Stop Gates & Stop Logs. Series 500. ine. Manufacturing high quality gates since 1977
|
|
- Blaze Stevens
- 6 years ago
- Views:
Transcription
1 Stop Gates & Stop Logs Series 500 Manufacturing high quality gates since 1977 ine
2 Stop Gates & Stop Logs Series 500 Contents Stop Gate Introduction 3 Model Model Model 503-C 4 Stop Gate Specification 5 Stop Log Introduction 6 Application Chart 6 Model Model Model Stop Log Specification 14 Copyright 1999 WMpps,Ine,
3 Series 500 Stop Gates Aluminum Stop Gates Introduction The stop gates illustrated in this section are the types most commonly used. Rugged aluminum construction is combined with tough, flexible ultra high molecular weight polyethylene (UHMW) scats/seals. This design achieves a very low level of leakage. Stop gates can also be supplied in a similar rugged stainless steel design. PRODUCT DESCRIPTION Frames: Stop Gate frames are designed to be embedded (Model 501), mounted on the face of a wall (Model 503) and mounted in an existing channel (Model 503-C). The side guides are a rugged aluminum extrusion with an easily replaceable polymer seating/sliding liner. The sill is also an aluminum extrusion with an easily replaceable neoprene flush seating surface. Slides: The slide is constructed from flat aluminum plate, sufficiently reinforced for the design head conditions. An appropriate lifting handle is attached near the top of the slide. Leakage: The superior design of the polymer seating surfaces has reduced leakage for these stop gates to 0.10 gallons per minute per foot of wetted perimeter when specified. Model 501 OPENING w 6" (150 mm) r A t fc. TYPICAL BOX-OUT * GUIDE SECTION A-A INVERT I v P > 4 a o V W + 41J (100mm} typical box-out- INVERT SECTION B-B Series 500, Page 3
4 Series 500 Stop Gates Model 503 and 503-C Model 503 OPENING w- f A t A. V GUIDE SECTION A-A W + 7" (175mm) SECTION B-B Model 503-C OPENING wr A t, A.5" GROUT {12 mm) GUIDE SECTION (A-A) OPENING fll.5 GROUT (G1 mm] W + 5" (125mm) INVERT SECTION B-B Series 500, Page 4
5 illc. Series 500 Stop Gates Aluminum Stop Gates General Quality Assurance: The stop gate shall be the product of a manufacturer having 10 years or more experience in the successful design and manufacture of low leakage stop gates under similar design conditions. All welds shall be performed by welders with AWS certification. Performance: Maximum allowable leakage for the stop gates shall be 0.10 gallons per minute per linear foot of wetted perimeter regardless of the direction of the unbalanced head. Acceptable manufacturers: Whipps Inc., Athol, Massachusetts, Series 501,503,503-C or Engineer approved equal. Technical Information: In addition to submittal information required by other sections of these specifications, the stop gate manufacturer may be required to submit design calculations and supporting data for all gates showing stresses, loads and deflection for critical parts under design head conditions. At a minimum, these shall include operating load, slide deflection, slide bending stress and shear stress in stiffener welds. Frame: The frame shall consist of 1/4" minimum thickness extruded aluminum (Alloy T6) incorporating ultra high molecular weight polymer (UHMW) seat/seal facings on both the upstream and downstream sides of the slide. Each seat/seal will be shaped to provide two bearing surfaces and two sealing edges. The gate side guides and invert shall have a minimum weight of 4 lbs./ft. for wall mounted and 3 lbs./ft. for embedded. The gate invert shall contain a removable neoprene seal. Seals attached to the slide will not be acceptable. All necessaiy assembly and anchor bolts shall be type 304 (type 316 optional) stainless steel and shall be provided by the gate manufacturer. Slide: The slide shall be minimum thickness of 1/4" aluminum plate (Alloy 6061-T6) reinforced with stiffeners as required so that at the design head the slide will not deflect more than 1/360 of its width and stress is limited to 7600 psi. Slide stiffeners shall have a minimum weight of 2.5 lbs./ft. The slide shall be provided with a cast aluminum offset lifting handle. Dual lifting handles shall be provided on gates wider than 36". Painting: All aluminum in contact with concrete shall have a heavy shop coat of bitumastic paint. (ANODIZING optional): All aluminum components shall be anodized in conformance with Aluminum Association Specification AA-C22-A41. The anodizing shall be 0.7 mil thick with a nickel acetate sealer. Series 500, Page 5
6 Series 500 Stop Logs Aluminum Stop Logs Introduction Stop Logs have been used for many years to contain water in ponds, tanks, or channels. They are used in applications where their installation or removal is required infrequently. Historically, stop logs have been made from squared timbers as their name suggests. The availability of wood in the sizes, quality and quantity to make traditional stop logs has become increasingly difficult. The lack of dimensional stability in wood also makes it very difficult to provide timber stop logs with predicatable leakage characteristics. As the following chart illustrates, Whipps series 509,510 and 511 Stop Logs are suitable for a large range of channel widths and water depths while providing a guaranteed maximum leakage rate of.05 gallons per minute per linear foot of wetted seal, This series of Aluminum Stop Log has been in continuous production since 1980 providing an affordable and effective water flow control alternative for many types of projects. Stop Log Application Chart (@ 7600 P.S.I. Bending Stress) 70' 60' 50' 40' Depth of Water 30' 20' 10' Series 500, Paijc 6 3' 4' 5' 6' T 8' 91 10' 11' 12' 13' 14' 15' Channel Width
7 Series 500 Stop Logs Advantages The following pages show the standard range of stop log heights, channel widths and total water depths. Many other configurations can be designed to customize these stop logs to accomodate other stop log heights, channel widths or total water depths. All seals are designed to provide 1/8" compliance with the groove sealing surface and also designed to seal correctly when adjacent logs arc laterally offset up to 1/2". All seals are stop log mounted for ease of inspection and repair and to eliminate the potential for damage from debris that is always possible when the side seals are mounted in the sides of the stop log grooves. The Whipps Series of Proprietary Stop Log shapes are normally carried in stock which enables outstanding delivery of stop logs, including custom designs. Stop logs of this type have demonstrated excellent service life in both water and waste treatment plant applications. Design Features " Stop Logs are aluminum (6061-T6), 5/16" minimum thickness and maximum 7600 psi stress. The specially shaped urethanc seal attached to the bottom and ends of the stop logs provides an uninterrupted seal at the face of the stop log groove and the joint between the stop logs. The bottom stop log seals with the flush invert of the channel. The urethane seal is sufficiently compliant to deflect 1/8" under normal conditions of installation and wide enough to provide an adequate seal when adjacent stop logs are laterally offset up to 1/2". All contact surfaces for the stop log seals have a smooth mill finish. Welds on the down stream side of the stop logs are continuous. Adequate drainage is provided for the interior of the stop logs to prevent bouyancy or retention of water. One Piece Molded Polyurethane Comer Seal View of Typical Bottom Corner (Model 510, 12" High Shown) Stop Log Grooves Aluminum Stop Log Grooves are one (1) piece aluminum (6061-T6) extrusions with integral concrete anchors for embedded applications. Face mounted and channel mounted applications as shown on pages 9,11 and 13 are also available. Stainless Steel Stop Log Grooves are a formed and welded with integral concrete anchors for embedded applications. Face mounted and channel mounted applications as shown on pages 9,11 and 13 are also available. Cast Iron Stop Log Grooves are cast with integral concrete anchors and machined on all stop log contact surfaces. This design is for embedded applications only. Scries 500, Page 7
8 Series 500 Stop Logs Model 509 STOP LOG LIFTER 6" HIGH SECTION C-C (OPTIONAL) RELEASE LEVER LIFTING SHACKLE LIP SEAL SIDES (TYP) 12" HIGH SECTION C-C (ILLUSTRATED) FLOOR ELEV. 12 1/4" (311mm) CLEAR OPENING W 18" HIGH SECTION C-C (OPTIONAL) GROOVE HEIGHT 4 H 18" (457mm) L v B W + 5 1/2" (140mm) 24" HIGH SECTION C-C (OPTIONAL) ANCHOR STRAPS NOTE: STOP LOG INSTALLATION ILLUSTRATED - 60" (W) X 66" (V) WITH (5) 12" HIGH MODEL 509 ALUMINUM LOGS AND LIFTER Model 509 Stop Logs are made in the standard heights shown on the right. Please consult the factory if other heights are required. These stop logs are made of Alloy 6061-T6 Aluminum. However this size of slop log can also be manufactured from either Type 304 S.S. or Type 316 S.S. using the sealing system illustrated. Oi 24" Series 500, Page 8
9 Series 500 Stop Logs Model 509 Features STOP LOG GROOVE FEATURES: MATERIALS: -EXTRUDED ALUMINUM -FORMED STAIN. STEEL - CAST IRON CONFIGURATIONS: -EMBEDDED - FACE-MOUNTED -CHANNEL MOUNTED CHANNEL OPENING CLEAR WATERWAY OPENING CHANNEL OPENING SECTION A-A OPTIONAL r 4 1/2" (114mm) FACEMOUNT GROOVE 2 1/2" IGrtmm) SECTION A-A OPTIONAL CHANNEL MOUNT GROOVE INVERT INVERT r SECTION B-B OPTIONAL FACEMOUNT INVERT SECTION B-B OPTIONAL CHANNEL MOUNT INVERT Series 500, Page 9
10 IVhlppS inc Series 500 Stop Logs Model 510 STOP LOG LIFTER. RELEASE LEVER -7 LIFTING SHACKLE 6" HIGH SECTION C-C (OPTIONAL) (152mm) (TYP.). LIP SEAL SIDES & BOTTOM (TYP.) FLOOR ELEV. CLEAR OPENING "W" 12" HIGH SECTION C-C (OPTIONAL) 12 1/4" (311 mm).am 18" HIGH SECTION C-C (ILLUSTRATED) GROOVE HEIGHT V v Qi C-i r A A IS" [457 mm) 24" HIGH SECTION C-C t> ^ n f (OPTIONAL) W + 6 3/4" - (170 mm) NOTE: STOP LOG INSTALLATION ILLUSTRATED - 9S" (W) X 186" (V) WITH (10) 18" HIGH MODEL 510 ALUMINUM LOGS AND LIFTER Model 510 Stop Logs are made in the standard heights shown on the right. Please consult the factory if other heights are required. These stop logs are made of Alloy 6061-T6 Aluminum. However, this size of stop log can also be manufactured from either Type 304 S.S. or Type 316 S.S. using the sealing system illustrated. 24" (610mm] Series 500, Page 10
11 Series 500 Stop Logs Model 510 Features STOP LOG GROOVE FEATURES: MATERIALS: -EXTRUDED ALUMINUM - FORMED STAIN. STEEL - CAST IRON CONFIGURATIONS: -EMBEDDED - FACE-MOUNTED -CHANNEL MOUNTED CHANNEL OPENING CLEAR WATERWAY OPENING CHANNEL OPENING SECTION A-A OPTIONAL FACEMOUNT GROOVE SECTION A-A OPTIONAL CHANNEL MOUNT GROOVE INVERT INVERT r SECTION B-B OPTIONAL FACEMOUNT INVERT SECTION B-B OPTIONAL CHANNEL MOUNT INVERT Scries 500, Page 11
12 Series 500 Stop Logs Model 511 9" HIGH SECTION C-C (OPTIONAL) FLOOR ELEV. CLEAR OPENING W 8 1/4" (TYP.) (210mm) (TYP.) 18" HIGH SECTION C-C (ILLUSTRATED) 18" (457mm) GROOVE HEIGHT V 1* A 27" HIGH SECTION C-C (OPTIONAL) 12- W + 8 3/4" - (220 mm) NOTE: STOP LOG INSTALLATION ILLUSTRATED - 144" (W) X 258" (V) WITH (14) 18" HIGH MODEL 511 ALUMINUM LOGS AND LIFTER 26 3/4" <57Bmm] Model 511 Stop Logs are made in the standard heights shown on the right. Please consult the factory if other heights are required. These stop logs are made of Alloy 6061-T6 Aluminum. However this size of stop log can also be manufactured from either Type 304 S.S. or Type 316 S.S. using the sealing system illustrated. Series 500, Page 12
13 Series 500 Stop Logs r Model 511 Features CHANNEL OPENING STOP LOG GROOVE FEATURES: MATERIALS: -EXTRUDED ALUMINUM - FORMED STAIN. STEEL - CAST IRON CONFIGURATIONS: SECTION A-A STANDARD EMBEDDED GROOVE - EMBEDDED - FACE-MOUNTED -CHANNEL MOUNTED 13" X 5 1/2"B0X0UT (330mm X 1«Jmm) \ INVERT SECTION B-B STANDARD EMBEDDED INVERT CHANNEL OPENING CLEAR WATERWAY OPENING CHANNEL OPENING SECTION A-A OPTIONAL FACEMOUNT GROOVE SECTION A-A OPTIONAL CHANNEL MOUNT GROOVE INVERT SECTION B-B OPTIONAL FACEMOUNT INVERT SECTION B-B OPTIONAL CHANNEL MOUNT INVERT Series 500, Page 13
14 ino. Series 500 Stop Logs Aluminum Stop Logs General Quality Assurance: The stop logs, guide frames and lifter shall be the product of a manufacturer having 10 years ormore experience in the successful design and manufacture of low leakage stop logs under similar conditions. All welds shall be perfonned by welders with AWS certification. Performance: Maximum allowable leakage for the slop logs shall be 0.05 gallons per minute per linear foot of wetted seal. Model Series 509,510,511 or Engineer approved equal. Technical Information: Acceptable manufacturers: Wliipps Inc., Athol, Massachusetts, In addition to submittal information required by other sections of these specifications, the stop log manufacturer shall be required to submit design calculations and supporting data for all logs showing stresses, loads and deflection for critical parts under design head conditions. Stop Logs: The stop logs shall be manufactured from aluminum extrusions, alloy 6061-T6. The extrusions shall have a minimum thickness of 5/16". Maximum bending stress shall not exceed 7600 psi at the maximum head. Each stop log shall be 18" high (Note: for other heights see catalog), identical, and designed to stack in any order. The stop logs shall have resilient lip-type seals that are attached along the sides and across the bottom with type 304 (type 316 optional) stainless steel fasteners. Seals shall be located on the stop logs for easy inspection and easy replacement. Frame mounted seals arc unacceptable. An engraved aluminum tag shall be welded to each log. Tag information shall include location and size of log. ' > Stop Log Groove: The stop log groove shall be constructed of extruded aluminum, alloy 6061-T6 (type 304 stainless steel, type 316 stainless steel or cast iron). The guide frames shall consist of two grooves and an invert member. The stop log groove shall be supplied with type 304 (type 316 optional) stainless steel anchor bolts for face mount and existing channel applications. The invert member shall be designed for minimum flow interference along the bottom of the channel. Stop Log Lifter: The lifter shall be constructed of aluminum, stainless steel, or steel with UM M W guide bars and type 304 (type 316 optional) stainless steel fasteners. The 1 ifter shall be capable of installing and removing all of the logs. Latching and unlatching of the logs shall be easily accomplished by personnel on the operating deck with the use of a lanyard. Painting: All aluminum in contact with concrete shall have a heavy shop coat of bitumastic paint. (ANODIZINGoptional): Allaluminumcomponentsshallbcanodizedinconformancewith Aluminum Association Specification AA-C22-A41. The anodizing shal I be 0.7 mil thick with a nickel acetate sealer. Series 500, Page 14
15 Simple. Reliable. Structurally Sound. Whipps inc.
16 Products manufactured by Whipps, Inc.: Aluminum, Stainless Steel and FRP Gates Aluminum and Stainless Steel Stop Logs Cast Iron Sluice Gates Telescoping Vaives Diverter Gates -Flap Valves 'Tilting Weirs Manufacturing high quality gates since South Athol Road P.O. Box 1058 Athol, MA Telephone: (978) Fax: (978)
Pioneers in Gate Design
Stop Logs Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent Hydro Gate
More informationMEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C
MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of
More informationRodney Hunt. A GA Industries Company Glydaseal Gates
Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal
More informationStainless Steel Gates Series 900 AWWA C561 Compliant
Stainless Steel Gates Series 900 WW C561 Compliant Introduction...2 dvantages...2 3 Design Features...3 Optional Features...4 Gate Selection Criteria...4 5 pplication Chart...6 Sluice Gate Mounting...7
More informationPENSTOCK VALVES. Performance through Excellence
VALVES & MANUFACTURING (1988) LTD. PENSTOCK VALVES Performance through Excellence SLIDEGATES WEIR GATES STOP LOGS SLIDEGATES PRECISION FACE SEALING VALVES WEIR GATES STOP LOGS SLIDEGATES Actuation Installation
More informationA. Extent of structural precast concrete work is shown on drawings and in schedules.
SECTION 03 41 00 - STRUCTURAL PRECAST CONCRETE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification
More informationSECTION METAL FABRICATIONS
SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM
More informationSECTION BULLET- RESISTANT DOORS
1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and
More informationSECTION THERAPEUTIC POOL ACCESSORIES
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 13 17 23.11 THERAPEUTIC POOL ACCESSORIES SPEC WRITER NOTES: Delete between // // if not applicable to project. Also, delete any other item or paragraph not applicable
More informationGENERAL ISOMETRIC LAYOUT
EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM
More informationAVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS
AVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS AVK PENSTOCK RANGE AVK UK is part of the globally renowned AVK group who are based in over 85 countries and are known as one of the leading innovators and manufacturers
More informationSECTION INTERIOR SIGNAGE
SECTION 10 14 02 INTERIOR SIGNAGE PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by
More informationSECTION MANHOLES
SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard
More information1.1 RELATED DOCUMENTS
SECTION 050505 -BEVEL RAIL ENDS PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 Specification Sections
More informationSCI-FAB Product Specifications. Casework Section 1. Part 1 General
SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.
More informationSECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP
1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of
More informationQUALITY THROUGH EXPERIENCE-SINCE 1963
b y H a k o h a v V a l v e s P E N S T O C K S & F L A P V A L V E S by Hakohav Valves ABOUT US QUALITY RELIABILITY Kim Valves started up as Hakohav Valves in 1963 by two young visionary engineers who
More informationSECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3
More informationPRESTON HEALTH SERVICES ARCHITECT S NO. 2700
SECTION 23 3113 - LOW PRESSURE DUCTWORK PART 1 - GENERAL 1.1 SCOPE OF WORK: A. The work required under this section includes all work necessary for a complete installation of ductwork and accessories.
More informationSPECIFICATION: ALUMINUM SLIDE GATES
SPECIFICATION: ALUMINUM SLIDE GATES PART 1 GENERAL 1.1 The Slide gates shall be manufactured from Aluminum material as specified and shall be Flange back type suitable for wall thimble mounting and generally
More informationb. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube
MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,
More information1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"
More informationSeries 9000 Vinyl Horizontal Slider
Series 9000 Horizontal Slider Series 9000 Vinyl Horizontal Slider Contents List of Architectural Drawings...9000HS - 3 Elevations - XO or OX...9000HS - 4 Available Sizes - XO or OX...9000HS - 5 Elevations
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 33 13 (May 2009) Change 2-11/12 --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationDesign and Construction Standards SECTION ATHLETIC LOCKERS
SECTION 10505 ATHLETIC LOCKERS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The provisions of the General Conditions, Supplementary Conditions, and the Sections included under Division 1, General Requirements,
More informationSeries 9000 Vinyl Single Hung
Series 9000 Single Hung Series 9000 Vinyl Single Hung Contents List of Architectural Drawings...9000SH - 3 Elevations - Single Hung...9000SH - 4 Available Sizes - Single Hung...9000SH - 5 Elevations -
More informationSECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section
02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,
More informationINSTALLATION MANUAL Sluice Gates, Stop-logs & Screens
INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens INTRODUCTION During manufacture and assembly of equipment great care is taken to ensure accuracy in mating the sealing faces on frame and doors, especially
More informationStorefront Installation Guide
Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation
More informationP O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I.
SPECIALTY DISPLAY CATALOG P O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I. C O M W H AT C A N W E D O? I T S
More informationWalz & Krenzer, Inc.
08 39 19/WAL BuyLine 9365 Walz & Krenzer, Inc. Watertight Door and Window Watertight Hatch Removable Lip Seal Flood Barrier System 3 Lip Seal Gasket Flood Barriers Flood Barriers and Watertight Closures
More informationMATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.
Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.
More informationSECTION PRECAST CONCRETE STRUCTURES
SECTION 02605 PRECAST CONCRETE STRUCTURES PART 1 GENERAL 1.01 DESCRIPTION A. CONTRACTOR shall provide all professional services, labor, materials, equipment and incidentals as shown, specified and required
More informationMobile Weapons Storage System Specifications
Mobile Weapons Storage System Specifications Whatever your weapon storage needs, Hi-Density s customized Weapons Storage System will be designed to fit your unique specifications. We recognize that security
More informationMANHOLES PART I: GENERAL. A. Precast Concrete Manholes
MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a
More informationINVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS
INVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS INVICTA PENSTOCK RANGE Invicta is a well established, service driven company offering complete valve, penstock and actuator solutions. Invicta Valves was formed
More information.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.
PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Installation
More informationALUMINUM PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy
More informationPENSTOCKS Sluice Gates
Sluice Gates PENSTOCKS ENGINEERED FOR WATER SİSMAT ULUSLARARASI is a well-known penstock supplier, manufacturing high quality, high performance water control gates for all industries as standard designs
More informationSeries 9000 Vinyl Fixed Window
Series 2030 Picture Window Series 9000 Vinyl Fixed Window Contents List of Architectural Drawings... 9000PW - 3 Elevations - 9000 Fixed... 9000PW - 4 Available Sizes - 9000 Fixed... 9000PW - 5 Elevations,
More informationSeries 6000 Vinyl Horizontal Slider
Series 6000 Horizontal Slider Series 6000 Vinyl Horizontal Slider Contents List of Architectural Drawings...6000HS - 3 Elevations - XO or OX...6000HS - 4 Available Sizes - XO or OX...6000HS - 5 Elevations
More informationB. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.
More informationC. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.
SECTION 105113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION WOOD DOORS
SECTION 08211 WOOD DOORS Notice to Vendors: CANV prefers to purchase products that contain tropical wood only if they are certified according to the guidelines of the Forest Stewardship Council (FSC).
More informationAMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and
More informationSECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 05 12 00 - STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationNITTERHOUSE CONCRETE PRODUCTS, INC Molly Pitcher Highway South Chambersburg, PA
NITTERHOUSE CONCRETE PRODUCTS, INC. 2655 Molly Pitcher Highway South Chambersburg, PA 17201 717-267-4505 GUIDE SPECIFICATION FOR ARCHITECTURAL PRECAST CONCRETE INDEX Page PART I - GENERAL...1 A. DESCRIPTION...1
More informationSection Heavy Duty Slide Gates Tender No. [ ] Page 1
Tender No. [ ] Page 1 1.0 GENERAL 1.1 REFERENCES.1 Provide heavy duty slide gates in accordance with the following standards (latest revision) except where specified otherwise..2 American Society for Testing
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationSeries 9000 Vinyl Fixed Window
Series 2030 Picture Window Series 9000 Vinyl Fixed Window Contents List of Architectural Drawings... 9000PW - 3 Elevations - 9000 Fixed... 9000PW - 4 Available Sizes - 9000 Fixed... 9000PW - 5 Elevations,
More informationSeries 6000 Vinyl Single Hung
Series 6000 Horizontal Slider Series 6000 Vinyl Single Hung Contents List of Architectural Drawings...6000SH - 3 Elevations - Single Hung...6000SH - 4 Available Sizes - Single Hung...6000SH - 5 Series
More informationAMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1
Page 1 This section includes AMBICO Bullet Resistant, Wood Doors and Bullet Resistant Steel Frames which meet the UL752 Standard for Bullet-Resisting Equipment. This section relies on both the Canadian
More informationEdgerail Aluminum Bridge Railing System Specification & Installation Instructions
Edgerail System Specification & Installation Instructions Hill & Smith, Inc 1000 Buckeye Park Road Columbus, Ohio 43207 Tel: 614-340-6294 Fax: 614-340-6296 www.hillandsmith.com Section A System Specification
More information4. Metal roof jacks at penetrations and attachments
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SECTION 07 61 00 METAL SHINGLE ROOFING - - - - - - - - - - -
More informationB. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 51 69.10 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-08582 (August 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationPRODUCT DATA CATALOG
PRODUCT DATA CATALOG CONTENTS PAGE STANDARD ELEVATIONS 2 STANDARD ELEVATIONS 3 DOOR SPECIFICATIONS 4 LOUVER SPECIFICATIONS 5 GLAZING SPECIFICATIONS 5 DOOR HANDING CHART 6 CLINE STANDARD HARDWARE LOCATIONS
More information1. ASME A Scheme for the Identification of Piping Systems.
SECTION 40 05 53 - IDENTIFICATION FOR PROCESS PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe markers. 5. Labels. 6. Lockout devices. B. Related Requirements:
More information5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.
2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc
More informationSTEEL PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports
More informationPART MATERIALS. Section Fencing Materials. Description
PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain
More informationSECTION SHEET METAL FLASHING AND TRIM
SECTION 07620 SHEET METAL FLASHING AND TRIM PART 1 GENERAL 1.1 SUMMARY A. Section includes flashings and counterflashings, sheet metal roofing and fabricated sheet metal items, as indicated in Schedule.
More informationInstallation, Operation and Maintenance Manual. RB Weir Gate
Installation, Operation and Maintenance Manual RB Weir Gate INDEX Introduction. Handling and Storage Installation... Weir Gate installation. Concrete Wall Mounted..... Concrete Round Manhole Wall Mounted.
More informationEMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL
EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION 05720 METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL EMMEGI ARCHITECTURAL FENCING is a high quality steel fencing system comprised of a hybrid
More informationSECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.
SECTION 58 PRECAST CONCRETE BOX CULVERT 58.1 DESCRIPTION A. General This work consists of furnishing and installing Pre-cast Concrete Box Culverts. B. Related Work Section 51 Section 52 Section 53 Section
More informationTENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018
SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationPROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES
SECTION 08 1213.17 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Prefinished steel door frames. B. [Sidelites] [, borrowed lites] [, and transom] assemblies. 1.02 RELATED REQUIREMENTS A. Section 06 2000 Finish
More informationWAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence
MILWAUKIE OR #3144-00 ADDENDUM #5 NARRATIVE: 11-08-12 WAL-MART SUPERCENTER #3144-00; Milwaukie, OR: SPECIFICATIONS SPECIFICATIONS Revisions to Specification 02822 Fence Spec division 02822 has been revised
More informationENDURANCE PRODUCT LINE
ENDURANCE PRODUCT LINE The Endurance family of maintenance-free building products is our national best seller, thanks to sound engineering that enables easy and safe installations. Our maintenancefree
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS THESE INSTRUCTIONS COVER THE INSTALLATION OF THE FOLLOWING REAR DOORS WITH OUTSIDE CABLES AND MAXIMUM SECURITY LOCK: 3/4" DryFreight 1-1/8" PolarGuard
More informationSun Windows General Information New Construction Sliding Door Installation Instructions H F
A G B D C H F H E H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape
More informationSECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.
SECTION 22 05 53 IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes nameplates, tags, stencils and pipe markers. B. Related Sections: 1. Section 09 05 00
More informationHSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf
Type: Job: Catalog number: Approvals: / / / / / / Pole Cat. No. Mounting Arm Drilling Pole Finish Optional Optional Pole Optional Duplex Option Base Cove Top Cap/Finial Receptical Specifications Conduit
More information1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.
SECTION 12360 LIBRARY SHELVING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 09200 - Metal Studs, Lath, Suspension Ceiling, Plaster and Stucco. 3. 09660 - Resilient Tile Flooring.
More informationSECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.
SECTION 23 05 53 IDENTIFICATION OF HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes nameplates, tags, stencils and pipe markers. B. Related Sections: 1. Section 09 05 00 Common
More informationSECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION
PAGE 032015-1 SECTION 032015 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More information10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS
10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS 10x12 WOOD SKID FLOOR FLOOR SYSTEM FOR 10x12 TRICO AND FLORA SHEDS RAW MATERIALS LIST: 2 (9) FLOOR FRAMING AND SHEATHING: 1) BAND BOARD 2 x 6 x 12 PRESSURE
More informationCollins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY
PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply
More informationSECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 051200 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationCast Iron Slide Gates
Cast Iron Slide Gates Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent
More informationACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE
acorn WIRE ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES 10 22 13 WIRE MESH PARTITION 10 22 16 FOLDING GATE GUIDE Page 4 / 5 No. 130A All wire type for normal industrial use. 7, 8, 9, 10 and
More informationGENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F
GENERAL INSTALLATION GUIDE: Unless otherwise indicated, all Seven Oaks M.U. Architectural Products materials are to be used for decorative purposes only. All products must be installed using ample amount
More informationConnectors for Cold-Formed Steel Curtain-Wall Construction
The expiration date of this document has been extended until 2/3/3. Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com
More informationFine Builders and Home Hardware
Fine Builders and Home Hardware Since 1876, IVES has been manufacturing fine builders and home hardware with a tradition of product quality and customer service that has established them as an industry
More informationHardened Structures Hardened Shelters, LLC. Explosion Resistant Pre-hung Sealed Blast Door
Hardened Structures Hardened Shelters, LLC Explosion Resistant Pre-hung Sealed Blast Door Drawing number: ASR-50-BD Revision: E Date: December 8, 2008 Table of Contents Contact Information... 3 Description...
More informationA. Submit manufacturer's technical data and installation for each type of sign required.
SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room
More informationSECTION PRECAST HOLLOW CORE PLANKS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof planks. B. Floor planks. C. Accessories. 1.2 RELATED REQUIREMENTS A. Division 01 General Requirements. SECTION 03 4113 PRECAST HOLLOW CORE PLANKS B. Section
More informationKANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION
Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION NOTE: This special provision is generally written in the imperative mood. The subject, "the
More information2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo
2016 Specification Treads, Base, Stringers and other Amenities 09400 Wausau Tile Precast Epoxy Terrazzo PART 1 - GENERAL 1.1 SUMMARY A. Perform all work required to complete, as indicated by the Contract
More information14000 I/O Series Flush Glaze. Fabrication and Installation Instructions
14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6
More informationINSTALLATION MANUAL IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA MANUAL PART NUMBER:
PARTS-1 Model 24562/28562 Crane INSTALLATION MANUAL IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA 50438-0189 641-923-3711 MANUAL PART NUMBER: 99903701 Iowa Mold Tooling Co., Inc. is an Oshkosh Truck
More informationSECTION PRECAST CONCRETE SECTIONAL MANHOLES
SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,
More informationPIVOT DOOR 3400P INSTALLATION INSTRUCTIONS
Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8
More informationThe Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8
September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers
More informationINS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...
INS-88.500-0A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Unpacking the KSCR... 2 2. Splicing the KSCR (If Required)... 4 3. Assemble Curb and Rail Corners... 5 4. Install Cross Bracing (If Required)...
More informationOperating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher
Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand
More informationEmpire & SunWise Collectors. Imperial Collectors. Copperheart ICS (asphalt shingles)
Standoff Mounting Standoff mounting is the simplest and most cost effective way to install SunEarth solar collectors on sloped roof surfaces. Standoff mounting components are designed to lift the collectors
More informationSUBSTATION SECURITY WALL INSTALLATION MANUAL
SUBSTATION SECURITY WALL INSTALLATION MANUAL JULY 26, 2016 OLDCASTLE PRECAST, INC. 3000 New McEver Rd, Acworth, Ga 30101 Substation Security Wall Installation Manual This Installation Manual is intended
More informationFlushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide
Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels
More informationSECTION HOLLOW METAL DOORS AND FRAMES
SECTION 081113 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: Include construction details, material
More information