Recent ground vibration measurements at CERN (Surface and underground)

Size: px
Start display at page:

Download "Recent ground vibration measurements at CERN (Surface and underground)"

Transcription

1 Recent ground vibration measurements at CERN (Surface and underground) Comparison with other measurements and overview methods K.Artoos, M. Guinchard 16 th October 2008, CLIC workshop

2 Contents : Overview references Ground Vibration measurements CERN measurements in LHC tunnel + surface Power Spectrum Density Integrated RMS + RMS histogram Coherence Conclusions More information: y

3 list of references (> # 60) Methods: V. Shiltsev, A. Sery et al., now INP S. Takeda et al. KEK 1994-now + other Japanese institutes References ground vibration measurements Available on new website stability/ground%20vibration%20studies.htm Absolute measurements : Seismometers, accelerometers, tilt gauges This talk Relative measurements : WPS, HLS, LASER Closed Orbit Distortion measurements Modified SM-3KV 8E4 Vs/m Hz STS-2 2*750 Vs/m120s- 50 Hz tilt meter, HLS 12 bit ADC 16 bit ADC 64 averages, blocks 1 minute at 1 khz Synchronisation: Electrical start trigger (~ ms) Synchronisation LON Network R. Amirikas, A. CMG-3TD, CMG-6TD, 24 1 minute blocks, GPS UTC time Bertolini et al. DESY Digital 24 bit, 360,60s - 80 Hz 2*750Vs/m 200 Hz down sampling bit minimum 15 minutes averaging USGS, CEA,... Specialised Geological survey CLIC, NSLS II, DIAMOND, XFEL,...

4 Set-up measurements at CERN : Guralp CMG 40T x,y,z 2*800Vs/m 1 km of optical Parameters fibre for synchronisation + Sampling rate 2 Muller-BBM timing 256 Hz MKII Analyzers and ddata Transfer Block duration 64 s Average Lin 50 Overlap 66.7 % 30 s -50 Hz ENDEVCO 86 PCB 393B31 Special credits to B. Bolzon, A. Jeremy! 24 bit on 100 mv Low ADC noise

5 Synchronisation Phase error < 0.01 deg

6 Measurements LHC DCUM 1000 ~ 80 m under ground LHC systems in operation, night time Floor building 180 Building 180 Surface No technical systems in operation, night time Measurements Combiner ring CTF 3 Measurements Combiner ring CTF 3 Some technical systems in operation, day time

7 Power Spectrum Density Guralp Endevco m/s m/s^2 2 (1 σ ( f )) DSP DSP σ 1 2 Noise (error) estimation by corrected difference 40 Hz

8 Power Spectrum Density: LHC Tunnel Vertical Technical gallery ATLAS ATL law

9 Power Spectral Density

10 Power Spectral Density A. Sery et al S. Takeda et al STS-2

11 k 2 Integrated R.M.S. LHC Tunnel RMSint ( k) = DSP( k). Δf g k 1 1 nm

12 Integrated R.M.S. 1nm

13 1 nm KEK 2008 A. Sery et al Hz 1 nm 1 nm 50 Hz

14 Example influence ventilation CLEX

15 Averaging, window, histogram, color map 50 averages of 64 sec blocks with 66.7% overlap: To have a good frequency resolution + definition of PSD To see something within the noise But: it s an average view Histogram Baklakov, Shiltsev et al. Fermilab 1997 R.Amirikas, A. Bertolini DESY 2005

16 Color map

17 Color map

18 Coherence measurements Guralp Regression and interpolation analyser software PAK

19 Coherence measurements LHC tunnel 10m 7m 6m 0

20 Coherence measurements Surface Building 180

21 What can influence coherence measurements? Phase shift Amplitude? Low signal to noise ratio micro seismic

22 Joints between concrete modules S. Takeda et al. 1996

23 Coherence: Comparison other measurements SM-3KV A. Sery, Coosemans 1994 LEP

24 Coherence: Comparison other measurements DESY

25 Conclusions Ground vibration level between 1 and 10 nm average integrated RMS at 1 Hz seems possible. Possible vibration sources like water cooling and ventilation should be carefully designed. Support or objects can amplify the ground vibration levels The ground vibration level can be increased by the resonance of a support or object For frequencies > 1Hz, coherence drops over a short distance It is possible to measure (averaged) nanometre displacements with seismometers but some characterisation of devices and analysis methods is still needed. S i i h b i l i i Seismometers with better signal to noise ratio are needed for active control purposes.

26 Spares

27 m/s 500E-9 Channel Guralp_01_EW Throughput Channel Guralp_01_NS Throughput Channel Guralp_01_V Throughput 400E-9 m/s 500E-9 Channel Guralp_02_V Throughput Channel Guralp_02_NS Throughput Channel Guralp_02_EW Throughput 400E-9 300E-9 300E-9 200E-9 200E-9 100E-9 100E-9 0E+0 0E+0-100E-9-100E-9-200E-9-200E-9-300E-9-300E-9-400E-9-400E-9-500E-9-500E s s

GROUND MOTION IN THE INTERACTION. ensured that the final focus quadrupoles on both. rms amplitudes higher than some fraction of the

GROUND MOTION IN THE INTERACTION. ensured that the final focus quadrupoles on both. rms amplitudes higher than some fraction of the GROUND MOTION IN THE INTERACTION REGION C.Montag, DESY Abstract Ground motion and according quadrupole vibration is of great importance for all Linear Collider schemes currently under study, since these

More information

Vibration studies of a superconducting accelerating

Vibration studies of a superconducting accelerating Vibration studies of a superconducting accelerating module at room temperature and at 4.5 K Ramila Amirikas, Alessandro Bertolini, Wilhelm Bialowons Vibration studies on a Type III cryomodule at room temperature

More information

ANALYSIS OF 3RD OCTAVE BAND GROUND MOTIONS TRANSMISSION IN SYNCHROTRON RADIATION FACILITY SOLARIS Daniel Ziemianski, Marek Kozien

ANALYSIS OF 3RD OCTAVE BAND GROUND MOTIONS TRANSMISSION IN SYNCHROTRON RADIATION FACILITY SOLARIS Daniel Ziemianski, Marek Kozien ANALYSIS OF 3RD OCTAVE BAND GROUND MOTIONS TRANSMISSION IN SYNCHROTRON RADIATION FACILITY SOLARIS Daniel Ziemianski, Marek Kozien Cracow University of Technology, Institute of Applied Mechanics, al. Jana

More information

Active Stabilization of a Mechanical Structure

Active Stabilization of a Mechanical Structure Active Stabilization of a Mechanical Structure L. Brunetti 1, N. Geffroy 1, B. Bolzon 1, A. Jeremie 1, J. Lottin 2, B. Caron 2, R. Oroz 2 1- Laboratoire d Annecy-le-Vieux de Physique des Particules LAPP-IN2P3-CNRS-Université

More information

Strong Motion Data: Structures

Strong Motion Data: Structures Strong Motion Data: Structures Adam Pascale Chief Technology Officer, Seismology Research Centre a division of ESS Earth Sciences Treasurer, Australian Earthquake Engineering Society Why monitor buildings?

More information

VIBRATION MEASUREMENTS IN THE KEKB TUNNEL. Mika Masuzawa, Yasunobu Ohsawa, Ryuhei Sugahara and Hiroshi Yamaoka. KEK, OHO 1-1 Tsukuba, Japan

VIBRATION MEASUREMENTS IN THE KEKB TUNNEL. Mika Masuzawa, Yasunobu Ohsawa, Ryuhei Sugahara and Hiroshi Yamaoka. KEK, OHO 1-1 Tsukuba, Japan IWAA2004, CERN, Geneva, 4-7 October 2004 VIBRATION MEASUREMENTS IN THE KEKB TUNNEL Mika Masuzawa, Yasunobu Ohsawa, Ryuhei Sugahara and Hiroshi Yamaoka KEK, OHO 1-1 Tsukuba, Japan 1. INTRODUCTION KEKB is

More information

Results of Vibration Study for LCLS-II Construction in the Research Yard 1

Results of Vibration Study for LCLS-II Construction in the Research Yard 1 LCLS-TN-13-6 Results of Vibration Study for LCLS-II Construction in the Research Yard 1 Georg Gassner SLAC April 16, 2013 Abstract To study the influence of LCLS-II construction on the stability of the

More information

LCLS-II TN Vibration measurements across the SLAC site

LCLS-II TN Vibration measurements across the SLAC site LCLS-II TN Vibration measurements across the SLAC site LCLS-II TN-15-35 9/25/2015 Georg Gassner September 25, 2015 LCLSII-TN-XXXX L C L S - I I T E C H N I C A L N O T E 1 Introduction This document collects

More information

Proposal of test setup

Proposal of test setup Proposal of test setup Status of the study The Compact Linear collider (CLIC) study is a site independent feasibility study aiming at the development of a realistic technology at an affordable cost for

More information

Fast Kickers at DESY

Fast Kickers at DESY Fast Kickers at DESY Injection / ejection in a TESLA like DR Generation of a pulse with a pulse length of 12ns Measurement at TTF 2 Full power test Measurements at ATF XFEL activity Talk given by Hans

More information

Response spectrum Time history Power Spectral Density, PSD

Response spectrum Time history Power Spectral Density, PSD A description is given of one way to implement an earthquake test where the test severities are specified by time histories. The test is done by using a biaxial computer aided servohydraulic test rig.

More information

STRETCHED WIRE OFFSET MEASUREMENTS: 40 YEARS OF PRACTICE OF THIS TECHNIQUE AT CERN

STRETCHED WIRE OFFSET MEASUREMENTS: 40 YEARS OF PRACTICE OF THIS TECHNIQUE AT CERN STRETCHED WIRE OFFSET MEASUREMENTS: 40 YEARS OF PRACTICE OF THIS TECHNIQUE AT CERN Hélène Mainaud Durand, Jean-Pierre Quesnel, Thomas Touzé, CERN The principle Some applications in the existing machines

More information

Welcome Address to the ICFA Nanobeam 2002 Workshop

Welcome Address to the ICFA Nanobeam 2002 Workshop Welcome Address to the ICFA Nanobeam 2002 Workshop Prof. Luciano Maiani Director General CERN 26th Advanced ICFA Beam Dynamics Workshop on Nanometre-Size Colliding Beams Lausanne, 2-6 September 2002 ICFA,

More information

TitleApplication of MEMS accelerometer t. AIZAWA, Takao; KIMURA, Toshinori; M Toshifumi; TAKEDA, Tetsuya; ASANO,

TitleApplication of MEMS accelerometer t. AIZAWA, Takao; KIMURA, Toshinori; M Toshifumi; TAKEDA, Tetsuya; ASANO, TitleApplication of MEMS accelerometer t Author(s) AIZAWA, Takao; KIMURA, Toshinori; M Toshifumi; TAKEDA, Tetsuya; ASANO, Citation International Journal of the JCRM ( Issue Date 2008-12 URL http://hdl.handle.net/2433/85166

More information

Improved Low Frequency Performance of a Geophone. S32A-19 AGU Spring 98

Improved Low Frequency Performance of a Geophone. S32A-19 AGU Spring 98 Improved Low Frequency Performance of a Geophone S32A-19 1 Aaron Barzilai 1, Tom VanZandt 2, Tom Pike 2, Steve Manion 2, Tom Kenny 1 1 Dept. of Mechanical Engineering Stanford University 2 Center for Space

More information

SOLEIL Libera Performance

SOLEIL Libera Performance SOLEIL Libera Performance Libera Workshop 24/25 September 2007 on behalf of the SOLEIL BPM team BPM system: MAC2 requirements, Feb. 2002 closed orbit Correction number of BPMs 120 instead of 112 single

More information

Evaluation of the Refraction Technology RT130HR Remote Seismic System For IRIS/GSN

Evaluation of the Refraction Technology RT130HR Remote Seismic System For IRIS/GSN PROGRESS REPORT June 6, 2006 Ground-based Monitoring R and E Technology Report Evaluation of the Refraction Technology RT130HR Remote Seismic System For IRIS/GSN RT130HR/GainX1 Configuration Richard P.

More information

Laboratory Report INFN Milano LASA

Laboratory Report INFN Milano LASA Laboratory Report INFN Milano LASA Activities Underway Wire Position Monitor: new generation WPMs mounted on cryomodule and readout connected to control system Piezo Vibration Control: microphonic control

More information

Methods for reducing unwanted noise (and increasing signal) in passive seismic surveys

Methods for reducing unwanted noise (and increasing signal) in passive seismic surveys Methods for reducing unwanted noise (and increasing signal) in passive seismic surveys Tim Dean* Aidan Shem Mus ab Al Hasani Curtin University Curtin University Curtin University Bentley, West Australia

More information

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor Development of a Low Cost 3x3 Coupler Mach-Zehnder Interferometric Optical Fibre Vibration Sensor Kai Tai Wan Department of Mechanical, Aerospace and Civil Engineering, Brunel University London, UB8 3PH,

More information

Observations of the OSOP Sixaola, March 1-3, 2016, at the Albuquerque Seismological Laboratory

Observations of the OSOP Sixaola, March 1-3, 2016, at the Albuquerque Seismological Laboratory Observations of the OSOP Sixaola, March 1-3, 2016, at the Albuquerque Seismological Laboratory There were two representatives (Angel Rodriquez and David Nelson) from OSOP at ASL March 1-3, 2016, and they

More information

Analysis of Electrical Noise in Piezoelectric Sensors

Analysis of Electrical Noise in Piezoelectric Sensors Analysis of Electrical Noise in Piezoelectric Sensors Jeffrey Dosch Bill Hynd PCB Piezotronics, Depew NY IMAC XXV February 19-22, 2007 Orlando FL What is noise? Noise is any undesired signal. Electrical

More information

Reference Sources. Prelab. Proakis chapter 7.4.1, equations to as attached

Reference Sources. Prelab. Proakis chapter 7.4.1, equations to as attached Purpose The purpose of the lab is to demonstrate the signal analysis capabilities of Matlab. The oscilloscope will be used as an A/D converter to capture several signals we have examined in previous labs.

More information

Part 2: Second order systems: cantilever response

Part 2: Second order systems: cantilever response - cantilever response slide 1 Part 2: Second order systems: cantilever response Goals: Understand the behavior and how to characterize second order measurement systems Learn how to operate: function generator,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 21-23 Campus Road Contact: Mr K G Dove Listerhills Science Park Tel: +44 (0)1274 393857 Bradford Fax: +44 (0)1274 393336 BD7 1HR E-Mail: sales@otc.co.uk

More information

The VIRGO Environmental Monitoring System

The VIRGO Environmental Monitoring System The VIRGO Environmental Monitoring System R. De Rosa University of Napoli - Federico II and INFN - Napoli Signaux, Bruits, Problèmes Inverses INRA - Nice, 05-05-2008 - Slow Monitoring System - Environmental

More information

Principles of Vibration Measurement and Analysis. Dr. Colin Novak, P.Eng July 29, 2015

Principles of Vibration Measurement and Analysis. Dr. Colin Novak, P.Eng July 29, 2015 Principles of Vibration Measurement and Analysis Dr. Colin Novak, P.Eng. 92-315 July 29, 2015 Vibration Transducers and Signal Conditioning Types of Vibration Transducers The Piezoelectric Accelerometer

More information

SUPERKEKB MAIN RING TUNNEL MOTION

SUPERKEKB MAIN RING TUNNEL MOTION SUPERKEKB MAIN RING TUNNEL MOTION M. Masuzawa, T. Adachi, H. Iinuma, T. Kawamoto and Y. Ohsawa, KEK Tsukuba, Japan Contents Introduction SuperKEKB Main Ring Construction of the new facility buildings &

More information

3 General layout of the XFEL Facility

3 General layout of the XFEL Facility 3 General layout of the XFEL Facility 3.1 Introduction The present chapter provides an overview of the whole European X-Ray Free-Electron Laser (XFEL) Facility layout, enumerating its main components and

More information

ModBox-FE-125ps-10mJ. Performance Highlights FEATURES APPLICATIONS. Electrical & Optical Pulse Diagrams

ModBox-FE-125ps-10mJ. Performance Highlights FEATURES APPLICATIONS. Electrical & Optical Pulse Diagrams The System-FE-1064nm is set to generate short shaped pulses with high extinction ratio at 1064.1 nm. It allows dynamic extinction ratio up to 55 db with user adjustable pulse duration, repetition rate

More information

Magnet Stability (and Reproducibility).

Magnet Stability (and Reproducibility). Magnet Stability (and Reproducibility). Neil Marks, ASTeC, STFC, Daresbury Laboratory, & U. of Liverpool, The Cockcroft Institute, Daresbury, Warrington WA4 4AD, U.K. n.marks@dl.ac.uk With advice and/or

More information

Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at DESY

Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at DESY Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at FLASH @ DESY N. Baboi, DESY, Hamburg for the HOM team : S. Molloy 1, N. Baboi 2, N. Eddy 3, J. Frisch 1, L. Hendrickson

More information

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure Optical Microscope On-axis optical view with max. X magnification Motorized zoom and focus Max Field of view: mm x mm (depends on zoom) Resolution : um Working Distance : mm Magnification : max. X Zoom

More information

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS IWAA2004, CERN, Geneva, 4-7 October 2004 TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS Andreas Herty, Hélène Mainaud-Durand, Antonio Marin CERN, TS/SU/MTI, 1211 Geneva 23, Switzerland 1. ABSTRACT

More information

Thickness Measurement with Laser Displacement Sensors

Thickness Measurement with Laser Displacement Sensors Thickness Measurement with Laser Displacement Sensors Laser displacement sensors are often used for measuring distance, movement and dimensions. If the measured values from two sensors are evaluated together,

More information

ATLAS Phase-II Upgrade Pixel Data Transmission Development

ATLAS Phase-II Upgrade Pixel Data Transmission Development ATLAS Phase-II Upgrade Pixel Data Transmission Development, on behalf of the ATLAS ITk project Physics Department and Santa Cruz Institute for Particle Physics, University of California, Santa Cruz 95064

More information

Vibration Transducer Calibration System

Vibration Transducer Calibration System 1 Overview UCON is designed for calibrating sensitivity, frequency response characteristic and amplitude linearity of acceleration transducer. There are three basic operation modes for the calibration

More information

Microtremor Array Measurements and Three-component Microtremor Measurements in San Francisco Bay Area

Microtremor Array Measurements and Three-component Microtremor Measurements in San Francisco Bay Area Microtremor Array Measurements and Three-component Microtremor Measurements in San Francisco Bay Area K. Hayashi & D. Underwood Geometrics, Inc., United States SUMMARY: Microtremor array measurements and

More information

A compact high precision Fabry-Perot interferometer for monitoring Earth deformation

A compact high precision Fabry-Perot interferometer for monitoring Earth deformation A compact high precision Fabry-Perot interferometer for monitoring Earth deformation Han Cheng SEAT seat@enseeiht.fr M. Cattoen, F. Lizion, O. Bernal G. Ravet, L. Michaut Consortium ANR LINES & FUI MIRZA

More information

Bioimaging of cells and tissues using accelerator-based sources

Bioimaging of cells and tissues using accelerator-based sources Analytical and Bioanalytical Chemistry Electronic Supplementary Material Bioimaging of cells and tissues using accelerator-based sources Cyril Petibois, Mariangela Cestelli Guidi Main features of Free

More information

Panasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD

Panasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD Panasonic, 2 Channel FFT Analyzer VS-3321A DC to 200kHz,512K word memory,and 2sets of FDD New generation 2CH FFT Anal General The FFT analyzer is a realtime signal analyzer using the Fast Fourier Transform

More information

Testing in a Combined Vibration and Acceleration Environment

Testing in a Combined Vibration and Acceleration Environment Testing in a Combined Vibration and Acceleration Environment Richard Jepsen and Edward Romero Mechanical Environments Department, MS 1135 Sandia National Laboratories, PO Box 5800 Albuquerque, NM 87185

More information

Session 3 Summary: Orbit Feedback

Session 3 Summary: Orbit Feedback Session 3 Summary: Orbit Feedback Workshop on Ambient Ground Motion and Vibration Suppression for Low Emittance Storage Rings GM2017 12/13/2017 MMS System Design, Initial Results and Experiments with Orbit

More information

Characterisation of SiPM Index :

Characterisation of SiPM Index : Characterisation of SiPM --------------------------------------------------------------------------------------------Index : 1. Basics of SiPM* 2. SiPM module 3. Working principle 4. Experimental setup

More information

A 4 Channel Waveform Sampling ASIC in 130 nm CMOS

A 4 Channel Waveform Sampling ASIC in 130 nm CMOS A 4 Channel Waveform Sampling ASIC in 130 nm CMOS E. Oberla, H. Grabas, J.F. Genat, H. Frisch Enrico Fermi Institute, University of Chicago K. Nishimura, G. Varner University of Hawai I Large Area Picosecond

More information

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. 295 ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. CERN, CH-1211 Geneva 23, Switzerland Introduction Electromagnets

More information

Metrology for QKD an industrial quantum optical communication technology

Metrology for QKD an industrial quantum optical communication technology Metrology for QKD an industrial quantum optical communication technology Christopher Chunnilall christopher.chunnilall@npl.co.uk 1 st ETSI Quantum-Safe-Crypto-Workshop Sophia-Antipolis, France 26-27 September

More information

Technology Days GSFC Optics Technologies. Dr. Petar Arsenovic

Technology Days GSFC Optics Technologies. Dr. Petar Arsenovic Technology Days 2011 GSFC Optics Technologies Dr. Petar Arsenovic Optics Capabilities Optical Design and Analysis Opto-mechanical Design and Fabrication Materials and Thin Films Component Development and

More information

FAST RF KICKER DESIGN

FAST RF KICKER DESIGN FAST RF KICKER DESIGN David Alesini LNF-INFN, Frascati, Rome, Italy ICFA Mini-Workshop on Deflecting/Crabbing Cavity Applications in Accelerators, Shanghai, April 23-25, 2008 FAST STRIPLINE INJECTION KICKERS

More information

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC Roman Pots Marco Oriunno SLAC, PPA The Roman Pot technique 1. The Roman Pot, an historically successful technique for near beam physics: ISR, SPS, TEVATRON, RICH, DESY 2. A CERN in-house technology: ISR,

More information

Diamond sensors as beam conditions monitors in CMS and LHC

Diamond sensors as beam conditions monitors in CMS and LHC Diamond sensors as beam conditions monitors in CMS and LHC Maria Hempel DESY Zeuthen & BTU Cottbus on behalf of the BRM-CMS and CMS-DESY groups GSI Darmstadt, 11th - 13th December 2011 Outline 1. Description

More information

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW CW 660nm laser Extremely low noise Power 500mW TECHNICAL DATA SHEET The high specification 660nm laser Overview The at 660nm and 500mW is among the most powerful and compact red lasers available today

More information

SC11 Compact Analysis System

SC11 Compact Analysis System SPICER CONSULTING SC11/Compact SC11 Compact Analysis System SC11 System in carrying case Windows laptop powered measurement and analysis system Data acquired and pre-processed in sensor with universal

More information

Drive Beam Photo-injector Option for the CTF3 Nominal Phase

Drive Beam Photo-injector Option for the CTF3 Nominal Phase CTF3 Review Drive Beam Photo-injector Option for the CTF3 Nominal Phase Motivation CTF3 Drive Beam Requirements CTF3 RF gun design The Laser (I. Ross / RAL) The Photocathode Cost estimate Possible schedule

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration, Inc. 1 Industrial

More information

Adaptive Optics for LIGO

Adaptive Optics for LIGO Adaptive Optics for LIGO Justin Mansell Ginzton Laboratory LIGO-G990022-39-M Motivation Wavefront Sensor Outline Characterization Enhancements Modeling Projections Adaptive Optics Results Effects of Thermal

More information

Physics Spring 2006 Experiment 9 TRAVELING WAVES

Physics Spring 2006 Experiment 9 TRAVELING WAVES Physics 31210 Spring 2006 Experiment 9 TRAVELING WAVES Reference: Halliday, Resnick & Walker, 7th Ed., Sections 16-1 to 5, Sections 17-1 to 4 I. Introduction: Waves of all kinds, propagating through many

More information

A 4-Channel Fast Waveform Sampling ASIC in 130 nm CMOS

A 4-Channel Fast Waveform Sampling ASIC in 130 nm CMOS A 4-Channel Fast Waveform Sampling ASIC in 130 nm CMOS E. Oberla, H. Grabas, M. Bogdan, J.F. Genat, H. Frisch Enrico Fermi Institute, University of Chicago K. Nishimura, G. Varner University of Hawai I

More information

Overview of enhancement cavity work at LAL

Overview of enhancement cavity work at LAL Overview of enhancement cavity work at LAL INTRO: Optical cavity developments at LAL Compton scattering Results on optical cavity in picosecond regime Polarised positron source R&D effort Developments

More information

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine A description is given of one way to implement an earthquake test where the test severities are specified by the sine-beat method. The test is done by using a biaxial computer aided servohydraulic test

More information

Sub-nanometer active seismic isolator control

Sub-nanometer active seismic isolator control Review Article Sub-nanometer active seismic isolator control Journal of Intelligent Material Systems and Structures 24(15) 1785 1795 Ó The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalspermissions.nav

More information

Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements

Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements Our thanks to Agilent Technologies for allowing us to reprint this article. Introduction Finding a cost-effective power source

More information

3D Distortion Measurement (DIS)

3D Distortion Measurement (DIS) 3D Distortion Measurement (DIS) Module of the R&D SYSTEM S4 FEATURES Voltage and frequency sweep Steady-state measurement Single-tone or two-tone excitation signal DC-component, magnitude and phase of

More information

Overview of performance and improvements to fixed exit double crystal monochromators at Diamond. Andrew Dent, Physical Science Coordinator, DLS

Overview of performance and improvements to fixed exit double crystal monochromators at Diamond. Andrew Dent, Physical Science Coordinator, DLS Overview of performance and improvements to fixed exit double crystal monochromators at Diamond Andrew Dent, Physical Science Coordinator, DLS Overview Diffraction limit Geometric magnification Source

More information

CASE STUDY BRIDGE DYNAMIC MONITORING

CASE STUDY BRIDGE DYNAMIC MONITORING Introduction BRIDGE DYNAMIC MONITORING Monitoring of structure movements and vibrations (bridges, buildings, monuments, towers etc.) is an increasingly important task for today s construction engineers.

More information

VARIABLE REPETITION RATE THOMSON SCATTERING SYSTEM FOR THE GLOBUS-M TOKAMAK

VARIABLE REPETITION RATE THOMSON SCATTERING SYSTEM FOR THE GLOBUS-M TOKAMAK VARIABLE REPETITION RATE THOMSON SCATTERING SYSTEM FOR THE GLOBUS-M TOKAMAK S.Yu.Tolstyakov, V.K.Gusev, M.M.Kochergin, G.S.Kurskiev, E.E.Mukhin, Yu.V.Petrov, G.T.Razdobarin A.F. Ioffe Physico-Technical

More information

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration ATLAS Muon Trigger and Readout Considerations Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration ECFA High Luminosity LHC Experiments Workshop - 2016 ATLAS Muon System Overview

More information

Novel piezoresistive e-nose sensor array cell

Novel piezoresistive e-nose sensor array cell 4M2007 Conference on Multi-Material Micro Manufacture 3-5 October 2007 Borovets Bulgaria Novel piezoresistive e-nose sensor array cell V.Stavrov a, P.Vitanov b, E.Tomerov a, E.Goranova b, G.Stavreva a

More information

Electro-Optical Measurements at the Swiss Light Source (SLS) Linac at the PSI. First Results

Electro-Optical Measurements at the Swiss Light Source (SLS) Linac at the PSI. First Results Electro-Optical Measurements at the Swiss Light Source (SLS) Linac at the PSI First Results Overview motivation electro-optical sampling general remarks experimental setup synchronisation between TiSa-laser

More information

INTERFEROMETRIC VIBRATION DISPLACEMENT MEASUREMENT

INTERFEROMETRIC VIBRATION DISPLACEMENT MEASUREMENT Romanian Reports in Physics, Vol. 62, No. 3, P. 671 677, 2010 Dedicated to the 50 th LASER Anniversary (LASERFEST-50) INTERFEROMETRIC VIBRATION DISPLACEMENT MEASUREMENT F. GAROI 1, P.C. LOGOFATU 1, D.

More information

Spatial coherency of earthquake-induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network

Spatial coherency of earthquake-induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network Spatial coherency of -induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network Ebru Harmandar, Eser Cakti, Mustafa Erdik Kandilli Observatory and Earthquake Research Institute,

More information

A high resolution bunch arrival time monitor system for FLASH / XFEL

A high resolution bunch arrival time monitor system for FLASH / XFEL A high resolution bunch arrival time monitor system for FLASH / XFEL K. Hacker, F. Löhl, F. Ludwig, K.H. Matthiesen, H. Schlarb, B. Schmidt, A. Winter October 24 th Principle of the arrival time detection

More information

Gain and Breakdown Voltage Measurements

Gain and Breakdown Voltage Measurements Gain and Breakdown Voltage Measurements CLICdp: ECAL Lab Meeting (CERN) Magdalena Munker March 2, 215 Setup for study of Scintillator tiles with SiPM Readout Setup in cooled dark room ( temperature about

More information

SPEEDBOX Technical Datasheet

SPEEDBOX Technical Datasheet SPEEDBOX Technical Datasheet Race Technology Limited, 2008 Version 1.1 1. Introduction... 3 1.1. Product Overview... 3 1.2. Applications... 3 1.3. Standard Features... 3 2. Port / Connector details...

More information

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

SmartSenseCom Introduces Next Generation Seismic Sensor Systems SmartSenseCom Introduces Next Generation Seismic Sensor Systems Summary: SmartSenseCom, Inc. (SSC) has introduced the next generation in seismic sensing technology. SSC s systems use a unique optical sensing

More information

LIGO PROJECT. Piezo-Electric Actuator Initial Performance Tests. Eric Ponslet April 13, Abstract

LIGO PROJECT. Piezo-Electric Actuator Initial Performance Tests. Eric Ponslet April 13, Abstract Piezo-Electric Actuator Initial Performance Tests Eric Ponslet April 13, 1998 Abstract This report briefly describes the setup and results from a series of tests performed on a commercially available piezo-electric

More information

Designing for Femtosecond Pulses

Designing for Femtosecond Pulses Designing for Femtosecond Pulses White Paper PN 200-1100-00 Revision 1.1 July 2013 Calmar Laser, Inc www.calmarlaser.com Overview Calmar s femtosecond laser sources are passively mode-locked fiber lasers.

More information

Nikhef jamboree - Groningen 12 December Atlas upgrade. Hella Snoek for the Atlas group

Nikhef jamboree - Groningen 12 December Atlas upgrade. Hella Snoek for the Atlas group Nikhef jamboree - Groningen 12 December 2016 Atlas upgrade Hella Snoek for the Atlas group 1 2 LHC timeline 2016 2012 Luminosity increases till 2026 to 5-7 times with respect to current lumi Detectors

More information

An Overview of Ground Motion and Vibration Studies

An Overview of Ground Motion and Vibration Studies An Overview of Ground Motion and Vibration Studies 1 Acknowledgements SLAC Accelerator Physics: Andrei Seryi, Fredric Le Pimpec SLAC Conventional Facility: Clay Corvin, Javier Sevilla, Jerry Aarons Colin

More information

Development of the accelerometer for cryogenic experiments II

Development of the accelerometer for cryogenic experiments II Development of the accelerometer for cryogenic experiments II ICRR Univ. of Tokyo, KEK A, Dept. of advanced materials science Univ. of Tokyo B K. Yamamoto, H. Hayakawa, T. Uchiyama, S. Miyoki, H. Ishitsuka,

More information

Magnitude & Intensity

Magnitude & Intensity Magnitude & Intensity Lecture 7 Seismometer, Magnitude & Intensity Vibrations: Simple Harmonic Motion Simplest vibrating system: 2 u( x) 2 + ω u( x) = 0 2 t x Displacement u ω is the angular frequency,

More information

CALICE AHCAL overview

CALICE AHCAL overview International Workshop on the High Energy Circular Electron-Positron Collider in 2018 CALICE AHCAL overview Yong Liu (IHEP), on behalf of the CALICE collaboration Nov. 13, 2018 CALICE-AHCAL Progress, CEPC

More information

Features. Applications. Optional Features

Features. Applications. Optional Features Features Compact, Rugged Design TEM Beam with M 2 < 1.2 Pulse Rates from Single Shot to 15 khz IR, Green, UV, and Deep UV Wavelengths Available RS232 Computer Control Patented Harmonic Generation Technology

More information

Beam Condition Monitors and a Luminometer Based on Diamond Sensors

Beam Condition Monitors and a Luminometer Based on Diamond Sensors Beam Condition Monitors and a Luminometer Based on Diamond Sensors Wolfgang Lange, DESY Zeuthen and CMS BRIL group Beam Condition Monitors and a Luminometer Based on Diamond Sensors INSTR14 in Novosibirsk,

More information

Coherent Synchrotron Radiation in the ANKA Storage Ring

Coherent Synchrotron Radiation in the ANKA Storage Ring Coherent Synchrotron Radiation in the ANKA Storage Ring Marcel Schuh On behalf of the ANKA THz-Group Laboratory for Applications of Synchrotron Radiation (LAS) / Institute of Synchrotron Radiation (ISS)

More information

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface SPECIFICATIONS PXIe-5645 Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface Contents Definitions...2 Conditions... 3 Frequency...4 Frequency Settling Time... 4 Internal Frequency Reference...

More information

WP 6: Validation Studies Vienna Test Case

WP 6: Validation Studies Vienna Test Case Systemic Seismic Vulnerability and Risk Analysis for Buildings, Lifeline Networks and Infrastructures Safety Gain WP 6: Validation Studies Vienna Test Case D. Schäfer, VCE A. Bosi, VCE T. Gruber, VCE H.

More information

TEST EQUIPMENT CO., LTD

TEST EQUIPMENT CO., LTD Electromagnetic Type High Frequency Vibration Tester (ES-3) Technical Specification Index 1 Application...page 2 2 Vibration System...page 2-5 2-1 Technical Parameters 2-2 Vibration Components Details

More information

Structural Health Monitoring of bridges using accelerometers a case study at Apollo Bridge in Bratislava

Structural Health Monitoring of bridges using accelerometers a case study at Apollo Bridge in Bratislava UDC: 531.768 539.38 543.382.42 DOI: 10.14438/gn.2015.03 Typology: 1.01 Original Scientific Article Article info: Received 2015-03-08, Accepted 2015-03-19, Published 2015-04-10 Structural Health Monitoring

More information

MXD6240/6241AU. Autonomous 8-Angle Tip-Over Sensor with High Vibration Immunity

MXD6240/6241AU. Autonomous 8-Angle Tip-Over Sensor with High Vibration Immunity Autonomous 8-Angle Tip-Over Sensor with High Vibration Immunity MXD6240/6241AU FEATURES 8 Pin-programmable angle thresholds Single-wire digital output Fully autonomous- no uc required Built-in self-test

More information

SPREAD SPECTRUM CHANNEL MEASUREMENT INSTRUMENT

SPREAD SPECTRUM CHANNEL MEASUREMENT INSTRUMENT SPACE SPREAD SPECTRUM CHANNEL MEASUREMENT INSTRUMENT Satellite communications, earth observation, navigation and positioning and control stations indracompany.com SSCMI SPREAD SPECTRUM CHANNEL MEASUREMENT

More information

SC11 Analysis System - Sensor Interface

SC11 Analysis System - Sensor Interface SPICER CONSULTING SC11/SI SC11 Analysis System - Sensor Interface SC11 System in case Portable, laptop based, measurement and analysis system Laboratory precision measurements of environmental magnetic

More information

New Long Stroke Vibration Shaker Design using Linear Motor Technology

New Long Stroke Vibration Shaker Design using Linear Motor Technology New Long Stroke Vibration Shaker Design using Linear Motor Technology The Modal Shop, Inc. A PCB Group Company Patrick Timmons Calibration Systems Engineer Mark Schiefer Senior Scientist Long Stroke Shaker

More information

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017 R. J. Jones College of Optical Sciences OPTI 511L Fall 2017 Active Modelocking of a Helium-Neon Laser The generation of short optical pulses is important for a wide variety of applications, from time-resolved

More information

Progress of the TEO experiment at FLASH

Progress of the TEO experiment at FLASH Progress of the TEO experiment at VUV-FEL at DESY - Armin Azima S. Duesterer, J. Feldhaus, H. Schlarb, H. Redlin, B. Steffen, DESY Hamburg K. Sengstock, Uni Hamburg Adrian Cavalieri, David Fritz, David

More information

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination. Name: Number: Department of Mechanical and Aerospace Engineering MAE334 - Introduction to Instrumentation and Computers Final Examination December 12, 2002 Closed Book and Notes 1. Be sure to fill in your

More information

1 Lock-in Amplifier Introduction

1 Lock-in Amplifier Introduction 1 Lock-in Amplifier Introduction The purpose of this laboratory is to introduce the student to the lock-in amplifier. A lock-in amplifier is a nearly ubiquitous piece of laboratory equipment, and can serve

More information

Reference Distribution

Reference Distribution EPAC 08, Genoa, Italy RF Reference Signal Distribution System for FAIR M. Bousonville, GSI, Darmstadt, Germany P. Meissner, Technical University Darmstadt, Germany Dipl.-Ing. Michael Bousonville Page 1

More information

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

MEMS Optical Scanner ECO SCAN Application Notes. Ver.0 MEMS Optical Scanner "ECO SCAN" Application Notes Ver.0 Micro Electro Mechanical Systems Promotion Dept., Visionary Business Center The Nippon Signal Co., Ltd. 1 Preface This document summarizes precautions

More information

Goals of the Lab: Photodetectors and Noise (Part 2) Department of Physics. Slide 1. PHYSICS6770 Laboratory 4

Goals of the Lab: Photodetectors and Noise (Part 2) Department of Physics. Slide 1. PHYSICS6770 Laboratory 4 Slide 1 Goals of the Lab: Understand the origin and properties of thermal noise Understand the origin and properties of optical shot noise In this lab, You will qualitatively and quantitatively determine

More information