Agilent N8480 Series Thermocouple Power Sensors

Size: px
Start display at page:

Download "Agilent N8480 Series Thermocouple Power Sensors"

Transcription

1 Agilent N8480 Series Thermocouple Power Sensors Data Sheet The N8480 Series thermocouple power sensors are amongst Agilent s most accurate and reliable sensors. These will eventually replace the 8480 Series thermocouple range only better with EEPROM and extended frequency and power ranges. Features High accuracy with excellent linearity and noise specifications Wide dynamic range in a single sensor Autodownload of calibration factor and corrections from EEPROM Option CFT of the sensors are available for full codecompatibility with the 8480 Series Broad compatibility with existing power meters: PSeries (N9A/2A), EPMP Series (E446A/7A) and EPM Series (N93A/4A, E448B/9B) Accurate, repeatable measurements Here s how: Excellent linearity (% approx.) and noise specifications. The sensors low further enhances accuracy by minimizing mismatch uncertainty. As if this weren t enough, these sensors also come with dualrange power for greater sensitivity to fluctuating signals, in particular. With high accuracy and stability, the N8480 helps you test confidently, faster. Calibrationeasy testing During test, calibrating your sensor is an essential step, yet it shouldn t be taking too much of your time and effort. With the N8480 sensors, there s no need for cumbersome keyingin of calibration factor (CF), nor concern for manual input errors. That s because CF, linearity and temperature corrections are all stored in the sensors EEPROM autodownloaded on calibration. Efficient calibration procedure makes for efficient testing overall, with N8480. One sensor, WIDEST range Pick an N8480 sensor any one and you ll see how its wide dynamic range equip you for various applications: metrology labs, radar, mobile radio, TDMA, GSM, WCDMA and WiMAX TM, among others. With up to 55 dbm wide dynamic range, the N8480 Series offers you the widest thermocouple sensor power range in the industry. System integration can be a pain, but not with the N8480 The N8480 Series sensors are backward compatible with Agilent s leading range of power meters, including the PSeries, EPM P Series and EPM Series. All that s needed is a simple firmware upgrade that s downloadable from the website, for free. Codewise, 00% of SCPI codes used on the ESeries sensors are reusable on the N8480, and this includes most of the ones used on the 8480 Series. For code migration from the 8480 Series, CFT options of the N8480 sensors and these will behave much like the 8480 Series sensors they replace.

2 Specification definitions There are two types of product specifications: Warranted specifications Characteristic specifications Warranted specifications Warranted specifications are covered by the product warranty and apply over 0 C to 55 C, unless otherwise noted. Warranted specifications include Measurement Uncertainty calculated with 95% confidence. Characteristic specifications Characteristic specifications are not warranted. They describe product performance that is useful in the application of the power sensors by giving typical, but non warranted performance parameters. These characteristics are shown in italics or denoted as typical, nominal or approximate. Characteristic information is representative of the product. In many cases, it may also be supplemental to a warranted specification. Characteristic specifications are not verified on all power sensors. The types of characteristic specifications can be placed in two groups: The first group of characteristic types describes 'attributes' common to all products of a given model or option. Examples of characteristics that describe 'attributes' are product weight, and 50 W input Type N connector. In these examples product weight is an approximate value and a 50 W input is nominal. These two terms are most widely used when describing a product's 'attributes'. The second group of characteristic types describes 'statistically' the aggregate performance of the population of products. These characteristics describe the expected behavior of the population of products. They do not guarantee the performance of any individual product. No measurement uncertainty value is accounted for in the specification. These specifications are referred to as typical. Conditions The power meter and sensor meet its specifications when: Stored for a minimum of two hours at a stable temperature within the operating temperature range, and turned on for at least 30 minutes. The power meter and power sensor are within their recommended calibration periods. Used in accordance to the information provided in the power meter s user's guide. 2

3 Performance characteristics Specifications stated hereon refer to all N8480 Series power sensors, unless otherwise stated. The term standard refers to all N8480 Series sensors except Option CFT. Frequency and Dynamic Power Range Sensor Option Sensor Model Frequency Range Dynamic Power Range Standard N848A 0 MHz to 8 GHz 00 khz to 6 GHz 0 MHz to 26.5 GHz Option 33 0 MHz to 33 GHz 35 dbm to +20 dbm 50 MHz to 50 GHz 26.5 GHz to 40 GHz 33 GHz to 50 GHz N848B 0 MHz to 8 GHz 00 khz to 6 GHz 5 dbm to +44 dbm N848H 0 MHz to 8 GHz 00 khz to 6 GHz 5 dbm to +35 dbm Option CFT N848A 0 MHz to 8 GHz 00 khz to 6 GHz Option 33 0 MHz to 26.5 GHz 0 MHz to 33 GHz 30 dbm to +20 dbm 50 MHz to 50 GHz 26.5 GHz to 40 GHz 33 GHz to 50 GHz N848B 0 MHz to 8 GHz 00 khz to 6 GHz 0 dbm to +44 dbm N848H 0 MHz to 8 GHz 00 khz to 6 GHz 0 dbm to +35 dbm Damage Level Sensor Model Damage Level (Average Power) Damage Level(Peak Power) N848A +25 dbm 5 W/2 μs N848B +49 dbm 500 W/ μs N848H +40 dbm 00 W/ μs 3

4 Maximum Sensor Model Frequency Band (25 C ± 0 C) Maximum (0 C to 55 C) N848A 0 MHz to 30 MHz MHz to 50 MHZ.4 50 MHz to 2 GHz. 2 GHz to 2.4 GHz 2.4 GHz to 8 GHz khz to 300 khz khz to MHz.7.7 MHz to 2 GHz GHz to 6 GHz.07 0 MHz to 50 MHz MHz to 00 MHz. 00 MHz to 2 GHz GHz to 2.4 GHz GHz to 8 GHz GHz to 26.5 GHz GHz to 33 GHz MHz to 00 MHz.0 00 MHz to 2 GHZ GHz to 2.4 GHz GHz to 8 GHz 8 GHZ to 26.5 GHz GHz to 40 GHz GHz to 50 GHz GHz to 40 GHz GHz to 50 GHz N848B 0 MHz to 2 GHz GHz to 2.4 GHz GHz to 8 GHz khz to 2 GHz.0 2 GHz to 6 GHz.8 N848H 0 MHz to 8 GHz 8 GHz to 2.4 GHz GHz to 8 GHz khz to 6 GHz.3.4. Only applicable for Option 033 4

5 Typical, 0 MHz to 8 GHz (25 C±0 C) for N848A sensor Typical, 00 khz to 6 GHz (25 C±0 C) for sensor Typical, 0 MHz to 26.5 GHz (25 C±0 C) for sensor Typical, 50 MHz to 50 GHz (25 C ±0 C) for power sensor Typical, 33 GHz to 50 GHz (25 C ±0 C) for power sensor Typical, 26.5 GHz to 40 GHz (25 C ±0 C) for power sensor 5

6 Typical, 0 MHz to 8 GHz (25 C ±0 C) for N848B power sensor Typical, 00 khz to 6 GHz (25 C ±0 C) for power sensor Typical, 0 MHz to 8 GHz (25 C ±0 C) for N848H power sensor Typical, 00 khz to 6 GHz (25 C ±0 C) for power sensor 6

7 Power linearity* The N8480 Series power sensors' linearity is negligible except for the power range specified in the table below. Sensor Model Power Range Linearity (25 C ± 0 C) Linearity (0 C to 55 C) N848A dbm to <+5 dbm ±0.52% ±0.80% +5 dbm to +20 dbm ±0.80% ±.90% N848B +29 dbm to <+39 dbm ±0.52% ±0.80% +39 dbm to +44 dbm ±.66% ±2.75% N848H +7 dbm to <+30 dbm ±0.77% ±.05% +30 dbm to +35 dbm ±2.84% ±3.93% *after zero and calibration at ambient environment conditions Typical N848A/2A/5A and /AQ power linearity at 25 C, after zero and calibration with associated measurement uncertainty 0.5 Power level dbm to +20 dbm Measurement uncertainty ±0.35% % Error Input Power (dbm) Typical N848B/2B power linearity at 25 C, after zero and calibration with associated measurement uncertainty Power level 29 dbm to 40 dbm Measurement uncertainty ±0.35% % Error dbm to 44 dbm ±.2% Input Power (dbm) Typical N848H/2H power linearity at 25 C, after zero and calibration with associated measurement uncertainty Power level 7 dbm to 30 dbm Measurement uncertainty ±0.60% % Error dbm to 35 dbm ±2.39% Input Power (dbm) 7

8 Zero set, zero drift and measurement noise Sensor Model Sensor option Range Condition (RH) Zero set Zero drift 2 Measurement noise 3 N848A Upper 20% 70% +/63 nw <+/7 nw < 4 nw Standard Lower 20% 70% +/25 nw <+/3 nw < 80 nw Option CFT N/A 20% 70% +/63 nw <+/7 nw < 4 nw N848B Standard Option CFT Upper Lower N/A 20% 70% 20% 70% 20% 70% +/63 μw +/25 μw +/63 μw <+/7 μw <+/3 μw <+/7 μw < 4 μw < 80 μw < 4 μw N848H Standard Option CFT Upper Lower N/A 20% 70% 20% 70% 20% 70% +/6.3 μw +/2.5 μw +/6.3 μw <+/0.7 μw <+/0.3 μw <+/0.7 μw <.4 μw < 8 μw <.4 μw Effects of averaging on noise: Averaging over to 024 readings is available for reducing noise. The table below provides the measurement noise for a particular sensor with the number of averages set at 6 (for normal mode) and 32 (for x2 mode). Use the noise multiplier, for the appropriate mode (normal or x2) and number of averages, to determine the total measurement noise value. Example: N848A power sensor, normal mode, number of averages = 4 Measurement noise calculation: <80 nw x 2.75 = <220 nw No. of averages Noise multiplier Normal mode x2 mode RH is the abbreviation for relative humidity. 2. Within one hour after zero set, at a constant temperature, after a 24hour warmup of the power meter with sensor connected. 3. The number of averages at 6 for Normal mode and 32 for x2 mode, at a constant temperature, measured over a oneminute interval and two standard deviations. 8

9 Switching point The N8480 Series power sensors (standard only, ie. excluding Option CFT) have two measurement ranges: a lower power range and upper power range. The power meter automatically selects the proper power level range. To avoid unnecessary switching when the power level is near the switch point, switching point hysteresis has been added. N848A/82A/85A/87A and /AR power sensors This hysteresis causes the lower power range to remain selected until approximately 0.5 dbm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately.5 dbm as the signal level decreases. Below this power, the lower power range is selected. N848/2B power sensors This hysteresis causes the lower power range to remain selected until approximately 29.5 dbm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately 28.5 dbm as the signal level decreases. Below this power, the lower power range is selected. N848/2H power sensors This hysteresis causes the lower power range to remain selected until approximately 7.5 dbm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately 6.5 dbm as the signal level decreases. Below this power, the lower power range is selected. N848/2/5/7A and /AR excluding Option CFT N848/2B excluding Option CFT N848/2H excluding Option CFT AUTO (default range): Upper power range: Lower power range: Switching point hysteresis: AUTO (default range): Upper power range: Lower power range: Switching point hysteresis: AUTO (default range): Upper power range: Lower power range: Switching point hysteresis: 35 to +20 dbm to +20 dbm 35 to dbm 0.5 db typical 5 to +44 dbm +29 to +44 dbm 5 to +29 dbm 0.5 db typical 5 to +35 dbm +7 to +35 dbm 5 to +7 dbm 0.5 db typical 9

10 Settling time Manual filter, 0dB decreasing power step for normal and x2 modes (not across switching point) No. of averages Settling time (s) Normal mode x2 mode Auto filter, default resolution, 0dB decreasing power step for normal and x2 modes (not across switching point) x2 mode Normal mode Max dbm Typical settling times 50 ms 80 ms 400 ms 50 ms 200 ms s 20 db 0 db 0 db Sensor dynamic range 3.6s 6.6s 0 db 6.6s 3.5s 5 db Min dbm. Settling time: 0 to 99% settled readings over the GPIB Calibration factor and reflection coefficient Calibration factor (CF) and reflection coefficient (Rho) data is unique to each sensor. The CF corrects for the frequency response of the sensor. The Agilent EPM Series, EPMP Series and PSeries power meters automatically read the CF data stored in the sensor s EEPROM and use it to make the corrections. Reflection coefficient (Rho or ) relates to the according to the following formula: = + Typical measurement uncertainties of the calibration factor (CF) are listed in the following table. There is only one set of CF data used for both high and low range of each sensor. The typical measurement uncertainty data listed in the table is meant to help users on the measurement uncertainty estimation. These values are only a guideline and are not to be used in any accurate uncertainty calculations. For accurate measurement uncertainty values, please refer to the measurement report [] of the specific sensor [] Only applicable with the purchase of Option A7 or Option A6J. 0

11 Calibration factor uncertainty The typical measurement uncertainties listed are not to be taken as the maximum CF measurement uncertainties. Frequency 25ºC ± 3ºC N848A N848B N848H 00 khz to 0 MHz 0 MHz to 30 MHz 30 MHz to 500 MHz 500 MHz to.2 GHz.2 GHz to 6 GHz 6 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 26.5 GHz 26.5 GHz to 33 GHz 33 GHz to 34 GHz 34 GHz to 35 GHz 35 GHz to 40 GHz 40 GHz to 45 GHz 45 GHz to 50 GHz Frequency 25ºC ± 0ºC N848A N848B N848H 00 khz to 0 MHz 0 MHz to 30 MHz 30 MHz to 500 MHz 500 MHz to.2 GHz.2 GHz to 6 GHz 6 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 26.5 GHz 26.5 GHz to 33 GHz 33 GHz to 34 GHz 34 GHz to 35 GHz 35 GHz to 40 GHz 40 GHz to 45 GHz 45 GHz to 50 GHz Frequency 0ºC ± 55ºC N848A N848B N848H 00 khz to 0 MHz 0 MHz to 30 MHz 30 MHz to 500 MHz 500 MHz to.2 GHz.2 GHz to 6 GHz 6 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 26.5 GHz 26.5 GHz to 33 GHz 33 GHz to 34 GHz 34 GHz to 35 GHz 35 GHz to 40 GHz 40 GHz to 45 GHz 45 GHz to 50 GHz

12 Typical CF and vs. Frequency Chart shows supplemental characteristics, intended to provide additional information, useful in applying the power sensor by giving a typical but not warranted performance parameters. Cal Factor Typical CF Typical General specifications Dimensions and weight Dimensions (WxHxL) Height (H) Length (L) Width (W) Weight Operating environment Temperature Humidity Altitude Storage conditions Temperature Humidity Altitude N848A/2A: 38 mm W x 30 mm H x 30 mm L : 38 mm W x 30 mm H x 2 mm L : 38 mm W x 30 mm H x 2 mm L : 38 mm W x 62 mm H x 52 mm L : 38 mm W x 62 mm H x 52 mm L N848B/82B: 83 mm W x 4 mm H x 283 mm L N848H/82H: 38 mm W x 30 mm H x 74 mm L N848A/2A: Net: 0.8 kg (0.40 lb) Shipping: 0.90 kg (.98 lb) : Net: 0.83 kg (0.40 lb) Shipping: 0.90 kg (.98 lb) : Net: 0.54 kg (0.34 lb) Shipping: kg (.92 lb) : Net: kg (0.45 lb) Shipping: kg (2.03 lb) : Net: kg (0.45 lb) Shipping: kg (2.03 lb) N848B/82B: Net: kg (.5 lb) Shipping:.404 kg (3.09 lb) N848H/82H: Net: kg (0.52 lb) Shipping: kg (2.0 lb) 0 C to 55 C Maximum: 95% RH at 40 C noncondensing Minimum: 5% RH at 40 C noncondensing Up to 4600 m (5,000 ft) 40 C to 70 C Up to 90% RH at 65 C noncondensing Up to 4600 m (5,000 ft) 2

13 Connector Programming language Safety and EMC compliance Calibration interval Warranty N848A/82A: Ntype (male) : 3.5 mm (male) : 2.4 mm (male) N848B/82B: Ntype (male) N848H/82H: Ntype (male) : Waveguide flange UG599/U : Waveguide flange UG383/U Standard: SCPI codecompatible to ESeries sensors Option CFT: SCPI codecompatible to 8480 Series sensors IEC /EN 6326:997+A:998+A3:2003 Canada: ICES00:2004 Australia/New Zealand: AS/NZS CISPR:2004 year year. See Ordering information for available options Ordering information Power sensors Standard power sensors N848A 033 N848B N848H Other sensor options Option CFT Description Standard N848A model with EEPROM feature Standard model with EEPROM feature Standard model with EEPROM feature Standard model with EEPROM feature Standard model with EEPROM feature Standard N848B model with EEPROM feature Standard model with EEPROM feature Standard N848H model with EEPROM feature Standard model with EEPROM feature Standard model with EEPROM feature Standard model with EEPROM feature Description Frequency range 0 MHz 8 GHz 00 khz 6 GHz 0 MHz 26.5 GHz 0 MHz 33 GHz 50 MHz 50 GHz 0 MHz 8 GHz 00 khz 6 GHz 0 MHz 8 GHz 00 khz 6 GHz 26.5 GHz 40 GHz 33 GHz to 50 GHz Power range 35 to +20 dbm 35 to +20 dbm 35 to +20 dbm 35 to +20 dbm 35 to +20 dbm 5 to +44 dbm 5 to +44 dbm 5 to +35 dbm 5 to +35 dbm 35 to +20 dbm 35 to +20 dbm N8480 sensors without EEPROM feature. Calibration factor data is provided on the label attached to the power sensor. The following items are shipped as standard with every power sensor: Certificate of Calibration Operating and Service Guide Product Reference CD (contains Migration Guide, Operating and Service Guide, firmware upgrades for EPM, EPMP and PSeries power meters, and upgrade procedures) 3

14 Ordering information (continued) Accessories, calibration and documentation options Connectors Option 00 Option 200 Cables 730A 730B 730C 730D 730E 730F E9288A E9288B E9288C N97A N97B N97C Calibration Option A7 Option A6J Warranty Option R5B003C Option R5B005C Documentation Option OB Option ABJ Description TypeN (male) connector for N848A//N848B//N848H/ 3.5mm (male) connector for 2.4mm (male) connector for Waveguide connector for / APC7 (male) connector for N848A only Description For EPM Series power meters:.5 m (5 ft), grey For EPM Series power meters: 3 m (0 ft), grey For EPM Series power meters: 6. m (20 ft), grey For EPM Series power meters: 5.2 m (50 ft), grey For EPM Series power meters: 30.5 m (00 ft), grey For EPM Series power meters: 6 m (200 ft), grey *operates up to 45 C For EPM and EPMP Series power meters:.5 m (5 ft), blue For EPM and EPMP Series power meters: 3 m (0 ft), blue For EPM and EPMP Series power meters: 0 m (3 ft), blue For PSeries power meters:.5 m (5 ft) For PSeries power meters: 3 m (0 ft) For PSeries power meters: 0 m (3 ft) Description ISO 7025 calibration with test data ANSI Z540 calibration with test data Description Extension of warranty and service plan from year to 3 years Extension of warranty and service plan from year to 5 years Description English language Operating and Service Guide Japanese localization Operating and Service Guide 4

15 Where does the N8480 fit in Agilent s average power sensors offering? Signal characteristics > CW Modulated CW Pulse/ averaged AM/FM profiled Wireless standards Sensor technology Typical application examples > Themocouple sensors 8480A/B/H, N8480A/B/H, R/Q8486A, /AQ Diode sensors 8480D, V8486A, W8486A Metrology lab Radar/ navigation Mobile radio TDMA GSM EDGE NADC IDEN Avg.only cdmaone Bluetooth Avg.only WCDMA cdma2000 Avg.only 802.a/b/g MCPA HiperLan2 WiMAX Avg.only Avg.only Avg.only Avg.only Avg.only Diode sensors compensated for extended range E442A/3A FM only Twopath diodestack sensors E9300 Series Avg.only Avg.only Avg.only Avg.only N848XB Series 5 to +44 dbm Power 9 khz 00 khz 0 MHz OPT 33 N848A E9300A OPTH24 E930A E9304A OPTH8 U2004A U2002A U200A U2000A 50 MHz 2 GHz N848B E930XB Series E9300B 30 to +44 dbm E930B U200XB Series U200B 30 to +44 dbm U2000B N848XH Series N848H 5 to +35 dbm E9300H E930XA/H Series E930H 50 to +30 dbm E9300A U200XH Series 50 to +30 dbm 848XA Series 30 to +20 dbm 8483A (75ohm) N848XA Series 35 to +20 dbm E930XA Series 60 to +20 dbm U200XA Series 60 to +20 dbm E9304A U2002H U200H U2000H 4.2 GHz 6 GHz 8 GHz OPTH25 OPTH9 24 GHz 26.5 GHz 33 GHz E44XA Series E443A OPT H33 70 to +20 dbm E442A 848XD Series 70 to 20 dbm 848D 8485D 8487D Q8486D R8486D OPT33 40 GHz 50 GHz V8486A W8486A 75 GHz 0 GHz Frequency Legend N848X Average Thermocouple Sensor 848XD Average Diode Sensor 848X Thermocouple Sensor E44X Path Diode CWonly Sensor E930X 2Path Diode True Average Sensor U200X USB Sensors 5

16 Compatible power meters The N8480 Series power sensors perform accurate, repeatable average power measurements with the following power meters: Agilent N9A/2A PSeries power meters Agilent E446A/7A EPMP Series power meters Agilent N93A/4A EPM Series power meters Single (N9A) and dual (N92A) channels High resolution color display 30 MHz video bandwidth 00 Msamples/s continuous sampling rate Timegated and freerun measurement modes Rise time, fall time, pulse width, time to positive occurrence and time to negative occurrence measurements Includes predefined configurations for WiMAX, HSDPA and DME GPIB, LAN and USB interfaces Codecompatible with EPMP and EPM Series power meters Optimized for peak power measurements and CCDF statistical analysis with the PSeries power sensors Also compatible with all ESeries, N8480 Series and 8480 Series power sensors Single (E446A) and dual (E447A) channels 5 MHz video bandwidth 20 Msamples/s continuous sampling rate Timegated and freerun measurement modes Includes predefined configurations for GSM, EDGE, NADC, iden, Bluetooth, IS95 CDMA, WCDMA and cdma2000 GPIB, RS232/422 interfaces Codecompatible with EPM Series power meters Optimized for peak power measurements with the E9320 ESeries power sensors Also compatible with the E9300 and E440 ESeries, 8480 and N8480 Series power sensors Single (N93A) and dual (N94A) channels Two optional USB channels available for fourchannel measurements Frequency range of 9 khz to 0 GHz Power range of 70 dbm to +44 dbm (depending on the attached power sensor) Fast measurement speed of 400 readings/s Industry's first color LCD screen for average power meters USB and LAN/LXIC connectivity on top of the standard GPIB Automatic frequency/power sweep measurements with the optional trigger IN/OUT feature Codecompatible with 436A, 437B (N93A only) and 438A (N94A only) power meters Optimized for average power measurements with the U2000, E9300 and E440, N8480 and 8480 Series power sensors Note: The N8480 Series is also compatible with the E448B/9B Series EPM power meters. To get your existing power meters upandrunning in supporting the N8480 Series, just download their firmware upgrades online at > Technical Support > Drivers & Software > Firmware Update. Power meter EPM Series power meters EPMP Series power meters PSeries power meters Model number E448B E449B N93A N94A E446A E447A N9A N92A Compatible firmware revision A.09.0 and above A and above A.0.00 and above A.05.0 and above A and above A and above 6

17 Agilent Updates Get the latest information on the products and applications you select. Agilent Direct Quickly choose and use your test equipment solutions with confidence. Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of systemready instruments, open industry software, PCstandard I/O and global support, which are combined to more easily integrate test system development. Bluetooth is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, Inc. cdma2000 is a registered certification mark of the Telecommunications Industry Association. Used under license. WiMAX is a trademark of the WiMAX Forum. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilenttrained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial startup assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: Phone or Fax Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand Europe & Middle East Austria Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden Switzerland United Kingdom (877) (800) (42) (0) (0) * *0.25 /minute ** **0.4 /minute / (0) (9) (0) Other European Countries: Revised: July 7, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc Printed in USA, June 9, EN

N8480 Series Thermocouple Power Sensors DATA SHEET

N8480 Series Thermocouple Power Sensors DATA SHEET N8480 Series Thermocouple Power Sensors DATA SHEET Introduction The Keysight Technologies, Inc. N8480 Series thermocouple power sensors are amongst the most accurate and reliable sensors, plus they include

More information

Agilent N8480 Series Thermocouple Power Sensors

Agilent N8480 Series Thermocouple Power Sensors Agilent N8480 Series Thermocouple Power Sensors Data Sheet The N8480 Series thermocouple power sensors are amongst Agilent s most accurate and reliable sensors, plus they include EEPROM, and extended frequency

More information

Keysight Technologies N8480 Series Thermocouple Power Sensors. Data Sheet

Keysight Technologies N8480 Series Thermocouple Power Sensors. Data Sheet Keysight Technologies N8480 Series Thermocouple Power Sensors Data Sheet Introduction The Keysight Technologies, Inc. N8480 Series thermocouple power sensors are amongst the most accurate and reliable

More information

Advanced Test Equipment Rentals ATEC (2832) Keysight N8480 Series Thermocouple Power Sensors. Data Sheet

Advanced Test Equipment Rentals ATEC (2832) Keysight N8480 Series Thermocouple Power Sensors. Data Sheet Established 98 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Keysight N8480 Series Thermocouple Power Sensors Data Sheet Introduction The Keysight Technologies, Inc. N8480 Series

More information

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent U2000 Series USB Power Sensors. Data Sheet Agilent U2000 Series USB Power Sensors Data Sheet Features Perform power measurement without a power meter Frequency range from 9 khz to 24 GHz (sensor dependent) Dynamic range from 60 dbm to +20 dbm Internal

More information

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview Agilent N8480 Series Thermocouple Power Sensors Technical Overview Introduction The new N8480 Series power sensors replace and surpass the legacy 8480 Series power sensors (excluding the D-model power

More information

Agilent NFA Noise Figure Analyzer

Agilent NFA Noise Figure Analyzer Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110

More information

Agilent N1913A and N1914A EPM Series Power Meters

Agilent N1913A and N1914A EPM Series Power Meters Agilent N1913A and N1914A EPM Series Power Meters Consistent Results and Greater Capability Data Sheet As signals become more complex, it becomes more difficult to make fast, accurate power measurements.

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent Maximizing Measurement Speed Using P-Series Power Meters Agilent Maximizing Measurement Speed Using P-Series Power Meters Application Note A winning solution in the combination of bandwidth and performance 30 MHz video bandwidth Single-shot real time and repetitive

More information

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet Agilent N1911A/N191A P-Series Power Meters and N191A/N19A Wideband Power Sensors Data sheet LXI Class-C-Compliant Power Meter A P-Series power meter is a LXI Class-C-compliant instrument, developed using

More information

Agilent MXG Signal Generators

Agilent MXG Signal Generators Agilent MXG Signal Generators N5161A MXG ATE Analog N5162A MXG ATE Vector N5181A MXG Analog N5182A MXG Vector Configuration Guide This guide is to assist in the ordering process for the MXG analog and

More information

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note Agilent AN 346-2 Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note Introduction How a balanced circuit differs from an unbalanced circuit A balanced circuit

More information

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet Agilent N1911A/N191A P-Series Power Meters and N191A/N19A Wideband Power Sensors Data sheet Specification Definitions There are two types of product specifications: Warranted specifications are specifications

More information

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet Agilent N8262A P-Series Modular Power Meter and Power Sensors Data Sheet Specification Definitions There are two types of product specifications: Warranted Specifications Warranted specifications are specifications

More information

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer Application Note Minimize cost of test with the 20 GHz ENA s high performance and fast measurement speed Quickly leverage your current

More information

E-series E9300 Average Power Sensor Specifications

E-series E9300 Average Power Sensor Specifications E-series E9300 Average Power Sensor Specifications The E-series E9300 wide dynamic range, average power sensors are designed for use with the EPM family of power meters. These specifications are valid

More information

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz Technical Overview Advances in Noise Figure Accuracy N4000A Used for low noise figure devices or devices sensitive to mismatch

More information

Agilent U9397A/C FET Solid State Switches (SPDT)

Agilent U9397A/C FET Solid State Switches (SPDT) Agilent U9397A/C FET Solid State Switches (SPDT) U9397A 300 khz to 8 GHz U9397C 300 khz to 18 GHz Technical Overview Key Features Prevent damage to sensitive components with low video leakage < 10 mvpp

More information

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies Waveguide Power Sensors. Data Sheet Keysight Technologies Waveguide Power Sensors Data Sheet 02 Keysight Waveguide Power Sensors - Data Sheet Make accurate and reliable measurements in the 50 to 110 GHz frequency range with Keysight s family

More information

Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet. Product specifications and characteristics

Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet. Product specifications and characteristics Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet Product specifications and characteristics EPM series E4418B and E4419B power meters Specifications Specifications describe

More information

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth

More information

Agilent 87075C Multiport Test Set

Agilent 87075C Multiport Test Set Agilent 87075C Multiport Test Set Technical Overview A complete 75 Ω system for cable TV device manufacturers Now, focus on testing, not reconnecting! For use with the Agilent 8711 C-Series of network

More information

Agilent MXG Signal Generators

Agilent MXG Signal Generators Agilent MXG Signal Generators N5161A MXG ATE Analog N5162A MXG ATE Vector N5181A MXG Analog N5182A MXG Vector Configuration Guide This guide is to assist in the ordering process for the MXG analog and

More information

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Two-Way Radio Testing with Agilent U8903A Audio Analyzer Two-Way Radio Testing with Agilent U8903A Audio Analyzer Application Note Introduction As the two-way radio band gets deregulated, there is a noticeable increase in product offerings in this area. What

More information

Agilent U1700 Series Handheld LCR Meters

Agilent U1700 Series Handheld LCR Meters Agilent U1700 Series Handheld LCR Meters Data Sheet Test passive components conveniently, affordably and reliably with the Agilent U1700 Series LCR meters extending the tradition of industryleading benchtop

More information

Process Control Calibration Made Easy with Agilent U1401A

Process Control Calibration Made Easy with Agilent U1401A Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration

More information

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet Agilent U2741A USB Modular 5.5 Digits Digital Multimeter Data Sheet Features Makes fast measurements with up to 100 readings per second Measures up to 300 VDC with 5.5 digits resolution Introduction The

More information

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz Configuration Guide Ordering Guide The following steps will guide you through configuring your 4294A. Standard Furnished Item CD-ROM Manual

More information

Multipurpose Lab Station by Agilent Technologies

Multipurpose Lab Station by Agilent Technologies Multipurpose Lab Station by Agilent Technologies The Agilent Multipurpose Lab Station is an integrated system comprised of a: 1 2 3 4 5 6 7 8 Mixed signal oscilloscope (MSO) or digital signal oscilloscope

More information

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use Agilent 8705B Preamplifier 10 MHz to GHz Technical Overview Features db Gain 5 db Noise Figure Probe-power bias connection via probe port from Agilent s spectrum analyzers Compact Size Benchtop/General

More information

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Agilent 87C/D/E Coaxial Transfer Switches dc to 6.5, 0, 50 GHz Technical Overview High Performance Transfer Switches for Micro wave and RF Instrumentation and Systems Exceptional repeatability for more

More information

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter Application Note Introduction The Agilent 34405A is the latest member of Agilent s digital multimeter (DMM), expanding

More information

Solutions for Solar Cell and Module Testing

Solutions for Solar Cell and Module Testing Solutions for Solar Cell and Module Testing Agilent 663XB Power Supplies Connected in Anti-Series to Achieve Four-Quadrant Operation for Solar Cell and Module Testing Application Note Overview To fully

More information

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs Application Note Recently, various devices using MEMS technology such as pressure sensors, accelerometers,

More information

Agilent N432A Thermistor Power Meter

Agilent N432A Thermistor Power Meter Agilent N432A Thermistor Power Meter Data Sheet Key features Frequency range: 100 khz to 18 GHz (sensor dependent) Power range: 30 dbm (1 μw) to +10 dbm (10 mw) High accuracy ± (0.1% of reading + 0.5 μw),

More information

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters Data Sheet Basic + Good = Elegant Simplicity Features Up to 120,000 counts resolution Up to 0.012% basic DCV accuracy 11 basic measurements and

More information

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses Application Note 1591 This application note covers new tools and measurement techniques for characterizing and validating signal

More information

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms Introduction Today, during the designing of electronic components and circuits for computers, peripherals, and consumer

More information

DATA SHEET. N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors

DATA SHEET. N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors DATA SHEET N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors LXI Class-C-Compliant Power Meter A P-Series power meter is a LXI Class-C-compliant instrument, developed using LXI

More information

Agilent J7211A/B/C Attenuation Control Units

Agilent J7211A/B/C Attenuation Control Units Agilent J7211A/B/C Attenuation Control Units DC to 6 GHz, DC to 18 GHz, DC to 26.5 GHz 0 to 101/121 db attenuation range, 1 db step size Technical Overview Key Features 0.03 db insertion loss repeatability

More information

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS Agilent E4438C/E8267D Option 422 Scenario Generator for GPS Technical Overview Create GPS Scenarios with Ease The Option 422 scenario generator software enhances the functionality of the Global Positioning

More information

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and

More information

Keysight Technologies N432A Thermistor Power Meter. Data Sheet

Keysight Technologies N432A Thermistor Power Meter. Data Sheet Keysight Technologies N432A Thermistor Power Meter Data Sheet 02 Keysight N432A Thermistor Power Meter Data Sheet Why Keysight s Power Meters and Sensors? Keysight s only power meter that supports thermistor

More information

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes Data Sheet Fast, automatic and reliable characterization of switching mode power devices Today

More information

Agilent NFA Noise Figure Analyzer

Agilent NFA Noise Figure Analyzer Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110

More information

N432A Thermistor Power Meter DATA SHEET

N432A Thermistor Power Meter DATA SHEET N432A Thermistor Power Meter DATA SHEET Why Keysight s Power Meters and Sensors? Keysight s only power meter that supports thermistor mount with useful enhancements for metrology and calibration lab environments.

More information

Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz DATA SHEET

Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz DATA SHEET Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz DATA SHEET Improve your power measurement throughput Improve your power measurement throughput with the world s fastest

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors Data Sheet LXI Class-C-Compliant

More information

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N9342C Handheld Spectrum Analyzer (HSA) Agilent N9342C Handheld Spectrum Analyzer (HSA) Data Sheet Field testing just got easier The Agilent N9342C handheld spectrum analyzer (HSA) is more than easy-to-use its measurement performance gives you

More information

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V Agilent M9185A PXI Isolated D/A Converter Data Sheet 8/16-Channel 16-bit, ±16 V DISCOVER the Alternatives...... Agilent MODULAR Products Overview Introduction The Agilent M9185A is a digital/analog converter

More information

Keysight Technologies N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data Sheet

Keysight Technologies N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data Sheet Keysight Technologies N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors Data Sheet 02 Keysight N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensor Data

More information

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA Application Note Introduction The RF amplifier is a key component used in a wide variety of industries

More information

Agilent N8700 Series System DC Power Supplies

Agilent N8700 Series System DC Power Supplies Agilent N8700 Series System DC Power Supplies Models: N8731A-42A (3.3 kw), N8754A-62A (5 kw) Data Sheet 21 Models: 3300 W and 5000 W output power Up to 600 V and up to 400 A Small, high density 2 U package

More information

Agilent N5531S Measuring Receiver

Agilent N5531S Measuring Receiver Agilent N5531S Measuring Receiver Data Sheet Key measurements include: Frequency counter Absolute RF power Tuned RF level TRFL with tracking AM depth FM deviation oi M deviation Modulation rate Modulation

More information

Agilent E4428C and E4438C ESG Signal Generators

Agilent E4428C and E4438C ESG Signal Generators Agilent E4428C and E4438C ESG Signal Generators Confi guration Guide You Can Upgrade! Options can be added after initial purchase. E4428C ESG Analog Signal Generator Configuring your E4428C analog signal

More information

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform Application Note Introduction Time domain analysis (TDA) is a common method for evaluating transmission lines and has

More information

Agilent N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned

More information

Agilent 86142B and 86146B Optical Spectrum Analyzers

Agilent 86142B and 86146B Optical Spectrum Analyzers Agilent 86142B and 86146B Optical Spectrum Analyzers Technical Overview Full-Feature Optical Spectrum Analyzer Exhibits excellent speed and dynamic range with convenient and powerful user interface. Filter

More information

Agilent U1240 Series Handheld Digital Multimeters

Agilent U1240 Series Handheld Digital Multimeters Agilent U1240 Series Handheld Digital Multimeters Data Sheet Helping You Check and Fix More Installation and Maintenance Bugs Key Features Check more, fix more ACI, diode, continuity tests Capacitance,

More information

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and configuration

More information

Agilent U9391C/F/G Comb Generators

Agilent U9391C/F/G Comb Generators Agilent U9391C/F/G Comb Generators U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview Key Features Excellent amplitude and phase flatness enable it to be

More information

Keysight Technologies N432A Thermistor Power Meter. Data Sheet

Keysight Technologies N432A Thermistor Power Meter. Data Sheet Keysight Technologies N432A Thermistor Power Meter Data Sheet 02 Keysight N432A Thermistor Power Meter Data Sheet Why Keysight s Power Meters and Sensors? Keysight s only power meter that supports thermistor

More information

Keysight U8480 Series

Keysight U8480 Series Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz Data Sheet 02 Keysight U8480 Series USB Thermocouple Power Sensors Data Sheet Improve your power measurement throughput

More information

Agilent EPM Series Power Meters

Agilent EPM Series Power Meters Agilent EPM Series Power Meters The standard just got better! What s new? Fast measurement speeds (up to 200 readings per second) Wide dynamic range sensors (-70 dbm to +44 dbm), sensor dependent Calibration

More information

Agilent Digital Modulation Lab Station

Agilent Digital Modulation Lab Station Agilent Digital Modulation Lab Station Agilent Digital (I/Q) Modulation Lab Station The Agilent Digital Modulation Lab Station is an integrated solution that can be used for easy generation, accurate measurement

More information

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors Product Overview The power measurement solution you ve been looking for Ideal for today

More information

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal N7550 Series, 2-port

More information

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Agilent 2-Port and 4-Port PNA-X Network Analyzer Agilent 2-Port and 4-Port PNA-X Network Analyzer N5244A - MHz to 43.5 GHz N5245A - MHz to 5. GHz with Option H29 Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN

More information

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth Agilent 8703B Lightwave Component Analyzer Technical Specifications 50 MHz to 20.05 GHz modulation bandwidth 2 The 8703B lightwave component analyzer is a unique, general-purpose instrument for testing

More information

Agilent NFA Noise Figure Analyzer

Agilent NFA Noise Figure Analyzer Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110

More information

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N9342C Handheld Spectrum Analyzer (HSA) Agilent N9342C Handheld Spectrum Analyzer (HSA) 100 khz to 7 GHz (tunable to 9 khz) Data Sheet Field testing just got easier www.agilent.com/find/hsa If you are making measurements in the field, the Agilent

More information

Keysight E5063A ENA Series Network Analyzer

Keysight E5063A ENA Series Network Analyzer Keysight E5063A ENA Series Network Analyzer 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz Configuration Guide 02 Keysight E5063A ENA Series Network Analyzer - Configuration Guide Ordering Guide

More information

Agilent E8257D PSG Microwave Analog Signal Generator

Agilent E8257D PSG Microwave Analog Signal Generator Agilent E8257D PSG Microwave Analog Signal Generat Configuration Guide You Can Upgrade! Options can be added after initial purchase. This guide assists in the dering process of the E8257D PSG microwave

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators Technical Overview High accuracy Low SWR Broadband

More information

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview Agilent 4287A RF LCR Meter 1 MHz - 3 GHz Technical Overview High-Speed RF LCR Meter Anticipating Next Generation Test Needs The Agilent 4287A is a high performance RF LCR meter best fit to production line

More information

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices Application Note Introduction The U2300A Series and U2500A Series data acquisition device (DAQ) families are

More information

Agilent First-generation MXG Signal Generators

Agilent First-generation MXG Signal Generators Agilent First-generation MXG Signal Generators N5181A MXG Analog N5182A MXG Vector Configuration Guide You Can Upgrade! Options can be added after initial purchase. This guide is to assist in the ordering

More information

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size Data Sheet Features 1-Slot, C-size, message-based DCV, ACV, DCI, ACI, 2/4-wire Ω, frequency, period NULL, MIN/MAX, LIMIT, db, dbm 1000 reading/s

More information

Evaluating Oscilloscope Bandwidths for your Application

Evaluating Oscilloscope Bandwidths for your Application Evaluating Oscilloscope Bandwidths for your Application Application Note 1588 Table of Contents Introduction....................... 1 Defining Oscilloscope Bandwidth..... 2 Required Bandwidth for Digital

More information

Agilent PN 4395-1 Agilent 4395A Network/Spectrum/ Impedance Analyzer Silicon Investigations Repair Information - Contact Us 920-955-3693 www.siliconinvestigations.com ADSL Copper Loop Measurements Product

More information

Agilent E6651A Mobile WiMAX Test Set

Agilent E6651A Mobile WiMAX Test Set Agilent E6651A Mobile WiMAX Test Set Preliminary Technical Overview Accelerate time-to-market for your IEEE802.16e subscriber station designs The E6651A represents a significant breakthrough in Mobile

More information

MXG X-Series Signal Generator N5183B Microwave Analog

MXG X-Series Signal Generator N5183B Microwave Analog MXG X-Series Signal Generator N5183B Microwave Analog Configuration Guide This configuration guide will help you determine which performance, software applications, accessories, and services to include

More information

Agilent E4428C and E4438C ESG Signal Generators. Confi guration Guide

Agilent E4428C and E4438C ESG Signal Generators. Confi guration Guide Agilent E4428C and E4438C ESG Signal Generators Confi guration Guide E4428C ESG Analog Signal Generator Configuring your E4428C analog signal generator The following steps will guide you through configuring

More information

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide Keysight Technologies NFA Noise Figure Analyzer Configuration Guide Noise Figure Analyzer Overview Over 50 years of noise figure leadership Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz

More information

MXG Analog Signal Generator Express Configurations

MXG Analog Signal Generator Express Configurations MXG Analog Signal Generator Express Configurations N5181AEP MXG RF Analog (100 khz to 1, 3 or 6 GHz) N5183AEP MXG MW Analog (100 khz to 20 GHz) Technical Overview When you just can t wait, get the same

More information

Keysight Technologies USB Preamplifiers

Keysight Technologies USB Preamplifiers Keysight Technologies USB Preamplifiers U77/A 1 MHz to 4 GHz U77/C 1 MHz to 6. GHz U77/F to GHz Technical Overview Keysight USB Preamplifiers U77A/C/F - Technical Overview Key Features and Benefits Automatic

More information

Agilent U8903A Audio Analyzer

Agilent U8903A Audio Analyzer Agilent U8903A Audio Analyzer Fast and accurate multi-channel audio analysis made affordable Ideal replacement for the HP 8903B! 5.7-inch color display Soft keys for easy function selection One-button

More information

N9051A Pulse Measurement Software

N9051A Pulse Measurement Software N9051A Pulse Measurement Software X-Series Signal Analyzers and PSA Series Spectrum Analyzers Technical Overview Characterize pulse performance using a wide range of parameters including pulse width, rise/fall

More information

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches Application Note Introduction The evolution of components and modules is unstoppable because of increasing requirements from

More information

Agilent 8762F Coaxial Switch 75 ohm

Agilent 8762F Coaxial Switch 75 ohm Agilent 8762F Coaxial Switch 75 ohm Technical Overview DC to 4 GHz Exceptional repeatability over 1 million cycle life Excellent isolation The 8762F brings a new standard of performance to 75 ohm coaxial

More information

Agilent InfiniiMax III probing system

Agilent InfiniiMax III probing system Agilent InfiniiMax III probing system Data Sheet World s highest speed and highest performing probe system Full 30 GHz bandwidth to the probe tip Industry s lowest probe and scope system noise Industry

More information

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Agilent N9340B Handheld Spectrum Analyzer (HSA) Agilent N9340B Handheld Spectrum Analyzer (HSA) Configuration Guide This configuration guide will help you determine which performance options, measurement application software, accessories, and services

More information

AC/DC Current Probe TCP0150 Datasheet

AC/DC Current Probe TCP0150 Datasheet AC/DC Current Probe TCP0150 Datasheet Low noise and DC drift Provides automatic units scaling and readout on the oscilloscope's display Remote GPIB/USB probe control through the oscilloscope Split-core

More information

Agilent ENA 2 and 4 Port RF Network Analyzers

Agilent ENA 2 and 4 Port RF Network Analyzers Agilent ENA 2 and 4 Port RF Network Analyzers Data Sheet E5071C-240/440 9 khz to 4.5 GHz E5071C-245/445 0 khz to 4.5 GHz (with bias-tees) E5071C-280/480 9 khz to 8.5 GHz E5071C-285/485 0 khz to 8.5 GHz

More information

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz Agilent E5061B Network Analyzer 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz E5061B responds to various measurement needs, - from LF to RF The Agilent E5061B is a member of the industry standard ENA Series network

More information

Agilent N4916B De-emphasis Signal Converter

Agilent N4916B De-emphasis Signal Converter Agilent N4916B De-emphasis Signal Converter Data Sheet, Version 1.1 NEW! Extended bit rate to 14.2 Gb/s Accurately characterize your multi-gigabit serial interfaces with the 4-tap de-emphasis signal converter

More information

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches P9400A 100 MHz to 8 GHz PIN transfer switch P9400C 100 MHz to 18 GHz PIN transfer switch Technical Overview Key Features Minimize

More information

Agilent 81180A Arbitrary Waveform Generator

Agilent 81180A Arbitrary Waveform Generator Agilent 81180A Arbitrary Waveform Generator Specification 1.0 When waveform resolution matters test with confidence 4.2 GSa/s Arbitrary Waveform Generator with 12 bit vertical resolution 1 81180A at a

More information

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent E8247/E8257C PSG CW and Analog Signal Generators Agilent E8247/E8257C PSG CW and Analog Signal Generators Configuration Guide E8257C PSG analog signal generator Agilent Microwave PSG CW/Analog signal generators options Step 1. Choose type of signal generator

More information