FLAT TILE ROOF HOOK [HD+] FOR SIDE MOUNT RAILS

Size: px
Start display at page:

Download "FLAT TILE ROOF HOOK [HD+] FOR SIDE MOUNT RAILS"

Transcription

1 FLAT TILE ROOF HOOK [HD+] FOR SIDE MOUNT RAILS Part# Box Quanitity Hooks Hook Hooks & 40 Screws Hook & 2 Screws Type 304 Stainless Steel For Side Mount Rails Screw Size N/A N/A 5/16" X 3" 5/16" X 3" Rev2 Letter A B C D E Description Mounting Screw Holes Rail Slot Size Length of Roof Hook Rail HeiQht From Finished Roof Thickness Size/Length 9mm 10mm x 46mm mm mm 7mm 7mm 89mm 75mm 38mm mm 15mm 84.6mm 30mm A 5830 Las Positas Road, Livermore, California I 3948 Airway Drive, Rock Hill, South Carolina Phone: (844) I Fax: (800) I SolarRoofHook is a division of Quickscrews International Corp.

2 January 23, 2014 To whom this may concern, SolarRoofHook is committed to excellence. All of our parts were tested by a third party test facility for the following. 1. Uplift test 2. Downward load test 3. Water Proof - QuickBOLT only AME Research facility had a current engineer license per the State of California in 2012 and Terrapin Testing had a current engineer license per the State of California in The following is an excerpt from: CALIFORNIA B OARD FOR PROFESSIONAL ENGINEERS AND LAND SURVEYORS g u i d e t o Engineering & Land Surveying for City and County Officials Page 12, Line If the license has expired between the time the engineering documents were prepared and the time when the local agency s review is performed, do the documents need to be re-sealed by a licensee with a current license? (B&P Code 6733, 6735, , ) As long as the license was current at the time the engineering documents were prepared, the documents do not need to be re-sealed prior to review by the local agency. However, any changes (updates or modifications) to the documents that are made following the review by the local agency would have to be prepared by a licensed engineer with a current license and those changes would have to be signed and sealed. We trust the information provided will alleviate any request for the test reports submitted to have a stamp from the current year. Respectfully, Rick Gentry V.P. of Sales & Marketing 5830 Las Positas Rd Livermore, CA Phone: (844) Fax: (800)

3 July 11, 2016 Mr. Jared Wiener SolarRoofHook 5830 Las Positas Road Livermore, CA Project Number C Subject: 90 High Wind Flat Tile Hook (Part # 17632) Laboratory Load Testing Dear Mr. Wiener: As requested, Applied Materials & Engineering, Inc. (AME) has completed load-testing the 90 High Wind Flat Tile Hook; see Appendix A, Figure 1. The purpose of our testing was to evaluate the compressive and tensile (uplift) load capacity of the 90 High Wind Flat Tile Hook attached to a 2"x4" Douglas Fir rafter using two 5/16"Øx4" QS T17 lag screws. SAMPLE DESCRIPTION Mockup samples were delivered to our laboratory on June 3, 2016 and on June 27, Mockup configuration consisted of three 12" long rafters at 6.5"o.c., screwed to 1/2" Structural I plywood. The 90 High Wind Flat Tile Hook is attached through the plywood into a rafter with two fasteners. TEST PROCEDURES & RESULTS 1. Compression Load Test A total of three tests were conducted for compressive load capacity on June 9, 2016 using a United Universal testing machine. Samples were rigidly attached to the testing machine and a compressive load was applied to the hook. The samples were loaded in compression at a constant rate of axial deformation of 0.10 in. /min. without shock until the hook was bent and came in contact with the test board; displacement at maximum load was recorded. Based on the above testing, the average maximum compression load of the 90 High Wind Flat Tile Hook attached to a 2"x4" Douglas Fir rafter using two 5/16"Øx3" lag screws was determined to be 691 lbs. Detailed results are provided in Table I. Test setup and mode of failure are provided in Appendix B, Figure 1. The specific gravity and moisture content of the rafter was tested in accordance with ASTM D2395, Method A (oven-dry). The average specific gravity and moisture content were determined to be and 12.4%, respectively. Page 1 of 10

4

5 TABLE I COMPRESSION LOAD TEST RESULTS 90 HIGH WIND FLAT TILE HOOK (Part #17632) PROJECT NUMBER C TEST NUMBER MAXIMUM COMPRESSION LOAD (lbs) DISPLACEMENT AT MAXIMUM LOAD (in.) MODE OF FAILURE RAFTER SPECIFIC GRAVITY RAFTER MOISTURE CONTENT (%) Hook Contacted Plywood AVERAGE Page 3 of 10

6 TABLE II TENSILE (UPLIFT) LOAD TEST RESULTS 90 HIGH WIND FLAT TILE HOOK (Part #17632) PROJECT NUMBER C TEST NUMBER MAXIMUM TENSILE LOAD (lbs) DISPLACEMENT AT MAXIMUM LOAD (in.) MODE OF FAILURE RAFTER SPECIFIC GRAVITY RAFTER MOISTURE CONTENT (%) Lag Screw Pull-out AVERAGE Page 4 of 10

7 REFERENCES AC , Acceptance Criteria for Joist Hangers and Similar Devices, ICC Evaluation Service. AC , Acceptance Criteria for Test Reports, ICC Evaluation Service. ASTM D , Standard Test Methods for Mechanical Fasteners in Wood, ASTM International. ASTM D , Standard Test Method for Specific Gravity of Wood and Wood-Based Materials, ASTM International Page 5 of 10

8 Page 6 of 10 APPENDIX A

9 FIGURE 1 90 HIGH WIND FLAT TILE HOOK (Part #17632) PROJECT NUMBER C Page 7 of 10

10 Page 8 of 10 APPENDIX B

11 FIGURE 1 90 HIGH WIND FLAT TILE HOOK (Part #17632) COMPRESSION LOAD TEST SETUP PROJECT NUMBER C Figure 1a. Test Setup Figure 1b. Typical Failure Mode Page 9 of 10

12 FIGURE 2 90 HIGH WIND FLAT TILE HOOK (Part #17632) UPLIFT LOAD TEST SETUP PROJECT NUMBER C Figure 2a. Test Setup Figure 2b. Typical Failure Mode Page 10 of 10

FLAT TILE ROOF HOOK [HD+] FOR BOTTOM MOUNT RAILS; NON-ADJUSTABLE

FLAT TILE ROOF HOOK [HD+] FOR BOTTOM MOUNT RAILS; NON-ADJUSTABLE FLAT TILE ROOF HOOK [HD+] FOR BOTTOM MOUNT RAILS; NON-ADJUSTABLE Part # Box Quantity Screw Size 17638 20 Hooks N/A 17639 1 Hook N/A 17642 20 Hooks; 40 Screws 5/16 x 3 17643 1 Hook; 2 Screws 5/16 x 3 5830

More information

ALL TILE ROOF HOOK FOR SIDE MOUNT RAILS; ADJUSTABLE

ALL TILE ROOF HOOK FOR SIDE MOUNT RAILS; ADJUSTABLE ALL TILE ROOF HOOK FOR SIDE MOUNT RAILS; ADJUSTABLE Part # Box Quantity Screw Size 17585 10 Hooks N/A 17586 1 Hook N/A 17587 10 Hooks; 20 Screws 5/16 x 3 17588 1 Hook; 2 Screws 5/16 x 3 17589 10 Hooks;

More information

CURVED TILE ROOF HOOK FOR BOTTOM MOUNT RAILS; ADJUSTABLE

CURVED TILE ROOF HOOK FOR BOTTOM MOUNT RAILS; ADJUSTABLE CURVED TILE ROOF HOOK FOR BOTTOM MOUNT RAILS; ADJUSTABLE Part # Box Quantity Screw Size 17524 10 Hooks N/A 17525 1 Hook N/A 17526 10 Hooks; 20 Screws #14 x 3 17527 1 Hook; 2 Screws #14 x 3 Letter Description

More information

January 8, 2016 Revised March 19, UNIRAC 1411 Broadway Blvd. NE Albuquerque, NM Flat Tile Mount (#KS-RH-AT1) Laboratory Load Testing

January 8, 2016 Revised March 19, UNIRAC 1411 Broadway Blvd. NE Albuquerque, NM Flat Tile Mount (#KS-RH-AT1) Laboratory Load Testing January 8, 2016 Revised March 19, 2018 Mr. Connor Morrison UNIRAC 1411 Broadway Blvd. NE Albuquerque, NM 87102 Project Number 1160001C Subject: Flat Tile Mount (#KS-RH-AT1) Laboratory Load Testing Dear

More information

Revised on 12/13/2011 to Include Tensile Strength Tests. New Construction Composition Mount (QMNC 3-3/4" Finished Height) Load Testing

Revised on 12/13/2011 to Include Tensile Strength Tests. New Construction Composition Mount (QMNC 3-3/4 Finished Height) Load Testing March 23, 2011 Mr. Stewart Wentworth QUICK MOUNT PV 936 Detroit Avenue, Suite D Concord, CA 94518-2539 Revised on 12/13/2011 to Include Tensile Strength Tests Project Number 111114C Subject: New Construction

More information

Solar Division. Product Catalog. Phone: Fax:

Solar Division. Product Catalog.   Phone: Fax: 2013 Solar Division Product Catalog Phone: 800-743-6916 Fax: 800-689-7975 1 TERMS & CONDITIONS Terms & Conditions Pricing We make every effort to ensure that all the information contained within our price

More information

SolarRoofHook CATALOG. (844) A DIVISION OF QUICKSCREWS INTERNATIONAL CORP.

SolarRoofHook CATALOG.   (844) A DIVISION OF QUICKSCREWS INTERNATIONAL CORP. SolarRoofHook A DIVISION OF QUICKSCREWS INTERNATIONAL CORP. 2018 CATALOG Low Profile QuickBOLT with Microflashing. See page 7. Take a look inside at SolarRoofHook s innovative solar mounting solutions

More information

Structural Criteria for Residential Flush-Mounted Solar Arrays

Structural Criteria for Residential Flush-Mounted Solar Arrays Structural Criteria for Residential Flush-Mounted Solar Arrays Planning and Development Building & Safety Division 1. ROOF CHECKS A. Visual Review/Contractor s Site Audit of Existing Conditions: 1) Is

More information

PV System Structural Criteria

PV System Structural Criteria PV System Structural Criteria Town of Atherton Building Department 91 Ashfield Road Atherton, California 94027 Phone: (650) 752-0560 STRUCTURAL CRITERIA FOR RESIDENTIAL ROOFTOP FLUSH-MOUNTED SOLAR ARRAYS

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations TOOLKIT DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations CRITERIA FOR RESIDENTIAL FLUSH-MOUNTED SOLAR ARRAYS STRUCTURAL 1. ROOF CHECKS A. Visual Review/Contractor s Site

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations STRUCTURAL CRITERIA FOR RESIDENTIAL FLUSH-MOUNTED SOLAR ARRAYS 1. ROOF CHECKS A. Visual Review/Contractor s Site Audit

More information

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019 SUNMODO CORPORATION 14800 NE 65 th Street Vancouver, WA 98682 SUNMODO EZ ROOF MOUNT L-FOOT KITS FOR SHINGLE ROOFS CSI Section: 06 25 23 Wood, Plastic, and Composite Fastenings 07 71 00-Roof Specialties

More information

Unirac Installation Manual

Unirac Installation Manual Tile Roof Hook Universal Mount Unirac R Pub 120803-1ii August 2012 A HILTI GROUP COMPANY Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@unirac.com.

More information

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report www.icc-es.org (800) -6587 (56) 699-05 ESR-0 Reissued March, 0 This report is subject to renewal in two years. A Subsidiary of the International Code Council DIVISION: 06 00 00

More information

Pole Mount Installation Manual

Pole Mount Installation Manual Pole Mount Installation Manual Thank You for Choosing AIMS Power! 1. AIMS Power is a leading supplier of solar products, specializing in PV mounting systems. We ensure our products are manufactured to

More information

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3098 Issued February 1, 2011 This report is subject to re-examination in one year. A Subsidiary of the International Code Council

More information

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1790 Reissued September 1, 2012 This report is subject to renewal September 1, 2013. A Subsidiary of the International Code Council

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-2909 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

Unirac Installation Manual

Unirac Installation Manual Tile Roof Hook Universal Mount Unirac R Pub 090727-1ii June 2009 A HILTI GROUP COMPANY Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@unirac.com.

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2608 Reissued January 2016 This report is subject to renewal January 2017. A Subsidiary of the International Code Council DIVISION:

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-6 Reissued April, 009 This report is subject to re-examination in two years. www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council DIVISION:

More information

ALLIGATOR All-Purpose Anchors

ALLIGATOR All-Purpose Anchors ALLIGATOR All-Purpose s Description ALLIGATOR anchors are designed to hold high loads in solid walls, ceilings, and floors... but also hold securely when they encounter an unexpected cavity, such as in

More information

APA Performance Rated Rim Boards

APA Performance Rated Rim Boards D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 87 () 99 0 www.icc es.org ESR 9 Reissued 0/08 This report is subject to renewal 0/09. DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1754 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1754 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners. DESIGN NOTES 1) Allowable loads for more than one direction for a single connection cannot be added together. A design load which can be divided into components in the directions given must be evaluated

More information

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014. ICC-ES Evaluation Report www.icc-es.org (800) -687 (6) 699-0 ESR-0* Reissued August, 0 This report is subject to renewal September, 0. A Subsidiary of the International Code Council DIVISION: 06 00 00

More information

SolarMount (E)volution

SolarMount (E)volution SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution

More information

Originally Issued: 06/28/2012 Revised: 06/21/2017 Valid Through: 06/30/ Design

Originally Issued: 06/28/2012 Revised: 06/21/2017 Valid Through: 06/30/ Design EVALUATION SUBJECT: SIMPSON STRONG-DRIVE SDWC WOOD SCREWS REPORT HOLDER: Simpson Strong-Tie Company Inc. 5956 West Las Positas Boulevard Pleasanton, California 94588 (800) 999-5099 www.strongtie.com CSI

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 87 () 99 0 www.icc es.org ESR Reissued 0/07 This report is subject to renewal 0/08. DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

Featuring TJ Rim Board and TimberStrand LSL

Featuring TJ Rim Board and TimberStrand LSL #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3042 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00

More information

CBUCK Engineering. for. Florida Product Approval # FL R1

CBUCK Engineering. for. Florida Product Approval # FL R1 Evaluation Report Kasselwood Metal Shingle Metal Roof Assembly Manufacturer: (A division of Isaiah Industries) 8510 Industry Park Drive Piqua, OH 45356 (800) 543 8938 for Florida Product Approval # FL

More information

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)? Mobile County Public Works Residential Plan Reviewers Checklist For Structural Requirements of Wood Framed Residences Recommendation: Permit as Noted Revise Plans and Resubmit MCPW Ref. No. Design Criteria:

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

STRUCTURAL ATTACHMENTS

STRUCTURAL ATTACHMENTS Brace Structural Attachment Selection Procedure ) Determine structure to be attached to from the following: A) Concrete B) Wood Beam C) Structural Steel 2) Reference structure connection type from Appendix

More information

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

ESR-1254 * DELETED BY CITY OF LOS ANGELES.   Reissued April 1, 2006 This report is subject to re-examination in one year. ESR-1254 Reissued April 1, 2006 This report is subject to re-examination in one year. www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional

More information

UL Construction No. 254

UL Construction No. 254 UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide

More information

THE ENGINEERED WOOD ASSOCIATION

THE ENGINEERED WOOD ASSOCIATION D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January

More information

PRODUCT EVALUATION Effective July 1, 2009 RC-204

PRODUCT EVALUATION Effective July 1, 2009 RC-204 TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 06 1053 - MISCELLANEOUS ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Division 01 Specification

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

Steep-Slope ApplicAtionS

Steep-Slope ApplicAtionS Steep-Slope ApplicAtionS GreenFasten GF1 PRODUCT GUIDE Exploded Product View/B.O.M. 1 Installation Instructions 2 Cut Sheets 3 Specifications 4 Test Data 5 Price List 6 Exploded Product View, Bill of Materials

More information

Connectors for Cold-Formed Steel Curtain-Wall Construction

Connectors for Cold-Formed Steel Curtain-Wall Construction The expiration date of this document has been extended until 2/3/3. Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com

More information

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA The SIMPLE FRAMING SYSTEMSM INSTALLATION GUIDE USA for Floors This Installation Guide is intended to provide general information for the designer and end-user. For further information, please refer to

More information

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite. Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite. Tracy Hummer, Research Assistant J. Daniel Dolan, Professor Michael Wolcott, Professor Wood Materials

More information

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3870 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 05 00

More information

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM J A Wium Institute of Structural Engineering 19 November 2007 ISI2007-3 TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3096 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 06 00 00 WOOD, PLASTICS

More information

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3528 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

Load Tables, Technical Data and Installation Instructions

Load Tables, Technical Data and Installation Instructions W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting

More information

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

TYPICAL PATIO COVERS.  OWNER: ADDRESS: PHONE: City of Aliso Viejo Building Division 12 Journey, Suite 100 Aliso Viejo, CA 92656 (949)425-2540 Fax (949)425-3899 www.cityofalisoviejo.com TYPICAL PATIO COVERS 111 I. GENERAL Patio covers are one-story,

More information

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1360 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES TESTING APPLICATION STANDARD (TAS) 117(B)-95 TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES 1. Scope 1.1 This Protocol

More information

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

LEGACY REPORT.  (800) (562) A Subsidiary of the International Code Council. *Revised September 2003 ICC-ES Evaluation Report ER-580* Reissued January 00 www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council Legacy report on the 997 Uniform Building Code DIVISION: 05

More information

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016 Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder Installation Instructions Revised 9/2/2016 SBCA has been the voice of the structural building components industry

More information

SDWH TIMBER-HEX Screw

SDWH TIMBER-HEX Screw Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections, Including Ledgers Double-barrier coating provides corrosion resistance equivalent to hot-dip galvanization, making it suitable

More information

*Revised September 1, 2003

*Revised September 1, 2003 LEGACY REPORT ER-580* Reissued January, 00 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 560 Workman Mill Road, Whittier, California 9060 # (56) 699-054 Regional Office # 900 Montclair

More information

EcoFasten Solar. Test Data: C Eco-44 Wood Blocking Product Guide. Engineer s Test Report - C B-44 Bracket Page 1. Page 2 5.

EcoFasten Solar. Test Data: C Eco-44 Wood Blocking Product Guide. Engineer s Test Report - C B-44 Bracket Page 1. Page 2 5. Test Data: C-102-6 Page 1 Page 2 5.1 Test Data: C-102-6 Page 3 Page 4 5.2 Test Data: C-102-6 Page 5 5.3 Test Data: Load Test Load Test Report (for reference only) Machine: Universal or tensile testing

More information

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products March 2002 2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS The 2001 Edition of the National Design Specification

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3164 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

Pryda Timber Connectors

Pryda Timber Connectors Pryda Timber Connectors Pryda Lintel Guide Engineered Steel Wall Lintels March 2014 ESSENTIAL NOTES PRYDA PRODUCT GUIDES INTRODUCTION The information in this Product Guide is provided for use in Australia

More information

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F.

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F. PAGE-1 UPDATED 2-3-2015 REV.5 BLACK WIDOW Detailed installation manual PAGE-2 UPDATED 2-3-2015 SpiderRax, Inc. REVISION PAGE Installation Manual For BW-S, BW-B,BW-F DATE PAGES REASON OLD LEVEL NEW LEVEL

More information

MULE-HIDE PRODUCTS CO., INC FASTENER GUIDELINES

MULE-HIDE PRODUCTS CO., INC FASTENER GUIDELINES FASTENER GUIDELINES Fastener Overview A. Mule-Hide offers a variety of fasteners and plates to: Attach roof insulation Attach mechanically fastened roofing membranes Secure All Purpose Bar and termination

More information

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Elco Construction Products 1301 Kerr Drive Decorah, IA fax: Technical Manual 2010 HangerMate anchors were designed to speed installation of fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. They can also be used to install strut channels,

More information

On-Roof Mounting Sets for Flat-Plate Collectors

On-Roof Mounting Sets for Flat-Plate Collectors Engineering Submittal Sheet Installation sets for collectors Fig. 1 Installation set for 2 collectors 1 basic installation set, 1 extension installation set Basic installation set for each collector array

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-87 (2) 99-043 www.icc-es.org ESR-3332 Reissued 09/207 This report is subject to renewal 09/208. DIVISION: 0 00 00 METALS

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

Wood Connections. Concepts of Well Designed Connections

Wood Connections. Concepts of Well Designed Connections Wood Connections Sam Hensen, P.E. Branch Engineering Manager Concepts of Well Designed Connections Must provide sufficient capacity to transfer loads to supporting members Utilize fastener spacing which

More information

APPLICATION FOR A BUILDING PERMIT

APPLICATION FOR A BUILDING PERMIT APPLICATION FOR A BUILDING PERMIT City of San Jacinto 595 S. San Jacinto Ave San Jacinto CA 92583 95.487.7330 fax 95.654.9896 Must print legibly, submit (3) sets of building and plot plans. Fill out all

More information

Vertical Offset Base and Safety Rail System Installation Instructions

Vertical Offset Base and Safety Rail System Installation Instructions Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat

More information

Connectors for Cold-Formed Steel Curtain-Wall Construction

Connectors for Cold-Formed Steel Curtain-Wall Construction Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com Our Newest Product Line for Cold-Formed Steel Framing Simpson Strong

More information

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/ American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO 80112 Phone: 303/792-9559 Fax: 303/792-0669 404.1. SCOPE STANDARD FOR RADIALLY REINFORCING CURVED GLUED LAMINATED

More information

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply

More information

Pole Mounting System Installation Manual

Pole Mounting System Installation Manual Pole Mounting System Installation Manual Thank You For Choosing Hopergy! Why Hopergy 1. Hopergy is a professional supplier, specialising in PV mounting systems. We have experienced engineers and strong

More information

Face Mount to Through-the-Post Mount

Face Mount to Through-the-Post Mount Face Mount to Through-the- Mount Cable Runs through Two Corners When going around two corners, it s necessary to tension the cable from both ends as shown in Deck 4. Use the 672 series The tensioning devices

More information

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS Architectural Testing TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT Rendered to: DIAMOND DOOR PRODUCTS SERIES/MODEL: Diamond GEM 130 MPH Series PRODUCT TYPE: Out-Swing Steel Entry Door

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.org ESR 2442 Reissued 0/208 This report is subject to renewal 0/209. DIVISION: 06 00 00 WOOD,

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT: 0 ICC ES Evaluation Report ICC ES 000 (800) 687 (6) 699 0 www.icc es.org Most Widely Accepted and Trusted ESR Reissued 0/08 This report is subject to renewal 0/00. DIVISION: 06 00 00 WOOD, PLASTICS AND

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof.

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof. METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD Value through the Roof. Reliable Self-Drilling Performance. Superior Marco Value. Value drives everything we do. That s why our exclusive Weather-Tite

More information

UNA-CLAD Metal Roof Systems

UNA-CLAD Metal Roof Systems UNA-CLAD Metal Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and P Assemblies Factory Mutual Approvals (FM) Table of Contents 1.01 EXTERNAL FIRE RATINGS... 7 Assemblies are updated.

More information

28" Adjustable Solar Tilt Mount ADJ-28. Owner's Manual. Please read this manual BEFORE installing your solar tilt mount

28 Adjustable Solar Tilt Mount ADJ-28. Owner's Manual. Please read this manual BEFORE installing your solar tilt mount 28" Adjustable Solar Tilt Mount ADJ-28 Owner's Manual Please read this manual BEFORE installing your solar tilt mount SECTION 1 Introduction Mounting your solar panel inclined to an optimized angle with

More information

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L EWP Product Guide www.connectors.com For Use With Products Manufactured by THF23140 LSSH179 SKH1720L Lumberton Largo Montgomery Houston Rancho Cucamonga Livermore Thornhill, Ontario 1018-071 2 General

More information

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3072 Reissued 09/2018 Revised 10/2018 This report is subject to renewal 09/2020.

More information

Attached/Detached Patio Cover

Attached/Detached Patio Cover 1 Attached/Detached Patio Cover NOTE: Check with your homeowners association and architectural review committee for Conditions, Covenants & Restrictions (CC&R s). The San Joaquin County has no regulatory

More information

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8949 Building Safety Division (209) 456-8550 Planning Division (209) 456-8500 Public Works/Engineering

More information

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load capacity of 2x

More information

Roof Attachment Overview

Roof Attachment Overview Roof Attachment Overview MY STORY Brandon Gwinner Account Executive OUR RACKING SOLUTIONS - Construction and Sales for over 15 years - SunModo brand representative for over 5 years - OSEIA board of Directors

More information

orientation Conergy SunTop Instructions for professional installation

orientation Conergy SunTop Instructions for professional installation On-roof Framed modules Portrait orientation Landscape Three-tab Shingle Plain tile Slate Double Roman tile Metal roof Material warranty orientation Conergy SunTop Instructions for professional installation

More information

Tech. Bulletin. Spacing. Positioning. Tile Brackets 6.1

Tech. Bulletin. Spacing. Positioning. Tile Brackets 6.1 created JM Tech. Bulletin Rev. Nr. 6.1 Tile Brackets checked JL valid from 28/02/13 Tile brackets are part of the SunLock mounting system for solar photovoltaic (PV) modules. The new SLTB005 adjustable

More information

CSS Central Mount System

CSS Central Mount System CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning

More information

Installation Guide GRP Dormer

Installation Guide GRP Dormer Installation Guide GRP Dormer To ensure optimum performance please follow the correct fitting procedures outlined in this installation guide. Site safety and good building practice should be adhered to

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3564 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

12' Octagon Wood Gazebo

12' Octagon Wood Gazebo 12' Octagon Wood ANY REPRODUCTION, ALTERNATION, OR USE OF STARTING ANY DISCEPANCY SHALL BE REPORTED IN WRITTING BEFORE STARTING DESIGN REQUIREMENTS 1. Governing Code: Including, not limited to: IBC 2015

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3201 Reissued 07/2018 This report is subject to renewal 07/2019. DIVISION: 06 00

More information