Voltage regulator TAPCON 240

Size: px
Start display at page:

Download "Voltage regulator TAPCON 240"

Transcription

1 Voltage regulator TAPCON 240 Supplement /00 Protocol description for IEC

2 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and communication of its contents are strictly prohibited unless expressly authorized. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. The product may have been modified after this document went to press. We expressly reserve the right to make changes to the technical data, the design or the scope of delivery. Generally, the information provided and the arrangements agreed during processing of the relevant quotations and orders are binding. The original operating instructions were drawn up in German.

3 Table of Contents Table of Contents 1 General notes About this document Information about the standard Abbreviations used Voltage regulator connections Settings on the voltage regulator Communication interface RS Communication interface RS Fiber-optic cable (optional) Data points Message structure Function types Type codes Data types Monitoring direction General commands in monitoring direction Signals at the digital input terminals Generic data in monitoring direction Control direction System functions General data in control direction Generic data in control direction Maschinenfabrik Reinhausen /00 EN TAPCON 240 3

4 Table of Contents 5 Sample sequences Time synchronization General query General command General query, generic data Generic command (write entry with version) Tap position telegram Structure of telegram Examples of messages for tap position telegrams Setting time and date settings TAPCON /00 EN Maschinenfabrik Reinhausen 2010

5 1 General notes 1 General notes 1.1 About this document This document describes implementation of the interface protocol IEC for the TAPCON 240. Read this description along with the technical file for the TAPCON Information about the standard The <Communication protocol> interface protocol was originally developed for communication between protective devices. The pre-defined function types and associated information numbers are not suitable for the information that the voltage regulator has to transfer. A function type from the "private sphere" of the protocol is therefore used for all "non-generic data points". The information numbers for all general commands and messages with the function type from the "private sphere" are specific. Analog values are transferred in the control direction (command) and monitoring direction (message) using a generic message type. All measured values are assigned to class 2 and all parameters to class 1. In addition to the 9.6 and 19.2 kilobaud rates required by the standard, baud rates of 38.4 and 57.6 kilobauds can also be selected on the voltage regulator. Maschinenfabrik Reinhausen /00 EN TAPCON 240 5

6 1 General notes 1.3 Abbreviations used Abbreviation Definition ASDU Application Service Data Unit BCD Binary Coded Decimal CIC Communication Interface Card GQ General query GPI General Purpose Input GPO General Purpose Output Fiber-optic cable Fiber-optic cable MR Maschinenfabrik Reinhausen RTC Real Time Clock TAPCON trol PC software for displaying regulator data Table 1 Abbreviations 6 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

7 2 Voltage regulator connections 2 Voltage regulator connections The physical interfaces RS232, RS485 and optional fiber-optic cables are provided on the voltage regulator for data transfer via the IEC protocol. Figure 1 CIC card 1 RS232 (9 pin female SUB-D connector) 2 RS485 3 Ethernet RJ45 (optional) 4 FH-ST or F-SMA fiber-optic cable in 850 nm or 660 nm (optional) 5 Reset key 6 TxD LED for transmit signal 7 RxD LED for receive signal 8 Clk LED for operating mode (flashes for 2 seconds) 9 Clip for connecting cable shield with functional ground Maschinenfabrik Reinhausen /00 EN TAPCON 240 7

8 2 Voltage regulator connections RS232 RS485 Fiber-optic cable (optional) 9 pin female SUB-D connector Pin 2: TxD Pin 3: RxD Pin 5: GND 3 pin connector from Phoenix (MC1.5/3 GF 3.5) Pin 1: GND (100 Ω ground resistance) Pin 2: B (inverted) Pin 3: A (not inverted) Polarity: A > B by 200 mv corresponds to 1. A < B by 200 mv corresponds to 0. An interrupted communication line corresponds to 1. The start bit has the designation 0. Recommended terminating resistor 120 Ω. FH-ST (850 nm or 660 nm) F-SMA (850 nm or 660 nm) Table 2 Interfaces available Transfer on physical plane: Asynchronous with 8 data bits, even parity, 1 stop bit (8E1) 8 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

9 3 Settings on the voltage regulator 3 Settings on the voltage regulator The following chapters describe how to set the parameters for communication at the relevant interface on the TAPCON 240. > Configuration > Next* > Comm. interface Depending on the product version and software, you will need to press "Next" a varying number of times to reach the "Comm. interface" menu. You will find more information on how to set the parameters in the technical file for TAPCON Communication interface RS232 Communication interface Baud rate communication Fiber-optic cable light ON/OFF Local SCADA address RS /19.2/38.4/57.6 kilobaud not used (0 = Broadcast message) Send delay time ms* Table 3 Interface settings RS232 Maschinenfabrik Reinhausen /00 EN TAPCON 240 9

10 3 Settings on the voltage regulator 3.2 Communication interface RS485 Communication interface Baud rate communication Fiber-optic cable light ON/OFF Local SCADA address RS /19.2/38.4/57.6 kilobaud not used (255 = Broadcast message) Send delay time ms* Table 4 Interface settings RS485 *) e.g 2 ms, in order to compensate for the response time of an external converter RS485/RS232 when switching between transmit and receive operation. 3.3 Fiber-optic cable (optional) Communication interface Baud rate communication Fiber-optic cable light ON/OFF Local SCADA address Fiber-optic cable 9.6/19.2/38.4/57.6 kilobaud ON (1 corresponds to light On) or OFF (1 corresponds to light Off) (255 = Broadcast message) Send delay time Table 5 not used Interface settings Fiber-optic cable In addition to the 9.6 and 19.2 kilobaud rates required by the standard, baud rates of 38.4 and 57.6 kilobauds can also be selected on the voltage regulator. 10 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

11 4 Data points 4 Data points 4.1 Message structure The function types, type codes and data types which are listed in the data tables are explained below Function types Type codes Data types 110 = function type from the private sphere (can be defined specifically) 254 = generic function type 255 = global function type 1 = message with time stamp 6 = time synchronization 7 = general query 10 = generic data 20 = general command 21 = generic command 7 = short real Maschinenfabrik Reinhausen /00 EN TAPCON

12 4 Data points 4.2 Monitoring direction All spontaneous messages (in the event of changes) are transmitted with a time stamp. The time stamp always relates to when the message is sent. A message caused by a general query is sent without a time stamp General commands in monitoring direction Type code Info no. Byte 2 Info no. Byte 1 Class Description Auto/manual (On = auto mode; Off = manual mode) Desired voltage value 1 On Desired voltage value 2 On Desired voltage value 3 On SI command 1 active* SI command 2 active* SI command 3 active* Motor-drive unit running Messages which can be parameterized: The TAP- CON 240 has 4 messages which can be parameterized. These can be put on an input or relay. The messages are ON when there is a signal at the parameterized input or the parameterized relay is activated Message no Message no Message no Message no Parallel operation On Parallel operation is only active when all conditions for parallel operation are met Master parallel operation method On (feedback) Follower parallel operation method On (feedback) Circulating reactive current parallel operation method On (feedback) Parallel operation error Voltage regulator error ON when recording a parameterization error. 12 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

13 4 Data points Type code Info no. Byte 2 Info no. Byte 1 Class Description Tap position This is an alternative way of recording the tap position. The value is the same as under GIN LSB 54 and GIN MSB 2. Tap position This is another way for the control system to record the tap position. The value is the same as for the other tap position telegrams. Function monitoring (a control deviation has existed for 15 minutes) Local/Remote (On = Remote; Off = Local) Overvoltage V> Undervoltage V< Overcurrent I> Table 6 Data points in monitoring direction Maschinenfabrik Reinhausen /00 EN TAPCON

14 4 Data points Signals at the digital input terminals Most signals can be transferred to the SCADA system via the digital input terminals. When triggered, the interface addresses to the corresponding inputs behave as follows: Type code Info no. Byte 2 Info no. Byte 1 Class Description Card type Specification for hardware version I Specification for hardware version III IO X1/z20 X1/ IO X1/d20 X1/ UC1 X1/d30 X1/ UC1 X1/b30 X1/ UC1 X1/d28 X1/ UC1 X1/b28 X1/ UC1 X1/d26 X1/ UC1 X1/b26 X1/ UC1 X1/d24 X1/ UC1 X1/b24 X1/ UC1 X1/d22 X1/ UC1 X1/b22 X1/ UC2 X2/d30 X2/ UC2 X2/b30 X2/ UC2 X2/d28 X2/ UC2 X2/b28 X2/ UC2 X2/d26 X2/ UC2 X2/b26 X2/ UC2 X2/d24 X2/ UC2 X2/b24 X2/ UC2 X2/d22 X2/ UC2 X2/b22 X2/12 Table 7 Signals at the digital input terminals 14 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

15 4 Data points Generic data in monitoring direction Type code Function type GIN LSB GIN MSB Data type Class Description Tap position Set values Since the set values are transferred as the "Short real" data type, deviations may arise between the set value and the value transferred via the interface if the set value cannot be depicted accurately as a "Short real" value Desired voltage value Actual voltage Deviation Active current Reactive current Apparent current Table 8 Generic data in monitoring direction 4.3 Control direction For commands from the control system to be executed on the Monitoring system, Remote mode must be set System functions Type code Description 7 Start of general query 6 Time synchronization 21 Start of general query for generic data Table 9 System functions A message to indicate the end of the general query follows the last info message for the GQ cycle. Maschinenfabrik Reinhausen /00 EN TAPCON

16 4 Data points General data in control direction Type code Info no. Byte 2 Info no. Byte 1 Class Description Auto/manual (On = auto mode; Off = manual mode) Raise (On = raise; Off = lower; only in manual mode) Lower (On = lower, Off = no function; only during manual mode) Raise/lower desired voltage value This function is optional. Parameterization is undertaken by MR. The desired voltage value function 1/2/3 is possible under the following conditions: - no inputs parameterized for selecting desired voltage values 2 and 3 - raise/lower desired voltage value function not parameterized Parameterization is undertaken by MR Desired voltage value Desired voltage value Desired voltage value 3 Each SI command sets a flag in the TAPCON 240. The status of the flags can be used like an input for the I/O or UC modules to activate or deactivate a TAPCON 240 function. Example: If the "Parallel group input" parameter is set to "SI:cmd1" for two TAPCON 240, parallel control for these TAPCON 240 can be activated or deactivated by setting the "SI command 1" on/off command for both TAPCON SI command SI command SI command Parallel operation (On = activate circulating reactive current parallel operation, Off = deactivate parallel operation) Master parallel operation method (On = activate master parallel operation mode, Off = activate "Automatic synchronization" parallel operation mode) Follower parallel operation method (On = activate follower parallel operation mode) Table 10 General data in control direction The voltage regulator returns the command received with reason for transmission 20 if the message has been accepted. 16 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

17 4 Data points The voltage regulator can only process generic commands with one data set per message Generic data in control direction Type code Function type GIN LSB GIN MSB Data type Class Description Voltage level Table 11 Generic data in control direction Maschinenfabrik Reinhausen /00 EN TAPCON

18

19 5 Sample sequences 5 Sample sequences 5.1 Time synchronization Sample command for time synchronization: 68 f f ff f Code (hexadecimal) Definition 68 f f Start message 6 Type code = 6 (decimal) = Time synchronization command 8 Reason for transmission = 8 = Time synchronization ff Function type = 255 = Global function type 0 Info number (or address of information object 2nd octet) = 0 = Time synchronization 9 2f Time structure CP56Time2a End message Figure 2 Sample command for time synchronization After time synchronization, the voltage regulator returns the time synchronization feedback as positive confirmation. The reason for transmission is set to 8. These time details are only used for display purposes in the TAPCON trol visualization software; internally the regulator uses a continuous RTC. The time stamp in the regulator's telegrams is produced by the communication card and is only set when the telegram is sent. Maschinenfabrik Reinhausen /00 EN TAPCON

20 5 Sample sequences 5.2 General query Sample command for general query (GQ): ff 0 0 d5 16 Code (hexadecimal) Definition Start message 7 Typ code = 7 (decimal) = General query 9 Reason for transmission = 0 = not used Function type (or address of information object 1st ff octet) = 255 = Global function type Info number (or address of information object 2nd octet) = 0 0 d5 16 End message Figure 3 Sample command for general query (GQ) After the last data message from the general query cycle, the "GQ complete" message is issued with type code 8 and reason for transmission TAPCON /00 EN Maschinenfabrik Reinhausen 2010

21 5 Sample sequences 5.3 General command Example of general command: 68 a a ff 0 0 d5 16 Code (hexadecimal) Definition 68 a a Start message 14 Typ code = 20 (decimal) = General command 14 Reason for transmission = 20 (decimal) = General command 6e Function type = 110 (decimal) = Private sphere 10 Info number (or address of information object 2nd octet) = 16 (decimal) = Auto/Manual 1 Value = OFF 6d 16 End message Figure 4 Example of general command Once it has received a valid command, the voltage regulator returns the command message as positive confirmation. The reason for transmission is set to 20. Maschinenfabrik Reinhausen /00 EN TAPCON

22 5 Sample sequences 5.4 General query, generic data Sample command for general query, generic data: 68 a a fe f5 0 0 d7 16 Code (hexadecimal) Definition 68 a a Start message 15 Type code = 21 (decimal) = General query 9 Reason for transmission = 9 = not used fe Function type (or address of information object 1st octet = 254 (decimal) = Generic funktion type f5 Info number (or address of information object 2nd octet) = 245 (decimal) = General query, generic data d7 16 End message Figure 5 Sample command for general query, generic data After the last data transfer for the "General query", a message entitled "GQ complete" is transferred with type code 10, info number 245 and reason for transmission TAPCON /00 EN Maschinenfabrik Reinhausen 2010

23 5 Sample sequences 5.5 Generic command (write entry with version) Example of generic command (write entry with version): a fe fa ca Code (hexadecimal) Definition Start message a Type code = 10 (decimal) = Generic Data 28 Reason for transmission = 40 = Generic write command fe Function type (or address of information object 1st octet) = 254 (decimal) = Generic function type fa Info number (or address of information object 2nd octet) = 250 (decimal) = Write entry 37 1 GIN LSB = 55 (decimal), GIN MSB = 1; 55 = Desired volatge value 1 7 Data type = 7 = Short real 0 0 ca 42 4 bytes of data End message Figure 6 Example of generic command (write entry with version) Once it has received a valid command, the voltage regulator returns the command message as positive confirmation. The reason for transmission is set to 40. If the command cannot be performed, the reason for transmission is 41. The generic command "Write entry with confirmation" (info number 249) is not implemented. Maschinenfabrik Reinhausen /00 EN TAPCON

24

25 6 Tap position telegram 6 Tap position telegram 6.1 Structure of telegram The structure of the individual telegrams is described in the tables below. Message type Variable structure code Reason for transmission Shared address of ASDU Function type Information number RII NGD GIN LSB GIN MSB KOD Data type Number of data bytes Quantity 10 0x81 1 or 9 Address set For tap position 54 For tap position message (short real) 4 1 Data (4 bytes, short real) Table 12 Structure of type 10 telegram Maschinenfabrik Reinhausen /00 EN TAPCON

26 6 Tap position telegram Message type Variable structure code Reason for transmission Shared address of ASDU Function type Information number Data (4 bytes, short real) Relative time ms (2 bytes) Error number (2 bytes) 4 0x81 1 or 9 Address set 110 For tap position message 118 Tap position not used, always 0 not used, always 0 Time (2 bytes) Table 13 Structure of type 4 telegram Message type Variable structure code Reason for transmission Shared address of ASDU Function type Information number 204 0x81 1 or 9 Address set 110 For tap position 54 Tap position Data (4 bytes, short real) Time (4 bytes) SIN (1 byte) Table 14 Structure of type 204 telegram 26 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

27 6 Tap position telegram 6.2 Examples of messages for tap position telegrams The examples were taken from various log files which recorded the telegram traffic between a PC and the voltage regulator. The voltage regulator address was set to 1. Some of the tap positions in the sample telegrams selected are different in order to show examples with different values. The same tap position is normally reported in all three telegrams. Telegram Comments ff 0 0 d5 16 General query command from PC 68 a a fe f5 0 0 d7 16 General query command for generic data from PC e f3 9b 82 0 d a fe f d cc e c d e f fd a4 27 8b a a fe f f ad cc e d5 27 8b 0 db 16 Table 15 Type 4 telegram, sent during general query Type 10 telegram, sent during general query Tap position 0 is reported in bytes Type 204 telegram, sent during general query Tap position 0 is reported in bytes Type 4 telegram, sent due to a change in tap position Tap position 1 is reported in bytes f Type 10 telegram, sent due to a change in tap position Tap position 1 is reported in bytes f Type 204 telegram, sent due to a change in tap position Tap position 2 is reported in bytes Examples of messages for tap position message telegram Maschinenfabrik Reinhausen /00 EN TAPCON

28 6 Tap position telegram 6.3 Setting time and date settings The TAPCON 240 has a counter module which counts the number of seconds after the supply voltage fails. Its supply is buffered by a large capacitor such that it continues to count for at least a few days even if the TAP- CON 240 is switched off. The time and date are set using an offset value which is converted into the time and date displayed in the measured value plotter screen along with the current counter reading. The interface software sends the time and date from the IEC103 time synchronization telegram to the actual CPU with the regulator firmware. The regulator firmware uses this information to calculate the new offset value to display for time and date in the measured value plotter screen. The counter in the TAPCON 240 counts whole seconds. Because the figures are rounded up or down, the time displayed in the measured value plotter screen may deviate from the time in the time synchronization telegram. The TAPCON 240's time and date will only be set from the control system's time synchronization telegram if both the interface software and firmware in the regulator support this. The telegrams' time stamp at the interface is not affected by the setting for the time displayed by the TAPCON 240. This time stamp is produced locally on the CIC card itself. 28 TAPCON /00 EN Maschinenfabrik Reinhausen 2010

29

30 /00 EN 12/10 Maschinenfabrik Reinhausen GmbH Falkensteinstrasse Regensburg Phone: Fax: sales@reinhausen.com

Voltage regulator TAPCON 260

Voltage regulator TAPCON 260 Voltage regulator TAPCON 260 Supplement 2531975/00 Protocol description for IEC 60870-5-103 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and

More information

Voltage Regulator TAPCON 230 basic. Quick reference guide /02

Voltage Regulator TAPCON 230 basic. Quick reference guide /02 Voltage Regulator TAPCON 230 basic Quick reference guide 2117248/02 2012 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and the utilization and communication

More information

Voltage Regulator TAPCON 260

Voltage Regulator TAPCON 260 Voltage Regulator TAPCON 260 Operating Instructions 2451172/03 EN. Three-winding transformer with IEC 61850 All rights reserved by Maschinenfabrik Reinhausen Dissemination and reproduction of this document

More information

MPS PROFIBUS-DP INTERFACE

MPS PROFIBUS-DP INTERFACE 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/protectionrelays MPS PROFIBUS-DP INTERFACE PRELIMINARY SEPTEMBER 8, 2003 Publication: PROFIBUS-M

More information

745 Transformer Protection System Communications Guide

745 Transformer Protection System Communications Guide Digital Energy Multilin 745 Transformer Protection System Communications Guide 745 revision: 5.20 GE publication code: GEK-106636E GE Multilin part number: 1601-0162-A6 Copyright 2010 GE Multilin GE Multilin

More information

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8 Application Note of OGM220, AN001 V1.8 1.0 Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO2 concentration. OGM220 is designed for multi-dropped

More information

TAPCON 260 Parallel transformer bank operation

TAPCON 260 Parallel transformer bank operation www.reinhausen.com TAPCON 260 Parallel transformer bank operation Operating Instructions BA 261-001/03 NOTE Changes may have been made to a product after going to press with this documentation. We expressly

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Voltage Regulator TAPCON 240

Voltage Regulator TAPCON 240 www.reinhausen.com Voltage Regulator TAPCON 240 Operating Instructions BA 222/04 Table of Contents Table of Contents 1 General... 4 1.1 Foreword... 4 1.2 Manufacturer... 4 2 Safety... 5 2.1 Safety instructions...

More information

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 013C (013-CCF0R00) Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features SPEED7 technology 16 x DI, 12 x DO, 2 x AI, from which are 4 input channels

More information

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades

More information

Voltage regulator TAPCON 230 basic. Operating Instructions /02

Voltage regulator TAPCON 230 basic. Operating Instructions /02 Voltage regulator TAPCON 230 basic Operating Instructions 2117246/02 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and communication of its

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS Linking computers to the real world WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION General The Model 321BS provides computer readable time and date information based on the United

More information

Parameter Value Unit Notes

Parameter Value Unit Notes Features Single axis measurement from ±5 to ±60 High resolution and accuracy. Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 and RS485 output

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title Appendices 1 (10) Project designation R5 RIC Document title CONTENTS 1 Installation... 2 1.1 Connectors... 2 1.1.1 Power... 2 1.1.2 Video... 2 1.1.3 Sync... 3 1.1.4 RS232/ARP/ACP... 3 1.1.5 Radar data...

More information

Fast Dynamic Parallel Data Interface for the NGD RF Driver

Fast Dynamic Parallel Data Interface for the NGD RF Driver Introduction The NGD series of Acousto-Optic RF Drivers are capable of fast dynamic control of frequency, output power level, and relative phase or delay (Channel #2 relative to Channel #1). The rear panel

More information

WWVB Receiver/Decoder Module With Serial BCD Interface DESCRIPTION FEATURES APPLICATIONS

WWVB Receiver/Decoder Module With Serial BCD Interface DESCRIPTION FEATURES APPLICATIONS Linking computers to the real world WWVB Receiver/Decoder Module With Serial BCD Interface DESCRIPTION General The Model 321BS provides computer readable time and date information based on the United States

More information

Interface Description A2000. Multifunctional Power Meter Communications Protocol per EN /1.15

Interface Description A2000. Multifunctional Power Meter Communications Protocol per EN /1.15 Interface Description A2000 Multifunctional Power Meter Communications Protocol per EN 60870 3-349-128-03 14/1.15 Contents Page 1 Overview of Telegrams (Commands) to the A2000 as per EN 60870... 4 2 Telegram

More information

ELECTRICAL VARIABLE ANALYZER RELAY EVAR

ELECTRICAL VARIABLE ANALYZER RELAY EVAR ELECTRICAL VARIABLE ANALYZER RELAY EVAR 1 ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com

More information

Technical Description

Technical Description Technical Description Radio Clock for IBM PC XT/AT and Compatible 6036 version 04.02 30.08.99 Nottebohmstr. 41 post box 1847 58511 Lüdenscheid 58468 Lüdenscheid fon: 02351 / 938686 fax: 02351 / 459590

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com

More information

Select datum Page backward in. parameter list

Select datum Page backward in. parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

Data sheet CPU 313SC (313-5BF13)

Data sheet CPU 313SC (313-5BF13) Data sheet CPU 313SC (313-5BF13) Technical data Order no. Type 313-5BF13 CPU 313SC General information Note - Features SPEED-Bus - SPEED7 technology 24 x DI, 16 x DO, 4 x AI, 2 x AO, 1 x AI Pt100 128 kb

More information

PHOENIX CONTACT - 03/2007

PHOENIX CONTACT - 03/2007 Inline Function Terminal for Pulse Width Modulation and Frequency Modulation N AUTOMATIONWORX Data Sheet 6920_en_01 1 Description PHOENIX CONTACT - 03/2007 $ ' ) The terminal is designed for use within

More information

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232 control motion interface ELEKTRO-TRADING sp. z o.o Tel. +48 (0-32) 734-55-72 Tel/Fax +48 (0-32) 734-55-70 E-Mail et@elektro-trading.com.pl http://www.elektro-trading.com.pl IP 251 Universal Signal Converter

More information

^3 PMAC2-PCMACRO Interface Board. ^4 3Ax xUxx. ^5 October 23, 2003

^3 PMAC2-PCMACRO Interface Board. ^4 3Ax xUxx. ^5 October 23, 2003 ^1 USER MANUAL ^2 ^3 PMAC2-PCMACRO Interface Board ^4 3Ax-602684-xUxx ^5 October 23, 2003 Single Source Machine Control Power // Flexibility // Ease of Use 21314 Lassen Street Chatsworth, CA 91311 // Tel.

More information

Absolute encoder HE-65

Absolute encoder HE-65 TR - ECE - TI - GB - 00041-01 04/08/2016 SLIN-BUS Absolute encoder HE-65 Technical Information TR-Electronic GmbH D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 email:

More information

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description Home Automation, Inc. Omnistat2 RC-1000 and RC-2000 Communicating Thermostat Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes

More information

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 314ST/DPM (314-6CF02) Data sheet CPU 314ST/DPM (314-6CF02) Technical data Order no. Type 314-6CF02 CPU 314ST/DPM General information Note - Features SPEED-Bus SPEED7 technology, SPEED-Bus 8 x DI, 8 x DIO, 4 x AI, 2 x AO, 1

More information

InsuLogix T MODBUS Protocol Manual

InsuLogix T MODBUS Protocol Manual InsuLogix T MODBUS Protocol Manual Weidmann Technologies Deutschland GmbH Washingtonstraße 16/16a D-01139 Dresden, Germany Telefon: +49 (0)351 8435990 Version 1.1 InsuLogix T MODBUS Protocol Manual 1 Contents

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

InfraStruXure Manager v4.x Addendum: Building Management System Integration

InfraStruXure Manager v4.x Addendum: Building Management System Integration InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System

More information

TAS APFC Controller / Load Managers with MOD-BUS Interface

TAS APFC Controller / Load Managers with MOD-BUS Interface TAS APFC Controller / Load Managers with MOD-BUS Interface Designed & Prepared by TAS PowerTek Pvt. Ltd., W-61, MIDC Ambad, Nasik-422010, India. Updated on: 4th June 2017, Sunday. Data Parameter Field

More information

1M122A Transformer Parallel Control System

1M122A Transformer Parallel Control System Technical Bulletin 1M122A Transformer Parallel Control System Features CONTROL SYSTEM FEATURES Simple system wiring Scaleable up to 4 transformers Flexible control configuration Set transformers in any

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

Chapter 10 Counter modules

Chapter 10 Counter modules Manual VIPA System 00V Chapter 0 Counter modules Chapter 0 Counter modules Overview This chapter contains information on the interfacing and configuration of the SSI-module FM 0 S. The different operating

More information

C Mono Camera Module with UART Interface. User Manual

C Mono Camera Module with UART Interface. User Manual C328-7221 Mono Camera Module with UART Interface User Manual Release Note: 1. 16 Mar, 2009 official released v1.0 C328-7221 Mono Camera Module 1 V1.0 General Description The C328-7221 is VGA camera module

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

PL420 PROGRAMMABLE LOGIC CONTROLLER

PL420 PROGRAMMABLE LOGIC CONTROLLER PL420 PROGRAMMABLE LOGIC CONTROLLER USER MANUAL 12/01/2007 V02 P.O.Box 24 STANFIELD 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com TABLE

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions

More information

MS2711B Hand-Held Spectrum Analyzer

MS2711B Hand-Held Spectrum Analyzer MS2711B Hand-Held Spectrum Analyzer Programming Manual Hand-Held Spectrum Analyzer, for Measuring, Monitoring and Analyzing Signal Environments WARRANTY The Anritsu product(s) listed on the title page

More information

SIMPLY PRECISE PRELIMINARY. Preliminary product overview - LAK encoder. LAK 1 Absolute linear encoder with signal control

SIMPLY PRECISE PRELIMINARY. Preliminary product overview - LAK encoder. LAK 1 Absolute linear encoder with signal control PRELIMINARY Preliminary product overview - LAK encoder LAK 1 Absolute linear encoder with signal control 2 Index 1. Overview 3 2. Applications 3 3. Technical data 4 4. General specifications 5 5. Dimensions

More information

Answering frequently asked Questions (Firmware V.107)

Answering frequently asked Questions (Firmware V.107) FAQ EasyConn Profibus plug Answering frequently asked Questions (Firmware V.107) EasyConn LEDs: While connected, the Profibus connector offers the following test functions for start-up and trouble shooting

More information

Protocol and instruction set for remote control via the infrared interface. Table of Contents

Protocol and instruction set for remote control via the infrared interface. Table of Contents Application information 7 HD mini20 HD 3000 Series HD 4000 Series Protocol and instruction set for remote control via the infrared interface Table of Contents 1 Technical Principles...2 2 Protocol...2

More information

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet VIPA CPU 314SC DPM (314-6CG23) Data sheet VIPA CPU 314SC DPM (314-6CG23) Technical data Order no. Type 314-6CG23 VIPA CPU 314SC DPM General information Note - Features Powered by SPEED7 Work memory [KB]: 512...2.048 Onboard 24x DI /

More information

Manual IF2008A IF2008E

Manual IF2008A IF2008E Manual IF2008A IF2008E PCI Basis Board Expansion Board Table of Content 1 Technical Data... 4 1.1 IF2008A Basic Printed Circuit Board... 4 1.2 IF2008E Expansion Board... 5 2 Hardware... 6 2.1 View IF2008A...

More information

Hardware Guide. Control Made Simple. Model 401A Signal Generator

Hardware Guide. Control Made Simple. Model 401A Signal Generator Control Made Simple Model 401A Signal Generator Hardware Guide ON OFF LIMIT 1 2 3 4 RXD TXD POWER West Coast Office 1263 El Camino Real Menlo Park, CA 94025 Phone (650) 853-1444 Fax (650) 853-1405 www.flashcutcnc.com

More information

Interface Description A2000. Multifunctional Power Meter Communications Protocol per DIN Draft /2.15

Interface Description A2000. Multifunctional Power Meter Communications Protocol per DIN Draft /2.15 Interface Description A2000 Multifunctional Power Meter Communications Protocol per DIN Draft 19244 3-349-125-03 14/2.15 1 Overview of Telegrams (Commands) to the A2000 per DIN Draft 19244...4 2 Telegram

More information

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules Six Differential Current Inputs Six Differential Voltage Inputs USER S MANUAL ACROMAG INCORPORATED Tel: (248) 295-0880 30765

More information

TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface

TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface 11/20/06 TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface BACKGROUND In the early 1960s, a standards committee, known as the Electronic Industries Association (EIA), developed a common serial

More information

Installation Manual ID ISCM01-A/B System delivery contents:

Installation Manual ID ISCM01-A/B System delivery contents: R O B I D i-scan Installation Manual ID ISCM01-A/B antenna test point 1 Cx 1 X2 X1 1 44,0 mm 50,0 mm X3 V100 green V101 red ø 3,3 mm 67,0 mm 75,0 mm System delivery contents: 1 x ID ISCM01-A/B M81191-5E-ID.doc

More information

This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively.

This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively. This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively. Parallel - The Parallel port provides a control interface with video devices utilizing

More information

Thorsten Reibel, Training & Qualification Global Application and Solution Team

Thorsten Reibel, Training & Qualification Global Application and Solution Team JUNE 2017 Gateways DG/S x.64.1.1 Part 2 BU EPBP GPG Building Automation Thorsten Reibel, Training & Qualification Global Application and Solution Team Agenda New Generation DALI-Gateways DG/S x.64.1.1

More information

ADC Bit µp Compatible A/D Converter

ADC Bit µp Compatible A/D Converter ADC1001 10-Bit µp Compatible A/D Converter General Description The ADC1001 is a CMOS, 10-bit successive approximation A/D converter. The 20-pin ADC1001 is pin compatible with the ADC0801 8-bit A/D family.

More information

Voltage regulator TAPCON 240. Quick reference guide 230/05

Voltage regulator TAPCON 240. Quick reference guide 230/05 Voltage regulator TAPCON 240 Quick reference guide 230/05 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and communication of its contents are

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater For additional information contact matedev@outbackpower.com Page 1 of 20 Revision History Revision 2.0:

More information

RECOMMENDATION ITU-R BT *

RECOMMENDATION ITU-R BT * Rec. ITU-R BT.656-4 1 RECOMMENDATION ITU-R BT.656-4 * Interfaces for digital component video signals in 525-line and 625-line television systems operating at the 4:2:2 level of Recommendation ITU-R BT.601

More information

>pdrive< Operating instructions Modbus. Modbus

>pdrive< Operating instructions Modbus. Modbus >pdrive< Operating instructions Modbus >pdrive< >pdrive< >pdrive< >pdrive< >pdrive< MX eco 4V MX pro 4V MX pro 6V MX multi-eco MX multi-pro Modbus General remarks The following symbols should assist you

More information

LIN Bus Shunt. Slave Node Position Detection. Revision 1.0. LIN Consortium, LIN is a registered Trademark. All rights reserved.

LIN Bus Shunt. Slave Node Position Detection. Revision 1.0. LIN Consortium, LIN is a registered Trademark. All rights reserved. December 10, 2008; Page 1 LIN Bus Shunt LIN Consortium, 2008. LIN is a registered Trademark. All rights reserved. December 10, 2008; Page 2 DISCLAIMER This specification as released by the LIN Consortium

More information

GSM/GPRS/GPS Tracker GV100. User Manual TRACGV100UM001. Revision: Quectel Wireless Solutions

GSM/GPRS/GPS Tracker GV100. User Manual TRACGV100UM001. Revision: Quectel Wireless Solutions GSM/GPRS/GPS Tracker GV100 User Manual TRACGV100UM001 Revision: 1.00 Quectel Wireless Solutions www.quectel.com Info@quectel.com Document Title GV100 User manual Version 1.00 Date 2009-10-15 Status Document

More information

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Electronic Load Electronic AC Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available 4226

More information

M-BUS Communication Protocol. -for M-BUS modules and counters with integrated M-BUS interface-

M-BUS Communication Protocol. -for M-BUS modules and counters with integrated M-BUS interface- M-BUS Communication Protocol -for M-BUS modules and counters with integrated M-BUS interface- USER MANUAL v009 - June edition 2017 Limitation of Liability The Manufacturer reserves the right to modify

More information

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

Select datum Page backward in parameter list

Select datum Page backward in parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

96M0374. Instruction Manual. Analog Sensor Controller. RD Series Instruction Manual Analog Sensor Controller RD Series 96M0374 Safety precautions This manual describes how to install the RD Series as well as its operating procedures and precautions. Please read this

More information

MTS2500 Synthesizer Pinout and Functions

MTS2500 Synthesizer Pinout and Functions MTS2500 Synthesizer Pinout and Functions This document describes the operating features, software interface information and pin-out of the high performance MTS2500 series of frequency synthesizers, from

More information

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01 INTERBUS Inline Terminal With One Analog Voltage Output Data Sheet 5736CC01 05/2001 # %! $ ) This data sheet is intended to be used in conjunction with the Configuring and Installing the INTERBUS Inline

More information

Position Indicator model MFC-300/IP. Technical Manual. Licht

Position Indicator model MFC-300/IP. Technical Manual. Licht Position Indicator model MFC-300/IP Technical Manual Licht Contents 1 Introduction 2 2 Front panel indication 3 3 Error indication 4 4 Manual commands 5 5 Configuration 6 5.1 Parameter reset 6 6 Programmable

More information

Communication With NC-Module

Communication With NC-Module UFM UDM Communication With NC-Module Telegram Description PLC/NC-Module Profibus HB Profibus Protocol UD 73 English V3.doc content: 1 General... 1 2 Interfaces... 2 3 Connections... 3 3.1 Supply voltage,

More information

I2C Demonstration Board I 2 C-bus Protocol

I2C Demonstration Board I 2 C-bus Protocol I2C 2005-1 Demonstration Board I 2 C-bus Protocol Oct, 2006 I 2 C Introduction I ² C-bus = Inter-Integrated Circuit bus Bus developed by Philips in the early 80s Simple bi-directional 2-wire bus: serial

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed

More information

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC. DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC. 1-7-3, HIGASHI BENZAI, ASAKA CITY SAITAMA 351-22 JAPAN TEL : 81-48-468-694 FAX : 81-48-468-621 http://www.dst.co.jp/en 1 DPL-2.5GF

More information

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

Variable-Gain High Speed Current Amplifier

Variable-Gain High Speed Current Amplifier Features Transimpedance (Gain) Switchable from 1 x 10 2 to 1 x 10 8 V/A Bandwidth from DC up to 200 MHz Upper Cut-Off Frequency Switchable to 1 MHz, 10 MHz or Full Bandwidth Switchable AC/DC Coupling Adjustable

More information

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Controller for the Implementation of a Central or Decentralized Electrohydraulic System EFX 1624m Electronic Controller Programmed with Eaton CONTROL F(x) Software to IEC 61131-3 Standard 2nd CAN interface for gateway function according to SAE J1939 Supply voltage 10...32V DC Technical Data

More information

13. OP-03 RS-232C SERIAL INTERFACE

13. OP-03 RS-232C SERIAL INTERFACE This document hosted by: www.oldwillknottscales.com 13. OP-03 RS-232C SERIAL INTERFACE This interface allows the HC-i series to be connected with a multifunction printer or a personal computer. The OP-03

More information

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B.   Innovation through Guidance. Autonomous Vehicles Device Description HG G-84300-B Autonomous Vehicles Gyroscope HG G-84300-B Gyro for AGV English, Revision 06 Date: 24.05.2017 Dev. by: MG/WM/Bo Author(s): RAD Innovation through Guidance www.goetting-agv.com

More information

LCC-10 Product manual

LCC-10 Product manual LCC-10 Product manual Rev 1.0 Jan 2011 LCC-10 Product manual Copyright and trademarks Copyright 2010 INGENIA-CAT, S.L. / SMAC Corporation Scope This document applies to i116 motion controller in its hardware

More information

User manual. Inclinometer with Analog-RS232-Interface IK360

User manual. Inclinometer with Analog-RS232-Interface IK360 User manual Inclinometer with Analog-RS232-Interface IK360 Table of content 1 GENERAL SAFETY ADVICE... 3 2 INTRODUCTION... 4 2.1 IK360... 4 2.2 ANALOG INTERFACE... 4 2.3 IK360 ANALOG... 4 3 INSTALLATION...

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Dimensioned drawing en 02-2012/11 50118552 50 100mm 18-30 V DC We reserve the right to make changes DS_ODSL9L100_en_50118552.fm High resolution 0.01mm Reflection-independent distance information Highly

More information

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many RXQ2 - XXX GFSK MULTICHANNEL RADIO TRANSCEIVER Intelligent modem Transceiver Data Rates to 100 kbps Selectable Narrowband Channels Crystal controlled design Supply Voltage 3.3V Serial Data Interface with

More information

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual Carbon Dioxide (Tiny CO2) Gas Sensor Rev. 1.2 TG400 User Manual The TG400 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

Know your energy. Modbus Register Map EB etactica Power Bar

Know your energy. Modbus Register Map EB etactica Power Bar Know your energy Modbus Register Map EB etactica Power Bar Revision history Version Action Author Date 1.0 Initial document KP 25.08.2013 1.1 Document review, description and register update GP 26.08.2013

More information

Ultrasonic Multiplexer OPMUX v12.0

Ultrasonic Multiplexer OPMUX v12.0 Przedsiębiorstwo Badawczo-Produkcyjne OPTEL Sp. z o.o. ul. Morelowskiego 30 PL-52-429 Wrocław tel.: +48 (071) 329 68 54 fax.: +48 (071) 329 68 52 e-mail: optel@optel.pl www.optel.eu Ultrasonic Multiplexer

More information

DALI slave, one to four channels PWM and I2C output

DALI slave, one to four channels PWM and I2C output DALI slave, one to four channels PWM and I2C output 1. Features DALI to PWM and I2C controller Pin selectable 1 to 4 channels Access to raw arc power values via I2C Access to mapped brightness values via

More information

Unit D. Serial Interfaces. Serial vs. Parallel. Serial Interfaces. Serial Communications

Unit D. Serial Interfaces. Serial vs. Parallel. Serial Interfaces. Serial Communications D.1 Serial Interfaces D.2 Unit D Embedded systems often use a serial interface to communicate with other devices. Serial implies that it sends or receives one bit at a time. Serial Communications Serial

More information

MODEL: DLS. Telemetering System

MODEL: DLS. Telemetering System POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power

More information

U1601 ENERGY CONTROL SYSTEM

U1601 ENERGY CONTROL SYSTEM 3-348-844-03 4/8.05 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring

More information

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw isma-b-w0202 isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw www.gc5.com 1. Introduction... 4 2. Safety rules... 4 3. Technical specifications... 5 4. Dimension... 6 5. LED Indication...

More information

BVW Series DVW Series DNW Series HDW Series

BVW Series DVW Series DNW Series HDW Series VIDEO CASSETTE RECORDER/PLAYER BVW Series DVW Series DNW Series HDW Series PROTOCOL OF REMOTE (9-pin) CONNECTOR 2nd Edition (Revised 5) Table of Contents. Interface System Overview... 2. Command Block

More information

Modbus Communications System for Micrologic A, P, and H Trip Units Class 0613

Modbus Communications System for Micrologic A, P, and H Trip Units Class 0613 Modbus Communications System for Micrologic A, P, and H Trip Units Class 0613 Data Bulletin 0613IB1201 06/2012 Retain for future use. 0613IB1201 Modbus Communications System for Micrologic A, P, and H

More information

Kongsberg Mesotech Ltd.

Kongsberg Mesotech Ltd. Kongsberg Mesotech Ltd. Doc. No. : 974-00007904 Title : Digital Telemetry Notes elease : Version 1.4 Date : 2010-04-30 1. PUPOSE This document briefly describes the digital telemetry standards, formats

More information

Instruction manual. art Installation manual

Instruction manual. art Installation manual Instruction manual art. 01521 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 4 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL FEATURES AND

More information

CANopen Programmer s Manual Part Number Version 1.0 October All rights reserved

CANopen Programmer s Manual Part Number Version 1.0 October All rights reserved Part Number 95-00271-000 Version 1.0 October 2002 2002 All rights reserved Table Of Contents TABLE OF CONTENTS About This Manual... iii Overview and Scope... iii Related Documentation... iii Document Validity

More information

ECOS SRIF Operating Instructions

ECOS SRIF Operating Instructions ECOS SRIF 2002 Operating Instructions Edition 10/2003 Safety instructions This document contains instructions you are strongly advised to observe in order to guarantee your personal safety and to avoid

More information

Digital Interface Option "OPC-E1-DIO"

Digital Interface Option OPC-E1-DIO Instruction Manual Digital Interface Option "OPC-E1-DIO" Thank you for purchasing our digital interface option. Read through this instruction manual and be familiar with the digital interface option before

More information

SWT 3000 Teleprotection technical data siemens.com

SWT 3000 Teleprotection technical data siemens.com Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable

More information