Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Size: px
Start display at page:

Download "Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions"

Transcription

1 Digital Counter DIN 7 x 7 mm Counters with Easy-to-use Functions Designed with an emphasis on ease of operation. All models equipped with prescale function which displays in units of actual physical parameters (length, volume, etc.). -C large/small discrimination mode useful for positioning and production control. igh-speed response allows 1, counts per second. igh-visibility CD display with built-in backlight. Online change of set value possible. Meets U and CSA standards. Conforms to EMC standards. Conforms to EN611-1/IEC11-1. Six-language instruction manual provided. 1

2 Ordering Information Counters Standard (with backlight) ±Range type (with backlight) One Stage Two Stages One Stage Two Stages No-voltage Input Voltage No-voltage Input Voltage No-voltage Input Voltage No-voltage Input Voltage External power supply Outputs Control power source 1/4 VDC (switching) [ ma at 1 VDC; 8 ma at 4 VDC] Contact and NPN transistor output 1 to 4 VAC 5/6 z 4 VAC 1 to 4 VDC -B -B -BV -BV -BW -BW -BWV -BWV -C -C -CV -CV -CW -CW -CWV -CWV Contact and PNP transistor output 1 to 4 VAC 5/6 z 4 VAC 1 to 4 VDC -BP -BP -BVP -BWP -BVP -BWP -BWVP -BWVP -CP -CP -CVP -CVP -CWP -CWP -CWVP -CWVP Note: Specify both the model and control power supply when ordering. With shock prevention cover types are named Model egend Type B: Standard C: +/- range. Classification None: 1-stage set counter W: -stage set counter Accessories (Order Separately) Soft Cover/Y9A-7F1 ard Cover/Y9A-7 3. Input Type None: No-voltage V: Voltage 4. Output Type None: NPN output P: PNP output Shock Prevention Cover/Y9A-7T Note: Models with a Shock Prevention Cover can be ordered by adding -5 to the end of the model number. e.g., -B-5 (1 to 4 VAC, 5/6 z)

3 Specifications Classification Mounting method Model -B (Standard type) -C (±Range type) External connections Enclosure ratings Approved standards Input modes* Digital preset counter Flush mounting Screw terminals IP54 (panel surface) U58, CSA C. No.14, conforms to EN611-1/IEC611-1, EN581-, and EN58- Up (Incrementing), Down (decrementing), and reversible Up/Down A (command s), Up/Down B (individual s), Up/Down C (phase difference s) Output modes* N, F, C, R, K, P, Q, A K, D,, system Prescaling function Yes (.1 to ) Decimal point adjustment External, manual and automatic resets (internal according to C, R, P, AND Q mode operation) Yes (Rightmost 3 digits) Teaching function --- Yes Batch counting function Yes --- Set compensation --- Yes Gate power supply Input signals Input method Control outputs Yes 1 VDC/4 VDC (switching) Count, reset, key protection, and gate s Batch count reset Reversible Up/Down A (command s), Up/Down B (individual s), Up/Down C (phase difference s External and manual resets Compensation No-voltage : Via opening and closing of contact Voltage : Via high and low signal voltage (key protection is no-voltage ) 1 stage model: SPST-NO contact and transistor (NPN or PNP open collector) output stage model: stages of SPST-NO contact and transistor (NPN or PNP open collector) output Transistor output can be changed by switch. (Except for batch count output.) Batch outputs Transistor output (NPN or PNP open collector) --- Display CD with backlight Digits 6 digits ( to 999,999) ±6 digits (-999,999 to 999,999) Memory backup Backup time for power interruption: Approx. 1 years at C (lithium battery) 3

4 Ratings Rated supply voltage Operating voltage range 1 to 4 VAC, 5/6 z 4 VAC/1 to 4 VDC (contains % ripple max.) 85% to 11% of rated voltage Current consumption Approx. 1 VA at 5 z, 4 VAC; approx. 6 W at 4 VDC * Max. counting speeds (CP1, CP) Compensation and gate Batch count reset Key protection 3/1k/5k/1 kcps (separate setting for CP1 and CP) Set to the faster of the CP1 and CP max. counting speeds Min. pulse width for external reset: 1 or ms, also manual reset Min. pulse width: Approx. ms Response time: 1 s One-shot time 1, 5, 1,, 5, and 1, ms (separate setting for stages 1 and ) Count, compensation, reset, batch count reset, and gate s Key protection No-voltage ON impedance: 1 kω max. (Approx. ma when kω) ON residual voltage: V max. OFF impedance: 1 kω max. Voltage ( resistance: approx. 4.7 kω) igh level: 4.5 to 3 VDC ow level: to VDC No-voltage ON impedance: 1 kω max. (Approx. ma when kω) ON residual voltage: 1 V max. OFF impedance: 1 kω min. Control outputs Contacts: 3 A at 5 VAC, resistive load (cos φ = 1) Transistor output: Open collector 1mA at 3 VDC max. residual voltage V max. (Approx. 1 V) External power supply ma, 1 VDC ±1% (5% ripple max.) 8 ma, 4 VDC ±1% (5% ripple max.) *When power is turned ON, approx. 8 A inrush current flows for about ms. (4 VDC, 4 VAC) Characteristics Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance 1 MΩ min. (at 5 VDC) (between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts), VAC, 5/6 z for 1 min (between current-carrying terminal and exposed non-current-carrying metal parts) 3 kv (between power terminals) for 1 to 4 VAC type, 1 kv for 4 VAC/1 to 4 VDC 4.5 kv (between current-carrying terminal and exposed non-current-carrying metal parts for 1 to 4 VAC type, 1.5 kv for 4 VAC/1 to 4 VDC. ± kv (between power terminals) and ±6 V (between terminals), square-wave noise by noise simulator (pulse width: 1 ns/1 µs, 1-ns rise) Malfunction: 8 kv; destruction: kv 1 to 55 z with.75-mm single amplitude each in three directions 1 to 55 z with.5-mm single amplitude each in three directions Shock resistance ife expectancy 3 m/s (Approx. 3G) each in three directions 1 m/s (Approx. 1G) each in three directions 1 million operations o min. 1, operations min. 5 A at 5 VAC in load resistance) Weight Ambient temperature Approx. 7 g Operating: 1 C to 55 C (with no icing) Storage: 5 C to 65 C (with no icing) Ambient humidity Operating: 35% to 85% EMC (EMI): EN581- Emission Enclosure: EN5511 Group 1 class A Emission AC Mains: EN5511 Group 1 class A (EMS): EN58- Immunity ESD: Case color EN61-4-:4 kv contact discharge 8 kv air discharge Immunity RF-interference: ENV514: 1 V/m (Amplitude-modulated, 8 Mz to 1 Gz) 1 V/m (Pulse-modulated, 9 Mz) Immunity Conducted Disturbance: ENV5141: 1 V (. to 8 Mz) Immunity Burst: ight gray (Munsell 5Y7/1) EN61-4-4: kv power-line kv I/O signal-line 4

5 Block Diagram CD drive clock generator System clock generator CD reference voltage generator Function setting circuit ROM RAM CD driver CD Key switch circuits Input circuits (CP1, CP, compensation, gate, reset, batch count reset, key protection) Count circuits Control circuits Battery One-chip microcomputer Power outage detector No-contact outputs inverter (DIP switch pins 1,) Output circuits (OUT, batch output) AC (DC) Power circuits * External power supply * Power supply is insulated from I/O. I/O Functions Inputs CP1/CP Count signal s. Up, Down, and Up/Down (command, individual, or phase difference) s accepted. Compensation (±Range type) Batch count reset (Standard type) s present value. (to zero in Up modes, to preset with 1-stage models in Down mode, and to preset with -stage models.) Count s are not accepted while reset is ON. indicator lit while reset is ON. On rising edge of up count signal, present count is reset to compensation value and, therefore, count s are accepted even if the compensation is set to ON (not effective for down count signals.) s batch count to zero and batch output turns OFF. Signals are taken in on the ON edge. Batch count signals are not accepted while batch count reset is ON. Key protection Makes keys inoperative according to key protection level. Key protection indicator lit while key protection is ON. Effective when power supply is turned off. Effective when protect terminals are shorted. Gate Inhibits counter operation when gate is ON. Outputs OUT 1. Outputs made according to designated output mode when corresponding preset is reached. Outputs inhibit on the teaching mode. Batch output (Standard type) Outputs made when batch counter is up to preset number of batches. Batch output remains ON until batch count reset goes ON. When the number of batches is set to zero, batch counting is performed but batch outputs are not made. Batch counter counts the number of completed counts to the preset for 1-stage models amd to preset for -stage models. 5

6 Engineering Data ife Expectancy of Contacts Electrical ife Expectancy (Resistive oad) Electrical ife Expectancy (Inductive oad) No. of operations (x 1 3 ) 5 VAC (cos φ = 1) 3 VDC (cos φ = 1) No. of operations (x 1 3 ) 5 VAC (cos φ =.4) 3 VDC (/R = 7 ms) oad current (A) oad current (A) Reference: A current of. A max. can be switched at 15 VDC (cos φ =1) and a current of.1 A max. can be switched if /R = 7 ms. In both cases, a life of 1, operations can be expected. Nomenclature Front View Indicator 1. Power indicator. Key protection indicator 3. Control output indicator OUT: 1 stage OUT1, OUT: stages 4. Batch output indicator (-B only) 5. Present value (character height: 1mm) (Zeroes suppressed) 6. Set value (character height: 8 mm) (Indicates data in function setting mode) 7. Set value 1, stage indicator. 8. Batch indicator (Displays batch count indicator.) Operation Key 9. Increment Keys (1 to 6) (Used to change the corresponding digit of the set value. Used to change data in the function setting mode.) 1. Code Key (-C type only) (Changes ±code of setting value.) 11. Display Key (Switches to the batch count, teaching mode, setting displays. For stage model, switch set value 1,.) 1. Batch Key (-B type only) (Switches to the batch display.) 13. Teaching Key (-C type only) (Switches to the teaching mode.) 14. Mode Key (Switches from run mode to function setting mode. Changes items in the function setting mode.. Key (s present value and outputs.) 6

7 Side View Dip switch Models One-stage Two-stage Switch No. OFF ON OFF ON Operation of each transistor output when count up OFF to ON ON to OFF Output OFF to ON Output ON to OFF OFF to ON ON to OFF Invalid External power supply 1 VDC 4 VDC 1 VDC 4 VDC Note: All DIP Switches are set to OFF at the factory. Operation Factory Settings The following table shows the timer settings when it is shipped. Please change the settings as necessary to suit the system before operation. Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions. Model -B -C Present value Presets Batch present count --- Batch setting count --- Input mode Up Up/Down C (phase difference) Output mode N K time (old) 1, ms time (-stage only) old 1, ms CP1 and CP counting speeds 3 cps 3 cps Min. reset time ms ms Decimal point Far right (no fractions) Far right (no fractions) Prescale 1, 1, Compensation count value --- Key protection level KP-1 KP-1 Note: With the initial settings, there will be no output even if the power supply is connected. External s and outputs cannot be used without a power supply. 7

8 Operational Overview Run mode Setting mode MODE Key Present value, set value 1 Input mode DISPAY Key DISPAY Key Present value, set value DISPAY Key Output mode MODE Key MODE Key BATC key time Batch count value MODE Key time MODE Key MODE Key TEAC key DISPAY Key CP1 and CP Count speed MODE Key Teaching mode Min. reset time MODE Key Present value Decimal point MODE or TEAC Key Present value, set value 1 MODE or TEAC Key Prescale value MODE Key MODE Key MODE or TEAC Key Compensation count value Present value, set value Key protection level Note: Set values are changed with the Increment Keys (1 to 6). 8

9 Setting Item Table Mode Setting item Applicable model Description Setting procedure e (Display) -B -C Run mode Function setting mode Set value 1 (SET1) Set value (SET) Batch count set value Input mode (IN) Output mode (OUT) Output time 1 (-stage model only) (OUT) CP1 and CP Count speed (CP1, CP) Min. reset time (RST) Decimal point (------) Yes Yes Compared to the present value, determines the timing of the control output according to the output mode. The DISPAY Key switches between set values 1 and. (-stage model only.) Yes No Batch output is turned ON when the set number of times Yes Yes Determines the mode selecting from Up, Down, Up/Down modes. Yes Yes Determines the form of the control output. (Refer to the present value vs. output diagrams on pages to.) Determines the output time for control output (). Yes Yes Determines the output time of the control output (OUT 1) for -stage model counters. Yes Yes Switches the count filter to protect against errant counts due to interference. Yes Yes Determines the initial signal width of the external reset. Yes Yes Determines the decimal point position of the present and set values. Sequence when changing a digit using the Keys (1 to 6).... Code Key (+/ ) to change the plus or minus sign of the set value if the model is the -C. (+) (blank) (-) Sequence when changing a digit using the Keys (1 to 6). is counted.... Press keys 1 to 6 to change the mode. * * (Up) (Down) (Up/Down A) (Up/Down B) (Up/Down C) *-B only. Press keys 1 to 6 to change the mode. -B -C (N) (F) (C) (R) (K) (P) (Q) (A) * (K) (D) () () * -stage model only. Press keys 1 to 6 to change the time. (Applicable to output modes C, R, K, P, Q, and A * only. ms ms ms ms ms ms Press keys 1 to 6 to change the set value. * (self holding) ms ms ms ms ms *-BW only. Press keys 1 to 6 to change the set value. (3cps) (1kcps) (5kcps) (1Kcps) ms The response speeds of the gate and compensation are both set to the count speed of CP1 or CP, whichever is faster. The CP1 and CP count speed must be set to the same value only when the is in Up/Down C mode. Press keys 1 to 6 to change the set value. (1 ms) ( ms) Move the decimal point position with keys, 1 to 6. 9

10 Mode Function setting mode Setting item (Display) Prescale value (PS) Compensation count value (C.C) Key protection level Applicable model -B -C Description Yes Yes Can calculate and display a physical parameter (volume, length, etc.) from the present value. For example, if one count represented a movement of. mm, the prescale value would be.. Values from.1 to are possible. No Yes Use compensation to change the count value to set Yes Yes ocks certain keys to prevent accidental operation. The key protection level, kp-1 to kp-4, determines which keys are locked when the key protection is ON. The locked keys are crossed out in the diagram on the right. Setting procedure Change the value of the digits with the corresponding keys, 1 to Change the value of the digits with the corresponding keys, 1 to 6. value.... Code Key to change the plus or minus sign of the set value. (+) (blank) (-) Sequence when changing the key protection level using the Increment Keys (1 to 6). <KP 1> <KP 3> <KP > <KP-4> Teaching Mode Prescale value (PS) Set value 1 (two-stage model only) (SET1) Set value (SET) No Yes --- By setting the conversion count value and pressing the TEAC Key, the prescale value is automatically calculated and set. No Yes --- By pressing the TEAC Key, the Present value is set as the set value. No Yes Note: 1. Settings changed in setting mode are not effective until run mode is entered.. Control output is prohibited in teaching mode. Output is OFF in coincidence-on operation and ON in coincidence-off operation. 3. The TEAC Key is disabled when the is turned OFF, when no teaching is possible. Other functions are enabled regardless of whether the is turned ON or OFF. 1

11 Examples Run Mode Changing the Set Value 1. DISPAY Key to change the displayed preset value 1 and during operation. Batch Set Value Change (Applicable to Standard Models Only) 1. Selecting Batch Count Display Switch the count display over to batch count display. BATC Key.. Change the set value from 5 to 1,5. Pressing keys 1 through 6 increments the corresponding column by1. Non-significant zeros are normally not shown on the set value display.. Batch Set Value Change Change the batch set value while the batch count is displayed. Pressing keys 1 through 6 increments the corresponding column by 1. Non-significant zeros are normally not shown on the set value display. In order to switch the batch count display over to the count display, press the DISPAY Key. Setting Mode Changing Settings in the Function Setting Mode 1. MODE Key to switch from run mode to setting mode. The Counter will continue operation if switched from run mode to function setting mode during operation. The MODE Key will be locked if the key protection function is enabled. Settings changed in the function setting mode are not effective until run mode is entered. As the operating conditions will change in this case, always reset operation with the RESET Key or a reset.. MODE Key to scroll successively through the items that can be set. Release the MODE Key to select the desired item. 11

12 3. Changing the selected item MODE Key until the desired item appears Change the item setting by pressing keys 1 through 6. (Press the DISPAY Key to switch back from function setting mode to run mode.) DISPAY Key to return to Run mode from Setting mode. Teaching Mode (± Range Models Only) Changing to Teaching Mode (Power Must be ON) Change from run mode to teaching mode. TEAC Key. If prescale teaching is not required, press the MODE Key and go to Set Value 1 Teaching. Prescale Teaching 1. Perform prescale teaching of the in teaching mode. The prescale display shows... Set 1 cm as a converted count value, for example. Pressing keys 1 through 6 increments the corresponding column by 1. By pressing one of keys 1 through 6, the counter PV (present value) display indicates. 1

13 3. Input a count signal corresponding to the conversion count value through the external sensor. The display on the right side indicates that an of 5 counts has been from the external sensor with the controlled object moved 1 cm. Set Value 1 Teaching 1. MODE Key to perform the teaching of set value 1, provided that the is a two-stage model.. Input an appropriate count signal from the external sensor. 3. Register the count value 5 as the set value, for example. TEAC Key. The teaching set value is displayed while the TEAC Key is pressed. 4. Perform prescale value teaching per count. TEAC Key. (Prescale value. = 1 cm/5) If the conversion count value at step 3 is a negative value, the prescale value will be calculated using the absolute value of the conversion count value. The fraction is rounded off to calculate the prescale value. While the TEAC Key is pressed, the teaching prescale value (i.e.,.) is displayed. Set Value Teaching (Two-stage Models Only) Perform the same procedure as Set Value 1 Teaching above. DISPAY Key to return to run mode from teaching mode. 13

14 Input Modes and Count Value Count CP1 Gate CP Count 1 Up (increment) mode A Inhibit 3 A 4 5 Count CP1 Gate CP Count n Down (decrement) mode A Inhibit n-1 n- n-3 A n-4 n-5 Gate CP1 Count CP Count 1 A Inhibit A Gate CP1 Count CP Count n n-1 A Inhibit n- A n-3 n-4 n-5 Up/Down A Command mode Up/Down B Individual mode CP1 CP A A CP1 CP Count Count Up/Down C Phase difference mode BB BB Note 1 Note Note 3 A: Minimum signal width; B: Must be at least 1/ of minimum signal width. Signals may not be counted if the minimums for A and B are not met. Set the same counting speed for CP1 and CP when in Up/Down C mode. and Count Signal No-voltage Voltage Short-circuit 4.5 to 3 VDC Open circuit to VDC 14

15 Input/Output Mode Setting -B operation applies for 1-stage models only. Output Input mode mode Up Down Up/Down A.B.C N 999,999 Preset Preset 1 F Outputs and present value display are maintained until reset. 999,999 Preset Preset 1 C Present value display runs continuously. Outputs are maintained until reset. 999,999 Preset Preset 1 R Present value is placed in reset start status as soon as count up is reached. The count up is not displayed. Outputs are 1-shot and operate repeatedly. is self-holding, and goes off after expiration of the 1-shot period for. One-shot time periods for and are independent. 999,999 Preset Preset 1 Present value is placed in reset start status as soon as count up is reached. Outputs are 1-shot and operate repeatedly. is self-holding, and goes off after expiration of the 1-shot period for. One-shot time periods for and are independent.

16 Output Input mode mode Up Down Up/Down A.B.C K 999,999 Preset Preset 1 P Present value runs continuously. is self-holding, and goes off after expiration of the 1-shot period for. One-shot time periods for and are independent. 999,999 Preset Preset 1 Q Present value display does not change during 1-shot time period, but reset start status is returned to as soon as count is reached. Outputs are 1-shot and operate repeatedly. is self-holding, and goes off after expiration of the 1-shot period for. One-shot time periods for and are independent. 999,999 Preset Preset 1 A Present value runs continuously through 1-shot time period and returns to reset start status immediately afterward. Outputs are 1-shot and operate repeatedly. is self-holding, and goes off after expiration of the 1-shot period for. One-shot time periods for and are independent. 999,999 Preset Preset 1 Present value and output 1 maintain status until reset. and operate independently.

17 One-shot output from Self-holding output One-shot output from Self-holding output One-shot outputs can be set to between 1 and 1, ms. Batch Counter Operation The batch counter counts the number of times set value is reached for 1-stage models, and the number of times set is reached for -stage models. Batch count reset Batch count set value The batch count output holds until reset by the batch count reset. The present value of the batch count advances continuously. Batch count present value Batch output 1. The batch count present value remains at while the batch count reset is ON.. When the batch count set value is, the batch count will proceed, but there will be no output. 3. When the batch count present value exceeds 9999, it returns to. 4. The batch count present value and output do not affect the RESET Key or reset. -C operation applies for 1-stage models only. 5. When power is interrupted and the batch count output is ON, the output will be ON when power returns. 6. When a batch count set value which is greater than the present value is changed to a set value which is less than the present value, the output will go ON. 7. If, after the output has gone ON, the set value is changed to a set value which is greater than the present value, the output will remain ON. Output mode K Comp. Input mode Up/Down A.B.C 999,999 Comp. Set Set 1-999,999 D Present value increments and decrements within displayable range. Outputs go ON for one-shot. Comp. 999,999 Comp. Set Set 1-999,999 Present value increments and decrements within displayable range. Outputs are ON during the count is equal.

18 Output mode Comp. Input mode Up/Down A.B.C 999,999 Comp. Set Set 1-999,999 Present value increments and decrements within displayable range. is ON whenever present value is less than or equal to Set 1; is ON whenever present value is greater than or equal to Set. Comp. 999,999 Comp. Set Set 1-999,999 Present value increments and decrements within displayable range. is ON whenever present value is greater than or equal to Set 1; is ON whenever present value is greater than or equal to Set. Edge evel One-shot output Instantaneous (equals) output Self-holding output/level One-shot outputs can be set to between 1 and 1, ms. Note: 1. Counting s are not applied while the reset is ON.. One-shot outputs, when ON, are turned OFF when the reset goes ON. 3. One-shot outputs, when ON, are left ON for the one-shot time period when the compensation goes ON 4. One-shot outputs, when ON, are reset and the one-shot output is restarted if a preset designating the output is reached. 5. The compensation is valid only when the present value is being incremented.

19 Dimensions Note: All units are in millimeters unless otherwise indicated. Flash Mounting 7 1 M3.5 terminal screw (effective length: 6 mm) Flash Mounting Adapter Panel panel thickness Panel Cutouts Panel cutouts are as shown at right. (according to DIN437) min. 8 min. 19

20 Installation Terminal Arrangement -B (standard type) 1 Stage, Contact and NPN Transistor Outputs -B -BV V CP CP1 Gate /4 VDC Output common -C (± range type) 1 Stage, Contact and NPN Transistor Outputs -C -CV CP CP1 Gate V 1/4 VDC Output common (-) (+) Batch count reset (-) power supply (+) OUT Unused Compensation (-) power supply (+) OUT Unused Key protection OUT Batch Key protection OUT ( ) (+) 1 to 4 VAC/4 VAC 1 to 4 VDC Unused ( ) (+) Unused 1 to 4 VAC/4 VAC 1 to 4 VDC 1 Stage, Contact and PNP Transistor Outputs -BP -BVP V CP CP1 Gate 1/4 VDC Output common 1 Stage, Contact and PNP Transistor Outputs -CP -CVP V CP CP1 Gate 1/4 VDC Output common Batch count reset (-) power supply (+) OUT Unused Compensation (-) power supply (+) OUT Unused Key protection OUT Batch Key protection OUT Unused 1 to 4 VAC/4 VAC ( ) (+) 1 to 4 VDC Unused 1 to 4 VAC/4 VAC ( ) (+) 1 to 4 VDC Stages, Contact and NPN Transistor Outputs -BW -BWV V CP CP1 Gate 1/4 VDC Output common Stages, Contact and NPN Transistor Outputs -CW -CWV V CP CP1 Gate 1/4 VDC Output common Batch counter reset (-) power supply (+) OUT 1 Compensation (-) power supply (+) OUT 1 OUT OUT Key protection OUT OUT 1 Batch Key protection OUT OUT Unused 1 to 4 VAC/4 VAC 1 to 4 VDC ( ) (+) 1 to 4 VAC/4 VAC 1 to 4 VDC ( ) (+)

21 -B (standard type) -C (± range type) Stages, Contact and PNP Transistor Outputs -BWP -BWVP V CP CP1 Gate 1/4 VDC Output common Stages, Contact and PNP Transistor Outputs -CWP -CWVP V CP CP1 Gate 1/4 VDC Output common Batch count reset (-) power supply (+) OUT 1 OUT Compensation (-) power supply (+) OUT 1 OUT Key protection OUT OUT Batch Key protection OUT OUT to 4 VAC/4 VAC 1 to 4 VDC ( ) (+) Unused 1 to 4 VAC/4 VAC ( ) (+) 1 to 4 VDC Note: Do not connect unused terminals. Connections The s of the are no-voltage (short-circuit or open) s and voltage s. (Key protection only for no-voltage s) No-voltage Inputs Open Collector Voltage Output Contact Input V for CP CP1 Gate 1/4-V output V for CP CP1 Gate 1/4-V output V for CP CP1 Gate 1/4-V output *: Transistor ON *: Relay ON *: Transistor ON No-voltage Input Signal evels No-contact Contact 1. igh level Transistor ON Residual voltage: V max. Impedance when ON: 1 kω max.. ow level Transistor OFF Impedance when OFF: 1 kω max. Use contacts which can adequately switch ma at 5 V 1

22 Voltage Inputs NPN Transistor PNP Transistor Contact Input V for CP CP1 Gate 1/4-V output V for CP CP1 Gate 1/4-V output V for CP CP1 Gate 1/4-V output *: Transistor OFF Voltage Input Signal evels 1. igh level 4.5 to 3 VDC. ow level to VDC *: Transistor ON *: Relay ON 3-wire DC type(npn) 3-wire DC type (PNP) Photoelectric sensor E3S-A/B Output (black) 1 to 4 V (brown) V (blue) Photoelectric sensor E3S-A/B Output (black) 1 to 4 V (brown) V (blue) (-) power supply (+) (-) power supply (+) -B, BV -BV *Models ending in -BV have reversed logic. Using the external power supply Photoelectric sensor E3S-A/B Output (black) 1 to 4 V (brown) Proximity sensor EE-X E Output (black) 1 to 4 V (brown) V (blue) V (blue) (-) power supply (+) (-) power supply (+) -BV -B, BV *Models ending in -BV have reversed logic.

23 Precautions Power Supply The capacity of the external power supply is ma at 1 VDC/8 ma at 4 VDC switchable. When using a 4 VAC/1 to 4 VDC power supply type, reduce the load with the power supply voltage, as shown in the following diagram (When supplying external power). oad current (ma) Supply voltage (VDC) 1 VDC 4 VDC Power Supplies When turning the power ON and OFF, signal reception is possible, unstable, or impossible as shown in the diagram below. The unstable period will vary with power supply voltage, and the load conditions on external power supplies. Power supply ON OFF to 5 ms 1 ms to 1. s Input impossible Possible impossible Unstable A switching regulator is used in the internal circuits of counters with 1-to-4-VAC or 1-to-4-VAC specifications, causing an inrush current (approx. 1.5 A) to flow when power is turned on. If the capacity of the power supply to the counter is insufficient, the counter may not start operation. Be sure to provide adequate capacity (recommended supply capacity; 5 W min.) Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately. DIP Switch Setting Changes Any changes in the DIP switch settings while power is being supplied is invalid. Restart the power supply. Self-diagnostic Function The following displays will appear if an error occurs. The present value and output enter the same status as after pressing the RESET Key. Display Error Output status * ** Present value below min. Present value above max. No change Correction Press RESET Key or reset Function setting No change CPU OFF Press RESET Key Memory Set at the factory *Displayed when the present value has fallen below the min. value in the -C (±range type). **Displayed when the present value has exceeded the max. value in the -C (±range type). Operating Environment When using the Counter in an area with much electronic noise, separate the Timer, wiring, and the equipment which generates the signals as far as possible from the noise sources. It is also recommended to shield the signal wiring to prevent electronic interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions might damage the outer casing of the Counter. Using the Prescale Function When setting the prescale value, be sure that the set value satisfies this equation: set value max. value - prescale value. (if the prescale value is 1,5, ,5 = max.) If a higher value is used, the output may be affected, so make sure that the output is produced before starting operation. Changing Set Values When changing the set value while the Counter is operating, the output will be produced if the set value ever equals the present value. To avoid triggering the output, begin by incrementing a higher digit to a large number. ting with a Set Value of When resetting is performed with the set value set to, no output will be given for the safety reasons once the reset is turned OFF (except for the -C). 3

24 Output Delay The following table shows the delay from when the present value passes the set value until the output is produced. (The delay is the result of output control time, signal transmission time, relay switching time, etc.) Actual measurements in N and K modes. Control output Max. counting speed Output delay* Contact output 1, 3 z {cps} to 4 ms 1 kz {cps} 4.7 to 5.8 ms 5 kz {cps} 4.4 to 5.4 ms 1 kz {cps} 4.3 to 5.3 ms Transistor output 1, 3 z {cps} 13.5 to ms 1 kz {cps}.59 to.81 ms 5 kz {cps}.9 to.44ms 1 kz {cps}.4 to.36ms Batch outputs 3 z {cps} 13.6 to. ms 1 kz {cps}.7 to.94 ms 5 kz {cps}.4 to.57ms 1 kz {cps}.37 to.49ms *The variation in delays is due to different modes and conditions. For systems where the delay is a problem, take actual measurements under operating conditions. Max. Count Speed of Batch Counter The maximum count speed of the batch counter is 1 kz (cps). The batch counter counts the number of count-up times at the last stage (i.e., the number of preset-value counts if the is a one-stage model and the number of SET preset-value counts if the is a two-stage model). An interval of 1 ms or more is required before the batch counter counts up again after it has counted up. Response Delay Time for ting (Transistor Output) Take the following output delays into consideration after the reset signal is turned ON and the output is turned OFF. Minimum reset signal width Output delay time 1 ms.8 to 1. ms ms to 5 ms Other When the Counter is installed in a control box and tests are conducted which may damage the Counter s internal circuitry (for example, a test measuring the maximum voltage difference between the control circuit and metal components), remove the Counter from the control box or short-circuit the terminals. A DIMENSIONS SOWN ARE IN MIIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by.357. Cat. No. M9-E1-1B OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Measuring and Supervisory Controls Division 8th Fl., Crystal Tower Bldg., 1--7, Shiromi, Chuo-ku, Osaka Japan Phone: (81) Fax: (81) Printed in Japan C (119) 4

Self-powered Counter

Self-powered Counter Self-powered Counter Subminiature Totalizing Counter Requires No External Power Supply DIN-sized 48 24 mm Wire-wrap terminal and screw terminal types available. AC/DC voltage, DC voltage, and No-voltage

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

Count/Time Totalizers

Count/Time Totalizers /Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_5_3 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC

More information

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately) Digital Panel Meter Subminiature Digital Panel Meter that Accepts DC Input Ultra-compact DIN-size (48 x 24 (W x H)) body. Mounting thickness of only 2 mm required. Highly visible display with 10.2-mm-high

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_

More information

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder Rotary Encoder New General-purpose Incremental Rotary Encoder A wide operating voltage range of 5 to 24 VDC (open collector model). Resolution of 2,000 pulses/revolution in 40-mm housing. can be adjusted

More information

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222 EECTRIC (with pre-scaling function) C-S Counters C-S -digit type -digit type pin type type U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD

More information

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS CSM_H3DS_DS_E_2_1 DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock.

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE CSM_H3DE_DS_E_3_2 DIN Track Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except

More information

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN

More information

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals MOS FET Relay GVM SSR for Switching Analog Signals, with an Insulation Value of. kvac between Input and Output Terminals Switching minute analog signals. Linear voltage and characteristics. Switching AC

More information

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures

More information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000 Incremental 60-mm-dia. Rotary Encoder E6F-C The Strongest Shaft for Tough Jobs The strongest shaft of any OMRON Incremental Encoder (120 N in the radial direction and 50 N in the thrust direction). Water-

More information

Bulletin 700-HX Multifunction Digital Timing Relay

Bulletin 700-HX Multifunction Digital Timing Relay Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

Multifunctional counter tico 772/773/774

Multifunctional counter tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48

More information

Process Meter. Applicable

Process Meter. Applicable 9 Process Meter Advanced Intelligent Signal Processor Accepts Voltage/Current Input 1 Programmable through the front panel or via RS-232C, RS-485, or RS-422 1 Programming with easy setup and calibration

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A PCB Relay Low-profile power relay with maximum switching of 8 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm. RoHS

More information

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance Built-in Amplifier Photoelectric Sensor Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance Satisfies the requirements of IP67, NEMA 6P, and IP67G (oil-tight).

More information

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately) Distance-settable Photoelectric Sensor Switching between background and foreground suppression (BGS/FGS) enables detecting a variety of objects under various background/foreground conditions. Influence

More information

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Ordering Information. Stepping Relay Unit G9B. Model Number Legend Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset

More information

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm. Distance-settable Photoelectric Sensor FC-AL Distance-settable Photoelectric Sensor with Background Suppression and Visible Laser Beam Reliable background suppression detection, even of shiny objects Detection

More information

Self-powered Tachometer

Self-powered Tachometer Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution

More information

High-precision Optical Switch

High-precision Optical Switch High-precision Optical Switch Optical System Achieves 1-mm Operating Position Repeatability in this 4-way Switch A knife-edge mechanism in the optical system provides greater precision for a more stable

More information

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2 Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending

More information

Model Number Structure

Model Number Structure Digital Controller CSM DS_E_3_1 Advanced Digital Controllers Ideal for Worldwide Use Modular structure High-accuracy: 100 ms sampling (for analog input) Auto-tuning and fuzzy self-tuning Conforms to international

More information

Model Number Structure

Model Number Structure Digital Controller CSM DS_E_3_1 Advanced, Compact Digital Controllers IP66/NEMA4 (indoor use) front face. Modular structure, one-stock type. Heating/cooling control. Serial communications (RS-232C and

More information

Incremental Rotary Encoder

Incremental Rotary Encoder Incremental Rotary Encoder IP64 Drip-proof Construction (IP65f for ) The incorporates a rubber-seal bearing cover of IP64 dripproof construction thus ensuring ease of use in places with water dripping

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min Weekly Time Switch H5S Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1

More information

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

Absolute Rotary Encoder

Absolute Rotary Encoder Absolute Rotary Encoder Use the Tough (Rated IP64 for Degree of Protection) Combined with a PLC or Cam Positioner for Optimum Control and Ease-of-Use Incorporates a sealed bearing, meeting IP64 for durability

More information

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that

More information

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max. 96 PHOTO PHOTO ON/OFF Input SERI Related Information General terms and conditions... F-3 General precautions... P.9 MEASURE panasonic.net/id/pidsx/global Multi-functional D rail mounting slim sensor controller

More information

Single-phase Voltage Relay

Single-phase Voltage Relay New Product Single-phase Voltage Relay K8AB-VS Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Long-distance detection of up to 6,000 mm supports a wide variety of applications. The Sensor is not

More information

Indicator (4digit) (5digit) 8-pin plug counter

Indicator (4digit) (5digit) 8-pin plug counter 8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC

More information

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION

More information

Safety Relay Unit. OFF-delay time

Safety Relay Unit. OFF-delay time Safety Relay Unit The Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay poles, as well as

More information

Model Number Structure

Model Number Structure Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported

More information

PLC-K506 Series FEATURES DESCRIPTION FEATURES

PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION

More information

DIN 48 SIZE LCD ELECTRONIC COUNTER. FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1

DIN 48 SIZE LCD ELECTRONIC COUNTER. FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1 C4-W DIN SIZE CD EECTRIC COUNTER C4-W U File No.: E CS File No.: R99.89 -pin type.89 64.5.59 mm inch type FETURES. Two-stage presetting (upper and lower limits) Count Output Output SET SET. Bright and

More information

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10

More information

Single-phase Current Relay

Single-phase Current Relay New Product Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. Monitor for overcurrents or undercurrents. Manual resetting and automatically resetting

More information

Capacitive Proximity Sensor

Capacitive Proximity Sensor Capacitive Proximity Sensor Compact and Ideal for Robot Hands and Various Built-in Applications for LCD, Wafer, and PDP (Plasma Display Panel) Detection Flat head is only 5.5-mm thick. Robot Cable ensures

More information

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model 60-mm-dia. Encoder Rugged Encoder for High-precision Detection of Automatic Machine Timing Rugged construction with the highest shaft loading. Radial: 120 N, Thrust: 50 N IP65f water- and oil-proof construction.

More information

Rectangular Proximity Sensor

Rectangular Proximity Sensor Rectangular Proximity Sensor A Variety of Models Available for a Wide Range of Applications ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575

More information

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches Weekly Timer Timer Provides Prompted Programming, Flexibility in Programs Within the Week AM/PM display 24 program steps A different program possible each day Over midnight settings possible Two independent

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

Incremental Rotary Encoder E6B2

Incremental Rotary Encoder E6B2 Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

Incremental Rotary Encoder

Incremental Rotary Encoder Incremental Rotary Encoder Industrial Strength Encoder Meets World-Class Standards Drip-proof construction Shaft withstands heavy loads, 5 kgf radially, 3 kgf thrust (axially) Short circuit protection

More information

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage ow-profile Relay with Various Models ow profile:.7 mm in height. Creepage distance 8mm between coil and contacts 0 kv Impulse withstand voltage Models with AC coil available. High-Inrush model available

More information

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.

More information

4 channels High Speed Counter Unit

4 channels High Speed Counter Unit 2/4 channels High Speed Counter Units 2 or 4 Channels High Speed Counter Units for CS PLC. Frequency up to 500 khz, closed loop response time as low as 0. ms. 4 Digital In, 4 Digital Out and 28 soft outputs

More information

Details on the New G2RS

Details on the New G2RS New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98-mW pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Fully sealed construction. Unique moving

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Revolutionary High-performance High-quality Sensor with Built-in Amp can be adjusted in seconds because the optical axis coincides with the mounting axis. Highly visible spot on white

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

FA Wireless SS Terminals

FA Wireless SS Terminals FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and

More information

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor Authorised Distributors:- AS & AAIN INDIA PVT TD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) Tel : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Fiber Glossy Object

More information

Position Indicator with/without Limit Values

Position Indicator with/without Limit Values .1 Position Indicator with/without Limit Values Large, 6-digit, 14 mm high LED display Prescaler 2 variable limit values Eeasy direct selection by 2 function keys Rrelay output with two change-over contacts

More information

Correction Reissue. Product Discontinuation Notices

Correction Reissue. Product Discontinuation Notices PRODUCT NEWS Correction Reissue Product Discontinuation Notices January 6, 2014 Pressure Sensors No. 2011265E(2) Discontinuation Notice of Pressure Sensor (Stainless diaphragm) E8AA series (Special product),

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

EE-SX770/771/772/870/871/872(A/P/R)

EE-SX770/771/772/870/871/872(A/P/R) EE-SX770/771/772/870/871/872(A/P/R) Thin, Compact Photomicrosensor with Attached Cable H Next generation design available with NPN or output H Allows standard M3-screw mounting H Twenty-four models available

More information

Model Number Structure

Model Number Structure Up/Down Counting Meter K3NC An Ideal Interface for High-speed Up/Down Counting and Serial Communications 50-kHz input range for high-speed signal processing. A wide selection of outputs: relay, transistor,

More information

Digital Amplifier Ultrasonic Sensor E4C-UDA Series

Digital Amplifier Ultrasonic Sensor E4C-UDA Series Digital Amplifier Ultrasonic Sensor E4C-UDA Series A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Sensor Heads Head Variations 300-mm Model E4C-DS30 Sensing Distance:

More information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22. Measuring and Monitoring Relays K8AB Series Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions. Single-phase

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model Solid-state Timer PCB-mounting Time Unit for High-frequency Applications Ideal for high-frequency applications with 1-ms reset time (including during operation) either for power resets or external resets.

More information

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately) Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle

More information

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1 Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.

More information

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges NO: RL-159 PRODUCT: G3PA SSRs, G32A Cartridges DATE: January 2017 TYPE: Partial Discontinuation Notice Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X

More information