ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3

Size: px
Start display at page:

Download "ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3"

Transcription

1 ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3 Electrical and ITS Engineering September 2018

2 2300 ELECTRONIC MESSAGE SIGNS 2301 PERMANENT ELECTRONIC MESSAGE SIGNS 2302 PORTABLE ELECTRONIC MESSAGE SIGNS

3 Section 2300 Electronic Message Signs Electrical and ITS Engineering June 2004 (Updated September 2018)

4 2300 ELECTRONIC MESSAGE SIGNS 2301 PERMANENT DYNAMIC MESSAGE SIGNS SCOPE MINISTRY APPROVED PRODUCTS GENERAL CHARACTERISTICS DETAILED HARDWARE STANDARDS PORTABLE DYNAMIC MESSAGE SIGNS SCOPE MINISTRY APPROVED PRODUCTS GENERAL CHARACTERISTICS DETAILED HARDWARE STANDARDS LIST OF TABLES TABLE 1: LIST OF NEMA TS APPLICABLE SECTIONS, EXCEPTIONS AND ADDITIONS... 6 TABLE 2: LIST OF NEMA TS APPLICABLE SECTIONS, EXCEPTIONS AND ADDITIONS Electrical & Signing Materials Standards Page 4

5 SCOPE 2301 PERMANENT DYNAMIC MESSAGE SIGNS.1 This specification shall apply to Fixed-Location Dynamic Message Signs (DMS)..2 DMS shall refer to Variable Message Signs (VMS) as defined in NEMA TS Fixed-Location DMS refers to a DMS mechanically attached to a non-portable support structure..4 The Fixed-Location Dynamic Message Sign, as described above, may be alternately referred to as product, fixed-location DMS, DMS or sign in this specification MINISTRY APPROVED PRODUCTS.1 Only products that are listed on the Ministry Recognized Products List are acceptable for use. Approved products can be found on the Ministry engineering website at: ok.pdf.2 See Volume 1, Chapter 102 of the Ministry Electrical and Signing Materials Standards for the product approval process. This document can be found on the Ministry engineering website at: ng/2003_material_standards/volume_1/2003_material_standards-volume_1.pdf GENERAL CHARACTERISTICS.1 This Sub-section describes general product characteristics only. Detailed hardware standards shall be as per NEMA TS with noted exceptions and additions as described in and listed in Table 1..2 The sign primary power source shall be single phase 120V AC..3 The sign display shall be line matrix, yellow LEDs as defined in the NEMA TS-4 specification (Table 5.5.1)..4 The sign shall have the capability for both local and remote control..5 The product must be compatible with the Ministry Intelligent Transportation System (ITS) operated from the Regional Traffic Management Centre in Coquitlam. The supplier shall demonstrate to Ministry Electrical and ITS Engineering personnel that the product is compatible..6 The permanent DMS shall have the capability to communicate using the NTCIP protocol.

6 PERMANENT DYNAMIC MESSAGE SIGNS DETAILED HARDWARE STANDARDS.1 The product shall conform to all applicable sections and sub-sections of the latest version of NEMA TS Hardware Standards for Dynamic Message Signs (DMS), with NTCIP Requirements, including amendments. This document may be purchased from the NEMA website at Table 1 lists the applicable sections of the NEMA standard noted above, as well as any exceptions or additions. Sections without exceptions or additions shall apply in full. Table 1: List of NEMA TS Applicable Sections, Exceptions and Additions 1 All No exceptions or additions. 2 All No exceptions or additions Does not apply. Walk in enclosures are not permitted Sign shall be front access. Add: The weight of the entire sign assembly, excluding the backboard, shall not exceed 200kg Does not apply Does not apply Does not apply. 3.3 Does not apply Reference to National Electrical Code shall be changed to Canadian Electrical Code Reference to National Electrical Code shall be changed to Canadian Electrical Code Does not apply Does not apply. All Only sub-sections referring to Light Emitting Technology shall apply. Light Emitting Technology shall be strictly limited to Light Emitting Diode (LED) technology. Add: The sign shall utilize yellow (as defined in table 5.5.1) LED s exclusively for message display (LED hybrid technology is not permitted). The viewing angle or cone of vision for each pixel shall be a minimum of Type Class e as defined in Table 5.3 +/- 15 degrees horizontal and -10 degrees vertical. Add: The sign display shall be line-matrix and shall have the capability to 5.6 display two lines of 20 characters, each character being composed of 5 X 7 pixels and being 450mm (18 inches) in height. Pixels shall be composed of a minimum of four LEDs. 6.1 Only Sub-sections referring to Line Matrix Signs shall apply. Add: Each line shall be composed of a minimum of 7 modules (minimum per sign). 6.2 Does not apply. 6.3 No exceptions or additions. Electrical & Signing Materials Standards Page 6

7 PERMANENT DYNAMIC MESSAGE SIGNS Does not apply. 6.5 Does not apply Add: DMS Cabinet shall comply fully with all requirements of Ministry Material Standards Volume 1, Chapter Reference to UL shall be replaced with ULC or CSA Does not apply Does not apply Does not apply Add: The sign shall have the capability to communicate over the following media: 1. Direct serial. 2. Serial using fixed subscriber line, dial-up cellular or satellite telephone line. 3. Internet Protocol (IP). The Vendor shall supply one modem, of the applicable type, plus interconnect cabling per sign. For wireless applications, the Vendor shall supply one Ministry-approved modem, plus antenna, power supply and interconnect cabling per sign. The Vendor is ultimately responsible to ensure that the supplied modem is fully compatible with the specified protocol application Add: The Vendor shall supply a list of supported protocols and object definitions Add: Local messaging shall typically be used only for maintenance purposes. Add: Unless otherwise specified in the Special Provisions, local messaging shall typically be used only for maintenance purposes. Normal operation shall be to download an immediate message from the control center. Add: Each NTCIP Component covered by this specification shall implement the most recent version of the standard that is at the stage of Recommended or higher as of April 2004, including approved or recommended amendments. It is the responsibility of the vendor to monitor NTCIP activities to discover any more recent documents. The vendor shall supply a list of supported protocols and object definitions. Add: The sign shall support both Portable Maintenance Computer and local control panel interfaces. The local control panel interface shall be able to display local library 8.11 messages without the use of a computer or hand-held programming device. The vendor shall supply software necessary to facilitate local control of the sign with a Portable Maintenance Computer Does not apply Does not apply. Electrical & Signing Materials Standards Page 7

8 PERMANENT DYNAMIC MESSAGE SIGNS Add: If required by inclusion in the Special Provisions, backup power may be used to maintain operation of the sign during power line failures. If so, the sign shall continue to display the current message until line power is restored or until the backup power supply is exhausted, which ever occurs first. The sign controller shall provide alarm indications to the CC for both 9 line power failure and backup power failure. The sign display shall be blanked at a backup voltage level sufficient to maintain sign controller and communications operation for a further 90 minutes Add: The Special Provisions shall list the required sign operation during communication link failures Reference to NEC shall be changed to CEC. Add: Auxiliary equipment, such has heating, ventilation and GFCI receptacle shall be fed by circuits separate from the sign controller or display. Failure of an auxiliary circuit shall not affect sign operation. Backup power shall be provided in the form of an Uninterruptible Power Supply (UPS) capable of powering the sign and associated electronics for up to 90 minutes during a power failure The vendor shall engage a third-party source to perform the conformance testing Add: If the vendor has never previously supplied a permanent DMS product to the Ministry, the vendor shall supply a sample unit for testing and evaluation purposes. The sample unit shall consist of the following: a module arrangement capable of displaying a minimum of three characters (minimum of two modules required); controller unit; hand held programming unit; vendor s sign control software package; and all mounting rails, connecting components, and other materials and equipment required to provide a functional sample sign. The sample unit shall be returned to the vendor upon completion of the evaluation Add: For each section, the Vendor shall qualify the level of compliance as follows: 1. Fully complies. 2. Complies with exceptions (vendor shall describe any exceptions). 3. Does not comply. The Ministry reserves the right to accept or reject any product based on its level of compliance. False declarations of compliance are grounds for rejection of any product Add: The Vendor shall supply System Diagrams Add: The Vendor shall supply Wiring Diagrams Add: The Vendor shall supply Cabinet Shop drawings to the Ministry for approval prior to fabrication. The Vendor shall supply sign mounting detail drawings, in AutoCAD.dwg format, signed by a registered Structural Engineer, prior to fabrication. An example of a suitable format is shown in Ministry Material Standard drawing MSxxxxxxx Replace with: The Vendor shall supply a written declaration of compliance as described in 11.4 above. Electrical & Signing Materials Standards Page 8

9 PERMANENT DYNAMIC MESSAGE SIGNS Replace with: The Vendor shall supply the MIB information for the signs Add: The Vendor shall supply Configuration Information Add: Test results are not required unless requested in writing by the Ministry representative. 12 Add: The maximum paper size for schematics, layouts, etc. is 11 x17 and 12.3 all such documentation shall be single-sided Add: A service manual shall be supplied with each sign Add: A trouble shooting manual shall be supplied with each sign Add: An operators manual shall be supplied with each sign. Electrical & Signing Materials Standards Page 9

10 SCOPE 2302 PORTABLE DYNAMIC MESSAGE SIGNS.1 This specification shall apply to portable Dynamic Message Signs (DMS)..2 DMS shall refer to Variable Message Signs (VMS) as defined in NEMA TS Portable DMS shall refer to a DMS that can be moved easily and used in applications such as construction sites, special events, or as a temporary advisory sign. The portable DMS shall be designed with electrical and mechanical characteristics that support such mobility and autonomous operation..4 The portable Dynamic Message Sign, as described above, may be alternately referred to as product, portable DMS, DMS or sign in this specification MINISTRY APPROVED PRODUCTS.1 Only products that are listed on the Ministry Recognized Products List are acceptable for use. Approved products can be found on the Ministry engineering website at: ok.pdf.2 See Volume 1, Chapter 102 of the Ministry Electrical and Signing Materials Standards for the product approval process. This document can be found on the Ministry engineering website at: ng/2003_material_standards/volume_1/2003_material_standards-volume_1.pdf

11 PORTABLE DYNAMIC MESSAGE SIGNS GENERAL CHARACTERISTICS.1 This Sub-section describes general product characteristics only. Detailed hardware standards shall be as per NEMA TS with noted exceptions and additions as described in and listed in Table 2..2 The sign shall be trailer mounted and fully transportable..3 The sign primary power source shall be solar..4 The sign display shall be full matrix, yellow/orange LED..5 The sign shall have the capability for both local and remote control..6 The product must be compatible with the Ministry Intelligent Transportation System (ITS) operated from the Regional Traffic Management Centre in Coquitlam. The supplier shall demonstrate to Ministry Electrical and ITS Engineering personnel that the product is compatible..7 The portable DMS shall have the capability to communicate using the NTCIP protocol DETAILED HARDWARE STANDARDS.1 The product shall conform to all applicable sections and sub-sections of the latest version of NEMA TS Hardware Standards for Dynamic Message Signs (DMS), with NTCIP Requirements, including amendments. This document may be purchased from the NEMA website at Table 2 lists the applicable sections of the NEMA standard noted above, as well as any exceptions or additions. Sections without exceptions or additions shall apply in full. Table 2: List of NEMA TS Applicable Sections, Exceptions and Additions. 1 All No exceptions or additions. 2 All No exceptions or additions. 3.1 No exceptions or additions. 3.2 Does not apply. 3.3 Add: The axle shall be torsion-flex type construction. The tires shall be 381mm (15 ) Load Range C or better Add: The leveling devices shall be permanently mounted to the trailer frame Add: The hitch shall be 51mm (2 ) ball type. The tongue shall be removable using a quick-disconnect method New: The trailer shall be equipped with suitably rated surge or electric brakes. Electrical & Signing Materials Standards Page 11

12 PORTABLE DYNAMIC MESSAGE SIGNS Add: All metal surfaces shall be primed and powder coated Add: Battery enclosures shall be rust-proof Add: The sign shall use solar power as the primary power source. The solar array shall be able to produce a minimum of 420 Watts and shall tilt and rotate independently of the sign display enclosure. Add: The sign shall have a battery bank with a total minimum capacity of A-Hr. at 12 VDC The battery charger or inverter/charger, as applicable, for normal solar charging or external backup charging shall be rated between 50 and 70A at 12 VDC. Add: The sign shall have the capability to charge the batteries from an alternate backup power supply, as required to augment the capability of the solar array during periods of reduced charging time, including external 120 Vac power supply and/or backup power generator. 4 All No exceptions or additions. All Only Sub-sections referring to Light Emitting Technology shall apply Add: The sign shall utilize yellow (as defined in table 5.5.1) LED s exclusively for message display (LED hybrid technology is not permitted). The viewing angle or cone of vision for each pixel shall be a minimum of Type Class e as defined in Table 5.3 +/- 15 degrees horizontal and -10 degrees vertical. 5.6 Add: The sign display shall be full-matrix and shall have the capability to display three lines of eight characters, each character being composed of 5 x 7 pixels and being 450mm (18 inches) in height. 6.1 Only Sub-sections referring to Line Matrix Signs shall apply. 6.2 Does not apply No exceptions or additions. 6.4 Does not apply. 6.5 Does not apply. 7 All No exceptions or additions Does not apply Does not apply Does not apply Add: The sign shall have the capability to communicate over the following media: 4. Dial-up cellular or satellite telephone line. 5. CDMA 1X protocol cellular telephone (IP-based). The Vendor shall supply one modem, plus antenna (if required), power supply and interconnect cabling per sign. For 1X protocol applications, the Vendor shall supply one Sierra Wireless MP 555 GPS modem, or Ministry-approved equivalent, plus antenna, power supply and interconnect cabling per sign. The Vendor is ultimately responsible to ensure that the supplied modem is fully compatible with the specified protocol application. Electrical & Signing Materials Standards Page 12

13 PORTABLE DYNAMIC MESSAGE SIGNS Add: The Vendor shall supply a list of supported protocols and object definitions Add: The sign shall have the capability for both local and remote control and both Centralized and Local Messaging shall be supported Add: The local message library shall be able to store a minimum of 16 user-defined messages Add: Each NTCIP Component covered by this specification shall implement the most recent version of the standard that is at the stage of Recommended or higher as of April 2004, including approved or recommended amendments. It is the ultimate responsibility of the vendor to monitor NTCIP activities to discover any more recent documents. The vendor shall supply a list of supported protocols and object definitions Add: The sign shall support both Portable Maintenance Computer and local control panel interfaces. The local control panel interface shall be able to display local library messages without the use of a computer or hand-held programming device. The vendor shall supply software necessary to facilitate local control of the sign with a Portable Maintenance Computer Does not apply Does not apply. 10 All No exceptions or additions Add: The Vendor shall supply a written declaration indicating the level of compliance of his or her product with each of the applicable sections of this specification. For each section, the Vendor shall qualify the level of compliance as follows: 4. Fully Complies. 5. Complies with Exceptions (Vendor shall describe any exceptions). 6. Does Not Comply. The Ministry reserves the right to accept or reject any product based on its level of compliance. False declarations of compliance are grounds for rejection of any product Add: The Vendor shall supply System Diagrams Add: The Vendor shall supply Wiring Diagrams Replace with: The Vendor shall supply a written declaration of compliance as described in 11.4 above Replace with: The Vendor shall supply the MIB information for the signs Add: The Vendor shall supply Configuration Information Add: Test results are not required unless requested in writing by the Ministry representative Add: The maximum paper size for schematics, layouts, etc. is 11 x17 and all such documentation shall be single-sided. Electrical & Signing Materials Standards Page 13

14 PORTABLE DYNAMIC MESSAGE SIGNS Add: A service manual shall be supplied with each sign Add: A trouble shooting manual shall be supplied with each sign Add: An operator manual shall be supplied with each sign. Electrical & Signing Materials Standards Page 14

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV# RCF 3.4 Portable Traffic Signal - Technical Specifications Signal Controller Hardware Each signal controller shall be capable of providing the following feedback information to the user: Audible low battery

More information

Variable Message Sign Trailers

Variable Message Sign Trailers Variable Message Sign Trailers Frequently Asked Questions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. What standard are the VMS

More information

HT1100 Satellite Modem User Guide

HT1100 Satellite Modem User Guide HT1100 Satellite Modem User Guide 1039650-0001 Revision C October 11, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems,

More information

APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID

APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 BIDDER INSTRUCTIONS: All Bidder pricing must be based on the Sample Product provided in Appendix H Mandatory Requirements. Any category in Appendix H that

More information

SECTION GPS WIRELESS CLOCK SYSTEMS

SECTION GPS WIRELESS CLOCK SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. G.P.S. Receiver B. Primary Transmitter C. Satellite Transmitter D. Analog Clocks E. Digital Clocks 1.2 REGULATORY REQUIREMENTS SECTION 27 53 13 GPS WIRELESS CLOCK

More information

Voicestar T100 Series Specifications for Solar Powered Highway Advisory Radio

Voicestar T100 Series Specifications for Solar Powered Highway Advisory Radio AMERICAN SIGNAL COMPANY 2755 Bankers Industrial Drive Atlanta, GA 30360 Phone: 770-448-6650 Fax: 770-448-8970 Voicestar T100 Series Specifications for Solar Powered Highway Advisory Radio 032110 1.0 SCOPE

More information

CONSTRUCTION SPECIFICATION FOR PORTABLE TEMPORARY TRAFFIC SIGNALS

CONSTRUCTION SPECIFICATION FOR PORTABLE TEMPORARY TRAFFIC SIGNALS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 708 November 2016 CONSTRUCTION SPECIFICATION FOR PORTABLE TEMPORARY TRAFFIC SIGNALS TABLE OF CONTENTS 708.01 SCOPE 708.02 REFERENCES 708.03 DEFINITIONS

More information

SPECIAL PROVISION Description of Project, Scope of Contract and Sequence of Work

SPECIAL PROVISION Description of Project, Scope of Contract and Sequence of Work 2004 Specifications CSJ 0110-04-166 SPECIAL PROVISION 000--363 Description of Project, Scope of Contract and Sequence of Work 1. General. The work to be performed on this project consists of furnishing,

More information

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem 1993 Specifications CSJ s 0902-48-442 & 0902-48-432 SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem 1. General. This Item shall govern for the furnishing and installation of Spread Spectrum Wireless

More information

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem 1993 Specifications CSJ 2266-02-095 SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem

More information

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters Section [26 35 26][16280] Active Harmonic Filters (Low Voltage) Part 1 General 1.1 Summary A. Scope: Provide design and engineering, labor,

More information

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem (OTR) in

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER OPR:DJA 1 of 5 C&T:APPR:JAR:DBP:09-01-11 FHWA:APPR:09-01-11 a. Description. This work consists

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS METEODATA/HYDRODATA-3000C SERIES Brochure nº 9722.0044 GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel. +34 91 450 51 18 Fax +34 91 459 46

More information

M-0418 REV:0

M-0418 REV:0 1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that

More information

EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION

EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION CITY OF LACEY Community & Economic Development Department 420 College Street SE Lacey, WA 98503 (360) 491-5642 CASH OR CHECK ONLY PLEASE EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION FOR INSTALLATION/MODIFICATION

More information

SECTION CABLE TRAYS

SECTION CABLE TRAYS SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General Section 16621A - AUTOMATIC TRANSFER SWITCH Part 1 General 1.01 One 600 Amp, 3 Phase, 480 Volt Automatic Transfer Switch (ATS) shall be provided with gasketed enclosure. The ATS shall consist of an inherently

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016 STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE January 15, 2016 919.01 Traffic Signal Cabinet and Controller Unit General Requirements 919.02 Approved

More information

ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO

ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO ACC 1 Flow Sensor (HFS): Reports actual flow Put an end to flow emergencies forever. To bring real-time flow sensing to the ACC,

More information

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide JOINT STOCK COMPANY MULTICHANNEL RECEIVER RI-4010M (version RM1-60619) User guide Safety requirements Before using the multichannel receiver RI-4010M read this user guide and follows safety requirements!

More information

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System Architectural/Engineering Specification for a Microwave Perimeter Intrusion Detection System µltrawave Disclaimer Senstar, and the Senstar logo are registered trademarks, and µltrawave, Silver Network

More information

Brochure nº

Brochure nº A U T O M A T I C W E A T H E R A N D H Y D R O L O G I C A L S T A T I O N S M E T E O D ATA / H Y D R O D ATA-3 0 0 0 C S E R I E S GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel.

More information

ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013

ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013 ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

City of Irvine California Signal Booster Ordinance

City of Irvine California Signal Booster Ordinance City of Irvine California Signal Booster Ordinance CHAPTER 6. PUBLIC SAFETY RADIO SYSTEM COVERAGE Sec. 5-9-601. Intent and purpose. The intent of the chapter is to provide a regulatory framework for the

More information

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS 510.1 Emergency responder radio coverage in new buildings. Approved radio coverage for emergency responders shall be provided within all buildings meeting any one of the following conditions: 1. There

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Wireless Gas Detection System

Wireless Gas Detection System Wireless Gas Detection System Sensidyne SensCast Brochure Rev.A Wireless Gas Detection System The Sensidyne SensCast Wireless Monitoring System consists of 1-32 battery-powered SensCast Transmitters and

More information

Connecting Mains Electrical Power

Connecting Mains Electrical Power Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE International Telecommunication Union ITU-T K.49 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2005) SERIES K: PROTECTION AGAINST INTERFERENCE Test requirements and performance criteria for voice

More information

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web: Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Technical Reference Capstone MicroTurbine Electrical Installation 410009 Rev F (October 2013) Page 1 of 31 Capstone Turbine Corporation

More information

MOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION

MOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION MOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION P a g e 1 North Lawrence Community Schools October 1, 2012 P a g e 2 Table of Contents TABLE OF CONTENTS... 2 GENERAL SYSTEM OVERVIEW... 3 REQUIRED

More information

PAPI Infrared Operation Overview

PAPI Infrared Operation Overview PAPI Infrared Operation Overview USER MANUAL SUPPLEMENT Technical Support: Email: customerservice@carmanah.com Toll Free: 1.877.722.8877 (US & Canada) Worldwide: 1.250.380.0052 Fax: 1.250.380.0062 Web:

More information

2.1. Description: A bank of batteries forming a 12 VDC system shall power the unit.

2.1. Description: A bank of batteries forming a 12 VDC system shall power the unit. AMERICAN SIGNAL COMPANY 2755 Bankers Industrial Drive Atlanta, GA 30360 Phone: 770-448-6650 Fax: 770-448-8970 T-25 Portable Solar Charged Mast Trailer Specifications For use with AMSIG Changeable Message

More information

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 1. Description. Furnish and install spread spectrum radio system. 2. Materials. Supply complete manufacturer specifications

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor 1993 Specifications CSJ 0008-12-071 SPECIAL SPECIFICATION ITEM 6550 Drop/Insert Multiplexor/Demultiplexor 1.0 Description. This Item shall govern for the furnishing and installation of intelligent drop/insert

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

Update of GPS systems technical specifications and challenges

Update of GPS systems technical specifications and challenges Update of GPS systems technical specifications and challenges GPS Communication Power Bjorn Johns September 7, 2005 Polar Technology Workshop Washington, DC GPS receivers State-of-the-art in 2005: Power:

More information

wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution

wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution smart grid n automated meter infrastructure n distribution Ventev s product solutions

More information

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit 1993 Specifications SPECIAL SPECIFICATION 1201 12 Inch LED Traffic Signal Lamp Unit 1. Description. This specification describes the minimum acceptable design and performance requirements for a twelve

More information

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,

More information

AMU-214 Auxiliary Monitor Unit Operations Manual

AMU-214 Auxiliary Monitor Unit Operations Manual AMU-214 Auxiliary Monitor Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE AMU-214 SERIES ITS CABINET AUXILIARY MONITOR UNIT. REVISION: SEPTEMBER 2008 pn 888-0214-001 THE AMU-214 SERIES AUXILIARY

More information

S.W.A.T. World Leader in supplying S.W.A.T Equipment &Training SNIPER MANAGEMENT SYSTEMS

S.W.A.T.  World Leader in supplying S.W.A.T Equipment &Training SNIPER MANAGEMENT SYSTEMS SNIPER MANAGEMENT SYSTEMS The SNIPER MANAGEMENT SYSTEM is a real time integrated system video, audio and data communications which allows the Commanding officer in charge of the operation to be placed

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

Trusted Power Distribution Unit MCB 24 Vdc

Trusted Power Distribution Unit MCB 24 Vdc PD-T8292 Trusted Trusted Power Distribution Unit MCB 24 Vdc Product Overview The dual 5-channel Trusted Power Distribution Unit Miniature Circuit Breaker (MCB) 24 V is designed for N+1 or 100 % redundant

More information

CP /240-MC4 User Manual

CP /240-MC4 User Manual CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...

More information

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1995 Metric CSJ's 1047-03-056 & 0008-08-066 SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Tel: Fax:

Tel: Fax: Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie

More information

CLARK COUNTY FIRE CODE AMENDMENTS

CLARK COUNTY FIRE CODE AMENDMENTS CLARK COUNTY FIRE CODE AMENDMENTS SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM is amended to read as follows: SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM 510.1 Emergency responder radio

More information

Portable Signals: INDOT Design Guidance and Specifications

Portable Signals: INDOT Design Guidance and Specifications : INDOT Design Guidance and Specifications Joe Bruno, P.E. Traffic Administration, INDOT March 7, 2017 Presentation Overview Background Design Manual 83-5.0 and Design Memo 16-06 Cost and Pay Item Info

More information

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read: Sunnyvale 2013 Fire Code Section 510 16.52.510. Emergency responder radio coverage. (a) Emergency responder radio coverage in new buildings. California Fire Code Section 510.1 is hereby amended to read:

More information

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic

More information

Exhibit 8 User Manual. 8 Product Functional Requirements (User Manual)

Exhibit 8 User Manual. 8 Product Functional Requirements (User Manual) Ground Systems Division User Manual Motorola Customer Premise Equipment (CPE) Model No. LT 20M-00 8 Product Functional Requirements (User Manual) 8.1 Scope The requirements described herein are functional

More information

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor 1993 Specifications CSJ 0177-11-131 SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor 1. Description. This Item shall govern for for the furnishing and installation of intelligent drop/insert

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring

More information

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data 2004 Specifications CSJ 0617-01-169 SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data 1. Description. This Item shall govern for the furnishing and installation of Video optical transceiver

More information

CHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE INTENT AND PURPOSE DEFINITIONS USE AND OCCUPANCY EXEMPTIONS.

CHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE INTENT AND PURPOSE DEFINITIONS USE AND OCCUPANCY EXEMPTIONS. CHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE 8950 - INTENT AND PURPOSE The intent of the chapter is to provide a regulatory framework for the purpose of providing effective 800 MHz Countywide Coordinated

More information

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax A U T O M A T I C W E A T H E R A N D H Y D R O L O G I C A L S T A T I O N S M E T E O D A T A / H Y D R O D A T A - 2 0 0 0 C S E R I E S The type Automatic Meteorological and Hydrological Stations are

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment 1995 Metric CSJ 3483-01-010 SPECIAL SPECIFICATION ITEM 6329 Multimode Video Fiber Optic Transmission Equipment 1.0 Description. This Item shall govern for the furnishing and installation of Video Fiber

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR CLOSED LOOP TRAFFIC SIGNAL SYSTEM

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR CLOSED LOOP TRAFFIC SIGNAL SYSTEM MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR CLOSED LOOP TRAFFIC SIGNAL SYSTEM OFS:EMS 1 of 5 APPR:LWB:DBP:07-17-14 APPR FHWA: 07-30-14 a. Description. This work

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Type Approval Rules. Communications Commission of Kiribati. 12 February 2014

Type Approval Rules. Communications Commission of Kiribati. 12 February 2014 Type Approval Rules Communications Commission of Kiribati 12 February 2014 CCK 022014 Preliminary 1. These rules are made pursuant to Sections 61 and 62 of the Communications Act of 2012. These sections

More information

DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS

DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS DIMETRA EXPRESS COMMUNICATIONS MADE SIMPLE DIMETRA EXPRESS MTS4 TETRA SYSTEM DIMETRA EXPRESS MTS2 TETRA SYSTEM DIMETRA EXPRESS MTS1 TETRA SYSTEM BUSINESS IS COMPLICATED

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 1.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

ROAM System Specification Guideline Division 16520

ROAM System Specification Guideline Division 16520 ROAM System Specification Guideline Division 16520 PART 1. GENERAL 1.1 INTRODUCTION A. The intent of this specification is to provide requirements for the ROAM system as a whole. 1.2 DESCRIPTION OF WORK

More information

Instruction also available on

Instruction also available on TERA Radon Program EN TCR3 Central Unit Technical Specifications & Operation Manual v.2 2016 Table of Contents 1 Introduction...2 2 Description and Utilization...2 3 Scope of Delivery...4 4 Product Specification...5

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 2.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

DESIGN PRACTICE NOTE GENERAL OCS SPECIFICATION UPDATE

DESIGN PRACTICE NOTE GENERAL OCS SPECIFICATION UPDATE Approval Amendment Record Approval Date Version Description 22/03/2017 1 Initial Issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 11 Table of Contents 1. Purpose...

More information

RF-Audience! Receiver

RF-Audience! Receiver RF-Audience! Receiver Wireless Messaging System Product Description Issue Date: December 1997 RF-Audience! Product Description 1 Introduction, 2 Features and Benefits, 3 Flexible Configuration, 3 Enhanced

More information

Clark County Fire Prevention Las Vegas Nevada

Clark County Fire Prevention Las Vegas Nevada Clark County Fire Prevention Las Vegas Nevada PUBLIC SAFETY/FIRST RESPONDER RADIO AMPLIFICATION SYSTEMS SCOPE: This guideline sets forth requirements for the design, installation and testing of Public

More information

TECHNICAL SPECIFICATIONS EMERGENCY OUTDOOR VOICE & SIREN WARNING SYSTEM FOR LAUDERDALE COUNTY, MS.

TECHNICAL SPECIFICATIONS EMERGENCY OUTDOOR VOICE & SIREN WARNING SYSTEM FOR LAUDERDALE COUNTY, MS. TECHNICAL SPECIFICATIONS EMERGENCY OUTDOOR VOICE & SIREN WARNING SYSTEM FOR LAUDERDALE COUNTY, MS. SCOPE: The purpose of these specifications is to outline the minimum acceptable specifications for an

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Costa Mesa California

Costa Mesa California Costa Mesa California Section 1. Title 5 of the Costa Mesa Municipal Code entitled Building and Structures, is hereby amended to add Chapter IX, entitled INBUILDING PUBLIC SAFETY RADIO SYSTEM COVERAGE

More information

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized 1.0 Description The Manufacturer shall provide a Rectangular Rapid

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor 1995 Metric CSJ 3256-02-049 1.0 Description SPECIAL SPECIFICATION ITEM 6093 Drop/Insert Multiplexor/Demultiplexor This Item shall govern for the furnishing and installation of intelligent drop/insert multiplexor/demultiplexors

More information

Key Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring

Key Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring for Sound The connects the Sound to the internet for unattended noise monitoring. It transfers the measurement data to the fully-managed NoiseScout Web Portal in real time or provides a secure access to

More information

Guidelines for the Preparation of Traffic Signal & Intelligent Transportation System Plans on Design-Build Projects August 2007

Guidelines for the Preparation of Traffic Signal & Intelligent Transportation System Plans on Design-Build Projects August 2007 Guidelines for the Preparation of Traffic Signal & Intelligent Transportation System Plans on Design-Build Projects August 2007 INTRODUCTION Use the following Guidelines in conjunction with the Traffic

More information

1 of REV:0

1 of REV:0 1 of 5 683-10573-0418 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Advance Detection Device (RADD) system for a real-time, advance vehicle-detection

More information

Quick Guide. 8 Lens. AB (Pedestrian Activated) 12 Lens. FL (24 Hr. Flashing) SZ (School Zone) 2 x 5 Lens 3 x 7 Lens. Product Series & Configurations

Quick Guide. 8 Lens. AB (Pedestrian Activated) 12 Lens. FL (24 Hr. Flashing) SZ (School Zone) 2 x 5 Lens 3 x 7 Lens. Product Series & Configurations Quick Guide Product Series & Configurations Series Option Configuration Option Size Option 1400 Beacon 2400 Beacon AB (Pedestrian Activated) 3400 Beacon FL (24 Hr. Flashing) 8 Lens 12 Lens SZ (School Zone)

More information

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES MAIN APPLICATIONS DIGITAL SWITCH MODE POWER SUPPLIES GENERAL INTRODUCTION TO QP SERIES The new generation of Digital Switch Mode Power Supplies F series QP, has been designed and is manufactured by SALICRU

More information

ET2000e IRRIGATION CONTROLLER

ET2000e IRRIGATION CONTROLLER ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION CONTROLLER SPECIFICATION HOW TO SPECIFY CONTROLLER: Step 1 Controller

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Performance Specification for Nearside Signal and Demand Unit

Performance Specification for Nearside Signal and Demand Unit traffic systems and signing TR 2511 Issue A July 2005 Performance Specification for Nearside Signal and Demand Unit Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

Installation/User Manual

Installation/User Manual Installation/User Manual APS YC500-A Photovoltaic Grid-connected Inverter Version 4.1 1/15 APS America 1015 Hostmark St. Ste 104; Poulsbo, WA 98370 TEL: 206-855-5100 EMAIL: info@apsamerica.com WEB: www.apsamerica.com

More information

Suppliers' Information Note. Microconnect Distributed Antennas. Service & Interface Description

Suppliers' Information Note. Microconnect Distributed Antennas. Service & Interface Description SIN 398 Issue 1.2 April 2015 Suppliers' Information Note For The BT Network Microconnect Distributed Antennas Service & Interface Description Each SIN is the copyright of British Telecommunications plc.

More information

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver.   Programming Videos GLR43308 and GLR2708 Setup and programming instructions for the 8 channel Gigalink receiver Programming Videos www.elsema.com NOTES IMPORTANT WARNING AND SAFETY INSTRUCTIONS All installations and testing

More information

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential

More information

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem 2004 Specifications CSJ 1068-04-126, etc. SPECIAL SPECIFICATION 6574 Low Power Wireless Modem 1. Description. This work shall consist of furnishing and supplying a Low Power Wireless Modem at the locations

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair

More information

RED Compliance Association REDCA TGN 01 Version 1.0 November 2018 Page 1 of 14

RED Compliance Association REDCA TGN 01 Version 1.0 November 2018 Page 1 of 14 November 2018 Page 1 of 14 REDCA Technical Guidance Note 01 on the RED compliance requirements for a Radio Equipment often referred to as Radio Module and the Final Radio Equipment Product that integrates

More information

External brake resistor AX2090-BW5x

External brake resistor AX2090-BW5x Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...

More information

Trusted Versatile FTA

Trusted Versatile FTA PD-T8842 Trusted Product Overview The Trusted Versatile Field Termination Assembly (VFTA) T8842 is primarily designed to act as the main interface between field devices associated with the detection and

More information

Frequency selective monitoring and logging of environmental electromagnetic fields

Frequency selective monitoring and logging of environmental electromagnetic fields FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser

More information