Sigfox Verified TM. Test Procedure RSA-SDR-DONGLE for RC1-UDL-ENC. Version April 24, Public Use
|
|
- Emory Warren
- 5 years ago
- Views:
Transcription
1 Version April 24, 2018 Sigfox Verified TM Test Procedure RSA-SDR-DONGLE for RC1-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This document is the property of Sigfox. It shall not be copied and / or disclosed to third parties, in any form without Sigfox written permission.
2 IMPORTANT NOTICE The device proposed in Sigfox Certification has to be representative of the ones present in the field. To succeed in your Sigfox certification, you need to : Read carefully the Radio_Signal_Analyzer User Guide (available on ). Have a Sigfox Checklist (available on ) properly filled in (all information in the checklist will be used all tests long). 1
3 Contents 1 Introduction Scope Acronyms and abbreviations Radio_Signal_Analyzer User guide Verdict Type Checklist Information Sigfox Verified Tests Test Setup Tests Execution Execute with Test Mode : TX-BPSK a Nominal Voltage Configuration b Minimum Voltage Configuration c Maximum Voltage Configuration Execute with Test Mode : TX-PROTOCOL a Protocol b Uplink Encrypted Payload c NVM d Public Key e Frequencies Distribution Execute with Test Mode : RX-PROTOCOL a Downlink b Downlink Encrypted c Downlink Window : Start of Listening d Downlink Window : End of Listening Execute with Test Mode : RX-GFSK Execute with Test Mode : RX-SENSITIVITY Execute with Test Mode : TX-SYNTH Results 14 2
4 1 Introduction This document describes the test procedure compliant with the Sigfox Ultra Narrow Band Modem Test Plan ( PTP- UNB-MODEM ). 1.1 Scope This document is delivered to Device Makers to help them execute Sigfox tests before the official Certification. 1.2 Acronyms and abbreviations - 2GFSK: 2-Level Gaussian Frequency Shift Keying - ACK: Acknowledgement - AES: Advanced Encryption Standard - Att: Attenuator - CAB: Client Application Board - CBC: Cipher Block Chaining - CS: Carrier Sense - Cold Test: Test executed in initial condition (wait till the DUT come back to the initial system between two tests) - DBPSK: Differential Binary Phase-Shift Keying - DUT: Device Under Test - ENC: Encrypted - Fd: DUT Frequency - Fe: Equipment Frequency - Legacy Uplink: initial payload format of Sigfox Uplink without encryption - LBT: Listen Before Talk - NVM: Non Volatile Memory - OOB: Out Of Band - PAC: Porting Authorization Code - PER: Packet Error Rate - PMR: Private Mobile Radio - RC: Radio Configuration - RF: Radio Frequency - RSA: Radio_Signal_Analyzer - RSSI_dut: DUT RSSI - RSSI_eq: Equipment RSSI - SMIQ: Vector Signal Generator - SOC: System On Chip - Sigfox Message: Three frames with payload A3B - UNB_MODEM: Ultra Narrow Band MODEM - UNBT: Ultra Narrow Band Transceiver 3
5 1.3 Radio Signal Analyzer User guide Before starting test, read carefully the Radio_Signal_Analyzer User guide (available on ), it will be easier to use Radio_Signal_Analyzer and to find all things after that Verdict Type EVALUATION All requirements are manual verdict and have to be updated by the operator. Check each "Covered requirement" table to know the manual verdict and the "Manual Verdict" explanation to know if this verdict is "FAILED" or "PASSED". TOOL-ANALYSIS All requirements are automatic verdict and will be updated automatically by Radio_Signal_Analyzer. MEASUREMENT All measurement are automatic and will be updated automatically by RSA Checklist Information All information from the checklist have to be filled in properly before starting test. Radio_Signal_Analyzer should be configured according to this checklist (RCx, modem type, ID/KEY values,...). Some checklist information will be needed all test long. 4
6 2 Sigfox Verified Tests All tests below are described to help to validate some requirements for the Sigfox Verified TM during the development, but it s not a certification. certification. It could help 2.1 Test Setup Test Setup : Connect DUT to SDR-DONGLE (with 40dB attenuator) Launch Radio_Signal_Analyzer Populate the "device Configuration" window "Device STATIC Configuration" : choose the Modem Type, Radio Configuration, Payload Encryption This configuration should not be modified after starting the certification. "Device DYNAMIC Configuration" : Configure your ID/KEY Select "SDR DONGLE" in the "Tester" part Click "Open" Click "Start" Before starting your tests, fill in all DUT information in "Info / Prereq / Equipment / Verdicts" window ("Information" subwindow) Before starting your tests, fill in all equipment information according to your setup in "Info / Prereq / Equipment / Verdicts" window ("Equipment" subwindow), or load your equipment information file (if already saved) 2.2 Tests Execution Execute with Test Mode : TX-BPSK TEST CONDITION Cold tests have to be done to validate all RF requirements, the goal is to validate the device in worst condition (before established system) a Nominal Voltage Configuration 5
7 Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Nominal Voltage" Click "Raw IQ File" to start the record in the "Device" part Run the Sigfox Test Mode TX-BPSK (with config 3, if Sigfox library older than V2.2.0) with your DUT Click "Raw IQ File" again to stop the record Check the record size (value should be different from 0 MB) Manual Verdict : I/Q Wave record : This test is PASSED only if the Operator has recorded properly the TX-BPSK in nominal voltage. Static Frequency Tolerance : This test is PASSED only if the (Static Frequency accuracy given by RSA (or frequency tolerance if TCXO without calibration) + aging (on 5 years) + max temperature tolerance) < 20 ppm. Add all values in the "comment" line. DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelope" window). The "Narrow Band Power Distribution" requirement cannot be validated due to equipment limitations. PRS-UNB-MODEM-13 Static Frequency Tolerance EVALUATION PRS-UNB-MODEM-20 DBPSK Modulation envelop EVALUATION PRS-UNB-MODEM-21 Phase Measurement TOOL-ANALYSIS PRS-UNB-MODEM-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-30 TX Max Symbol duration TOOL-ANALYSIS PRS-UNB-MODEM-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-UNB-MODEM-40 Power Spectral Density TOOL-ANALYSIS PRS-UNB-MODEM-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-UNB-MODEM-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-110 Modulated Conducted Output Power MEASUREMENT PRS-UNB-MODEM-130 I/Q Wave record EVALUATION b Minimum Voltage Configuration Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Minimum Voltage" Power up the DUT in Minimum Voltage Run the Sigfox Test Mode TX-BPSK (with config 3, if Sigfox library older than V2.2.0) with your DUT 6
8 Manual Verdict : Static Frequency Tolerance : This test is PASSED only if the (Static Frequency accuracy given by RSA (or frequency tolerance if TCXO without calibration) + aging (on 5 years) + max temperature tolerance) < 20 ppm. Add all values in the "comment" line. DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelope" window). The "Narrow Band Power Distribution" requirement cannot be validated due to equipment limitations. PRS-UNB-MODEM-13 Static Frequency Tolerance EVALUATION PRS-UNB-MODEM-20 DBPSK Modulation envelop EVALUATION PRS-UNB-MODEM-21 Phase Measurement TOOL-ANALYSIS PRS-UNB-MODEM-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-30 TX Max Symbol duration TOOL-ANALYSIS PRS-UNB-MODEM-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-UNB-MODEM-40 Power Spectral Density TOOL-ANALYSIS PRS-UNB-MODEM-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-UNB-MODEM-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-110 Modulated Conducted Output Power MEASUREMENT PRS-UNB-MODEM-130 I/Q Wave record EVALUATION c Maximum Voltage Configuration Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Maximum Voltage" Power up the DUT in Maximum Voltage Run the Sigfox Test Mode TX-BPSK (with config 3, if Sigfox library older than V2.2.0) with your DUT Manual Verdict : Static Frequency Tolerance : This test is PASSED only if the (Static Frequency accuracy given by RSA (or frequency tolerance if TCXO without calibration) + aging (on 5 years) + max temperature tolerance) < 20 ppm. Add all values in the "comment" line. DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelope" window). 7
9 The "Narrow Band Power Distribution" requirement cannot be validated due to equipment limitations. PRS-UNB-MODEM-13 Static Frequency Tolerance EVALUATION PRS-UNB-MODEM-20 DBPSK Modulation envelop EVALUATION PRS-UNB-MODEM-21 Phase Measurement TOOL-ANALYSIS PRS-UNB-MODEM-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-UNB-MODEM-30 TX Max Symbol duration TOOL-ANALYSIS PRS-UNB-MODEM-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-UNB-MODEM-40 Power Spectral Density TOOL-ANALYSIS PRS-UNB-MODEM-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-UNB-MODEM-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-UNB-MODEM-110 Modulated Conducted Output Power MEASUREMENT PRS-UNB-MODEM-130 I/Q Wave record EVALUATION Execute with Test Mode : TX-PROTOCOL a Protocol Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" 1. If your Sigfox Library version is older than V2.2.0 Send a Sigfox Message with your DUT (payload 1 bit only : "1") Send a Sigfox Message with your DUT (payload 1 bit only : "0") Send a Sigfox Message with your DUT (payload 1 byte only : "40") Send a Sigfox Message with your DUT (payload 2 bytes only : "4041") Send a Sigfox Message with your DUT (payload 3 bytes only : "404142") Send a Sigfox Message with your DUT (payload 4 bytes only : " ") Send a Sigfox Message with your DUT (payload 5 bytes only : " ") Send a Sigfox Message with your DUT (payload 6 bytes only : " ") Send a Sigfox Message with your DUT (payload 7 bytes only : " ") 8
10 Send a Sigfox Message with your DUT (payload 8 bytes only : " ") Send a Sigfox Message with your DUT (payload 9 bytes only : " ") Send a Sigfox Message with your DUT (payload 10 bytes only : " ") Send a Sigfox Message with your DUT (payload 11 bytes only : " A") Send a Sigfox Message with your DUT (payload 12 bytes only : " A4B") Send a OOB Sigfox Message with your DUT 2. If your Sigfox Library version is at least V2.2.0 Run the Sigfox Test Mode TX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT b Uplink Encrypted Payload Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" Check "Activate Payload Encryption" Switch your device in encrypted mode 1. If your Sigfox Library version is older than V2.2.0 Send a Sigfox Message with your DUT (payload 1 bit only : "1") Send a Sigfox Message with your DUT (payload 1 bit only : "0") Send a Sigfox Message with your DUT (payload 1 byte only : "40") Send a Sigfox Message with your DUT (payload 2 bytes only : "4041") Send a Sigfox Message with your DUT (payload 3 bytes only : "404142") Send a Sigfox Message with your DUT (payload 4 bytes only : " ") Send a Sigfox Message with your DUT (payload 5 bytes only : " ") Send a Sigfox Message with your DUT (payload 6 bytes only : " ") Send a Sigfox Message with your DUT (payload 7 bytes only : " ") Send a Sigfox Message with your DUT (payload 8 bytes only : " ") Send a Sigfox Message with your DUT (payload 9 bytes only : " ") Send a Sigfox Message with your DUT (payload 10 bytes only : " ") Send a Sigfox Message with your DUT (payload 11 bytes only : " A") Send a Sigfox Message with your DUT (payload 12 bytes only : " A4B") 9
11 Send a OOB Sigfox Message with your DUT 2. If your Sigfox Library version is at least V2.2.0 Run the Sigfox Test Mode TX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT Uncheck "Activate Payload Encryption" in "Device" part Switch your device in not-encrypted mode c NVM Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" Send a Sigfox Message with your DUT (payload 1 byte only) : FIRST MESSAGE with Freq1 for frame 1, freq2 for frame 2 and freq3 for frame 3 in the "demodulation window" in RSA Power down (remove all USB cables and power supply) the DUT Send a Sigfox Message with your DUT (payload 1 byte only) : SECOND MESSAGE with Freq4 for frame 1, freq5 for frame 2 and freq6 for frame 3 in the "demodulation window" in RSA Manual Verdict : NVM Frequency Storage : After Power down/up, in the "demodulation window", the verdict should be : PASSED if freq1 is not egal to freq4 +/-100Hz, freq2 is not egal to freq5 +/-100Hz, freq3 is not egal to freq6 +/-100Hz. ("PASSED Verdict" example below). In "Demodulation" window, after power down/up, the Device (picture below) had not the same Sequence Number and same Frequencies as before. All NVM requirements should be "passed" in the "Info / Prereq / Equipment / Verdicts" window ("verdicts" subwindow). FAILED if freq1=freq4 +/-100Hz, freq2=freq5 +/-100Hz, freq3=freq6 +/-100Hz. 10
12 2.2.2.d Public Key Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" Switch in "public Key" in "Device Configuration", DYNAMIC part Configure the DUT in public Key Send a Sigfox Message with your DUT (payload 1 byte only) Wait for the end of the Sigfox message Switch in "private Key" in "Device Configuration", DYNAMIC part Configure the DUT in private Key e Frequencies Distribution Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Frequency Distribution" Run the Sigfox Test Mode TX-FREQ-DISTRIBUTION (the Sigfox Test Mode TX-PROTOCOL with config 34 if Sigfox library older than V2.2.0) with your DUT PRS-UNB-MODEM-11 Operational Frequencies Range TOOL-ANALYSIS PRS-UNB-MODEM-12 Operational Frequencies Distribution TOOL-ANALYSIS PRS-UNB-MODEM-80 AES TOOL-ANALYSIS PRS-UNB-MODEM-81 NVM Frequency Storage EVALUATION PRS-UNB-MODEM-82 NVM Sequence Number Storage TOOL-ANALYSIS PRS-UNB-MODEM-83 Public Key switch TOOL-ANALYSIS PRS-UNB-MODEM-84 Number of frames per message in Uplink mode TOOL-ANALYSIS PRS-UNB-MODEM-85 Legacy Uplink TOOL-ANALYSIS PRS-UNB-MODEM-86 Uplink Encrypted payload TOOL-ANALYSIS PRS-UNB-MODEM-100 TX Interframe Timing in Uplink mode TOOL-ANALYSIS PRS-UNB-MODEM-121 DUT Temperature level MEASUREMENT PRS-UNB-MODEM-122 DUT Voltage level MEASUREMENT Execute with Test Mode : RX-PROTOCOL a Downlink Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Standard Downlink" 11
13 Run the Sigfox Test Mode RX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT We recommand to keep a margin (middle of the allowed timings : between 1.4 and 4 )as the measurement with the SDR-DONGLE is not really accurate b Downlink Encrypted Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Standard Downlink" Check "Activate Payload Encryption" Switch your device in encrypted mode Run the Sigfox Test Mode RX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT Uncheck "Activate Payload Encryption" in "Device" part Switch your device in not-encrypted mode c Downlink Window : Start of Listening Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Start of Listening Window" Run the Sigfox Test Mode RX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT d Downlink Window : End of Listening Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "End of Listening Window" Run the Sigfox Test Mode RX-PROTOCOL (with config 1, if Sigfox library older than V2.2.0) with your DUT PRS-UNB-MODEM-88 Downlink Encrypted Payload TOOL-ANALYSIS PRS-UNB-MODEM-90 Number of repeated Uplink frame in bi-directional mode TOOL-ANALYSIS PRS-UNB-MODEM-101 TX Interframe Timing in Bi-directional mode TOOL-ANALYSIS PRS-UNB-MODEM-102 RX Start Of Listening TOOL-ANALYSIS PRS-UNB-MODEM-103 RX End Of Listening TOOL-ANALYSIS PRS-UNB-MODEM-104 RX to OOB(ack) Timing TOOL-ANALYSIS PRS-UNB-MODEM-120 RSSI level TOOL-ANALYSIS 12
14 2.2.4 Execute with Test Mode : RX-GFSK The "static Drift (Hz)" will be updated automatically by RSA according to the Test Mode : TX-BPSK static drift result. Select "Test Mode RX-GFSK" in "Device" part Click "Start Send GFSK" in "Device" part Run the Sigfox Test Mode RX-GFSK (with config 30, if Sigfox library older than V2.2.0) with your DUT Check the GFSK reporting and the RSSI value returned Click "Stop Send GFSK" in "Device" part The RX-GFSK level cannot be tested with the SDR-DONGLE (fixed level) but this test allow to validate the test mode RX-GFSK functionality. Manual Verdict : Downlink Only : This test is PASSED only if the DUT receives GFSK sent by Radio_Signal_Analyzer and reports the test result (as mentioned in the Sigfox Checklist ). Downlink Only-rssi : This test is PASSED only if the RSSI value displayed is GFSK RSSI +/- 2 db. PRS-UNB-MODEM-60 2GFSK 600bps TOOL-ANALYSIS PRS-UNB-MODEM-87 Downlink Only EVALUATION PRS-UNB-MODEM-89 Downlink Only-rssi EVALUATION Execute with Test Mode : RX-SENSITIVITY Select "Test Mode RX-SENSI" in "Device" part Run the Sigfox Test Mode RX-SENSI (with config 100, if Sigfox library older than V2.2.0) with your DUT The sensitivity cannot be tested with the SDR-DONGLE (fixed level) but this test allow to validate the test mode RX-SENSITIVITY functionality. PRS-UNB-MODEM-70 Sigfox Link Budget TOOL-ANALYSIS Execute with Test Mode : TX-SYNTH Select "Test Mode TX-SYNTH" in "Device" part Run the Sigfox Test Mode TX-SYNTH (with config 0, if Sigfox library older than V2.2.0) with your DUT 13
15 PRS-UNB-MODEM-10 Frequency Steps TOOL-ANALYSIS 3 Results Be careful, when saving the measurement, the result folder will be cleared. If the manual verdict is fail, add a note in the comment part to explain why (for example : The command doesn t work). Choose the proper verdict and fill in all "comments" line for all Pre-requisites in the "Info / Prereq / Equipment / Verdicts" window ("Prerequisites" subwindow). All commands have to be validated to have a "PASS" verdict and written in the comment part if it works properly. Export results when all requirements have been tested (all verdicts should be "FAIL", "INFO" or "PASS") : In "Info / Prereq / Equipment / Verdicts" window, Choose "Export Results" Open the result folder Select your DUT picture Select the I/Q record The SigfoxVerifiedCertification.tar.gz will contain all information (verdicts, comments, information) and shouldn t be modified in any way. All verdicts : "INCONCLUSIVE", cannot be validate with this equipment (due to the equipment s limitation). 14
Sigfox RF & Protocol Test Procedure RSA-SDR-DONGLE for RC3c-UDL-ENC
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Test Procedure RSA-SDR-DONGLE for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official
More informationSigfox Verified TM. Modem Test Plan for RC2-UDL-ENC. Version April 24, Public Use
Version 3.6.0 April 24, 2018 Sigfox Verified TM Modem Test Plan for RC2-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox Verified TM. Modem Test Plan for RC5-UDL-ENC. Version August 10, Public Use
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Test Plan for RC5-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox RF & Protocol Test Plan for RC2-UDL-ENC
Version 380 September 14, 2018 Sigfox RF & Protocol Test Plan for RC2-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable This document
More informationSigfox RF & Protocol Test Plan for RC3c-UDL-ENC
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Test Plan for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox RF & Protocol Test Plan for RC1-UDL-ENC-MONARCH
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Test Plan for RC1-UDL-ENC-MONARCH Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationBe prepared for Sigfox Verified TM Certification
Version 3.7.1 August 10, 2018 Be prepared for Sigfox Verified TM Certification Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationModem Specification for RC4-UDL-ENC
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Specification for RC4-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationBe prepared for Sigfox Verified TM Certification
Version 3.2.3 September 22, 2017 Be prepared for Sigfox Verified TM Certification Public Use Contents 1 Introduction 2 1.1 Scope...................................................... 3 1.2 Acronyms and
More informationSigfox RF & Protocol Specifications for RC3c-UDL-ENC
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Specifications for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationModem Specification for RC5-UDL-NOTENC-REP
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Specification for RC5-UDL-NOTENC-REP Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationSIGFOX_VERIFIED ULTRA NARROW BAND
_VERIFIED ULTRA NARROW BAND _VERIFIED ULTRA NARROW BAND MODEM REQUIREMENTS SPECIFICATION FOR NOTICE: THE CONTENT OF THIS DOCUMENT IS THE AND SHALL NOT BE DISCLOSED, DISSEMINATED, COPIED, OR USED EXCEPT
More informationBE PREPARED FOR SIGFOX READY TM CERTIFICATION
May 18th 2018 BE PREPARED FOR SIGFOX READY TM CERTIFICATION Public use Revision History Revision Number Date Change description 0.1 August 15 th, 2017 Initial spec 0.2 May 18 th, 2018 CW test time Content
More informationSIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION
October 5 th 2017 SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION Public use Revision History Revision Number Date Author Change description 0.1 August 15 th, 2017 B.Ray Initial
More informationDragonLink Advanced Transmitter
DragonLink Advanced Transmitter A quick introduction - to a new a world of possibilities October 29, 2015 Written by Dennis Frie Contents 1 Disclaimer and notes for early release 3 2 Introduction 4 3 The
More informationSV613 USB Interface Wireless Module SV613
USB Interface Wireless Module SV613 1. Description SV613 is highly-integrated RF module, which adopts high performance Si4432 from Silicon Labs. It comes with USB Interface. SV613 has high sensitivity
More information3 Definitions, symbols, abbreviations, and conventions
T10/02-358r2 1 Scope 2 Normative references 3 Definitions, symbols, abbreviations, and conventions 4 General 4.1 General overview 4.2 Cables, connectors, signals, transceivers 4.3 Physical architecture
More informationPXI WiMAX Measurement Suite Data Sheet
PXI WiMAX Measurement Suite Data Sheet The most important thing we build is trust Transmit power Spectral mask Occupied bandwidth EVM (all, data only, pilots only) Frequency error Gain imbalance, Skew
More informationRF Basics 15/11/2013
27 RF Basics 15/11/2013 Basic Terminology 1/2 dbm is a measure of RF Power referred to 1 mw (0 dbm) 10mW(10dBm), 500 mw (27dBm) PER Packet Error Rate [%] percentage of the packets not successfully received
More informationUSB Port Medium Power Wireless Module SV653
USB Port Medium Power Wireless Module SV653 Description SV653 is a high-power USB interface integrated wireless data transmission module, using high-performance Silicon Lab Si4432 RF chip. Low receiver
More informationRadiocrafts Embedded Wireless Solutions
High Performance RF Module for SIGFOX 868MHz Product Description The module is a compact surface-mounted product that measures only 12.7 x 25.4 x 3.5 mm. The module contains a communication controller
More information0.6 kbits/s, the modulation shall be aviation binary phase shift keying (A-BPSK).
SECTION 3 RF CHANNEL CHARACTERISTICS 3.1 Modulation 3.1.1 Modulation for channel rates 2.4 kbits/s and below. For channel rates of 2.4, 1.2 and 0.6 kbits/s, the modulation shall be aviation binary phase
More informationCatalog
- 1 - Catalog 1. Overview...- 3-2. Feature... - 3-3. Application...- 3-4. Block Diagram...- 3-5. Electrical Characteristics... - 4-6. Operation... - 4-1) Power on Reset... - 4-2) Sleep mode... - 4-3) Working
More informationWireless LAN Consortium OFDM Physical Layer Test Suite v1.6 Report
Wireless LAN Consortium OFDM Physical Layer Test Suite v1.6 Report UNH InterOperability Laboratory 121 Technology Drive, Suite 2 Durham, NH 03824 (603) 862-0090 Jason Contact Network Switch, Inc 3245 Fantasy
More informationGetting Started Guide
MaxEye IEEE 0.15.4 UWB Measurement Suite Version 1.0.0 Getting Started Guide 1 Table of Contents 1. Introduction... 3. Installed File Location... 3 3. Programming Examples... 4 3.1. 0.15.4 UWB Signal Generation...
More informationDoes The Radio Even Matter? - Transceiver Characterization Testing Framework
Does The Radio Even Matter? - Transceiver Characterization Testing Framework TRAVIS COLLINS, PHD ROBIN GETZ 2017 Analog Devices, Inc. All rights reserved. 1 Which cost least? 3 2017 Analog Devices, Inc.
More informationPXI LTE FDD and LTE TDD Measurement Suites Data Sheet
PXI LTE FDD and LTE TDD Measurement Suites Data Sheet The most important thing we build is trust A production ready ATE solution for RF alignment and performance verification UE Tx output power Transmit
More informationRF TESTING OF MODEMS EMBEDDED IN RADIOS
RF TESTING OF MODEMS EMBEDDED IN RADIOS J. W. Nieto Senior Scientist Harris Corporation RF Communications Division HFIA 2002, #1 Presentation Overview Overview Motivation Baseband Testing RF Testing RF
More informationOPP;SLARSEN;MVO;JFR;SSE;CRASMUSSEN;BBR BBR;CRASMUSSEN;MHANSEN;JFR. Date CET Initials Name Justification
Instruction Micro RF LinkX for 500 Series Document No.: INS12880 Version: 9 Description: The purpose of this document is to describe how to use the test tool Micro RF LinkX on devices based on the 500-series
More informationSystem Specification. EnOcean Certification Specification, part 1a Air Interface (ASK) V 1.1, RELEASED EXECUTIVE SUMMARY
EnOcean Certification Specification, part 1a Air Interface (ASK) V 1.1, RELEASED Approved for release: Sep 14, 2017 San Ramon, CA, USA, Dec 17, 2013 EXECUTIVE SUMMARY A proper review of every device shipped
More informationCatalog
- 1 - Catalog 1. Overview... - 3-2. Feature...- 3-3. Application... - 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 4-1) Power on Reset... - 4-2) Sleep mode...- 4-3) Working
More information4. BK2401/BK2421 Module RF test
4. BK2401/BK2421 Module RF test BK2401/BK2421 Module RF performance tests including transmit power (Power) Frequency (Frequency) and sensitivity (Sensitivity) test, and FCC / CE testing major FAIL in the
More informationetatronix PMA-3 Transmitter Tester Manual
etatronix PMA-3 Transmitter Tester Manual TxTester_Manual_rev1.02.docx 1 Version Version Status Changes Date Responsible 1 Release Initial release 01. Apr. 2015 CW 1.01 Release Updated Figure 4 for better
More informationGetting Started Guide
MaxEye ZigBee (IEEE 802.15.4) Measurement Suite Version 1.0.5.3 Getting Started Guide Table of Contents 1. Introduction...3 2. Installed File Location...3 3. Soft Front Panel...5 3.1 MaxEye ZigBee Signal
More informationRadio Frequency. Core System Package Part A. Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.
Core System Package Part A Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.0 + EDR This document defines the TSS and TP for qualification testing of the Bluetooth Wireless
More information1 UAT Test Procedure and Report
1 UAT Test Procedure and Report These tests are performed to ensure that the UAT Transmitter will comply with the equipment performance tests during and subsequent to all normal standard operating conditions
More informationTestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board
Page 1 of 16 ========================================================================================= TestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board =========================================================================================
More informationTC-3000C Bluetooth Tester
TC-3000C Bluetooth Tester Product Instructions TC-3000C Bluetooth Tester is able to analyze the data of every packet that is transmitted to the upper application protocol layer using the protocol stack,
More informationIQgig-RF TM Model B Technical Specifications
TECHNICAL SPECIFICATIONS IQgig-RF TM Model B Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-RF Test Controller Front Panel I/O Function Type Power
More informationSignal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features
Signal Forge TM Signal Forge 1000 TM Synthesized Signal Generator L 8.5 W 5.4 H 1.5 Digital and RF Tester with 1 GHz Range The Signal Forge 1000 combines a 1 GHz frequency range with three dedicated outputs
More informationTriarchy VSG6G1C USB Vector RF Signal Generator Operating Manual
Triarchy VSG6G1C USB Vector RF Signal Generator Operating Manual CW signal NB RF noise generator Analog modulation GMSK modulation Frequency sweeping Hopping with data Mod Page 1 of 27 8PSK GSM signal
More informationBasic Transceiver tests with the 8800S
The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS Basic Transceiver tests with the 8800S Basic Interconnects Interconnect
More informationETHERNET TESTING SERVICES
ETHERNET TESTING SERVICES 10BASE-Te Embedded MAU Test Suite Version 1.1 Technical Document Last Updated: June 21, 2012 Ethernet Testing Services 121 Technology Dr., Suite 2 Durham, NH 03824 University
More informationSeptember, Submission. September, 1998
Summary The CCK MBps Modulation for IEEE 802. 2.4 GHz WLANs Mark Webster and Carl Andren Harris Semiconductor CCK modulation will enable MBps operation in the 2.4 GHz ISM band An interoperable preamble
More informationISO/IEC INTERNATIONAL STANDARD
INTERNATIONAL STANDARD This is a preview - click here to buy the full publication ISO/IEC 24769-5 First edition 2012-12-15 Corrected version 2012-12-15 Information technology Automatic identification and
More informationLeCroy UWBSpekChek WiMedia Compliance Test Suite User Guide. Introduction
LeCroy UWBSpekChek WiMedia Compliance Test Suite User Guide Version 3.10 March, 2008 Introduction LeCroy UWBSpekChek Application The UWBSpekChek application operates in conjunction with the UWBTracer/Trainer
More informationEmbedded Radio Data Transceiver SV611
Embedded Radio Data Transceiver SV611 Description SV611 is highly integrated, multi-ports radio data transceiver module. It adopts high performance Silicon Lab Si4432 RF chip. Si4432 has low reception
More informationVARA HF Modem Specification Revision Oct30, 2017 Jose Alberto Nieto Ros, EA5HVK
VARA HF Modem Specification Revision 1.0.0 Oct30, 2017 Jose Alberto Nieto Ros, EA5HVK 1.0 Overview: VARA HF Modem is a propietary system developed by Jose Alberto Nieto Ros EA5HVK and can be used under
More informationLab 1: Analog Modulations
Lab 1: Analog Modulations Due: October 11, 2018 This lab contains two parts: for the first part you will perform simulation entirely in MATLAB, for the second part you will use a hardware device to interface
More informationETSI work on IoT connectivity: LTN, CSS, Mesh and Others. Josef BERNHARD Fraunhofer IIS
ETSI work on IoT connectivity: LTN, CSS, Mesh and Others Josef BERNHARD Fraunhofer IIS 1 Outline ETSI produces a very large number of standards covering the entire domain of telecommunications and related
More informationLoRaWAN. All of the gateways in a network communicate to the same server, and it decides which gateway should respond to a given transmission.
LoRaWAN All of the gateways in a network communicate to the same server, and it decides which gateway should respond to a given transmission. Any end device transmission can be heard by multiple receivers,
More informationIQgig-IF TM Technical Specifications
TECHNICAL SPECIFICATIONS IQgig-IF TM Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-IF Front Panel I/O Function Type Power Switch Power On/Off
More informationAN797 WDS USER S GUIDE FOR EZRADIO DEVICES. 1. Introduction. 2. EZRadio Device Applications Radio Configuration Application
WDS USER S GUIDE FOR EZRADIO DEVICES 1. Introduction Wireless Development Suite (WDS) is a software utility used to configure and test the Silicon Labs line of ISM band RFICs. This document only describes
More informationCatalogue
- 1 - Catalogue 1. Description... - 3-2. Features... - 3-3. Applications...- 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 5 - Power on Reset... - 5 - Working mode... -
More informationVST 6 GHz RF Vector Signal Transceiver (VST)
VST 6 GHz RF Vector Signal Transceiver (VST) 2016 Datasheet The most important thing we build is trust Key features Vector signal analyser and generator in a single 3U x 3 slot wide PXIe module 65 MHz
More informationMDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0
MDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0 Radyne Corporation 3138 E. Elwood St. Phoenix, AZ 85034 (602) 437-9620 Fax: (602) 437-4811 MDX420 Input Level Field Calibration Procedure AN227
More information10GECTHE 10 GIGABIT ETHERNET CONSORTIUM
10GECTHE 10 GIGABIT ETHERNET CONSORTIUM 10GBASE-T Clause 55 PMA Electrical Test Suite Version 1.0 Technical Document Last Updated: September 6, 2006, 3:00 PM 10 Gigabit Ethernet Consortium 121 Technology
More informationIQxel-M8W TM Multi-DUT Connectivity Test System
TECHNICAL SPECIFICATIONS IQxel-M8W TM Multi-DUT Connectivity Test System 2018 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports (A/B) Value
More informationSignal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Flexible Design Enables Testing of RF and Clock-driven Systems.
Signal Forge TM Signal Forge 1000 TM Synthesized Signal Generator L 8.5 W 5.4 H 1.5 Flexible Design Enables Testing of RF and Clock-driven Systems The Signal Forge 1000 combines a 1 GHz frequency range
More informationSV-MESH Mesh network series Catalogue
Catalogue 1. Description... 3 2. Features... 3 3. Applications... 3 4. Block Diagram... 4 5. Electrical Characteristics... 5 6. Operation... 5 Power on Reset... 5 Working mode... 6 Router mode... 8 Setting
More informationSTANAG 4529 CONFORMANCE TEST PROCEDURES
DEFENSE INFORMATION SYSTEMS AGENCY JOINT INTEROPERABILITY TEST COMMAND FORT HUACHUCA, ARIZONA STANAG 4529 CONFORMANCE TEST PROCEDURES APRIL 2004 Downloaded from http://www.everyspec.com (This page intentionally
More informationMulti-Channel RS-232 Serial RF Transceiver
RF-232 Multi-Channel RS-232 Serial RF Transceiver The RF-232 subassembly is a multi-channel serial radio transceiver. This device accepts and outputs standard serial data at one of three selectable data
More informationETHERNET TESTING SERVICES
ETHERNET TESTING SERVICES 10BASE-T Embedded MAU Test Suite Version 5.4 Technical Document Last Updated: June 21, 2012 Ethernet Testing Services 121 Technology Dr., Suite 2 Durham, NH 03824 University of
More informationIQxel-M2W TM R&D Connectivity Test System for Next Generation of Wi-Fi
TECHNICAL SPECIFICATIONS IQxel-M2W TM R&D Connectivity Test System for Next Generation of Wi-Fi 2019 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter
More informationTC-2000A Universal Pager Tester
TC-2000A Universal Pager Tester Product Description The TC-2000A Universal Pager Tester combines all of the test features required for pager testing within a single unit. Designed for R & D, manufacturing,
More informationLaboratory 5: Spread Spectrum Communications
Laboratory 5: Spread Spectrum Communications Cory J. Prust, Ph.D. Electrical Engineering and Computer Science Department Milwaukee School of Engineering Last Update: 19 September 2018 Contents 0 Laboratory
More informationApplication Note: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers
: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers FCT-1007A Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for the radio
More informationAERINOS SIGFOX IOT Solutions
1. Introduction Sigfox is a communication protocol that is used to read data from sensors through a fixed network of base stations. It works like a low cost SMS service. As an enduser, you only need to
More informationIQxel-M8W TM Multi-DUT Connectivity Test System
TECHNICAL SPECIFICATIONS IQxel-M8W TM Multi-DUT Connectivity Test System 2019 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports (A/B) Value
More informationTransceiver. Quick Start Guide. What is in the box What does it do How to build a setup Verification of the setup...
Transceiver Quick Start Guide What is in the box... 3 What does it do... 5 How to build a setup... 6 Verification of the setup... 10 Help and troubleshooting... 11 Technical specifications... 12 Declaration
More informationTesting Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer
Testing Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer Page 1 of 24 Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for
More informationTransmitter Tests in Accordance with the CTIA Plan for Wi-Fi Mobile Converged Devices
Products: R&S SMJ100A, R&S SMU200A, R&S SMATE200A, R&S FSQ6, R&S FSL6 Transmitter Tests in Accordance with the CTIA Plan for Wi-Fi Mobile Converged Devices Application Note 1MA107 In response to the growing
More informationLab 1: Analog Modulations
Lab 1: Analog Modulations October 20, 2017 This lab contains two parts: for the first part you will perform simulation entirely in MATLAB, for the second part you will use a hardware device to interface
More informationVIAVI VST. Data Sheet. 6 GHz RF Vector Signal Transceiver (VST)
Data Sheet VIAVI 6 GHz RF Vector Signal Transceiver () VIAVI Solutions The Vector Signal Transceiver () is an essential building block in RF communications test solutions supplied by VIAVI Solutions. Overview
More informationLABORATORY EXERCISES
LABORATORY EXERCISES You can write the answers on this sheet, or use a separate sheet if necessary. The deadline for returning these exercises can be seen on the course web page. If you run into problems,
More information2009 CubeSat Developer s Workshop San Luis Obispo, CA
Exploiting Link Dynamics in LEO-to-Ground Communications 2009 CubeSat Developer s Workshop San Luis Obispo, CA Michael Caffrey mpc@lanl.gov Joseph Palmer jmp@lanl.gov Los Alamos National Laboratory Paper
More information2320 cousteau court
Technical Brief AN139 Rev C22 2320 cousteau court 1-760-444-5995 sales@raveon.com www.raveon.com RV-M7 GX with TDMA Data By John Sonnenberg Raveon Technologies Corporation Overview The RV-M7 GX radio modem
More informationSPORTON International Inc.
SPORTON International Inc. No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, TaoYuan Hsien, Taiwan, R.O.C. Ph: 886-3-327-3456 / FAX: 886-3-327-0973 / www.sporton.com.tw CE RADIO TEST REPORT Applicant s company
More informationResearch on key digital modulation techniques using GNU Radio
Research on key digital modulation techniques using GNU Radio Tianning Shen Yuanchao Lu I. Introduction Software Defined Radio (SDR) is the technique that uses software to realize the function of the traditional
More informationELECTRICAL TESTING
ELECTRICAL TESTING 0839.01 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com TEST REPORT ACCORDING TO: FCC
More informationAN5008 Application note
Application note Using the S2-LP transceiver under the ARIB STD-T67 standard Introduction The S2-LP very low power RF transceiver for RF wireless applications in the sub-1 GHz band is designed to operate
More informationIQxel TM Next Generation Connectivity Test System
TECHNICAL SPECIFICATIONS IQxel TM Next Generation Connectivity Test System 2017 LitePoint, A Teradyne Company. All rights reserved. General Technical Specifications RF Analyzer Parameter Ports Value Input
More informationIQxel-M8 TM Multi-DUT Connectivity Test System
TECHNICAL SPECIFICATIONS IQxel-M8 TM Multi-DUT Connectivity Test System 2017 LitePoint, A Teradyne Company. All rights reserved. Overview of IQxel-M8 The IQxel-M8 is a manufacturing oriented, Multi-DUT
More informationLecture 10 Performance of Communication System: Bit Error Rate (BER) EE4900/EE6720 Digital Communications
EE4900/EE6720: Digital Communications 1 Lecture 10 Performance of Communication System: Bit Error Rate (BER) Block Diagrams of Communication System Digital Communication System 2 Informatio n (sound, video,
More informationKongsberg Mesotech Ltd.
Kongsberg Mesotech Ltd. Doc. No. : 974-00007904 Title : Digital Telemetry Notes elease : Version 1.4 Date : 2010-04-30 1. PUPOSE This document briefly describes the digital telemetry standards, formats
More informationProduct Specifications
Product Specifications LoRa USB Dongle LD-50H VER: 1.0 GlobalSat WorldCom Corporation 16F., No. 186, Jian 1 st Rd, Zhonghe Dist., New Taipei City 23553, Taiwan Tel: 886.2.8226.3799/ Fax: 886.2.8226.3899
More informationnrf Performance Test Instructions nrf24l01+ Application Note
nrf Performance Test Instructions nrf24l01+ Application Note All rights reserved. Reproduction in whole or in part is prohibited without the prior written permission of the copyright holder. November 2008
More informationG3P-R232. User Manual. Release. 2.06
G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...
More informationinstruction manual for Open LRS New Generation
instruction manual for Open LRS New Generation Table of contents 1. Important warnings 2. Hardware Overview 3 2.1 DTF UHF 4 Channel 4 2.2 HobbyKing RX 5 3. Instructions 3.1 Basic functions 6 3.2 Flashing
More informationPart A RADIO SPECIFICATION
Part A RADIO SPECIFICATION BLUETOOTH SPECIFICATION Version 1.0 B page 17 of 1082 CONTENTS 1 Scope...18 2 Frequency Bands and Channel Arrangement...19 3 Transmitter Characteristics...20 3.1 Modulation
More informationIQgig-RF TM Technical Specifications
TECHNICAL SPECIFICATIONS IQgig-RF TM Technical Specifications 2017 LitePoint, A Teradyne Company. All rights reserved. IQgig-RF is a scalable physical-layer test solution, tailored for 802.11ad (WiGig)
More informationSignal Generators for Anritsu RF and Microwave Handheld Instruments
Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis
More informationDoodle Labs Prism-WiFi Transceiver NM-4965 High Performance COFDM/MIMO Broadband Transceiver with minipcie
Doodle Labs Prism-WiFi Transceiver NM-4965 High Performance COFDM/MIMO Broadband Transceiver with minipcie Prism-WiFi Transceiver Overview Doodle Labs Prism-WiFi are frequency shifted long range Industrial
More informationnrf905-evboard nrf905 Evaluation board PRODUCT SPECIFICATION GENERAL DESCRIPTION
nrf905 Evaluation board nrf905-evboard GENERAL DESCRIPTION This document describes the nrf905-evboard and its use with the Nordic Semiconductor nrf905 Single Chip 433/868/915MHz RF Transceiver. nrf905-
More informationTEST REPORT OF THE. Inventek Systems
TEST REPORT OF THE 2.4 GHz es-wifi Module Models: IN CONFORMANCE WITH ETSI EN 300 328 V2.1.1 (2016-11) Harmonized EN covering essential requirements under article 3.2 of the Radio Equipment Directive (RED)
More informationA GENERAL SYSTEM DESIGN & IMPLEMENTATION OF SOFTWARE DEFINED RADIO SYSTEM
A GENERAL SYSTEM DESIGN & IMPLEMENTATION OF SOFTWARE DEFINED RADIO SYSTEM 1 J. H.VARDE, 2 N.B.GOHIL, 3 J.H.SHAH 1 Electronics & Communication Department, Gujarat Technological University, Ahmadabad, India
More informationGIGABIT ETHERNET CONSORTIUM
GIGABIT ETHERNET CONSORTIUM Clause 126 2.5G/5GBASE-T PMA Test Suite Version 1.2 Technical Document Last Updated: March 15, 2017 2.5, 5 and 10 Gigabit Ethernet Testing Service 21 Madbury Road, Suite 100
More informationPage : 1 / 221 TEST REPORT. Corning Optical Communications Wireless Inc.
Page : 1 / 221 TEST REPORT Report number Name RAPA15-O-035 Corning Optical Communications Wireless Inc. Applicant Logo Manufacturer Address Name Address 13221 Woodland Park Rd, Suite 400 Herndon, Virginia
More informationDoodle Labs Prism-WiFi Transceiver NM-4900 High Performance COFDM/MIMO Broadband Transceiver with minipcie
Doodle Labs Prism-WiFi Transceiver NM-4900 High Performance COFDM/MIMO Broadband Transceiver with minipcie Prism-WiFi Transceiver Overview Doodle Labs Prism-WiFi are frequency shifted long range Industrial
More information2.5G/5G/10G ETHERNET Testing Service
2.5G/5G/10G ETHERNET Testing Service Clause 126 2.5G/5GBASE-T PMA Test Plan Version 1.3 Technical Document Last Updated: February 4, 2019 2.5, 5 and 10 Gigabit Ethernet Testing Service 21 Madbury Road,
More information