1 RF Wireless Version On/off Control HC08V/RF + HC0RF Loop in 8 hours Detection Pattern 0 /88 / 5 /95 MHz Ambient daylight threshold Loop out manual on Condominium control 5s~0min ~50Lux Rotary coding switch(tx) Stand-by period Rotary coding switch(rx) RF antenna Antenna module RF antenna Stand-by dimming level Brightness on RF signal LED indication -0V Push Rotary coding switch HC08V/RF HC0RF RF Transmitter RF Receiver Hytronik Microwave motion sensor 50

2 This is a combination of motion sensor and RF wireless transmission. The motion detected by the unit HC08V/RF can pass onto other pre-defined individuals (the units) though RF transmission. Thanks to fixed address coding technology, it is easy to set up transmission groups. Up to different groups can be created by using the rotary coding switch. The transmission can reach 0 meters indoor and 00 meters in the open area. Digital receiving and transmitting method, high anti-interference capability. Optional transmission frequency of /88/5/95 MHz, thanks to FSK technology. RF Grouping (max. channels) Thanks to fixed address coding system, the setup of communication channel and the definition of s and s can be easily achieved by the rotary coding switch -- ( the transmitter unit is called, and the receiving unit called ). Using a screwdriver to adjust the rotary switch on both the & unit, to keep them pointing at the same channel, the grouping is then automatically completed. channels (max. groups) available for both the & unit. Using a screwdriver to point the arrow to the same position on the unit and units. Function and Options RF Transmitter (HC08V/RF) + RF Receiver (HC0RF), on-off function This is a combination of motion sensor and RF radio wireless transmission, which is the perfect solution for retrofit or carpark projects, easy installation and free of wiring. With fixed address coding system, by rotary coding switch method, selected and directional communication can be easily setup. Once there is motion detected, the can trigger unlimited number of s as long as they are within the transmission range. The unit can respond to unlimited numbers of s respectively. With sufficient nature light, the sensor is not triggered by motion. With insufficient nature light, the sensor is triggered by motion, the switches on all salves (unlimited) by RF signal. After the hold time, sensor switches off the whole group of lamps automatically if no movement is detected. Even in case, the (HC0RF) fails to receive the off signal from the, it will also switch off automatically after a 0sec time delay. 5 Hytronik Microwave motion sensor

3 Typical application for the staircase and corridor: HC0RF () HC08V/RF HC0RF () HC08V/RF While the st sensor detects motion on the st floor, it switches on and sends signal to all units. All HC0RF on the st floor turn on and the HC08V/RF on the nd floor goes to stand-by brightness. The person walks to the nd floor, the nd HC08V/RF switches on. All HC0RF on the nd floor turn on and the HC08V/RF on the rd floor goes to stand-by brightness. HC0RF () HC08V/RF HC0RF () HC08V/RF The person walks to the rd floor, the rd HC08V/RF switches on. All HC0RF on the rd floor turn on and the HC08V/RF on the th floor goes to stand-by brightness. Meanwhile, the sensors on the st floor dim to stand-by brightness or go off after hold time. The person walks to the th floor, the th HC08V/RF switches on. All HC0RF on the th floor turn on and the next HC08V/RF goes to stand-by brightness... Meanwhile, the HC08V/RF on the st floor goes off after stand-by period, and the sensors on the nd floor dim to stand-by brightness after hold time. 8H manual on mode for LED lamp With simple operation, rapidly turn off/on the fixture cycles within sec. (the green LED on the sensor flashes and the fixture blinks times to indicate the success of setup), lamp will be on for 8 hours, and then automatically goes to sensor mode after 8 hours. Useful when sensor function is not needed in special occasion. This 8H manual on feature can be cancelled by turn off/on the fixture cycle within sec. Ambient daylight threshold With simple operation, rapidly turn off/on the fixture cycles within sec:. The green LED on the sensor flashes slowly for 5 seconds, meanwhile the fixture blinks twice.. The daylight sensor measures and remembers the surrounding lux for sec.. The fixture and green LED is on for 0s to indicate the success of learning. * This feature enables the fixture to function well in any real application circumstance, where the daylight penetrated into fixture may vary a lot. * The latest surrounding lux value overwrites previous lux value learned. * Both the settings on DIP switch and the learned ambient lux threshold can overwrite each other.the latest action stays in validity. Hytronik Microwave motion sensor 5

4 0 Zero-cross relay operation Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing through the relay contact point, and enable the maxi. load and life-time of the relay. 5 Loop-in and loop-out Double L N terminal makes it easy for wire loop-in and loop out, saves the cost of terminal block and assembly time. RF Manual Grouping override (max. ( for HC08V/RF channels) only ) This sensor reserves the access of manual override function for end-users to switch on/off, or adjust the stand-by dimming level with the push-switch, which makes the product more user-friendly, and more options to fit for some extra-ordinary demands. * Short push (<s): on/off; ON OFF: the light turns off immediately and can not be lighten for a certain time (equals to hold time preset) even movement is detected. After this period, the sensor goes to auto sensor mode. OFF ON: the light turns on and goes to sensor mode, even when ambient LUX level exceeds the daylight threshold. * Long push (>s): dim up/down the stand-by dimming level between and. Both the settings on DIP switch and manual override can overwrite each other, the latest action stays in validity. *If customers do not want to have this manual override function, we can just leave this push terminal alone, not connected to any wire. Note:. Motion sensor overwrites daylight sensor, meanning the daylight sensor starts to check the ambient natural light only when the lamp is switched off (motion hold-time elapsed).. -0V output on the unit HC08V /RF is isolated, SELV output. Wiring Diagram ))))))))))))))))) RF Signal Detection Pattern 0 9 ceiling mounting height(m) 0% 75% wall mounting height 0% 75% ceiling mounting pattern (m) wall mounting pattern (m) 5 Hytronik Microwave motion sensor

5 Settings (HC08V/RF) can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. I maximum range up to II 75% III IV means the time period you would like to keep the lamp on after the person has left the detection area. 5s 0s I 5s II 0s III minute IV 5 minutes V 0 minutes VI 0 minutes VII 0 minutes Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. Note: 0s means on/off control; + means steps dimming control, fixture never switches off. 8 0s 0s min 5min 0min 0min H + I 0s II 0s III minute IV 5 minutes V 0 minutes VI 0 minutes VII H VIII + Stand-by dimming level This is the dimmed low light output level you would like to have after the hold-time in the absence of people. Note: the stand-by period and stand-by dimming level set up on the is only valid for the unit (HC08V/RF). 0% 0% I II 0% III 0% IV 5 The daylight threshold can be set on DIP switches, to fit for particular application. Disable 50Lux 0Lux Lux I Disable II 50Lux III 0Lux IV Lux Technical Data Operating voltage Switched power Coding Hold time Stand-by period Daylight threshold RF. Communicatin Chanels Microwave frequency Microwave power Detection range Detection angle RF. Transmission distance Mounting height Operating temperature RF frequency Certificate 0-0VAC 00W Fixed address coding (rotary coding switch for grouping) 0/50/75/, can be customized 5s/0s/min/5min/0min/0min/0min, can be customized 0s/0s/min/5min/0min/0min/hour / + ~50 lux, disable, can be customized channels for grouping 5.8GHz+/-75MHz <0.mW Max. (DxH ): m x m 0~50 O 0 meters indoor, 00 meters in open area Max. m. -5 o C ~ +70 o C /88 /5 / 95 MHz (FSK mode) Semko, EMC, CE, R&TTE, SAA Hytronik Microwave motion sensor 5

FSTR Series Sensor with RF Wireless Transmission Control Model: HC428V/RF, HC418V/RF, & HC424RF

FSTR Series Sensor with RF Wireless Transmission Control Model: HC428V/RF, HC418V/RF, & HC424RF FSTR Series Sensor with RF Wireless Transmission Control Model: HC428V/RF, HC418V/RF, & HC424RF This is a combination of motion sensor and RF radio wave wireless transmission, which is perfect solution

More information

Fixture Built-in Sensor Daylight Harvest Version

Fixture Built-in Sensor Daylight Harvest Version Fixture Built-in Sensor Daylight Harvest Version Model: HC419VRC /DH Infrared remote receiver Detection area Hold-time Daylight sensor Buzzer Sensor antenna Photocell Installation hole (4.2mm) 4.2 45 Stand-by

More information

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only. Synchrony ighting Control With Wireless Technology HBT01 / HBT02 with HC038V / HCD038 Built-in Detachable Version Applications The freedom of wireless mesh networks configured by smartphone APP s considerably

More information

Product Specification

Product Specification Product Specification Project: Microwave motion sensor Version:5.0 Date: 24/12.2008 Model : HC001S Pages:15 1 Objective The objective of this microwave motion sensor is to provide automatic intelligent

More information

Human Centric Lighting System

Human Centric Lighting System Human Centric Lighting System PIR HHC24 HHC23 HHC245 Circadian Rhythm sensor with Tunable white LED driver Lighting can reduce energy bills, it also can boost productivity and promote the wellbeing of

More information

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

Philips Ledalite Phone: Fax: Web:   Programming Guide Version 2.0 Philips Ledalite Phone: 604.888.6811 Fax: 800.665.5223 Web: www.ledalite.com Programming Guide Version 2.0 AIRWAVE PROGRAMMING GUIDE 1.0 Linking/Unlinking an Airwave Switch or Photosensor to a Transceiver

More information

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup. Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2

More information

Installation hole (4.2mm) Push. Ambient daylight threshold. 8 hours manual on

Installation hole (4.2mm) Push. Ambient daylight threshold. 8 hours manual on STPSENSOR fr STRIP Mdel: STPSENSOR Infrared remte receiver Remte Cntrl (SENSORRC) sld separately Sensr antenna Buzzer Detectin area LED indicatin. Daylight threshld Stand-by perid 6. 9. 0 SYNC SYNC N L

More information

Product Specifications

Product Specifications VLC Product Specifications Luce LED High Bay W Luce LED High Bay EO-LC- EO-LC-T EO-LC-HV EO-LC-HVT Ultra Thin Round Disc Design System Light Efficacy LPW Easy Installation & Maintenance IP7 Five Years

More information

Technical Application Guide

Technical Application Guide Lighting Control Wireless Occupancy Sensor, Wireless Multi Sensor Technical Application Guide Easily enhance your smart lighting system with the Philips wireless occupancy sensor and multi sensor, which

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE FSP-2X1 Digital High/Low Pir Fixture Integrated Sensor INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

More information

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003 MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com General Description Indoor universal mechanism box mounted KNX motion

More information

with Light Level, Isolated Relay and Manual On features

with Light Level, Isolated Relay and Manual On features DT-200 version 3 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features SPECIFICATIONS Voltage... 18-28VDC/VAC Current Consumption... 25mA Power Supply...WattStopper

More information

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features Product Guide EBDSPIR-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling

More information

PRODUCT DATASHEET Alphard Bulkhead Microwave Sensor

PRODUCT DATASHEET Alphard Bulkhead Microwave Sensor Alphard Bulkhead Sensor PRODUCT DATA Range Part Code(s) Applicatis Warranty Certificati(s) Bulkheads R8/MW nterior/ Exterior 5 years CE, RoHS PHYSCAL DATA Colour Finish Dimensis (mm) Luminaire Fixing Cstructi

More information

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number Radio motion detector comfort 1.1 m/2.2 m quicklink Order number 8534 51.. Operating instructions 1. Safety instructions Electrical equipment may only be installed and assembled by a qualified electrician

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,

More information

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR CAUTIONS INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including

More information

This document is intended for Lighting Control Systems professionals

This document is intended for Lighting Control Systems professionals This document is intended for Lighting Control Systems professionals This document applies to fixture with factory installed SVPD1, SVPD2, SVPD3 integrated sensors. Table of contents Quick Reference Guide...

More information

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE This elegant low-profile LED canopy fixture is ideal for parking garages or other applications using MetalHalide (MH), High-Pressure Sodium (HPS) or High Intensity Discharge (HID) luminaires. This fixture

More information

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4 DESCRIPTION AND OPERATION The is a motion sensor that dims lighting from high to low based on movement. This slim, low-profile sensor is designed for installation inside the bottom of a light fixture body.

More information

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features Product Guide EBDHS-MB-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-MB-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling

More information

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012 Understanding the capabilities of Digital Lighting Management (DLM) photosensors, and how to configure the sensors for the desired control strategy is one key to successful daylighting controls projects.

More information

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow Sense Command Control Third Eye Energy Saving Sensors Save Energy Today for a Better Tomorrow Save Energy Today for a Better Tomorrow Motion Sensor History The first motion detector burglar alarm was invented

More information

High/Low Bay Passive Infrared Occupancy Sensor

High/Low Bay Passive Infrared Occupancy Sensor Models Sensors: HBP-111-L7, with IR remote capability HBP-112-L7, no IR capability High/Low Bay Passive Infrared Occupancy Sensor Mounting Modules: HBP-EM1 extender module HBP-SM1 surface mount module

More information

EBDSM-PRM Product Guide

EBDSM-PRM Product Guide EBDSM-PRM Product Guide Ceiling PIR presence/absence detector Overview The EBDSM-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual control.

More information

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features Product Guide EBDHS-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling

More information

RF ceiling microwave presence detector DALI / DSI

RF ceiling microwave presence detector DALI / DSI MWS3A-AT-DD Product Guide RF ceiling microwave presence detector DALI / DSI Overview The MWS3A-AT-DD is a passive microwave motion sensor combined with two output channels capable of controlling incandescent,

More information

Dialight Daylight Harvesting Sensor User Guide

Dialight Daylight Harvesting Sensor User Guide Daylight Harvesting Sensor Dialight Daylight Harvesting Sensor User Guide Dialight Catalog Number: DLHU124UG2 1 Safety Instructions Dialight Daylight Harvester Sensor (DLH) User Guide READ AND FOLLOW ALL

More information

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES: PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 5 PIR OCCUPANCY SENSOR DESCRIPTION & OPERATION: These fixture mounted sensors provide multi-level control based on motion and/or daylight

More information

Motion Sensors. Product Features. Applications

Motion Sensors. Product Features. Applications Motion Sensors Many areas like lobbies, parking garages, staircases remain unused for long hours, but do need lighting to be lit automatically in case of movement. A motion sensor is a device, which detects

More information

Operating instructions II / 2004

Operating instructions II / 2004 Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)

More information

User Manual 3X300 DIMMER MODULE DM03B02KNX

User Manual 3X300 DIMMER MODULE DM03B02KNX User Manual 3X300 DIMMER MODULE DM03B02KNX 1/29 Index 1.... Presentation of the Dimming functions 3 2.... Configuration and param. of the Dimming functions 5 3.... Physical addressing 29 2/29 1. Presentation

More information

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter

More information

KNX ENO 620/622 (32-channel AP)

KNX ENO 620/622 (32-channel AP) KNX O 620/622 (32-channel AP) Gateway between EnOcean and the KNX bus Operating and installation manual Installation and connection Fig. 1: KNX O 620 Fig. 2: KNX O 622 Application KNX O 620 and 622 serve

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL PREFACE This installation & operation manual is intended as an instruction manual for trained person who is in charge of installation, maintenance, repair, etc. Before installation

More information

focushand 2 Users Manual FocusHAND System description

focushand 2 Users Manual FocusHAND System description FocusHAND System description focushand 2 Users Manual FocusHAND is a wireless remote control unit with a DMX output, to be used for controlling lighting fixtures while focussing them. This means that the

More information

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI 2013.09 Control Guide Content: 1 2 3 4 5 6 7 8 9 10 11 Ensure right physical install of all hardware / use remote control to commission

More information

Motion Sensors. Product Features. Applications

Motion Sensors. Product Features. Applications Motion Sensors Many areas like lobbies, parking garages, staircases remain unused for long hours, but do need lighting to be lit automatically in case of movement. A motion sensor is a device, which detects

More information

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , , 0.0.1 Move/monitoring 1305/1.0, Art. No. 6316.., 6326.., 6318.. General Application 1305/1.0 has been developed for the KNX movement detector, Merten article numbers 6316.., 6326.. and 6318... In the following

More information

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER This elegant low-profile LED canopy fixture is ideal for parking garages or other applications using Metal Halide (MH), High-Pressure sodium (HPS) or High Intensity Discharge (HID) luminaires. This fixture

More information

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR Product Overview The is a fixture-integrated dimming photosensor. It provides a continuous dimming signal to a 0-10 VDC dimming ballast, based on daylight

More information

KNX manual 1-channel flush-mounted switch actuator SU 1

KNX manual 1-channel flush-mounted switch actuator SU 1 KNX manual 1-channel flush-mounted switch actuator SU 1 4942520 2018-10-04 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The SU 1 application programme 7 4.1 Selection in the product

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

v3 360 Passive Infrared Line Voltage Occupancy Sensor

v3 360 Passive Infrared Line Voltage Occupancy Sensor SPECIFICATIONS CI-355 v3 360 Passive Infrared Line Voltage Occupancy Sensor with Light Level feature Voltages... 120//230/277/347VAC, 50/60Hz Load Ratings @120VAC...0-800W Ballast/Tungsten/LED @230VAC

More information

Wireless Copilot. Safe2Fly - Height Only Version. Page NanoQuip Ltd

Wireless Copilot. Safe2Fly - Height Only Version. Page NanoQuip Ltd Wireless Copilot Safe2Fly - Height Only Version Page Contents Warnings... 3 Features... 4 Specifications... 5 Installation... 6-8 Receiver Battery... 6 Transmitter Installation... 7-8 How to Use This Manual...

More information

Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor LOS-WDT 1 11.04.08 Dual Technology Wall Mount Occupancy Sensor Models Available The wall-mount dual-technology sensors are used to control lighting in spaces that have pendant fixtures, ceiling fans, or

More information

Wireless Ceiling Mount Sensor

Wireless Ceiling Mount Sensor Wireless Ceiling Mount Sensor Lutron s occupancy and vacancy sensors are wireless ceiling-mounted battery-powered passive infrared (PIR) sensors that automatically control lights via RF communication to

More information

ActiLume 1-10V. OEM application guide

ActiLume 1-10V. OEM application guide ActiLume 1-10V OEM application guide Contents Contents 1 What is the ActiLume 1-10V System 3 2 System characteristics 4 2.1 ActiLume 1-10V Sensor LRI 1655/00 4 2.2 Movement detector 5 2.3 Light sensor

More information

Installing the FSP-211 Sensor in Light Fixture

Installing the FSP-211 Sensor in Light Fixture (grey) WATTSTOPPER VOLTAGE HIGH/LOW/OFF PIR FIXTURE INTEGRATED OUTDOOR PHOTO/MOTION SENSOR Product Overview The is a passive infrared (PIR) outdoor sensor that raises or lowers the electric lighting level

More information

OCCUPANCY SENSOR REMOTE USER GUIDE

OCCUPANCY SENSOR REMOTE USER GUIDE OCCUPANCY SENSOR REMOTE USER GUIDE Use the handheld programming remote to test and adjust the settings of your occupancy sensor, which can accommodate up to six sensor parameter profiles. FSP-2X1 is the

More information

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control ZoneLite control unit The new Flex Connectors ZoneLite is an intelligently configurable all in one lighting control solution for many commercial lighting applications. Control can vary from ON/OFF/DIM,

More information

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C. TABLE OF CONTENT A. Installation and Mounting.. 3 1. Installation 3 2. Mounting.. 4 3. Receiver Addressing... 5 B. Key Interface. 7 C. LCD Interface...8 D. Start/Reset...9 E. Operation Mode.10 F. Time

More information

Technical Application Guide for UP-SHINE LED Linear

Technical Application Guide for UP-SHINE LED Linear Technical Application Guide for UP-SHINE LED Linear UP-DB9-6-12W-S UP-DB9-6-12W-E Introduction DB9 LED Linear is mainly designed for Oceania and European market, 2835 high lumen SMD LED chip been used

More information

Technical Guide for Radio-Controlled Advanced Wireless Lighting

Technical Guide for Radio-Controlled Advanced Wireless Lighting Technical Guide for Radio-Controlled Advanced Wireless Lighting En Table of Contents An Introduction to Radio AWL 1 When to Use Radio AWL... 2 Benefits of Radio AWL 5 Compact Equipment... 5 Flexible Lighting...

More information

OCC Motion Sensor. Guide: how to program and use

OCC Motion Sensor. Guide: how to program and use OCC Motion Sensor Guide: how to program and use Sensor Selector Guide Contact us for a copy of our sensor selector guide to provide you with more in depth information on our various options. Which sensors

More information

Technical Application Guide for UP SHINE LED T8 Batten UP-AL06-9W-BO-M

Technical Application Guide for UP SHINE LED T8 Batten UP-AL06-9W-BO-M Technical Application Guide for UP SHINE LED T8 Batten UP-AL6-9W-BO-M Introduction T8 diffused batten suitable for ceiling, wall or pendant mounting. Prismatic diffuser for visual comfort. Cover plate

More information

ST500 Indoor LED Activator Starterkit Preliminary Datasheet. Features. Applications. Description. Electrical Connection

ST500 Indoor LED Activator Starterkit Preliminary Datasheet. Features. Applications. Description. Electrical Connection Features Movement Detector for Indoor LED Lighting Compatible with most RFbeam K-LCx Sensors 1...10V Analog and Isolated Digital Output Adjustable Sensitivity and Hold Time Adjustable Ramp Times and Brightness

More information

Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor Occupant -1 02.01.06 Dual Technology Wall Mount Occupancy Sensor Models Available The Series wall-mount dual-technology sensors are used in spaces with pendant fixtures, ceiling fans, or high ceilings

More information

EIB/KNX Switch Actuators. User manual

EIB/KNX Switch Actuators. User manual EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------

More information

3000W multi Pir light controller

3000W multi Pir light controller 3000W multi Pir light controller Cat No. MLB3000 - Black Cat No. MLW3000 - White Installation & Operating Instructions INSTALLATION & operating instructions SECTION ONE GENERAL INFORMATION The unit utilises

More information

STX Stair lighting controller.

STX Stair lighting controller. Stair lighting controller STX-1792 STX-1792 controller is used to control stairs lighting dynamically. The backlight is switched on with the subsequent steps, depending on the motion directions: ascending

More information

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System 1/8 Product description The Philips ActiLume lighting control system consists of a small, lightweight sensor and controller, designed for easy integration into luminaires. ActiLume is a true Plug and Play

More information

www.greenelectricalsupply.com Installation Guide Model: WLVD Wireless Low Voltage Dimmer (Receiver) Specifications: Power Supply 24 V DC Place on 24V power line prior to light load. 10A Maximum Load Package

More information

MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM

MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM This elegant low-profile LED canopy fixture is ideal for parking garages or other applications using Metal Halide (MH), High-Pressure Sodium (HPS) or High Intensity Discharge (HID) luminaires. This fixture

More information

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires Instruction Bulletin 63249-500-08A6 05/2011 High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires SLSPIP210EB and SLSPIP210EBCT INTRODUCTION Figure 1: High Bay Occupancy Sensor for Use

More information

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE MOS-21 Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE This guide covers all models of MOS-21 Ceiling occupancy sensor. The MOS-21 product

More information

Short operating instructions

Short operating instructions gottardo LED office floor lamp series I Short operating instructions Visit us online too. gottardo-led.swiss Product film on Youtube Operating instructions gottardo series I Version: 1.0/20180406/SN SW:20170224

More information

EasyAir Office sensor advanced grouping SNS200

EasyAir Office sensor advanced grouping SNS200 Sensors EasyAir office sensor advanced grouping SNS200 Datasheet EasyAir Office sensor advanced grouping SNS200 The Philips EasyAir office sensor is the ideal solution for per-luminaire control of new

More information

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system 1/7 Product description The Philips ActiLume Wireless 1-10V lighting control system consists of a small, lightweight sensor and a switchbox (controller), designed for easy integration into luminaires.

More information

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING Product Overview The FSP-2x1B is a family of passive infrared (PIR) outdoor sensors that raise or lower the electric

More information

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26 309 484 01 RAMSES 784 HF Set 1 784 9 407 784 9 417 Bedienungsanleitung Uhrenthermostat 1 Operating Instructions Clockthermostat 14 Mode d emploi Thermostat à horloge 26 Gebruiksaanwijzing Klokthermostaat

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300

LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300 LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300 lighting 402-0036-160914 Multi-functional Controller for Spectravision Pool Lights and 2 auxiliary circuits Table of contents Technical

More information

Experiencing trouble with your zboost setup? Installation Tips. Please note the following important factors in determining zboost performance:

Experiencing trouble with your zboost setup? Installation Tips. Please note the following important factors in determining zboost performance: Experiencing trouble with your zboost setup? Please note the following important factors in determining zboost performance: 1. Vertical Separation: At least 15 vertical feet is needed between the External

More information

Wireless Network Manager (NM) and Wireless Transceiver (TRV)

Wireless Network Manager (NM) and Wireless Transceiver (TRV) R Installation and Operation Instructions Wireless Network Manager (NM) and Wireless Transceiver (TRV) for PLATINUM CONTROLS With COMMUNICATION The New Heat-Timer Wireless Network Sensor System is designed

More information

Unidirectional Gateway EnOcean - KNX/BUS

Unidirectional Gateway EnOcean - KNX/BUS Unidirectional Gateway EnOcean - KNX/BUS Page 1.Use...1 2. Technical features...................1 3.Overalldimensions...1 4.Connection...2 5. Operation...2 6. Standards and approvals............3 7.Maintenance...3

More information

Light Management Systems for Indoor Use MULTISENSORS

Light Management Systems for Indoor Use MULTISENSORS Light Management Systems for Indoor Use MULTISENSORS MULTISENSORS Daylight and motion sensors both enable greater energy savings to be made and increase the convenience factor. For this reason, we have

More information

Astra-R Kit Wireless Alarm System Operation Manual

Astra-R Kit Wireless Alarm System Operation Manual Astra-R Kit Wireless Alarm System Operation Manual This operation manual describes principles of functioning, proper use, maintenance and service for the wireless alarm system Astra- R Kit (Figure 1).

More information

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to

More information

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat quicklink KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat solar quicklink Order no.:

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR FSP-22 FSP-212 * Models FSP-22, 12-32VDC Use with dim-to-off driver or ballast or with Wattstopper power pack FSP-212,

More information

Product and Applications Description

Product and Applications Description Product and pplications Description Diagram The transmitter 230V wave UP 110 (Diagram ) is a flushmounted device with radio communication for the wireless operation of room functions. It is possible to

More information

www.greenelectricalsupply.com Radio Powr SavrT Wireless Occupancy / Vacancy Ceiling Sensor LutronR Radio Powr SavrT occupancy/vacancy sensors are wireless, battery-powered passive infrared (PIR) sensors

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL FOR RBDA-PCS-1/25W-90-A INDOOR REPEATER TABLE OF CONTENTS PARAGRAPH PAGE NO BDA OVERVIEW 3 BDA BLOCK DIAGRAM DESCRIPTION 3 FCC INFORMATION FOR USER 3 BDA BLOCK DIAGRAM

More information

SeeTool - Solutions for KNX

SeeTool - Solutions for KNX SeeTool - Solutions for KNX Office building segment Application 8.2.1.0.0.4 Movement dependent automatic light control with light regulation and manual control, temperature control (electrical heating

More information

EasyAir office sensor standalone SNS100

EasyAir office sensor standalone SNS100 Sensors EasyAir office sensor standalone SNS100 Datasheet EasyAir office sensor standalone SNS100 The Philips EasyAir office sensor is the ideal solution for per-luminaire, stand-alone control of new light

More information

3000W MULTI PIR LIGHT CONTROLLER

3000W MULTI PIR LIGHT CONTROLLER 3000W MULTI PIR LIGHT CONTROLLER Cat No. MLB3000 Black Cat No. MLW3000 White Installation & Operating Instructions INSTALLATION & OPERATING INSTRUCTIONS E G Dusk/Dawn Time Override/Holiday Mode F H Lens

More information

QAM Snare Isolator User Manual

QAM Snare Isolator User Manual QAM Snare Isolator User Manual QS-ISO-1.6 9/1/15 This document details the functions and operation of the QAM Snare Isolator leakage detector Table of Contents Overview... 3 Screen Navigation... 4 Settings...

More information

Wireless 900 MHz Receiver

Wireless 900 MHz Receiver Overview and Identification The 900 MHz unit receives a repeated or re-transmitted RF signal from one or more wireless temperature or humidity transmitters. The signal from the transmitter (418 MHz) is

More information

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG 2 490 0 220 DME 2 490 0 221 DMB 2 490 0 222 Date: Aug-07 (subject to alterations) Page 1 of 36 Contents 1 FUNCTIONAL CHARACTERISTICS...

More information

Wireless Control Systems

Wireless Control Systems Wireless Control Systems Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Receivers Accessories Programming Switching & Dimmer Functions

More information

WIRELESS DIMMER FOR HEATING

WIRELESS DIMMER FOR HEATING TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation

More information

EasyAir Office sensor advanced grouping SNS200

EasyAir Office sensor advanced grouping SNS200 Sensors EasyAir office sensor advanced grouping SNS200 Datasheet EasyAir Office sensor advanced grouping SNS200 The Philips EasyAir office sensor is the ideal solution for per-luminaire control of new

More information

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE MOS-IR/DT Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE This guide covers all models of MOS-IR and MOS-DT ceiling occupancy sensor. The MOS-IR product family includes:

More information

SAPLING WIRELESS SYSTEM

SAPLING WIRELESS SYSTEM SAPLING WIRELESS SYSTEM Sapling Wireless System DESCRIPTION A Wireless Clock System starts with a master clock with a transmitter. The master clock s transmitter transmits the time data to the secondary

More information

USB RX Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

USB RX Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso USB RX Speed 19348 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S U S B R X S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7 3 3 2 4 English 1-8

More information

Radio Link Starter Kit

Radio Link Starter Kit Radio Link Starter Kit Installation Manual BARTLETT Instrument Co. 1032 Avenue H Fort Madison, IA 52627 319-372-8366 www.bartinst.com Table of Contents Radio Link Starter Kit Manual... 3 System Requirements...

More information

PWM LED strip dimmer module for the Velbus system

PWM LED strip dimmer module for the Velbus system VMB1LED PWM LED strip dimmer module for the Velbus system CONTENTS CONTENTS... 2 DESCRIPTION... 3 CHARACTERISTICS... 3 VELBUS CHARACTERISTICS... 5 OVERVIEW... 6 LED INDICATION... 7 USE WITHOUT VELBUS...

More information