Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

Size: px
Start display at page:

Download "Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015"

Transcription

1 Optiva RF-Over-Fiber Design Tool User s Guide Revision 1.0 March 27, 2015

2 2015 Jenco Technologies Inc. All rights reserved. Every attempt has been made to make this material complete, accurate, and up-to-date. Users are cautioned, however, that Jenco Technologies Inc. reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors. All content included in this manual is the property of Jenco Technologies Inc. and is protected by U.S. copyright laws. You are not permitted to modify, distribute, reproduce, publish, transmit or create derivative documents from any material found on this site for any public or commercial purposes. "Jenco ", is a trademark of Jenco Technologies Inc. in the United States and other countries. Jenco s trademarks may not be used in connection with any product or service that is not Jenco s, in any manner that is likely to cause confusion among customers, or in any manner that disparages or discredits Jenco. Jenco Technologies Inc. 548 W So. Sandy, UT Phone: (801) Fax: (801)

3 Table of Contents RF-OVER-FIBER DESIGN TOOL OVERVIEW... 4 LOGIN... 5 CREATE USER ACCOUNT... 6 USER INPUTS... 8 FIBEROPTIC TRANSMITTER AND RECEIVER SELECTION... 9 FIBEROPTIC LINK PARAMETERS INPUT SIGNAL DEFINITION FIBEROPTIC TRANSMITTER/RECEIVER RF GAIN SETTINGS CWDM/DWDM SETTINGS FIBER AMPLIFIER (EDFA) SETTINGS EQUIPMENT CONFIGURATION PARAMTERS COMPUTED OUTPUTS SIGNAL INDEPENDENT PERFORMANCE Link Gain Noise Figure Spur Free Dynamic Range (SFDR) SFDR (2-tone) db Dynamic Range Input IP Input 1dB Compression Output IP Output 1dB Compression SIGNAL DEPENDENT PERFORMANCE RF Input Power RF Output Power Fiberoptic Receiver Input Optical Power Subsystem Carrier-to-Noise Subsystem Carrier-to-Interferer PARTS LIST AND MESSAGES PARTS LIST SPECIAL MESSAGES SUBSYSTEM BLOCK DIAGRAM SAVING CONFIGURATIONS RETRIEVING CONFIGURATIONS CONTACT US LOGOUT DOCUMENT REVISION HISTORY... 46

4 RF-Over-Fiber Design Tool Overview This document describes the use of the Optiva RF-Over-Fiber Design Tool. For a user-defined set of conditions, the Design Tool provides a means to estimate system fiberoptic subsystem RF performance for a variety of equipment and module settings. In addition to illustrating performance trades, the Design Tool also generates an equipment list based on current settings. The basic RF-over-fiber link is shown in Figure 1. The input to the system is a single RF cable connection consisting of a single, or multiple, RF carriers. The output to the system is the same RF signal attenuated (or amplified) by the link gain, and affected by the noise and distortion characteristics of the fiberoptic subsystem. Figure 1. Basic Fiberoptic Link Model The basic fiberoptic transmitter consists of an adjustable RF pre-amplifier and a laser diode. The basic fiberoptic receiver consists of a photodiode and an adjustable RF postamplier. The fiber portion of the link is modeled as a user defined length of fiber plus any passive losses that are present (e.g., patch panel losses, connector losses, splice losses). Optical amplification and wavelength multiplexing can also be modeled. These characteristics are discussed later in this document. 4 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

5 Login To launch the RF Over Fiber Design Tool, enter the Username and Password that was created previously. The RF Over Fiber Design Tool Login window is shown in Figure 2. After successfully logging in, the window shown in Figure 5 will be presented. Figure 2. Login Window 5 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

6 Create User Account If a user account does not currently exist, one must be created by clicking on the link shown in Figure 3. Figure 3. Link to Create User Account 6 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

7 The Create User Account page is shown in Figure 4. Accounts are used for various purposes. Within the RF Over Fiber Design Tool, users may create and save specific fiberoptic subsystem configurations. Configurations are associated with accounts, therefore one only has access to their saved configurations. Periodically, revisions will be made to the application. Users will be notified of this by means of the address provided for the User Profile. Figure 4. Create User Account Window All fields are required with the exception of Phone and the second Address line. There is input for Security Question and Answer for the purpose of forgotten password retrieval, however this feature has not currently been added to the application. Click the Create User button to proceed to the application main window. 7 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

8 User Inputs Upon successfully logging in to the Design Tool, the window shown in Figure 5 is presented. Figure 5. Start Window Four options are presented on this window. 1. Choose frequency band to start a new subsystem model 2. Load previously saved configuration 3. Go to Contact Us page to send a message to the administrator 4. Exit 8 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

9 Fiberoptic Transmitter and Receiver Selection Choosing an RF frequency band is the first step in defining the fiberoptic subsystem. Many of the additional options provided are dependent upon which frequency band is selected. L-Band roughly covers the bandwidth range MHz. Upon selecting the L-Band option, a drop down menu appears directly below as shown in Figure 6, which lists the options for L-Band fiberoptic transmitter. Figure 6. L-Band Fiberoptic Transmitter Options L-Band optical output power is listed in the dropdown menu. All other things being equial, higher output power from the transmitter results in a higher input optical, which in turn leads to better receiver noise performance. The lasers within transmitters may be uncooled or cooled. All other things being equal, cooled transmitters (i.e., lasers) have better noise performance (lower laser RIN). CWDM and DWDM transmitter options are also provided. Also, in cases where optical losses are high (high passive losses and/or long fiber distances), 1550 nm and DWDM transmitters may be optically amplified by using EDFAs. 9 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

10 The dual +6 dbm 1310 nm transmitter is essentially a higher density (x2) version of the standard +6 dbm 1310 nm transmitter. L-Band fiberoptic links also provide the option for a higher sensitivity fiberoptic receiver, shown in Figure 7. The higher receiver sensitivity provides higher RF gain and slightly better noise performance. High Sensitivity is usually desired when the optical input to the fiberoptic receiver is low (e.g., < -25 dbm), however High Sensitivity receivers can be used in all situations as the maximum optical input level is the same as the Standard version receiver. Datasheets for the L-Band fiberoptic transmitters and receivers can be found at the following. Figure 7. L-Band Receiver Sensitivity Option 10 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

11 The Satcom bands are specific to generally used antenna uplink and downlink frequencies. Upon selecting the Satcom option, a drop down menu appears directly below as shown in Figure 8, which lists the options for Satcom Band fiberoptic transmitters. Appropriate fiberoptic receivers are automatically selected. Figure 8. Satcom Transmitter/Receiver Sensitivity Option 11 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

12 The Wideband Microwave bands are shown in Figure 9. Upon selecting the Microwave option, a drop down menu appears directly below, which lists the options for Wideband Microwave fiberoptic transmitters. Appropriate fiberoptic receivers are automatically selected. The high frequency rolloff is provided in the transmitter dropdown list. The low frequency rolloff may be selected from the dropdown list to the right. Valid options are 50, 100, 500, and 1000 MHz. Note that some RF connector and lower rolloff options may not be available. These will be listed in the notes below the bar graphs. For example, when selecting the 40 GHz fiberoptic link, the lower frequency rolloff will be 2000 MHz if RF gain is added to either the transmitter or receiver. Figure 9. Satcom Transmitter/Receiver Sensitivity Option Datasheets for the Satcom and Microwave fiberoptic transmitters and receivers can be found at the following Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

13 Fiberoptic Link Parameters Fiberoptic link characteristics are entered into the Design Tool as shown in Figure 10. Passive losses are input as the sum of all passive losses in the fiberoptic link (e.g. fiber patch panel losses, optical connector losses, fiber splice losses, etc.). As a rule of thumb, a single patch panel loss is on the order of 0.5 db. Note: If CWDM or DWDM configurations are selected, the insertion losses for the optical MUX and DEMUX are automatically included otherwise and should NOT be included within this passive loss input. Fiber length is input as a distance in kilometers between the fiberoptic transmitter and the fiberoptic receiver. The Number of Optical Links entry represents the number of fiberoptic transmitter/receiver pairs. For non- CWDM/DWDM subsystems, this is essentially the number of optical fibers required in the subsystem. This input is primarily used for the computation of the Parts List. For CWDM/DWDM configurations, this input also determines the numer and size of WDM MUX/DEMUX pairs required. Figure 10. Fiberoptic Link Parameter Input 13 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

14 Input Signal Definition The characteristics of the RF input signal to the fiberoptic subsystem may also be input as shown in Figure 11. This input is used to calculate an estimate of the signal C/N (carrier-to-noise) and C/I (carrierto-interferer) at the subsystem output. The signal characteristics entered are assumed to be per transmitter. Signals are modeled as RF carrier tones. Number of Carriers is the total number of RF signals/carriers that make up the RF input signal. Channel Bandwidth represents the separation of the carriers (MHz). Carriers are assumed to be equally spaced. This bandwidth is essentially the noise bandwidth of a single carrier. The Channel Bandwidth is used to compute a carrier-to-noise ratio for the individual carriers. Signal Power represents the average RF power in a single carrier (dbm/carrier). All carriers are assumed to have the same signal level (i.e., average power). Figure 11. RF Input Signal Characteristics 14 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

15 Fiberoptic Transmitter/Receiver RF Gain Settings A key to optimizing the fiberoptic subsystem RF performance to meet particular requirements is the RF gain settings within the fiberoptic transmitters and receivers. All fiberoptic transmitters contain an RF preamplifier. All fiberoptic receivers contain an RF post-amplifier. The gain options common to all L-Band transmitters and receivers are shown in Figure 12. L-Band transmitters and receivers may be tuned over this entire range. That is, a single part number may be tuned over this range the transmitter and receiver part numbers (in the Parts List) do not change. Figure 12. L-Band RF Pre- and Post-Amplifier Gain Settings 15 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

16 The gain options common to all Satcom Band transmitters and receivers are shown in Figure 13. With respect to part numbers, Satcom Band transmitters and receivers may be tuned over either the higher end or the lower end of this RF gain range. All possible gain settings are shown in the dropdown list. For gain settings in the range of 0 15 db, a unique part number is generated. For gain settings in the rage db, a different unique part number is generated. That is, a single part number may be tuned over a 15 db range. Figure 13. Satcom Band RF Pre- and Post-Amplifier Gain Settings 16 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

17 The gain options common to all Wideband Microwave Band transmitters and receivers are shown in Figure 14. With respect to part numbers, each RF gain setting corresponds to a fixed amplifier gain level. That is, Wideband Microwave transmitters and receivers are configured with a fixed gain and this cannot be adjusted in the field. All possible gain settings are shown in the dropdown list, and the unique part numbers are generated and shown in the Parts List. Figure 14. Wideband Microwave Band RF Pre- and Post-Amplifier Gain Settings 17 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

18 CWDM/DWDM Settings L-Band fiberoptic transmitters may be selected to transmit coarse wavelength division multiplexed (CWDM) or dense wavelength division multiplexed (DWDM) wavelengths. The different wavelengths are multiplexed onto a single fiber using a MUX/DEMUX pair at either end of the fiberoptic link. Figure 15 shows the CWDM and DWDM fiberoptic transmitter options for L-band. Note that the wavelength MUX and DEMUX are inserted into the block diagram at the top of the page. 4-, 8-, and 16- wavelength MUX/DEMUX options are available. The size of the MUX/DEMUX is determined by the Number of Optical Links required, as shown in Figure 15. In this example, a 4-wavelength MUX/DEMUX is appropriate. If the Number of Optical Links is increased to 6, an 8-wavelength MUX/DEMUX would be required. Figure 15. L-Band CWDM and DWDM Option Settings If the Number of Optical Links is greater than 16, a suitable combination of 4-, 8-, and/or 16-wavelength MUX/DEMUX is used. For example, if the Number of Optical links is 20, an 8-wavelength and a 16- wavelength MUX/DEMUX are used. Such a subsystem would require two optical fibers (one for each MUX/DEMUX pair. In such a case, the subsystem RF performance parameters that are calculated and shown are based on the higher order (16 in this case) MUX/DEMUX pair. There is a subsystem RF performance difference between the two, as the optical insertion loss is different between the 4-, 8-, and 16-wavelength MUX/DEMUX pairs. 18 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

19 Satcom and Wideband Microwave fiberoptic transmitters may be selected to transmit dense wavelength division multiplexed (DWDM) wavelengths. The different wavelengths are multiplexed onto a single fiber using a MUX/DEMUX pair at either end of the fiberoptic link. Figure 16 shows the DWDM fiberoptic transmitter setting. Again, the wavelength MUX and DEMUX are inserted into the block diagram at the top of the page. 4-, 8-, and 16-wavelength MUX/DEMUX options are available. The size of the MUX/DEMUX is determined by the Number of Optical Links required, as shown in Figure 16. In this example, a 4-wavelength MUX/DEMUX is appropriate. If the Number of Optical Links is increased to 6, an 8-wavelength MUX/DEMUX would be required. Figure 16. Satcom and Wideband Microwave Band DWDM Option Setting If the Number of Optical Links is greater than 16, a suitable combination of 4-, 8-, and/or 16-wavelength MUX/DEMUX is used. For example, if the Number of Optical links is 20, an 8-wavelength and a 16- wavelength MUX/DEMUX are used. Such a subsystem would require two optical fibers (one for each MUX/DEMUX pair. In such a case, the subsystem RF performance parameters that are calculated and shown are based on the higher order (16 in this case) MUX/DEMUX pair. There is a subsystem RF performance difference between the two, as the optical insertion loss is different between the 4-, 8-, and 16-wavelength MUX/DEMUX pairs. 19 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

20 Fiber Amplifier (EDFA) Settings If the optical losses within the fiberoptic link are high enough to consider optical amplification, an erbiumdoped fiber amplifier (EDFA) option is provided. The saturated optical output power of the EDFA may be selected from the dropdown list. No EDFA, +14 dbm, +17 dbm, +20 dbm, and +23 dbm options are generally available. An L-Band EDFA implementation is shown in Figure 17. For L-Band, amplification is only available for 1550 nm and DWDM transmitters. When an EDFA option is selected, the block diagram at the top of the page adds this EDFA module. In the example below, the +23 dbm optical output power option is not provided, as this optical power would result in overloading the fiberoptic receiver. Figure 17. Optical Amplifier (EDFA) Option Setting The EDFA option works in the same way for Satcom and Wideband Microwave fiberoptic links. As all Satcom and Wideband Microwave transmitters are 1550 nm or DWDM, the EDFA option is available for all Satcom and Wideband Microwave fiberoptic links. 20 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

21 There exists also the option for placing an EDFA (EDFA pre-amplifier) preceding the fiberoptic receiver. An example is shown in Figure 18. The activation of the EDFA pre-amplifier option is dependent on the optical power level at this point in the fiberoptic link. If an EDFA at the transmitter side of the fiberoptic link is providing sufficient power at the input to the fiberoptic receiver, the EDFA pre-amplifier option will not be available. Therefore, in order to have the EDFA pre-amplifier option, it may be necessary to reduce the optical output power of the EDFA at the transmitter (or remove it altogether). Figure 18. Optical Pre-Amplifier (EDFA Pre-Amp) Option Setting Again, the EDFA pre-amplifier option is only available in fiberoptic links that are 1550 nm or DWDM. 21 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

22 Equipment Configuration Paramters The following figures describe the equipment settings required to determine equipment part numbers. These settings do not affect subsystem RF performance. L-Band subsystem equipment configuration settings are shown in Figure 19. Figure 19. L-Band Equipment Parameter Settings Depending on the selection of fiberoptic transmitter and RF connector interface, the L-Band subsystem may have slightly different RF passbands. The RF passband for the particular configuration is provided in one of the notes below the bar graphs. 22 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

23 The RF interface at the input and output of the fiberoptic subsystem (L-Band) may be selected from the following. 50Ω SMA (f) 50Ω BNC (f) 75Ω BNC (f) The Optiva platform provides the option of remote management and control via a plug-in management and control module. The M&C module provides an SNMP (Ethernet) interface for each chassis that houses a module. For Optiva 3RU 16-slot chassis, the M&C module would occupy one of the 16 card slots. For the 1RU 6-slot chassis, the M&C module would occupy a dedicated slot on the back of the equipment chassis, and would not consume one of the 6 available slots. If the M&C option is selected, a module will be added for each required equipment chassis. The 19 Rack Mounted option provides the following options. Front Access Rear Access No 16-slot and 6-slot chassis may be configured such that plug-in modules are accessed from the front or rear of a 19 equipment rack. If the option No is chosen, the subsystem will be configured using small flange mounted 1-, or 2-slot enclosures. If the subsystem requires more than 2 plug-in modules, the Parts List will default to a 19 rack mounted configuration. The Optiva 3RU 19 chassis provides slots for two (dual redundant) power supplies. Two power supplies per 3RU chassis is recommended, however it is optional. The 1RU 6-slot chassis has integrated swappable dual redundant power supplies as a baseline configuration. The Power Cord option provides the means to select the power cord connector for the AC/DC power supplies in the 3RU and 1RU chassis. The available options are shown below. North America European Union United Kingdom 23 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

24 The Satcom Band additional equipment settings are shown in Figure 20. The RF interface at the input and output of the fiberoptic subsystem may be selected from the following. 50Ω SMA (f) 50Ω K (f) The K connectors are generally used for the higher RF frequency fiberoptic links. Optical connectors may be chosen from the following. SC/APC FC/APC E2000/APC Figure 20. Satcom Band Equipment Parameter Settings 24 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

25 The Wideband Microwave Band additional equipment settings are shown in Figure 21. The RF and optical connector options are the same as the Satcom Band options. The upper end of the wideband passband is determined from the dropdown list on the left of the application window, as shown previously. The lower RF rolloff frequency may be selected as shown in Figure 21. Valid lower rolloff frequency options are as follows MHz 500 MHz 100 MHz 50 MHz The RF output of the fiberoptic subsystem may be either AC- or DC-coupled. Figure 21. Wideband Microwave Band Equipment Parameter Settings 25 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

26 Computed Outputs Signal Independent Performance Given the selected fiberoptic transmitter/receiver options, variable RF pre- and post-amplifier gain settings, and fiber link characteristics, the Design Tool computes estimates of the fiberoptic subsystem performance. The basic fiberoptic link RF performance metrics are shown in Figure 22. Figure 22. Computed Fiberoptic Subsystem RF Performance Link Gain RF subsystem link gain (db) is computed taking into account the RF amplifier gain settings, the conversion efficiencies of the laser diode and photodiode, and fiber passive and dispersive losses. 26 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

27 Noise Figure The computed Noise Figure represents the cascaded noise figures of all noise contributors in the fiberoptic subsystem. Spur Free Dynamic Range (SFDR) SFDR is the level where the power of the intermodulation distortion (IMD) products are equal to the fiberoptic subsystem noise floor. Therefore, the input signals are adjusted such that the difference between the desired output signal power and the noise floor would be equal to the difference between the desired signals and the spurs. Figure 23 shows a graphical representation of the SFDR. Figure 23. Spur Free Dynamic Range The SFDR can be calculated from the output IP3 as follows. SFDR =2/3(OIP3 N F ), where N F is the noise floor SFDR (2-tone) SFDR (2-tone) is a measure of SFDR with total integrated noise within the signal bandwidth. 27 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

28 1 db Dynamic Range 1dB Dynamic Range is the range between the minimum detectable signal (fiberoptic subsystem noise floor), and the fiberoptic subsystem input 1dB compression point, as shown in Figure 24. Figure 24. 1dB Dynamic Range 1dB Dynamic Range can be calculated as follows. 1dB DR = P 1dB (dbm) N F (dbm/hz), where P 1dB is the input 1dB compression point Input IP3 Input IP3 represents an expression of subsystem Output IP3 referred to the subsystem input. Input IP3 may be calculated as follows. IIP3 (dbm) = OIP3 G, where G is the link gain of the subsystem 28 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

29 Input 1dB Compression The Input 1dB Compression point (P1dB) is the input power level at which the subsystem gain drops by 1 db from its linear small signal value as shown in Figure 25. Figure 25. Input 1dB Compression Point 29 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

30 Output IP3 Output IP3 is a measure of subsystem nonlinearity resulting from inputting two tones of equal power and observing the the difference in power between an output fundamental tone and the power of one of the output third order products. A graphical depiction of Output IP3 is shown in Figure 26. Figure 26. Output IP3 Output IP3 may be calculated as follows. OIP3 (dbm) = 0.5(3P O P O3 ), where P O = power of output fundamental tone and P O3 = power of a 3 rd order product. Output 1dB Compression The Output 1dB Compression point (P OUT,1dB ) is the output power level at which the subsystem gain drops by 1 db from its linear small signal value. Output 1dB Compression may be calculated as follows. P OUT,1dB (dbm) = P IN,1dB + (G 1), where P IN,1dB is the input 1dB compression point and G is the link gain of the subsystem. 30 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

31 Signal Dependent Performance Signal power levels within the fiberoptic subsystem are shown in Figure 27. Figure 27. RF and Optical Signal Levels Within Fiberoptic Subsystem RF Input Power The total subsystem RF input power is the sum of input powers of all RF signal carriers. RF Output Power Total RF output power is total input power attenuated (or amplified) by the RF gain of the fiberoptic subsystem. 31 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

32 Fiberoptic Receiver Input Optical Power The receiver optical input power level is the fiberoptic transmitter optical output power attenuated by the passive and fiber losses within the fiber portion of the fiberoptic subsystem. It is generally desired to maximize the optical input power to the fiberoptic receiver as doing so improves the fiberoptic receiver noise performance. The fiberoptic subsystem carrier-to-noise and carrier-to-interferer computed values are as shown in Figure 28. Figure 28. Fiberoptic Subsystem C/N and C/I 32 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

33 Subsystem Carrier-to-Noise Carrier-to-noise (C/N) is computed using the per carrier RF Signal Power and Channel Bandwidth (noise bandwidth). C/N is the ratio of the carrier signal power to the integrated noise within the noise bandwidth. Increasing the carrier RF power improves C/N. Decreasing the subsystem noise figure (by increasing RF amplifier gain, etc.) improves C/N. Decreasing noise bandwidth improves C/N. Subsystem Carrier-to-Interferer Carrier-to-interferer (C/I) is computed using the per carrier RF Signal Power and the Number of RF Carriers. C/I is the ratio of the carrier signal power to the intermodulation products produced by the nonlinearities of the fiberoptic subsystem. Increasing the carrier RF power (and/or the number of RF carriers) degrades C/I as the total RF input power approaches the input 1dB Compression point of the fiberoptic subsystem. Increasing the subsystem input 1dB compression and IP3 levels (by decreasing RF amplifier gain, etc.) improves C/I. 33 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

34 Parts List and Messages Parts List For the given fiberoptic subsystem configuration, a Parts List is generated. This list includes all fiberoptic transmitter and receiver modules required to satisfy the current configuration. This list also includes required chassis, power supplies, M&C modules, CWDM/DWDM mux/demux modules, EDFAs, chassis blank front covers (to populate unused chassis slots), and fiber jumpers to connect colocated CWDM/DWDM modules, EDFAs, and transmitter/receiver modules within a 19 rack. An example Parts List is shown in Figure 29. Figure 29. Fiberoptic Subsystem Parts List 34 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

35 Special Messages The Design Tool provides a brief listing of context dependent messages as shown in Figure 30. Figure 30. Design Tool Special Messages 35 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

36 Subsystem Block Diagram For the given fiberoptic subsystem configuration, a simple block diagram is provided as shown in Figure 31. Figure 31. Fiberoptic Subsystem Block Diagram Optical passive and dispersive (fiber) losses are depicted within the optical link. The fiberoptic transmitter block is updated to reflect whether the transmitter laser diode is directly modulated (L-Band) or externally modulated (Satcom, Wideband Microwave). Any required EDFAs and MUX/DEMUX modules are included. If more than one size of MUX/DEMUX module is required within the subsystem, the larger is depicted in the block diagram. Note that the block diagram depicts a single optical fiber link. For example, if the Number of Optical Links is 4, the subsystem would consist of 4 of the links shown in the block diagram. For CWDM/DWDM subsystems, only one of the transmitter/receiver pairs is shown in the block diagram. 36 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

37 Saving Configurations Fiberoptic subsystem configurations may be saved for use at a later time. In order to save a configuration, click the Save Configuration button. A text box will appear. Type a name for the configuration and press Enter. The Save Configuration controls are shown in Figure 32. Figure 32. Saving Fiberoptic Subsystem Configuration 37 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

38 At this time, a unique configuration name must be entered. One cannot overwrite an existing configuration. If the new configuration name matches an existing name, please re-enter a new name as shown in Figure 33. Figure 33. Application Requires a Unique Configuration Name 38 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

39 Retrieving Configurations Previously saved fiberoptic subsystem configurations may be recalled by clicking the Load Configuration button. If no saved configurations exist, a message is displayed as shown in Figure 34, and nothing happens. Figure 34. Loading Saved Configurations, No Configurations Exist 39 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

40 If only one configuration currently exists when Load Configuration is clicked, it is loaded and the message appears as shown in Figure 35. Figure 35. Loading Saved Configurations, One Configuration Exists 40 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

41 If more than one configuration currently exists when Load Configuration is clicked, a dropdown list including all saved configurations will appear as shown in Figure 36. The configurations are ordered such that the most recently saved are on the top. When Load Configuration is clicked, the top item in the list is automatically loaded. A particular configuration may be loaded by scrolling down the dropdown list and selecting it. Figure 36. Loading Saved Configurations, Multiple Configurations Exist 41 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

42 Contact Us Feedback may be provided by clicking the Contact Us button as shown in Figure 37. Figure 37. Contact Us 42 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

43 The Contact Us form is shown in Figure 38. Enter an address in the appropriate box. This will provide a means to send replies to an address that may not be the same address associated in the User Profile. Enter any comments in the Comments box. If the inquiry involves a question/comment regarding a particular fiberoptic subsystem configuration, please reference that in the Comments. Such a configuration should have been previously saved, so that it can be retrieved. Click Send to send the message. After the message is sent, the application will return to the previous page. Figure 38. Contact Us Form 43 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

44 Logout To exit the application, click the Finish button as shown in Figure 39. Figure 39. Exiting the Design Tool 44 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

45 Click the Logout button, as shown in Figure 40, to logout from the RF Over Fiber Design Tool application. After clicking Logout, the RF Over Fiber Design Tool application Login window will be presented. One may close this tab on the browser. Figure 40. Exiting the Design Tool (continued) 45 Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

46 Document Revision History Initial Release 3/27/ Optiva RF-Over-Fiber Design Tool User Guide, Rev. 1.0

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links 5 MHz to 4 GHz Amplified Microwave Transport System The Optiva OTS-2 4 GHz Microwave Band transmitter and receiver are ideal to construct transparent fiber optic links in the 5 MHz to 4 GHz frequency range

More information

70/140 MHz IF Fiber Optic Link

70/140 MHz IF Fiber Optic Link 70/140 MHz IF Fiber Optic Link Product Description Features & Benefits IF-Band: 10 200 MHz Up to 10Km distance Powerful management capabilities via a front panel LCD and rack mounted SNMP 1550nm and CWDM

More information

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links 2 GHz to 4 GHz Amplified Microwave Transport System The Optiva OTS-2 4 GHz Microwave Band transmitter and receiver are ideal to construct transparent fiber optic links in the 5 MHz to 4 GHz frequency range

More information

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links MHz to 18 GHz Amplified Microwave Transport System The Optiva OTS-2 18 GHz Microwave Band transmitter and receiver are ideal to construct transparent fiber optic links in the MHz to 18 GHz frequency range

More information

Long-Haul DWDM RF Fiber Optic Link System

Long-Haul DWDM RF Fiber Optic Link System EMCORE Corporation - Broadband Division, Alhambra, CA, USA ABSTRACT EMCORE s vertically integrated ISO-9001 facility, staffed with our optics/rf engineering team, has been successfully designing and manufacturing

More information

FIBER OPTIC INTERFACILITY PLATFORMS

FIBER OPTIC INTERFACILITY PLATFORMS FIBER OPTIC INTERFACILITY PLATFORMS John A. MacDonald and Allen Katz Linear Photonics, LLC Nami Lane, Suite 7C, Hamilton, NJ 869 69-584-5747 macdonald@linphotonics.com LINEAR PHOTONICS, LLC Bringing Performance

More information

Headend Optics Platform (CH3000)

Headend Optics Platform (CH3000) arris.com Headend Optics Platform (CH3000) HT3580H Series Quad-Density Full Spectrum DWDM Transmitter System FEATURES DWDM transmitter: up to 16 wavelengths on ITU grid Hot plug-in/out, individually replaceable

More information

Optiva 18 GHz Unamplified Microwave (MW) Transport System

Optiva 18 GHz Unamplified Microwave (MW) Transport System The EMCORE Optiva Microwave Fiber Optic Transport System is a family of SNMP managed fiber optic transmitter and receivers that provide high-performance 0.05-18 Hz transport within the Optiva modular platform.

More information

LINEAR MICROWAVE FIBER OPTIC LINK SYSTEM DESIGN

LINEAR MICROWAVE FIBER OPTIC LINK SYSTEM DESIGN LINEAR MICROWAVE FIBER OPTIC LINK SYSTEM DESIGN John A. MacDonald and Allen Katz Linear Photonics, LLC Nami Lane, Suite 7C, Hamilton, NJ 869 69-584-5747 macdonald@linphotonics.com LINEAR PHOTONICS, LLC

More information

Digital Return System

Digital Return System SG4 DRT 2X 85 and MBN DRT 2X 85 Transmitters GX2 DRR 2X 85 and CHP D2RRX 85 Receivers FEATURES Allows return bandwidth expansion up to 85 MHz Easy node segmentation with 2X RF TDM Simplified logistics

More information

Digital Return System

Digital Return System arris.com Digital Return System SG4 DRT 2X 85 and MBN DRT 2X 85 Transmitters GX2 DRR 2X 85 and CHP D2RRX 85 Receivers FEATURES Allows return bandwidth expansion up to 85 MHz Easy node segmentation with

More information

FIBER OPTIC ANTENNA LINK OFW-5800/GPS. Compatible with a Wide Range of GPS Receivers Architectures. Logistically Supported with COTS Hardware

FIBER OPTIC ANTENNA LINK OFW-5800/GPS. Compatible with a Wide Range of GPS Receivers Architectures. Logistically Supported with COTS Hardware FIBER OPTIC ANTENNA LINK OFW-5800/GPS Compatible with a Wide Range of GPS Receivers Architectures Designed to Operate within the Naval Electromagnetic Environment Designed and Manufactured to Meet Naval

More information

Optiva Un-Amplified MW Transport 40 GHz System

Optiva Un-Amplified MW Transport 40 GHz System The EMCORE Optiva Microwave Fiber Optic Transport System is a family of SNMP managed fiber optic transmitter and receivers that provide high-performance 0.05-40 Hz transport within the Optiva modular platform.

More information

Optiva OTS-2 Ka-Band RF Fiber Optic Links

Optiva OTS-2 Ka-Band RF Fiber Optic Links Optiva OTS2 KaBand The Optiva OTS2 KaBand transmitter and receiver are ideal to construct downlink 18.300 to 21.200 Hz and uplink 28.350 to 31.000 Hz transparent fiber optic links for antenna remoting,

More information

Optiva OTS-2 Ku-Band RF Fiber Optic Links

Optiva OTS-2 Ku-Band RF Fiber Optic Links Optiva OTS2 KuBand The Optiva OTS2 KuBand transmitter and receiver are ideal to construct downlink 10.700 to 12.750 Hz and uplink.750 to 14.500 Hz transparent fiber optic links for antenna remoting, electronic

More information

INTRODUCTION. LPL App Note RF IN G 1 F 1. Laser Diode OPTICAL OUT. P out. Link Length. P in OPTICAL IN. Photodiode G 2 F 2 RF OUT

INTRODUCTION. LPL App Note RF IN G 1 F 1. Laser Diode OPTICAL OUT. P out. Link Length. P in OPTICAL IN. Photodiode G 2 F 2 RF OUT INTRODUCTION RF IN Today s system designer may be faced with several technology choices for communications links for satellite microwave remoting, cellular/broadband services, or distribution of microwave

More information

PR-12-B-M. 12 GHz PhotoReceiver, Module. Features. Applications. Functional Diagram

PR-12-B-M. 12 GHz PhotoReceiver, Module. Features. Applications. Functional Diagram PR-12-B-M 12 GHz PhotoReceiver, Module The Optilab PR-12-B-M is a 12 GHz bandwidth amplified PIN photodiode receiver module, designed for RF over fiber, antenna remoting, and broadband RF signals transmission

More information

CWDM Cisco CWDM wavelengths (nm)

CWDM Cisco CWDM wavelengths (nm) Cisco Enhanced Wavelength Division Multiplexing Product Line The Cisco enhanced wavelength-division multiplexing (EWDM) product line allows users to scale the speed and capacity of the services offered

More information

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System The bdr Digital Reverse 2:1 Multiplexing System expands the functionality of the GS7000 and GainMaker Reverse Segmentable

More information

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node 17.12.2012 1(12) CXX Series User Manual Teleste Corporation CXE880 Fibre node 17.12.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 3 Status monitoring card (optional)...

More information

1550nm external modulated optical transmitter operating manual

1550nm external modulated optical transmitter operating manual 1550nm external modulated optical transmitter operating manual Table of Contents Table of Contents...- 1 - Safety Instruction...- 2-1. Overview... - 3-1.1 About This Manual... - 3-1.2 Product Description...

More information

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO Testing of DWDM + CWDM high speed systems Christian Till Technical Sales Engineer, EXFO Need more bandwidth? xwdm - Class of WDM Devices Wavelength Division Multiplexing (WDM) : Access 2 channels 1310nm,

More information

Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module

Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module APPLICATION NOTE This application note describes the procedure for electro-optic measurements of both

More information

RF Over Fiber Design Guide Overview. Provided by OPTICAL ZONU CORPORATION

RF Over Fiber Design Guide Overview. Provided by OPTICAL ZONU CORPORATION RF Over Fiber Design Guide Overview Provided by OPTICAL ZONU CORPORATION Why use fiber? Transmission of RF and Microwave Signals via waveguides or coaxial cable suffers high insertion loss and susceptibility

More information

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM Kari Mäki 20.12.2012 1(7) 9000 INTLLIGNT FIBR PTIC PLATFRM Features The 9000 is an intelligent 4 output optical node of x product family. It is based on fixed platform but flexible modular solution, supporting

More information

Fiber Optic Transport Solutions for Satellite & Microwave Communications

Fiber Optic Transport Solutions for Satellite & Microwave Communications Fiber Optic Transport Solutions for Satellite & Microwave Communications Commercial, Government, Aerospace and Defense BASEBAND, IF, L, S, C, X, DBS, Ku, K, Ka, and Ultra-Wideband Signal Transport EMCORE

More information

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM Kari Mäki 4.4.2012 1(7) 9000 INTLLIGNT FIBR PTIC PLATFRM Features The 9000 is an intelligent 4 output optical node of x product family. It is based on fixed platform but flexible modular solution, supporting

More information

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880. Broadband Cable Networks March 3, 2008 1(10) CXX Series User Manual Teleste Corporation CXE880 Fibre Node Broadband Cable Networks March 3, 2008 2(10) Introduction The CXE880 is a fibre deep optical node

More information

OPC1600 MUX WDM OADM SPLITTER

OPC1600 MUX WDM OADM SPLITTER OPC1600 MUX WDM OADM SPLITTER OPC 1600 passive optical splitting platform The OPC 1600 optical splitting platform could, without affecting the original link, fully duplicates one or more copies of data

More information

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform Optoelectronics Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform Description The bdr Digital Reverse 4:1 Multiplexing System expands the functionality

More information

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split Data Sheet GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split The Cisco GainMaker High Output 4-Port Node with 40/52 MHz Split is designed to serve as an integral part of today s network architectures.

More information

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System Optoelectronics GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System Description The bdr Digital Reverse 2:1 Multiplexing System expands the functionality of the Scientific-Atlanta

More information

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes The Cisco Enhanced Digital Return (EDR) 85 System expands the functionality of Compact Segmentable Nodes by increasing the performance,

More information

Small Integrated Transmitter Unit SITU2400-XZ

Small Integrated Transmitter Unit SITU2400-XZ Small Integrated Transmitter Unit SITU2400-XZ 0.05 1 GHz, ITU-Grid DWDM Directly Modulated Self-Contained Transmitter Applications Cellular and PCS Antenna- Remoting Microwave Delay Lines Frequency Distribution

More information

WaveSmart Wave Division Multiplexing (WDM)

WaveSmart Wave Division Multiplexing (WDM) Application These products are needed when a passive multiplexing or demultiplexing unit is required in a central office environment. They are used in CATV headends and telephone company central offices.

More information

HDO772 C-BAND DWDM FIBRE TRANSMITTER

HDO772 C-BAND DWDM FIBRE TRANSMITTER Timo Rantanen 19.9.2012 1(6) HDO772 C-BAND DWDM FIBRE TRANSMITTER HDO772 is a high performance directly modulated C-band DWDM transmitter for forward path fibre optic links in CATV and FTTx networks. HDO772

More information

ULTRA BROADBAND RF over FIBER Transceiver OZ1606 Series Premium Grade 6 GHz

ULTRA BROADBAND RF over FIBER Transceiver OZ1606 Series Premium Grade 6 GHz FEATURES 30 MHz 6.0 GHz Bandwidth Rugged Dust tight Cast Metal housing, 3 x 5 x 1.25 @ ¾ lb 20 C to +65 C T OP Range LD Bias, LD Power and PD Monitoring and Alarms High SFDR Typically 113 (db/hz) 2/3 at

More information

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs: DATA SHEET CISCO DWDM GBICS The Cisco Dense Wavelength-Division Multiplexing (DWDM) Gigabit Interface Converter (GBIC) pluggables allow enterprise companies and service providers to provide scalable and

More information

Radio over Fiber technology for 5G Cloud Radio Access Network Fronthaul

Radio over Fiber technology for 5G Cloud Radio Access Network Fronthaul Radio over Fiber technology for 5G Cloud Radio Access Network Fronthaul Using a highly linear fiber optic transceiver with IIP3 > 35 dbm, operating at noise level of -160dB/Hz, we demonstrate 71 km RF

More information

ODN4P. Optical Distribution Node, Four Ports. About the Product

ODN4P. Optical Distribution Node, Four Ports. About the Product About the Product The Light Link Series 2, deep-fibre Optical Distribution Node ODN4P is a prime building block for highperformance networks, designed for adaptability, scalability and optional return-path

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET 8 Channels C53-C60 Dual Fiber DWDM Mux Demux W/Expansion Port, FMU Plug-in Module, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV10 2018 01 Overview

More information

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL The features mentioned in this Advanced OT-1000-HH Manual can be accessed only with the optional OT-NEC-A, Network Element

More information

TELESTE AC NODE SPECIFIC MODULES

TELESTE AC NODE SPECIFIC MODULES TELESTE AC NODE SPECIFIC MODULES AC 6310 Power supply module for Teleste AC8000 and AC8800 optical nodes. Can work alone or it can be operated parallel to split the work load and create the redundancy

More information

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual Q-SERIES Optical QFQR 200A-04 Series Return Path Optical Receiver Installation & Operation Manual Although every effort has been taken to ensure the accuracy of this document it may be necessary, without

More information

GainMaker High Output 4-Port Node

GainMaker High Output 4-Port Node GainMaker 1 GHz High Output 4-Port Node with 42/54 MHz Split The GainMaker High Output 4-Port Node is designed to serve as an integral part of today s network architectures. The GainMaker High Output 4-Port

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET 16 Channels C27-C42 Dual Fiber DWDM Mux Demux, with Monitor Port, Expansion Port and 1310nm Port, FMU 1U Rack Mount, LC/UPC Data Center & Cloud Computing Infrastruture

More information

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions Data Center & Cloud Computing DATASHEET Dual & Single Fiber DWDM OADM Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 DWDM OADM 01 1 Introduction FS.COM designs and offers all types

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC Data Center & Cloud Computing DATASHEET 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview Copyright 2009-2015

More information

Pass Cisco Exam

Pass Cisco Exam Pass Cisco 642-321 Exam Number: 642-321 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ Pass Cisco 642-321 Exam Exam Name : Cisco Optical SDH Exam (SDH) Braindumps

More information

t-series The Intelligent Solution for Wireless Coverage and Capacity

t-series The Intelligent Solution for Wireless Coverage and Capacity The Intelligent Solution for Wireless Coverage and Capacity All-Digital t-series - Going Beyond DAS With the increasing popularity of mobile devices, users expect to have seamless data services anywhere,

More information

Optical Delay Line Application Note

Optical Delay Line Application Note 1 Optical Delay Line Application Note 1.1 General Optical delay lines system (ODL), incorporates a high performance lasers such as DFBs, optical modulators for high operation frequencies, photodiodes,

More information

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions Data Center & Cloud Computing DATASHEET Dual & Single Fiber DWDM OADM Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 DWDM OADM 01 1 Introduction FS.COM designs and offers all types

More information

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split Optoelectronics Compact Model 90090 Fiber Deep Node 862 MHz with 42/54 MHz Split Description The Scientific-Atlanta Compact Model 90090 Fiber Deep Node is a small, low-cost, 110V AC powered node that addresses

More information

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000 Data Sheet Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000 The Cisco Enhanced Digital Return (EDR) 85 System expands the functionality of Cisco GS7000 and Cisco GainMaker Nodes by increasing

More information

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

A3422 XMTDR. Digital Return Optical Transmitter Module. Features A3422 XMTDR Digital Return Optical Transmitter Module The A3422 XMTDR digital return optical transmitter allows RF reverse path signals to be sent back to headend via a single fiber. The RF signal is routed

More information

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes Data Sheet Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes The Cisco Quad Optical Input Enhanced Digital Return (Q-EDR) 85 Receiver expands the Cisco

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC Data Center & Cloud Computing DATASHEET 8 Channels 1470-1610nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview The CWDM

More information

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES MODEL BLN100 1 1 GHz FIBER DEEP NODE STARLINE SERIES The BLN100 optical node is an essential building block in evolving Hybrid Fiber Coaxial (HFC) network architectures enabling amplifier to node conversions.

More information

Prisma II Optical Receivers

Prisma II Optical Receivers Optoelectronics Prisma II Optical s Description The Prisma II optical network is an advanced transmission system designed to optimize network architectures and increase reliability, scalability, and cost

More information

AC8800 INTELLIGENT FIBRE OPTIC PLATFORM

AC8800 INTELLIGENT FIBRE OPTIC PLATFORM Kari Mäki 27.5.2010 1(7) AC8800 INTLLIGNT FIBR PTIC PLATFRM The AC8800 is a dual active output node. It is based on fixed platform but flexible modular solution. It supports two optical receivers with

More information

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET FMU-MC09-A/B, Pair Packaged 9 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 Overview

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC Data Center & Cloud Computing DATASHEET 4 Channels 1270-1330nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview The CWDM

More information

HDO907 CATV FIBRE TRANSMITTER

HDO907 CATV FIBRE TRANSMITTER Timo Rantanen 18.2.2015 1(6) HDO907 CATV FIBRE TRANSMITTER HDO907 is a high performance, linear and directly modulated DFB laser transmitter for forward path fibre optic links in CATV and FTTx networks.

More information

HDO905 CATV FIBRE TRANSMITTER

HDO905 CATV FIBRE TRANSMITTER Timo Rantanen 23.8.2011 1(6) HDO905 CATV FIBRE TRANSMITTER HDO905 is a high performance, linear directly modulated DFB laser transmitter for forward path fibre optic links in CATV and FTTx networks. The

More information

ModuMAX High Power Amplifier Advancements

ModuMAX High Power Amplifier Advancements Tim Shroyer Chief Technology Officer General Dynamics ModuMAX High Power Amplifier Advancements ModuMAX - Over 15 Years of Exceptional Reliability General Dynamics ModuMAX High Power Amplifiers have provided

More information

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet The most important thing we build is trust 250 MHz to 6 GHz RF signal conditioning module for multi- UE, MIMO and Smartphone testing Four full

More information

SITU3018/ GHz Externally- Modulated Unamplified Transmitter

SITU3018/ GHz Externally- Modulated Unamplified Transmitter SITU3018/3118.0118 GHz Externally The EMCORE SITU3018/3118 (Small Integrated Transmitter Unit) is a highperformance externallymodulated transmitter for applications from 10 MHz to 18 GHz. The SITU family

More information

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA P.P. Hema [1], Prof. A.Sangeetha [2] School of Electronics Engineering [SENSE], VIT University, Vellore

More information

INSTRUCTION MANUAL OTOT-1000C-FQ WIDE-BAND 1550NM DIRECT-MOD QAM TRANSMITTER. 1,000 MHz Bandwidth / Optical Output Power is +9dBm (OTOT-1000C-09-FQ)

INSTRUCTION MANUAL OTOT-1000C-FQ WIDE-BAND 1550NM DIRECT-MOD QAM TRANSMITTER. 1,000 MHz Bandwidth / Optical Output Power is +9dBm (OTOT-1000C-09-FQ) INSTRUCTION MANUAL OTOT-1000C-FQ WIDE-BAND 1550NM DIRECT-MOD QAM TRANSMITTER 1,000 MHz Bandwidth / Optical Output Power is +9dBm (OTOT-1000C-09-FQ) Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026

More information

Compact Reverse Transmitters with DFB or CWDM Lasers

Compact Reverse Transmitters with DFB or CWDM Lasers Data Sheet Compact Reverse Transmitters with DFB or CWDM Lasers Cisco Compact Nodes can be configured with a variety of optical reverse transmitters to provide flexibility for use in multiple applications.

More information

User Manual. CSR-DMT channel selective digital TETRA repeater

User Manual. CSR-DMT channel selective digital TETRA repeater User Manual CSR-DMT channel selective digital TETRA repeater CSR-DMT channel selective digital TETRA repeater Rev 3-NM, Issued Nov. 2017 Page 2 of 16 TABLE OF CONTENTS TABLE OF CONTENTS... 3 CONTACT INFORMATION...

More information

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz FEATURES 30 MHz to 6.0 GHz Bandwidth Approx Size: 3 x 5 x 1.25 in. Weight ¾ pound 40 C to +5 C Operating Temperature LD/PD Monitoring & Alarm High Spurious Free Dynamic Range Automatic Optical Power Control

More information

Opti Max Optical Node Series

Opti Max Optical Node Series arris.com Opti Max Optical Node Series OM6000 1.2 GHz 4x4 HFC Segmentable Node FEATURES Supports 1.2 GHz Downstream and 204 MHz Upstream bandpass for DOCSIS 3.1 migration Integrated segmentation switches

More information

6.976 High Speed Communication Circuits and Systems Lecture 20 Performance Measures of Wireless Communication

6.976 High Speed Communication Circuits and Systems Lecture 20 Performance Measures of Wireless Communication 6.976 High Speed Communication Circuits and Systems Lecture 20 Performance Measures of Wireless Communication Michael Perrott Massachusetts Institute of Technology Copyright 2003 by Michael H. Perrott

More information

Mission Critical DAS Solution

Mission Critical DAS Solution Mission Critical DAS Solution In-Building Cellular Satellite Phone Coverage Mission Critical DAS solution for In-Building Systems provides a simple, low-cost, limitless bandwidth method to distribute multi-channel,

More information

GainMaker High Output Node 5-40/ MHz

GainMaker High Output Node 5-40/ MHz Optoelectronics GainMaker High Output Node 5-40/52-1002 MHz Description The GainMaker High Output Node is designed to serve as an integral part of today s network architectures, and combines the superior

More information

Time over Fiber. interfacility link systems

Time over Fiber. interfacility link systems Time over Fiber interfacility link systems 1 PPS CW/SINE STANDARDS IRIG GPS STABLE GROUP DELAY LOW ALLAN VARIANCE DUAL REDUNDANT POWER SUPPLIES FULLY HOT-SWAPPABLE UP TO SIX LINK MODULES PER 1RU RACK MULTIPLE

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 8157xA Optical Attenuators Technical Specifications March 2006 Agilent s 8157xA Variable Optical Attenuators

More information

AC8000 FIBRE OPTIC PLATFORM

AC8000 FIBRE OPTIC PLATFORM Kari Mäki 5.5.2008 1(7) AC8000 FIBR PTIC PLATFRM The AC8000 is a dual active output node. It is based on fixed platform but flexible modular solution. There is possible to have an optical receiver with

More information

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split Data Sheet GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split The GainMaker High Output Reverse Segmentable (RS) Node is designed to serve as an integral part of today s network architectures.

More information

Ultra-long Span Repeaterless Transmission System Technologies

Ultra-long Span Repeaterless Transmission System Technologies Ultra-long Span Repeaterless Transmission System Technologies INADA Yoshihisa Abstract The recent increased traffic accompanying the rapid dissemination of broadband communications has been increasing

More information

Prisma II 1 GHz 1550 nm Transmitters

Prisma II 1 GHz 1550 nm Transmitters Optoelectronics Prisma II 1 GHz 1550 nm Transmitters Description The Prisma II optical network is an advanced transmission system designed to optimize network architectures and increase reliability, scalability,

More information

Optical Passives and Accessories

Optical Passives and Accessories Optical Passives and ccessories Full line of optical passives and accessories High stability High reliability C-COR offers a complete line of DWDMs, CWDMs, WDMs, Couplers, and an Optical Shelf. Optical

More information

SITU3022/ GHz Externally- Modulated Unamplified Transmitter

SITU3022/ GHz Externally- Modulated Unamplified Transmitter The EMCORE SITU3022/32 (Small Integrated Transmitter Unit) is a highperformance externallymodulated transmitter for applications from 50 MHz to 22 GHz. The SITU family is a fullyintegrated unit that contains

More information

Compact Nodes and 90071

Compact Nodes and 90071 Fiber ptics Compact Nodes 90070 and 90071 Dedicated ptimized Nodes The 90070 receiver node is designed for long distance trunk applications to feed architectures of any density. Dual output with enhanced

More information

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET FMU-MC04E-A/B, w/expansion Port 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018

More information

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module INFORMATION & COMMUNICATIONS 11.1 Gbit/s Pluggable Small Form Factor DWDM Transceiver Module Yoji SHIMADA*, Shingo INOUE, Shimako ANZAI, Hiroshi KAWAMURA, Shogo AMARI and Kenji OTOBE We have developed

More information

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2017 100 GHz DWDM Passive Optical Add/Drop Multiplexers

More information

High-Fidelity RF over Fiber Links

High-Fidelity RF over Fiber Links High-Fidelity RF over Fiber Links 8 Uplander Way, Suite 2 Culver City, CA 923 Rugged, Small Form Factor Transmitter and Receiver Modules for RF over Optical Fiber Links Applications Fiber to the Antenna:

More information

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz Application Note Overview This application note describes accuracy considerations

More information

OPTICAL NODE TRUNK & DISTRIBUTION

OPTICAL NODE TRUNK & DISTRIBUTION OPTICAL NODE TRUNK & DISTRIBUTION OPTI 100RX - OPTI 200RX - OPTI 300RX Version 2 Page 1 OPTI INTRODUCTION OPTI is a broadband distribution node designed to be used as a compact, multiport optical node

More information

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Improved Analysis of Hybrid Optical Amplifier in CWDM System Improved Analysis of Hybrid Optical Amplifier in CWDM System 1 Bandana Mallick, 2 Reeta Kumari, 3 Anirban Mukherjee, 4 Kunwar Parakram 1. Asst Proffesor in Dept. of ECE, GIET Gunupur 2, 3,4. Student in

More information

Tutorials. OptiSys_Design. Optical Communication System Design Software. Version 1.0 for Windows 98/Me/2000 and Windows NT TM

Tutorials. OptiSys_Design. Optical Communication System Design Software. Version 1.0 for Windows 98/Me/2000 and Windows NT TM Tutorials OptiSys_Design Optical Communication System Design Software Version 1.0 for Windows 98/Me/2000 and Windows NT TM Optiwave Corporation 7 Capella Court Ottawa, Ontario, Canada K2E 7X1 tel.: (613)

More information

Prisma II 1 GHz SuperQAM Transmitter

Prisma II 1 GHz SuperQAM Transmitter Prisma II 1 GHz SuperQAM Transmitter The Prisma II optical networks allow for best in class architectures with increased reliability, scalability, and cost-effectiveness. The Prisma II 1 GHz SuperQAM Transmitter

More information

Why Using Fiber for transmission

Why Using Fiber for transmission Why Using Fiber for transmission Why Using Fiber for transmission Optical fibers are widely used in fiber-optic communications, where they permit transmission over long distances and at very high bandwidths.

More information

End of Life. Headend Optics Platform (HLP) SPL7210S/A. HL2 Series SUPRALink High Density DWDM Transmitter FEATURES PRODUCT OVERVIEW. arris.

End of Life. Headend Optics Platform (HLP) SPL7210S/A. HL2 Series SUPRALink High Density DWDM Transmitter FEATURES PRODUCT OVERVIEW. arris. arris.com Headend Optics Platform (HLP) SPL7210S/A HL2 Series SUPRALink High Density DWDM Transmitter FEATURES Compact size enables 20 DFB modules to fit in a 3RU platform DWDM technology optimizes HFC

More information

Compact Node Optoelectronics

Compact Node Optoelectronics ptoelectronics Compact Node 90075 Description The Compact Model 90075 Node is Scientific-Atlanta s latest addition to its family of Compact nodes. The node offers maximized coverage for network designs

More information

Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing

Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing Viyoma Sarup* and Amit Gupta Chandigarh University Punjab, India *viyoma123@gmail.com Abstract A RoF

More information

Sentinel 3: Speed, flexibility, certainty

Sentinel 3: Speed, flexibility, certainty ]= V1.2 Sentinel 3: Speed, flexibility, certainty Sentinel 3 is the most advanced RF over fiber test and measurement system for: EMP test and EMC conformance HIRF aircraft clearance Simulated lightning

More information

Passive WDM Networking

Passive WDM Networking Passive WDM Networking Company Introduction designs and markets all types of fibre optical Product portfolio: transmission products. Headquarted in Oslo, Norway, we serve Storage, Data and Telecom Networks

More information