Busbar and Modular Wiring Systems
|
|
- Laura Johns
- 5 years ago
- Views:
Transcription
1 Chapter 11 Busbar and Modular Wiring Systems 11.1 BUSBAR SYSTEM The wide range of busbar system is available and can be used for single or three-phase distribution to many types of applications ranging from lighting to heavy-duty machines in factories. This consists of copper or aluminium busbars mounted on insulators and enclosed in standard lengths of steel trunking, which are arranged to be fitted together thus forming a continuous busbar along the entire length of the distribution route. It is sometimes more economical to use busbars in place of long runs of sub-main cables. At intervals, typically every 1m, a tap-off point is provided. At these points tap-off units may be fitted; these can comprise unfused lighting units or power units protected with HRC fuses or circuit breakers. The units are provided with contact fingers which are designed to fit onto the busbars. Connections from these tap-off units to individual accessories, motors or other electrical equipment can be made by flexible connections, PVC sheathed cables, or conduit. The advantages of this system are that the trunking and busbars can be erected before the installation of the machinery, and the latter can be connected up and set to work as soon as they are installed. By bringing the heavy main feeders near to the actual loads, the circuit wiring is reduced to a minimum and voltage drop is lower than would otherwise be the case. Subsequent additions and alterations to plant layout can be easily accomplished, and where busbar sections have to be removed they can be used again in other positions. If a large number of small machines are to be fed it is usual to fit a distribution board near the trunking system and to protect this with a tap-off box fitted with HRC fuses of suitable capacity. Circuit wiring from the distribution board is usually carried out in heavy gauge screwed conduit. The system is comparatively expensive in first cost and, therefore, is best employed where heavy loads and a large number of machines have to be provided for. However, whilst material costs may be higher, installation is 255
2 256 PART j II Practical Work quicker and overall there may be cost benefits from using the system. Once installed there is very little depreciation or need for maintenance, and it has a high recovery value should it be necessary to dismantle and install it elsewhere. Several well-known manufacturers supply this trunking in various sizes, together with all necessary tees, bends, tap-off boxes and other accessories. Earth continuity is usually provided by an external copper earth link which ensures good continuity. Lighting trunking is also available whereby the trunking is fitted with integral busbars and the lighting fittings are simply clipped in place. Where there are long runs of busbar trunking it is necessary to provide expansion joints to take up any variations in length due to changes in temperature. These expansion joints usually take the form of a short length of trunking enclosing flexible copper braided conductors instead of solid busbars. It is advisable to provide one of these in every 30m run of trunking. Busbars are available with additional auxiliary conductors and these may be used for emergency lighting or self-test systems. Busbars are available with seven conductors as standard and some have smaller auxiliary conductors. No other conductors of any kind may be installed inside trunking containing bare copper busbars. All lids and covers must always be kept in position as a protection against vermin and also to avoid accidental contact with live busbars. The trunking should be marked prominently on the outside at intervals with details of the voltage of the busbars and the word DANGER. The conductors shall be installed so that they are not accessible to unauthorised persons. FIGURE 11.1 This type of lighting trunking has integral busbars carrying conductors for the supply to the luminaires. The 54-W twin fittings are available with either wide angle or semispecular narrow beam characteristics, enabling effective lighting from different heights. The trunking can be suspended from the building frame and, with the narrow beam reflectors, is suitable for high-bay illumination. The clip-in fittings can be arranged to pick up from different phases and the whole assembly can be carried out without the use of tools, a particular advantage when working at heights (W.T. Parker Ltd).
3 Chapter j 11 Busbar and Modular Wiring Systems 257 FIGURE 11.2 The busbar lighting units installed in a high-bay storage building. The lighting units have been installed and the installation is ready for the lids to be clipped on (W.T. Parker Ltd). Insulators shall be spaced to prevent conductors coming in contact with each other, with earthed metal or other objects. The conductors shall be free to expand or contract during changes of temperature without detriment to themselves or other parts of the installation. In damp situations the supports and fixings shall be of non-rusting material. If conductors are to be installed where exposed to flammable or explosive dust, vapour or gas, or where explosive materials are handled or stored, additional screens, caps and accessories should be fitted. These are able to improve the IP rating of the equipment. Where the trunking passes through walls or floors no space shall be left round the conductors where fire might spread. Fire barriers should be provided at these points inside the trunking. All runs of overhead busbar trunking must be capable of isolation in case of emergency or maintenance by means of an isolating switch fixed in a readily accessible position (Electricity at Work Regulations 1989 Regulation 12). Busbar System for Rising Mains A similar busbar system is frequently used for vertical rising mains for multistorey buildings. This usually consists of copper or aluminium busbars of capacities of A with two, three or four conductors. These are usually metalclad and are made in 4m sections, although all-insulated rising busbar systems are also obtainable. Tap-off boxes with fuselinks or fuseswitches can be provided for distribution to each floor where distribution boards can be fitted near the tap-off units. For these vertical runs it is very important that fire-resisting barriers be fitted inside the trunking at the level of each floor. These fire barriers can be purchased with the trunking, and the manufacturers will fit these in the required positions if provided with the necessary details. Where the trunking passes through floors,
4 a b (a) The pre-formed wiring units with plugs attached are conveniently stored and carried on this wheeled trolley preparatory to installation. All units are numbered to ensure correct installation. (b) Modular wiring installed ready for the distribution board to be secured and plugged in. c d (c) Distribut ion board in position with modular wiring looms fitted into the distribution cupboard, carried on a cable basket route. (d) Installing modular cable units on cable basket behind a suspended ceiling. e f (e) The junction box and cable basket enable a neat installation to be made and one where fault finding and alterations are easily accommodated at a later date. (f) Modular units installed in a wall partition. Sufficient spare cable is arranged to enable the fitting of switch and socket units and to carry out changes should these be needed at a later date (all M.W. Cripwell Ltd). FIGURE 11.3 Modular wiring.
5 Chapter j 11 Busbar and Modular Wiring Systems 259 whether in a specially formed riser cupboard, or run on the surface of a wall, it is necessary to ensure that the floor is made good by non-combustible material round the outside of the trunking to prevent the spread of fire. The supply for these runs of busbars is usually effected by a feeder box with provision for whatever type of cable is used. The manufacturers should be consulted as to the correct size of busbars to use, and IEE Regulations recommend that the maximum operating temperature should not exceed 90 C. Where rubber or PVC cables are connected to busbars operating at comparatively high temperatures the insulation and sheath must be removed for a distance of 150mm from the connection and replaced by suitable heat resisting insulation MODULAR WIRING SYSTEM Modular wiring is encountered in large sites where multiple installations of identical or similar design are required, or where speed of on-site installation is paramount in progressing the installation work. Modular wiring comprises factory assembled units with cables bunched together inside flexible conduit, and with end plugs pre-wired ready for assembly to matching sockets fitted to the equipment onsite. The units are made up in pre-arranged lengths with the cores of appropriate cross-section connected to the correct pins in the plugs. Home runs are used where the cross-sectional area of the cables is arranged to take the load of several circuits and these feed junction units from which modular final circuits are run. Whilst the initial cost of the equipment may well be greater than with traditional wiring, one main advantage of the system is that all the connections are made up in controlled conditions in a factory where the working environment is more stable than on a building site. A second advantage is that installation on-site is quick and easy. Once the cable containment is complete (typically using cable tray, basket or ladder), it is a matter only of selecting the correct pre-assembled modular cable, running it on the correct route and plugging in the end fittings to the on-site equipment plugs. It is, of course, important to select the correct loom for the individual application, these being identified by numbering during manufacture. Routing in rooms is usually inside the wall void and large diameter holes (100mm) allow the end plugs to be connected to individual switches, outlets or accessories. Any surplus length of the modular unit is fed back into the wall void once the switch or socket is fitted. This can then easily be recovered if any extensions or alterations are later required.
Risk Assessment & Safe Working Practice
RA Ref Number: 36 Revision: 3 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: Installing Trunking Next Review Date: 01/04/2019 Notes: Please refer to Safe Working
More informationCable Management Solutions with DLP TM
DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP
More informationZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial
More informationPROJECT: SUPPLY & INSTALL ELECTRICAL SWITCHBOARD AT SENGKURONG EXCHANGE PHASE 1, JLN TUTONG, BSB. SCOPE OF WORK The scope of work under Electrical Services shall include but not limited to the supply,
More informationCode for Design of Low Voltage Electrical Installations
UDC NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA 9=t $A~~~ iii iii *fij\fte p GB 50054-2011 Code for Design of Low Voltage Electrical Installations Translated English of Chinese Standard GB 50054-2011
More informationOptiLine 45 Floor boxes
OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with
More informationSizing conductors and selecting protection devices
Sizing conductors and selecting protection devices 04 POWER GUIDE 2009 / BOOK 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will
More informationConduit Systems. Chapter AN OVERVIEW OF CONDUIT INSTALLATION. Conduit Fittings
Chapter 9 Conduit Systems A conduit is defined as a tube or channel. In electrical installation work conduit refers to metal or plastic tubing. The most common forms of conduit used for electrical installations
More informationCablelink Plus Flush Technical
Cablelink Plus Flush Technical 107 technical hotline +44 (0)1268 563720 screeded floor systems is designed to provide power and data distribution highways in screeded floors. The robust system offers a
More informationSECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL
PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.
More informationRaised Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics
More informationRisk Assessment & Safe Working Practice
RA Ref Number: 34a Revision: 3 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: Installing Conduit - Flexible Next Review Date: 01/04/2019 Notes: Please refer to
More informationWanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking
Wanco Electric & Machinery Pte Ltd Cable Management Systems Cable Trunking About Wanco Wanco Electric and Machinery Pte Ltd is the leader in electrical construction materials. Through continued support
More informationFactory Assistance: Phone: Fax: Page 1
CABLE RUNWAY ACCESSORIES Radius Drop / Stringer Drop Provides 3 bend radius Radius drop fits 6, 12 and 18 runway made from 1-1/2 x 3/8 tubing Steel construction Includes (3) cable spools, (1) bolt, (1)
More informationArmoured Power and Control Cables to BS7917
1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit
More informationDLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation
DLP mini trunking Cable-grip It makes the installation easier and faster by containing all the wires inside the trunking body before the cover is clipped Comfortable implementation During installation,
More informationArmoured Power and Control Cables Fire Resistant
Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity
More informationNATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011
NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by
More informationChapter 6. WIRING SYSTEMS Safe Electrical Design
Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous
More informationCONTINUING EDUC ATION
3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com
More informationLow-Voltage Power Distribution and Electrical Installation Technology
Busbar trunking system Installation Manual 06/2011 Low-Voltage Power Distribution and Electrical Installation Technology Answers for infrastructure. SIVACON 8PS - Installation with LX system Low-voltage
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSample Scheme of Work
Sample Scheme of Work Aims for this topic Wider resources available Topic: Course / Program: Awarding Body used: Electrical Level 2 Technical Certificate in Electrical (8202-20) City & Guilds Level: 2
More information2394 EXAM PAPER. 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation
2394 EXAM PAPER 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation 2. There are various documents that are relevant to the Inspection and
More informationWarwick PVC Perimeter Trunking Systems
Warwick PVC Perimeter Trunking Systems Incorporating WARWICK MODULAR PVC RANGE The WARWICK PVC modular trunking range has been designed and manufactured using the expertise from two of the longest established
More informationCHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT
CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT A. General In a hazardous location grounding of an electrical power system and bonding of enclosures of circuits and electrical equipment in the
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION-16075 ELECTRICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Electrical identification to identify all electrical items for easy operation and maintenance including, but not limited
More information+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1
230-240V / 50-60Hz IP20 IK00 + - 2.0mm WARNING - THIS LUMINAIRE MUST BE EARTHED This luminaire has been tested and is manufactured to comply with BS EN 60598 : specification for general requirements and
More informationPrestige 2Com Technical
perimeter and distribution cable management Features System bend radius SOmm Exceeds Cat Se, 6 and 7 data cable requirements Attractive styling complementary to Logic Plus Aesthetic one piece fitting covers
More informationFINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes
FINAL - ER 70 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions.
More informationINTRODUCTION TO ZIPLINE
1:1 scale 57mm INTRODUCTION TO The Zipline is a self-contained pre-wired trunking and LED lighting system offering unparalleled flexibility in terms of lighting layout and scheme design. The Zipline combines
More informationMISTRAL SYSTEM IMPACT 2
MISTRAL 25-40A SYSTEM 100-400A IMPACT 2 400-6300A Megabarre Group represents the perfect fusion of a global offer, a highly-qualified service and a great working efficiency. The certificated quality of
More informationpower Knowledge The Hager Guide to current thinking on the regulations, protection and control of Klik lighting circuits.
Knowledge is power The Hager Guide to current thinking on the regulations, protection and control of Klik lighting circuits. Written by: Paul Sayer Technical Standards Manager for Hager Contents 2 Conductor
More informationELECTRICAL INSTALLATIONS REGULATIONS FOR
KINGDOM OF BAHRAIN ELECTRICITY AND WATER AUTHORITY REGULATIONS FOR ELECTRICAL INSTALLATIONS PREFACE This revised and enlarged edition of the wiring regulation replaces the 1985 edition of the Regulations
More informationStatus Date Prepared Reviewed Endorsed Approved
Discipline Engineering Standard NSW Category Electrical Title Reference Number PDS 05 (RIC Standard: EP 12 10 00 11 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards
More informationSo, let us investigate those parts of the Wiring Regulations that need to be considered in the early stages of the design procedure.
CHAPTER 1 Design Any design to the 17th Edition of the IEE Wiring Regulations BS 7671 must be primarily concerned with the safety of persons, property and livestock. All other considerations such as operation,
More informationSDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01
SEC DISTRIBUTION GROUNDING STANDARD SDCS-03 Part-II Rev.01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING Rev. 01 This specification is property of SEC
More informationPowerlink Plus Technical
CABLE MANAGEMENT mkelectric.co.uk TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mv/a/metre run L to E = 3.47 mv/a/metre run N to E = 3.47 mv/a/metre run EARTH
More information150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.
Technical information Aluminium trunking systems 295 Aluminium trunking capacity guide Trunking sizes up to 150mm Trunking sizes from 150mm to 200mm Trunking sizes over 200mm 105 1 2 105 3 Bench trunking
More information6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as
More information1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.
PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02
More informationBusbar Trunking Assembly
Busbar Trunking Assembly 00A-600A : 000V Horizontal and Vertical applications Suitable for Reliable Power Distribution to: > industry > highrise buildings - transformer to switchboards - switchboards to
More informationDESIGN CONSIDERATION OF ELECTRICAL DISTRIBUTION AND LIGHTNING PROTECTION SYSTEMS FOR HIGH-RISE BUILDING
DESIGN CONSIDERATION OF ELECTRICAL DISTRIBUTION AND LIGHTNING PROTECTION SYSTEMS FOR HIGH-RISE BUILDING 1 LAI LAI WIN, 2 KHIN THUZAR SOE 1 Electrical Power Engineering Department, Mandalay Technological
More informationArmoured Power and Control Cables to BS6883
Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in
More informationCI/SfB. October RockLink Integra. Installation system
CI/SfB (35) Xh2 October 2008 RockLink Integra Installation system RockLink Integra 1 6 Rockfon tiles with the E15 straight edge detail are suitable for installation using this system. 6 2 6 The following
More informationPinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.
604 Pinnacle Technical cable management perimeter and distribution www.mkelectric.co.uk Bench and Shelf Trunking Features l Available in a single or double configuration l May be fitted either direct to
More informationVinyl Cutter Instruction Manual
Vinyl Cutter Instruction Manual 1 Product Inventory Inventory Here is a list of items you will receive with your vinyl cutter: Product components (Fig.1-4): 1x Cutter head unit complete with motor, plastic
More informationSAVE THESE INSTALLATION INSTRUCTIONS
Light Without Boundaries LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT 7500003 8/4 Light Without Boundaries LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT GENERAL INSTALLATION WARNING To Reduce Risk Of Death,
More informationGROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL
GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL Revision 1.5 23 February 2007 : INSTALLERS MANUAL Table of Contents 2 INTRODUCTION.. 3 INSTALLER OPTIONS...... 4-11 ALARM SETTING
More informationMV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer
PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with
More informationUniversity of Central Florida Main Campus. Electric. Service and Meter Installations Requirements. Issued January 26 th, 2017.
University of Central Florida Main Campus Electric Service and Meter Installations Requirements Issued January 26 th, 2017 1 P a g e Table of Contents 1. GENERAL INFORMATION... 3 2. DEFINITIONS... 3 3.
More informationPREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!
PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling
More informationSECTION CABLE TRAYS
SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationTechnical guide. The technical guide provides all the additional information you need on our cable management products.
Technical guide 112 Technical guide The technical guide provides all the additional information you need on our cable management products. Trunking cable capacity Technical specifications Trunking Floor
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems
More informationElectrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installing with LI system
Introduction 1 Application planning 2 Electrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installation Manual Installation 3 Commissioning 4 Service and maintenance 5
More informationAlphabet By Ledra Brands Inc. SHOPline Trunk. example: SHOP TR WH. Base. Length. Base. Length SHOP. Shop. Optics ASL ASR DAS
Fixture : line Trunk The ZETA line is a great solution for energy conscious installations of new construction or retrofit of an existing space. line provides quality of light and simple installation, energy
More informationWIRE MESH CABLE TRAY
2014 WIRE MESH CABLE TRAY INSTALLATION GUIDE (CABLE BASKET) WIRE MESH CABLE TRAY (CABLE BASKET) PRODUCT INFORMATION - MAIN UNIT TECHNICAL PARAMETERS Materials Surface Finishing Thickness of coating Application
More informationMETER - INSTALLATION Pad Mount Transformer
ER 1-210-C PAGE 1 OF 5 USE: Pad mount transformer secondary compartment LATEST REVISION: PREVIOUS REVISION 10-01-12 ORIGINATED 0-94 PREVIOUS NUMBER ER 700, 10-01-86 Added specification for placement and
More informationTT W Wireless receiver Inline Switch
TT403 1000W Wireless receiver Inline Switch Product Description The TT403 is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does
More informationINSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R
INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R I. SUSPENDED INSTALLATIONS 1. Lay the two track halves on the floor with
More informationOPERATING INSTRUCTIONS
GB OPERATING INSTRUCTIONS Automatic Wedge Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION The is an automatic wedge welding machine for
More informationJourneyman's Practice Exam
Journeyman's Practice Exam [Time limit 4.0 hrs.] (The test is open book. I've started at the front of the Code Book and worked toward the back for instructional purposes. The real test will not be in order
More informationSECTION WIREWAYS FOR RADIOLOGY EQUIPMENT
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable
More informationInternational Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS
International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies
More informationREGATTA PATH LIGHT (RGP)
NEEDED FOR INSTALLATION: 5/64 & 5/32 Allen Wrench Waterproof Wire Connectors Warning Low Voltage Hot Surface Wear Gloves By Others Gloves IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
More information4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories
CONDUIT INSTALLATION ACCESSORIES Thinking of the environment We use only fully recyclable halogen-free thermoplastics, without harmful additives. No cadmium or asbestos in the colourants either. For total
More informationQuick Set Dovetail Jig
Quick Set Dovetail Jig FOR HELP OR ADVISE ON THIS PRODUCT PLEASE CALL OUR CUSTOMER SERVICE HELP LINE : 01509 500359 THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE DESIGN OR SPECIFICATION TO THIS PRODUCT
More informationREHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES. Building Solutions Automotive Industry
REHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES www.rehau.co.uk Building Solutions Automotive Industry PROFILA BENCH TRUNKING CONTENTS PAGE 1. Generalities.... 03 2. Fixing the Base.... 03 2.1 Adjacent
More information2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit
Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The
More informationArticle 225: Outside Branch Circuits And Feeders
Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)
More informationS.NO Description Quantity Rate Amount
INTERIOR WORKS NANDIMANDALAM BRANCH S.NO Description Quantity Rate Amount 1 Full height partition with laminate finish and glass. Providing & fixing partly glazed partly paneled Dry Wall Partition with
More informationUse RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING
Aluminium 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A R 95503111 95503131 95503131 95503141 95513111 95513131 95513131 95513141 95513151 L 95503211 95503231 95503231 95503241 95513211 95513231
More informationVI 3 - i TABLE OF CONTENTS
VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3
More informationWisconsin Contractors Institute Continuing Education
IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you
More informationTOA PROFESSIONAL POWER AMP
Operating Instruction Manual TOA PROFESSIONAL POWER AMP Model P-150M, P-300M TOA ELECTRIC CO, LTD. KOBE, JAPAN Contents Precautions... 2 General Description... 2 Features... 3 Specifications... 4~5 Performance
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR MOULDED - CASE CIRCUIT-BREAKER FOR VOLTAGES NOT EXCEEDING 1000 V ac OR 1500 V dc (FIRST REVISION) IPSS:1-04-004-11 IPSS BASED ON IS/IEC 60947(Part
More informationELECTRIC SLIP ROLL MACHINE. Model: ESR-1300X2.5/ESR-1300X4.5 ESR-1550X3.5/ESR-1580X2.0
ELECTRIC SLIP ROLL MACHINE Model: ESR-1300X2.5/ESR-1300X4.5 ESR-1550X3.5/ESR-1580X2.0 Operation Manual Table of contents I MAIN SPECIFICATION...2 II SAFETY INSTRUCTIONS.. 2 III OPERATION INSTRUCTIONS..4
More informationConstruction Measurement III SBQ3314. Electrical Installations : Single & Three Phase. Dr. Sarajul Fikri Mohamed
Construction Measurement III SBQ3314 Electrical Installations : Single & Three Phase Dr. Sarajul Fikri Mohamed Table of contents 1. Electrical installations: main components 2. SMM2 measurement rules for
More informationBUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.
BUSBAR TRUNKING SYSTEMS SERIES 25A-63A TABLE OF CONTENTS SERIES General Information 2-4 Project Information 5-6 Fittings Straight Lengths 7-8 Elbow Modules 8-9 Dilatation Module 9 Top Feed Module 10 End
More informationProtective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)
Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection) FIGURE 1.2 Fig.1 Earth fault loop path. Figure 1 shows the earth fault system which provides
More informationSteel Cable Management SECURITY AREAS TOTAL PROJECT SOLUTIONS
Steel Cable Management SECURITY AREAS TOTAL PROJECT SOLUTIONS Introduction to Tamlex Total project solution products for the complete cable management solution; Industrial, Warehouse, Retail and Offices
More informationINSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY
TT403- K (1000W) Wireless Inline Switch Product Description The TT403- K is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does
More informationDL102 Counter Loop Amplifier
DL102 Counter Loop Amplifier USER MANUAL MAN 234A Contents Overview...3 System Includes...3 Maintenance and Recycling Instructions...3 Safety Information...4 Quick Setup...5 Setup...6 Loop Amplifier...6
More informationPower Frequency Withstand Voltage On-site testing of 400 kv GIS
Power Frequency Withstand Voltage On-site testing of 400 kv GIS D. Anaraki Ardakani, A. Omidkhoda, M. Solati High Voltage Engineering Center ACECR Tehran, Iran Da_ardakani@yahoo.com Paper Reference Number:
More informationEPA104/254. User Manual.
EPA104/254 User Manual www.audac.eu ADDITIONAL INFORMATION This manual is put together with much care, and is as complete as could be on the publication date. However, updates on the specifications, functionality
More information4.0MM METAL CUTTING NIBBLER
596702 4.0MM METAL CUTTING NIBBLER Read through carefully and understand these instructions before use N3570 SAFETY INSTRUCTIONS PLEASE READ & UNDERSTAND THESE INSTRUCTIONS! STORE THESE INSTRUCTIONS IN
More informationGeneral Requirements. Technical Specification LVAC Systems
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks LVAC Systems NO: 423-1
More informationWire Mesh Cable Tray System for Channeling of Cable Wiring
Wire Mesh Cable Tray System for Channeling of Cable Wiring A Simple-to-Install basket for safe and proper installation of facility wiring in the ceiling and under the floor. Wall Mount Ceiling Mount s
More informationLes Hampson Cert Ed FSCTE, Chairman CAI Technical Committee
Making the Bond Les Hampson Cert Ed FSCTE, Chairman CAI Technical Committee After many man hours of deliberation and consultation the Code of Practice Electrical Safety Requirements for Signal Reception
More information/B
CHAPTER 1 Design Important terms/topics covered in this chapter: Assessment of general characteristics Basic protection Fault protection IP and IK codes The earth fault loop path Supplementary equipotential
More informationFlush Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 8 3.Products détails 9 to 18 4.Technical characteristics 19 to 21 1 RANGE. Lid
More informationER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)
ER 87 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationPow-R-Feed Systems Service Manual
Pow-R-Feed Systems Service Manual Important Safety Instructions Please read this manual carefully and follow its instructions. Improper use or failure to follow these instructions could result in serious
More informationResidual Current Operated Circuit-Breakers (RCCBs)
Product Overview Residual Current Operated Circuit-Breakers (RCCBs) Residual current operated circuit-breakers Number of poles Rated current A Rated residual current ma MW Auxiliary contacts can be mounted
More informationMaxLite Linear Strip ECO Series
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationCABTRAY Why you need it!
Cabtray CABTRAY Standard Range CABTRAY Load Carrying Capacity CABTRAY Tray Joiners CABLOK Composite Connectors CABTRAY Tray Joiners CABTRAY Support Systems CABTRAY Brackets CABTRAY Accessories CABTRAY
More informationArticle 250 Grounding & Bonding
Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education
More informationMarshall-Tufflex. Cable management catalogue.
Marshall-Tufflex Cable management catalogue www.marshall-tufflex.com 2 Contents An introduction to Marshall-Tufflex An introduction to the cable management catalogue, our customer service promise and the
More information