1 Class 300 Equipment CBS 305, 320 Current Boost Systems CBS 320 Current Transformer CBS 305 The CBS 305 and CBS 320 Current Boost Systems are electronic devices designed to provide the Basler APR series of static voltage regulators with power to sustain exciter current when severe overloading of brushless generators occurs such as during motor starting or during short circuit conditions. Power for the current boost systems is derived from a power CT installed in two phases of the generator output. FEATURES Instantaneous response to short circuits. DESCRIPTION Page 2 SPECIFICATIONS Pages 2 through 4 Up to 7.2 A field boost power. Actuated when the generator voltage drops too low to maintain field current. Compatible with Frequency Compensation. Boost is inhibited by low frequency. For 50 or 60 Hertz brushless generators. Each model covers a wide range of generator application. ORDERING Page 4 OUTLINE DRAWINGS Pages 7 and 8 Totally encapsulated to eliminate the effects of vibration, dust, or moisture. CSA approved. P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX SRR

2 The Current Boost System consists of a current boost module auto-and a current transformer (CT). The system provides supplemental excitation source with the regulator which allows the field to receive full forcing during generator overloading and short circuits. The Current Boost System allows three wire and four wire generators to provide current during sustained single phase and multiple phase line-to line faults. The CBS also permits four wire generators to support phase A and C line to neutral faults. Phase B line-to-neutral faults will also have fault sustaining capabilities since the regulator and CBS input power is taken from the other unshorted phases. The Current Boost Module uses the CB+ and CBoutputs of the APR regulator as a turn-on signal. Boost power to the module is supplied from a CT installed in phase A and C of the generator output. During short circuits, the CT is the source of all excitation current for the generator - see figure 2. Because the APR regulator sensing is used to turn the boost on and off, the Current Boost System operating OUTPUT POWER DC Output Power Field Resistance For Use DC Volts DC Amps Ohms Ohms Model With Range (min) (max) CBS305 APR CBS320 APR MAXIMUM INPUT CURRENT FROM CT: CBS 305 and CBS 320: 7A continuous CBS 305: 33A for 30 seconds CBS 320: 45A for 30 seconds POWER DISSIPATION: CBS 305 and CBS 320: 24 watts in non-boost mode CT-BE : 25 watts maximum CT-BE : 35 watts maximum CT-BE : 70 watts maximum TRANSIENT RESPONSE: Less than 2 cycles from regulator s boost signal until boost output reaches 90Vdc. DESCRIPTION SPECIFICATIONS level is automatically adjusted to the nominal generator voltage. The Current Boost System also follows the regulator s underfrequency curve to allow the prime mover to pick up large loads in one step. To verify that the available CTs will accommodate the generator s output cable, refer to HOW TO ORDER - Current Transformer. Three CTs are available: a.be for use with the CBS 305 only and on generators with rated line currents up to 800A. b.be for use with the CBS 320 on generators with rated line currents up to 800A. c.be for use with either the CBS 305 or CBS 320 on generators with rated line currents up to 2400A. The CBS 305 and CBS 320 are totally encapsulated to eliminate all effects of moisture, dust, vibration, and shock as hazards to operation. CT SECONDARY TURNS: BE : Terminals 1 and turns BE : Terminals 1 and turns BE : Terminals 1 and turns Terminals 1 and turns CONTROL SIGNAL FROM APR REGULATOR: 10mA, 1.5Vdc SHOCK: Withstands 15 Gs in each of three mutually perpendicular planes. VIBRATION: Withstands the following vibration spectrum: Frequency Acceleration 5-26 Hz 1.2 G Hz in. displacement Hz 5 G CT SECONDARY INSULATION RATING: 2500 Vac HI-Pot STORAGE TEMPERATURE: -65 C (-85 F) to +85 C (+185 F) OPERATING TEMPERATURE RANGE: -40 C (-40 F) to +60 C (+140 F) 2 HUMIDITY: Totally protected from humidity and condensation by encapsulation.

3 SPECIFICATIONS, continued WEIGHT: Current Boost Module: CBS Ibs. (1.2kg) net 3.6 Ibs. (1.6kg) shipping See Figure 3 for dimensions. CBS Ibs.(2.9kg) net 8 Ibs, (3.6kg) shipping See Figure 4 for dimensions. Current Transformers: BE See Figure 5 for dimensions Ibs. (7.lkg) net 17 Ibs. (8kg) shipping BE Ibs. (13kg) net 31 Ibs. (14kg) shipping See Figure 6 for dimensions. BE Ibs. (2Okg) net 55 Ibs. (25kg) shipping See Figure 7 for dimensions. Figure 2 - Typical Interconnection Diagram 3

4 SPECIFICATIONS, continued SAMPLE SPECIFICATION: A current boost system shall be provided with the Basler APR 63-5 voltage regulator to sustain exciter field current during severe generator output overloads or short circuit. The operation of the current boost system shall be controlled by the voltage regulator. by a CT installed in two phases of the generator output. The current boost system shall be a Basler Electric Company Mode CBS 305 current boost system, with a current transformer selected based on Basler recommendation and generator performance data. Power for the current boost system shall be provided HOW TO ORDER - Current Boost System: When the CBS is Order to be used with APR63-5 CBS 305 APR125-5 CBS 320 HOW TO ORDER - Current Transformer (CT): Follow the step-by-step procedure below to select the proper turns-ratio for your application. Based on the resulting turns-ratio, wire or bus size, and rated generator output current, determine the part number of the CT having the proper rating and window size. Step 1. Calculate the exciter field current during generator short circuit: I Field = E/R f Where: I Field = Exciter field Current at short Circuit. R f = Exciter field resistance from generator data. E = CBS field forcing voltage (90 Vdc for CBS 305,180 Vdc for CBS 320) Step 2. From the generator manufacturer s short circuit saturation data (plot of exciter field current versus line amps with generator output short circuited), determine the generator three phase line current during a short circuit that would result from the exciter field current calculated in step 1. If for your generator system: This results in excessive generator linecurrent. Then proceed to: Step 3A This results in acceptable generator linecurrent. Step 38 Step 3A. a. Determine the acceptable generator three phase line current at short circuit (typically 300% of nominal). Refer to Table 1 and locate the range that covers this value in column 1. b. Using the generator manufacturer s short circuit data (plot of exciter field current versus line amps with the generator output short circuited), determine the exciter short circuit field current required to generate the acceptable generator line current (1 2 ). Refer to Table 1 and locate the current value equal to this value in column 3. If the desired field current is in between the column 3 values, go to the next higher value. c. Check that the rated generator full load line current doesn t exceed the maximum continuous line current in column 2. If the generator full load line current does exceed the maximum continuous line current rating, consult with the factory. d. To obtain reduced field current, place a current limiting resistor in series with the exciter field. Calculate the value of this resistor as follows: R S = E/I 2 - R f Where: R S = Value of series field resistance to be added (in ohms). This resistance must not be so great as to restrict normal forcing. E = CBS field forcing voltage (90 Vdc for CBS 305, and 180 Vdc for CBS 320). I 2 = Field current required to produce acceptable generator line current at short circuit from b. above. R f = Exciter field resistance from generator data. e. Proceed to step 4. Step 3B. 4

5 HOW TO ORDER, continued a. In Table 1. column 1, locate the range of the generator three phase short circuit line current that covers the value determined in step 2. b. Check that rated generator line current does not exceed the maximum continuous line current in column 2. c. In Table 1, column 3, locate the exciter field current that is closest to the value determined in step 1. If the value is between the values in column 3, go to the next higher value. d. Proceed to step 4. a. Find the turns-ratio at the point of intersection of the values found in step 3. b. The first numeral of the turns-ratio indicates the number of turns of each of two (2) generator lines that pass through the CT window. The second number indicates secondary turns provided by the CT terminals. Step 5. Verify that the CT window size is sufficient for the generator conductors by comparing the conductor cross-section (including insulation) with the window area shown in figure 5, 6, or 7. Step 4. Column 1 Column 2 Column 3 3 Phase Line Maximum Exciter Field Current at Rated CBS Continuous Output Voltage (90 Vdc for CBS 305 or Short Circuit Line Current 180 Vdc for CBS 320) 1.8Adc 3.6Adc 7.2Adc :209 16:209 32: :209 8:209 16: :209 4:209 8: :209 2:209 4: :209 1:209 2:209 BE for CBS 305 or BE for CBS :209 1:209 1: :616 1:616 1:308 BE for CBS :616 1:616 1:616 and CBS 320 Table 1 - Turns-Ratio Selection 5

6 EXAMPLE of the HOW TO ORDER - (CT) procedure on page 4. Sample Generator Data: 100KW, 125kVA, 60Hz, 3-phase, 480V, 150A at full rated load, 15 ohm field. IF = 300% short circuit (450A line) IF = % short circuit (525A line) (Step 1) Determine the field current that will be provided by a Basler CBS 305 during short circuit: Where: I F = E 900 Vdc = = 6.0A R 15 ohms I F = Field Current E = APR63-5/CBS305 Maximum dc output voltage. R = Exciter field resistance. (Step 2) From generator manufacturer s data, you determine that the exciter field current of 6.0A from the CBS 305 would result in a short circuit line current of 525A- for your generator system you consider this to be: EXCESSIVE (Step 3A) You determine that 450A would constitute an acceptable generator line current at short circuit. From the generator manufacturer s data, you determine that an exciter field current of 5.14A is required for the generator system to deliver an acceptable 450A at short circuit. In Table 1, column 1, the value of 450A is between the values of 275 to 550A. Draw a horizontal line from this point across the chart. In Table 1, column 3, the value of 7.2A is the closest higher value to the required value of 5.14A (from step 3A). Draw a vertical line from this point down the chart. In Table 1, column 2, the maximum continuous line current of 200A is greater than the full load line current of 15OA. therefore, the limits of the CT are not exceeded. Determine the necessary resistance to be added to the exciter field to achieve the 5.14A exciter field current: E R S = - R f = 90 Vdc - 15 ohms = ohms I = 2.5 ohms Note - The series resistance must not be so great as to restrict normal forcing. (Step 4) From Table 1, the intersection of the two lines (from step 3A) is the turnsratio, 4: turns on the primary: 209 turns on the secondary. (Step 5) The first numeral of the turns-ratio (4), the number of conductors per phase (1) and the number of phase (2) multiplied together results in: 8 conductors (through the CT window). From the generator manufacturer s data, is the conductor diameter; therefore, for 8 conductors the CT window must be at least in X 4.30 inches. Basler CT P/N BE is 0.9 in. X in. and meets the requirement. ACCEPTABLE (Step 38) In table 1, column 1, the value of 525A (from step 2) is between the values of A. Draw a horizontal line from this point across the chart. In Table 1, column 2, the maximum continuous line current of 200A is greater than the full load line current of 150A, therefore, the limits of the CT are not exceeded. n Table 1, column 3, the value of 7.2A is the next higher value after the required value of 6.OA (from step 1). Draw a vertical line from this point down the chart. (Step 4) From Table 1, the intersection of the two lines (from step 3A) is the turns-ratio, 4:209, 4 turns on the primary: 209 turns on the secondary (Step 5) The first numeral of the turns-ratio (4) the number of conductors per phase (1) and the number of phases (2). multiplied together results in: 8 conductors (through the CT window). From the generator manufacturer s data, is the conductor diameter; therefore, for 8 conductors, the CT window must be at least in. x 4.30 in. Basler CT P/N BE is 0.9 in. x in. and meets the requirement. 6

7 OUTLINE DRAWINGS Figure 3 - Outline Drawing, Current Boost Module (CBS 305) Figure 4 - Outline Drawing, Current Boost Module (CBS 320) 7

8 OUTLINE DRAWINGS Figure 5 - Outline Drawing, Current Transformer P/N BE Figure 6 - Outline Drawing, Current Transformer P/N BE Figure 7- Outline Drawing, Current Transformer P/N BE Note: All dimensions in inches (millimeters) All drawings and data subject to change without notice. ROUTE 143, BOX 269, HIGHLAND, ILLINOIS U.S.A P.A.E. Les Pins, Wasselonne Cedex FRANCE PHONE FAX PHONE ( ) FAX ( ) info@basler.com

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM APPLICATION: Many brushless exciter-equipped generators are required to sustain the substantial current overloads associated with starting large motors. Typically,

More information

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES BE1-81O/U DIGITAL FREQUENCY RELAY The BE1-81O/U Digital Frequency Relay senses an ac voltage from a power system or generator to provide protection in the event that the frequency exceeds predetermined

More information

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY The BE1-32R Directional Overpower Relay and the BE1-32 O/U Directional Over/Underpower Relay are solid-state devices which provide versatility and control in

More information

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY The BE1-87G is a single or three-phase solid-state variable percentage differential relay designed to provide selective, high-speed, differential protection

More information

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency www.basler.com + 68.654.234 (USA) info@basler.com Model Description AVC25-0 Voltage Regulator INTRODUCTION The AVC63-2 and AVC25-0 regulate the level of excitation supplied to the field of a conventional,

More information

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2 BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY The BE1-67N Ground Directional Overcurrent Relay provides ground fault protection for transmission and distribution lines by sensing the direction and magnitude

More information

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL McPherson Voltage Regulators 4501 NW 27 Ave Miami FL 33142 305-634-1511 To avoid of possible personal injury or equipment damage read and understand this manual before installation. (A.V.R) 208 / 380 /

More information

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations

More information

www. ElectricalPartManuals. com .Basler Electric 15 Amp DECS DIGITAL EXCITATION CONTROL SYSTEM DESCRIPTION & SPECIFICATIONS pages 2 & 3

www. ElectricalPartManuals. com .Basler Electric 15 Amp DECS DIGITAL EXCITATION CONTROL SYSTEM DESCRIPTION & SPECIFICATIONS pages 2 & 3 Basler's igital Excitation Control System (ECS) provides customizable performance and high reliability. The microprocessor based design allows greater flexibility in setting all functions and adjustments

More information

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges. APPLICATION: Basler Electric offers a New Line of digitally controlled brush (static) or brushless excitation systems designed for use with existing Hydro, Gas as well as Diesel driven generators requiring

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6

More information

HPS Universal BUCK-BOOST TRANSFORMERS

HPS Universal BUCK-BOOST TRANSFORMERS BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

GENERATOR DATA JANUARY 30, 2015

GENERATOR DATA JANUARY 30, 2015 GENERATOR DATA JANUARY 30, 2015 For Help Desk Phone Numbers Click here Generator Specification Frame: 1822 Type: SR5 No. of Bearings: 2 Winding Type: FORM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing:

More information

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C. SPECIFICATION SWITCHING POWER SUPPLY BPS-250S 6-OUTPUT SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C. Tel: 886-2-8647-1188 Fax: 886-2-8647-3322

More information

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC. SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC. 2F, NO.196-10, SEC.3, DA-TONG RD., XIZHI DIST., NEW TAIPEI CITY, TAIWAN

More information

BUCK-BOOST TRANSFORMERS

BUCK-BOOST TRANSFORMERS Where Are Buck-Boost Transformers Used? A typical buck-boost application is 120 volts in, 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage transformer

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Spec Information Generator Specification Frame: LC6134K Type: LC No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 18.0 Connection: - STAR Housing: 0 Phases: 3 No. of Leads: 6 Poles:

More information

www. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL

www. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL ...... The BE181 0/U Digital Frequency Relay senses an ac voltage: from a power system or generator to provide protection in the event that the frequency exceeds predetermined limits. Reliable solidstate

More information

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input. The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. The MPU150-4530G and MPU150-4350G provide high current +3.3 V and

More information

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2 SNP-Z077 Specification Page 1 of 7 70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL...2 2. CIRCUIT TOPOLOGY...2 3. AC INPUT...2 3.1. INPUT VOLTAGE...2 3.2. INPUT

More information

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase... SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make

More information

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-370RDX 6-OUTPUT 370W+370W 1.0 General 1.1 Parameter Specifications 2.0 Input Characteristics 2.1 Input Voltage 2.2 Input Waveform 2.3 Input Frequency

More information

56 mm sq. (2.20 inch sq.)

56 mm sq. (2.20 inch sq.) 56 mm sq. (. inch sq.) 1.8 /step RoHS Unipolar winding, Lead wire type Bipolar winding, Lead wire type p. 7 Customizing Hollow Shaft modification Decelerator Encoder Varies depending on the model number

More information

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT RK-23/048RD100-7200 SPECIFICATION SCOPE This functional specification defines the performance characteristics of the switching mode regulated power supply, and also defines world wide safety requirements

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

How to Choose Power Supplies

How to Choose Power Supplies How to Choose Power Supplies Overview C5 D-Style Software Which is Better, Linear or Switcher Supplies? Because servo motors are inductive, they may run highly dynamic motion profiles. As a result, their

More information

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

IC800SSD Hardware Manual Pub 348R5. for models. A publication of IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A

More information

High Frequency SineWave Guardian TM Filter

High Frequency SineWave Guardian TM Filter High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference

More information

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD. The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet

More information

TRANSFORMER OPERATION

TRANSFORMER OPERATION Chapter 3 TRANSFORMER OPERATION 1 A transformer is a static device (no moving parts) used to transfer energy from one AC circuit to another. This transfer of energy may involve an increase or decrease

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

Product Specification

Product Specification MODEL NO. WP507F12 This power supply is a small footprint, AC input power supply. This power supply is capable of supplying 400 watts of output power into 5 DC output voltages. 1.0 INPUT REQUIREMENTS 1.1

More information

CENTIGRID ESTABLISHED RELIABILITY RELAYS

CENTIGRID ESTABLISHED RELIABILITY RELAYS SERIES DESIGNATION CENTIGRID ESTABLISHED RELIABILITY RELAYS SENSITIVE DPDT 134 DPDT basic relay 134D 134DD RELAY TYPE DPDT relay with internal diode for coil transient suppression DPDT relay with internal

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL SINGLE PHASE INSTRUCTION MANUAL DIAGRAM D This manual applies to all single-phase buck & boost transformers sold by Larson Electronics. Please refer to the connection diagram on pages 4-6 for properly

More information

Steps for Selecting the Proper Transformer

Steps for Selecting the Proper Transformer SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

60 mm sq. (2.36 inch sq.)

60 mm sq. (2.36 inch sq.) 6 mm sq. (.36 inch sq.) 1.8 /step RoHS Unipolar winding, Connector type Unipolar winding, Dimensions for attaching NEMA3 are interchangeable (47.14 mm-pitch) Bipolar winding, Connector type p. 76 Bipolar

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

U, W, and Y -- MULTIPLE LEG STARBARS, SILICON CARBIDE HEATING ELEMENTS

U, W, and Y -- MULTIPLE LEG STARBARS, SILICON CARBIDE HEATING ELEMENTS U, W, and Y -- MULTIPLE LEG STARBARS, SILICON CARBIDE HEATING ELEMENTS GENERAL DESCRIPTION Made of high density recrystallized silicon carbide, these multiple leg Starbars use the same hot zone and cold

More information

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC. SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC. 2F, NO.196-10, SEC.3, DA-TONG RD., XIZHI DIST., NEW TAIPEI CITY, TAIWAN R.O.C. Tel: 886-2-8647-1188

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression ESTABLISHED RELIABILITY SERIES DESIGNATION MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT 420/422 DPDT basic relay 420D/422D 420DD/422DD RELAY TYPE DPDT relay with internal diode for coil transient

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

4X150A/7034 Radial Beam Power Tetrode

4X150A/7034 Radial Beam Power Tetrode 4X15A/734 Radial Beam Power Tetrode T The Svetlana 4X15A/734 is a compact radial beam tetrode. The 4X15A is intended for Class AB SSB linear RF amplifier service. It is intended for stationary and mobile

More information

Linear Power Supplies Data Sheet

Linear Power Supplies Data Sheet Features Description Power-One produces the industry s broadest selection of Linear power supplies with output voltages from 5 volts through 250 volts. Rugged technology and proven design merge to create

More information

Current Loop Interface Module M 2025D

Current Loop Interface Module M 2025D CONTROLS Current Loop Interface Module M 2025D Current-to-Voltage Analog Converter used with the M 2001 Series Digital Tapchanger Control and M-2948 Tap Position Sensors to provide positive tap position

More information

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3 HPU1K5 Series Low Profile 1.7 (43.2 mm), Industrial Supply Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals Output Power up to 1500 W Load dependant variable speed fans for audible

More information

HLC-1000 High-limit Humidity Control

HLC-1000 High-limit Humidity Control FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification

More information

D I G I T A L V O L T A G E R E G U L A T O R

D I G I T A L V O L T A G E R E G U L A T O R The Cat Digital Voltage Regulator is a microprocessor based control designed to provide precise voltage control, robust transient response, and generator protection with industry leading features and versatility.

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS 815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS USER GUIDE September 2004 Important Notice This document is subject to the following conditions and restrictions: This document contains proprietary information

More information

DATASHEET VXR S SERIES

DATASHEET VXR S SERIES VXR250-2800S SERIES HIGH RELIABILITY COTS DC-DC CONVERTERS DATASHEET Models Available Input: 11 V to 60 V continuous, 9 V to 80 V transient 250 W, single output of 3.3 V, 5 V, 12 V, 15 V, 28 V -55 C to

More information

Design Characteristics. FlexDrive II. Series

Design Characteristics. FlexDrive II. Series AC AC DC DC FlexDrive II Series Design Characteristics Brushless AC Servo Baldor s FlexDrive II series are designed to provide reliable and durable operation. Options are available to operate either resolver

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 4.doc Document Number 69493 Page 1 of 17 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE SENSE...

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

TV31 Voltage/ Current Transformer

TV31 Voltage/ Current Transformer TV31 PCB Mounted Voltage/Current Transformers The Yuanxing TV31 voltage/ current transformer is designed for applications where the primary AC signal must be transformed accurately into a lower secondary

More information

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX The BE1-47N Voltage Phase Sequence Relay provides protection for rotating equipment from the damaging effects of excessive negative sequence voltage resulting from phase failure, phase unbalance and reversed

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

VXR S SERIES 1.0 DESCRIPTION 1.1 FEATURES 1.2 COMPLIANCE 1.3 PACKAGING 1.4 SIMILAR PRODUCTS AND ACCESSORIES

VXR S SERIES 1.0 DESCRIPTION 1.1 FEATURES 1.2 COMPLIANCE 1.3 PACKAGING 1.4 SIMILAR PRODUCTS AND ACCESSORIES VXR15-2800S SERIES HIGH RELIABILITY COTS DC-DC CONVERTERS Models Available Input: 9 V to 60 V continuous, 6 V to 100 V transient 15 W, single output of 3.3 V, 5 V, 12 V, 15 V -55 C to 105 C Operation 1.0

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark SFX Form Factor SST-SX650-G SST-SX500-G The standard SFX power supply benchmark Support standard SFX form factor Silent running 92mm fan with 18 dba minimum All Japanese capacitors High efficiency with

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 6a.doc Document Number 69493 Page 1 of 20 1. INPUT... 4 AC INPUT LINE REQUIREMENTS... 4 2. DC OUTPUT... 4 OUTPUT VOLTAGES all models

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation... General... 28 Remote Sense... 29 Remote On / Off... 30 Output Trim... 30 Series Operation... 32 Parallel Operation... 33 Synchronization... 33 Power Good Signal... 34 Electro Magnetic Filter (EMI)... 34

More information

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms part of

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525 ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525 1.0 SCOPE 2.0 INPUT REQUIREMENTS 2.1 VOLTAGE 2.2 FREQUENCY 2.3 STEAD-STATE CURRENT 2.4 INRUSH CURRENT 3.0 OUTPUT REQUIREMENTS 3.1 AC

More information

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W Data Sheet SE014S110 Power Module; dc-dc Converter: Features The SE014S110 Power Module uses advanced, surface-mount technology and delivers high-quality, compact, dc-dc conversion at an economical price.

More information

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C GE Power Management Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C 7$%/(2)&217(176 1. DESCRIPTION...2 2. APPLICATION...6 3. CHARACTERISTICS...7

More information

PROXIMITY SENSOR TERMINOLOGY

PROXIMITY SENSOR TERMINOLOGY Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.

More information

Protective Relays Digitrip 3000

Protective Relays Digitrip 3000 New Information Technical Data Effective: May 1999 Page 1 Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer

More information

INSTRUCTION MANUAL FOR TIME OVERCURRENT RELAY BE1-51

INSTRUCTION MANUAL FOR TIME OVERCURRENT RELAY BE1-51 INSTRUCTION MANUAL FOR TIME OVERCURRENT RELAY BE1-51 Publication: 9137200997 Revision: E 07/10 INTRODUCTION This instruction manual provides information about the operation and installation of the BE1-51

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

50W TO220 High Power Resistors

50W TO220 High Power Resistors 50W TO220 High Power Resistors MHP 50 Non-inductive, thin film technology. Thermally enhanced Industry standard TO220 package. RoHS compliant. Low thermal resistance, 2.3 C/W resistor hot spot to metal

More information

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0 TC-2U70PD8 TC-2U70PD8 Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION Revision: 2.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-303-8885 FAX: 626-301-0588

More information

Switching Power Supply Type SPP1 60W Enclosed type

Switching Power Supply Type SPP1 60W Enclosed type Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and

More information

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc Product Facts Designed to be the smallest, lightest weight, lowest cost sealed contactor in the industry with its current rating (500+A carry, 2000A interrupt at 320VDC) Built-in coil economizer only 1.7W

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety,

More information

WATT TRANSDUCER. Instruction Manual

WATT TRANSDUCER. Instruction Manual WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com SPECIFICATIONS Power Supply Input

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com

More information

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You. PART NUMBER SELECTION Models: 2: Without 50 Ω terminations 4: With 50 Ω terminations RF Connectors: 3: SMA up to 6 GHz 4: SMA up to 20 GHz F: SMA up to 26.5 GHz 8: SMA 2.9 up to 40 GHz (1) Radiall s TITANIUM

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

PERFORMANCE SPECIFICATION SHEET GENERATOR SYSTEM, ALTERNATING CURRENT INTEGRALLY EXCITED, BRUSHLESS (P-3 AIRCRAFT)

PERFORMANCE SPECIFICATION SHEET GENERATOR SYSTEM, ALTERNATING CURRENT INTEGRALLY EXCITED, BRUSHLESS (P-3 AIRCRAFT) INCH-POUND (AS) 22 March 2010 SUPERSEDING MS9032G(AS) 1 February 1980 PERFORMANCE SPECIFICATION SHEET GENERATOR SYSTEM, ALTERNATING CURRENT INTEGRALLY EXCITED, BRUSHLESS (P-3 AIRCRAFT) This specification

More information

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Rotek AS440 compatible VOLTAGE REGULATOR (AVR) Rotek AS440 compatible VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms

More information

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA MBC10641 Bipolar Microstep Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

SINGLE-PHASE VSV SWITCH

SINGLE-PHASE VSV SWITCH May 2006 Supercedes: March 2006 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...2 IV. Maintenance...4 V. VSV Power

More information

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DSR120 Series. xxx Series. 120 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 120 Watts xxx Series Ultra Slim Design - 32 mm 150% Peak Load for 3 seconds Ambient Operation from -25 C to +70 C Full Load at 60 C (24V/48V) High Efficiency - Up to 92% Volt-Free Contact for OK Selectable

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE NV175 Application notes 3.4.doc Document Number 69493 Page 1 of 16 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information