Department of Physics

Size: px
Start display at page:

Download "Department of Physics"

Transcription

1 UNIVERSITY OF CALICUT Calicut University PO Thenjipalam, Malappuram Dist Kerala , India Department of Physics No. DP/46/FIST-II/ /11/2011 TENDER NOTICE Sealed competitive tenders are invited for the supply of the equipments as mentioned below, to the Department of Physics under the Department of Science and Technology Sponsored FIST programme. The last date for the receipt of the quotation is on , at AM. The tenders will be opened on 15/12/2011 at AM. The details of equipments, terms and conditions,etc, are furnished below. Sl. No. Equipment Cost of Tender Form EMD 1 Table Top X-Ray Diffractometer (XRD) Rs.416 1% of quoted rate 2 Basic AFM Facility(Atomic Force Rs.416 1% of quoted rate Microscope) 3 Sputtering System Rs.416 1% of quoted rate Separate quotations may be submitted for each item. Head of the Department

2 Item No 1 Table Top X-Ray Diffractometer (XRD) Details of Equipments Required X-Ray Diffraction system shall be table top type or equivalent for powder and thin film applications. The XRD should be computer controlled with necessary soft wares to carryout advanced processing using XRD data. The unit shall be complete in all respects to perform diffraction studies of powder as well as thin film samples. The system should also have following specifications: 1. X-ray generator (Microprocessor controlled): 30kV, 15mA(High Freq) 2. X-ray Tube: Target of Cu/Co-anode. Line and point focus to suite various applications. 3. Microprocessor Controlled Goniometer: Vertically mounted (Θ-Θ) type goniometer with angular 2θ movement range of or better. 4. Cabinet: The system should have a table mounting or floor-standing, interlocked doors.it should also have stringent safety requirements with respect to contamination of X-Rays and Radiation safety ensuring the negligible radiation outside the cabinet. 5. Optics: Programmable detector slit, divergence slit, anti-scatter slits (both on incident and diffracted beam sides) for low angle to high angle. Curved crystal diffracted beam monochromator for removing beta lines and sample fluorescence. 6. Sample Holders i) Sample Stage holder for powder diffraction: Sample stage for stationary samples for flat holders Sample stage with spinning capability (optional); multiple holders for powder samples ii) Thin Film holders with necessary soft wares for controlled pi rotation stage 7. Detector: Suitable low noise detector for powder and thin film samples. 8. Software : The system should interface with computer and analysis software should be capable of simultaneous data collection and analysis such as, powder pattern treatment, peak identification and peak indexing, Peak search, search-match with peak smoothing and background noise reduction,reitveld analysis based refinement, unit cell parameters space group search etc. The software should be able to carry out systematic non-parametric pattern matching for determining similarity of different samples through cross correlation of XRD Patterns. ICSD structure database with 5 year license should be quoted free or as option. 10. PC for integration: At least P-IV dual core processor, 4GB RAM, 500 GB HDD, DVD multi burner drive, Windows OS, TFT color monitor of 19 and color printer. 11. All operational consumable parts. 12. Warranty: At least one year and post warranty support for 5 years, based on AMC. 13. Demonstration & training at site for at least 2 days for 3 persons after installation. 14. Manual: For hardware and software are required both in hard and soft copy. 18. Cooling system: Water or oil Cooled 19. Quote separate price for base unit, software, chiller (if provided externally) etc 20. List accompanying free software for analysis Item No 2 Basic AFM (Atomic Force Microscope) Facility The multi mode Atomic Force Microscope System shall be equipped with all standard accessories for a high-resolution imaging (for measurements on thin films, dielectrics, electrochemical samples, nanodots, nanotubes, nanofibers and biological samples) consisting of a Scanning Probe Microscope (SPM) capable of Nanolithography, Nanomanipulation, and Multiple Mode Imaging Techniques

3 (AFM&STM). The following minimum instrument specifications are required. 1. Essential Measuring modes: In air: Contact AFM Lateral Force Mode (LFM) Resonant Mode AFM (semicontact + noncontact AFM) Phase Imaging Force Modulation Adhesion Force Imaging AFM spectroscopies AFM Nano Lithography and Nano-manipulation (Force and Electro-oxidative) Scanning Capacitance Microscopy Scanning Kelvin Microscopy Scanning Tunneling Microscopy (STM) 30pA-50nA (Optional) Scanning types: (Both types of scanning, by sample and by tip should be possible) 2. Scanners : Scanning range: x.x.z (x=70-100μm; z=5-10 μm) (+/-10%) Scanning range : x.x.x (x=1-2μm) (+/-10%) XY sample positioning: Range of sample positioning: 5x5 mm Positioning resolution: 5um 3.Optical System : Video-microscope with manual continuous zoom. Must include integrated top view optics and optical microscope with real-time color video display / image capture and cross hair (inside the AFM software). Resolution 1um or better Field of view 4.5x4.5 mm or better Magnification 5300x or better Color CDD camera and 20 LCD display 5. Vibration and acoustic isolation: Special cast metal hood for acoustic isolation and shielding,vibration Isolation Table. 6. Special fluid cells : Open liquid cell (liquids:- water or organic solvents) for Contact and Resonant modes 7. SPM Processor Control Electronics: Should contain all the control and monitor electronics the SPM e.g. DSP boards, Self diagnostics boards, Power supply units 8. Image analysis - Windows-based software Software must be a sole package for all modes and attachments with no need for additional software programs. It must be a licensed one and free of copying to any PC's of the institution. The image modification and presentation software should include at least following features: - Force-distance curve analysis - 2D Fast Fourier analysis - Plane-fit - High pass and low pass filters - Zoom in/out - Optional grid on images and curves - Variable shading and display angle, tilt - Color bar completely user definable 2D and 3D height presentation - Menu for image series presentation - Image and data export format at least: - Export to BMP, JPG, TIFF - Export to ASCII format and MatLab 9. Cantilever sets: 25 chips - for contact AFM; 50 chips - for noncontact modes; 5 chips - for MFM Standards - Set of 3 linear silicon gratings with silicon oxide calibrating steps ( 10. Future upgradeability:

4 More different scanners can be added including the scanners for operation in liquid environment; Can be upgraded with heating stage up to 100 deg. C; 11.Warranty 1-year warranty and regular service on AMC basis thereafter 12. Accessories UPS (2 hours backup) Vibration free table Data acquisition and processing unit Printer Sample preparation tools 13. Installation and training: Free installation and training for at least 3 persons immediately after installation Item No3: Sputtering System The unit shall be capable of performing high quality thin film deposition on various substrates for research applications. Separate quote must be given for RF unit and Magnetron units. It shall have the following applications. 1. Vacuum chamber: the chamber should be made from high quality stainless steel and leak tested to 8x10-8 torr-lit/sec. The design should be compatible structure for co-sputtering (DC and RF). 2. RF generator Power~ 300 W High Freq Operating Modes: real time Remote Analog/Digital Programming. 3. Magnetron sputtering assembly Size of the sputtering cathode ~ 2" (2 nos). Integrated gas inlet assembly Cross contamination shields Easy Target Replacement. External mounting. High deposition rate 4. Pulsed DC generator Pulsed DC Power Supply ~1000W DC or Pulsed DC Modes of Operation Arc count and short circuit protection Interlocks with indication. 4 Water cooled substrate holder (optional) Water cooled substrate holder (Anode) 5 Substrate heater The substrate holder should have at least 3.5 diameter fitted with S.S. Sheathed tubular flat heater operating on 230V AC for heating up to C. 6. Source shutter Manually operated shutter 7. Gas handling Provision for Ar and O gas feeding and control. 8. Substrate holder There should be a shutter on substrate / target to avoid cross contamination. Substrate holder assembly. Substrate holder should be isolated from ground for bias facility. Integrated Ar and Oxygen gas inlets assembly should be provide. Substrate should rotate with minimum speed and substrate temperature must reach upto C with PID Controller with digital display 9. Vacuum pumping system High vacuum pumping would be provided by a Turbo Molecular Pump and should be backed by a suitable double stage rotary vane pump. 10. Vacuum measuring systems Pirani and Penning gauges for accurate and quick measurements

5 11. Thickness monitor digital thickness monitor with calibration options along with at least 10 QCM 12. Chiller Integrated, high quality water cooling systems 13. Accessories Required for smooth operations 14. Safety High satiety precautions 15. Installation and training Proper installation within two weeks of the arrival of the plant at the institution. Free training for at least 3 persons by the engineers of the firm and regular monitoring advice for smooth operation during warranty period and afterwards on request. 16. Warranty At least one year after installation 17. Quote for each item separately Other Conditions 1. As per the University rule, the General Conditions for purchase( as given in the university web site, shall be applicable vis-a- vis, to the purchase of all items given in this tender notice. However, the Purchase Officer in this case will be the Head of the Department of Physics and correspondence and agreements shall be made to the Head. 2. The delivery schedule, which in no case exceed 12 weeks from the date of the placement of order, shall be included in the quotation. 3. Delivery and installation will be at Department of Physics, University of Calicut. 4. Details of installation and commissioning, and post-commissioning maintenance plan have to be mentioned clearly. 5. A list of institutions/universities in India should be attached where the quoted instrument is installed. 6. All possible Educational Discounts should be extended 7. Warranty: One years on site maintenance and warranty for the instrument with factory/well trained engineer. 8. Installation: Installation of the system at our site with your instruments, accessories, tools & tackles; deploying appropriate manpower as required, at your cost 9. Technical clarifications if any, has to be sought before submission of the formal quotation. 10. Insufficient information or suppressing of facts may cause invalidation of the quotation. Incomplete and conditional or late submitted tenders would be summarily rejected. 11. Period of validity: bids shall remain valid for acceptance for a period of 90 days from the date of opening. 12. The tender format can be downloaded from the university web site or can be had from the Office of the Department of Physics at working hours. 13. Quotation should reach the undersigned in duly superscribed the envelope with our reference number on or before 15th Dec 2011 at 11 am and should be addressed to Head Department of Physics, University of Calicut, Calicut University PO Kerala , India 14. The Head of the Department may accept or reject any or all the bids in part or in full without assigning any reason and does not bind himself to accept the lowest bid. The Department at its discretion may change the quantity / upgrade the criteria / drop any item or part thereof at any time before placing the Purchase Order. 15. Late tenders i.e. tender received after the due date and time of submission as mentioned below may liable to be rejected 16. In case of any dispute, the decision of the Head of the Department of Physics shall be final and binding on the bidders. 17. Opening of quotation: every quotation will be opened at the office of the Department of Physics,

6 University of Calicut, at the time and date mentioned below. The firm may send its accredited representative to witness the opening, if it so desires. 18. Performance guarantee: A bank guarantee/security deposit of 5 % of the total price is to be produced for issuing supply order to the successful bidder. 19. of quoted rate by way of DD in favor of the Head, Department of Physics University of Calicut, payable at State Bank of Travencore, University of Calicut Branch, 20. Cost of Tender form: A sum of Rs. 416, be paid as cost of tender form by way of remitting cash at University cash counter, or by a DD drawn in favour of Finance Officer, University of Calicut. Each tender should invariably accompany the chalan receipt or DD as documentary proof for the amount paid towards the cost of tender form to the University. 21. Important dates: Issue of tender notice 5 Nov 2011 Last date and time of receipt of tenders 15 Dec 2011, 11 am Date of opening of tenders 15 Dec 2011, am Head of the Department of Physics University of Calicut

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY IIT Bombay requests quotations for a high frequency conducting-atomic Force Microscope (c-afm) instrument to be set up as a Central Facility for a wide range of experimental requirements. The instrument

More information

CUJ/C0E-GEET/NIT/2014/1 Dated:

CUJ/C0E-GEET/NIT/2014/1 Dated: CUJ/C0E-GEET/NIT/2014/1 Dated: 24-12-2014 Sealed quotations are invited for the articles enclosed in the separate sheet subject to the termsand conditions given below.the quotation should be addressed

More information

Indian Institute of Technology Bombay

Indian Institute of Technology Bombay Specifications for High Resolution Scanning Probe Microscope Item Essential measuring modes with complete hardware and software. All the modes should be demonstrated during installation & training Scanners

More information

SPECIFICATION OF SOLAR CELL TESTER

SPECIFICATION OF SOLAR CELL TESTER SPECIFICATION OF SOLAR CELL TESTER A. Purpose: This equipment is to be used for testing of mono and multi crystalline silicon solar cells under standard testing conditions. The equipment shall be interfaced

More information

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled

More information

NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS

NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR-440022 TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS At NPTI (WR), NAGPUR, MAHARASHTRA 1 NATIONAL POWER TRAINING

More information

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure Optical Microscope On-axis optical view with max. X magnification Motorized zoom and focus Max Field of view: mm x mm (depends on zoom) Resolution : um Working Distance : mm Magnification : max. X Zoom

More information

NATIONAL DOPE TESTING LABORATORY JAWAHARLAL NEHRU STADIUM, EAST GATE, LODHI ROAD, NEW DELHI

NATIONAL DOPE TESTING LABORATORY JAWAHARLAL NEHRU STADIUM, EAST GATE, LODHI ROAD, NEW DELHI NATIONAL DOPE TESTING LABORATORY JAWAHARLAL NEHRU STADIUM, EAST GATE, LODHI ROAD, NEW DELHI 110 003 TERMS & CONDITIONS OF TENDER DOCUMENT FOR SUPPLY OF DESKTOPS, LAPTOPS, PRINTERS & UPS DATE OF ISSUE 09/10/2014

More information

Lecture 20: Optical Tools for MEMS Imaging

Lecture 20: Optical Tools for MEMS Imaging MECH 466 Microelectromechanical Systems University of Victoria Dept. of Mechanical Engineering Lecture 20: Optical Tools for MEMS Imaging 1 Overview Optical Microscopes Video Microscopes Scanning Electron

More information

DEPARTMENT OF ARCHITECTURE

DEPARTMENT OF ARCHITECTURE DEPARTMENT OF ARCHITECTURE Web : www.nitt.edu Phone : 0431-2503001 Short Tender Notification No.: NITT/ARCH/04/2012/ DRAWING TABLE Dated : 19-04 -2012 (Retender Those previously quoted for this tender

More information

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress AutoMATE II Micro-area X-ray stress measurement system Highly accurate micro area residual stress The accuracy of an R&D diffractom dedicated residua In the past, if you wanted to make highly accurate

More information

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues Instructions XRD 28.10.2016, Sami Suihkonen General issues Be very gentle when closing the doors Always use Cu attenuator when count rate exceeds 500 000 c/s Do not over tighten optical modules or attach

More information

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential

More information

Lasers should be fiber coupled using - Single mode fiber with angled FC connector Solid state 532 nm,/514 nm, 633, 785nm, 20 mw

Lasers should be fiber coupled using - Single mode fiber with angled FC connector Solid state 532 nm,/514 nm, 633, 785nm, 20 mw Monochromator Aberration-corrected, Raman imaging with error-correction based on closed feedback loop of scanner. 3D imaging and depth profile based on confocal configuration with Raman Depth resolution

More information

Microscopic Structures

Microscopic Structures Microscopic Structures Image Analysis Metal, 3D Image (Red-Green) The microscopic methods range from dark field / bright field microscopy through polarisation- and inverse microscopy to techniques like

More information

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples Cutting-edge Atomic Force Microscopy techniques for large and multiple samples Study of up to 200 mm samples using the widest set of AFM modes Industrial standards of automation A unique combination of

More information

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+) Standard Operating Procedure of Atomic Force Microscope (Anasys afm+) The Anasys Instruments afm+ system incorporates an Atomic Force Microscope which can scan the sample in the contact mode and generate

More information

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation Miniflex Rigaku/ Miniflex X-ray Diffractometer System Rigaku Corporation Rigaku/ Miniflex X-ray Diffractometer System 1. Introduction Rigaku s general purpose X-ray diffractometer systems are broadly classified

More information

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation 238 Hitachi Review Vol. 65 (2016), No. 7 Featured Articles Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation AFM5500M Scanning Probe Microscope Satoshi Hasumura

More information

Nanovie. Scanning Tunnelling Microscope

Nanovie. Scanning Tunnelling Microscope Nanovie Scanning Tunnelling Microscope Nanovie STM Always at Hand Nanovie STM Lepto for Research Nanovie STM Educa for Education Nanovie Auto Tip Maker Nanovie STM Lepto Portable 3D nanoscale microscope

More information

NIT No. CDI/ NIT/ 004/ Dated: 18 th October 2017

NIT No. CDI/ NIT/ 004/ Dated: 18 th October 2017 NIT No. CDI/ NIT/ 004/ 2017-18 Dated: 18 th October 2017 Tender Documents for supply of IT Equipments for Pashmina Testing Lab. Cost of Tender Documents: Sale of Tender Documents: Rs. 300/- (Rupees Three

More information

Certificate by the Architect: Certified that no addition and deletion has been made to the tender documents downloaded from the IIT Madras web site.

Certificate by the Architect: Certified that no addition and deletion has been made to the tender documents downloaded from the IIT Madras web site. INDIAN INSTITUTE OF TECHNOLOGY MADRAS ENGINEERING UNIT CHENNAI 600 036 NOTICE INVITING TENDERS FOR APPOINTMENT OF ARCHITECTURAL CONSULTANT No: 35/ ARC / 2013 14 TECHNICAL BID COVER 2 NAME OF WORK: Providing

More information

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE Jadavpur, Kolkata Tender No.: IACS/BC/PKD/DST/ Date:

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE Jadavpur, Kolkata Tender No.: IACS/BC/PKD/DST/ Date: INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE Jadavpur, Kolkata 700 032 Tender No.: IACS/BC/PKD/DST/2012-13 Date: 23.05.2012 Sub: Dynamic Rotational & Oscillatory Research Grade Rheology Instrument

More information

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY References: http://virlab.virginia.edu/vl/home.htm (University of Virginia virtual lab. Click on the AFM link) An atomic force

More information

Tender Document. National Centre of Excellence in Analytical Chemistry, ISSUED BY: University of Sindh, Jamshoro.

Tender Document. National Centre of Excellence in Analytical Chemistry, ISSUED BY: University of Sindh, Jamshoro. National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro. Tender Document Potentiostat ISSUED TO M/s. ------------------------------------------------ Purchase Date: ----------------------------------

More information

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM) Investigate in magnetic micro and nano 5.3.85- Related Topics Magnetic Forces, Magnetic Force Microscopy (MFM), phase contrast imaging, vibration amplitude, resonance shift, force Principle Caution! -

More information

Advanced Nanoscale Metrology with AFM

Advanced Nanoscale Metrology with AFM Advanced Nanoscale Metrology with AFM Sang-il Park Corp. SPM: the Key to the Nano World Initiated by the invention of STM in 1982. By G. Binnig, H. Rohrer, Ch. Gerber at IBM Zürich. Expanded by the invention

More information

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System --

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System -- THE RIGAKU JOURNAL VOl. 8 / NO. 1 / 1991 HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM 3726 --Wafer Surface Analysis System -- 1. Introduction System 3726 utilizes the total reflection

More information

Introduction: Why electrons?

Introduction: Why electrons? Introduction: Why electrons? 1 Radiations Visible light X-rays Electrons Neutrons Advantages Not very damaging Easily focused Eye wonderful detector Small wavelength (Angstroms) Good penetration Small

More information

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three

More information

Technical Specifications SECTION C

Technical Specifications SECTION C Page 1 of 12 INSTITUTE FOR PLASMA RESEARCH Technical Specifications SECTION C Design, Fabrication, assembly, testing and supply of Filter polychromators & associated components and demonstration of performance

More information

Scientific Instruments to the Future. Angstrom Advanced Inc.

Scientific Instruments to the Future. Angstrom Advanced Inc. Scientific Instruments to the Future Angstrom Advanced Inc. Summary As an leading supplier of Scientific Instruments, Angstrom Advanced has extensive experiences in designing, manufacturing, building and

More information

WRIST ARTHROSCOPY SYSTEM

WRIST ARTHROSCOPY SYSTEM DESCRIPTION 1 1 lot 10,648,751.67 Brand new, not reconditioned including its Parts & Accessories 1. Wrist Arthroscope a. HD wide angle 30-degree small joint arthroscope i. One (1) short scope (1 piece)

More information

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy - Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy Yongho Seo Near-field Photonics Group Leader Wonho Jhe Director School of Physics and Center for Near-field

More information

Niobium Coating of Copper Cavities by UHV Cathodic Arc: progress report

Niobium Coating of Copper Cavities by UHV Cathodic Arc: progress report Niobium Coating of Copper Cavities by UHV Cathodic Arc: progress report L. Catani, A. Cianchi, D. Digiovenale, J. Lorkiewicz, Prof. S. Tazzari, INFN-Roma "Tor Vergata", Italy Roberto Russo, Istituto di

More information

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information THE RIGAKU JOURNAL VOL. 11 I NO.2 I 1994 Product Information X-RAY MICRODIFFRACTOMETER PSPC/MDG 2000 1. Introduction The analysis of X-ray diffraction patterns is well known as an effective means of obtaining

More information

Leading in Desktop SEM Imaging and Analysis

Leading in Desktop SEM Imaging and Analysis Leading in Desktop SEM Imaging and Analysis Fast. Outstanding. Reliable SEM imaging and analysis. The Phenom: World s Fastest Scanning Electron Microscope With its market-leading Phenom desktop Scanning

More information

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE CLARIFICATION ON TENDER NUMBER - IISER-PUR-1927-16 ITEM DESCRIPTION- PROCUREMENT OF SCANNING ELECTROCHEMICAL MIRCOSCOPY (SECM) SET UP Refer our Press

More information

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

NanoFocus Inc. Next Generation Scanning Probe Technology.  Tel : Fax: NanoFocus Inc. Next Generation Scanning Probe Technology www.nanofocus.kr Tel : 82-2-864-3955 Fax: 82-2-864-3956 Albatross SPM is Multi functional research grade system Flexure scanner and closed-loop

More information

Scanning Tunneling Microscopy

Scanning Tunneling Microscopy EMSE-515 02 Scanning Tunneling Microscopy EMSE-515 F. Ernst 1 Scanning Tunneling Microscope: Working Principle 2 Scanning Tunneling Microscope: Construction Principle 1 sample 2 sample holder 3 clamps

More information

Basic P-XRD instructions for Operating the Instrument

Basic P-XRD instructions for Operating the Instrument Basic P-XRD instructions for Operating the Instrument Instrument Parts Incident Beam Optics (left arm) 1) X-ray source (Cu) i. Rest settings: 45 kv, 20mA ii. Run settings: 45 kv, 40mA 2) Monochromator

More information

ANNEXURE-I. Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate

ANNEXURE-I. Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate ANNEXURE-I Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate 4 Excise Duty Registration Certificate 5 Pan Card 6 Approved Vendor Certificates

More information

Thin Film Deposition

Thin Film Deposition Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 Crystal s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc.

More information

PROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE

PROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE IFB NO. KGEC/DST-WB/EE /2018-19/995 PROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE Kalyani Government Engineering College Kalyani 741 235; Nadia, West Bengal 1 Government of West Bengal Office of the

More information

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations PAGE 88 & 2008 2007 PRODUCT CATALOG CRYOGENIC PROBE STATION fundamentals...................... 90 principles of cryogenic probe stations attocps I.......................... 92 ultra stable cryogenic probe

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/vecl/Shopping/82

INVITATION FOR QUOTATION. TEQIP-III/2018/vecl/Shopping/82 INVITATION FOR QUOTATION TEQIP-III/2018/vecl/Shopping/82 05-Jul-2018 To,.. Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for

More information

Nanosurf easyscan 2 FlexAFM

Nanosurf easyscan 2 FlexAFM Nanosurf easyscan 2 FlexAFM Your Versatile AFM System for Materials and Life Science www.nanosurf.com The new Nanosurf easyscan 2 FlexAFM scan head makes measurements in liquid as simple as measuring in

More information

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: ) University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: 2012.10.17) The following

More information

Supplementary Figure 1

Supplementary Figure 1 Supplementary Figure 1 Technical overview drawing of the Roadrunner goniometer. The goniometer consists of three main components: an inline sample-viewing microscope, a high-precision scanning unit for

More information

Fabrication and Supply of Cable Tray. CTI Agartala, Aligarh, Gorakhpur, Muzaffarpur, Patna

Fabrication and Supply of Cable Tray. CTI Agartala, Aligarh, Gorakhpur, Muzaffarpur, Patna Fabrication and Supply of Cable Tray at CTI Agartala, Aligarh, Gorakhpur, Muzaffarpur, Patna BROADCAST ENGINEERING CONSULTANTS INDIALIMITED 14-B, I. P. Estate, Ring Road, New Delhi CONTENTS Sr. No Title

More information

Micro-manipulated Cryogenic & Vacuum Probe Systems

Micro-manipulated Cryogenic & Vacuum Probe Systems Janis micro-manipulated probe stations are designed for non-destructive electrical testing using DC, RF, and fiber-optic probes. They are useful in a variety of fields including semiconductors, MEMS, superconductivity,

More information

General Measurement (BB) Part

General Measurement (BB) Part General Measurement (BB) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Setting measurement origin and oscillation/spin conditions... 7 General Measurement (BB)

More information

BL39XU Magnetic Materials

BL39XU Magnetic Materials BL39XU Magnetic Materials BL39XU is an undulator beamline that is dedicated to hard X-ray spectroscopy and diffractometry requiring control of the X-ray polarization state. The major applications of the

More information

Quality Performance, Innovative Design

Quality Performance, Innovative Design Dimensions Confocal Laser Scanning Biological Microscope Table size (mm): 1400(W) 800(D) * Table is not available from Olympus. Avoid placing the controller directly on the floor. Dimensions / Weight /

More information

1) Solar simulator with I-V measurement setup and software

1) Solar simulator with I-V measurement setup and software Department of Optoelectronics, University of Kerala, Kariavattom, Thiruvananthapuram, Kerala, India 695581, Ph: 91 471 2308167 OPTO/Nanophotonics-Phase II/P-1/2014-15 Quotation Notice Quotations are invited

More information

Lesson 2 Diffractometers

Lesson 2 Diffractometers Lesson 2 Diffractometers Nicola Döbelin RMS Foundation, Bettlach, Switzerland January 14 16, 2015, Bern, Switzerland Repetition: Generation of X-rays / Diffraction SEM: BSE detector, BSED / SAED detector

More information

LOW TEMPERATURE STM/AFM

LOW TEMPERATURE STM/AFM * CreaTec STM of Au(111) using a CO-terminated tip, 20mV bias, 0.6nA* LOW TEMPERATURE STM/AFM High end atomic imaging, spectroscopy and manipulation Designed and manufactured in Germany by CreaTec Fischer

More information

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters. TECHNICAL SPECIFICATION FOR PORTABLE ELECTRONIC REFERENCE STANDARD METER (ERS) FOR TESTING OF SINGLE PHASE KILOWATT HOUR ENERGY METERS (ACCURACY CLASS 0. 2) 1. SCOPE: The specification covers the requirement

More information

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research Flexibility Atomic resolution STM image of highly-oriented

More information

Specifications of the Instruments:

Specifications of the Instruments: SHORT QUOTATION NOTICE TU/11-24/Pur/Qtn/2010/ 2148-A, Dt:22/8/11 Sealed Quotations are invited from manufacturer, dealers, etc. for supply of Laboratory equipments for DBT Twinning Project of Professor

More information

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry LECTURE 10 Dr. Teresa D. Golden University of North Texas Department of Chemistry Components for the source include: -Line voltage supply -high-voltage generator -x-ray tube X-ray source requires -high

More information

Ref No: HOlTaarangan/SMS/ /-1763 Date: 16 th Dec, 2013

Ref No: HOlTaarangan/SMS/ /-1763 Date: 16 th Dec, 2013 Taarangan Division, Human Resource Department, Head Office Ref No: HOlTaarangan/SMS/2013-14/-1763 Date: 16 th Dec, 2013 TENDER FOR DESIGNING & PRINTING OF OUR HOUSE JOURNAL "TAARANGAN" Sealed Tenders are

More information

Thin Film Deposition

Thin Film Deposition Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc. 1967 South

More information

Our Company. We are major supplier to:

Our Company. We are major supplier to: VACUUM METROLOGY Our Company Hositrad Holland and Hositrad Deutschland combine more than 50 years of experience in vacuum and cryogenic technology. Customers profit from a broad range of capabilities,

More information

UVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization

UVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization UVISEL Spectroscopic Phase Modulated Ellipsometer The Ideal Tool for Thin Film and Material Characterization High Precision Research Spectroscopic Ellipsometer The UVISEL ellipsometer offers the best combination

More information

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE)

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE) TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE) SPEC NO.: PE-SS-999-145-I009 REV. NO. 01 DATE : 20.04.2012 SHEET 1 OF 4 1.0 SCOPE This specification covers the Design, Manufacture, Inspection and Testing

More information

Introduction of New Products

Introduction of New Products Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can

More information

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: ) University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: 2012.10.17) The following instructions

More information

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications Part I: RF Applications Introductions and Motivations What are RF MEMS? Example Devices RFIC RFIC consists of Active components

More information

Item No.*26 : Lock-in Amplifier

Item No.*26 : Lock-in Amplifier Item No.*26 : Lock-in Amplifier A. AB : Specifications of high frequency DSP lock in amplifier: Signal Channel Voltage input: Single-ended BNC Input impedance: 50Ω or 1 MΩ + 30 pf Damage threshold: ±5

More information

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD Energy < 380 ev Resolution High-Resolution Position Sensitive Detector with Superb Energy Resolution The is the next generation "Compound Silicon Strip" detector with superb energy resolution for ultrafast

More information

TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS)

TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS) TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS) Name of Scope of Work: Paper based Drafting, Designing, Printing, Publication and Supply work (Digital and Offset printing only) TERMS AND CONDITIONS The undersigned

More information

TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS)

TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS) TENDER (OPEN & SHORT TERM TENDER OF 07 DAYS) Name of Scope of Work: Paper based Drafting, Designing, Printing, Publication and Supply work (Digital and Offset printing only) TERMS AND CONDITIONS The undersigned

More information

Manufacturing Metrology Team

Manufacturing Metrology Team The Team has a range of state-of-the-art equipment for the measurement of surface texture and form. We are happy to discuss potential measurement issues and collaborative research Manufacturing Metrology

More information

PRECISION CUTTING MICRACUT 202

PRECISION CUTTING MICRACUT 202 PRECISION CUTTING MICRACUT 202 MICRACUT 202 MICRACUT 202 precision cutters are used for precise and deformation-free cutting of Metals, Ceramics, Electronic Components, Crystals, Composites, Biomaterials,

More information

School of Community Science and Technology Indian Institute of Engineering Science and Technology, Shibpur Howrah

School of Community Science and Technology Indian Institute of Engineering Science and Technology, Shibpur Howrah Indian Institute of Engineering Science and Technology, Shibpur Howrah-711 103 Project Code: DRC/GRSE-OTH/SOCSAT/SKM/002/14-15 Notice Inviting Quotations Sealed quotations are invited for the supply of

More information

When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors.

When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors. When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors. What is greater than God, More evil than the devil, The poor have it, The rich need it, And

More information

Park NX20 The leading nano metrology tool for failure analysis and large sample research.

Park NX20 The leading nano metrology tool for failure analysis and large sample research. The Most Accurate Atomic Force Microscope Park NX20 The leading nano metrology tool for failure analysis and large sample research www.parkafm.com The Most Accurate Atomic Force Microscope Park NX20 The

More information

SCANNING ELECTRON MICROSCOPE (SEM) INSPECTION OF SEMICONDUCTOR DICE. ESCC Basic Specification No

SCANNING ELECTRON MICROSCOPE (SEM) INSPECTION OF SEMICONDUCTOR DICE. ESCC Basic Specification No Page 1 of 24 SCANNING ELECTRON MICROSCOPE (SEM) INSPECTION OF SEMICONDUCTOR DICE ESCC Basic Specification Issue 2 February 2014 Document Custodian: European Space Agency see https://escies.org PAGE 2 LEGAL

More information

Options and Accessories for Asylum Research MFP-3D AFMs

Options and Accessories for Asylum Research MFP-3D AFMs ACCESSORIES Options and Accessories for Asylum Research MFP-3D AFMs Empower your research with powerful, innovative new capabilities Go beyond topography with advanced modes and environmental control Powerful

More information

UNIVERSITY OF ENGINEERING AND TECHNOLOGY, TAXILA (PROCUREMENT CELL)

UNIVERSITY OF ENGINEERING AND TECHNOLOGY, TAXILA (PROCUREMENT CELL) UNIVERSITY OF ENGINEERING AND TECHNOLOGY, TAXILA (PROCUREMENT CELL) SCHEDULE OF REQUIREMENTS FOR PURCHASE OF PURCHASE OF FURNITURE FOR VARIOUS OFFICES The delivery of services and supply will be made in

More information

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right Quick Guide to Operating FEI Titan Themis G2 200 (S)TEM: TEM mode Susheng Tan Nanoscale Fabrication and Characterization Facility, University of Pittsburgh Office: M104/B01 Benedum Hall, 412-383-5978,

More information

ODISHA CONSTRUCTION CORPORATION LTD. (A GOVT. OF ODISHA UNDERTAKING) CENTRAL WORKSHOP,RASULGARH, BHUBANESWAR (ODISHA)

ODISHA CONSTRUCTION CORPORATION LTD. (A GOVT. OF ODISHA UNDERTAKING) CENTRAL WORKSHOP,RASULGARH, BHUBANESWAR (ODISHA) ODISHA CONSTRUCTION CORPORATION LTD. (A GOVT. OF ODISHA UNDERTAKING) CENTRAL WORKSHOP,RASULGARH, BHUBANESWAR-751010 (ODISHA) TENDER DOCUMENT FOR SUPPLY OF HEX HEAD BOLT, NUT, SCREW, WASHER, CONICAL HEAD

More information

INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING)

INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING) INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING) Subject: Request for Uploading the Tender Document on institute web site. Enquiry NO: PM/NET-ME/2013-2014-06 closing date: 27th

More information

H.O-Civil- T&E E-3 /04/2011 / Date QUOTATION CALL NOTICE

H.O-Civil- T&E E-3 /04/2011 / Date QUOTATION CALL NOTICE Orissa Industrial Infrastructure Development Corporation (A Government of Orissa Undertaking) IDCO Towers, Jan path, Bhubaneswar - 751022, Orissa, India Phones: (0674) 2542784, 2540820,Fax: 542 956 Email:

More information

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage

More information

National Science Foundation Center for Lasers and Plasmas for Advanced Manufacturing. Mool C. Gupta Applied Research Center Old Dominion University

National Science Foundation Center for Lasers and Plasmas for Advanced Manufacturing. Mool C. Gupta Applied Research Center Old Dominion University National Science Foundation Center for Lasers and Plasmas for Advanced Manufacturing Mool C. Gupta Applied Research Center Old Dominion University National Science Foundation Center - Center Mission -

More information

Fast Laser Raman Microscope RAMAN

Fast Laser Raman Microscope RAMAN Fast Laser Raman Microscope RAMAN - 11 www.nanophoton.jp Fast Raman Imaging A New Generation of Raman Microscope RAMAN-11 developed by Nanophoton was created by combining confocal laser microscope technology

More information

Tender Specification for Electrochemical Workstation(Bipotentiostat/Galvanostat) Total approximate cost 0.22 crores INR

Tender Specification for Electrochemical Workstation(Bipotentiostat/Galvanostat) Total approximate cost 0.22 crores INR Tender Specification for Electrochemical Workstation(Bipotentiostat/Galvanostat) Total approximate cost 0.22 crores INR Potentiostat Electrode configuration system: Four Maximum potential: ±10 V Maximum

More information

POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME

POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME Field of the Invention The present invention relates to a polymer microstructure. In particular, the present invention

More information

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. : Section : 0 Document : DQM-01 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Section I(B)-Technical Specification Tender Enquery No PUR/UARC-02/14-15 Name of the Equipment: Damped Oscillatory

More information

NOTICE TO BIDDERS PURCHASE OF PORTABLE FORENSIC LASER SCANNING TECHONOLGY

NOTICE TO BIDDERS PURCHASE OF PORTABLE FORENSIC LASER SCANNING TECHONOLGY NOTICE TO BIDDERS Sealed bids will be received by the City of Midwest City at its City Clerk' s office located in the Municipal Building, 100 N. Midwest Blvd., Midwest City, Oklahoma until 2: 00 p. m.,

More information

INSTRUCTION FOR BIDDERS FOR PROVIDING ARCHITECTURAL CONSULTANCY SERVICES FOR THE UPGRADATION OF A GOVERNMENT HOSPITAL IN KERALA

INSTRUCTION FOR BIDDERS FOR PROVIDING ARCHITECTURAL CONSULTANCY SERVICES FOR THE UPGRADATION OF A GOVERNMENT HOSPITAL IN KERALA INSTRUCTION FOR BIDDERS FOR PROVIDING ARCHITECTURAL CONSULTANCY SERVICES FOR THE UPGRADATION OF A GOVERNMENT HOSPITAL IN KERALA JANUARY 2019 HITES (A FULLY OWNED SUBSIDIARY OF HLL LIFECARE LTD, A GOVERNMENT

More information

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Partial Replication of Storms/Scanlan Glow Discharge Radiation Partial Replication of Storms/Scanlan Glow Discharge Radiation Rick Cantwell and Matt McConnell Coolescence, LLC March 2008 Introduction The Storms/Scanlan paper 1 presented at the 8 th international workshop

More information

Length section: New calibration and research services

Length section: New calibration and research services Length section: New calibration and research services O Kruger October 2015 T026 Overview Traditional traceability chart Traceability chart with length R&D projects Overview of Various R&D projects Conclusion

More information

Park XE7 The most affordable research grade AFM with flexible sample handling.

Park XE7 The most affordable research grade AFM with flexible sample handling. Park XE7 The most affordable research grade AFM with flexible sample handling www.parkafm.com Park Systems The Most Accurate Atomic Force Microscope Park XE7 The economical choice for innovative research

More information

X-Ray Spectroscopy with a CCD Detector. Application Note

X-Ray Spectroscopy with a CCD Detector. Application Note X-Ray Spectroscopy with a CCD Detector In addition to providing X-ray imaging solutions, including CCD-based cameras that image X-rays using either direct detection (0.5-20 kev) or indirectly using a scintillation

More information

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA) Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA) This operating procedure intends to provide guidance for general measurements with the AFM. For more advanced measurements or measurements with

More information

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions More information using less radiation Medical Small Animal Security NDE/NDT Diffraction-Enhanced X-ray Imaging Medical Solutions Safe non-invasive

More information

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

UV / VIS Spectrophotometer EMCLAB Instruments GmbH A Professional Manufacturer UV / VIS Spectrophotometer EMCLAB Instruments GmbH EMCLAB Instruments GmbH Bismarckstrasse 120 47057 Duisburg Germany Phone: +49 203 3064042 Fax: +49 203 3064044 E-mail: info@emc-lab.de

More information