Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Size: px
Start display at page:

Download "Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate"

Transcription

1 RIXSON ASSA ABLOY 3/4 Template Jamb 1/8 2- R. Max. 1-7/16 1-1/ /4 7/8 Dia. C L 1-1/4 Dia. Installation Instructions 50 (06-09) Finish Plate 340 TOP PIVOT Pivot Shown Engaged 9/16 1/16 1/4 1-15/32 15/32 21/32 1/4-20 x " FHMS or #14 x 1/2" FHWS Floor Plate 50 Floor Closer Center Hung Single or Double Acting Non-Handed 6-3/4 JAMB PORTION 4-1/ x " FHMS or #12 x 1-1/4" FHWS 1-1/8 DOOR PORTION Floor Plate Cement Case 1-5/16 1/4-20 x " FHMS or #14 x 1-1/2" FHWS 1-1/4 1-3/8 Min. Clearance Required for, Plate H and Shims 7/8 Door Mortised 1-9/16 Deep for 1/8 2- Provide 3/8 Dia. Hole 1-1/16 (11/16 w/ Threshold) Plate 10-3/4 7-7/16 Fasten Front Mounting Screws First 19-1/4 7/16 With Threshold Use Top (2) Holes Cement Case With Floor Plate Use Bottom (2) Holes 1-9/ /8 WITH FLOOR PLATE Set Cement Case Flush with Finished Floor See Note 5 Door Mortised Deep for A 1/4 Threshold 1-1 1/2 Threshold 1-9/16 See Note 5 B A B 1-1/8 7/8 2-3/4 19-1/8 Threshold 1-1/4 1/4-20 x 1 FHMS or #14 x 2 FWHS (4 Places) Conversion from inches to metric: inch x C L 1-25/32 1-7/ /32 2-3/ ARM PLATE H 11/32 2 See Note 4 Tighten Screw Firmly Washer Adapter WITH THRESHOLD Set Cement Case Flush with Finished Floor Notes: 1. Do not scale drawing. 2. Suitable reinforcing by others. 3. Rixson design threshold available on request. 4. Tighten adjusting screw to notched V line on arm to acquire standard initial location of door. Screw moves door towards and away from jamb to equalize door clearances. 5. Provide dia. holes for alignment screws (2 places). 6. Do not remove grind plate until closer is installed. 7. External stop by others required. 8. All dimensions given in inches.

2 PAGE 2 How To Determine Hand of Door LH RH Top Pivot Jamb Portion Top Pivot Door Portion IMPORTANT: Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. Adjusting Screw Plate H Alignment Screws Installation Instructions 1. Locating Closer Door Jamb Position Centerline of Door and A. Measure 2-3/4 out from door jamb on centerline of door. This is the location of the spindle center. 2-3/4 From Face of Jamb to C of L 2. Install Cement Case in Floor LEVEL IN BOTH DIRECTIONS A. Cement case is set flush with finished floor. B. Set cement case with closer in floor and block in position. C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case.

3 3. Install Top Pivot and Closer PAGE 3 A. Install top pivot in door per template. DOOR B. Install top pivot in jamb per template. Plate H Closer in Floor C. Centerline of pivot pin should line up with centerline of spindle. Use plumb line to assure accuracy. If center lines don t line up, loosen hold down screws (4) and reposition closer. Tighten hold down screws closest to spindle first. Then tighten screws at cylinder end. Note: Closer must be lifted approx. 1/8 before repositioning. D. Mortise door for arm, arm plate H, and wood door arm plate. Refer to template. E. Drill two dia. holes for arm alignment screws. Drill 3/8 hole at heel edge of door for adjusting screw. F. Install arm, arm plate H, and shims if required. Attach arm alignment screws and washers to hold arm in place. 4. Hang Door Top Pivot Pin Centerline of Door 30 Pin Retracting Screw CAUTION: Closer is shipped with "valve" screws down. DO NOT FORCE VALVE DOWN. A. Close both valve screws. NEVER FORCE VALVE SCREW DOWN AS THIS WILL DAMAGE TIP SEATING. B. With arm on spindle, turn spindle until arm is in 30 open position (see illustration). C. Set door on spindle. DO NOT ATTEMPT TO CLOSE DOOR. D. Align two portions of top pivot and turn pin retracting screw clockwise to engage top pivot pin. E. Open door to 60 or more and turn valve screws counterclockwise. Door will then close. F. If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. Adjusting Screw G. Adjust arm alignment screws equally from each side to center door in doorway. Alignment Screws

4 Closer Adjustment PAGE BACK CHECK DELAY F S STROKE LATCH F S F S Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. A. The stroke valve allows adjustment from open to 15. B. The latch valve allows adjustment from 15 to closed position. C. IMPORTANT: Back check valve option must be adjusted to vary resistance from light to firm at 70 of door opening. D. The delay valve option allows closing speed adjustment from open position to 65. Repairs, parts replacement or internal adjustments must be done by a Rixson authorized repair agency. Consult for an authorized repair agency in your area. Rixson is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. RIXSON ASSA ABLOY

5 RIXSON 3/4 ASSA ABLOY Template 1/8 1-7/16 1-1/ /4 7/8 Dia. 1-1/4 Dia. TOP PIVOT Installation Instructions 50W (06-09) Finish Plate 9/16 1/16 1/4 1-15/32 15/32 21/32 1/4-20 x " FHMS or #14 x 1/2" FHWS W50 Floor Closer Center Hung Single or Double Acting Non-Handed Wood Door Installation 6-3/4 JAMB PORTION x " FHMS or #12 x 1-1/4" FHWS 1-1/8 DOOR PORTION /16 1/4-20 x " FHMS or #14 x 1-1/2" FHWS 1-1/4 Jamb 2- R. Max. C L Floor Plate 4-1/2 Provide 9/16 Dia. Hole for Alignment Screw Floor Plate 1-3/8 Min. Clearance Required for, Plate H and Shims 1-1/4 Door Mortised 1-7/8 Deep for Cement Case Shim Plate 7/16 Wood Door Plate Shoulder Collar Fasten Front Mounting Screws First 19-1/4 1/8 2-9* 2-1/4* 7-7/16 *Mortised Provide 3/8 Dia. Hole Use Top (2) Holes Cement Case 2 4-3/8 WITH FLOOR PLATE Set Cement Case Flush with Finished Floor Provide 9/16 Dia. Hole for Alignment Screw Door Mortised Deep for A B 1/4 Threshold 1-3/4 1-1/8 1/2 Threshold 1-1/2 7/8 B A 2-3/4 19-1/8 Threshold 2-3/ /32 9/ C L 4-7/32 1-7/32 C L Door 1-13/32 6-7/ /2 WOOD DOOR ARM PLATE Conversion from inches to metric: inch x #14 x 2-1/2 FWHS (6 Places) 11/16 1-3/8 See Note 4 Tighten Screw Firmly WITH THRESHOLD Set Cement Case Flush with Finished Floor Notes: 1. Do not scale drawing. 2. Suitable reinforcing by others. 3. Rixson design threshold available on request. 4. Tighten adjusting screw to notched V line on arm to acquire standard initial location of door. Screw moves door towards and away from jamb to equalize door clearances. 5. Auxiliary stop required. 6. All dimensions given in inches.

6 PAGE 2 How To Determine Hand of Door LH RH Top Pivot Jamb Portion Top Pivot Door Portion Shim Plate H IMPORTANT: Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. Wood Door Plate Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. Adjusting Screw Plate H Alignment Screws Installation Instructions 1. Locating Closer Door Jamb Position Centerline of Door and A. Measure 2-3/4 out from door jamb on centerline of door. This is the location of the spindle center. 2-3/4 From Face of Jamb to C of L 2. Install Cement Case in Floor LEVEL IN BOTH DIRECTIONS A. Cement case is set flush with finished floor. B. Set cement case in floor and block in position. C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case.

7 3. Install Top Pivot and Closer PAGE 3 A. Install top pivot in door per template. DOOR B. Install top pivot in jamb per template. Shim Plate H Closer in Floor Wood Door Plate C. Centerline of pivot pin should line up with centerline of spindle. Use plumb line to assure accuracy. If center lines don t line up, loosen hold down screws (4) and reposition closer. Tighten hold down screws closest to spindle first. Then tighten screws at cylinder end. Note: Closer must be lifted approx. 1/8 before repositioning. D. Mortise door for arm, arm plate H, and wood door arm plate. Refer to template. E. Drill two 9/16 dia. holes for arm alignment screws. Drill 3/8 hole at heel edge of door for adjusting screw. F. Attach arm to spindle using spindle screw supplied and tighten securely. Install arm plate H, wood door arm plate, and shim. 4. Hang Door Top Pivot Pin Centerline of Door 30 Pin Retracting Screw CAUTION: Closer is shipped with "valve" screws down. DO NOT FORCE VALVE DOWN. A. Close both valve screws. NEVER FORCE VALVE SCREW DOWN AS THIS WILL DAMAGE TIP SEATING. B. With arm on spindle, turn spindle until arm is in 30 open position (see illustration). C. Set door on spindle. DO NOT ATTEMPT TO CLOSE DOOR. D. Align two portions of top pivot and turn pin retracting screw clockwise to engage top pivot pin. E. Open door to 60 or more and turn valve screws counterclockwise. Door will then close. F. If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. Adjusting Screw G. Adjust arm alignment screws equally from each side to center door in doorway. Alignment Screws

8 Closer Adjustment PAGE BACK CHECK DELAY F S STROKE LATCH F S F S Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. A. The stroke valve allows adjustment from open to 15. B. The latch valve allows adjustment from 15 to closed position. C. IMPORTANT: Back check valve option must be adjusted to vary resistance from light to firm at 70 of door opening. D. The delay valve option allows closing speed adjustment from open position to 65. Repairs, parts replacement or internal adjustments must be done by a Rixson authorized repair agency. Consult for an authorized repair agency in your area. Rixson is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. RIXSON ASSA ABLOY

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments RIXSON ASSA ALOY Template 3/4 1/8 2- R. Max 1-7/16 1-1/32 2-2-3/4 7/8 Dia. C L Spindle Installation Instructions 3040 (05-09) 9/16 9/32 1/16 Finish Plate 1/4 1-1/4 Dia. 340 TOP PIVOT PIVOT SHOWN ENGAGED

More information

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE. FOR ASSISTANCE,

More information

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE Auxiliary

More information

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR: Model W91 Overhead Concealed s Wood Frame Installation Instructions *Butt or 3/4 Offset Pivot Hung, Multi Sized 1-3, 3-6 Non-Hold Open and Hold Open Models *Other means except 4-1/2" x 4-1/2" or 3/4" offset

More information

Installation Instructions. Installation Type

Installation Instructions. Installation Type Installation Instructions 800 & 8050 Slide Track Door Closers Non Hold Open & Hold Open Models Note: Hold open models are not permitted to be installed in Listed fire door assemblies. PULL SIDE MOUNTED

More information

Installation Instructions. Installation Type

Installation Instructions. Installation Type Installation Instructions 300 & 3050 Slide Track Door Closers Non Hold Open & Hold Open Models Note: Hold open models are not permitted to be installed in Listed fire door assemblies. PULL SIDE MOUNTED

More information

DC3210. Recommended Closer Size

DC3210. Recommended Closer Size Installation Instructions For Non-Hold Open or A Hold Open Arm Option DC3200 Series Multi-Sized thru 6 Regular Arm Universal Door Closers Parallel Arm Jamb Mount See pages 2&3 See pages 4&5 See pages 6&7

More information

7130(F) Series Mortise Exit Devices Installation Instructions

7130(F) Series Mortise Exit Devices Installation Instructions 7130(F) Series Mortise Exit Devices Installation Instructions Outside Trim Device is packed ready for any Yale 650F or 660F Series Trim. End Clamp (3) 8-32 x 5/16" PUFHMS End Cap (2) 1/4-20 x 1" PPHMS

More information

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

1510(F) Surface Vertical Rod Exit Devices Installation Instructions 1510(F) Surface Vertical Rod Exit Devices Installation Instructions Top Mounting Plate (2) 1/4-20 x 3/4" PFHMS Rod Guide Top Rod Shim (2 Supplied) Strike Plate 791 Strike (3) 10-24 x 3/4" PFHMS or (3)

More information

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse EX76 Concealed Vertical Rod Exit Device Preparation Guide and Installation Instructions Box Contents EX76 Concealed Vertical Rod Exit Device Back Bar Active Push Bar Filler Plate Door Kit with Templates

More information

Owner s Maintenance Section

Owner s Maintenance Section Owner s Maintenance Section Table of Contents Heavy Duty 1. Arm Loosening 2. Weather Changes & Closing Speed Adjustments 3. Door Out of Plumb Offset 4. Door Out of Plumb Center Hung 5. Door Sagging Vertical

More information

1500(F) Rim Exit Devices Installation Instructions

1500(F) Rim Exit Devices Installation Instructions 1500(F) Rim Exit Devices Installation Instructions Singe Doors or Pairs (Panic Label) 1500 - RHR 1500 - LHR 1500F - RHR (Fire Label) 1500F - LHR Standard Device Package Devices are packed ready for application

More information

1530(F) Mortise Exit Devices Installation Instructions

1530(F) Mortise Exit Devices Installation Instructions 1530(F) Mortise Exit Devices Installation Instructions Singe Doors or Pairs (2) 12-12-24 PFHUM/WS 798 Universal Strike Standard Device Package Devices are packed ready for application reinforced metal

More information

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS 2 351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE Auxiliary door

More information

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim 7210 Surface Vertical Rod Exit Device Installation Instructions Top Mounting Plate (2) 1/4-20 x 3/4" PFHMS Blade Stop Block Shim (2 Supplied) Strike Plate 791 Strike (3) 10-24 x 1-1/4" PFHMS Top Latch

More information

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions 7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions Shim (2) Supplied Strike Plate 791 Strike (3) 10-24 x 3/4 (19mm) PFHMS Strike Angle Must Engage Strike 12-24 FHPMS

More information

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models 9500 Series Installation Instructions Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models Regular Pages 5 & 6 Parallel Pages 7 & 8 Top Jamb Mount Pages 9 & 10 IMPORTANT: An improperly installed or

More information

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY. SARGENT Installation Instructions for LP8600 x LR8600 & 12-LP8600 x 12-LR8600 Series Low Profile Panic and Fire Exit Devices on Double Egress & Double Doors or LS8600 & 12-LS8600 Low Profile Exit Device

More information

ED5200(A) Series Rim Exit Devices

ED5200(A) Series Rim Exit Devices ED5200(A) Series Rim Exit Devices Installation Instructions (Single Doors or Pairs with Mullion) FM156 4/10 (617350602) For Metal, Composite and Wood Doors of Either Hand End Clamp (3) 8-32 x 5/16" Flat

More information

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions Top OHC Patch Fitting & Bottom Patch Fitting Installation Instructions For Installation Assistance, Call 855.594.6989 www.assaabloyglass.us Tools Needed: Torque Wrench and Bit 5mm Allen Wrench 6 7 /16"

More information

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2 911404-00 Concealed Vertical Rod Exit Device 33/3547A Installation Instructions Devices covered by these instructions: 33/3547A and 33/3548A Concealed Vertical Rod Exit Device 33/3547A-F and 33/3548A-F

More information

Installation Instructions

Installation Instructions Installation Instructions CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility

More information

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted Installation Instructions CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility

More information

316R Series Installation Instructions

316R Series Installation Instructions 316R Series Installation Instructions Multi size 1 thru 6 Non hold open closers CAUTION An incorrectly installed or improperly adjusted closer can cause property damage or personal injury. These instructions

More information

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters. 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com These instructions are presented a in step by step sequence. Please read it through before installation.

More information

THRESHOLDS. Finishing Touch for Floor Closer Installations

THRESHOLDS. Finishing Touch for Floor Closer Installations THRESHOLDS Finishing Touch for Floor Closer Installations Copyright 2001-2018, ASSA ABLOY Accessories and Door Controls Group, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole

More information

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device Installation Instructions FM532 3/11 (Single Doors or Pairs with Mullion) For Doors of Either Hand In U.S.: Corbin Russwin,

More information

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

Instructions for the installation of Ellison Bronze balanced door models #137 & 138 1. A packing list will be found in crate No. 1 of each shipment. The parts in the crates should be checked with this list. If there is any discrepancy, notify Ellison Bronze at once. 2. All parts are numbered.

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 INSTRUCTIONS FOR Door Closer with Hold Open Arms SERIES ADJUSTABLE FROM SIZE THRU 6 FOR INSTALLATION ASSISTANCE CALL SARGENT AT -800-77-77 / www.sargentlock.com Installation Instructions based on Application

More information

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING Strike Shim (2) Supplied Strike Plate (3) 10-24 x 3/4" PFHMS (6) 10-24 x 1/2" PFHMS Top Latch TopTube Concealed Vertical Rod Exit Device Important: For use with metal doors only. Device is packed ready

More information

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device *911403-00* 911403-00 Surface Vertical Rod Exit Device 33/3527A Installation Instructions Devices covered by these instructions: 33/3527A Surface Vertical Rod Exit Device 33/3527A-F (Fire) Surface Vertical

More information

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions 18758 18758 No maintenance required. 2035 EN 4 1 Installation 1a The hand of the door and the closer must be the same. RH or LH will be stamped on the mounting plate. See the proper template for your application.

More information

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill DEVICES COVERED IN THIS DOCUMENT: 4700S Surface Vertical Rod Device 4700SF Fire Exit Surface Vertical Rod Device TOOLS REQUIRED Metal Wood Wood and Metal Screws Sex Bolts #7 Drill ¼ -20 Tap #16 Drill #12-24

More information

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8

More information

Senior Swing. Caution

Senior Swing. Caution *740132* 740132 2800 Overhead Concealed Series 9500 Surface Applied Series Senior Swing Installation Instructions Caution LCN Senior Swing The Senior Swing Power Operator System is a low energy product

More information

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET HIGH EDGE 2 1/4"(57mm) 03079400070 INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET IMPORTANT: THIS LOCK IS NON-HANDED. LOCK IS FACTORY PACKED PREADJUSTED FOR 1³ ₄" (45mm)

More information

Troubleshooting The Product You Have

Troubleshooting The Product You Have Troubleshooting The Product You Have troubleshooting the product contents General Notes Before You tart: Heavy-Duty & hallow Depth Floor Closers...p 3 imilarities of ingle Acting Offset & Center Hung Floor

More information

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162 DEVICES COVERED IN THIS DOCUMENT: 4600 Series Rim Panic Narrow Stile Exit Device 4600 Series Rim Fire Narrow Stile Exit Device OVERVIEW Outside of Door RHR LHR Inside of Door APPLICATIONS 4950 BLADE STOP

More information

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices In U.S.: Corbin Russwin, Inc. 225 Episcopal Road Berlin, CT 06037 USA www.corbinrusswin.com In Canada: Door

More information

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS Ver.2 1300 SERIES CONCEALED VERTICAL ROD DEVICE Top Strike Latch Screws Strike Screws Release Plunger Top Latch Plunger Screws

More information

Installing Your Electronic Deadbolt

Installing Your Electronic Deadbolt Ultra Security Plus Electronic Deadbolt Installation Instructions http://www.hberger.com/video-gallery/electronic-deadbolt New Installation Lock Location Preparation (Skip this section if you door has

More information

WD WD7000 Series

WD WD7000 Series WD-7000 12-WD7000 Series Wood Door Concealed Vertical Rod Multi-Point Lock Installation Instructions Copyright 2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction

More information

CRL JACKSON 900 SERIES

CRL JACKSON 900 SERIES INSTALLATION INSTRUCTIONS CRL JACKSON 900 SERIES FLOOR MOUNTED DOOR CLOSERS CENTER HUNG AND OFFSET crlaurence.com crlaurence.com MODEL No. 990 crlaurence.com Phone: (800) 421-6144 Fax: (800) 262-3299 crlaurence.com

More information

INSTALLATION INSTRUCTIONS Frames and Entrance Doors

INSTALLATION INSTRUCTIONS Frames and Entrance Doors INSTALLATION INSTRUCTIONS Frames and Entrance Doors J 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. FRAMES and ENTRANCES

More information

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection Checkmate Stops & Holders Absolute Door Control and Entire Opening Protection checkmate stops & holders TABLE OF CONTENTS General Information...3 How to Select Product...4 Options...5 Certifications...5

More information

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver EX88 Interlocking Rim Exit Device Preparation Guide and Installation Instructions Box Contents EX88 Interlocking Rim Exit Device Back Bar Filler Plate Active Push Bar Cylinder and Trim Interface Kit Mounting

More information

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

CONCEALED VERTICAL ROD PANIC EXIT DEVICE INSTALLATION INSTRUCTIONS CRL JACKSON 1085-1085P CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0236 ORDER OF

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Installation Instructions for 45HW & 47HW Electrified Mortise Locks Installation Instructions for 45HW & 47HW Electrified Mortise Locks Contents These installation instructions describe how to install your 45HW & 47HW Electrified Mortise Lock. Topics covered include: Finishing

More information

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 4940622 www.sdcsecurity.com Email: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 1. Measure desired height

More information

s tops & holder s Absolute Door Control and Entire Opening Protection

s tops & holder s Absolute Door Control and Entire Opening Protection check mate s tops & holder s Absolute Door Control and Entire Opening Protection Copyright 2001-2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or

More information

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device 911375-00 Surface Vertical Rod Exit Device 98/9927 Installation Instructions Devices covered by these instructions: 98/9927 Surface Vertical Rod Exit Device 98/9927-F (Fire) Surface Vertical Rod Exit Device

More information

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing: CRCODE-202 Mechanical Lock Instruction and Programming Manual Before Installing: 1. Please read the instructions carefully to prevent missing important steps. *Note: Improper installations may result in

More information

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Shim (2) Supplied. Strike Plate. (3) x 5/8 PFHMS or 10 x 1 PFHWS. Top Latch. (3) x 1/4 PRHMS. Latch Cover. (2) 8 x 3/8 PFH AB SMS Installation Instructions ED5400 (A) Series ED5470 (B) Series Surface Vertical Rod Exit Devices Strike Angle Must Engage Strike Top Strike 10-24 PFHMS Top Bracket and Strike required for ED5470. Shim (2)

More information

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110 INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110 The KWE dual swing arm wall mount is designed to provide a broad range of viewing for Small

More information

Preference Collection and Treatment Console INSTALLATION GUIDE

Preference Collection and Treatment Console INSTALLATION GUIDE Preference Collection 5580.69 and 5580.96 Treatment Console INSTALLATION GUIDE WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious

More information

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-727-5477 www.sargentlock.com

More information

Overhead Concealed Closers

Overhead Concealed Closers Overhead Concealed Closers Introduction Rixson Overhead Concealed closers offer an aesthetically appealing way to close a door. In situations where a closer is needed but concealment is required, Rixson

More information

Specialty Closers. High-End Residential High-End Security Gate Solutions

Specialty Closers. High-End Residential High-End Security Gate Solutions Specialty Closers High-End Residential High-End Security Gate Solutions TABLE OF CONTENTS General Information... 3 How to Select Product... 4 Options... 5 Certifications... 6 Limited Warranty... 6 Specifications...

More information

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors TH955 & TH959 Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device Metal, Wood or Composite Doors TH955 Classroom Function TH959 Storeroom Function 1 Template Top DOOR Holes Marked "" OUTSIDE

More information

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles PVC SINGLE DOOR INSTALLATION INSTRUCTIONS Single Pre-Hung Doors are shipped assembled in most cases ready for installation. Check the sill; in some cases you may want a sill in this door or if not requested

More information

Shetland Stalls Installation Instructions

Shetland Stalls Installation Instructions Shetland Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 1/9/18 Before you start Kit can accommodate up to 12 wide stall front

More information

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS TOOLS REQUIRED Rechargeable, variable speed drill 3/8 diameter drill bit 3 Robertson bits #0, #1 and #2 Slot screwdriver Non marring hammer with 1 head Level Caulk or sealant

More information

Shallow Depth Floor Closers. Complete Premium Door Control for Medium-Duty Interior Doors Where Concealment is Desired

Shallow Depth Floor Closers. Complete Premium Door Control for Medium-Duty Interior Doors Where Concealment is Desired Shallow Depth Floor Closers Complete Premium Door Control for Medium-Duty Interior Doors Where Concealment is Desired Table of Contents General Information... 3 How to Select Product... 4 Options... 5-6

More information

Installation Instructions

Installation Instructions VON DUPRIN Installation Instructions 98/9947WDC Concealed Vertical Rod Exit Device Wood Door Applications Devices covered by these instructions: 98/9947WDC Concealed Vertical Rod Device 98/9947WDC-F (Fire)

More information

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Preference Collection 5580 Treatment Console INSTALLATION GUIDE Preference Collection 5580 Treatment Console INSTALLATION GUIDE 0 WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious injury

More information

How To Measure Your Finished Opening

How To Measure Your Finished Opening 3000 Series Bifold Doors How To Measure Your Finished Opening MEASURE FROM RIGHT TO LEFT 2 PLACES (WIDTH) MEASURE FROM TOP TO BOTTOM 2 PLACES (HEIGHT) Tools Required for Assembly: Tools Needed: Phillips

More information

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template). There are three stages to fitting the CL100 mortise case: Stage 1: Marking out the position of the lock. Stage 2: Preparing the door by mortising and drilling holes. Stage 3: Fitting lock, door furniture,

More information

ED3000 Series. Exit Device Parts Manual

ED3000 Series. Exit Device Parts Manual ED3000 Series Exit Device Parts Manual Table of Contents Functions...3 ED3200 Series Rim Exit Device...4 ED3200A Series Rim Exit Device - Fire Rated...5 ED3400 Series Surface Vertical Rod Exit Device...-7

More information

BEFORE STARTING INSTALLATION

BEFORE STARTING INSTALLATION VON DUPRIN Installation Instructions 22 Rim Device Devices covered by these instructions: 22 Rim Device 22-F Fire Exit Rim Device BEFORE STARTING INSTALLATION 1. Check hardware schedule for strikes, fasteners,

More information

Heavy-Duty Bypass Track System

Heavy-Duty Bypass Track System Heavy-Duty Bypass Track System Please Note: This track system must be installed with the screws going into a solid surface such as studs or a header. Due to the spacing of the holes on these Brackets,

More information

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices *D-1030* D-1030 F-XX-C & XX-C Exit Devices Installation Instructions 8 REVERSING INSTRUCTIONS TO REVERSE THE HANDING OF A (F)XX-C DEVICE NOTE: TO REVERSE TRIM, REFER TO SEPARATE INSTALLATION SHEETS. 1

More information

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation UNIVERSAL HARDWARE CLOSER UH61 & UH62 STALLATION STRUCTIONS The Professional s Choice MULTI SIZE 1 THRU 6 NON HOLD OPEN CLOSER CAUTION! An incorrectly installed or improperly adjusted door closer can cause

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

Double Frameless Swing Door QCI5247

Double Frameless Swing Door QCI5247 INSTALLATION INSTRUCTIONS Double Frameless Swing Door QCI5247 WALL MOUNT HINGES QCI5247 REV. 0 Page 1 Certified 06/16/2016 Parts List with wall mount hinges *Quantities may vary **Quantities double where

More information

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 1. Measure desired height

More information

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C Installation Instructions 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC 7-2-1997 & UL-10C Door Requirements: Consult the door manufacturer to make sure that the doors are qualified

More information

SolidStep 3.0 OEM INSTALLATION MANUAL

SolidStep 3.0 OEM INSTALLATION MANUAL SolidStep 3.0 OEM INSTLLTION MNUL TBLE OF CONTENTS Information 2 Safety 2 Preparation 2 Resources Required 2 Prior to Installation 3 Installation 3 Place ssembly Inside Doorframe 3 djust Transport Lock

More information

Series 9000 Panel Door; In-Line, Corner and Permanent Wall Application

Series 9000 Panel Door; In-Line, Corner and Permanent Wall Application Series 9000 Panel Door; In-Line, Corner and Permanent Wall Application 5/32" Drill Bit In-Line Corner Permanent Wall 3/16" Allen Wrench If you have a problem, question, or request, call your local dealer,

More information

ESA-300 Full Breakout

ESA-300 Full Breakout Interior View 0 Installation Instructions For use with ESA II Controler DORMA AUTOMATICS, Inc. 94 Sherwood Drive Toll-Free: 877-67-6 DL844-00 Lake Bluff, IL 60044 Fax: 877-4-7999 Rev. /07 Tools Required:

More information

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009) Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009) 3/16" HEX BIT #2 ACR BIT 3/8" HEX SOCKET Full-Height (No Switch) Transom (No Switch) Full-Height (With

More information

WPS crew Doors Installation instructions

WPS crew Doors Installation instructions WPS-132-133 crew Doors Installation instructions ORDER OF INSTALLATION FOR A COMPLETE ENCLOSURE OF A CREW WPS (Weather Protection System) IS AS FOLLOWS: 1. Heater 2. Rear Thresholds - Right Hand & Left

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

MORTISE LOCK INSTALLATION INSTRUCTIONS

MORTISE LOCK INSTALLATION INSTRUCTIONS MORTISE LOCK INSTALLATION INSTRUCTIONS INSPIRE TM ROSELESS DESIGNER TRIM FM 340 Rev. 10/18 TABLE OF CONTENTS: DOOR PREPARATION 1 ML2000 LOCK HANDING 2 FULL WORKING TRIM (STD) 3 HALF WORKING TRIM (M30)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information on last page. Review

More information

Tools Required. * When installing on a fire door, please see instructions below. *

Tools Required. * When installing on a fire door, please see instructions below. * CL615 Tubular Mortice Latch with Code Free option CL615 Tubular Mortice Latch with Code Free option Number relating to picture Item 1 Front Plate and handle * 2 Back Plate and handle * 3 Neoprene seals

More information

5200 Series Door Closer Installation Instructions

5200 Series Door Closer Installation Instructions 5200 Series Door Closer I-C00187 R2 Regular Arm See Page 2 An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These installation instructions should

More information

Installation Instructions

Installation Instructions Installation Instructions 8000/8300 Series Electric Strike Product Components HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 www.hesinnovations.com 1 1 2 8000/8300 Electric Strike Body Sticky

More information

Victory Fire Door Inspections

Victory Fire Door Inspections Vickie Evans, FDAI Over 30 years in door and hardware industry DHI instructor and Education Advocate Certified Fire Door Inspector To compartmentalize a building Deter the spread of smoke and flames Fire

More information

ESA-200 Fixed Sidelite

ESA-200 Fixed Sidelite Exterior View Installation Instructions For use with ESA II Controller 1 Tools Required: Suggested Fasteners Required - (Not supplied) Screwdrivers Small Straight (FlatBlade) - for Terminal Block wiring

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 1350 COMBAT SERIES TOILET PARTITIONS IMPORTANT: Review these instructions thoroughly prior to installation. In the United States: BOBRICK WASHROOM EQUIPMENT INC. 200 Commerce

More information

Finish Hardware. Contents. Section 10

Finish Hardware. Contents. Section 10 Section 10 Finish Hardware Contents 10.0.0 Introduction to contents 10.1.0 Door hinges (types and illustrations) 10.2.0 Locksets and latchset configurations and functions 10.3.0 Heavy-duty mortise cases,

More information

ICU TRACKLESS SLIDING DOOR

ICU TRACKLESS SLIDING DOOR Interior View 0 Installation Instructions Tools Required: Screwdrivers Small Straight (Flat Blade) - for Terminal Block wiring # Phillips (Crosspoint) - for various #8, #0, and #4 screws Wrenches / Sockets

More information

Installation Instructions for 45H & 47H Mortise Locks

Installation Instructions for 45H & 47H Mortise Locks Installation Instructions for 45H & 47H Mortise Locks Contents These installation instructions describe how to install your 45H & 47H Mortise Lock. Topics covered include: Finishing the preparation...

More information

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box.

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box. RECEIVING 1. Immediately inspect shipment for damage during transit, for example: damage caused by fork lifts, stacking, water stains etc. and disclose to delivery driver prior to signing for receipt.

More information

SECTION FINISH HARDWARE

SECTION FINISH HARDWARE SECTION 08710 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Finish Hardware as shown and detailed on the Drawings

More information

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL) *24739468* 24739468 98/9950WDC Installation Instructions 1-Point Latch (LBL) Fire-Rated Devices include these additional components Metal Edge Wrap required for 60 and 90-minute applications 2-Point Latch

More information

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32 with up to 200mm x 200mm VESA Mounting Patterns Page 1 of 6 LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns A multi-position dual articulating arm for flat screens up to 60

More information