CITY OF LOS ANGELES CALIFORNIA

Size: px
Start display at page:

Download "CITY OF LOS ANGELES CALIFORNIA"

Transcription

1 BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR United Steel Products Company RESEARCH REPORT: RR Southcross Drive, Suite 200 (CSI #06090) Burnsville, MN BASED UPON ICC ES LEGACY Attn: Greg Greenlee REPORT NO. (952) REEVALUATION DUE DATE: Local Representative: Howard Silverman August 1, 2009 (562) DEPARTMENT OF BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES, CA ANDREW A. ADELMAN, P.E. GENERAL MANAGER RAYMOND CHAN EXECUTIVE OFFICER GENERAL APPROVAL - Reevaluation/Clerical Modification - USP Lumber Connectors - Joist Hangers, Framing Anchors and Clips, Rafter Ties, Tie-Down Anchors and Framing Connectors. DETAILS The above assemblies and/or products are approved when in compliance with the description, use, identification and findings of Legacy Report No., dated January 1, 2003, of the ICC Evaluation Service, Incorporated. The report, in its entirety, is attached and made part of this general approval. The parts of Legacy Report No. marked by the asterisks are deleted or revised by the Los Angeles Building Department from this approval. The approval is subject to the following conditions: 1. The allowable loads specified in this report for tilt-up/reinforced masonry wall anchors shall not be used in the repair, retrofit and new construction for the connection of walls to horizontal wood diaphragms. 2. The allowable loads specified in this report for continuity ties/straps shall not be used for the repair, retrofit and new construction of tilt-up/reinforced masonry buildings. 3. A 25% reduction in all allowable loads specified in the research report shall be taken in hold-down devices as required by Section of the 2002 Los Angeles City Building Code. RR Page 1 of 7 LADBS G-5 (Rev. 7/05) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

2 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors 4. The allowable values for the following products shall be in accordance with the attached table lettered A and shall be subject to the requirements of the corresponding tables in the attached ICBO evaluation report. TABLE PRODUCT TABLE IN ICBOES REPORT A TFI 18 B SU Series The allowable loads for C Post Caps shall be determined by calculations prepared by an engineer or architect licensed in the State of California and approved by the Structural Plan Check. 6. Solid blocking shall be required for all joist hangers. 7. Steel materials shall conform to the specification as shown on the referenced Evaluation Report. Test data verifying the properties of the steel, by the mill or by an approved testing agency, shall be obtained for each shipment. The data shall be kept on file and submitted to the Department upon request. 8. Allowable loads in the tables are for the wood fastening devices and its fasteners and does not include supporting members.. The supporting members shall be checked separately for structural adequacy.. 9. Approved products to be used shall be indicated on the approved set of plans. 10. The supported end of the joist or beam shall be within 1/4-inch from the supporting header. 11. Nails shall be common nails except where otherwise specified. Bolts shall conform to ASTM A 307 or better. 12. Approved products shall be identified with the name United Steel Products Company or the USP trademark along with the model number stamped on them. 13. All welded products shall be fabricated by Los Angeles City Department of Building and Safety licensed fabricator USP - West Division, 2150 Kitty Hawk Road, CA RR Page 2 of 7

3 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors DISCUSSION The clerical modification is to change the address, and the telephone number. The status of the referenced Legacy report No. ER dated January1, 2003, which is currently beyond its re-examination date is still valid. The validity of the Legacy report was verified with ICC. The approval is based on tests and analyses. This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this approval have been met in the project in which it is to be used. This general approval will remain effective provided the Evaluation Report is maintained valid and unrevised with the issuing organization. Any revisions to the report must be submitted to this Department, with appropriate fee, for review in order to continue the approval of the revised report. Addressee to whom this Research Report is issued is responsible for providing copies of it, complete with any attachments indicated, to architects, engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. YEUAN CHOU, Chief Engineering Research Section 2319 Dorris Place Los Angeles, CA Phone - (213) Fax (213) RB:elcm RR23888/wp8.0 R08/29/07 5D2/2311 Attachments: ICC ES Legacy Report No. (31 Pages). RR Page 3 of 7

4 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors TABLE A Allowable Loads for TFI Series Joist Hangers Model Header Nails Allowable Loads (pounds) Normal TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFIS d 1350 See Table No. LII of the ICBO ES Evaluation Report No for footnotes and dimensional characteristics. RR Page 4 of 7

5 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors TABLE A (continued) Model Header Nails Allowable Loads (pounds) Normal TFIS d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 See Table No. 18 of the ICBO ES Evaluation Report No for footnotes and dimensional. RR Page 5 of 7

6 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors TABLE A (continued) Model Header Nails Allowable Loads (pounds) Normal TFI d 1350 TFI d 1350 TFI d 1350 TFI d 1350 TFIS d 1350 TFIS d 1350 TFIS d 1350 TFI d 1350 See Table No. 18 of the ICBO ES Evaluation Report No for footnotes and dimensional characteristics. RR Page 6 of 7

7 United Steel Products Company RE: USP Lumber Connectors - Joist Hangers, Framing Anchors, and Clips Rafter Ties, Tie-Down Anchors and Framing Connectors TABLE B Allowable Loads For SU Series Joist Hangers Allowable Loads lbs Stock No. Downward 100% 115% 125% Uplift 133% SU SU SU SU See Table No. 15 of the ICBO ES Evaluation Report No for footnotes, fastener schedule and dimensional characteristics. RR Page 7 of 7

8 LEGACY REPORT Issued January 1, Business/Regional Office 5360 Workman Mill Road, Whittier, California (562) Regional Office 900 Montclair Road, Suite A, Birmingham, Alabama (205) Regional Office 4051 West Flossmoor Road, Country Club Hills, Illinois (708) Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code DIVISION: 06 WOOD AND PLASTICS Section: Wood and Plastic Fastenings USP LUMBER CONNECTORS : JOIST HANGERS, FRAMING ANCHORS AND CLIPS, RAFTER TIES, TIE- DOWN ANCHORS, FRAMING CONNECTORS, COLUMN BASE AND STUD-PLATE TIE CONNECTORS UNITED STEEL PRODUCTS COMPANY 703 ROGERS DRIVE MONTGOMERY, MINNESOTA SUBJECT USP Lumber Connectors : Joist Hangers, Framing Anchors and Clips, Rafter Ties, Tie-Down Anchors, Framing Connectors, Column Base and Stud-plate Tie Connectors. 2.0 DESCRIPTION 2.1 A3 Framing Angle Clip: The A3 Framing Angle Clip is fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. It is prepunched with round holes to receive the required fasteners. See Table 1 for dimensions, fastener schedules, and allowable loads. 2.2 C Series Post Caps: The C Series Post Caps are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. Each pair of opposing legs is bent at right angles in opposite directions, with one pair bent upward and one pair bent downward. The C Series Post Caps are prepunched with round holes to receive the required fasteners. See Table 2 for dimensions, fastener schedules, and allowable loads. 2.3 D Series Post Anchors: The D Series Post Anchors are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The D Series Post Anchors are prepunched with round holes to receive the required fasteners. See Table 3 for dimensions, fastener schedules, and allowable loads. 2.4 FH and FHD Series Formed Seat Hangers: The FH and FHD Series Formed Seat Hangers are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The FH Series Formed Seat Hanger is a topmount-type hanger, with the sides twisted outward near the top to form a single plane, with the back flat against the face of the header. The upper portion of the hanger is bent at 90 degrees to form a top flange that installs on top of the header. The FHD Series Formed Seat Hanger is similar to the FH hanger, except that the FHD hanger is formed into a single piece that straddles the header and receives a joist on either side of the header. Hangers of both Formed Seat Hanger series are prepunched with round holes to receive the required fasteners. See Table 4 for dimensions, fastener schedules, and allowable loads. 2.5 HD Series Heavy-duty Face Mount Hangers: The HD Series Heavy-duty Face Mount Hangers are fabricated from No. 14 gage [ inch (1.9 mm) basemetal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hangers are prepunched with round holes to receive the required fasteners. See Table 5 for dimensions, fastener schedules, and allowable loads. 2.6 HH Series Header Hangers: The HH Series Header Hangers, designed to replace jack studs supporting wood headers over door or window openings, are fabricated from No. 16 gage [ inch (1.52 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hangers are prepunched with round holes to receive the required fasteners. See Table 6 for dimensions, fastener schedules, and allowable loads. 2.7 HL Series Beam and Purlin Hangers: The HL Series Beam and Purlin Hangers are top-mount-type hangers, flanged at right angles to permit direct nailing to the joist and header. The joist flanges have their apexes at the top, while the header flanges have their apexes at the bottom. The HL Series Beam and Purlin Hangers are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33, and are prepunched with round holes to receive the required fasteners. See Table 7 for dimensions, fastener schedules, and allowable loads. 2.8 LS Series Light Slope Hangers: The LS Series Light Slope Hangers are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The slope of the seat can be field-adjusted down to a maximum of 30 degrees from horizontal. The hangers are ICC-ES legacy reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2005 Page 1 of 30

9 Page 2 of 30 prepunched with round holes to receive the required fasteners. See Table 8 for dimensions, fastener schedules, and allow-able loads. 2.9 PHG Series Panel Hangers: The PHG Series Panel Hangers are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The side flanges of the hanger are turned in to provide a gripper for joist connections. The hangers are prepunched with round holes to receive the required fasteners. See Table 9 for dimensions, fastener schedules, and allowable loads RT6 Rafter/Hurricane Tie: The RT6 Rafter/Hurricane Tie is fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33, and is prepunched with round holes to receive the required fasteners. See Table 10 for dimensions, fastener schedules, and allowable loads SCA Series Stair Angles: The SCA Series Stair Angles, used to attach the tread to the stringer, are manufactured from No. 12 gage [ inch (2.66 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The angles are prepunched with round holes to receive the required fasteners. See Table 11 for dimensions, fastener schedules, and allowable loads SFC Series Framing Clips: The SFC Series Framing Clips are used to connect studs to plates, posts to sills, or window sills to studs or mullions. The SFC Series Framing Clips are fabricated from No. 16 gage [ inch (1.52 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33, and are prepunched with round holes to receive the required fasteners. See Table 12 for dimensions, fastener schedules, and allowable loads SP Series Speed Prong Hangers: The SP Series Speed Prong Hangers are face-mount type hangers fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hangers are flanged at right angles to permit direct mounting to the joist and header. The SP Series Speed Prong Hangers have prongs in the joist flanges to permit quick setting of the joist in the hanger. The header flanges must be nailed to the header. The hangers are prepunched with round holes to receive the required fasteners. See Table 13 for dimensions, fastener schedules, and allowable loads SU Series Joist Hangers: The SU Series Joist Hangers are face-mount-type hangers manufactured from No. 18 gage [ inch (1.21 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hangers are flanged at right angles to permit direct nailing to the joist and header, and are prepunched with round holes to receive the required fasteners. See Table 14 for dimensions, fastener schedules, and allowable loads SUH Series Joist Hangers: The SUH Series Joist Hangers are face-mount-type hangers fabricated from No. 16 gage [ inch (1.52 mm) basemetal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hangers are flanged at right angles to permit direct nailing to the joist and header, and are prepunched with round holes to receive the required fasteners. See Table 15 for dimensions, fastener schedules, and allowable loads TDL Series Concrete Angles: The TDL Series Concrete Angles are used to hold studs or posts to concrete foundations, and are fabricated from No. 12 gage [ inch (2.66 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The angles are prepunched with round holes to receive the required fasteners. See Table 16 for dimensions, fastener schedules, and allowable loads TFI Series I-Joist Hangers: The TFI Series I-Joist Hangers are manufactured from No. 16 gage [ inch (1.52 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The hanger seat is 2 1 / 2 inches (63.5 mm) deep, offset 1 / 4 inch (6.4 mm) from the face of the supporting member, with widths corresponding to the particular supported member dimension. The hangers also include 45-degree-angled nailing provisions for attachment to the I-joist s laminated wood flanges. The TFI I-Joist Hangers are prepunched with round holes to receive the required fasteners. Optional nailing tabs are provided to meet specific load and/or installation requirements. See Table 17 for dimensions, fastener schedules, and allowable loads WE Series Wet Anchors: The WE Series Wet Anchors are manufactured from No. 12 gage [ inch (2.66 mm) base-metal thickness] G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The pronged portion of the anchors is designed to be embedded into fresh, screeded concrete to provide shear and uplift resistance for the supported post. The anchors are prepunched with round holes to receive the required fasteners. See Table 18 for dimensions, fastener schedules, and allowable loads HUS Face-mounted Joist Hangers: The HUS Joist Hangers are designed to support two or three plies of nominal 2-by-4, -6, -8, 10, -12 or -14 joist lumber, or one ply of nominal 4-by-4, -6, -8, -10, -12 or -14 joist lumber. The hangers are fabricated from No. 14 gage [ inch (1.9 mm) base-metal thickness] ASTM A 653, SS Grade 33, galvanized steel. The hangers are 3 1 / 8, 3 5 / 8 or 4 5 / 8 inches (79, 92 or 117 mm) in width and 2 inches (51 mm) in depth, with varying heights. The HUS Joist Hanger is prepunched to accept 16d common nails for attachment of hanger to the joist and header, as shown in Figure 19. The nails are driven through the joist at a maximum angle of 45 degrees so that the nail penetrates a minimum of 1 inch (25.4 mm) through the corner of the joist into the header. The joist is to butt up to within 1 / 8 inch (3.2 mm) of the header. The HUS Joist Hanger is available with header flanges bent out or in (inverted). See Figure 19 for installation details, and Table 19 for nailing schedules, dimensions, and allowable loads JUS Face-mounted Joist Hangers: The JUS Joist Hangers are designed to support two or three plies of nominal 2-by-4, -6, -8, -10, -12 or -14 joist lumber, or one ply of nominal 4-by-4, -6, -8, -10, -12 or -14 joist lumber. The hangers are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness] ASTM A 653, SS Grade 33, galvanized steel. The hangers are 3 1 / 8, 3 5 / 8 or 4 5 / 8 inches (79, 92 or 117 mm) in width and 2 inches (51 mm) in depth, with varying heights. The JUS hanger is prepunched to accept 16d common nails for attachment of hanger to the joist and header, as shown in Figure 20. The nails are driven through the joist at a maximum angle of 45 degrees so that the nail penetrates a minimum of 1 inch (25.4 mm) through the corner of the joist into the header. The joist is to butt up within 1 / 8 inch (3.2 mm) of the header. See Figure 20 for installation

10 Page 3 of 30 details, and Table 20 for nailing schedules, dimensions, and allowable loads CBS Column Base Anchor: The CBS Column Base Anchors are column-post-to-concretefoundation-and-slab connectors used to provide uplift resistance. The column base anchor consists of a strap formed into a U-shape with a formed base support located between the upstanding legs, as shown in Figure 21. The base support is factor-riveted to the upstanding legs. The column base anchors are embedded into the concrete up to the bottom of the base support, with minimum 7 3 / 16 -inch (188 mm) embedment depth and minimum 3-inch (76 mm) concrete side cover as specified in Table 21. The base support is designed to provide standoff bearing support from the concrete for nominal 4-by-4, 4-by-6 or 6-by-6 column posts. The wood posts shall be fastened to the column base anchor utilizing two 5 / 8 -inch-diameter (15.9 mm) bolts. The U- shaped strap is fabricated from No. 10 gage [ inch (3.42 mm) base-metal thickness] galvanized steel. The column base supports are fabricated from either No. 16 gage [ inch (1.52 mm) base-metal thickness] or No. 12 gage [ inch (2.66 mm) base-metal thickness] galvanized steel conforming to ASTM A 653, SS Grade 33. The No. 12 gage base support is used with 6-by-6 column posts. The concrete shall have a minimum compressive strength of 2,000 psi (13.8 MPa) at 28 days. Dimensional characteristics and allowable loads are shown in Table RSPT Reversible Stud-plate Tie Connectors: The RSPT Reversible Stud-plate Tie Connectors anchor nominal 2-by wall top plates or bottom sill plates to vertical stud members. The connectors are fabricated from No. 20 gage [ inch (0.91 mm) base-metal thickness], G60 galvanized steel conforming to ASTM A 653 CS, with a minimum yield and ultimate strength of 28 and 38 ksi (193 and 262 MPa), respectively. The stud-plate is 1 1 / 2 inches (38 mm) wide and 4 1 / 8 inches (105 mm) long. The stud-plate face has two parallel ribs running along the length of the plate and is prepunched to receive four 8d common nails on each end. See Figure 22 for descriptive details, and Table 22 for nailing schedules, dimensions, and allowable loads SPTH Stud-plate Tie Strap Connectors: The SPTH Stud-plate Tie Strap Connectors anchor nominal 2-by wall top plates or bottom sill plates to vertical stud members. The stud-plate tie strap connectors are fabricated from No. 18 gage [ inch (1.21 mm) base-metal thickness], G60 galvanized steel conforming to ASTM A 653, SS Grade 33. The stud-plate tie strap consists of a U-shaped, 1 1 / 4 -inch-wide (32 mm) strap, available in various leg lengths; and is prepunched to receive six 10d common nails on each leg. See Figure 23 for descriptive details, and Table 23 for nailing schedules, dimensions, and allowable loads THDH Face-mounted Joist Hanger: The THDH Face-mounted Joist Hangers are designed to support two or three plies of nominal 2-by-6, -8 or -10 joist lumber; or one ply of 4-by-6, -8 or -10 joist lumber. The hangers are fabricated from No. 12 gage [ inch (2.66 mm) base-metal thickness], ASTM A 653, SS Grade 33, galvanized steel. The hangers are 3 7 / 16 inches, 3 5 / 8 inches or 5 1 / 8 inches (87 mm, 92 mm or 130 mm) in width and are 4 inches (102 mm) in depth, with varying heights. The hanger is prepunched to accept 16d common nails, for attachment of hangers to joists and headers, as shown in Figure 24. The nails are driven through the joists at a maximum angle of 45 degrees toward the header so that the nails penetrate a minimum of 1 inch (25.4 mm) through the corner of the joist into the header. The joist is to butt up to within 1 / 8 inch (3.2 mm) of the header. See Figure 24 for installation details, and Table 24 for nailing schedules, dimensions, and allowable loads Materials: Steel: All connectors listed in this report are manufactured from ASTM A 653, SS Grade 33, galvanized steel, having a minimum yield strength of 33 ksi (228 MPa) and minimum tensile strength of 45 ksi (310 MPa), unless otherwise noted. The galvanized coating conforms to ASTM A 924/A 924M and A 653, with a G60 coating designation. The uncoated minimum steel thickness of cold-formed steel products, described in Sections 2.1 through 2.24 of this report, shall not, at any location except at bends and corners, be less than 95 percent of the listed base-metal thickness Wood: Wood elements must be nominaldimensional lumber with dimensions consistent with those of the connectors listed in this report, unless otherwise noted. The lumber must have a minimum specific gravity of 0.50, such as Douglas fir larch, and must have a moisture content not exceeding 19 percent. Glue-laminated timber must be comprised of Douglas fir or Southern pine wood species Fasteners: Nails: Nails used with the United Steel Products Company products described in this report must comply with Federal Specification FF-N-105B or ASTM F , and must have the properties shown in Table 25. Fasteners for pressure-preservative-treated wood must be of hot-dipped, zinc-coated galvanized stainless steel, silicon bronze or copper. Fasteners required to be corrosionresistant must be either zinc-coated fasteners or stainless steel fasteners Bolts: Bolts must comply with ASTM A 307, with a minimum bending yield strength, F yb, of 36,000 psi (310 MPa) Lag Screws: The lag screws must conform to ANSI/ASME B18.2.1, and must have a minimum bending yield strength, F yb, of 70,000 psi (483 MPa) Design: The connected wood members must be designed to resist the applied loads. The allowable loads for the connectors described in this report are based on the lowest load obtained by comparing the following: 1. Lowest test load that causes a deflection of 1 / 8 inch (3.2 mm). 2. Lowest ultimate test load divided by a safety factor of Allowable fastener and/or compression-perpendicular-tograin values set forth in Chapter 23, Division III, of the 1997 Uniform Building Code (UBC), or Section 2306 of the 2000 International Building Code (IBC), whichever code is applicable, based on wood with a specific gravity of 0.50, such as Douglas fir larch. Allowable loads for the connectors described in this report are for connectors used with wood seasoned to a moisture content of 19 percent or less, and used under continuously dry conditions and where sustained temperatures are 100 F (37.7 C) or less. For connectors used with unseasoned or partially seasoned wood, or when the connectors are exposed to wet service conditions, the allowable loads listed in the report must be multiplied by the moisture content factor (C m ) as specified by Part VII of the revised 1991 edition of, and the supplement to, the ANSI/NFoPA NDS-91 National Design Specification for Wood Construction (NDS), as cited in the UBC; and specified by Part VII of the 1997 edition of and supplement to the ANSI/AF&PA NDS-97 National Design Specification for Wood Construction (NDS), as cited in the IBC and the 2000 International Residential Code (IRC).

11 Page 4 of Installation: The connectors are installed in accordance with this report and the manufacturer s installation instructions. The manufacturer s installation instructions must be strictly adhered to, and copies must be available on the jobsite at all times during installation Identification: Each connector described in this report is identified by a stamp or label bearing the manufacturer s name (United Steel Products Company) and/or the USP trademark; the model number; and the evaluation report number (ICBO ES ER- 2039). 3.0 EVIDENCE SUBMITTED Descriptive literature, calculations, and load test reports in accordance with the ICBO ES Acceptance Criteria for Joist Hangers and Similar Devices (AC13), dated January FINDINGS That the USP connectors described in this report comply with the 1997 Uniform Building Code (UBC), the 2000 International Building Code (IBC), and the 2000 International Residential Code (IRC), subject to the following conditions: 4.1 The connectors are manufactured, identified, and installed in accordance with this report and the manufacturer s installation instructions. 4.2 Maximum allowable loads comply with this report, and do not exceed the loads published in Tables 1 through Unless otherwise noted, lumber is nominaldimension lumber having a minimum specific gravity of 0.50, with a moisture content of 19 percent of less, used under continuously dry conditions. 4.4 Adjustment factors noted for wet service conditions, elevated temperatures and pressure-treated wood must be considered when applicable. Fasteners in pressure-treated wood must comply with Section of this report. 4.5 For connectors embedded in concrete, the minimum concrete compressive strength is 2,000 psi (13.9 MPa) at 28 days, unless otherwise noted. 4.6 Calculations showing compliance with this report are submitted to the building official for approval. 4.7 Use of the connectors is limited to lumber that has not been treated with fire-retardant chemicals. This report is subject to re-examination in two years.

12 Page 5 of 30

13 Page 6 of 30

14 Page 7 of 30

15 Page 8 of 30

16 Page 9 of 30

17 Page 10 of 30

18 Page 11 of 30

19 Page 12 of 30

20 Page 13 of 30

21 Page 14 of 30

22 Page 15 of 30

23 Page 16 of 30

24 Page 17 of 30

25 Page 18 of 30

26 Page 19 of 30

27

28 Page 20 of 30

29 Page 21 of 30

30 Page 22 of 30

31 Page 23 of 30

32 Page 24 of 30

33 Page 25 of 30

34 Page 26 of 30

35 Page 27 of 30

36 Page 28 of 30

37 Page 29 of 30

38 Page 30 of 30

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS JAVIER NUÑEZ PRESIDENT MARSHA L. BROWN VICE-PRESIDENT VAN AMBATIELOS PEDRO BIRBA ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report www.icc-es.org (800) -6587 (56) 699-05 ESR-0 Reissued March, 0 This report is subject to renewal in two years. A Subsidiary of the International Code Council DIVISION: 06 00 00

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16 ER-5736 Reissued September 1, 2002 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: FASTENERS Wood Hangers and Framing Anchors USP LUMBER

More information

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

ESR-1254 * DELETED BY CITY OF LOS ANGELES.   Reissued April 1, 2006 This report is subject to re-examination in one year. ESR-1254 Reissued April 1, 2006 This report is subject to re-examination in one year. www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2608 Reissued January 2016 This report is subject to renewal January 2017. A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 87 () 99 0 www.icc es.org ESR 9 Reissued 0/08 This report is subject to renewal 0/09. DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

*Revised September 1, 2003

*Revised September 1, 2003 LEGACY REPORT ER-580* Reissued January, 00 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 560 Workman Mill Road, Whittier, California 9060 # (56) 699-054 Regional Office # 900 Montclair

More information

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3072 Reissued 09/2018 Revised 10/2018 This report is subject to renewal 09/2020.

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-6 Reissued April, 009 This report is subject to re-examination in two years. www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 87 () 99 0 www.icc es.org ESR Reissued 0/07 This report is subject to renewal 0/08. DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT: 0 ICC ES Evaluation Report ICC ES 000 (800) 687 (6) 699 0 www.icc es.org Most Widely Accepted and Trusted ESR Reissued 0/08 This report is subject to renewal 0/00. DIVISION: 06 00 00 WOOD, PLASTICS AND

More information

(800) (562) A Subsidiary of the International Code Council

(800) (562) A Subsidiary of the International Code Council ICC-ES Evaluation Report ESR-65 Issued October, 009 This report is subject to re-examination in two years. www.icc-es.org (800) -6587 (56) 699-05 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3768 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 06 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3096 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 06 00 00 WOOD, PLASTICS

More information

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (800) 42-658 (562) 699-054 ESR-99* Reissued June, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION: 0 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2761 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 06 00

More information

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

LEGACY REPORT.  (800) (562) A Subsidiary of the International Code Council. *Revised September 2003 ICC-ES Evaluation Report ER-580* Reissued January 00 www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council Legacy report on the 997 Uniform Building Code DIVISION: 05

More information

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 42-6587 (562) 699-054 ESR-799 Reissued April 204 This report is subject to renewal June, 205. A Subsidiary of the International Code Council DIVISION: 0 00

More information

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners. DESIGN NOTES 1) Allowable loads for more than one direction for a single connection cannot be added together. A design load which can be divided into components in the directions given must be evaluated

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-2909 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3507 Reissued 03/2018 This report is subject to renewal 03/2020. DIVISION: 06 00

More information

ESR-1799 Reissued June 1, 2009 This report is subject to re-examination in one year.

ESR-1799 Reissued June 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-799 Reissued June, 009 This report is subject to re-examination in one year. www.icc-es.org (800) -87 () 99-0 A Subsidiary of the International Code Council DIVISION: 0CONCRETE

More information

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013.

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013. ICC-ES Evaluation Report ESR-2024* Reissued September, 20 This report is subject to renewal September, 20. www.icc-es.org (800) 42-68 (62) 699-04 A Subsidiary of the International Code Council DIVISION:

More information

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019 SUNMODO CORPORATION 14800 NE 65 th Street Vancouver, WA 98682 SUNMODO EZ ROOF MOUNT L-FOOT KITS FOR SHINGLE ROOFS CSI Section: 06 25 23 Wood, Plastic, and Composite Fastenings 07 71 00-Roof Specialties

More information

Originally Issued: 06/28/2012 Revised: 06/21/2017 Valid Through: 06/30/ Design

Originally Issued: 06/28/2012 Revised: 06/21/2017 Valid Through: 06/30/ Design EVALUATION SUBJECT: SIMPSON STRONG-DRIVE SDWC WOOD SCREWS REPORT HOLDER: Simpson Strong-Tie Company Inc. 5956 West Las Positas Boulevard Pleasanton, California 94588 (800) 999-5099 www.strongtie.com CSI

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.org ESR 2442 Reissued 0/208 This report is subject to renewal 0/209. DIVISION: 06 00 00 WOOD,

More information

3.1 General Provisions

3.1 General Provisions WOOD FRAME CONSTRUCTION MANUAL 107 3.1 General Provisions 3.1.1 Prescriptive Requirements The provisions of this Chapter establish a specific set of resistance requirements for buildings meeting the scope

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2442 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 06 00

More information

A. Rough carpentry includes but is not limited to the following:

A. Rough carpentry includes but is not limited to the following: SECTION 06100 ROUGH CARPENTRY PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification Sections,

More information

THE ENGINEERED WOOD ASSOCIATION

THE ENGINEERED WOOD ASSOCIATION D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

Load Tables, Technical Data and Installation Instructions

Load Tables, Technical Data and Installation Instructions W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting

More information

Submittal / Substitution Request

Submittal / Substitution Request Submittal / Substitution Request SUBMITTED TO: To: Firm: Project: Submitted Product: SIMPSON STRONG-TIE POWDER ACTUATED FASTENERS Specified Product: Section: Page: Detail/Sheet : Description of Application:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3654 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

Wood Connections. Concepts of Well Designed Connections

Wood Connections. Concepts of Well Designed Connections Wood Connections Sam Hensen, P.E. Branch Engineering Manager Concepts of Well Designed Connections Must provide sufficient capacity to transfer loads to supporting members Utilize fastener spacing which

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3042 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00

More information

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply

More information

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014. ICC-ES Evaluation Report www.icc-es.org (800) -687 (6) 699-0 ESR-0* Reissued August, 0 This report is subject to renewal September, 0. A Subsidiary of the International Code Council DIVISION: 06 00 00

More information

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3201 Reissued 07/2018 This report is subject to renewal 07/2019. DIVISION: 06 00

More information

APA Performance Rated Rim Boards

APA Performance Rated Rim Boards D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3870 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 05 00

More information

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2024 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00

More information

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-403 Reissued October, 009 This report is subject to re-examination in one year. www.icc-es.org (800) 43-6587 (56) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 279 Reissued 08/2018 This report is subject to renewal 08/2020. DIVISION: 0 00 00 CONCRETE

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3164 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

TER No Use of FastenMaster TimberLOK Fasteners to Provide Uplift & Lateral Resistance to Trusses & Rafters Attached to the Tops of Walls

TER No Use of FastenMaster TimberLOK Fasteners to Provide Uplift & Lateral Resistance to Trusses & Rafters Attached to the Tops of Walls Use of FastenMaster TimberLOK Fasteners to Provide Uplift & Lateral Resistance to Trusses & Rafters Attached to the Tops of Walls OMG, Inc. d/b/a/ FastenMaster 153 Bowles Road Agawam, MA 01001 413-789-0252

More information

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015.

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 4-6587 (56) 699-054 ESR-7* Reissued September, 0 This report is subject to renewal July, 05. A Subsidiary of the International Code Council DIVISION: 05 00

More information

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1360 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report www.icc-es.org (800) -68 (6) 699-0 ESR-8* Reissued March, 0 This report is subject to renewal in two years. A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE

More information

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings (see Section

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products March 2002 2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS The 2001 Edition of the National Design Specification

More information

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2

More information

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3098 Issued February 1, 2011 This report is subject to re-examination in one year. A Subsidiary of the International Code Council

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

Featuring TJ Rim Board and TimberStrand LSL

Featuring TJ Rim Board and TimberStrand LSL #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load

More information

SDWH TIMBER-HEX Screw

SDWH TIMBER-HEX Screw Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections, Including Ledgers Double-barrier coating provides corrosion resistance equivalent to hot-dip galvanization, making it suitable

More information

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2961 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 05 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS SECTION: STAPLES REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS SECTION: STAPLES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (56) 699 054 www.icc es.org ESR 159 Reissued 07/018 This report is subject to renewal 07/00. DIVISION: 06 00 00 WOOD,

More information

Glulam Connection Details

Glulam Connection Details T E C H N I C A L N O T E Glulam Connection Details Note: This version is superseded by a more current edition. Check the current edition for updated design and application recommendations. ENGINEERED

More information

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3528 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016 Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder Installation Instructions Revised 9/2/2016 SBCA has been the voice of the structural building components industry

More information

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1790 Reissued September 1, 2012 This report is subject to renewal September 1, 2013. A Subsidiary of the International Code Council

More information

DIVISION 6 WOOD AND PLASTICS

DIVISION 6 WOOD AND PLASTICS DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.

More information

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016 Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016 SBCA has been the voice of the structural building components industry since 1983, providing

More information

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar. Outline ASD and LRFD with the 2005 NDS Part 2 Connection Design Presented by: John Buddy Showalter, P.E. Vice President, Technology Transfer Connection philosophy p NDS Chapter-by-chapter description Changes

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1754 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance Typical Deck Details Based on the City of Nixa Residential Deck Ordinance The use of this package in lieu of submitted drawings applies to Single Span, Single Level, Residential Decks ONLY. Decks must

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 03 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 06 00 00 WOOD, PLASTICS

More information

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT [March 25, 2015] Malarkey recently received our new, updated ICC ES Evaluation Report (ESR 3150) which includes the additions of Windsor shingles and all

More information

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475 ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475 Product Evaluation Updated: 4/08 Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer ESR-1475 Reissued April 1,

More information

SECTION ROUGH CARPENTRY

SECTION ROUGH CARPENTRY SECTION 06 10 00- ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Contracting Requirements and Division 1 Specification Sections, apply

More information

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 4185 Issued 06/2018 This report is subject to renewal 06/2019. SECTION: 05 05 23

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1754 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later Lateral Support Decks over 24 above grade require lateral support* *Exceptions to be discussed later Decking Types of Decking: -2x4s & 2x6s -five quarter span rated decking boards -Wood plastic composite

More information

Connection Design Examples

Connection Design Examples Connection Design Examples Using the 2015 NDS (DES345) Lori Koch, P.E. Manager, Educational Outreach American Wood Council Adam Robertson, M.A.Sc., P.Eng. Manager, Codes and Standards Canadian Wood Council

More information

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE U.S. Technical Guide U.S. TECHNICAL GUIDE LP SolidStart LVL & Header Technical Guide 2900F b -2.0E Please verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior

More information

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 06 1053 - MISCELLANEOUS ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Division 01 Specification

More information

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

TYPICAL PATIO COVERS.  OWNER: ADDRESS: PHONE: City of Aliso Viejo Building Division 12 Journey, Suite 100 Aliso Viejo, CA 92656 (949)425-2540 Fax (949)425-3899 www.cityofalisoviejo.com TYPICAL PATIO COVERS 111 I. GENERAL Patio covers are one-story,

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3564 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: TOBIN STEEL COMPANY, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: TOBIN STEEL COMPANY, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (56) 699 054 www.icc es.org ESR 8 Reissued 07/07 This report is subject to renewal 07/08. DIVISION: 06 00 00 WOOD, PLASTICS

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-87 (2) 99-043 www.icc-es.org ESR-3332 Reissued 09/207 This report is subject to renewal 09/208. DIVISION: 0 00 00 METALS

More information

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: TREE ISLAND INDUSTRIES, LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: TREE ISLAND INDUSTRIES, LTD. 0 Most Widely Accepted and Trusted ICC-E Evaluation Report ICC-E 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ER-1768 Reissued 08/2017 This report is subject to renewal 08/2018. DIVIION: 06 00 00 WOOD,

More information

Nails, Fasteners, Connectors, and Framing

Nails, Fasteners, Connectors, and Framing Nails, Fasteners, Connectors, and Framing Nails To order Nail Sizes Nail length is often referred to as d or penny. For example a 10-D nail or a 10 Penny Nail. Use the following chart for nail length reference.

More information

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A SECTION 061050 - MISCELLANEOUS CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

City of Virginia Beach, Virginia Typical Deck Details

City of Virginia Beach, Virginia Typical Deck Details City of Virginia Beach, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1717 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3532 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00 00 THERMAL

More information

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January

More information

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2

More information

Typical Deck Details

Typical Deck Details Based on the 2009 Michigan Statewide Building Code guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachement to existing house s footing beam

More information

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load capacity of 2x

More information

Typical Deck Details

Typical Deck Details Botetourt County guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachment to existing house s footing beam -to-beam connection post-to-beam connection

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: OMG, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: OMG, INC. 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-1078 Reissued 01/2018 Revised 09/2018 This report is subject to renewal 01/2019 DIVISION:

More information

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK: SECTION 061000 - ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK: A. Definition: Rough carpentry includes carpent~y work not specified as part of other sections and which is generally not exposed, except as otherwise

More information