ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3
|
|
- Timothy Baldwin
- 5 years ago
- Views:
Transcription
1 ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3 Electrical and ITS Engineering September 2018
2 2300 ELECTRONIC MESSAGE SIGNS 2301 PERMANENT ELECTRONIC MESSAGE SIGNS 2302 PORTABLE ELECTRONIC MESSAGE SIGNS
3 Section 2300 Electronic Message Signs Electrical and ITS Engineering June 2004 (Updated September 2018)
4 2300 ELECTRONIC MESSAGE SIGNS 2301 PERMANENT DYNAMIC MESSAGE SIGNS SCOPE MINISTRY APPROVED PRODUCTS GENERAL CHARACTERISTICS DETAILED HARDWARE STANDARDS PORTABLE DYNAMIC MESSAGE SIGNS SCOPE MINISTRY APPROVED PRODUCTS GENERAL CHARACTERISTICS DETAILED HARDWARE STANDARDS LIST OF TABLES TABLE 1: LIST OF NEMA TS APPLICABLE SECTIONS, EXCEPTIONS AND ADDITIONS... 6 TABLE 2: LIST OF NEMA TS APPLICABLE SECTIONS, EXCEPTIONS AND ADDITIONS Electrical & Signing Materials Standards Page 4
5 SCOPE 2301 PERMANENT DYNAMIC MESSAGE SIGNS.1 This specification shall apply to Fixed-Location Dynamic Message Signs (DMS)..2 DMS shall refer to Variable Message Signs (VMS) as defined in NEMA TS Fixed-Location DMS refers to a DMS mechanically attached to a non-portable support structure..4 The Fixed-Location Dynamic Message Sign, as described above, may be alternately referred to as product, fixed-location DMS, DMS or sign in this specification MINISTRY APPROVED PRODUCTS.1 Only products that are listed on the Ministry Recognized Products List are acceptable for use. Approved products can be found on the Ministry engineering website at: ok.pdf.2 See Volume 1, Chapter 102 of the Ministry Electrical and Signing Materials Standards for the product approval process. This document can be found on the Ministry engineering website at: ng/2003_material_standards/volume_1/2003_material_standards-volume_1.pdf GENERAL CHARACTERISTICS.1 This Sub-section describes general product characteristics only. Detailed hardware standards shall be as per NEMA TS with noted exceptions and additions as described in and listed in Table 1..2 The sign primary power source shall be single phase 120V AC..3 The sign display shall be line matrix, yellow LEDs as defined in the NEMA TS-4 specification (Table 5.5.1)..4 The sign shall have the capability for both local and remote control..5 The product must be compatible with the Ministry Intelligent Transportation System (ITS) operated from the Regional Traffic Management Centre in Coquitlam. The supplier shall demonstrate to Ministry Electrical and ITS Engineering personnel that the product is compatible..6 The permanent DMS shall have the capability to communicate using the NTCIP protocol.
6 PERMANENT DYNAMIC MESSAGE SIGNS DETAILED HARDWARE STANDARDS.1 The product shall conform to all applicable sections and sub-sections of the latest version of NEMA TS Hardware Standards for Dynamic Message Signs (DMS), with NTCIP Requirements, including amendments. This document may be purchased from the NEMA website at Table 1 lists the applicable sections of the NEMA standard noted above, as well as any exceptions or additions. Sections without exceptions or additions shall apply in full. Table 1: List of NEMA TS Applicable Sections, Exceptions and Additions 1 All No exceptions or additions. 2 All No exceptions or additions Does not apply. Walk in enclosures are not permitted Sign shall be front access. Add: The weight of the entire sign assembly, excluding the backboard, shall not exceed 200kg Does not apply Does not apply Does not apply. 3.3 Does not apply Reference to National Electrical Code shall be changed to Canadian Electrical Code Reference to National Electrical Code shall be changed to Canadian Electrical Code Does not apply Does not apply. All Only sub-sections referring to Light Emitting Technology shall apply. Light Emitting Technology shall be strictly limited to Light Emitting Diode (LED) technology. Add: The sign shall utilize yellow (as defined in table 5.5.1) LED s exclusively for message display (LED hybrid technology is not permitted). The viewing angle or cone of vision for each pixel shall be a minimum of Type Class e as defined in Table 5.3 +/- 15 degrees horizontal and -10 degrees vertical. Add: The sign display shall be line-matrix and shall have the capability to 5.6 display two lines of 20 characters, each character being composed of 5 X 7 pixels and being 450mm (18 inches) in height. Pixels shall be composed of a minimum of four LEDs. 6.1 Only Sub-sections referring to Line Matrix Signs shall apply. Add: Each line shall be composed of a minimum of 7 modules (minimum per sign). 6.2 Does not apply. 6.3 No exceptions or additions. Electrical & Signing Materials Standards Page 6
7 PERMANENT DYNAMIC MESSAGE SIGNS Does not apply. 6.5 Does not apply Add: DMS Cabinet shall comply fully with all requirements of Ministry Material Standards Volume 1, Chapter Reference to UL shall be replaced with ULC or CSA Does not apply Does not apply Does not apply Add: The sign shall have the capability to communicate over the following media: 1. Direct serial. 2. Serial using fixed subscriber line, dial-up cellular or satellite telephone line. 3. Internet Protocol (IP). The Vendor shall supply one modem, of the applicable type, plus interconnect cabling per sign. For wireless applications, the Vendor shall supply one Ministry-approved modem, plus antenna, power supply and interconnect cabling per sign. The Vendor is ultimately responsible to ensure that the supplied modem is fully compatible with the specified protocol application Add: The Vendor shall supply a list of supported protocols and object definitions Add: Local messaging shall typically be used only for maintenance purposes. Add: Unless otherwise specified in the Special Provisions, local messaging shall typically be used only for maintenance purposes. Normal operation shall be to download an immediate message from the control center. Add: Each NTCIP Component covered by this specification shall implement the most recent version of the standard that is at the stage of Recommended or higher as of April 2004, including approved or recommended amendments. It is the responsibility of the vendor to monitor NTCIP activities to discover any more recent documents. The vendor shall supply a list of supported protocols and object definitions. Add: The sign shall support both Portable Maintenance Computer and local control panel interfaces. The local control panel interface shall be able to display local library 8.11 messages without the use of a computer or hand-held programming device. The vendor shall supply software necessary to facilitate local control of the sign with a Portable Maintenance Computer Does not apply Does not apply. Electrical & Signing Materials Standards Page 7
8 PERMANENT DYNAMIC MESSAGE SIGNS Add: If required by inclusion in the Special Provisions, backup power may be used to maintain operation of the sign during power line failures. If so, the sign shall continue to display the current message until line power is restored or until the backup power supply is exhausted, which ever occurs first. The sign controller shall provide alarm indications to the CC for both 9 line power failure and backup power failure. The sign display shall be blanked at a backup voltage level sufficient to maintain sign controller and communications operation for a further 90 minutes Add: The Special Provisions shall list the required sign operation during communication link failures Reference to NEC shall be changed to CEC. Add: Auxiliary equipment, such has heating, ventilation and GFCI receptacle shall be fed by circuits separate from the sign controller or display. Failure of an auxiliary circuit shall not affect sign operation. Backup power shall be provided in the form of an Uninterruptible Power Supply (UPS) capable of powering the sign and associated electronics for up to 90 minutes during a power failure The vendor shall engage a third-party source to perform the conformance testing Add: If the vendor has never previously supplied a permanent DMS product to the Ministry, the vendor shall supply a sample unit for testing and evaluation purposes. The sample unit shall consist of the following: a module arrangement capable of displaying a minimum of three characters (minimum of two modules required); controller unit; hand held programming unit; vendor s sign control software package; and all mounting rails, connecting components, and other materials and equipment required to provide a functional sample sign. The sample unit shall be returned to the vendor upon completion of the evaluation Add: For each section, the Vendor shall qualify the level of compliance as follows: 1. Fully complies. 2. Complies with exceptions (vendor shall describe any exceptions). 3. Does not comply. The Ministry reserves the right to accept or reject any product based on its level of compliance. False declarations of compliance are grounds for rejection of any product Add: The Vendor shall supply System Diagrams Add: The Vendor shall supply Wiring Diagrams Add: The Vendor shall supply Cabinet Shop drawings to the Ministry for approval prior to fabrication. The Vendor shall supply sign mounting detail drawings, in AutoCAD.dwg format, signed by a registered Structural Engineer, prior to fabrication. An example of a suitable format is shown in Ministry Material Standard drawing MSxxxxxxx Replace with: The Vendor shall supply a written declaration of compliance as described in 11.4 above. Electrical & Signing Materials Standards Page 8
9 PERMANENT DYNAMIC MESSAGE SIGNS Replace with: The Vendor shall supply the MIB information for the signs Add: The Vendor shall supply Configuration Information Add: Test results are not required unless requested in writing by the Ministry representative. 12 Add: The maximum paper size for schematics, layouts, etc. is 11 x17 and 12.3 all such documentation shall be single-sided Add: A service manual shall be supplied with each sign Add: A trouble shooting manual shall be supplied with each sign Add: An operators manual shall be supplied with each sign. Electrical & Signing Materials Standards Page 9
10 SCOPE 2302 PORTABLE DYNAMIC MESSAGE SIGNS.1 This specification shall apply to portable Dynamic Message Signs (DMS)..2 DMS shall refer to Variable Message Signs (VMS) as defined in NEMA TS Portable DMS shall refer to a DMS that can be moved easily and used in applications such as construction sites, special events, or as a temporary advisory sign. The portable DMS shall be designed with electrical and mechanical characteristics that support such mobility and autonomous operation..4 The portable Dynamic Message Sign, as described above, may be alternately referred to as product, portable DMS, DMS or sign in this specification MINISTRY APPROVED PRODUCTS.1 Only products that are listed on the Ministry Recognized Products List are acceptable for use. Approved products can be found on the Ministry engineering website at: ok.pdf.2 See Volume 1, Chapter 102 of the Ministry Electrical and Signing Materials Standards for the product approval process. This document can be found on the Ministry engineering website at: ng/2003_material_standards/volume_1/2003_material_standards-volume_1.pdf
11 PORTABLE DYNAMIC MESSAGE SIGNS GENERAL CHARACTERISTICS.1 This Sub-section describes general product characteristics only. Detailed hardware standards shall be as per NEMA TS with noted exceptions and additions as described in and listed in Table 2..2 The sign shall be trailer mounted and fully transportable..3 The sign primary power source shall be solar..4 The sign display shall be full matrix, yellow/orange LED..5 The sign shall have the capability for both local and remote control..6 The product must be compatible with the Ministry Intelligent Transportation System (ITS) operated from the Regional Traffic Management Centre in Coquitlam. The supplier shall demonstrate to Ministry Electrical and ITS Engineering personnel that the product is compatible..7 The portable DMS shall have the capability to communicate using the NTCIP protocol DETAILED HARDWARE STANDARDS.1 The product shall conform to all applicable sections and sub-sections of the latest version of NEMA TS Hardware Standards for Dynamic Message Signs (DMS), with NTCIP Requirements, including amendments. This document may be purchased from the NEMA website at Table 2 lists the applicable sections of the NEMA standard noted above, as well as any exceptions or additions. Sections without exceptions or additions shall apply in full. Table 2: List of NEMA TS Applicable Sections, Exceptions and Additions. 1 All No exceptions or additions. 2 All No exceptions or additions. 3.1 No exceptions or additions. 3.2 Does not apply. 3.3 Add: The axle shall be torsion-flex type construction. The tires shall be 381mm (15 ) Load Range C or better Add: The leveling devices shall be permanently mounted to the trailer frame Add: The hitch shall be 51mm (2 ) ball type. The tongue shall be removable using a quick-disconnect method New: The trailer shall be equipped with suitably rated surge or electric brakes. Electrical & Signing Materials Standards Page 11
12 PORTABLE DYNAMIC MESSAGE SIGNS Add: All metal surfaces shall be primed and powder coated Add: Battery enclosures shall be rust-proof Add: The sign shall use solar power as the primary power source. The solar array shall be able to produce a minimum of 420 Watts and shall tilt and rotate independently of the sign display enclosure. Add: The sign shall have a battery bank with a total minimum capacity of A-Hr. at 12 VDC The battery charger or inverter/charger, as applicable, for normal solar charging or external backup charging shall be rated between 50 and 70A at 12 VDC. Add: The sign shall have the capability to charge the batteries from an alternate backup power supply, as required to augment the capability of the solar array during periods of reduced charging time, including external 120 Vac power supply and/or backup power generator. 4 All No exceptions or additions. All Only Sub-sections referring to Light Emitting Technology shall apply Add: The sign shall utilize yellow (as defined in table 5.5.1) LED s exclusively for message display (LED hybrid technology is not permitted). The viewing angle or cone of vision for each pixel shall be a minimum of Type Class e as defined in Table 5.3 +/- 15 degrees horizontal and -10 degrees vertical. 5.6 Add: The sign display shall be full-matrix and shall have the capability to display three lines of eight characters, each character being composed of 5 x 7 pixels and being 450mm (18 inches) in height. 6.1 Only Sub-sections referring to Line Matrix Signs shall apply. 6.2 Does not apply No exceptions or additions. 6.4 Does not apply. 6.5 Does not apply. 7 All No exceptions or additions Does not apply Does not apply Does not apply Add: The sign shall have the capability to communicate over the following media: 4. Dial-up cellular or satellite telephone line. 5. CDMA 1X protocol cellular telephone (IP-based). The Vendor shall supply one modem, plus antenna (if required), power supply and interconnect cabling per sign. For 1X protocol applications, the Vendor shall supply one Sierra Wireless MP 555 GPS modem, or Ministry-approved equivalent, plus antenna, power supply and interconnect cabling per sign. The Vendor is ultimately responsible to ensure that the supplied modem is fully compatible with the specified protocol application. Electrical & Signing Materials Standards Page 12
13 PORTABLE DYNAMIC MESSAGE SIGNS Add: The Vendor shall supply a list of supported protocols and object definitions Add: The sign shall have the capability for both local and remote control and both Centralized and Local Messaging shall be supported Add: The local message library shall be able to store a minimum of 16 user-defined messages Add: Each NTCIP Component covered by this specification shall implement the most recent version of the standard that is at the stage of Recommended or higher as of April 2004, including approved or recommended amendments. It is the ultimate responsibility of the vendor to monitor NTCIP activities to discover any more recent documents. The vendor shall supply a list of supported protocols and object definitions Add: The sign shall support both Portable Maintenance Computer and local control panel interfaces. The local control panel interface shall be able to display local library messages without the use of a computer or hand-held programming device. The vendor shall supply software necessary to facilitate local control of the sign with a Portable Maintenance Computer Does not apply Does not apply. 10 All No exceptions or additions Add: The Vendor shall supply a written declaration indicating the level of compliance of his or her product with each of the applicable sections of this specification. For each section, the Vendor shall qualify the level of compliance as follows: 4. Fully Complies. 5. Complies with Exceptions (Vendor shall describe any exceptions). 6. Does Not Comply. The Ministry reserves the right to accept or reject any product based on its level of compliance. False declarations of compliance are grounds for rejection of any product Add: The Vendor shall supply System Diagrams Add: The Vendor shall supply Wiring Diagrams Replace with: The Vendor shall supply a written declaration of compliance as described in 11.4 above Replace with: The Vendor shall supply the MIB information for the signs Add: The Vendor shall supply Configuration Information Add: Test results are not required unless requested in writing by the Ministry representative Add: The maximum paper size for schematics, layouts, etc. is 11 x17 and all such documentation shall be single-sided. Electrical & Signing Materials Standards Page 13
14 PORTABLE DYNAMIC MESSAGE SIGNS Add: A service manual shall be supplied with each sign Add: A trouble shooting manual shall be supplied with each sign Add: An operator manual shall be supplied with each sign. Electrical & Signing Materials Standards Page 14
RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#
RCF 3.4 Portable Traffic Signal - Technical Specifications Signal Controller Hardware Each signal controller shall be capable of providing the following feedback information to the user: Audible low battery
More informationVariable Message Sign Trailers
Variable Message Sign Trailers Frequently Asked Questions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. What standard are the VMS
More informationHT1100 Satellite Modem User Guide
HT1100 Satellite Modem User Guide 1039650-0001 Revision C October 11, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems,
More informationAPPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID
APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 BIDDER INSTRUCTIONS: All Bidder pricing must be based on the Sample Product provided in Appendix H Mandatory Requirements. Any category in Appendix H that
More informationSECTION GPS WIRELESS CLOCK SYSTEMS
PART 1 GENERAL 1.1 SECTION INCLUDES A. G.P.S. Receiver B. Primary Transmitter C. Satellite Transmitter D. Analog Clocks E. Digital Clocks 1.2 REGULATORY REQUIREMENTS SECTION 27 53 13 GPS WIRELESS CLOCK
More informationVoicestar T100 Series Specifications for Solar Powered Highway Advisory Radio
AMERICAN SIGNAL COMPANY 2755 Bankers Industrial Drive Atlanta, GA 30360 Phone: 770-448-6650 Fax: 770-448-8970 Voicestar T100 Series Specifications for Solar Powered Highway Advisory Radio 032110 1.0 SCOPE
More informationCONSTRUCTION SPECIFICATION FOR PORTABLE TEMPORARY TRAFFIC SIGNALS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 708 November 2016 CONSTRUCTION SPECIFICATION FOR PORTABLE TEMPORARY TRAFFIC SIGNALS TABLE OF CONTENTS 708.01 SCOPE 708.02 REFERENCES 708.03 DEFINITIONS
More informationSPECIAL PROVISION Description of Project, Scope of Contract and Sequence of Work
2004 Specifications CSJ 0110-04-166 SPECIAL PROVISION 000--363 Description of Project, Scope of Contract and Sequence of Work 1. General. The work to be performed on this project consists of furnishing,
More informationSPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem
1993 Specifications CSJ s 0902-48-442 & 0902-48-432 SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem 1. General. This Item shall govern for the furnishing and installation of Spread Spectrum Wireless
More informationSPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem
1993 Specifications CSJ 2266-02-095 SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem
More informationDPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters
DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters Section [26 35 26][16280] Active Harmonic Filters (Low Voltage) Part 1 General 1.1 Summary A. Scope: Provide design and engineering, labor,
More informationSPECIAL SPECIFICATION 6734 RS-232 Optical Modem
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem (OTR) in
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER OPR:DJA 1 of 5 C&T:APPR:JAR:DBP:09-01-11 FHWA:APPR:09-01-11 a. Description. This work consists
More informationMid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.
More informationAUTOMATIC WEATHER AND HYDROLOGICAL STATIONS
AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS METEODATA/HYDRODATA-3000C SERIES Brochure nº 9722.0044 GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel. +34 91 450 51 18 Fax +34 91 459 46
More informationM-0418 REV:0
1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that
More informationEMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION
CITY OF LACEY Community & Economic Development Department 420 College Street SE Lacey, WA 98503 (360) 491-5642 CASH OR CHECK ONLY PLEASE EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION FOR INSTALLATION/MODIFICATION
More informationSECTION CABLE TRAYS
SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationSection 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General
Section 16621A - AUTOMATIC TRANSFER SWITCH Part 1 General 1.01 One 600 Amp, 3 Phase, 480 Volt Automatic Transfer Switch (ATS) shall be provided with gasketed enclosure. The ATS shall consist of an inherently
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE January 15, 2016 919.01 Traffic Signal Cabinet and Controller Unit General Requirements 919.02 Approved
More informationROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO
ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO ACC 1 Flow Sensor (HFS): Reports actual flow Put an end to flow emergencies forever. To bring real-time flow sensing to the ACC,
More informationJOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide
JOINT STOCK COMPANY MULTICHANNEL RECEIVER RI-4010M (version RM1-60619) User guide Safety requirements Before using the multichannel receiver RI-4010M read this user guide and follows safety requirements!
More informationArchitectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System
Architectural/Engineering Specification for a Microwave Perimeter Intrusion Detection System µltrawave Disclaimer Senstar, and the Senstar logo are registered trademarks, and µltrawave, Silver Network
More informationBrochure nº
A U T O M A T I C W E A T H E R A N D H Y D R O L O G I C A L S T A T I O N S M E T E O D ATA / H Y D R O D ATA-3 0 0 0 C S E R I E S GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel.
More informationENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013
ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the
More informationSECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION
SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from
More informationCity of Irvine California Signal Booster Ordinance
City of Irvine California Signal Booster Ordinance CHAPTER 6. PUBLIC SAFETY RADIO SYSTEM COVERAGE Sec. 5-9-601. Intent and purpose. The intent of the chapter is to provide a regulatory framework for the
More informationSECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS
510.1 Emergency responder radio coverage in new buildings. Approved radio coverage for emergency responders shall be provided within all buildings meeting any one of the following conditions: 1. There
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationWireless Gas Detection System
Wireless Gas Detection System Sensidyne SensCast Brochure Rev.A Wireless Gas Detection System The Sensidyne SensCast Wireless Monitoring System consists of 1-32 battery-powered SensCast Transmitters and
More informationConnecting Mains Electrical Power
Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required
More informationSERIES K: PROTECTION AGAINST INTERFERENCE
International Telecommunication Union ITU-T K.49 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2005) SERIES K: PROTECTION AGAINST INTERFERENCE Test requirements and performance criteria for voice
More informationCapstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:
Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Technical Reference Capstone MicroTurbine Electrical Installation 410009 Rev F (October 2013) Page 1 of 31 Capstone Turbine Corporation
More informationMOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION
MOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION P a g e 1 North Lawrence Community Schools October 1, 2012 P a g e 2 Table of Contents TABLE OF CONTENTS... 2 GENERAL SYSTEM OVERVIEW... 3 REQUIRED
More informationPAPI Infrared Operation Overview
PAPI Infrared Operation Overview USER MANUAL SUPPLEMENT Technical Support: Email: customerservice@carmanah.com Toll Free: 1.877.722.8877 (US & Canada) Worldwide: 1.250.380.0052 Fax: 1.250.380.0062 Web:
More information2.1. Description: A bank of batteries forming a 12 VDC system shall power the unit.
AMERICAN SIGNAL COMPANY 2755 Bankers Industrial Drive Atlanta, GA 30360 Phone: 770-448-6650 Fax: 770-448-8970 T-25 Portable Solar Charged Mast Trailer Specifications For use with AMSIG Changeable Message
More informationSPECIAL SPECIFICATION 6744 Spread Spectrum Radio
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 1. Description. Furnish and install spread spectrum radio system. 2. Materials. Supply complete manufacturer specifications
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor
1993 Specifications CSJ 0008-12-071 SPECIAL SPECIFICATION ITEM 6550 Drop/Insert Multiplexor/Demultiplexor 1.0 Description. This Item shall govern for the furnishing and installation of intelligent drop/insert
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems
More informationUpdate of GPS systems technical specifications and challenges
Update of GPS systems technical specifications and challenges GPS Communication Power Bjorn Johns September 7, 2005 Polar Technology Workshop Washington, DC GPS receivers State-of-the-art in 2005: Power:
More informationwireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution
wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution smart grid n automated meter infrastructure n distribution Ventev s product solutions
More informationSPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit
1993 Specifications SPECIAL SPECIFICATION 1201 12 Inch LED Traffic Signal Lamp Unit 1. Description. This specification describes the minimum acceptable design and performance requirements for a twelve
More informationSPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK
SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,
More informationAMU-214 Auxiliary Monitor Unit Operations Manual
AMU-214 Auxiliary Monitor Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE AMU-214 SERIES ITS CABINET AUXILIARY MONITOR UNIT. REVISION: SEPTEMBER 2008 pn 888-0214-001 THE AMU-214 SERIES AUXILIARY
More informationS.W.A.T. World Leader in supplying S.W.A.T Equipment &Training SNIPER MANAGEMENT SYSTEMS
SNIPER MANAGEMENT SYSTEMS The SNIPER MANAGEMENT SYSTEM is a real time integrated system video, audio and data communications which allows the Commanding officer in charge of the operation to be placed
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More informationTrusted Power Distribution Unit MCB 24 Vdc
PD-T8292 Trusted Trusted Power Distribution Unit MCB 24 Vdc Product Overview The dual 5-channel Trusted Power Distribution Unit Miniature Circuit Breaker (MCB) 24 V is designed for N+1 or 100 % redundant
More informationCP /240-MC4 User Manual
CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...
More informationSPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment
1995 Metric CSJ's 1047-03-056 & 0008-08-066 SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationTel: Fax:
Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie
More informationCLARK COUNTY FIRE CODE AMENDMENTS
CLARK COUNTY FIRE CODE AMENDMENTS SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM is amended to read as follows: SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM 510.1 Emergency responder radio
More informationPortable Signals: INDOT Design Guidance and Specifications
: INDOT Design Guidance and Specifications Joe Bruno, P.E. Traffic Administration, INDOT March 7, 2017 Presentation Overview Background Design Manual 83-5.0 and Design Memo 16-06 Cost and Pay Item Info
More informationEmergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:
Sunnyvale 2013 Fire Code Section 510 16.52.510. Emergency responder radio coverage. (a) Emergency responder radio coverage in new buildings. California Fire Code Section 510.1 is hereby amended to read:
More informationContinuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3
Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic
More informationExhibit 8 User Manual. 8 Product Functional Requirements (User Manual)
Ground Systems Division User Manual Motorola Customer Premise Equipment (CPE) Model No. LT 20M-00 8 Product Functional Requirements (User Manual) 8.1 Scope The requirements described herein are functional
More informationSPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor
1993 Specifications CSJ 0177-11-131 SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor 1. Description. This Item shall govern for for the furnishing and installation of intelligent drop/insert
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring
More informationSPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data
2004 Specifications CSJ 0617-01-169 SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data 1. Description. This Item shall govern for the furnishing and installation of Video optical transceiver
More informationCHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE INTENT AND PURPOSE DEFINITIONS USE AND OCCUPANCY EXEMPTIONS.
CHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE 8950 - INTENT AND PURPOSE The intent of the chapter is to provide a regulatory framework for the purpose of providing effective 800 MHz Countywide Coordinated
More informationGEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax
A U T O M A T I C W E A T H E R A N D H Y D R O L O G I C A L S T A T I O N S M E T E O D A T A / H Y D R O D A T A - 2 0 0 0 C S E R I E S The type Automatic Meteorological and Hydrological Stations are
More information1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment
1995 Metric CSJ 3483-01-010 SPECIAL SPECIFICATION ITEM 6329 Multimode Video Fiber Optic Transmission Equipment 1.0 Description. This Item shall govern for the furnishing and installation of Video Fiber
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR CLOSED LOOP TRAFFIC SIGNAL SYSTEM
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR CLOSED LOOP TRAFFIC SIGNAL SYSTEM OFS:EMS 1 of 5 APPR:LWB:DBP:07-17-14 APPR FHWA: 07-30-14 a. Description. This work
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationSIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions
Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationType Approval Rules. Communications Commission of Kiribati. 12 February 2014
Type Approval Rules Communications Commission of Kiribati 12 February 2014 CCK 022014 Preliminary 1. These rules are made pursuant to Sections 61 and 62 of the Communications Act of 2012. These sections
More informationDIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS
DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS DIMETRA EXPRESS COMMUNICATIONS MADE SIMPLE DIMETRA EXPRESS MTS4 TETRA SYSTEM DIMETRA EXPRESS MTS2 TETRA SYSTEM DIMETRA EXPRESS MTS1 TETRA SYSTEM BUSINESS IS COMPLICATED
More informationAPS M1P Single-phase Micro-inverter Installation and User Manual
APS M1P Single-phase Micro-inverter Installation and User Manual Version: 1.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR
More informationROAM System Specification Guideline Division 16520
ROAM System Specification Guideline Division 16520 PART 1. GENERAL 1.1 INTRODUCTION A. The intent of this specification is to provide requirements for the ROAM system as a whole. 1.2 DESCRIPTION OF WORK
More informationInstruction also available on
TERA Radon Program EN TCR3 Central Unit Technical Specifications & Operation Manual v.2 2016 Table of Contents 1 Introduction...2 2 Description and Utilization...2 3 Scope of Delivery...4 4 Product Specification...5
More informationAPS M1P Single-phase Micro-inverter Installation and User Manual
APS M1P Single-phase Micro-inverter Installation and User Manual Version: 2.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR
More informationDESIGN PRACTICE NOTE GENERAL OCS SPECIFICATION UPDATE
Approval Amendment Record Approval Date Version Description 22/03/2017 1 Initial Issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 11 Table of Contents 1. Purpose...
More informationRF-Audience! Receiver
RF-Audience! Receiver Wireless Messaging System Product Description Issue Date: December 1997 RF-Audience! Product Description 1 Introduction, 2 Features and Benefits, 3 Flexible Configuration, 3 Enhanced
More informationClark County Fire Prevention Las Vegas Nevada
Clark County Fire Prevention Las Vegas Nevada PUBLIC SAFETY/FIRST RESPONDER RADIO AMPLIFICATION SYSTEMS SCOPE: This guideline sets forth requirements for the design, installation and testing of Public
More informationTECHNICAL SPECIFICATIONS EMERGENCY OUTDOOR VOICE & SIREN WARNING SYSTEM FOR LAUDERDALE COUNTY, MS.
TECHNICAL SPECIFICATIONS EMERGENCY OUTDOOR VOICE & SIREN WARNING SYSTEM FOR LAUDERDALE COUNTY, MS. SCOPE: The purpose of these specifications is to outline the minimum acceptable specifications for an
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationCosta Mesa California
Costa Mesa California Section 1. Title 5 of the Costa Mesa Municipal Code entitled Building and Structures, is hereby amended to add Chapter IX, entitled INBUILDING PUBLIC SAFETY RADIO SYSTEM COVERAGE
More informationRECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized
RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized 1.0 Description The Manufacturer shall provide a Rectangular Rapid
More information1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor
1995 Metric CSJ 3256-02-049 1.0 Description SPECIAL SPECIFICATION ITEM 6093 Drop/Insert Multiplexor/Demultiplexor This Item shall govern for the furnishing and installation of intelligent drop/insert multiplexor/demultiplexors
More informationKey Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring
for Sound The connects the Sound to the internet for unattended noise monitoring. It transfers the measurement data to the fully-managed NoiseScout Web Portal in real time or provides a secure access to
More informationGuidelines for the Preparation of Traffic Signal & Intelligent Transportation System Plans on Design-Build Projects August 2007
Guidelines for the Preparation of Traffic Signal & Intelligent Transportation System Plans on Design-Build Projects August 2007 INTRODUCTION Use the following Guidelines in conjunction with the Traffic
More information1 of REV:0
1 of 5 683-10573-0418 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Advance Detection Device (RADD) system for a real-time, advance vehicle-detection
More informationQuick Guide. 8 Lens. AB (Pedestrian Activated) 12 Lens. FL (24 Hr. Flashing) SZ (School Zone) 2 x 5 Lens 3 x 7 Lens. Product Series & Configurations
Quick Guide Product Series & Configurations Series Option Configuration Option Size Option 1400 Beacon 2400 Beacon AB (Pedestrian Activated) 3400 Beacon FL (24 Hr. Flashing) 8 Lens 12 Lens SZ (School Zone)
More informationDIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES
MAIN APPLICATIONS DIGITAL SWITCH MODE POWER SUPPLIES GENERAL INTRODUCTION TO QP SERIES The new generation of Digital Switch Mode Power Supplies F series QP, has been designed and is manufactured by SALICRU
More informationET2000e IRRIGATION CONTROLLER
ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION CONTROLLER SPECIFICATION HOW TO SPECIFY CONTROLLER: Step 1 Controller
More informationSECTION PANELBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section
More informationPerformance Specification for Nearside Signal and Demand Unit
traffic systems and signing TR 2511 Issue A July 2005 Performance Specification for Nearside Signal and Demand Unit Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency
More information905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use
Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at
More informationInstallation/User Manual
Installation/User Manual APS YC500-A Photovoltaic Grid-connected Inverter Version 4.1 1/15 APS America 1015 Hostmark St. Ste 104; Poulsbo, WA 98370 TEL: 206-855-5100 EMAIL: info@apsamerica.com WEB: www.apsamerica.com
More informationSuppliers' Information Note. Microconnect Distributed Antennas. Service & Interface Description
SIN 398 Issue 1.2 April 2015 Suppliers' Information Note For The BT Network Microconnect Distributed Antennas Service & Interface Description Each SIN is the copyright of British Telecommunications plc.
More informationGLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos
GLR43308 and GLR2708 Setup and programming instructions for the 8 channel Gigalink receiver Programming Videos www.elsema.com NOTES IMPORTANT WARNING AND SAFETY INSTRUCTIONS All installations and testing
More informationTECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS
TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential
More informationSPECIAL SPECIFICATION 6574 Low Power Wireless Modem
2004 Specifications CSJ 1068-04-126, etc. SPECIAL SPECIFICATION 6574 Low Power Wireless Modem 1. Description. This work shall consist of furnishing and supplying a Low Power Wireless Modem at the locations
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationRED Compliance Association REDCA TGN 01 Version 1.0 November 2018 Page 1 of 14
November 2018 Page 1 of 14 REDCA Technical Guidance Note 01 on the RED compliance requirements for a Radio Equipment often referred to as Radio Module and the Final Radio Equipment Product that integrates
More informationExternal brake resistor AX2090-BW5x
Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...
More informationTrusted Versatile FTA
PD-T8842 Trusted Product Overview The Trusted Versatile Field Termination Assembly (VFTA) T8842 is primarily designed to act as the main interface between field devices associated with the detection and
More informationFrequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
More information