1 R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

2 Leakage inductances + v 1 (t) i 1 (t) Φ l1 Φ M Φ l2 i 2 (t) + v 2 (t) Φ l1 Φ l2 i 1 (t) + v 1 (t) Φ M i 2 (t) + v 2 (t) 33

3 Transformer model, including leakage inductance Terminal equations can be written in the form v 1 (t) v 2 (t) = L 11 L 12 L 12 L 22 d dt i 1 (t) i 2 (t) + v 1 L l1 i 1 n 1 : n 2 i 2 L M = n 1 n 2 L 12 i M L l2 + v 2 mutual inductance: Ideal L 12 = n 1n 2 R = n 2 n 1 L M primary and secondary self-inductances: effective turns ratio n e = L 22 L 11 L 11 = L l1 + n 1 n 2 L 12 L 22 = L l2 + n 2 n 1 L 12 coupling coefficient k = L 12 L 11 L 22 34

4

5 13.3 Loss mechanisms in magnetic devices Low-frequency losses: Dc copper loss Core loss: hysteresis loss High-frequency losses: the skin effect Core loss: classical eddy current losses Eddy current losses in ferrite cores High frequency copper loss: the proximity effect Proximity effect: high frequency limit MMF diagrams, losses in a layer, and losses in basic multilayer windings Effect of PWM waveform harmonics 35

6 Core loss Energy per cycle W flowing into n- turn winding of an inductor, excited by periodic waveforms of frequency f: W = one cycle v(t)i(t)dt i(t) + v(t) n turns Φ core Core area A c Core permeability µ Relate winding voltage and current to core B and H via Faraday s law and Ampere s law: db(t) v(t)=na c dt H(t)l m = ni(t) Substitute into integral: W = one cycle db(t) na c dt = A c l m H db 36 one cycle H(t)l m n dt

7 Core loss: Hysteresis loss W = A c l m one cycle H db B Area one cycle H db The term A c l m is the volume of the core, while the integral is the area of the B H loop. H (energy lost per cycle) = (core volume) (area of B H loop) P H = f A c l m H db one cycle Hysteresis loss is directly proportional to applied frequency 37

8 Modeling hysteresis loss Hysteresis loss varies directly with applied frequency Dependence on maximum flux density: how does area of B H loop depend on maximum flux density (and on applied waveforms)? Empirical equation (Steinmetz equation): P H = K H fb α max (core volume) The parameters K H and are determined experimentally. Dependence of P H on B max is predicted by the theory of magnetic domains. 38

9 Core loss: eddy current loss Magnetic core materials are reasonably good conductors of electric current. Hence, according to Lenz s law, magnetic fields within the core induce currents ( eddy currents ) to flow within the core. The eddy currents flow such that they tend to generate a flux which opposes changes in the core flux (t). The eddy currents tend to prevent flux from penetrating the core. Flux Φ(t) Eddy current i(t) Core Eddy current loss i 2 (t)r 39

10 Modeling eddy current loss Ac flux (t) induces voltage v(t) in core, according to Faraday s law. Induced voltage is proportional to derivative of (t). In consequence, magnitude of induced voltage is directly proportional to excitation frequency f. If core material impedance Z is purely resistive and independent of frequency, Z = R, then eddy current magnitude is proportional to voltage: i(t) = v(t)/r. Hence magnitude of i(t) is directly proportional to excitation frequency f. Eddy current power loss i 2 (t)r then varies with square of excitation frequency f. Classical Steinmetz equation for eddy current loss: P E = K E f 2 2 B max (core volume) Ferrite core material impedance is capacitive. This causes eddy current power loss to increase as f 4. 40

11 Total core loss: manufacturer s data Ferrite core material 1 1MHz 500kHz 200kHz Empirical equation, at a fixed frequency: Power loss density, Watts/cm kHz 50kHz 20kHz P fe = K fe ( B) β A c l m B, Tesla 41

12 Core materials Core type B sat Relative core loss Applications Laminations iron, silicon steel Powdered cores powdered iron, molypermalloy Ferrite Manganese-zinc, Nickel-zinc T high Hz transformers, inductors T medium 1 khz transformers, 100 khz filter inductors T low 20 khz - 1 MHz transformers, ac inductors 42

13 Low-frequency copper loss DC resistance of wire R = ρ l b A w where A w is the wire bare cross-sectional area, and l b is the length of the wire. The resistivity is equal to cm for soft-annealed copper at room temperature. This resistivity increases to cm at 100 C. i(t) R The wire resistance leads to a power loss of 2 P cu = I rms R 43

14 13.4 Eddy currents in winding conductors Intro to the skin and proximity effects Wire Φ(t) Current density i(t) Eddy currents Wire δ i(t) Eddy currents 44

15 Penetration depth For sinusoidal currents: current density is an exponentially decaying function of distance into the conductor, with characteristic length known as the penetration depth or skin depth. Penetration depth δ, cm 0.1 Wire diameter #20 AWG δ = ρ πµ f C 25 C #30 AWG #40 AWG For copper at room temperature: δ = 7.5 f cm khz 100 khz 1 MHz Frequency 45

16 The proximity effect Ac current in a conductor induces eddy currents in adjacent conductors by a process called the proximity effect. This causes significant power loss in the windings of high-frequency transformers and ac inductors. A multi-layer foil winding, with h >. Each layer carries net current i(t). Current density J iconductor 1 h Area Φ Conductor 2 i i i Area i Area i 46

17 Example: a two-winding transformer Cross-sectional view of two-winding transformer example. Primary turns are wound in three layers. For this example, let s assume that each layer is one turn of a flat foil conductor. The secondary is a similar three-layer winding. Each layer carries net current i(t). Portions of the windings that lie outside of the core window are not illustrated. Each layer has thickness h >. Core i i i { Layer 1 Layer 2 Layer 3 Primary winding i i i Layer 3 { Layer 2 Layer 1 Secondary winding 47

18 Distribution of currents on surfaces of conductors: two-winding example Skin effect causes currents to concentrate on surfaces of conductors Surface current induces equal and opposite current on adjacent conductor This induced current returns on opposite side of conductor Net conductor current is equal to i(t) for each layer, since layers are connected in series Circulating currents within layers increase with the numbers of layers Core Current density J Layer 1 h Layer 1 i i i Layer 2 Primary winding 48 Layer 3 i i i Layer 3 Layer 2 Φ 2Φ 3Φ 2Φ Φ i i 2i 2i 3i 3i 2i 2i i i Layer 2 Layer 3 Layer 3 Layer 2 Layer 1 Layer 1 Secondary winding

19 Estimating proximity loss: high-frequency limit The current i(t) having rms value I is confined to thickness d on the surface of layer 1. Hence the effective ac resistance of layer 1 is: R ac = h δ R dc This induces copper loss P 1 in layer 1: P 1 = I 2 R ac Power loss P 2 in layer 2 is: P 2 = P 1 +4P 1 =5P 1 Power loss P 3 in layer 3 is: Current density J h Layer 1 Φ 2Φ 3Φ 2Φ Φ i i 2i 2i 3i 3i 2i 2i i i Layer 2 Primary winding Layer 3 Layer 3 Layer 2 Secondary winding Power loss P m in layer m is: Layer 1 P 3 = P 1 = 13P 1 P m = I 2 m m 2 h δ R dc 49

20 Total loss in M-layer winding: high-frequency limit Add up losses in each layer: Μ Σ P = I 2 h δ R dc m m 2 m =1 = I 2 h δ R M dc 2M Compare with dc copper loss: If foil thickness were H =, then at dc each layer would produce copper loss P 1. The copper loss of the M-layer winding would be P dc = I 2 MR dc So the proximity effect increases the copper loss by a factor of F R = P P dc = 1 3 h δ 2M

21 Leakage flux in windings A simple two-winding transformer example: core and winding geometry Each turn carries net current i(t) in direction shown Primary winding { Secondary winding { y x Core µ > µ 0 51

22 Flux distribution Mutual flux M is large and is mostly confined to the core Leakage flux is present, which does not completely link both windings Because of symmetry of winding geometry, leakage flux runs approximately vertically through the windings Leakage flux Mutual flux Φ M 52

23 Analysis of leakage flux using Ampere s law Ampere s law, for the closed path taken by the leakage flux line illustrated: Leakage path Enclosed current = F(x)=H(x)l w (note that MMF around core is small compared to MMF through the air inside the winding, because of high permeability of core) Enclosed current H(x) + F(x) l w x 53

24 Ampere s law for the transformer example For the innermost leakage path, enclosing the first layer of the primary: This path encloses four turns, so the total enclosed current is 4i(t). For the next leakage path, enclosing both layers of the primary: This path encloses eight turns, so the total enclosed current is 8i(t). The next leakage path encloses the primary plus four turns of the secondary. The total enclosed current is 8i(t) 4i(t) = 4i(t). Leakage flux Mutual flux Φ M 54

25 MMF diagram, transformer example MMF F(x) across the core window, as a function of position x Enclosed current = F(x)=H(x)l w Leakage path Primary winding { Layer 1 Layer 2 Secondary winding { Layer 2 Layer 1 Enclosed current F(x) l w F(x) 8i H(x) + 4i x 0 x 55

26 Two-winding transformer example Winding layout Core i i i i i i Layer 1 Layer 2 Layer 3 Layer 3 Layer 2 Layer 1 MMF diagram Use Ampere s law around a closed path taken by a leakage flux line: m p m s i = F(x) m p = number of primary layers enclosed by path m s = number of secondary layers enclosed by path MMF F(x) 3i 2i i 0 i i i i i i x 56

27 Two-winding transformer example with proximity effect Flux does not penetrate conductors Surface currents cause net current enclosed by leakage path to be zero when path runs down interior of a conductor Magnetic field strength H(x) within the winding is given by H(x)= F(x) l w MMF F(x) 3i 2i i 0 i i 2i 2i 3i 3i 2i 2i i i x 57

28 Interleaving the windings: MMF diagram pri sec pri sec pri sec MMF F(x) i i i i i i 3i 2i i 0 x Greatly reduces the peak MMF, leakage flux, and proximity losses 58

29 A partially-interleaved transformer For this example, there are three primary layers and four secondary layers. The MMF diagram contains fractional values. MMF F(x) 1.5 i i 0.5 i i i 1.5 i Secondary 3i 4 m = 1 3i 4 m = 2 Primary i i i 3i 4 m = 1.5 m = 0.5 m = 1.5 Secondary m = 2 3i 4 m = 1 x 59

30 Foil windings and layers d Approximating a layer of round conductors as an effective single foil conductor: (a) (b) (c) (d) h h h l w Square conductors (b) have same crosssectional area as round conductors (a) if h = π 4 d Eliminate space between square conductors: push together into a single foil turn (c) (d) Stretch foil so its width is l w. The adjust conductivity so its dc resistance is unchanged 60

31 Winding porosity Stretching the conductor increases its area. Compensate by increasing the effective resistivity, to maintain the same dc resistance. Define winding porosity as the ratio of cross-sectional areas. If layer of width l w contains n l turns of round wire having diameter d, then the porosity is (c) h (d) h η = π 4 d n l l w Typical for full-width round conductors is = 0.8. The increased effective resistivity increases the effective skin depth: δ = δ η l w Define = h/d. The effective value for a layer of round conductors is ϕ = h δ = η π 4 d δ 61

32 Power loss in a layer Approximate computation of copper loss in one layer Assume uniform magnetic fields at surfaces of layer, of strengths H(0) and H(h). Assume that these fields are parallel to layer surface (i.e., neglect fringing and assume field normal component is zero). H(0) Layer H(h) The magnetic fields H(0) and H(h) are driven by the MMFs F(0) and F(h). Sinusoidal waveforms are assumed, and rms values are used. It is assumed that H(0) and H(h) are in phase. F(x) F(0) F(h) 0 h 62

33 Solution for layer copper loss P Solve Maxwell s equations to find current density distribution within layer. Then integrate to find total copper loss P in layer. Result is P = R dc ϕ n l 2 F 2 (h)+f 2 (0) G 1 (ϕ) 4F(h)F(0)G 2 (ϕ) where R dc = ρ l b = ρ (MLT)n 3 l A w G 1 (ϕ)= ηl w 2 sinh(2ϕ) +sin (2ϕ) cosh (2ϕ) cos (2ϕ) n l = number of turns in layer, R dc = dc resistance of layer, (MLT) = mean-length-per-turn, or circumference, of layer. G 2 (ϕ)= sinh (ϕ) cos (ϕ)+cosh (ϕ) sin (ϕ) cosh (2ϕ) cos (2ϕ) ϕ = h δ = η π 4 d δ η = π 4 d n l l w 63

34 Winding carrying current I, with n l turns per layer If winding carries current of rms magnitude I, then F(h) F(0) = n l I Express F(h) in terms of the winding current I, as F(h)=mn l I H(0) Layer H(h) The quantity m is the ratio of the MMF F(h) to the layer ampere-turns n l I. Then, F(0) F(h) = m m 1 Power dissipated in the layer can now be written P = I 2 R dc ϕq (ϕ, m) F(x) F(0) F(h) Q (ϕ, m)= 2m 2 2m +1 G 1 (ϕ) 4mm 1 G 2 (ϕ) 0 h 64

35 Increased copper loss in layer P = I 2 R dc ϕq (ϕ, m) 100 m = P I 2 R dc m = ϕ 65

36 Layer copper loss vs. layer thickness P P dc ϕ =1 = Q (ϕ, m) P P dc ϕ =1 100 m = Relative to copper loss when h = m = ϕ 66

37 Example: Power loss in a transformer winding Two winding transformer Each winding consists of M layers Proximity effect increases copper loss in layer m by the factor Q (,m) Sum losses over all primary layers: F R = P pri P pri,dc = 1 M M Σ m =1 F Mn p i 2n p i n p i 0 ϕq (ϕ, m) Primary layers Secondary layers { { n p i n p i n p i n p i n p i n p i m = 1 m = 2 m = M m = M m = 2 m = 1 x 67

38 Express summation in closed form: Increased total winding loss F R = ϕ G 1 (ϕ)+ 2 3 M 2 1 G 1 (ϕ) 2G 2 (ϕ) 100 Number of layers M = F R = P pri P pri,dc ϕ 68

39 Total winding loss P pri P pri,dc ϕ =1 = G 1 (ϕ)+ 2 3 M 2 1 G 1 (ϕ) 2G 2 (ϕ) P pri P pri,dc ϕ = Number of layers M = ϕ 69

40 Interleaving the windings Same transformer example, but with primary and secondary layers alternated Each layer operates with F = 0 on one side, and F = i on the other side Proximity loss of entire winding follows M = 1 curve MMF F(x) 3i 2i i 0 pri sec pri sec pri sec i i i i i i For M = 1: minimum loss occurs with = /2, although copper loss is nearly constant for any 1, and is approximately equal to the dc copper loss obtained when = 1. x 70

41 Partial interleaving Partially-interleaved example with 3 primary and 4 secondary layers Each primary layer carries current i while each secondary layer carries 0.75i. Total winding currents add to zero. Peak MMF occurs in space between windings, but has value 1.5i. MMF F(x) 1.5 i i 0.5 i i i 1.5 i Secondary 3i 4 m = 1 3i 4 m = 2 Primary i i i 3i 4 m = 1.5 m = 0.5 m = 1.5 Secondary m = 2 3i 4 m = 1 x We can apply the previous solution for the copper loss in each layer, and add the results to find the total winding losses. To determine the value of m to use for a given layer, evaluate F(h) m = F(h) F(0) 71

42 Determination of m m = m = m = m = Leftmost secondary layer: F(h) F(h) F(0) = 0.75i 0.75i 0 =1 Next secondary layer: F(h) F(h) F(0) = 1.5i 1.5i ( 0.75i) = 2 Next layer (primary): F(0) F(0) F(h) = 1.5i 1.5i ( 0.5i) = 1.5 Center layer (primary): MMF F(x) 1.5 i i 0.5 i i i 1.5 i Secondary 3i 4 m = 1 3i 4 m = 2 Primary i i i 3i 4 m = 1.5 m = 0.5 m = 1.5 Secondary F(h) F(h) F(0) = 0.5i 0.5i ( 0.5i) = 0.5 Use the plot for layer loss (repeated on next slide) to find loss for each layer, according to its value of m. Add results to find total loss. m = 2 3i 4 m = 1 x 72

43 Layer copper loss vs. layer thickness P P dc ϕ =1 = Q (ϕ, m) P P dc ϕ =1 100 m = Relative to copper loss when h = m = ϕ 73

44 Discussion: design of winding geometry to minimize proximity loss Interleaving windings can significantly reduce the proximity loss when the winding currents are in phase, such as in the transformers of buckderived converters or other converters In some converters (such as flyback or SEPIC) the winding currents are out of phase. Interleaving then does little to reduce the peak MMF and proximity loss. See Vandelac and Ziogas [10]. For sinusoidal winding currents, there is an optimal conductor thickness near = 1 that minimizes copper loss. Minimize the number of layers. Use a core geometry that maximizes the width l w of windings. Minimize the amount of copper in vicinity of high MMF portions of the windings 74

45 Litz wire A way to increase conductor area while maintaining low proximity losses Many strands of small-gauge wire are bundled together and are externally connected in parallel Strands are twisted, or transposed, so that each strand passes equally through each position on inside and outside of bundle. This prevents circulation of currents between strands. Strand diameter should be sufficiently smaller than skin depth The Litz wire bundle itself is composed of multiple layers Advantage: when properly sized, can significantly reduce proximity loss Disadvantage: increased cost and decreased amount of copper within core window 75

46 PWM waveform harmonics Fourier series: with i(t)=i 0 + Σ j =1 2 I j cos (jωt) i(t) I pk I j = 2 I pk jπ sin (jπd) I 0 = DI pk Copper loss: 0 DT s T s t Dc P dc = I 0 2 R dc Ac P j = I j 2 R dc j ϕ 1 G 1 ( j ϕ 1 )+ 2 3 M 2 1 G 1 ( j ϕ 1 ) 2G 2 ( j ϕ 1 ) Total, relative to value predicted by low-frequency analysis: P cu DI pk 2 = D + 2ϕ 1 R dc Dπ 2 Σ j =1 sin 2 (jπd) j j G 1 ( j ϕ 1 )+ 2 3 M 2 1 G 1 ( j ϕ 1 ) 2G 2 ( j ϕ 1 ) 76

47 Harmonic loss factor F H Effect of harmonics: F H = ratio of total ac copper loss to fundamental copper loss Σ P j j =1 F H = P 1 The total winding copper loss can then be written P cu = I 0 2 R dc + F H F R I 1 2 R dc 77

48 Increased proximity losses induced by PWM waveform harmonics: D = D = 0.5 M = 10 F H M = ϕ

49 Increased proximity losses induced by PWM waveform harmonics: D = 0.3 F H 100 D = M = M = ϕ 1 79

50 Increased proximity losses induced by PWM waveform harmonics: D = 0.1 F H M = 10 D = M = ϕ 1 80

51 Discussion: waveform harmonics Harmonic factor F H accounts for effects of harmonics Harmonics are most significant for 1 in the vicinity of 1 Harmonics can radically alter the conclusion regarding optimal wire gauge A substantial dc component can drive the design towards larger wire gauge Harmonics can increase proximity losses by orders of magnitude, when there are many layers and when 1 lies in the vicinity of 1 For sufficiently small 1, F H tends to the value 1 + (THD) 2, where the total harmonic distortion of the current is THD = Σ I j 2 j =2 I 1 81

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder 13.3.2 Low-frequency copper loss DC resistance of wire R = ρ l b A w where A w is the wire bare

More information

Inductor and Transformer Design

Inductor and Transformer Design Inductor and Transformer Design 1 Introduction The conditioning of power flow in Power Electronic Systems (PES) is done through the use of electromagnetic elements (inductors and transformers). In this

More information

Lecture 6 ECEN 4517/5517

Lecture 6 ECEN 4517/5517 Lecture 6 ECEN 4517/5517 Experiment 4: inverter system Battery 12 VDC HVDC: 120-200 VDC DC-DC converter Isolated flyback DC-AC inverter H-bridge v ac AC load 120 Vrms 60 Hz d d Feedback controller V ref

More information

Lecture 29 Total Losses in Magnetic Components, the Heat Flow Balance and Equilibrium Temperatures

Lecture 29 Total Losses in Magnetic Components, the Heat Flow Balance and Equilibrium Temperatures Lecture 29 Total Losses in Magnetic Components, the Heat Flow Balance and Equilibrium Temperatures 1 A. Review of Increased Loss in Transformer Wire Windings versus the wire parameter f and effective winding

More information

Designers Series XIII

Designers Series XIII Designers Series XIII 1 We have had many requests over the last few years to cover magnetics design in our magazine. It is a topic that we focus on for two full days in our design workshops, and it has

More information

Magnetics Design. Specification, Performance and Economics

Magnetics Design. Specification, Performance and Economics Magnetics Design Specification, Performance and Economics W H I T E P A P E R MAGNETICS DESIGN SPECIFICATION, PERFORMANCE AND ECONOMICS By Paul Castillo Applications Engineer Datatronics Introduction The

More information

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web: Version: January 16, 2017 What is an Inductor? Web: www.token.com.tw Email: rfq@token.com.tw Token Electronics Industry Co., Ltd. Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New Taipei City,

More information

West Coast Magnetics. Advancing Power Electronics FOIL WINDINGS FOR SMPS INDUCTORS AND TRANSFORMERS. Weyman Lundquist, CEO and Engineering Manager

West Coast Magnetics. Advancing Power Electronics FOIL WINDINGS FOR SMPS INDUCTORS AND TRANSFORMERS. Weyman Lundquist, CEO and Engineering Manager 1 West Coast Magnetics Advancing Power Electronics FOIL WINDINGS FOR SMPS INDUCTORS AND TRANSFORMERS Weyman Lundquist, CEO and Engineering Manager TYPES OF WINDINGS 2 Solid wire Lowest cost Low DC resistance

More information

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA HOME APPLICATION NOTES Iron Powder Core Selection For RF Power Applications Jim Cox Micrometals, Inc. Anaheim, CA Purpose: The purpose of this article is to present new information that will allow the

More information

Chapter 16: Mutual Inductance

Chapter 16: Mutual Inductance Chapter 16: Mutual Inductance Instructor: Jean-François MILLITHALER http://faculty.uml.edu/jeanfrancois_millithaler/funelec/spring2017 Slide 1 Mutual Inductance When two coils are placed close to each

More information

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12) DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE 6401 ELECTRICAL MACHINES I UNIT I : MAGNETIC CIRCUITS AND MAGNETIC MATERIALS Part A (2 Marks) 1. List

More information

Magnetics. Important relationships. Magnetic quantities Analogies to electrical quantities

Magnetics. Important relationships. Magnetic quantities Analogies to electrical quantities Mor M. Peretz, Switch-Mode Power Supplies [3-1] Faraday s and Amper s laws Permeability Inductor Reluctance model Air gap Current crowding Inductor design Skin effect, proximity effect Losses Transformer

More information

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer Walchand Institute of Technology Basic Electrical and Electronics Engineering Transformer 1. What is transformer? explain working principle of transformer. Electrical power transformer is a static device

More information

Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors

Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors Louis Diana Agenda Theory of operation and design equations Design flow diagram discussion Inductance calculations Ampere s law for magnetizing

More information

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES UNIVERSITY OF TECHNOLOGY DEPARTMENT OF ELECTRICAL ENGINEERING Year: Second 2016-2017 By: Fadhil A. Hasan ELECTRICAL MACHINES І Module-II: AC Transformers o Single phase transformers o Three-phase transformers

More information

HOME APPLICATION NOTES

HOME APPLICATION NOTES HOME APPLICATION NOTES INDUCTOR DESIGNS FOR HIGH FREQUENCIES Powdered Iron "Flux Paths" can Eliminate Eddy Current 'Gap Effect' Winding Losses INTRODUCTION by Bruce Carsten for: MICROMETALS, Inc. There

More information

Radio Frequency Electronics

Radio Frequency Electronics Radio Frequency Electronics Preliminaries II Guglielmo Giovanni Maria Marconi Thought off by many people as the inventor of radio Pioneer in long-distance radio communications Shared Nobel Prize in 1909

More information

CH 1. Large coil. Small coil. red. Function generator GND CH 2. black GND

CH 1. Large coil. Small coil. red. Function generator GND CH 2. black GND Experiment 6 Electromagnetic Induction "Concepts without factual content are empty; sense data without concepts are blind... The understanding cannot see. The senses cannot think. By their union only can

More information

STUDY AND DESIGN ASPECTS OF INDUCTORS FOR DC-DC CONVERTER

STUDY AND DESIGN ASPECTS OF INDUCTORS FOR DC-DC CONVERTER STUDY AND DESIGN ASPECTS OF INDUCTORS FOR DC-DC CONVERTER 1 Nithya Subramanian, 2 R. Seyezhai 1 UG Student, Department of EEE, SSN College of Engineering, Chennai 2 Associate Professor, Department of EEE,

More information

Evaluation and Design of High Frequency Transformers for On Board Charging Applications

Evaluation and Design of High Frequency Transformers for On Board Charging Applications Evaluation and Design of High Frequency Transformers for On Board Charging Applications Master s Thesis in Electrical Power Engineering TOBIAS ELGSTRÖM LINUS NORDGREN Department of Energy and Environment

More information

WELCOME TO THE LECTURE

WELCOME TO THE LECTURE WLCOM TO TH LCTUR ON TRNFORMR Single Phase Transformer Three Phase Transformer Transformer transformer is a stationary electric machine which transfers electrical energy (power) from one voltage level

More information

Accurate Models for Spiral Resonators

Accurate Models for Spiral Resonators MITSUBISHI ELECTRIC RESEARCH LABORATORIES http://www.merl.com Accurate Models for Spiral Resonators Ellstein, D.; Wang, B.; Teo, K.H. TR1-89 October 1 Abstract Analytically-based circuit models for two

More information

Glossary of Common Magnetic Terms

Glossary of Common Magnetic Terms Glossary of Common Magnetic Terms Copyright by Magnelab, Inc. 2009 Air Core A term used when no ferromagnetic core is used to obtain the required magnetic characteristics of a given coil. (see Core) Ampere

More information

Inductance in DC Circuits

Inductance in DC Circuits Inductance in DC Circuits Anurag Srivastava Concept: Inductance is characterized by the behavior of a coil of wire in resisting any change of electric current through the coil. Arising from Faraday's law,

More information

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved. Single-turn and multi-turn coil domains in 3D 2012 COMSOL. All rights reserved. Introduction This tutorial shows how to use the Single-Turn Coil Domain and Multi-Turn Coil Domain features in COMSOL s Magnetic

More information

29 th International Physics Olympiad

29 th International Physics Olympiad 29 th International Physics Olympiad Reykjavik, Iceland Experimental competition Monday, July 6th, 1998 Time available: 5 hours Read this first: Use only the pen provided. 1. Use only the front side of

More information

GLOSSARY OF TERMS FLUX DENSITY:

GLOSSARY OF TERMS FLUX DENSITY: ADSL: Asymmetrical Digital Subscriber Line. Technology used to transmit/receive data and audio using the pair copper telephone lines with speed up to 8 Mbps. AMBIENT TEMPERATURE: The temperature surrounding

More information

Department of Electrical and Computer Engineering Lab 6: Transformers

Department of Electrical and Computer Engineering Lab 6: Transformers ESE Electronics Laboratory A Department of Electrical and Computer Engineering 0 Lab 6: Transformers. Objectives ) Measure the frequency response of the transformer. ) Determine the input impedance of

More information

Challenges and Trends in Magnetics

Challenges and Trends in Magnetics Challenges and Trends in Magnetics Prof. W. G. Hurley Power Electronics Research Centre National University of Ireland, Galway IEEE Distinguished Lecture The University of Hong Kong 27 May 2016 Outline

More information

Transformers. gpmacademics.weebly.com

Transformers. gpmacademics.weebly.com TRANSFORMERS Syllabus: Principles of operation, Constructional Details, Losses and efficiency, Regulation of Transformer, Testing: OC & SC test. TRANSFORMER: It is a static device which transfers electric

More information

Optimizing Custom Magnetics for High-Performance Power Supplies

Optimizing Custom Magnetics for High-Performance Power Supplies Optimizing Custom Magnetics for High-Performance Power Supplies Michael Seeman, Ph.D. Founder / CEO. mike@eta1power.com April 2018 PELS Seminar 2018. Outline What is Power Supply Optimization? Performance

More information

LECTURE 26 Losses in Magnetic Devices

LECTURE 26 Losses in Magnetic Devices LECTURE 26 Losses in Magnetic Devices 1 Achieving acceptable loss levels in magnetic devices is the primary goal. A. Overview of Magnetic Device Losses B. Faraday s and Lenz s Law 1.B max in Cores from

More information

VOLTECHNOTES. Transformer Basics VPN /1

VOLTECHNOTES. Transformer Basics VPN /1 Transformer Basics VPN 104-039/1 TRANSFORMER BASICS Introduction Transformer design and test are sometimes viewed as an art rather than a science. Transformers are imperfect devices, and there will be

More information

Experiment 4: Grounding and Shielding

Experiment 4: Grounding and Shielding 4-1 Experiment 4: Grounding and Shielding Power System Hot (ed) Neutral (White) Hot (Black) 115V 115V 230V Ground (Green) Service Entrance Load Enclosure Figure 1 Typical residential or commercial AC power

More information

TRANSFORMER THEORY. Mutual Induction

TRANSFORMER THEORY. Mutual Induction Transformers Transformers are used extensively for AC power transmissions and for various control and indication circuits. Knowledge of the basic theory of how these components operate is necessary to

More information

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment) ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment) 1. In an A.C. circuit A ; the current leads the voltage by 30 0 and in circuit B, the current lags behind the voltage by 30 0. What is the

More information

PHYS 1442 Section 004 Lecture #15

PHYS 1442 Section 004 Lecture #15 PHYS 1442 Section 004 Lecture #15 Monday March 17, 2014 Dr. Andrew Brandt Chapter 21 Generator Transformer Inductance 3/17/2014 1 PHYS 1442-004, Dr. Andrew Brandt Announcements HW8 on Ch 21-22 will be

More information

Flyback transformer design considerations for efficiency and EMI

Flyback transformer design considerations for efficiency and EMI Flyback transformer design considerations for efficiency and EMI Isaac Cohen Bernard Keogh Agenda Flyback transformer basics Review of Flyback transformer losses: o Core loss dependence on DC bias, duty

More information

Transformers. Dr. Gamal Sowilam

Transformers. Dr. Gamal Sowilam Transformers Dr. Gamal Sowilam OBJECTIVES Become familiar with the flux linkages that exist between the coils of a transformer and how the voltages across the primary and secondary are established. Understand

More information

Inductors & Resonance

Inductors & Resonance Inductors & Resonance The Inductor This figure shows a conductor carrying a current. A magnetic field is set up around the conductor as concentric circles. If a coil of wire has a current flowing through

More information

PHYS 1444 Section 501 Lecture #20

PHYS 1444 Section 501 Lecture #20 PHYS 1444 Section 501 Lecture #0 Monday, Apr. 17, 006 Transformer Generalized Faraday s Law Inductance Mutual Inductance Self Inductance Inductor Energy Stored in the Magnetic Field 1 Announcements Quiz

More information

Exclusive Technology Feature. Leakage Inductance (Part 1): Friend Or Foe? The Underlying Physics. ISSUE: October 2015

Exclusive Technology Feature. Leakage Inductance (Part 1): Friend Or Foe? The Underlying Physics. ISSUE: October 2015 ISSUE: October 2015 Leakage Inductance (Part 1): Friend Or Foe? by Ernie Wittenbreder, Technical Witts, Flagstaff, Ariz There are situations in which leakage inductance in a transformer or coupled inductor

More information

APPLICATION NOTE - 018

APPLICATION NOTE - 018 APPLICATION NOTE - 018 Power Transformers Background Power Transformers are used within an AC power distribution systems to increase or decrease the operating voltage to achieve the optimum transmission

More information

Chapter 2-1 Transformers

Chapter 2-1 Transformers Principles of Electric Machines and Power Electronics Chapter 2-1 Transformers Third Edition P. C. Sen Transformer application 1: power transmission Ideal Transformer Assumptions: 1. Negligible winding

More information

Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc.

Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc. HOME APPLICATION NOTES Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc. SUBJECT: A brief overview will be given of the development of carbonyl iron powders. We will show how the magnetic

More information

total j = BA, [1] = j [2] total

total j = BA, [1] = j [2] total Name: S.N.: Experiment 2 INDUCTANCE AND LR CIRCUITS SECTION: PARTNER: DATE: Objectives Estimate the inductance of the solenoid used for this experiment from the formula for a very long, thin, tightly wound

More information

By Gill ( ) PDF created with FinePrint pdffactory trial version

By Gill (  ) PDF created with FinePrint pdffactory trial version By Gill (www.angelfire.com/al4/gill ) 1 Introduction One of the main reasons of adopting a.c. system instead of d.c. for generation, transmission and distribution of electrical power is that alternatin

More information

Large Kool Mµ Core Shapes

Large Kool Mµ Core Shapes Large Kool Mµ Core Shapes TECHNICAL BULLETIN Ideal for high current inductors, large Kool Mµ geometries (E cores, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss, excellent

More information

LEAKAGE FLUX CONSIDERATIONS ON KOOL Mµ E CORES

LEAKAGE FLUX CONSIDERATIONS ON KOOL Mµ E CORES LEAKAGE FLUX CONSIDERATIONS ON E CORES Michael W. Horgan Senior Applications Engineer Magnetics Division of Spang & Co. Butler, PA 163 Abstract Kool Mu, a Silicon-Aluminum-Iron powder, is a popular soft

More information

Renco Electronics, Inc.

Renco Electronics, Inc. Abstract The operating frequency of most electronic circuits has been increasing since the late 1950 s. While the increase in frequency has reduced the overall weight and size of most consumer electronics

More information

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER PRODUCT RANGE POWER INDUCTORS Toroidal technology, driven by 20 years of R&D. POWER TRANSFORMERS

More information

Chapter 33. Alternating Current Circuits

Chapter 33. Alternating Current Circuits Chapter 33 Alternating Current Circuits C HAP T E O UTLI N E 33 1 AC Sources 33 2 esistors in an AC Circuit 33 3 Inductors in an AC Circuit 33 4 Capacitors in an AC Circuit 33 5 The L Series Circuit 33

More information

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION The use of giant magnetoresistive

More information

Achieving High Power Density Designs in DC-DC Converters

Achieving High Power Density Designs in DC-DC Converters Achieving High Power Density Designs in DC-DC Converters Agenda Marketing / Product Requirement Design Decision Making Translating Requirements to Specifications Passive Losses Active Losses Layout / Thermal

More information

Large Kool Mµ Core Shapes

Large Kool Mµ Core Shapes Large Kool Mµ Core Shapes TECHNICAL BULLETIN Ideal for high current inductors, large Kool Mµ geometries (E cores, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss, excellent

More information

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1 Chapter 8: Cable Modeling Related to the topic in section 8.14, sometimes when an RF transmitter is connected to an unbalanced antenna fed against earth ground

More information

A Fresh Look at Design of Buck and Boost inductors for SMPS Converters

A Fresh Look at Design of Buck and Boost inductors for SMPS Converters A Fresh Look at Design of Buck and Boost inductors for SMPS Converters Authors: Weyman Lundquist, Carl Castro, both employees of West Coast Magnetics. Inductors are a critical component in buck and boost

More information

Experiment 5: Grounding and Shielding

Experiment 5: Grounding and Shielding Experiment 5: Grounding and Shielding Power System Hot (Red) Neutral (White) Hot (Black) 115V 115V 230V Ground (Green) Service Entrance Load Enclosure Figure 1 Typical residential or commercial AC power

More information

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017 PHYS 1441 Section 001 Lecture #22 Chapter 29:EM Induction & Faraday s Law Transformer Electric Field Due to Changing Magnetic Flux Chapter 30: Inductance Mutual and Self Inductance Energy Stored in Magnetic

More information

HIGHER power inductors with broad current spectra

HIGHER power inductors with broad current spectra 202 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 1, JANUARY 1998 Inductor Design for High-Power Applications with Broad-Spectrum Excitation Ian T. Wallace, Nasser H. Kutkut, Member, IEEE, Subhashish

More information

Switching Frequency and Efficiency: A Complex Relationship

Switching Frequency and Efficiency: A Complex Relationship Switching Frequency and Efficiency: A Complex Relationship By Andrew Smith Senior Product Marketing Manager Power Integrations Power supply designers can increase efficiency while moving to a higher switching

More information

Electrical Theory 2 Lessons for Fall Semester:

Electrical Theory 2 Lessons for Fall Semester: Electrical Theory 2 Lessons for Fall Semester: Lesson 1 Magnetism Lesson 2 Introduction to AC Theory Lesson 3 Lesson 4 Capacitance and Capacitive Reactance Lesson 5 Impedance and AC Circuits Lesson 6 AC

More information

Selecting Magnetics for High Frequency Converters Practical Hints and Suggestions for Getting Started. Industry Session on Magnetics APEC 2016

Selecting Magnetics for High Frequency Converters Practical Hints and Suggestions for Getting Started. Industry Session on Magnetics APEC 2016 Practical Hints and Suggestions for Getting Started Industry Session on Magnetics APEC 2016 The Challenge: Hypothetically, a small- to medium-sized power converter manufacturer with limited resources is

More information

PHYSICS WORKSHEET CLASS : XII. Topic: Alternating current

PHYSICS WORKSHEET CLASS : XII. Topic: Alternating current PHYSICS WORKSHEET CLASS : XII Topic: Alternating current 1. What is mean by root mean square value of alternating current? 2. Distinguish between the terms effective value and peak value of an alternating

More information

15. the power factor of an a.c circuit is.5 what will be the phase difference between voltage and current in this

15. the power factor of an a.c circuit is.5 what will be the phase difference between voltage and current in this 1 1. In a series LCR circuit the voltage across inductor, a capacitor and a resistor are 30 V, 30 V and 60 V respectively. What is the phase difference between applied voltage and current in the circuit?

More information

Calculation of AC Losses of Storage Inductors in DC/DC converters

Calculation of AC Losses of Storage Inductors in DC/DC converters Calculation of AC Losses of Storage Inductors in DC/DC converters Lorandt Fölkel M.Eng Business Development Manager & Field Application Engineer Table of Contents Introduction Estimation of losses(classical

More information

1. If the flux associated with a coil varies at the rate of 1 weber/min,the induced emf is

1. If the flux associated with a coil varies at the rate of 1 weber/min,the induced emf is 1. f the flux associated with a coil varies at the rate of 1 weber/min,the induced emf is 1 1. 1V 2. V 60 3. 60V 4. Zero 2. Lenz s law is the consequence of the law of conservation of 1. Charge 2. Mass

More information

Optimized shield design for reduction of EMF from wireless power transfer systems

Optimized shield design for reduction of EMF from wireless power transfer systems This article has been accepted and published on J-STAGE in advance of copyediting. Content is final as presented. IEICE Electronics Express, Vol.*, No.*, 1 9 Optimized shield design for reduction of EMF

More information

GeckoMAGNETICS Modeling Inductive Components

GeckoMAGNETICS Modeling Inductive Components GeckoMAGNETICS is a tool that enables fast, accurate and user-friendly modelling and pareto-optimal design of inductive power components. 4) A material and core database (GeckoDB), which is a part of the

More information

Analysis and Design of a 500 W DC Transformer

Analysis and Design of a 500 W DC Transformer University of Colorado, Boulder CU Scholar Electrical, Computer & Energy Engineering Graduate Theses & Dissertations Electrical, Computer & Energy Engineering Spring 1-1-2014 Analysis and Design of a 500

More information

Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences

Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences Comparison of Lamination Iron Losses Supplied by PWM Voltages: US and European Experiences A. Boglietti, IEEE Member, A. Cavagnino, IEEE Member, T. L. Mthombeni, IEEE Student Member, P. Pillay, IEEE Fellow

More information

Planar Magnetics Design For Low-voltage Dc-dc Converters

Planar Magnetics Design For Low-voltage Dc-dc Converters University of Central Florida Electronic Theses and Dissertations Masters Thesis (Open Access) Planar Magnetics Design For Low-voltage Dc-dc Converters 2004 Shangyang Xiao University of Central Florida

More information

Large Kool Mµ Core Shapes

Large Kool Mµ Core Shapes Large Kool Mµ Core Shapes Technical Bulletin Ideal for high current inductors, large Kool Mµ geometries (E cores, Toroids, U Cores and Blocks) offer all the advantages of Kool Mµ material, low core loss,

More information

CHAPTER 2. Transformers. Dr Gamal Sowilam

CHAPTER 2. Transformers. Dr Gamal Sowilam CHAPTER Transformers Dr Gamal Sowilam Introduction A transformer is a static machine. It is not an energy conversion device, it is indispensable in many energy conversion systems. A transformer essentially

More information

PHYS 1444 Section 003 Lecture #19

PHYS 1444 Section 003 Lecture #19 PHYS 1444 Section 003 Lecture #19 Monday, Nov. 14, 2005 Electric Generators DC Generator Eddy Currents Transformer Mutual Inductance Today s homework is homework #10, due noon, next Tuesday!! 1 Announcements

More information

Outcomes from this session

Outcomes from this session Outcomes from this session At the end of this session you should be able to Understand what is meant by the term losses. Iron Losses There are three types of iron losses Eddy current losses Hysteresis

More information

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers Department of Electrical Engineering Lecture Basic Operating Principles of Transformers In this Lecture Basic operating principles of following transformers are introduced Single-phase Transformers Three-phase

More information

Transformers. ELG3311: Habash,

Transformers. ELG3311: Habash, Transformers A transformer is a device that changes AC electric power at one voltage level to AC electric power at another voltage level through the action of magnetic field. t consists of two or more

More information

Finite Element Analysis (FEA) software. Magnetic component design. 3D Electromagnetic Simulation Allows Reduction of AC Copper Losses

Finite Element Analysis (FEA) software. Magnetic component design. 3D Electromagnetic Simulation Allows Reduction of AC Copper Losses ABSTRACT AC currents in multiple layers in the transformer window can increase copper losses significantly due to the proximity effect. Traditionally used Dowell s curves show that the phenomenon starts

More information

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

FGJTCFWPKPUVKVWVGQHVGEJPQNQI[ FGRCTVOGPVQHGNGEVTKECNGPIKPGGTKPI VGG246JKIJXQNVCIGGPIKPGGTKPI FGJTFWP"KPUKWG"QH"GEJPQNQI[" FGRTOGP"QH"GNGETKEN"GPIKPGGTKPI" GG"46"JKIJ"XQNIG"GPIKPGGTKPI Resonant Transformers: The fig. (b) shows the equivalent circuit of a high voltage testing transformer (shown

More information

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit CHAPTER 2 Basic Concepts, Three-Phase Review, and Per Unit 1 AC power versus DC power DC system: - Power delivered to the load does not fluctuate. - If the transmission line is long power is lost in the

More information

Name: Lab Partner: Section: The purpose of this lab is to study induction. Faraday s law of induction and Lenz s law will be explored. B = B A (8.

Name: Lab Partner: Section: The purpose of this lab is to study induction. Faraday s law of induction and Lenz s law will be explored. B = B A (8. Chapter 8 Induction - Faraday s Law Name: Lab Partner: Section: 8.1 Purpose The purpose of this lab is to study induction. Faraday s law of induction and Lenz s law will be explored. 8.2 Introduction It

More information

EE2022 Electrical Energy Systems

EE2022 Electrical Energy Systems EE0 Electrical Energy Systems Lecture : Transformer and Per Unit Analysis 7-0-0 Panida Jirutitijaroen Department of Electrical and Computer Engineering /9/0 EE0: Transformer and Per Unit Analysis by P.

More information

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Module 7. Transformer. Version 2 EE IIT, Kharagpur Module 7 Transformer Lesson 3 Ideal Transformer Contents 3 Ideal Transformer (Lesson: 3) 4 3. Goals of the lesson 4 3. Introduction.. 5 3.. Principle of operation.. 5 3.3 Ideal Transformer.. 6 3.3. Core

More information

Brown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER

Brown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER Brown University Department of Physics Physics 6 Spring 2006 1 Introduction A SIMPLE FLUXGATE MAGNETOMETER A simple fluxgate magnetometer can be constructed out available equipment in the lab. It can easily

More information

Design Considerations

Design Considerations Design Considerations Ferrite toroids provide an often convenient and very effective shape for many wide band, pulse and power transformers and inductors. The continuous magnetic path yields the highest

More information

SOME STUDIES ON HIGH FREQUENCY RESONANT INVERTER BASED INDUCTION HEATER AND THE CORRESPONDING CHOICE OF SECONDARY METALLIC OBJECTS

SOME STUDIES ON HIGH FREQUENCY RESONANT INVERTER BASED INDUCTION HEATER AND THE CORRESPONDING CHOICE OF SECONDARY METALLIC OBJECTS SOME STUDIES ON HIGH FREQUENCY RESONANT INVERTER BASED INDUCTION HEATER AND THE CORRESPONDING CHOICE OF SECONDARY METALLIC OBJECTS ATANU BANDYOPADHYAY Reg.No-2010DR0139, dt-09.11.2010 Synopsis of Thesis

More information

A High Efficient Integrated Planar Transformer for Primary-Parallel Isolated Boost Converters

A High Efficient Integrated Planar Transformer for Primary-Parallel Isolated Boost Converters A High Efficient Integrated Planar Transformer for Primary-Parallel Isolated Boost Converters Gokhan Sen 1, Ziwei Ouyang 1, Ole C. Thomsen 1, Michael A. E. Andersen 1, and Lars Møller 2 1. Department of

More information

Waveforms for Stimulating Magnetic Cores

Waveforms for Stimulating Magnetic Cores Waveforms for Stimulating Magnetic Cores My assigned topic is test waveforms for magnetic cores, but I'm going to provide a little background, which touches on topics covered by other presenters here:

More information

13. Magnetically Coupled Circuits

13. Magnetically Coupled Circuits 13. Magnetically Coupled Circuits The change in the current flowing through an inductor induces (creates) a voltage in the conductor itself (self-inductance) and in any nearby conductors (mutual inductance)

More information

Basics of electrical transformer

Basics of electrical transformer Visit: https://engineeringbasic.com Complete basics and theory of Electrical Transformer Electrical Transformer is the most used electrical machine in power system. Both in the power transmission and distribution

More information

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101) Department of Electrical and Electronics Engineering Reg. No. : MNIPL INSTITUTE OF TECHNOLOGY, MNIPL ( Constituent Institute of Manipal University, Manipal) FIRST SEMESTER B.E. DEGREE MKEUP EXMINTION (REVISED

More information

DESIGN AND TECHNOLOGY OF THE MAINS SINGLE PHASE, LOW POWER TRANSFORMER

DESIGN AND TECHNOLOGY OF THE MAINS SINGLE PHASE, LOW POWER TRANSFORMER ANNEX A6* DESIGN AND TECHNOLOGY OF THE MAINS SINGLE PHASE, LOW POWER TRANSFORMER A6.1 Generalities This presentation aims to help in knowing the constructive structure, the manufacturing technology, as

More information

Chapter 2. Inductor Design for RFIC Applications

Chapter 2. Inductor Design for RFIC Applications Chapter 2 Inductor Design for RFIC Applications 2.1 Introduction A current carrying conductor generates magnetic field and a changing current generates changing magnetic field. According to Faraday s laws

More information

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION Nondestructive

More information

Windings for High Frequency

Windings for High Frequency Windings for High Frequency Charles R. Sullivan chrs@dartmouth.edu Dartmouth Magnetics and Power Electronics Research Group http://power.engineering.dartmouth.edu 1 The Issue The best-available technology

More information

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses: TUNED AMPLIFIERS 5.1 Introduction: To amplify the selective range of frequencies, the resistive load R C is replaced by a tuned circuit. The tuned circuit is capable of amplifying a signal over a narrow

More information

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon:

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon: In this lecture Electromagnetism Electromagnetic Effect Electromagnets Electromechanical Devices Transformers Electromagnetic Effect Electricity & magnetism are different aspects of the same basic phenomenon:

More information

Electrical Engineering / Electromagnetics

Electrical Engineering / Electromagnetics Electrical Engineering / Electromagnetics. Plot voltage versus time and current versus time for the circuit with the following substitutions: A. esistor B. Capacitor C. Inductor t = 0 A/B/C A. I t t B.

More information

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by This is a study guide for Exam 4. You are expected to understand and be able to answer mathematical questions on the following topics. Chapter 32 Self-Induction and Induction While a battery creates an

More information