONTENTS SECTION 1 PCB DESIGN AND MOUNTING SECTION 2 MOUNTING ADAPTER TO

More information

Frameless Fixed Panel Slider

Frameless Fixed Panel Slider INSTALLATION INSTRUCTIONS Frameless Fixed Panel Slider QCI-5279 SINGLE ROLLER WITH ANTI-JUMP DOUBLE ROLLERS QCI5279 Rev Page Certified 08/09/6 Tools: To install your New Shower Enclosure, you may need

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information