CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

Size: px
Start display at page:

Download "CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003"

Transcription

1 CFO900 Series User Manual Audio/Data/Current Loop Mux/Demux CSX, CSX23 & CSX222 CFO CSX series user manual, , rev003

2 Contents The CSX Series Multiplexer Introduction... Introduction... Frame installation...2 Stand-alone installation...2 Audio Multiplexer / Demultiplexer CSX (version D)...3 General...3 Settings before installation...3 Master / Slave...3 Connection to a fi bre link...3 Application example...3 Audio connections...4 Led indicators and alarms...5 Audio, Data and Current Loop Multiplexer / Demultiplexer CSX23 (version D)...6 General...6 Settings before installation...6 Master / Slave...6 Single Channel Mode / Multi Channel Mode...6 Connection to a fi bre link...6 Application example...7 Audio connections...7 Data connections...8 Current Loop (C Loop) / Contact Closure (CC) connections...2 Led indicators and alarms...3 Data Multiplexer / Demultiplexer CSX222 (version F)...4 General...4 Settings before installation...4 Master / Slave...4 Single Channel Mode / Multi Channel Mode...4 Connection to a fi bre link...4 Application example...5 Data connections...5 Led indicators and alarms...9 Technical Specifications...20 Copyright acknowledgements...2 CFO CSX series user manual, rev003

3 The CSX Series Multiplexer Introduction Bi-directional digital audio, data, contact closure multiplexers / demultiplexers CSX, 23 & 222. CSX CSX23 CSX222 Introduction The CSX, 23 and 222 units are bi-directional multiplexers / demultiplexers, which can transmit audio, data and current loop channels (depending the CSX unit in question) within a single CFO series video channel. A separate video channel is required for each transmission direction. Depending on the chosen CFO video modem, high quality audio and/or data signals can be achieved for typical distances of 3 to 4 kilometres on multimode optical fi bre and up to several tens of kilometres on singlemode fi bre. CSX units are compatible with all CFO rack systems. Stand-alone options are available with the CMA02 module adapter and separared CPS series mains adapter. CSX Audio mux/demux 2 x Audi any CFO video channel optical fibre any CFO video channel CSX Audio mux/demux CSX23 Audio/Data/CLoop mux/demux 2 x C Loop 2 x C Loop any CFO video channel optical fibre any CFO video channel CSX23 Audio/Data/CLoop mux/demux 2 x C Loop 2 x C Loop CSX222 Data mux/demux any CFO video channel optical fibre any CFO video channel CSX222 Data mux/demux CFO CSX series user manual, rev003

4 Frame Installation rear view The CSX unit is to be pushed along the guide rails into the installation frame (e.g. CSR26 or 36 series) and secured with the four locking screws. The unit can be freely positioned in any slot in the frame (0HP). The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 or CPS390 power supply unit (the installation frame s own power supply.) CONTROL BUS CONTROL/ ALARM Stand-alone Installation The CSX unit can be installed for stand-alone use by using a CMA02 or CMA03 module adapter (see picture ). The module should be mounted to a vertical surface. The 2V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output,(e.g. CPS23). Please refer to separate documention for module adapters and mains adapters. 6 POWER V GND Picture. CMA02 module adapter ) Grounding connector 2) Supply voltage connector Picture 2. CPS23 power supply with connector. 2 CFO CSX series user manual, rev003

5 CSX (version D) 2 3 LE LK STATUS UNIT ALARM front view AUDIO MULTIPLEXER General The CSX is a bi-directional audio multiplexer / demultiplexer, which can transmit 6 audio channels in a single CFO series video channel. A separate video channel is required for each transmission direction. Settings before installation 4 AUDIO AUDIO 3 AUDIO 2 AUDIO 4 The unit has some settings that must be defi ned by internal DIP switches before installation. See picture 5 for CSX s switch locations. Master / Slave AUDIO 5 AUDIO 6 Each bi-directional link must have a master unit and a slave unit. Master / Slave confi guration errors are shown by LED displays (see page 5 and table 6). Note! Although the unit can be taken in use with default factory settings, the MASTER / SLAVE setting in bi-directional systems must always be determined to guarantee basic link operation. 5 Picture 3. CSX Audio Mux/Demux ) Locking screws. 2) Line input and output connectors (BNC female). 3) Link status and unit alarms. 4) Audio ch...ch6 input and output connections (HD5 female). 5) Handle. See further information on dedicated sections. Switch On Master Off Slave Table. The underlined function is default factory setting (see picture 5). Connection to a fibre link In typical installation the 6.6 Mb/s multiplexed data signal is connected from CSX s LE connector to any available CFO link s VIDEO PUT connector. On the other end of link, data signal is again connected from CFO link s VIDEO PUT connector to LE connector in corresponding CSX unit. If bi-directional service is required, a similar connection is needed by means of a separate return video channel. Application example 3 x Video CFO fibre CFO 3 x Video Tx Rx 6 x Audio CFO CSX CFO CSX 6 x Audio CFO CSX series user manual, rev003 3

6 5 6 5 Picture 4. HD5 female connector s pin order. Pin Signal Audio 2 input - 2 Audio 2 input + / unbalanced input 3 Ground 4 Audio out - 5 Audio out + / unbalanced output 6-0 Ground Audio input - 2 Audio input + / unbalanced input 3 Ground 4 Audio 2 out - 5 Audio 2 out + / unbalanced output Table 2. HD5 female connector s pinouts for AUDIO channels. Audio connections The nominal input and output level is 0 dbm. The connector in use is a HD5 female connector (see picture 4). The audio inputs can be switched to either balanced or unbalanced, and the input impedance (between input +/-) to 600 Ω or high impedance. The audio outputs can be also switched to either balanced or unbalanced. The output impedance can be switched to 600 Ω or low impedance. Led Colour Status Audio inputs Green Level > 0 dbm Yellow (blinking) Overload > 2 dbm Audio outputs Green Level > 0 dbm Yellow (blinking) Overload > 2 dbm Table 3. AUDIO connection s indicator operation. DIP switches -> Config. mode Audio Audio 2 Audio Balanced input off off Unbalanced input on on Input 600 Ω on on Input high Z off off Output 600 Ω off off off off Output low Z on on on on Table 4. DIP switch settings for AUDIO confi guration mode. The underlined functions are default factory settings. See picture 5 for location of CSX s DIP switches. DIP switch Setting Description on Audio input (-) to ground 2 on 600 Ω termination is selected in audio input 3 on 600 Ω termination is selected in audio 2 input 4 on Audio 2 input (-) to ground 5 on Audio 2 (-) output low impedance off Audio 2 (-) output 600 Ω 6 on Audio 2 (+) output low impedance off Audio 2 (+) output 600 Ω 7 on Audio (-) output low impedance off Audio (-) output 600 Ω 8 on Audio (+) output low impedance off Audio (+) output 600 Ω Table 5. Description of the DIP switches. + = Non-inverted or unbalanced input / output. - = Inverted input / output. 4 CFO CSX series user manual, rev003

7 Audio & 2 Audio 3 & 4 SW OFF 8 Audio 5 & 6 ON SW Master / slave, SCM / MCM 4 OFF ON Picture 5. DIP switch positions. Led indicators and alarms Link status Led Alarm active Status Trigger condition Green Link OK No error signals Green blinking B Few errors PacketSync or FrameSync data was imperfect Green / Yellow B (and audio muted) Bad confi g ur at i o n Both units are confi gurated to be Master (or be Slave) Yellow B2, B (and audio muted) Table 6. Link status indicator operation. Table 7. Unit alarm indicator operation. Serious errors Data framing errors (unit could not synchronise to bitstream). Unit alarm Led Alarm active Status Trigger condition Yellow blinking B3, B (and Bad input PLL can t lock to audio muted) signal input signal. All alarms at the back connector of the unit are low, open collector outputs with a capability of 30V / 0mA switching. CFO CSX series user manual, rev003 5

8 CSX23 (version D) 2 3 LE LK STATUS UNIT ALARM front view AUDIO DATA CL MULTIPLEXER General The CSX23 is a bi-directional audio, data and current loop multiplexer / demultiplexer, which can transmit 2 audio, 2 data and 2 current loop channels in a single CFO series video channel. A separate video channel is required for each transmission direction. Settings before installation 4 AUDIO DATA AUDIO 2 DATA 2 The unit has some settings that must be defi ned by internal DIP switches before installation. See page 0 and picture 0 for CSX23 s switch locations. Master / Slave C LOOP C LOOP 2 Each bi-directional link must have a master unit and a slave unit. Master / Slave confi guration errors are shown by LED displays (see page 3 and table 20). 5 Picture 6. The CSX23 ) Locking screws. 2) Line input and output connectors (BNC female). 3) Link status and unit alarms. 4) Data ch / ch2 input and output connections (HD5 female). 5) Handle. See further information on dedicated sections Note! Although the unit can be taken in use with default factory settings, the MASTER / SLAVE setting in bi-directional systems must always be determined to guarantee basic link operation. Switch On Master - SCM - Off Slave - SCM - Table 8. The underlined function is default factory setting (see picture 0). Single Channel Mode / Multi Channel Mode This switch refers to data slot of the unit. In MCM mode, all data channels are in use and the bit rate has a standard value. If a higher bit rate is required, a SCM mode is selected. In SCM mode only the fi rst data channel of data slot can be used. Connection to a fibre link In typical installation the 6.6 Mb/s multiplexed data signal is connected from CSX s LE connector to any available CFO link s VIDEO PUT connector. On the other end of link, data signal is again connected from CFO link s VIDEO PUT connector to LE connector in corresponding CSX unit. If bi-directional service is required, a similar connection is needed by means of a separate return video channel. 6 CFO CSX series user manual, rev003

9 Application example 2 x C loop 3 x Video CFO fibre CFO 3 x Video Tx Rx CFO CSX 23 CFO 6 Rx fibre CFO 6 Tx CFO CSX 23 2 x C loop Picture 7. HD5 female connector s pin order. Pin Signal Audio 2 input - 2 Audio 2 input + / unbalanced input 3 Ground 4 Audio out - 5 Audio out + / unbalanced output 6-0 Ground Audio input - 2 Audio input + / unbalanced input 3 Ground 4 Audio 2 out - 5 Audio 2 out + / unbalanced output Table 9. HD5 female connector s pinouts for AUDIO channels. Audio connections The nominal input and output level is 0 dbm. The connector in use is a HD5 female connector (see picture 7). The audio inputs can be switched to either balanced or unbalanced, and the input impedance (between input +/-) to 600 Ω or high impedance. The audio outputs can be also switched to either balanced or unbalanced. The output impedance can be switched to 600 Ω or low impedance. Led Colour Status Audio inputs & 2 Green Level > 0 dbm Yellow (blinking) Overload > 2 dbm Audio outputs & 2 Green Level > 0 dbm Table 0. AUDIO connection s indicator operation. DIP switches -> Config. mode Audio Audio 2 Audio Balanced input off off Unbalanced input on on Input 600 Ω on on Input high Z off off Output 600 Ω off off off off Output low Z on on on on Table. DIP switch settings for AUDIO confi guration mode. The underlined functions are default factory settings. See picture 5 for location of CSX23 s DIP switches. CFO CSX series user manual, rev003 7

10 Table 2. Description of the DIP switches. + = Non-inverted or unbalanced input / output. - = Inverted input / output. DIP switch Setting Description on Audio input (-) to ground 2 on 600 Ω termination is selected in audio input 3 on 600 Ω termination is selected in audio 2 input 4 on Audio 2 input (-) to ground 5 on Audio 2 (-) output low impedance off Audio 2 (-) output 600 Ω 6 on Audio 2 (+) output low impedance off Audio 2 (+) output 600 Ω 7 on Audio (-) output low impedance off Audio (-) output 600 Ω 8 on Audio (+) output low impedance off Audio (+) output 600 Ω 5 6 Data connections Two (RS422 / 485, TLL) or four (RS232) data channels for bidirectional transmission are available. The connector in use is a HD5 female connector (see picture 8). Led Colour Status 5 Picture 8. HD5 female connector pin order. Data inputs & 2 Green Data 0 Yellow Data or NC Data outputs & 2 Green Data 0 Yellow Data Table 3. DATA connection s indicator operation. Table 4. HD5 female connector pinouts * valid from version E) Pin Signal RS232 RS422 / 485 TTL Input 2 non-inverted input (+) 2 External resistor input A, (Data 2) 3 Ground 4 External resistor input B, (Data 2) 5 Output 3 inverted output (-) output 6 Input 4 inverted input (-) input 7 External resistor input A, (Data ) 8 Ground 9 External resistor input B, (Data ) 0 Ground Output 4 inverted output (-) output 2 Output 2 non-inverted output (+) 3 Input 3 inverted input (-) input 4 Output non-inverted output (+) 5 Input non-inverted input (+) 8 CFO CSX series user manual, rev003

11 DIP switch -> Data Confi guration mode SW SW2 RS232 off off off off off off off off on on on on TTL off on off off off on off off off on off on RS422 off off off on off on RS485 short time* off off on off on off RS485 long time** off off off off off off RS422 / 485 line bias on on on on RS422 / 485 no line bias off off off off RS422 / 485 term on on RS422 / 485 no term off off Table 5. DIP switch settings for DATA confi guration mode. The underline function is default factory setting. See picture 6 for location of DIP switches. * : 0.3 ms, :.2 ms ** :.2 ms, : 0 ms ( and time constant is adjustable by external resistor, more details are in separate application note available on request). 600 Ω 600 Ω + 5V 20 Ω + 5V 47 kω 47 kω Databuffer Picture 9. Line bias and fail safe implementation in RS422 / 485. SW DIP switch Description Line termination of channel, (20 Ω) 2 Voltage reference of TTL, (channel ) 3, 4 Line bias of RS422 / 485 input, (660 Ω, channel ) 5 Line termination of channel 2, (20 Ω) 6 Voltage reference of TTL, (channel 2) 7, 8 Line bias of RS422 / 485 input, (660 Ω, channel ) SW2, 2 Data mode selection, (channel ) 3, 4 Data mode selection, (channel 2) Table 6. Description of the DIP switches. CFO CSX series user manual, rev003 9

12 RS485 settings CH 2 CH full duplex operation half duplex operation CH 2 CH Audio & 2 Data & 2 CL & 2 SW SW2 OFF 8 4 OFF ON ON OFF 4 SW Master / slave, SCM / MCM ON SW2 Picture 0. CSX23 s DIP switch and jumper positions. Note! Jumper locations for RS485 4-wire full dublex operation are on the daughter board inside the unit. The jumper can be seen through the access hole in the outer casing. The default setting when operating in RS485 mode is half duplex. 0 CFO CSX series user manual, rev003

13 RS422 / wire RS485 2-wire RS232 TTL Ch3 Ch Vref Ch4 6 Vref Ch External resistor (RS485) 7 9 External resistor (RS485) 2 External resistor (RS485) 4 7 External resistor (RS485) , 7-0 3, 7-0 3, 8, 0 3, 8,0 Picture. Data interface connections. Tx is enabled when data is low Timing sequence, starts from low to high transition Time (ms) CSX23 data input.2 ms CSX23 Tx enable Tx enabled Tx disabled CSX23 data output Rx enabled TX high-z Rx enabled TX high-z Picture 2 Timing Diagram for half-duplex RS485 operation (more information on timing sequence adjustment can be found in a separate application note, which is available on request). CFO CSX series user manual, rev003

14 5 6 Current Loop (C LOOP) / Contact Closure (CC) Connections Two channels for current loops or voltage free contact closure lines are available. The 20 ma current loops can be switched to either active or passive mode. The connector in use is a HD5 female connector (see picture 3). 5 Picture 3. HD5 female connector pin order. Led Colour Status C Loop / CC inputs & 2 Green Current active / contact closed C Loop / CC outputs & 2 Green Current active / contact closed Table 7. CURRENT LOOP indicator operation Pin Signal Contact closure output A (24V DC / A) 2 C Loop 2 input + 3 C Loop input + 4 C Loop output - 5 Contact closure 2 output B (24V DC / A) 6 Contact closure output B (24V DC / A) 7-9 Ground 0 Contact closure 2 output A (24V DC / A) C Loop 2 output + 2 C Loop 2 output - 3 C Loop output + 4 C Loop input - 5 C Loop 2 input - Table 8. HD5 female connector pinouts for C Loop & CC inputs / outputs. DIP switches -> Config. mode Channel Channel 2 C Loop in active off on C Loop in passive on off C Loop out active on on C Loop out passive off off Relay output enable on on Relay output disable off off Table 9. CSX23 DIP switch settings for C Loop confi guration mode. The underlined functions are default factory settings. See picture 0 for location of CSX23 s DIP switches. When the currrent loop is active the current is generated in CSX23. In passive mode the terminal equipment generates the current (see the picture 4 for pin information). 2 CFO CSX series user manual, rev003

15 CL, passive 20 ma (= current generated by the data terminal equipment) CL, active 20 ma (= current generated by CSX23) CC Contact open = relay in CSX23 is open Contact closed = relay in CSX23 is closed Picture 4. Connection examles for C loop and contact closure operation. Led indicators and alarms Link status Led Alarm active Status Trigger condition Green Link OK No error signals Green blinking B Few errors PacketSync or FrameSync data was imperfect Green / Yellow B (and audio muted) Bad confi g ur at i o n Both units are confi gurated to be Master (or be Slave) Yellow B2, B (and audio muted) Table 20. Link status indicator operation. Table 2. Unit alarm indicator operation. Serious errors Data framing errors (unit could not synchronise to bitstream). Unit alarm Led Alarm active Status Trigger condition Yellow blinking B3, B (and Bad input PLL can t lock to audio muted) signal input signal. All alarms at the back connector of the unit are low, open collector outputs with a capability of 30V / 0mA switching. CFO CSX series user manual, rev003 3

16 CSX222 (version F) 2 3 LE LK STATUS UNIT ALARM front view DATA MULTIPLEXER General The CSX222 is a bi-directional data multiplexer / demultiplexer, which can transmit 6 data channels in a single CFO series video channel. A separate video channel is required for each transmission direction. Settings before installation DATA DATA 2 The unit has some settings that must be defi ned by internal DIP switches before installation. See picture 8 for CSX222 s switch locations. 4 DATA 3 DATA 4 Master / Slave DATA 5 DATA 6 Each bi-directional link must have a master unit and the slave unit. A Master / Slave confi guration error is shown with LED displays (see page 9 and table 27). Note! Although the unit can be taken in use with default factory settings, the MASTER / SLAVE setting in bi-directional systems must always be determined to guarantee the basic link operation. 5 Picture 5. The CSX222 ) Locking screws. 2) Line input and output connectors (BNC female). 3) Link status and unit alarms. 4) Data ch...ch6 input and output connections (HD5 female). 5) Handle. See further information on dedicated sections. Switch On Master - SCM - Off Slave - MCM - Table 22. The underlined function is default factory setting (see picture 8). Single Channel Mode / Multi Channel Mode These switches refers to equivalent slots of the unit, i.e. switch 2 refers to slot (data and 2), switch 3 to slot 2 (data 3 and 4) etc. In MCM mode, all data channels are in use and the bit rate has a standard value. If a higher bit rate is required, a SCM mode is selected. In SCM mode only the first data channel of each slot can be used. Connection to a fibre link In typical installation the 6.6 Mb/s multiplexed data signal is connected from CSX s LE connector to any available CFO link s VIDEO PUT connector. On the other end of link, data signal is again connected from CFO link s VIDEO PUT connector to LE connector in corresponding CSX unit. If bi-directional service is required, a similar connection is needed by means of a separate return video channel. 4 CFO CSX series user manual, rev003

17 Application example 3 x Video CFO fibre CFO 3 x Video Tx Rx CFO CFO 6 x Data CSX CSX 6 x Data CFO 6 Rx fibre CFO 6 Tx Picture 6. HD5 female connector pin order. Data connections Two (RS422 / 485, TLL) or four (RS232) data channels for bidirectional transmission are available in every slot. Data indicators, connections and switch settings are the same in all three slots of the unit. The connector in use is a HD5 female connector (see picture 6). Led Colour Status Data inputs & 2 Green Data 0 Yellow Data or NC Data outputs & 2 Green Data 0 Yellow Data Table 23. DATA connection s indicator operation. CFO CSX series user manual, rev003 5

18 Pin Signal RS232 RS422 / 485 TTL Input 2 non-inverted input (+) 2 External resistor input A, (Data 2, 4, 6) 3 Ground 4 External resistor input B, (Data 2, 4, 6) 5 Output 3 inverted output (-) output 6 Input 4 inverted input (-) input 7 External resistor input A, (Data, 3, 5) 8 Ground 9 External resistor input B, (Data, 3, 5) 0 Ground Output 4 inverted output (-) output 2 Output 2 non-inverted output (+) 3 Input 3 inverted input (-) input 4 Output non-inverted output (+) 5 Input non-inverted input (+) Table 24. HD5 female connector pinouts * valid from version E) DIP switch -> Data Confi guration mode SW SW2 RS232 off off off off off off off off on on on on TTL off on off off off on off off off on off on RS422 off off off on off on RS485 short time* off off on off on off RS485 long time** off off off off off off RS422 / 485 line bias on on on on RS422 / 485 no line bias off off off off RS422 / 485 term on on RS422 / 485 no term off off Table 25. DIP switch settings for DATA confi guration mode. The underline function is default factory setting. See picture 6 for location of DIP switches. * : 0.3 ms, :.2 ms ** :.2 ms, : 0 ms ( and time constant is adjustable by external resistor, more details are in separate application note available on request). 6 CFO CSX series user manual, rev003

19 600 Ω 600 Ω + 5V 20 Ω + 5V 47 kω 47 kω Databuffer Picture 7. Line bias and fail safe implementation in RS422 / 485. SW DIP switch Description Line termination of channel, (20 Ω) 2 Voltage reference of TTL, (channel ) 3, 4 Line bias of RS422 / 485 input, (660 Ω, channel ) 5 Line termination of channel 2, (20 Ω) 6 Voltage reference of TTL, (channel 2) 7, 8 Line bias of RS422 / 485 input, (660 Ω, channel ) SW2, 2 Data mode selection, (channel ) 3, 4 Data mode selection, (channel 2) Table 26. Description of the DIP switches. RS485 settings CH 2 CH full duplex operation half duplex operation CH 2 CH Audio & 2 Data & 2 CL & 2 SW SW2 OFF 8 4 OFF ON ON OFF 4 SW Master / slave, SCM / MCM ON SW2 Picture 8. CSX23 s DIP switch and jumper positions. Note! Jumper locations for RS485 4-wire full dublex operation are on the daughter board inside the unit. The jumper can be seen through the access hole in the outer casing. The default setting when operating in RS485 mode is half duplex. CFO CSX series user manual, rev003 7

20 RS422 / wire RS485 2-wire RS232 TTL Ch3 Ch Vref Ch4 6 Vref Ch External resistor (RS485) 7 9 External resistor (RS485) 2 External resistor (RS485) 4 7 External resistor (RS485) , 7-0 3, 7-0 3, 8, 0 3, 8,0 Picture 9. Data interface connections. Tx is enabled when data is low Timing sequence, starts from low to high transition Time (ms) CSX23 data input.2 ms CSX23 Tx enable Tx enabled Tx disabled CSX23 data output Rx enabled TX high-z Rx enabled TX high-z Picture 20. Timing Diagram for half-duplex RS485 operation (more information on timing sequence adjustment can be found in a separate application note, which is available on request). 8 CFO CSX series user manual, rev003

21 Led indicators and alarms Link status Led Alarm active Status Trigger condition Green Link OK No error signals Green blinking B Few errors PacketSync or FrameSync data was imperfect Green / Yellow B (and audio muted) Bad confi g ur at i o n Both units are confi gurated to be Master (or be Slave) Yellow B2, B (and audio muted) Table 27. Link status indicator operation. Table 28. Unit alarm indicator operation. Serious errors Data framing errors (unit could not synchronise to bitstream). Unit alarm Led Alarm active Status Trigger condition Yellow blinking B3, B (and Bad input PLL can t lock to audio muted) signal input signal. All alarms at the back connector of the unit are low, open collector outputs with a capability of 30V / 0mA switching. CFO CSX series user manual, rev003 9

22 Technical Specifications Parameter Specification Unit Note CSX CSX23 CSX222 Audio Number of channels pcs bi-directional Oversampling times Sample frequency khz Sampling resolution bits Input impedance 600/>0k 600/>0k - ohm selectable Output impedance 600/>0k 600/>0k - ohm selectable Nominal level dbm Clipping level dbm Frequency response khz db, ref. khz Distortion % khz + 9 dbm S/N dbqp CCIR weighted Data Number of channels - 3 pcs high rate, RS422/ pcs standard rate, RS422/485/TTL pcs standard rate, RS232 Bit rate kbps standard rate, RS232/422/485/TTL kbps high rate, RS422/485 Sample rate khz standard rate, RS232/422/485/TTL khz high rate, RS422/485 Jitter % maximum bit rate Configuration - RS232 RS232 selectable for each channel - RS422 RS422 - RS485 RS485 - TTL TTL Termination ohm RS422 and RS485, switchable to high-z (>0 kohm) Current Loop Number of channels pcs bi-directional Contact Closure Bit rate kbps current loop mode Jitter % max Configuration - active CL - selectable for both channels - passive CL - - contact closure - General Supply voltages VDC Current consumption 600 ma Dimensions (H x W x D) 3U 0HP 90 mm Weight 0.7 kg Operating temperature C Storage temperature C Mux/demux BNC female Audio/data/current loop HD5 female 20 CFO CSX series user manual, rev003

23 Copyright acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. Copyright Teleste Corporation. All Rights Reserved. No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation. Teleste Corporation Video Networks P.O. Box 323 F-200 Turku FLAND WEEE directive Directive 2002/96/EC of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE) obliges that producers appropriately mark electrical and electronic equipment with the symbol indicating separate collection. This obligation applies to the equipment put on the market in EU after 3 August Teleste devices which belong to the scope of the directive have been marked with the separate collection symbol shown below. The marking is according to the standard EN The symbol indicates that the device has to be collected and treated separately from unsorted municipal waste. User manual revision history note: The latest version is always available in pdf-format on our web site: CFO CSX series user manual, rev003 2

24

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form without

More information

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form

More information

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT Since 987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT CONTENTS General functionality and features of the equipment. Technical specifications. Application. Connection

More information

USER MANUAL SATEL i-link I/O-converter Version 1.6

USER MANUAL SATEL i-link I/O-converter Version 1.6 USER MANUAL SATEL i-link I/O-converter Version 1.6 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTICE... 3 PRODUCT CONFORMITY... 4 WARRANTY AND SAFETY INSTRUCTIONS... 5 1 GENERAL... 6 1.1 SATEL

More information

SNV-12 Voter Quick Reference Help Sheets

SNV-12 Voter Quick Reference Help Sheets Chassis, Power Supply, and CIM Module SNV-12 Configuration Settings and Adjustments (0=Off, 1=On) Chassis Rear Panel: Designator Factory Setting Switch Choices AC Line Voltage Rear Panel AC Input Module

More information

5000 Series Receiver Systems

5000 Series Receiver Systems 5000 Series Receiver Systems Modular multi-channel receiver system for demanding musical and broadcast applications Large mainframe houses up to 8 true diversity receiver modules Small mainframe houses

More information

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed OCTADRIVE DSP-CN Datasheet Applies to Part Number: 391030 Octadrive DSP-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may

More information

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel

More information

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual Revision G Copyright 2017 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com E031130243 PROPRIETARY DATA All data

More information

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245 Operation manual 1.0 Introduction 3 2.0 Operation principles 3 3.0 Installation 3 3.1 RS422 Interface Connection 4 3.2 RS485 Interface Connection

More information

T25-35SA Subaudible Tone Decoder

T25-35SA Subaudible Tone Decoder T25-35SA Subaudible Tone Decoder The Mueller Broadcast Design T25-35SA subaudible tone decoder provides a simple and reliable way to detect the 25 and 35 Hz control tones sent by many satellite-delivered

More information

Guardian and DL3282 Modem Interface Technical Service Application Note

Guardian and DL3282 Modem Interface Technical Service Application Note Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio

More information

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3 Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3 PRODUCT FEATURES Hot-pluggable XFP footprint Supports 9.95Gb/s to 10.5Gb/s bit rates Power dissipation

More information

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE

More information

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1586-06 RF Attenuator May 2009 Rev A 1 2 3 12.5 53.5 16.3 MODEL 1586 RF ATTENUATOR CROSS TECHNOLOGIES INC. EXECUTE PS1 PS2 Data, drawings, and other material contained herein are

More information

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection

More information

Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel: Fax: RTB5211 UHF FULL DUPLEX BASE STATION

Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel: Fax: RTB5211 UHF FULL DUPLEX BASE STATION Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel:- 01789 777040 Fax:- 01789 881330 RTB5211 UHF FULL DUPLEX BASE STATION OPERATORS MANUAL Print Date 31/10/2008 Page 1 of 10 E2057-00MA-01.doc

More information

Specifications MPS 602

Specifications MPS 602 Specifications MPS 602 Video VGA Inputs Gain... Unity Bandwidth... 350 MHz (-3 db) Crosstalk... -50 db @ 10 MHz, -30 db @ 100 MHz Switching speed...

More information

Model AAA-1C. Addendum to AAA-1B documentation

Model AAA-1C. Addendum to AAA-1B documentation Model AAA-1C. Addendum to AAA-1B documentation 1. Specifications for Model AAA-1C (11) General Output impedance Power supply (1) Maximal output voltage (10) Physical size 50 Ohms, BNC connector on control

More information

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A. D Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1 Maintenance Manual Printed in U.S.A. This page intentionally left blank 13 PARTS LIST 12 PARTS LIST LBI-31807 11 PARTS LIST 10 SCHEMATIC

More information

Remote Site Monitoring

Remote Site Monitoring Remote Site Monitoring FEATURES AT A GLANCE Codan Radio Communications now offers Remote Site Monitoring options that provide live site information, giving you the power to respond intelligently to communications

More information

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed PB-400-CN Datasheet Applies to Part Number: 590403 IndustryAmp PB-400-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may

More information

Product Specification. 6.1 Gb/s Short-Wavelength SFP+ Transceiver FTLF8526P3BNL

Product Specification. 6.1 Gb/s Short-Wavelength SFP+ Transceiver FTLF8526P3BNL Product Specification 6.1 Gb/s Short-Wavelength SFP+ Transceiver FTLF8526P3BNL PRODUCT FEATURES Up to 6.1 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital diagnostic functions

More information

TETRA 43x0 Four Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet

TETRA 43x0 Four Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet TETRA 43x0 our Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet USER MAUAL 1. General description TETRA 43x0 (4310 for multimode, and 4350 for singlemode) digital-optical multiplexer/demultiplexer

More information

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector I R T Electronics Pty Ltd A.B.N. 000 7 6 Hotham Parade, ARTARMON N.S.W. 06 AUSTRALIA National: Phone: (0) 7 Fax: (0) 7 International: +6 7 +6 7 Email: sales@irtelectronics.com Web: www.irtelectronics.com

More information

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Tel. 0621/ FAX 0621/

Tel. 0621/ FAX 0621/ Änderungen und Irrtümer vorbehalten Video VGA Gain Bandwidth Crosstalk Switching speed Unity 350 MHz (-3 db) -50 db @ 10 MHz, -30 db @ 100 MHz

More information

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL THE AF200A IS AN FM AND FM/SCA PROFESSIONAL STYLE RECEIVER/ MONITOR. IT S MANY APPLICATIONS INCLUDE STATION MONITORING AND EAS MONITORING. The

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

Product Specification. 8 Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1428P3BNV

Product Specification. 8 Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1428P3BNV Product Specification 8 Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1428P3BNV PRODUCT FEATURES Up to 8.5 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital diagnostic

More information

Product Specification. 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCE

Product Specification. 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCE Product Specification 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCE PRODUCT FEATURES Up to 14.025 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital diagnostic

More information

Product Specification Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1426P2BTL

Product Specification Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1426P2BTL a r Product Specification 6.144 Gigabit RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1426P2BTL PRODUCT FEATURES Up to 6.144 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital

More information

RoHS Compliant 1310 nm Multi-mode Transceiver 2 5, LC Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet

RoHS Compliant 1310 nm Multi-mode Transceiver 2 5, LC Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet Features Low power consumption Industry standard 2 5 footprint LC duplex connector Single power supply 3.3 V Differential LVPECL inputs and outputs Class 1 laser product complies with EN 60825-1 Ordering

More information

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node 17.12.2012 1(12) CXX Series User Manual Teleste Corporation CXE880 Fibre node 17.12.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 3 Status monitoring card (optional)...

More information

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems

More information

Product Specification. RoHS-6 Compliant Industrial Temperature 10Gb/s 10km XFP Optical Transceiver FTLX1412D3BTL

Product Specification. RoHS-6 Compliant Industrial Temperature 10Gb/s 10km XFP Optical Transceiver FTLX1412D3BTL Product Specification RoHS-6 Compliant Industrial Temperature 10Gb/s 10km XFP Optical Transceiver FTLX1412D3BTL PRODUCT FEATURES Supports 9.95Gb/s to 10.5Gb/s bit rates Industrial temperature range: -40

More information

Ultrasonic Multiplexer OPMUX v12.0

Ultrasonic Multiplexer OPMUX v12.0 Przedsiębiorstwo Badawczo-Produkcyjne OPTEL Sp. z o.o. ul. Morelowskiego 30 PL-52-429 Wrocław tel.: +48 (071) 329 68 54 fax.: +48 (071) 329 68 52 e-mail: optel@optel.pl www.optel.eu Ultrasonic Multiplexer

More information

Product Specification. RoHS-6 Compliant 10Gb/s 10km Datacom XFP Optical Transceiver FTLX1412D3BCL

Product Specification. RoHS-6 Compliant 10Gb/s 10km Datacom XFP Optical Transceiver FTLX1412D3BCL Product Specification RoHS-6 Compliant 10Gb/s 10km Datacom XFP Optical Transceiver FTLX1412D3BCL PRODUCT FEATURES Supports 9.95Gb/s to 10.5Gb/s bit rates Power dissipation

More information

Series HD 2A, 60Vdc, True Output Status Feedback, Short-Circuit Protected DC Solid-State Relay

Series HD 2A, 60Vdc, True Output Status Feedback, Short-Circuit Protected DC Solid-State Relay Part* Number HD00CFW DESC Drawing Number HD00CFY 88062-008 HD02CFW HD02CFY 88062-006 HD20CFW HD20CFY 88062-004 HD22CFW HD22CFY 88062-002 HD24CFW HD24CFY Relay Description Solid State Relay (SSR) SSR with

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

PCS Electronics

PCS Electronics PCS Electronics www.pcs-electronics.com info@pcs-electronics.com µmax ST-1 High Performance Stereo Encoder With Easy RDS Upgrade Option µmax ST-1 stereo encoder with XLR balanced audio inputs This is our

More information

Models FSW-0010 FSW-0020

Models FSW-0010 FSW-0020 MICROWAVE FREQUENCY SYNTHESIZERS Features: 0.1 to 10 GHz and 0.2 to 20 GHz Coverage 0.001 Hz Resolution Power Calibration and Control 100 μs Frequency Switching Instrument-Grade Spectral Purity QuickSyn

More information

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011 Introduction The ICF-1280I series

More information

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder) ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder) Traditional stepper motor drive systems operate open loop providing position control without feedback. However, because of this,

More information

Product Specification. Industrial Temperature Range 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BTL

Product Specification. Industrial Temperature Range 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BTL Product Specification Industrial Temperature Range 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BTL PRODUCT FEATURES Hot-pluggable XFP footprint Supports 8.5Gb/s and 9.95 through 10.5

More information

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No PLUG N PLAY 1000 1000 WATT DIGITAL FM TRANSMITTER April, 2002 IM No. 597 9972 OPERATION/FEATURE PROGRAMMING. The PNP 1000 allows the user to select many types of different operating parameters and features.

More information

Product Specification. 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCV

Product Specification. 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCV Product Specification 16GFC RoHS Compliant Long-Wavelength SFP+ Transceiver FTLF1429P3BCV PRODUCT FEATURES Up to 14.025 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital diagnostic

More information

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial

More information

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM FULL DUPLEX Radio MODEM Direct Cable Replacement Range 2KM RS232 / RS485 / USB Host Data Rates up to 38,400 Baud RF Data Rates to 115200Kbps Waterproof IP68 Enclosure 8 User Selectable Channels CE Compliant

More information

M Series RF Power Supply (Generator) Analog Interface Connections

M Series RF Power Supply (Generator) Analog Interface Connections M Series RF Power Supply (Generator) Analog Interface Connections The analog interface connector is located on the rear panel of the Radio Frequency Power Supply. Control and status signals for the RF

More information

Product Specification. 10Gb/s, 40km Single Mode, Multi-Rate SFP+ Transceiver FTLX1672D3BTL APPLICATIONS

Product Specification. 10Gb/s, 40km Single Mode, Multi-Rate SFP+ Transceiver FTLX1672D3BTL APPLICATIONS Product Specification 10Gb/s, 40km Single Mode, Multi-Rate SFP+ Transceiver FTLX1672D3BTL PRODUCT FEATURES Hot-pluggable SFP+ footprint 8.5 through 11.3 Gb/s bit rates 40km link length -40/85 C case temperature

More information

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL 2070-6A Manual 1 2070-6A Manual Dual 1200 baud Modem For The 2070 Controller GDI 2070-6A MANUAL This Manual covers Modems with the Serial numbers D700000 and up. 2070-6A Manual 2 GDI 2070-6A Manual This

More information

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial APCSPxxB33xDL10 Product Features Two Bi-Directional transceivers in one SFP package Up to 10.3125Gb/s data links Duplex LC connector Hot-pluggable SFP footprint Uncooled DFB laser transmitter RoHS compliant

More information

Product Specification. 10Gb/s 80km Single Mode SFP+ Transceiver FTLX1871D3BCL APPLICATIONS FTLX1871D3BCL

Product Specification. 10Gb/s 80km Single Mode SFP+ Transceiver FTLX1871D3BCL APPLICATIONS FTLX1871D3BCL Product Specification 10Gb/s 80km Single Mode SFP+ Transceiver FTLX1871D3BCL PRODUCT FEATURES Hot-pluggable SFP+ footprint Supports 8.5 and 9.95 to 11.3 Gb/s 80km link length -5/70 C case temperature range

More information

OC-48 LR-2/STM L-16.2 RoHS Compliant Pluggable SFP Transceiver

OC-48 LR-2/STM L-16.2 RoHS Compliant Pluggable SFP Transceiver OC-48 LR-2/STM L-16.2 RoHS Compliant Pluggable SFP Transceiver PRODUCT FEATURES Up to 2.67Gb/s bi-directional data links Hot-pluggable SFP footprint Built-in digital diagnostic functions Uncooled 1550nm

More information

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder) ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder) Traditional stepper motor drive systems operate open loop providing position control without feedback. However, because of this,

More information

Miniature Synchronous Multipoint Modems

Miniature Synchronous Multipoint Modems ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours

More information

Product Specification. 10Gb/s 80km Multi-Rate XFP Optical Transceiver FTLX1812M3BCL

Product Specification. 10Gb/s 80km Multi-Rate XFP Optical Transceiver FTLX1812M3BCL Product Specification 10Gb/s 80km Multi-Rate XFP Optical Transceiver FTLX1812M3BCL PRODUCT FEATURES Supports 9.95Gb/s to 11.35Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 80km RoHS-6

More information

Instruction Manual Model Block Translator

Instruction Manual Model Block Translator Instruction Manual Model 2083-21-1422 Block Translator October 2018, Rev. 0 1385>2230 G=20 TRX=846.001010 MHz MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings,

More information

DBK45. 4-Channel SSH and Low-Pass Filter Card. Overview

DBK45. 4-Channel SSH and Low-Pass Filter Card. Overview DBK45 4-Channel SSH and Low-Pass Filter Card Overview 1 Hardware Setup 2 Card Connection 2 Card Configuration 2 Configuring DBK45 Filter Sections 3 DaqBook/100 Series & /200 Series and DaqBoard [ISA type]

More information

XFP 10G MM SR. 10Gbps XFP Optical Transceiver, 300m Reach

XFP 10G MM SR. 10Gbps XFP Optical Transceiver, 300m Reach XFP 10G MM SR 10Gbps XFP Optical Transceiver, 300m Reach Features Supports 9.95Gbps to 10.5Gbps bit rates Maximum link length of 300m (50um,MMF,2000MHz.Km) 850nm VCSEL laser and PIN receiver Low power

More information

Instruction Manual Model M Switch, DPDT, Manual Select

Instruction Manual Model M Switch, DPDT, Manual Select Instruction Manual Model 1582-70M Switch, DPDT, Manual Select November 2018 Rev 0 STATUS MODEL 1582 CROSS TECHNOLOGIES INC. MANUAL SELECT POWER Data, drawings, and other material contained herein are proprietary

More information

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008 Features Specially designed for control of brushless motors without encoder Hall-Servo and Encoder-Servo control modes Motors supported: - Brushless 60/120 commutated (AC) - Brush-commutated (DC) Up to

More information

FTLX14. 10Gb/s 10km. Datacom. Product. bit rates* -5 C to 75 C APPLICATIONS. of 10km Uncooled. 10G Fibre. Channel 10G CPRI. Small Form comply with

FTLX14. 10Gb/s 10km. Datacom. Product. bit rates* -5 C to 75 C APPLICATIONS. of 10km Uncooled. 10G Fibre. Channel 10G CPRI. Small Form comply with F i n i s a r Product Specification 10Gb/s 10km Datacom XFP Optical Transceiver FTLX1413D3BCL PRODUCT FEATURES Supports 8.5Gb/s to 10.5Gb/s bit rates* Power dissipation

More information

Digital Microwave Radios

Digital Microwave Radios CM Digital Microwave Radios Operating at 6, 7, 8 & 11 GHz With Capacities of 4, 8, 16E1 E3, STM-1 & 2x100BaseT The CM offers bandwidth efficient long haul data transmission for common carrier, cellular

More information

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd Balanced / Unbalanced Line Audio Interface Amplifiers User Manual Revision 02 BALANCED / UNBALANCED LINE AUDIO INTERFACE AMPLIFIERS Revision History: Revision Date By Change Description Applicable to:

More information

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j. User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS

More information

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP Features Motors supported: - Panasonic A and S series - Brushless 60/120 commutated - Brush-commutated (DC) motors Up to 20A peak, 12A continuous output current 12 to 90VDC power supply Separate motor

More information

User Guide. Version 1.0.

User Guide. Version 1.0. User Guide Version 1.0 www.focusrite.com TABLE OF CONTENTS OVERVIEW.... 3 Introduction...3 Features.................................................................... 3 Box Contents...4 Hardware Features...4

More information

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels Copyright 2006, American Fibertek, Inc. 0307JD Table of Contents Functional Description... 3 Installation...

More information

Universal RS232/CMOS to RS422/RS485 Converter

Universal RS232/CMOS to RS422/RS485 Converter TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.

More information

Product Specification

Product Specification Product Specification 8.5 Gb/s Short-Wavelength SFP+ Transceiver FTLF8528P3BxV PRODUCT FEATURES Up to 8.5 Gb/s bi-directional data links Hot-pluggable SFP+ footprint Built-in digital diagnostic functions

More information

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...

More information

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver PRODUCT FEATURES Hot-pluggable XFP footprint Supports 9.95Gb/s to 10.5Gb/s bit rates Power dissipation

More information

Instruction Manual Model

Instruction Manual Model Instruction Manual Model 2099-24 10MHz Source/Inserter, Redundant Power August 2016, Rev. 0 MODEL 2099 SOURCE / INSERTER ALARM DC ON REF ON LNB1 LNB2 MENU EXECUTE LNB1 +24.2V @ 0.249A LNB2 +23.8V @ 0.251A

More information

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting. RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate 115.2 protocol

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back 1/7 DPA602 Multi-Channel Network Amplifier Features Configurations 2 x 300 Watt 70V / 100V (Factory Default) 4 x 150 Watt @ 4Ω 1 x 300 Watt 70V / 100V & 2 x 150 Watt @ 4Ω No Computer Required to Operate

More information

F2A3X Frequency to Analog Converter Module

F2A3X Frequency to Analog Converter Module the professional s choice F2A3X Frequency to Analog Converter Module Instruction Manual MONARCH INSTRUMENT 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com

More information

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D Overview Multi-channel power amplifiers with features designed specifically to benefit installation sound systems. Features Eight-channel power amp that can operate in both high-impedance (70V/100V line)

More information

XFP 10G SR 03km LC Optical Transceiver

XFP 10G SR 03km LC Optical Transceiver Product Specification 1. Features Supports 9.95Gbps to 10.5Gbps bit rates Maximum link length of 300m (50um, MMF, 2000MHz.Km) 850nm VCSEL laser and PIN receiver Low power consumption

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

GBS-9280-CXX0 5V / CWDM / Gb/s Single-Mode Gigabit Interface Converter (GBIC)

GBS-9280-CXX0 5V / CWDM / Gb/s Single-Mode Gigabit Interface Converter (GBIC) **** 5V / CWDM / 2.125 Gb/s Single-Mode Gigabit Interface Converter (GBIC) ** FEATURES l 18-Wavelength CWDM GBIC Transceivers l 2.5 Gbps Bi-directional Data Links l Compliant with 1X / 2X Fibre Channel

More information

CXD-Q 8-Channel Amplifier

CXD-Q 8-Channel Amplifier CXDQ 8Channel Amplifier Quick Start Guide EXPLANATION OF TERMS AND SYMBOLS The term WARNING! indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily

More information

maxon document number:

maxon document number: maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

VX-3000 Series Voice Alarm and Public Address System

VX-3000 Series Voice Alarm and Public Address System VX-3000 Series Voice Alarm and Public Address System VX-3000 SERIES Combined highly integrated voice alarm and public address system. The issue of security is more than ever important. Our VX-3000 is a

More information

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER CTENTS General functionality and features of the equipment. Technical specifications. Application. Connection

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual Revision A March 2015 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958

More information

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter User manual Multimode Fibre-Optic to Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-7021_v1.02_en Contents 1.GENERAL INFORMATION... 3 1.1.WARRANTED INFORMATION... 3 1.2.GENERAL CONDITIONS FOR SAFE

More information

Model LIA100. Lock-in Amplifier

Model LIA100. Lock-in Amplifier Model LIA100 Lock-in Amplifier Operations Manual Thorlabs, Inc 435 Route 206 Newton, NJ 07860 P-(973) 579-7227 F-(973) 300-3600 www.thorlabs.com Doc. Page 1 of 10 Table of Contents Chapter Description

More information

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL-0040-01 USER MANUAL The QP-FSPLL-0040-01 is a low-phase noise wideband synthesizer operating from 50 MHz to 40 GHz with a nominal output power of +15 dbm. The synthesizer

More information

OEM PRODUCTS WIRELESS WORLD LOCAL SOLUTION

OEM PRODUCTS WIRELESS WORLD LOCAL SOLUTION OEM PRODUCTS 2008 www.satel.com 2 M3 The M3 is a small and light-weight radio modem designed for integration into the user s terminal equipment. The modem and transceiver are enclosed in a steel or aluminium

More information

Product Specification

Product Specification Product Specification Extended Temperature 10Gb/s 850nm SFP+ Datacom Transceiver FTLX8574D3BNL PRODUCT FEATURES Hot-pluggable SFP+ footprint Supports 9.95 to 10.5 Gb/s bit rates* Power dissipation < 1W

More information

Maintenance Manual ERICSSONZ LBI-31552E

Maintenance Manual ERICSSONZ LBI-31552E E Maintenance Manual TONE REMOTE CONTROL BOARD 19A704686P4 (1-Frequency Transmit Receive with Channel Guard) 19A704686P6 (4-Frequency Transmit Receive with Channel Guard) ERICSSONZ Ericsson Inc. Private

More information

Radiated immunity test system 6 GHz

Radiated immunity test system 6 GHz its 6006 The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the

More information

ELECTRONICS FOR PULSE PICKERS

ELECTRONICS FOR PULSE PICKERS Rev. 3.07 / 2014 04 10 ELECTRONICS FOR PULSE PICKERS TABLE OF CONTENTS Description... 2 High voltage switches... 3 Appearance / dimensions... 3 Power ratings... 3 Interfaces... 4 Specifications... 6 How

More information

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum. The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum. L3 (L3 T&RF) DR-2000 receiving unit incorporates a high-performance

More information