S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS
|
|
- Rosemary Burke
- 5 years ago
- Views:
Transcription
1 S5X Mobile Microcomputer Technical Information ,5 POWER SYSTEM 82,25 77,75 MODE STATUS 9 164,5,3 AMP Stecker AMP Connector ,5
2 Overview DESCRIPTION The Sauer-Danfoss S5X Mobile Microcomputer is a digital electronic, designed for open loop as well as closed loop mobile off-road system applications. Specific for hydraulic driven forestry systems and road building systems. State of art controls in mobile applications driving rotary and linear actuators (hydrostatic transmissions, hydraulic cylinders etc.) are to be more flexible and intelligent. The robust design of the S5X digital electronic series provides best for this. The design provides the required performance for a mobile environment and high performance, 16 bit mirocontroller provides the capability for future expansion. It is possible to load several software programs via RS232 interface for various series without any hardware change. This feature makes it possible for an unexperienced operator to use standard hardware for different applications while the appropriate software is selected. The S5X software and hardware is designed for easy communication between the controller. Especially developed tools can be used to optimize the performance during production. This facility simplifies start-up, field service and stock. FEATURES Environmentally proofed for mobile applications. Supply voltage 12 V DC or 24 V DC. Software changes without hardware operations. Individual setup per software possible. Visual error output (Blink code for red Error LED). Diagnostic functions and emergency routines. Communication between S5X and Laptop via RS232. Update software download. TECHNICAL DATA Supply voltage: 12 V DC or 24 V DC Sensor voltage: 5 V DC up to 200 ma LED outputs: 2 (under software control). 2 (for internal voltages). All visible from outside the enclosure. Communication: RS232 full buffered. CAN Interface: Standard Specification V2.0 Part B (active). Physical layer: Standard ISO (High-Speed) Electrical connections: 42pin board-mounted AMP I/O connector. 16pin board-mounted AMP I/O connector for communication. Operation temperature: -40 C to +70 C Moisture: Protected against 95 % relative humidity and high pressure washdowns. Vibration: 5 to 2000 Hz with resonance dwell for 1 million cycles for each resonant point run from 1 to gs. Shock: 50 gs for 11 ms in all 3 axes for a total of 18 shocks. Electrical: The S5X is protected for short circuits to ground. The supply voltage must only be connected to the pins defined in a system connection diagram. Otherwise damage to the controller is possible. Withstands reverse polarity, over voltage, voltage transients, static discharge, EMI/RFI and load dump. 2001, Sauer-Danfoss Sauer-Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are properties of the respective companies. Sauer-Danfoss and the Sauer-Danfoss logotype are trademarks of the Sauer-Danfoss Group. All rights reserved. 2 BLN E Rev. E 12/2001
3 Technical Data S5X-11 G2 AMP K167C I/O Functions Description Battery input current max. 6 A Digital inputs high side switching. 5 Analog inputs 0 V DC to 5 V DC 3 Frequency inputs 1x 2-wire PPU and 2x 3-wire PPUs configured. 0 to khz. 2 Current feedback inputs high current measuring up to 2 A. 3 Proportional outputs unidirectional PWM outputs. 2 A high side switching. Can be used as digital outputs. 2 Actuator outputs bidirectional PWM outputs with internal current feedback. 4 Digital outputs 2 A high side switching. Controller Siemens SAF C167 CR-LM Memory Flash Memory: 1MByte RAM: 256kByte I 2 C EEPROM: 2kByte CAN Interface as described above. S5X-12 G2 AMP K196 I/O Functions Description Battery input current max. 6 A 6 Digital inputs high side switching. 4 Analog inputs 0 V DC to 5 V DC 3 Frequency inputs 1x 2-wire PPU and 2x 3-wire PPUs configured. 0 to khz. 3 Proportional outputs unidirectional PWM outputs. 2 A high side switching. 3 Gear switch outputs 4 A low side switching. 4 Digital outputs 2 A high side switching. Controller Intel 80C196 KC Memory Flash Memory: 128kByte RAM: 8kByte I 2 C EEPROM: 2kByte S5X-15 G2 AMP K167C I/O Functions Description Battery input current max. 12 A Digital inputs high side or low side switching. Selectable via software. Analog inputs 0 V DC to 5 V DC 6 Frequency inputs 2- or 3-wire PPU. Selectable via software. 0 to khz. Proportional outputs unidirectional PWM outputs. or EDC outputs 2 A high side switching. max. 8 prop. outputs or max. 6 EDC outputs or mixed. 2 Actuator outputs can be used as digital outputs. 4 Digital outputs 2 A high side switching. Controller Siemens SAF C167 CR-LM Memory Flash Memory: 1MByte RAM: 256kByte I 2 C EEPROM: 2kByte CAN Interface as described above. BLN E Rev. E 12/2001 3
4 Dimensions LED OVERVIEW ,5 7 6 POWER SYSTEM ,25 77,75 MODE STATUS 9 164,5, ,5 1 S5X 2 Mounting slots 3 AMP connectors 4 Diagnostic LED red Error check (STATUS) Lights up if an error is detected. 5 Diagnostic LED yellow Software check (MODE) Flashes with approx. 0.5Hz (slow), if the program is running fine. Flashes with approx. 5Hz (fast), if no program is loaded. Shining if in setup mode. 6 Diagnostic LED green 5V DC internal (SYSTEM) Lights up if 5V DC internal is O.K. 7 Diagnostic LED green Battery after ignition switch (POWER) Lights up if the battery voltage is connected after ignition. S01752a 4 BLN E Rev. E 12/2001
5 Environmental Tests ENVIRONMENTAL TESTS EMC-Standards, MCES015 Immunity Test principle Severity level Radiation (stripline) ISO : V/m (1 MHz MHz) Radiation (antenna) ISO : V/m (200 MHz - 00 MHz) ESD ISO TR 605: kv / 8 kv Impulsive disturbances DIN part 1:.1992 pulse 1: -200 V applied to supply leads pulse 2: +0 V pulse 3a: -200 V pulse 3b: +200 V pulse 4: Us -16 / -7 V pulse 5: +200 V Impulsive disturbances DIN part 3: pulse 1: -60 V applied to transmitter pulse 2: +30 V and signal leads pulse 3a: -80 V pulse 3b: +80 V Emission Test principle Limit value met (Radio interference) Electrical disturbance Directive 95/54/EEC EUB/narrowband field strength EUB/broadband Disturbance voltage DIN part 3: Degree of suppression 5 (0,15 MHz - 30 MHz) Degree of suppression 4 (87,5 MHz - 8 MHz) Mechanical Standards, MCES015 Mechanical vibration Test principle Severity level Random DIN IEC h in each of 3 orthogonal axes at 5.58 g 50 Hz Hz Resonance Search DIN IEC Hz Hz at the rate of 1 octave per minute 4 g throughout sweep Resonance Dwell time DIN IEC g throughout sweep 5 minutes dwell time Mechanical Shock DIN IEC shocks in each direction of the three major orthogonal axes 50 g throughout sweep with 11 ms Temperature test Test principle Severity level Temperature shock DIN IEC C max. temperature -40 C min. temperature 1 h dwell time 24 h test cycle time Salt test Test principle Severity level Salt spray DIN IEC % NaCl at 35 C / 72 h BLN E Rev. E 12/2001 5
6 OUR PRODUCTS Hydrostatic transmissions Hydraulic power steering Electric power steering Closed and open circuit axial piston pumps and motors Gear pumps and motors Bent axis motors Radial piston motors Orbital motors Transit mixer drives Planetary compact gears Proportional valves Sauer-Danfoss Hydraulic Power Systems Market Leaders Worldwide Sauer-Danfoss is a comprehensive supplier providing complete systems to the global mobile market. Sauer-Danfoss serves markets such as agriculture, construction, road building, material handling, municipal, forestry, turf care, and many others. We offer our customers optimum solutions for their needs and develop new products and systems in close cooperation and partner ship with them. Sauer-Danfoss specializes in integrating a full range of system components to provide vehicle designers with the most advanced total system design. Sauer-Danfoss provides comprehensive worldwide service for its products through an extensive network of Authorized Service Centers strategically located in all parts of the world. Directional spool valves Cartridge valves Hydraulic integrated circuits Hydrostatic transaxles Integrated systems Fan drive systems Electrohydraulic controls Digital electronics and software Battery powered inverter Sensors Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 500, USA Phone: , Fax: Sauer-Danfoss (Neumünster) GmbH & Co. OHG Postfach 2460, D Neumünster Krokamp 35, D Neumünster, Germany Phone: , Fax: Sauer-Danfoss (Nordborg) A/S DK-6430 Nordborg, Denmark Phone: , Fax: Sauer-Danfoss (US) Company 3500 Annapolis Lane North Minneapolis, MN 55447, USA Phone: , Fax: BLN E Rev. E 12/2001
POWER SYSTEM MODE STATUS
S1X Mobile Microcomputer Technical Information 174 155 55,75 POWER SYSTEM MODE STATUS 60,25 8,5 8,5 10 9 10 123,5 10,5 AMP Stecker AMP Connector 1 14 15 28 55 29 42 Overview DESCRIPTION The Sauer-Danfoss
More informationMCX103A Non-Contact Rotary Position Sensor. Technical Information
MCX103A Non-Contact Rotary Position Sensor Technical Information Revisions Revision History Table of Revisions Date Page Changed Rev 07 Dec 2010 Cover PLUS+1 Compliant logo AB 28 Sep 2010 Replaces BLN-95-8991
More informationMP1 Pumps Non-Feedback Proportional Electric (NFPE) Control
Electrical Installation MP1 Pumps Non-Feedback Proportional Electric (NFPE) Control powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 2018 add control current table
More informationS42 Pump Electrical Displacement Control (EDC)
MAKING MODERN LIVING POSSIBLE Electrical Installation S42 Pump Electrical Displacement Control (EDC) powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2015 Converted
More informationTechnical Information Output Configurations for PLUS+1 Controllers powersolutions.danfoss.com
MAKING MODERN LIVING POSSIBLE Technical Information Output s for PLUS+1 Controllers powersolutions.danfoss.com Output s for PLUS+1 Controllers Revisions Revision History Table of Revisions Date Page Changed
More informationH1B Motor Electric Proportional Control L1, L2
MAKING MODERN LIVING POSSIBLE Electrical Installation H1B Motor Electric Proportional Control L1, L2 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev July 2015 Converted
More informationS45 Pump Electric Proportional Control
Electrical Installation S45 Pump Electric Proportional Control powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev August 2016 Updated graphs and changed to Engineering Tomorrow
More informationSensor EMD Speed Sensor
MAKING MODERN LIVING POSSIBLE Electrical Installation Sensor powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2015 Minor layout revision AC December 2014 Updated
More informationUltrasonic Controller/Sensor. Technical Information
Ultrasonic Controller/Sensor Technical Information Revisions Revision History Table of Revisions Date Page Changed Rev 08 Mar 2011 Cover Added PLUS+1 Compliant AB 24 Feb 2011 Replaces BLN-95-9078 AA 2011
More informationTech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com
MAKING MODERN LIVING POSSIBLE Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com About this manual This publication is intended to share circuits, products and other useful
More informationACX104B Potentiometer Rotary Position Sensor. Technical Information
X104 Potentiometer Rotary Position Sensor Technical Information X104 Potentiometer Rotary Position Sensor Revisions Revision History Table of Revisions Date Page hanged Rev 29 July, 2010 Initial release
More informationSensors Q625A Remote Setpoint Module
MAKING MODERN LIVING POSSIBLE Technical Information Sensors powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev November 2015 Converted to Danfoss layout 0001 September 2010
More informationElectrohydraulic Actuators PVEA/H/S
MAKING MODERN LIVING POSSIBLE Electrical Installation Electrohydraulic Actuators PVEA/H/S powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2015 Minor layout revision
More informationSensors ACE100B DC Millivolt Input Amplifier
MAKING MODERN LIVING POSSIBLE Technical Information Sensors ACE100B DC Millivolt Input Amplifier powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev November 2015 Converted
More informationElectrohydraulic Actuator Type PVEP / PVEP-F
MAKING MODERN LIVING POSSIBLE Technical Information Electrohydraulic Actuator Type PVEP / PVEP-F powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2014 Converted to Danfoss
More informationMAKING MODERN LIVING POSSIBLE. Electrical Installation. Pulse Pickup KPP PPU. powersolutions.danfoss.com
MAKING MOERN LIVING POSSIBLE Electrical Installation Pulse Pickup powersolutions.danfoss.com Revision history Table of revisions ate Changed Rev July 2015 Converted to anfoss layout BA April 2007 First
More informationMAKING MODERN LIVING POSSIBLE. Electrical Installation. M46 Pumps HC EDC. powersolutions.danfoss.com
MAKING MODERN LIVING POSSIBLE Electrical Installation M46 Pumps HC EDC powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2015 Minor layout revision AB June 2014
More informationTechnical Information. FDCA Fan Drive Control Assembly
Technical Information Fan Drive Control Assembly CONTENTS Description...3 Features...3 Theory of Operation... 4,5 Technical Data... 5, Dimensions...7 Ordering Nomenclature Chart...8 Accessories...9 Service
More informationELECTRONIC CONTROL DEVICES
ELECTRONIC CONTROL DEVICES INDEX Subject Page INTRODUCTION... 3 ELECTRONIC CONTROL UNIT... 4 SPEED SENSOR... 6 PRESSURE SENSOR... 8 AIR/FLUID TEMPERATURE SENSOR... 9 SWIVEL ANGULAR SENSOR MVP SERIES...10
More informationMCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)
DESCRIPTION The MCHXXX Control Handle is intended for open-loop control of electrohydraulic proportional valves utilizing pulse width modulated (PWM) outputs to optimize valve performance. Adjustments
More informationACTUATOR LA12/LA12 PLC
PRODUCT DATA SHEET ACTUATOR LA12/LA12 PLC Features: 12/24 V DC permanent magnetic motor Max. thrust 75 N Reinforced glass fibre piston rod Compact design Protection class: IPX1 or IP66 Colour: black Straight
More informationhigh grade, temperature resistant plastic, Thermoplast with brass inserts
NOVOHALL Rotary Sensor touchless technology transmissive Series RFD4000 analog Special features fully touchless - no shaft or seals to wear measure directly through any non-ferromagnetic material electrical
More informationMCHXXX Control Handle
Technical Information Control Handle powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2017 Potentiometer Models with 1K Ohm table updated 0601 October 2016 Minor
More informationAnalog amplifier RA. RE Edition: Replaces:
Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable
More informationAnalog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier RA RE 95 230/03.06 1/12 replaces: RE 95 022 RE 95 023 RE 29 874 RE 29 875 Technical Data
More informationDVC700 Series Programmable System Controller
LC Programmed with HCT s Intella Software Suite 14 I/O (8 inputs & 6 outputs), 1 CAN interface Supply voltage 9-30Vdc The is a robust programmable controller for solenoid-operated proportional valves.
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog
NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,
More informationhigh grade, temperature resistant plastic, Thermoplast with brass inserts
NOVOHALL Rotary Sensor touchless technology transmissive Series RFD-4000 Special features fully touchless - no shaft or seals to wear measure directly through any non-ferromagnetic material electrical
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationPressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that
More informationPressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350
Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures
More informationActuator LA12 PRODUCT DATA SHEET
PRODUCT DATA SHEET Actuator LA12 Thanks to its small size and outstanding performance, the actuator LA12 provides a practical and cost-effective alternative to small-scale traditional hydraulic and pneumatic
More informationBH series Paddle joystick controllers
Distinctive features and specifications Hall effect joystick and switch function Sculpted ergonomic rubber grip 5V operation - standard dual redundant outputs Analog or PWM outputs Custom lever colors
More informationDVC700 Series Programmable System Controller
Programmed with HCT s Intella Software Suite 23 I/O (14 inputs & 9 outputs), 2 CAN interfaces Supply voltage 9-30Vdc The is a robust programmable controller for solenoid-operated proportional valves. It
More informationAnalog signal converters CC-E I/I
2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage
More informationTECHNICAL PRODUCT DATASHEET
FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10
More informationOvercurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
More informationNOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog
NOVOHALL Rotary Sensor touchless technology transmissive Series RFC4800 analog The RFC 4800 utilizes a separate magnet or magnetic position marker, attached to the rotating shaft to be measured. The orientation
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationTest Specification for Type Approval
A2 (1991) (Rev.1 1993) (Rev.2 1997) (Rev. 2.1 July 1999) (Rev.3 May 2001) (Corr.1 July 2003) (Rev.4 May 2004) (Rev.5 Dec 2006) (Rev.6 Oct 2014) Test Specification for Type Approval.1 General This Test
More informationBL series Miniature paddle joystick controllers
Distinctive features and specifications Hall effect joystick and switch function Sculpted ergonomic rubber grip 5V operation - standard dual redundant outputs Analog or PWM outputs Custom lever colors
More informationController for the Implementation of a Central or Decentralized Electrohydraulic System
EFX 1624m Electronic Controller Programmed with Eaton CONTROL F(x) Software to IEC 61131-3 Standard 2nd CAN interface for gateway function according to SAE J1939 Supply voltage 10...32V DC Technical Data
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental
NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional
More informationSIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay
Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which
More informationNOVOTURN Multiturn Sensor non-contacting. Series RSM-2800
NOVOTURN Multiturn Sensor non-contacting Series RSM-2800 Special features Non-contacting, magnetic Long life Electrical range 720 up to 5760 in 360 -steps available (2 to 16 turns) True-Power-On System:
More informationT40FH. Torque flange. Special features. Data sheet
T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationNOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900
NOVOHALL Rotary Sensor touchless transmissive Series RFX-6900 Special features Very robust design to extreme environmental conditions Touchless hall technology Electrical range up to 360, in single and
More informationPotential Applications
SNDH-T4L-G01 Quadrature speed and direction sensor Actual product appearance may vary. Features Hall-effect magnetic sensing technology Advanced performance dynamic offset self calibration Air gap up to
More informationOIS25. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information
Optical smart sensor for hydraulic cylinders General Description is a patented smart optical device, which is usually combined with a hydraulic steering cylinder. The main application is on rough terrain
More informationGlobal Application Development Centers. Creating and proving solutions to customer challenges. A truly global team working for. you.
Global Application Development Centers Creating and proving solutions to customer challenges A truly global team working for you. ACHIEVING SUCCESS, Thriving in today s marketplace is more than meeting
More informationT40FM. Data Sheet. Torque flange. Special features. Overall concept. B en
T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationPenny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272
Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272 No-Contact Hall-effect technology Wear-Free unlimited mechanical life Simple mounting, low-profile design Measurement angle 20-360 5V or
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationPOSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire
POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationT40B. Torque Flange. Special features. Data sheet. Overall concept
T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal
More informationNPN PNP NPN PNP NPN PNP
Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles
More informationNOVOHALL Rotary Sensor non-contacting. Series RSX-7900
NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in
More information2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals
2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals Technical information Version 08.09 General information Application approved speed sensor based on magnetic measurement principle
More informationACTUATOR LA36 PRODUCT DATA SHEET
PRODUCT DATA SHEET ACTUATOR LA36 Features: 12, 24 or 36 V DC Permanent magnetic motor with resetable thermal overload protection Max. thrust 17 N, 26 N, 45 N or 68 N depending on gear ratio and spindle
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC-2800
NOVOHALL Rotary Sensor non-contacting Series RSC-2800 Special features Non-contacting, magnetic technology Measuring range up to 360 Available with push-on coupling or marked shaft Simple mounting Protection
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More information6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)
6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationTemposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors M-Series Mobile Hydraulic in-cylinder Sensor Model MH PWM Output Data Sheet SENSORS Document Part Number 551119 Revision B M-Series
More informationQuadrature Speed and Direction Sensors. SNG-Q Series. Datasheet
Quadrature Speed and Direction Sensors SNG-Q Series Datasheet SNG-Q Series Honeywell s SNG-Q Series Quadrature Speed and Direction Sensor with 4-wire quadrature sensing is the first release of the new
More informationRT200 Series Single-axis Industrial Joystick. RunnTech
Product Features Potentiometer sensor or ; All metal construction, fully sealed design; Available with various shape mulitfunction grips; Mechanical spring-return to center or Friction-hold operation;
More informationPressure transmitter AKS 32 and AKS 33
Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS
More informationOnline data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS
Online data sheet MAX48N-31V10K12500 MAX48 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Safety-related parameters Ordering information Other models and accessories
More informationWimesure 54, rue de Versailles CHEVREUSE Tél Fax
No-contact, Hall-effect technology Wear free unlimited mechanical life Simple mounting, low-profile design Measurement angle 20-360 5V or 9-30V supply options Dual redundant outputs Analog output 0.5-4.5V
More informationSPECIFICATION OUTLINE
ECO DESCRIPTION DTE BY 001 5479 PRODUCTION RELESE 10/02/2009 GF 5663 OMIT PRODUCT ND SERIL NUMBER LBEL DETIL REPLCE PPROPRITE SE REFERENCES WITH ISO REFERENCES ENHNCE REGULTORY REQUIREMENTS TBLE 5/26/2010
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationAUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX
AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX Introduction The CAB family is for battery monitoring applications where high accuracy and very low offset are required. Features Transducer
More informationInfocal 9 Energy calculator
Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationApplications: oil and gas equipment automation; off-highway machine automation; agricultural equipment
Features: 6 Universal Signal Inputs are user configurable as: o 0-5V, 0-10V, 4-20mA or 0-20mA o 20Ω to 250 kω Resistive o 1 Hz to 10 khz PWM o Digital o Three of the inputs can be configured as a pulse
More informationKNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION
More informationPART NUMBERING SYSTEM
Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH1DRW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with
More informationPFM 5000 Measuring Instrument
Application Multi branch systems The PFM 5000 is able to calculate complicated multi branch heating systems by simulating the hydraulic system using balancing calculations based on readings in each branch.
More informationPART NUMBERING SYSTEM
Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective
More informationVert-X 27E - 5V / % Ub. Applications Harvesting machine Fork lift Hydraulic pump
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearitiy (without misalignment) % of meas. range ±0.3 ±0.3 Indep. linearitiy (with allowed misalignment @ 360 ) %
More informationOnline data sheet NT NT8 CONTRAST SENSORS
Online data sheet NT8-02412 NT8 A B C D E F H I J K L M N O P Q R S T Detailed technical data Features Dimensions (W x H x D) Ordering information Other models and accessories Sensing distance 9 mm 1)
More informationAccutech AM20. Wireless acoustic monitor field unit
Accutech AM20 Wireless acoustic monitor field unit 1 The Accutech AM20 wireless acoustic monitor field unit monitors pressure relief valves, steam traps, automatic tank cleaning (CIP) systems, and other
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationPOSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire
Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute
More informationAUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S
AUTOMOTIVE CURRENT TRANSDUCER Introduction The HAH1DR family is for the electronic measurement of DC, AC or pulsed currents in high power automotive applications with galvanic isolation between the primary
More informationSpeed sensor DSA series 12
Speed sensor DSA series 12 RE 95133 Edition: 01.2015 Replaces: 07.2014 Hall-effect sensor for contactless speed measuring For installation in axial piston units Two versions With two frequency signals
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S03 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.
More informationConnection to the sensor is with simple flying leads for customer termination. 1 Page NRH300DP Rev B 09/15
No-contact, Hall-effect technology Wear free unlimited mechanical life Simple mounting, low-profile design Measurement angle 20-360 5V or 9-30V supply options Dual redundant outputs Analog output 0.5-4.5V
More information