POWER FACTOR CORRECTION OF MACHINE LABORATORY AND CNC MACHINE BY USING IPFC CONTROLLER

Size: px
Start display at page:

Download "POWER FACTOR CORRECTION OF MACHINE LABORATORY AND CNC MACHINE BY USING IPFC CONTROLLER"

Transcription

1 POWER FACTOR CORRECTION OF MACHINE LABORATORY AND CNC MACHINE BY USING IPFC CONTROLLER Submitted by:- DEEPAK KUMAR BAGHAR PRAVAT KUMAR PATRA DEVIPRASAD SINGHDEO SARTHAK PATI ASHIS PANDA ANUP MANGARAJ EER EER EER EER EER EER109 GUIDED BY Shri Surya Narayan Sahu

2 INTRODUCTION Power factor is the ratio of true power or watts to apparent power or volt amps. They are identical only when current and voltage are in phase then the power factor is1.0. The cosine of angle between voltage and current in ac circuit is known as power factor. In ac circuit there is generally a phase difference φ between voltage and current. The term cosφ is called the power factor of circuit VI cosφ represent the active power in Watt or KW VIsin φ represent the reactive power in VAR or KVAR VI represents apparent power in VA or KVA Power factor cosφ= (active power / apparent power)=(kw/kva)

3

4 The lagging reactive power is responsible for the low power factor. It is clear from the power triangle that smaller the reactive power component higher is the power factor of the circuit. KVAR=KVA sniφ=(kw/ cosφ)* sinφ KVAR=KW tanφ

5 INSTANTANEOUS POWER As in DC circuits, the instantaneous electric power in an AC circuit is given byp=vi where V and I are the instantaneous voltage and current. Instantaneous voltageand current. Since V = Vm sinωt & I = Im sin (ωt - φ)

6 Then the instantaneous power at any time t can be expressed as Pinstanteneous = Vm Im sinωt sin (ωt-φ) After using trigonometric identity:sin (t-φ) = sinωt cosφ- cosωt sinφ The power becomes: instantaneous = Vm Im sin 2ωt cosφ - Vm Im sinωt sinφ cos ωt

7 NEEDS OF POWER FACTOR CONTROLLER Power factor correction (PFC) is a technique of counteracting the undesirable effects of electric loads that create a power factor that is less than one. Power factor correction may be applied either by an electrical power transmission utility to improve the stability and efficiency of the transmission network or correction may be installed by individual electrical customers to reduce the costs charged to them by their electricity supplier.

8 TYPES OF POWER FACTOR CONTROLLER Passive PFC This is a simple way of correcting the nonlinearity of a load by using capacitor banks. Active PFC An active power factor corrector (active PFC) is a power electronic system that controls the amount of power drawn by a load in order to obtain a Power factor as close as possible to unity.

9 CAPACITIVE POWER FACTOR CORRECTION (CPFC) Capacitive Power Factor correction is applied to circuits, which include induction motors as a means of reducing the inductive component of the current and thereby reduce the losses in the supply. There should be no effect on the operation of the motor itself. An induction motor draws current from the supply, which is made up of resistive components and inductive components.

10 DIFFERENT TYPES OF CAPACITIVE POWER FACTOR CORRECTION Bulk correction Static correction Inverter Solid-state soft starter Bulk correction

11 Static correction Inverter Static Power factor correction must not be used when a variable speed drive or inverter controls the motor. The connection of capacitors to the output of an inverter can cause serious damage to the inverter and the capacitors due to the high frequency switched voltage on the output of the inverters.

12 Solid state soft starter.

13 HARDWARE AND ITS CONFIGURATION The design aims to monitor phase angle continuously and in the event of phase angle deviation, a correction action is initialized to compensate for this difference by continuous changing variable capacitors value via switching process. IPFC(Intellegent Power Factor Controller)

14 BENEFITS Three Phase Sensing - Accurate measurement of PF Fault Detection (Over Compensation, Under Compensation, Over Voltage, Over Current, Under Voltage, over harmonics voltage and current) Automatic or Manual Control (manual control with power backup option) Intelligent operation

15 CAPACITOR BANK A capacitor (originally known as a condenser) is a passive two-terminal electrical component used to store energy electro statically in an electric field.

16 CONTROLE SCHEME Circuit Diagram

17 Over voltage For all these above there is a threshold set through RS-232communication.When ever it crosses above that threshold particular alarm status will display on LCD. Under voltage For all these above there is a threshold set through RS-232communication.When ever it crosses above that threshold particular alarm status will display on LCD.

18 Over Compensation When all capacitor bank steps (max) gets OFF and IPFC still don t achieve required Target PF this alarm will display. Under Compensation When all capacitor bank steps(max) gets ON and IPFC still don t achieve required Target Power factor this alarm will display. Under Current Condition until current is restored above 50mA and all capacitor steps get disconnected.

19 PRACTICAL ANALYSIS

20 After Correction Of Machine Laboratory

21 PRACTICAL CORRECTION OF POWER FACTOR FOR CNC LABORATORY Before Correction

22 After Correction of CNC laboratory

23

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY:

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY: ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY: Faizhussain Arsiwala POWER FACTOR: The cosine of angle between voltage and current in an a.c. circuit is known as power factor.

More information

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS 40 CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS 3.1 INTRODUCTION The low power factor effects on transmission line, switchgear, transformers etc. It is observed that if the power

More information

ARDUINO BASED POWER FACTOR CORRECTION

ARDUINO BASED POWER FACTOR CORRECTION ARDUINO BASED POWER FACTOR CORRECTION 1 SHOBHA R.MANE, 2 ASHWINI A.KOLEKAR, 3 MAITHILI M. MOLAJ, 4 SADHANA V.PATIL, 5 MAZHARHUSSAIN N. MESTRI 1,2,3,4,5 Electrical Department, Shivaji University, Kolhapur,

More information

Power Factor. Power Factor Correction.

Power Factor. Power Factor Correction. Power Factor. Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively

More information

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry. Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry. Bhargav Jayswal 1, Vivek Khushwaha 2, Prof. Pushpa Bhatiya 3 1.2 B. E Electrical Engineering, Vadodara

More information

POWER FACTOR CORRECTION USING BOOST CONVERTER

POWER FACTOR CORRECTION USING BOOST CONVERTER POWER FACTOR CORRECTION USING BOOST CONVERTER Hiten Pahilwani Accenture Services, Mumbai 400708 ABSTRACT In an electrical Power systems, a load with a low power factor draws more current than a load with

More information

Influence of Switching Elements on Harmonics and Power Factor Improvement

Influence of Switching Elements on Harmonics and Power Factor Improvement International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 7, Issue 12 (July 2013), PP. 18-24 Influence of Switching Elements on Harmonics

More information

Monitoring And Control Over Power Factor By Using Pic Micro-Controller

Monitoring And Control Over Power Factor By Using Pic Micro-Controller International Journal Of Scientific Research And Education Volume 2 Issue 7 Pages 1351-1363 July-2014 ISSN (e): 2321-7545 Website: http://ijsae.in Monitoring And Control Over Power Factor By Using Pic

More information

UPQC (Unified Power Quality Conditioner)

UPQC (Unified Power Quality Conditioner) A Unified Power Quality Conditioner (UPQC) is a device that is similar in construction to a Unified Power Flow Conditioner (UPFC). The UPQC, just as in a UPFC, employs two voltage source inverters (VSIs)

More information

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS 86 CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS 5.1 POWER QUALITY IMPROVEMENT This chapter deals with the harmonic elimination in Power System by adopting various methods. Due to the

More information

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER P.R.Hujband 1, Dr. B.E.Kushare 2 1 Department of Electrical Engineering, K.K.W.I.E.E.R,

More information

Power Quality Monitoring and Power Metering Tutorial

Power Quality Monitoring and Power Metering Tutorial Power Quality Monitoring and Power Metering Tutorial Power generation and transmission today are accomplished using three phase alternatingcurrent. To understand electrical power quality monitoring and

More information

PFC Lite. How it works OMNIVERTER. OMNIVERTER November 14, 2015 Slide 1

PFC Lite. How it works OMNIVERTER. OMNIVERTER November 14, 2015 Slide 1 How it works OMNVERTER November 14, 2015 Slide 1 OMNVERTER How it works PFC Utility Displacement Power Factor correction -By injecting reactive current at the fundamental frequency either leading or lagging

More information

Chapter 2 Shunt Active Power Filter

Chapter 2 Shunt Active Power Filter Chapter 2 Shunt Active Power Filter In the recent years of development the requirement of harmonic and reactive power has developed, causing power quality problems. Many power electronic converters are

More information

LV PFC Basics. Power Factor Correction - Basics FK PC PM PFC Januar 07 Page: 1

LV PFC Basics. Power Factor Correction - Basics FK PC PM PFC Januar 07 Page: 1 LV PFC Basics Power Factor Correction - Basics FK PC PM PFC Januar 07 Page: 1 What are the different types of loads? Ohmic loads Lighting bulbs Iron Resistive heating Capacative loads Capacitors Underground

More information

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs Mr. P. Biswas, ABB ABSTRACT The Indian Railways employ single phase 25 kv Traction sub-station (TSS) for supplying power

More information

INTRODUCTION PROPOSED SOLUTION STEPS TAKEN. MATLAB Simulation

INTRODUCTION PROPOSED SOLUTION STEPS TAKEN. MATLAB Simulation INTRODUCTION In a circuit with reactive (inductive or capacitive) loads, the voltage and current are about 90 degrees out of phase. Inductive loads are mainly found in industries that use heavy equipment

More information

Dynamic Harmonic Mitigation and Power Factor Correction

Dynamic Harmonic Mitigation and Power Factor Correction Dynamic Harmonic itigation and Power Factor Correction Cesar Chavez, Eng Engineering Dept., Arteche. Naucalpan, Edo. de éxico, éxico John A. Houdek, ember, IEEE President, Allied Industrial arketing ilwaukee,

More information

Thyristorised Automatic Power Factor

Thyristorised Automatic Power Factor Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor

More information

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display. Chapter 7 Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display. Learning Objectives 1. Understand the meaning of instantaneous and average power, master AC power notation,

More information

ISSN Vol.03,Issue.42 November-2014, Pages:

ISSN Vol.03,Issue.42 November-2014, Pages: ISSN 2319-8885 Vol.03,Issue.42 November-2014, Pages:8462-8466 www.ijsetr.com Design and Simulation of Boost Converter for Power Factor Correction and THD Reduction P. SURESH KUMAR 1, S. SRIDHAR 2, T. RAVI

More information

Power Factor and Power Factor Correction

Power Factor and Power Factor Correction Power Factor and Power Factor Correction Long gone are the days when only engineers that worked with large electric motors and high power electric loads need worry about power factor. The introduction

More information

AC Fundamental. Simple Loop Generator: Whenever a conductor moves in a magnetic field, an emf is induced in it.

AC Fundamental. Simple Loop Generator: Whenever a conductor moves in a magnetic field, an emf is induced in it. AC Fundamental Simple Loop Generator: Whenever a conductor moves in a magnetic field, an emf is induced in it. Fig.: Simple Loop Generator The amount of EMF induced into a coil cutting the magnetic lines

More information

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online): 2321-0613 Reactive Power Compensation by using FACTS Devices under Non- Sinusoidal Condition by

More information

A Single Phase Power Factor Correction Using Programmable Interface Circuit

A Single Phase Power Factor Correction Using Programmable Interface Circuit A Single Phase Power Factor Correction Using Programmable Interface Circuit Mrs.Shamal R.Padmawar ME student, Department of Electronics DPCOE, wagholi Pune, India shamalrpadmawar@gmail.com Abstract-Power

More information

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder 16.4. Power phasors in sinusoidal systems Apparent power is the product of the rms voltage and

More information

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE 98 CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE 6.1 INTRODUCTION Process industries use wide range of variable speed motor drives, air conditioning plants, uninterrupted power supply systems

More information

How Harmonics have led to 6 Power Factor Misconceptions

How Harmonics have led to 6 Power Factor Misconceptions Harmonic and Energy Saving Solutions How Harmonics have led to 6 Power Factor Misconceptions Tony Hoevenaars, P.Eng. Power Factor Misconceptions 1. Low power factor is normally caused by electric motors

More information

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: 2014-15) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (NEE-101) Roll No. Academic/26

More information

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS. 1 PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS. DEFINATIONS Working /Active Power: Normally measured in kilowatts (kw). It does the "work" for the system--providing the motion, torque,

More information

Lab 4 Power Factor Correction

Lab 4 Power Factor Correction Lab 4 Power Factor Correction Last Name: First Name: Student Number: Lab Section: Monday Tuesday Wednesday Thursday Friday TA Signature: Lab objectives o Introduction to Power Factor o Introduction to

More information

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives For your business and technology editors Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives The use of AC induction motors is essential for industry and utilities. AC induction

More information

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM Abstract Efficient operation of the electrical system of any facility is essential to controlling operational costs while maximizing

More information

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE 2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS 2.1.1 OBJECTIVE To study sinusoidal voltages and currents in order to understand frequency, period, effective value, instantaneous power and average

More information

DATA SHEET POWER CAPACITOR

DATA SHEET POWER CAPACITOR Issued August 2009 10470 DATA SHEET POWER CAPACITOR General Data * POWER FACTOR CORRECTION The power factor of a load is defined as the ratio of active power to apparent power, i.e. kw : kva and is referred

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

Operating Guide October 2006

Operating Guide October 2006 Operating Guide October 2006 Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which

More information

Sizing Generators for Leading Power Factor

Sizing Generators for Leading Power Factor Sizing Generators for Leading Power Factor Allen Windhorn Kato Engineering 24 February, 2014 Generator Operation with a Leading Power Factor Generators operating with a leading power factor may experience

More information

AC Power Instructor Notes

AC Power Instructor Notes Chapter 7: AC Power Instructor Notes Chapter 7 surveys important aspects of electric power. Coverage of Chapter 7 can take place immediately following Chapter 4, or as part of a later course on energy

More information

Modeling and Simulation of STATCOM

Modeling and Simulation of STATCOM Modeling and Simulation of STATCOM Parimal Borse, India Dr. A. G. Thosar Associate Professor, India Samruddhi Shaha, India Abstract:- This paper attempts to model and simulate Flexible Alternating Current

More information

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg. Aligarh College of Engineering & Technology (College Code: 19) Electrical Engg. (EE-11/21) Unit-I DC Network Theory 1. Distinguish the following terms: (a) Active and passive elements (b) Linearity and

More information

Power Factor Correction of Inductive Loads using PLC

Power Factor Correction of Inductive Loads using PLC Power Factor Correction of Inductive Loads using PLC Sayed Abdullah Sadat Member of Regime, National Load Control Center (NLCC) Afghanistan's National Power Utility (DABS) Sayed_abdullah@ieee.org E. Sreesobha

More information

Model φ/1φ Power Clamp-on Meter

Model φ/1φ Power Clamp-on Meter User's Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 382075 Product Page Model 382075 3φ/1φ Power Clamp-on

More information

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions Issue #65 - December 2012 Technical News Industrial Electrical and Automation Products, Systems and Solutions Part 2: Harmonics The link between harmonics and power factor Written by Justin Charlot Product

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA SETTING UP REACTIVE POWER COMPENSATION DEVICES SELECTING A REACTIVE POWER COMPENSATION DEVICE To effectively compensate the

More information

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018 Electrical Theory Power Principles and Phase Angle PJM State & Member Training Dept. PJM 2018 Objectives At the end of this presentation the learner will be able to: Identify the characteristics of Sine

More information

McGill Power Sales & Engineering, INC.

McGill Power Sales & Engineering, INC. 1 McGill Power Sales & Engineering, INC. Power Factor Correction Terry McGill President McGill Power Sales & Engineering Inc. 2007 Eaton Corporation. All rights reserved. Agenda What is power factor? What

More information

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER,

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER, 16th NATONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER, 2010 289 Single phase Active harmonic filters for Harmonic elimination and Power Factor correction for Distributed loads Vinod Gupta, Kamlesh

More information

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits 1. Objective AC Circuits In this lab, the student will study sinusoidal voltages and currents in order to understand frequency, period, effective value, instantaneous power and average power. Also, the

More information

Technical Application Papers No.8 Power factor correction and harmonic filtering in electrical plants

Technical Application Papers No.8 Power factor correction and harmonic filtering in electrical plants Technical Application Papers No.8 Power factor correction and harmonic filtering in electrical plants Index Technical Application Papers Power factor correction and harmonic filtering in electrical plants

More information

not to be republished NCERT ALTERNATING CURRENT Chapter Seven MCQ 1

not to be republished NCERT ALTERNATING CURRENT Chapter Seven MCQ 1 hapter Seven ALTERNATING URRENT MQ 1 7.1 If the rms current in a 50 Hz ac circuit is 5 A, the value of the current 1/300 seconds after its value becomes zero is (a) 5 2 A (b) 5 3/2 A (c) 5/6 A (d) 5/ 2

More information

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number:  Address: NORTH CAROLINA INTERCONNECTION REQUEST Utility: Designated Contact Person: Address: Telephone Number: Fax: E-Mail Address: An is considered complete when it provides all applicable and correct information

More information

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Application Guidance Notes: Technical Information from Cummins Generator Technologies Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 087 Power Factor DEFINITIONS What is Power Factor? Power factor is a way of identifying the electrical relationship

More information

Thyristorised Real Time Power Factor Correction (TRTPFC)

Thyristorised Real Time Power Factor Correction (TRTPFC) Thyristorised Real Time Power Factor Correction (TRTPFC) Sanjay N. Patel, 2 Mulav P. Rathod, 3 Keyur C. Patel, 4 Parth H. Panchal, 5 Jaimin N. Prajapati, 2 Asst.Prof, Electrical dept., SVIT Vasad, 3, 4,

More information

Question Paper Profile

Question Paper Profile I Scheme Question Paper Profile Program Name : Electrical Engineering Program Group Program Code : EE/EP/EU Semester : Third Course Title : Electrical Circuits Max. Marks : 70 Time: 3 Hrs. Instructions:

More information

SRI VIDYA COLLEGE OF ENGG AND TECH

SRI VIDYA COLLEGE OF ENGG AND TECH EEE6603 PSOC Page 1 UNIT-III REACTIVE POWER VOLTAGE CONTROL 1. List the various components of AVR loop? The components of automatic voltage regulator loop are exciter, comparator, amplifier, rectifier

More information

TRANSFORMER OPERATION

TRANSFORMER OPERATION Chapter 3 TRANSFORMER OPERATION 1 A transformer is a static device (no moving parts) used to transfer energy from one AC circuit to another. This transfer of energy may involve an increase or decrease

More information

Fundamentals of AC Power Measurements

Fundamentals of AC Power Measurements Fundamentals of AC Power Measurements Application Note Power analysis involves some measurements, terms and calculations that may be new and possibly confusing to engineers and technicians who are new

More information

THREE PHASE RECTIFIER TOPOLOGY WITH PRACTICALLY SINUSOIDAL INPUT CURRENTS

THREE PHASE RECTIFIER TOPOLOGY WITH PRACTICALLY SINUSOIDAL INPUT CURRENTS THREE PHASE RECTIFIER TOPOLOGY WITH PRACTICALLY SINUSOIDAL INPUT CURRENTS By D.Alexa, I.V.Pletea, N.Lucanu, E.Coca, L.Ţigaeru Technical University of Iasi, Faculty of Electronics and Telecommunications

More information

Study of Power Factor Correction in Single Phase AC-DC Converter

Study of Power Factor Correction in Single Phase AC-DC Converter Avneet Kaur, Prof. S.K Tripathi, Prof. P. Tiwari 89 Study of Power Factor Correction in Single Phase AC-DC Converter Avneet Kaur, Prof. S.K Tripathi, Prof. P. Tiwari Abstract: This paper is regarding power

More information

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line To Study The MATLAB Simulation Of A Single Phase And Transmission Line Mr. Nileshkumar J. Kumbhar Abstract-As an important member of FACTS family, (Static Synchronous Compensator) has got more and more

More information

POWER FACTOR CORRECTION AND ITS PITFALLS

POWER FACTOR CORRECTION AND ITS PITFALLS Technical Note No. May 1999 POWER FACTOR CORRECTION AND ITS PITFALLS This Technical Note considers power factor correction as applied by large customers and the possible consequences when power factor

More information

Interline Power Flow Controller: Review Paper

Interline Power Flow Controller: Review Paper Vol. (0) No. 3, pp. 550-554 ISSN 078-365 Interline Power Flow Controller: Review Paper Akhilesh A. Nimje, Chinmoy Kumar Panigrahi, Ajaya Kumar Mohanty Abstract The Interline Power Flow Controller (IPFC)

More information

Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems

Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems Brian Kingham, Utility Market Manager, Schneider Electric, PMC Division Abstract: Historical power quality measurement

More information

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring. Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring. Rosni Sayed Rajshahi University of Engineering & Technology Rajshahi-6204 Bangladesh A.H.M Iftekharul Ferdous

More information

VARIABLE FREQUENCY DRIVE

VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE Yatindra Lohomi 1, Nishank Nama 2, Umesh Kumar 3, Nosheen aara 4, Uday Raj 5 (Assistant Professor in Department of Electrical Engineering GIET Kota2) (Department of Electrical

More information

Performance of DVR & Distribution STATCOM in Power Systems

Performance of DVR & Distribution STATCOM in Power Systems International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 83 89 Performance of DVR & Distribution STATCOM in Power Systems Akil Ahemad Electrical

More information

Power Factor Improvement Using Static VAR Compensator

Power Factor Improvement Using Static VAR Compensator Power Factor Improvement Using Static VAR Compensator Akshata V Sawant 1 and Rashmi S Halalee 2 Department of Electrical and Electronics, B. V. Bhoomaraddi College of Engineering and Technology, Hubballi,

More information

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY LIST OF TOPICS 1 Electric Circuit Principles 2 Electronic Circuit Principles 3 Generation 4 Distribution 5 Utilisation The expected learning outcome is

More information

Alternating voltages and currents

Alternating voltages and currents Alternating voltages and currents Introduction - Electricity is produced by generators at power stations and then distributed by a vast network of transmission lines (called the National Grid system) to

More information

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION Important Instructions to examiners: 1. The answers should be examined by key words and not as word-to-word as given in the model answer scheme. 2. The model answer and the answer written by candidate

More information

Code No: R Set No. 1

Code No: R Set No. 1 Code No: R05310204 Set No. 1 III B.Tech I Semester Regular Examinations, November 2007 ELECTRICAL MACHINES-III (Electrical & Electronic Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions

More information

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar.

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar. Technical Report on Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by Dr. V. R. Kanetkar (February 2015) Shreem Electric Limited (Plot No. 43-46, L. K. Akiwate

More information

TOPOLOGICAL ISSUES IN SINGLE PHASE POWER FACTOR CORRECTION

TOPOLOGICAL ISSUES IN SINGLE PHASE POWER FACTOR CORRECTION TOPOLOGICAL ISSUES IN SINGLE PHASE POWER FACTOR CORRECTION A THESIS SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF TECHNOLOGY IN POWER CONTROL AND DRIVES By Ms. KURMA

More information

AC System Monitoring Device

AC System Monitoring Device AC System Monitoring Device Andrew Jarrett Project Adviser: Professor Steven D.Gutschlag Department of Electrical and Computer Engineering May 11, 2016 ABSTRACT This document covers the design of a device

More information

Power Factor Correction

Power Factor Correction EPCOS Product Profile (India) 2013 Power Factor Correction Power Quality Solutions www.epcos.com Preview U I I U Linear loads: voltage was followed by current. Non linear load produce non sinusoidal currents

More information

Power Factor Improvement in Switched Reluctance Motor Drive

Power Factor Improvement in Switched Reluctance Motor Drive Indian Journal of Scientific & Industrial Research Vol. 76, January 2017, pp. 63-67 Power Factor Improvement in Switched Reluctance Motor Drive M R Joshi 1 * and R Dhanasekaran 2 *1 Department of EEE,

More information

PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners

PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners International Journal of Computer and Electrical Engineering, Vol.3, No., February, PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners Karuppanan P and Kamala Kanta Mahapatra

More information

Chapter 31 Alternating Current

Chapter 31 Alternating Current Chapter 31 Alternating Current In this chapter we will learn how resistors, inductors, and capacitors behave in circuits with sinusoidally vary voltages and currents. We will define the relationship between

More information

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme Akanksha Mishra, Anamika Upadhyay Akanksha Mishra is a lecturer ABIT, Cuttack, India (Email: misakanksha@gmail.com) Anamika Upadhyay

More information

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS 84 CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS 4.1 INTRODUCTION Now a days, the growth of digital economy implies a widespread use of electronic equipment not only in the industrial

More information

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt 3 phase Power All we need electricity for is as a source of transport for energy. We can connect to a battery, which is a source of stored energy. Or we can plug into and electric socket at home or in

More information

Improve Power Factor and Reduce the Harmonics Distortion of the System

Improve Power Factor and Reduce the Harmonics Distortion of the System Research Journal of Engineering Sciences ISSN 2278 9472 Improve Power Factor and Reduce the Harmonics Distortion of the System Abstract Jain Sandesh, Thakur Shivendra Singh and Phulambrikar S.P. Electrical

More information

User's Manual. Model f/1f Power Clamp-on Meter

User's Manual. Model f/1f Power Clamp-on Meter User's Manual Model 382075 3f/1f Power Clamp-on Meter Introduction Congratulations on your purchase of the Extech Model 382075 Auto Range Power Clamp-On Meter. Careful use of this device, will provide

More information

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control Spring 2014 Instructor: Kai Sun 1 References Saadat s Chapters 12.6 ~12.7 Kundur s Sections

More information

The period is the time required for one complete oscillation of the function.

The period is the time required for one complete oscillation of the function. Trigonometric Curves with Sines & Cosines + Envelopes Terminology: AMPLITUDE the maximum height of the curve For any periodic function, the amplitude is defined as M m /2 where M is the maximum value and

More information

Power factor correction and harmonic filtering. Automatic power factor regulators R.1

Power factor correction and harmonic filtering. Automatic power factor regulators R.1 Power factor correction and harmonic filtering Automatic power factor regulators R.1 R.1 Automatic power factor regulators R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent

More information

LRC Circuit PHYS 296 Your name Lab section

LRC Circuit PHYS 296 Your name Lab section LRC Circuit PHYS 296 Your name Lab section PRE-LAB QUIZZES 1. What will we investigate in this lab? 2. Figure 1 on the following page shows an LRC circuit with the resistor of 1 Ω, the capacitor of 33

More information

Phase and Waveform Comparative Analysis for Electric Heater, Induction Motor and Static Capacitor

Phase and Waveform Comparative Analysis for Electric Heater, Induction Motor and Static Capacitor International Journal of Innovative Research in Education, Technology & Social Strategies IJIRETSS ISSN Print: 2465-7298 ISSN Online: 2467-8163 Volume 5, Number 1, March 218 Phase and Waveform Comparative

More information

Power Quality Compensation by using UPFC

Power Quality Compensation by using UPFC ISSN: 2454-132X Impact factor: 4.295 (Volume 4, Issue 2) Available online at: www.ijariit.com Power Quality Compensation by using UPFC P. Madhumathi madhumathi9196@gmail.com Vivekanada College of Engineering

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

SERIES A.C. CIRCUITS. Learning Objectives. This chapter discusses series AC circuits, and how they function

SERIES A.C. CIRCUITS. Learning Objectives. This chapter discusses series AC circuits, and how they function C H A P T E 3 Learning Objectives A.C. Through esistance and Inductance Power Factor Active and eactive Components of Circuit Current-I Active, eactive and Apparent Power Q-factor of a Coil Power in an

More information

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY WN U-60 Attachment C to Schedule 152, Page 1 SCHEDULE 152 APPLICATION FOR INTERCONNECTING A GENERATING FACILITY TIER 2 OR TIER 3 This Application is considered complete when it provides all applicable

More information

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03 Multimeter 560CVD03 Without LCD Display There are several versions available: With LCD Display Figure 1 Type Display LO HI 1A 5A Versions R0031 3U3I x x x R0035 3U3I x x x R0051 3U3I x x x R0055 3U3I x

More information

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre. General PQ: Power Quality has multiple issues involved. Thus, need to have some benchmarking standards. Very little is spoken about the LT supply installation within an industry. There is need to understand

More information

10kW Three-phase SiC PFC Rectifier

10kW Three-phase SiC PFC Rectifier www.onsemi.com 10kW Three-phase SiC PFC Rectifier SEMICON EUROPA, Nov 13-18, 2018, Munich, Germany Contents General PFC Concept 3 Phase System and PFC Control Simulation Understanding the losses 3 Phase

More information

Power Factor Correction Input Circuit

Power Factor Correction Input Circuit Power Factor Correction Input Circuit Written Proposal Paul Glaze, Kevin Wong, Ethan Hotchkiss, Jethro Baliao November 2, 2016 Abstract We are to design and build a circuit that will improve power factor

More information

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE Experiment 45 Three-Phase Circuits OBJECTIVE To study the relationship between voltage and current in three-phase circuits. To learn how to make delta and wye connections. To calculate the power in three-phase

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information