Endovascular aortic repair Fenestrated

Size: px
Start display at page:

Download "Endovascular aortic repair Fenestrated"

Transcription

1 Endovascular aortic repair Fenestrated Zenith ENDOVASCULAR GRAFTS MEDICAL

2 Active Fixation Our anchoring barbs are the industry standard for design and migration resistance. Radial Force Self-expanding z-stents provide radial force, added stability and optimal graft-to-vessel apposition. Columnar Strength Long main-body design features a time-tested balance of length, stability and flexibility. ARC Technology Demand systemic migration resistance. The three features that make up ARC Technology active fixation, radial force and columnar strength work in unison to give all Zenith AAA endovascular grafts unrivaled migration resistance. In the U.S. Zenith Fenestrated Clinical Study, there were two reports of migration, both in patients with evidence of disease progression at follow-up (without aneurysm pressurization).

3 Endovascular aortic repair Fenestrated Zenith ENDOVASCULAR GRAFTS Fenestrated...4- Zenith Fenestrated AAA Endovascular Graft Overview Graft specifications and ordering information...- Zenith Spiral-Z AAA Iliac Leg Graft Graft specifications and ordering information...2- Zenith Alignment Stent Ordering information... Accessories...-8 MEDICAL

4

5 Experience patient-specific precision. Zenith Fenestrated AAA ENDOVASCULAR GRAFT Offer patient-specific endovascular solutions to more of your AAA patients. Zenith Fenestrated is the first stent graft designed for patients with infrarenal necks as short as 4. Patient-specific precision Achieve a seal just below the renal arteries without the risk of occluding any vessels thanks to precisely positioned fenestrations and scallops for the SMA and renal arteries. Scallops 0 wide and -2 high Small fenestrations wide and or 8 high Large fenestrations 8-2 in diameter scallop small fenestration large fenestration Patient-specific modularity Custom tailor Zenith Fenestrated further with our extensive selection of individual components, including the Zenith Spiral-Z AAA Iliac Leg Graft. Zenith Spiral-Z provides even more treatment options for your patients with tortuous anatomy, since it has enhanced flexibility and is available in a wide range of lengths and diameters. ARC Technology Experience systemic migration resistance due to the time-tested combination of active fixation, radial force, and columnar strength. Precision delivery H&L-B One-Shot introduction system Diameter-reducing ties facilitate placement and visceral vessel cannulation by constraining the graft diameter during deployment. This allows you to manipulate Zenith Fenestrated even when it s semi-deployed. Flexor introducer sheath facilitates precise delivery and placement because of its kinkresistant technology and PTFE-coated lumen. AQ hydrophilic coating facilitates precise delivery by dramatically reducing surface friction. Trigger wires facilitate staged deployment to ensure precise placement. Gold markers facilitate precise placement. MEDICAL 5

6 Zenith Fenestrated AAA - Graft specifications Proximal body grafts One proximal internal stent 24, 2, 28, 0, 2 24, 2, 28, 0, 2 24, 2, 28, 0, 2 24, 2, 28, 0, , 4, 4, 4, Note: Black numbers on stents indicate stent lengths in millimeters. Red numbers indicate gap lengths in millimeters. Fabric gaps may vary. H&L-B One-Shot introduction system for proximal body grafts 24-4 grafts: 20 Fr (.7) ID/7.7 OD grafts: 22 Fr (7.) ID/8.5 OD 9 cm 50 cm

7 Zenith Fenestrated AAA - Component ordering information Order Number Reference Part Number Proximal Body Diameter Proximal Body Length Introducer Sheath ID/OD Fr ()/ Proximal body diameter One Proximal Internal Stent 24 Diameter G2502 ZFEN-P R (.7)/7.7 G2507 ZFEN-P R (.7)/7.7 G252 ZFEN-P R (.7)/7.7 G25 ZFEN-P R (.7)/7.7 Proximal body length 2 Diameter G250 ZFEN-P--2-7-R (.7)/7.7 G2508 ZFEN-P--2-9-R (.7)/7.7 G25 ZFEN-P--2-0-R (.7)/7.7 G258 ZFEN-P--2-2-R (.7)/ Diameter G2504 ZFEN-P R (.7)/7.7 G2509 ZFEN-P R (.7)/7.7 G25 ZFEN-P R (.7)/7.7 G259 ZFEN-P R (.7)/7.7 Proximal body diameter 0 Diameter G2505 ZFEN-P--0-7-R (.7)/7.7 G250 ZFEN-P--0-9-R (.7)/7.7 G255 ZFEN-P--0-0-R (.7)/7.7 G2520 ZFEN-P--0-2-R (.7)/7.7 2 Diameter G250 ZFEN-P--2-7-R (.7)/7.7 G25 ZFEN-P--2-9-R (.7)/7.7 G25 ZFEN-P--2-0-R (.7)/7.7 G252 ZFEN-P--2-2-R (.7)/7.7 4 Diameter G2522 ZFEN-P R (.7)/7.7 G2524 ZFEN-P R (.7)/7.7 G252 ZFEN-P--4--R 4 20 (.7)/7.7 G2528 ZFEN-P R (.7)/7.7 Proximal body length Diameter G252 ZFEN-P---84-R (7.)/8.5 G2525 ZFEN-P---99-R (7.)/8.5 G2527 ZFEN-P----R 22 (7.)/8.5 G2529 ZFEN-P---29-R (7.)/8.5 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. 7

8 Zenith Fenestrated AAA - Graft specifications Proximal body grafts Two proximal internal stents 24, 2, 28, 0, 2 24, 2, 28, 0, 2 24, 2, 28, 0, , 4, 4, Note: Black numbers on stents indicate stent lengths in millimeters. Red numbers indicate gap lengths in millimeters. Fabric gaps may vary. H&L-B One-Shot introduction system for proximal body grafts 24-4 grafts: 20 Fr (.7) ID/7.7 OD grafts: 22 Fr (7.) ID/8.5 OD 9 cm 50 cm 8

9 Zenith Fenestrated AAA - Component ordering information Proximal body diameter Order Number Reference Part Number Two Proximal Internal Stents Proximal Body Diameter Proximal Body Length Introducer Sheath ID/OD Fr ()/ 24 Diameter G250 ZFEN-P R (.7)/7.7 G255 ZFEN-P R (.7)/7.7 G2540 ZFEN-P R (.7)/7.7 2 Diameter G25 ZFEN-P R (.7)/7.7 G25 ZFEN-P R (.7)/7.7 G254 ZFEN-P R (.7)/7.7 Proximal body length 28 Diameter G252 ZFEN-P R (.7)/7.7 G257 ZFEN-P R (.7)/7.7 G2542 ZFEN-P R (.7)/7.7 0 Diameter G25 ZFEN-P R (.7)/7.7 G258 ZFEN-P R (.7)/7.7 G254 ZFEN-P R (.7)/7.7 2 Diameter G254 ZFEN-P R (.7)/7.7 G259 ZFEN-P R (.7)/7.7 G2544 ZFEN-P R (.7)/7.7 4 Diameter G2545 ZFEN-P R (.7)/7.7 G2547 ZFEN-P R (.7)/7.7 G2549 ZFEN-P R (.7)/7.7 Diameter G254 ZFEN-P R (7.)/8.5 G2548 ZFEN-P R (7.)/8.5 G2550 ZFEN-P-2--7-R 7 22 (7.)/8.5 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. 9

10 Zenith Fenestrated AAA - Graft specifications Distal bifurcated body grafts ,, 20 2,, 20, ,, ,, 20, 24 2,, 20, 24 2,, 20, ,, 20 2,, 20, 24 2,, 20 Note: Black numbers on stents indicate stent lengths in millimeters. Red numbers indicate gap lengths in millimeters. Fabric gaps may vary. 2,, 20, 24 2,, 20, 24 2,, 20, 24 H&L-B One-Shot introduction system for distal bifurcated body grafts 20 Fr (.7 ) ID/7.7 OD 9 cm 40 cm 0

11 Zenith Fenestrated AAA - Component ordering information Order Number Reference Part Number Ipsilateral Leg Diameter Distal Leg Length Distal Body Length Introducer Sheath ID/OD Fr ()/ Ispilateral leg diameter Distal body length Distal leg length Distal Bifurcated Body Graft G255 ZFEN-D C (.7)/7.7 G2554 ZFEN-D C (.7)/7.7 G2500 ZFEN-D C (.7)/7.7 G250 ZFEN-D C (.7)/7.7 G25 ZFEN-D C (.7)/7.7 G255 ZFEN-D C (.7)/7.7 G259 ZFEN-D C (.7)/7.7 G257 ZFEN-D C (.7)/7.7 G2577 ZFEN-D C (.7)/7.7 G2580 ZFEN-D C (.7)/7.7 G2584 ZFEN-D C (.7)/7.7 G2588 ZFEN-D C (.7)/7.7 G2552 ZFEN-D C (.7)/7.7 G2555 ZFEN-D C (.7)/7.7 G2557 ZFEN-D C (.7)/7.7 G2559 ZFEN-D C (.7)/7.7 G252 ZFEN-D C (.7)/7.7 G25 ZFEN-D C (.7)/7.7 G2570 ZFEN-D C (.7)/7.7 G2574 ZFEN-D C (.7)/7.7 G2592 ZFEN-D--2-7-C (.7)/7.7 G258 ZFEN-D--2-9-C (.7)/7.7 G2585 ZFEN-D--2-0-C (.7)/7.7 G2589 ZFEN-D--2-2-C (.7)/7.7 G255 ZFEN-D C (.7)/7.7 G255 ZFEN-D C (.7)/7.7 G2558 ZFEN-D C (.7)/7.7 G250 ZFEN-D C (.7)/7.7 G25 ZFEN-D C (.7)/7.7 G257 ZFEN-D C (.7)/7.7 G257 ZFEN-D C (.7)/7.7 G2575 ZFEN-D C (.7)/7.7 G2578 ZFEN-D C (.7)/7.7 G2582 ZFEN-D C (.7)/7.7 G258 ZFEN-D C (.7)/7.7 G2590 ZFEN-D C (.7)/7.7 G254 ZFEN-D C (.7)/7.7 G258 ZFEN-D C (.7)/7.7 G2572 ZFEN-D C (.7)/7.7 G257 ZFEN-D C (.7)/7.7 G2579 ZFEN-D C (.7)/7.7 G258 ZFEN-D C (.7)/7.7 G2587 ZFEN-D C (.7)/7.7 G259 ZFEN-D C (.7)/7.7 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

12 Zenith Spiral-Z AAA iliac leg graft - Graft specifications Contralateral/ipsilateral iliac leg grafts Note: Black numbers on stents indicate stent lengths in millimeters. Z-Trak introduction system for iliac legs 9 grafts: Fr (4.7 ) ID/5.4 OD grafts: Fr (5. ) ID/ OD cm 7 cm 2

13 Zenith Spiral-Z AAA iliac leg graft - Component ordering information Order Number Reference Part Number Distal Iliac Leg Diameter Working Length of Iliac Leg Introducer Sheath ID/OD Fr ()/ 9 Diameter G5528 ZSLE-9-9-ZT 9 9 (4.7)/5.4 G5529 ZSLE-9-5-ZT 9 5 (4.7)/5.4 G55220 ZSLE-9-74-ZT 9 74 (4.7)/5.4 G5522 ZSLE-9-90-ZT 9 90 (4.7)/5.4 G55222 ZSLE-9-07-ZT 9 07 (4.7)/5.4 G5522 ZSLE-9-22-ZT 9 22 (4.7)/5.4 Diameter G55224 ZSLE--9-ZT 9 (4.7)/5.4 G55225 ZSLE--5-ZT 5 (4.7)/5.4 G5522 ZSLE--74-ZT 74 (4.7)/5.4 G55227 ZSLE--90-ZT 90 (4.7)/5.4 G55228 ZSLE--07-ZT 07 (4.7)/5.4 G55229 ZSLE--22-ZT 22 (4.7)/5.4 Distal iliac leg diameter Working length of iliac leg Diameter G5520 ZSLE--9-ZT 9 (4.7)/5.4 G552 ZSLE--5-ZT 5 (4.7)/5.4 G5522 ZSLE--74-ZT 74 (4.7)/5.4 G552 ZSLE--90-ZT 90 (4.7)/5.4 G5524 ZSLE--07-ZT 07 (4.7)/5.4 G5525 ZSLE--22-ZT 22 (4.7)/5.4 Diameter G552 ZSLE--9-ZT 9 (4.7)/5.4 G5527 ZSLE--5-ZT 5 (4.7)/5.4 G5528 ZSLE--74-ZT 74 (4.7)/5.4 G5529 ZSLE--90-ZT 90 (4.7)/ Diameter G55240 ZSLE-20-9-ZT 20 9 (5.)/ G5524 ZSLE-20-5-ZT 20 5 (5.)/ G55242 ZSLE ZT (5.)/ G5524 ZSLE ZT (5.)/ 24 Diameter G55244 ZSLE-24-9-ZT 24 9 (5.)/ G55245 ZSLE-24-5-ZT 24 5 (5.)/ G5524 ZSLE ZT (5.)/ G55247 ZSLE ZT (5.)/ Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

14 Zenith alignment stent - Component ordering information, 4, 5,, 7, 8 8, 2 Order Number Reference Part Number Diameter Length Minimum Introducer Sheath ID Fr Minimum Guiding Catheter OD Fr G4927 ZFS G49277 ZFS G49278 ZFS G49279 ZFS G49280 ZFS G4928 ZFS G49282 ZFS G4928 ZFS G49284 ZFS G49285 ZFS G4928 ZFS G49287 ZFS Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

15 5

16

17 Select case-specific EVAR accessories. ACCESSORIES FOR FENESTRATED ENDOVASCULAR PROCEDURES We have the accessories you need for your fenestrated EVAR cases, including access needles, dilators, introducers, wire guides, and a variety of catheters. Order Number Reference Part Number Description Quantity Access Needle G0487 SDN-9UT-7.0 Vascular Access Needle Balloon G5024 CODA Coda Balloon Catheter Catheters G795 HNBR P-NS-VANSCHIE Van Schie Beacon Tip Seeking Catheter G794 HNBR P-NS-VANSCHIE2 Van Schie Beacon Tip Seeking Catheter G792 HNBR P-NS-VANSCHIE Van Schie Beacon Tip Seeking Catheter G78 HNBR P-NS-VANSCHIE4 Van Schie Beacon Tip Seeking Catheter G79 HNBR P-NS-VANSCHIE5 Van Schie Beacon Tip Seeking Catheter G0844 HNBR P-NS-C Torcon NB Advantage Beacon Tip Catheter, C 5 G08442 HNBR P-NS-C2 Torcon NB Advantage Beacon Tip Catheter, C2 5 G08444 HNBR P-NS-RIM Torcon NB Advantage Beacon Tip Catheter, RIM 5 G0949 HNBR P-NS-KMP Torcon NB Advantage Beacon Tip Catheter, KMP 5 G0877 HNBR P-NS-SIM Torcon NB Advantage Beacon Tip Catheter, SIM 5 G0825 HNBR P-NS-SIM2 Torcon NB Advantage Beacon Tip Catheter, SIM2 5 G89 HNBR P-NS-VS Torcon NB Advantage Beacon Tip Angiographic Catheter 5 G2007 SCBR P-NS-VERT Slip-Cath Beacon Tip Catheter, VERT 5 G2008 SCBR P-NS-C2 Slip-Cath Beacon Tip Catheter, C2 5 G094 HNR P-0S-0 Beacon Tip Royal Flush Plus Straight Catheter 5 G27 HNR P-0S-0 Beacon Tip Royal Flush Plus Straight Catheter 5 G09059 HNR P-0S-PIG Beacon Tip Royal Flush Plus Pigtail Catheter 5 G2 NR P-0S-PIG-CSC-20 Aurous Beacon Tip Pigtail Sizing Catheter 5 G5254 CXI P-NS-0 CXI Support Catheter Dilator Sets G528 JCDS--EDS-HC Endovascular Dilator Set G5284 JCDS-8-EDS-HC Endovascular Dilator Set 2 G5285 JCDS-2022-EDS-HC Endovascular Dilator Set 2 G528 JCDS-242-EDS-HC Endovascular Dilator Set 2 Continued on page 8 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. MEDICAL

18 Accessories for Fenestrated Endovascular Procedures - Ordering information Continued from page Order Number Reference Part Number Description Quantity Introducers G078 RCF J Check-Flo Performer Introducer G52 KCFW RB-HFANL-HC Flexor Ansel Check-Flo Introducer with High-Flex Dilator G4904 KCFW RB-HFANL-HC Flexor Ansel Check-Flo Introducer with High-Flex Dilator G49045 KCFW RB-HFANL-HC Flexor Ansel Check-Flo Introducer with High-Flex Dilator G28999 XVCFW Extra-Large Check-Flo Performer Introducer G28 XVCFW Extra-Large Check-Flo Performer Introducer G289 XVCFW Extra-Large Check-Flo Performer Introducer Wire Guides G009 TSFB-5-5 Bentson Straight Fixed Core Wire Guide G00 TSFB-5-20 Bentson Straight Fixed Core Wire Guide G455 TSCMG LES Lunderquist Extra-Stiff Curved Exchange Support Wire Guide 5 G45208 TSCMG-5-20-LESDC Lunderquist Extra-Stiff Double Curved Exchange Support Wire Guide 5 G0758 RPC-5-80 Roadrunner PC Wire Guide, The Firm 5 G0905 RPC-5-20 Roadrunner PC Wire Guide, Exchange G025 THSCF ROSEN Rosen Heavy Duty Wire Guide G2020 THSCF AUS2 Amplatz Stiff Curved Exchange Wire Guide Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. 8

19

20 MEDICAL Customer Service EMEA: EDI Distributors: , Austria: , Belgium: , Denmark: , Finland: , France: , fr.orders@cookmedical.com Germany: , de.orders@cookmedical.com Hungary: , hu.orders@cookmedical.com Ireland: , ie.orders@cookmedical.com Italy: , it.orders@cookmedical.com Netherlands: , nl.orders@cookmedical.com Norway: , no.orders@cookmedical.com Spain: , es.orders@cookmedical.com Sweden: , se.orders@cookmedical.com Switzerland French: , fr.orders@cookmedical.com Switzerland Italian: , it.orders@cookmedical.com Switzerland German: , de.orders@cookmedical.com United Kingdom: , uk.orders@cookmedical.com Americas: EDI Phone: , , Fax: orders@cookmedical.com Australia: Phone: , , Fax: , cau.custserv@cookmedical.com COOK 20 AI-BUSM-FENTSP-EN-2002

Accepts Wire Guide Diameter inch. Stent Diameter mm

Accepts Wire Guide Diameter inch. Stent Diameter mm Order Number Reference Part Number Accepts Wire Guide inch Length Minimum ID inch Fr Formula 418 80 cm Over-the-Wire Delivery System G56605 FOR418-18-80-4-12.018 4 12.068 6.0/5.0 G56606 FOR418-18-80-4-16.018

More information

Physician s. Zenith. pocket reference guide ENDOVASCULAR GRAFTS. Indications for use. Component ordering information. Introduction system information

Physician s. Zenith. pocket reference guide ENDOVASCULAR GRAFTS. Indications for use. Component ordering information. Introduction system information Physician s pocket reference guide Indications for use Component ordering information Introduction system information Graft specifications Accessory products Zenith ENDOVASCULAR GRAFTS United States cookmedical.com

More information

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1 (19) United States US 20040073141A1 (12) Patent Application Publication (10) Pub. No.: US 2004/0073141 A1 Hartley et al. (43) Pub. Date: Apr. 15, 2004 (54) GUIDE WIRE (75) Inventors: David Ernest Hartley,

More information

Devices for Enteroscopes

Devices for Enteroscopes Single-Use Biopsy Forceps 16.1 Single-Use Injection Needles 16.1 Single-Use Cleaning Brushes 16.2 Single-Use Guide Wires & E.R.C.P. Catheters 16.2 Single-Use Sphincterotomes 16.3 Single-Use Stent Placement

More information

2013 Product Guide endoscopic accessories

2013 Product Guide endoscopic accessories 2013 Product Guide endoscopic accessories MEDICAL www.cookmedical.com Contents General Information... 7 Fusion Biliary System Control Fusion Wire Guide Locking Device.............................................................

More information

Wire Technology: How to Choose Based on Anatomy and Strategy

Wire Technology: How to Choose Based on Anatomy and Strategy Wire Technology: How to Choose Based on Anatomy and Strategy Craig M. Walker, MD, FACC, FACP Clinical Professor of Medicine Tulane University School of Medicine New Orleans, LA Clinical Professor of Medicine

More information

ERCP Papillotomes, balloons, guide wires and baskets.

ERCP Papillotomes, balloons, guide wires and baskets. Papillotomes, balloons, guide wires and baskets. REF Lumens Tip length mm Working length mm Cutting wire length mm Partly insulated cutting wire Papillotome DSP-30525-111111 3 5 2000 25 no DSP-30225-111111

More information

Leading the Way in Guide Wire Technology

Leading the Way in Guide Wire Technology 1/13 Leading the Way in Comprehensive portfolio of guide wires Advanced Technology Abbott Vascular Guide Wires / Indications: This HI-TORQUE Guide Wire is intended to facilitate the placement of balloon

More information

CROSS YOUR WAY SUPPORT CATHETERS GUIDEWIRES CROSSING CATHETERS RE-ENTRY DEVICES

CROSS YOUR WAY SUPPORT CATHETERS GUIDEWIRES CROSSING CATHETERS RE-ENTRY DEVICES CROSS YOUR WAY Medtronic offers a robust crossing portfolio toolkit to help you confidently navigate tortuous vasculature and cross complex lesions. No matter your preferred crossing method, Medtronic

More information

MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION CASE REPORTS

MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION CASE REPORTS MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION REPORTS TYPE II ENDOLEAK FROM THE INFERIOR MESENTERIC ARTERY Nuno V Dias MD, PhD Associate Professor Vascular Center Skåne University

More information

Fax Japan São Paulo (SP) Tokyo Minato-ku , Minami-Aoyama. St. Jude Medical Brasil Ltda.

Fax Japan São Paulo (SP) Tokyo Minato-ku , Minami-Aoyama. St. Jude Medical Brasil Ltda. Atrial Fibrillation Cardiac Rhythm Management Cardiovascular Neuromodulation Global Headquarters One St. Jude Medical Drive St. Paul, Minnesota 55117 USA +1 651 756 2000 +1 651 756 3301 Fax St. Jude Medical

More information

How to Penetrate the Proximal and Distal Fibrous Caps in Chronic Total Occlusion?

How to Penetrate the Proximal and Distal Fibrous Caps in Chronic Total Occlusion? April 27 th, 2006 Seoul, Korea How to Penetrate the Proximal and Distal Fibrous Caps in Chronic Total Occlusion? Masahiko Ochiai MD, FACC, FESC, FSCAI Division of Cardiology and Cardiovascular Surgery

More information

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Catalogue NE 0506 FIXTURING SYSTEM Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Modular Zero Point Fixturing System 9000 Changes in Seconds Constant zero point without realignment

More information

Prostar XL Percutaneous Vascular Surgical Device

Prostar XL Percutaneous Vascular Surgical Device Clinical leader for percutaneous large access site closure Close Access Sites Up to 24F Secure Closure Prostar XL Percutaneous Vascular Surgical Device Improved Outcomes 2009 Abbott Laboratories. All rights

More information

The Current CTO Toolbox

The Current CTO Toolbox The Current CTO Toolbox R. Michael Wyman, MD Director, Cardiac Catheterization Laboratory and Cardiovascular Interventional Research Torrance Memorial Medical Center Torrance, CA Disclosure Statement of

More information

Encapsulated Transformers 115V + 115V Primary, Low Profile

Encapsulated Transformers 115V + 115V Primary, Low Profile Features: Robust construction. Wide range of secondary voltages available. Single voltage and Dual voltage secondary combination. 2.0VA up to 52VA. CE marked. Designed and manufactured according to international

More information

Confidence Delivered.

Confidence Delivered. Confidence Delivered. INTERNATIONAL CAUTION: For distribution only in markets where CoreValve Evolut R has been approved. Non destiné au marché français. CoreValve Evolut R Transcatheter Aortic Valve Implantation

More information

R Evolut. Conf idence. Delivered. CoreValve

R Evolut. Conf idence. Delivered. CoreValve eferences: 1. sheath to Femoral Artery atio (SFA) greater than 1.05 predicted higher rates of VAC major vascular complications. Hayashida K, et al. Transfemoral aortic valve implantation. JACC Intv 2011;4(8):851-8.

More information

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Passive High Voltage Probes P5100 P5102 P5120 P6015A P5120. P5100 High Voltage Probe The P5100 is a low-input capacitance High Voltage Probe (2.5 kv) designed for higher frequency applications. The probe can be compensated to match plug-ins and oscilloscopes

More information

Medical Division Precision in diagnosis and therapy. Guide wires

Medical Division Precision in diagnosis and therapy. Guide wires Medical Division Precision in diagnosis and therapy. Guide wires Our guide wires are market leaders. Guide wires Guide wires, straight or with J-tip Size Outer Length Wire Core wire/ strip Core wire Distal

More information

Perclose ProGlide. Deployment Steps. Suture-Mediated Closure System Abbott. All rights reserved. ANZ /11

Perclose ProGlide. Deployment Steps. Suture-Mediated Closure System Abbott. All rights reserved. ANZ /11 Deployment Steps SUTURE TRIMMER Handle Needle Plunger Collar Lever Marker Lumen Body Foot QuickCut Link Foot (Deployed) Proximal Guide Guide Wire Exit Port Distal Guide Marker Port Sheath posterior side

More information

ASAHI Peripheral Guide Wire

ASAHI Peripheral Guide Wire ASAHI Peripheral Guide Wire AMK-DT256 Ver.1.01 / 12TS017 SYMBOLS Legal Manufacturer LOT Lot number Do not use if package is damaged REF Catalogue number Do not reuse STERILE EO Sterilized using ethylene

More information

SurePress L-4033 Digital Label Press VERSATILE PRINTING. CONSISTENT QUALITY.

SurePress L-4033 Digital Label Press VERSATILE PRINTING. CONSISTENT QUALITY. SurePress L-4033 Digital Label Press VERSATILE PRINTING. CONSISTENT QUALITY. GO DIGITAL AND BOOST YOUR BOTTOM LINE The SurePress L-4033 Inkjet Digital Label Press makes high-quality short-run printing

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

Process Control Calibration Made Easy with Agilent U1401A

Process Control Calibration Made Easy with Agilent U1401A Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration

More information

MEASURING THE PERFORMANCE OF Sub-2 µm PARTICLE COLUMNS: IMPACT OF EXTRA COLUMN BAND SPREADING AND LC OPERATING PRESSURE

MEASURING THE PERFORMANCE OF Sub-2 µm PARTICLE COLUMNS: IMPACT OF EXTRA COLUMN BAND SPREADING AND LC OPERATING PRESSURE MEASURING THE PERFORMANCE OF Sub-2 µm PARTICLE COLUMNS: IMPACT OF EXTRA COLUMN BAND SPREADING AND LC OPERATING PRESSURE Kenneth J. Fountain, Eric S. Grumbach, Uwe D. Neue, Diane M. Diehl introduction Since

More information

SpeedTip CCS 5.0, 7.0

SpeedTip CCS 5.0, 7.0 SURGICAL TECHNIQUE STEP BY STEP SpeedTip CCS 5.0, 7.0 Cannulated Compression Screws APTUS 2 SpeedTip CCS 5.0, 7.0 Cannulated Compression Screws Contents 3 Introduction Product Materials Indications Contraindications

More information

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet P5150 DC to 500 MHz 2500 V Peak, 1000 V RMS CAT II 50 X Floatable up to 600 V RMS CAT II or 300 V RMS CAT III For TPS2000 and THS3000

More information

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter. Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter Application Note Introduction Exceptional accuracy and repeatability DC bias function

More information

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer USB programmable output duty cycle symmetry control Precision output level controls permit signaling from 0 (Return to Zero) well in excess

More information

Interference Suppression Film capacitors

Interference Suppression Film capacitors MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm 10 and 15mm 22.5 and 27.5mm QUICK REFERENCE DATA Capacitance range (E6 series) * Capacitance tolerance Rated (AC) voltage 50 to 60 Hz Climatic category

More information

BZW06- Series DO-15. Mechanical Data. Page <1> 14/05/08 V1.1

BZW06- Series DO-15. Mechanical Data. Page <1> 14/05/08 V1.1 DO-15 Features: Plastic package. Exceeds environmental standards of MIL-STD-19500. 600W surge capability at 10 x 1000µs waveform, duty cycle: 0.01%. Excellent clamping capability. Low zener impedance.

More information

HRS2 Series PCB Relays

HRS2 Series PCB Relays Features: Low profile. Fully sealed. Standard and sensitive coil versions. DPCO contacts. Specifications: Coil Data: Nominal Voltage : 3V dc to 24V dc. Nominal Power Consumption : 150 to 360mW. Contact

More information

Welcome to the 7 th European Bifurcation Club October LISBON. Side Branch access session

Welcome to the 7 th European Bifurcation Club October LISBON. Side Branch access session Welcome to the 7 th European Bifurcation Club 14-15 October 2011 - LISBON Side Branch access session Role of dual-lumen catheter support Caress Sapporo Hokko Memorial Hospital Sapporo, Hokkaido Japan Yoichi

More information

Cardiac resynchronization therapy: overcoming anatomical challenges

Cardiac resynchronization therapy: overcoming anatomical challenges JBAC. 2018;31(4):146-155 Cardiac resynchronization therapy: overcoming anatomical challenges 1 MedStar Heart & Vascular Institute, Washington DC, USA 2 Instituto Cardiovascular Adventista, Buenos Aires,

More information

TIP120, 121, 122, 125, 126, 127 Darlington Transistors

TIP120, 121, 122, 125, 126, 127 Darlington Transistors Features: Designed for general-purpose amplifier and low speed switching applications. Collector-Emitter sustaining voltage-v CEO(sus) = 60V (Minimum) - TIP120, TIP125 80V (Minimum) - TIP121, TIP126 100V

More information

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview Keysight Technologies 85072A 10-GHz Split Cylinder Resonator Technical Overview 02 Keysight 85072A 10-GHz Split Cylinder Resonator - Technical Overview Part of the complete turn-key solution for the IPC

More information

Coatings. The Merit Hypotube. Coated Guide Wire Components. Coated Mandrels & Stylets. Coated Needles. Coating Services & Capabilities

Coatings. The Merit Hypotube. Coated Guide Wire Components. Coated Mandrels & Stylets. Coated Needles. Coating Services & Capabilities Coatings Merit Medical OEM offers PTFE and hydrophilic coatings, as well as further manufacturing and finishing services, for medical tubes and wires used in medical devices. The Merit Hypotube Center

More information

Ultraminiature Rocker&Lever Switches V ac or dc

Ultraminiature Rocker&Lever Switches V ac or dc Specifications: Contact Rating Mechanical Life Contact Resistance Minimum Insulation Resistance Dielectric Strength Operating Temperature Materials: Case and Bushing Switch Support Contacts/Terminals :

More information

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight B2901A/02A/11A/12A Precision Source/Measure Unit Demonstration Guide Introduction The Keysight Technologies, Inc. B2901A/02A/11A/12A

More information

Precision Vascular Robotics. Corindus Vascular Robotics (CVRS) January 2017

Precision Vascular Robotics. Corindus Vascular Robotics (CVRS) January 2017 Precision Vascular Robotics Corindus Vascular Robotics (CVRS) January 2017 1 Forward Looking Statements THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS (AS SUCH TERM IS DEFINED IN SECTION 27A OF

More information

Cardiac catheter control using actuator wire

Cardiac catheter control using actuator wire University of Iowa Iowa Research Online Theses and Dissertations Summer 2017 Cardiac catheter control using actuator wire Adam Thomas Snyder University of Iowa Copyright 2017 Adam Thomas Snyder This thesis

More information

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output LENORD +BAUER... automates motion. Technical information Version 03.3 General The measuring unit comprises a sensor and

More information

2-channel speed sensor GEL 247 Compact sensor for harsh applications

2-channel speed sensor GEL 247 Compact sensor for harsh applications 2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation

More information

20X Low Capacitance Probe P6158 Datasheet

20X Low Capacitance Probe P6158 Datasheet 20X Low Capacitance Probe P6158 Datasheet Circuit board impedance testing (TDR) High-speed sampling systems P6158 DC to 3 GHz The P6158 is a 3 GHz, 20X, low-capacitance probe. The P6158 is ideal for high-speed

More information

Agilent NFA Noise Figure Analyzer

Agilent NFA Noise Figure Analyzer Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110

More information

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth

More information

Guidewires for the CTO Interventionalist. William L. Lombardi MD FACC FSCAI Peacehealth St. Joseph Medical Center Bellingham WA

Guidewires for the CTO Interventionalist. William L. Lombardi MD FACC FSCAI Peacehealth St. Joseph Medical Center Bellingham WA Guidewires for the CTO Interventionalist William L. Lombardi MD FACC FSCAI Peacehealth St. Joseph Medical Center Bellingham WA Guide Wire Components 1. Core Material 2. Core Diameter 3. Core Taper 4. Tip

More information

Making a healthier world

Making a healthier world Medical Components With 200 years of expertise in platinum group metals, Johnson Matthey offers medical device manufacturers the security of supply to source, manage, fabricate, and recycle materials for

More information

User Guide.

User Guide. User Guide www.dymo.com D I K M L H G C F A B E J N A Tape cassette door H Character selection window B Tape rollers I Cutting handle C Tape advance knob J Embossing adjustment screw D Start line K Cable

More information

Differential Probes P6248 P6247 P6246 Datasheet

Differential Probes P6248 P6247 P6246 Datasheet Differential Probes P6248 P6247 P6246 Datasheet P6247 key performance specifications 1.0 GHz bandwidth (guaranteed) P6246 key performance specifications 400 MHz bandwidth (guaranteed) Key features Low

More information

New WMT Grooving Geometry PH Geometry

New WMT Grooving Geometry PH Geometry Page - - New WMT Geometry PH Geometry WIDIA has added the top-selling chipmaker geometry to the WMT platform - the PH geometry. Previously under the Manchester brand, the chipmaker geometry is a high performance

More information

AC Current Probes CT1 CT2 CT6 Data Sheet

AC Current Probes CT1 CT2 CT6 Data Sheet AC Current Probes CT1 CT2 CT6 Data Sheet Features & Benefits High Bandwidth Ultra-low Inductance Very Small Form Factor Characterize Current Waveforms up to

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

ACCURATE PRINTING MACHINES.

ACCURATE PRINTING MACHINES. ACCURATE PRINTING MACHINES www.pbt-works.com ABOUT PBT WORKS COMPANY PBT Works s.r.o. is the outstanding producer of SMT screen and stencil printing machines. Company maintains firm position within manual

More information

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz Configuration Guide Ordering Guide The following steps will guide you through configuring your 4294A. Standard Furnished Item CD-ROM Manual

More information

Keysight TC GHz Frequency Doubler

Keysight TC GHz Frequency Doubler Keysight TC221 50 GHz Frequency Doubler 1GC1-8038 Data Sheet Features Conversion Efficiency: 12 db Typical 1/2 and 3/2 spurs: 15 dbc Typical Broad Bandwidth, 20 50 GHz Output Frequency Introduction The

More information

LPR Series PCB Snap-In Large Capacitors

LPR Series PCB Snap-In Large Capacitors Features: LPR series large size capacitors with the specially designed self-standing" terminals can be directly soldered to printed circuit boards without holders. Easy fixing to PCBs without need for

More information

Speed and position sensor MiniCoder GEL 2442

Speed and position sensor MiniCoder GEL 2442 Speed and position sensor MiniCoder GEL 2442 contactless, high-resolution, high speed Technical information version 01.09 Functional description Measurement of speed and position by proximity sensing of

More information

MBR10xCT Series TO-220AB

MBR10xCT Series TO-220AB 10x Series Features: Plastic material. Metal silicon junction, majority carrier conduction. Low power loss, high efficiency. High current capability, low forward voltage drop. High surge capability. For

More information

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS LumiCoil Platinum Introducing the LumiCoil Platinum Features of LumiCoil Platinum s Expanding Innovation in EUS Ordering Information and Additional Resources LumiCoil Platinum Introducing the LumiCoil

More information

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software Introduction For undergraduate students in colleges and universities, frequency response testing

More information

Horizon. Your innovative partner in medicine technology.

Horizon. Your innovative partner in medicine technology. Horizon Valve Channel - Minimally Invasive Valve Surgery Original, Advanced, The Next Generation, Accessories, Sterilisation Container Your innovative partner in medicine technology. micvision.indd 1 08.10.2009

More information

Hot rolled square steel bars for general purposes Dimensions and tolerances on shape and dimensions

Hot rolled square steel bars for general purposes Dimensions and tolerances on shape and dimensions BRITISH STANDARD BS EN 10059:2003 Hot rolled square steel bars for general purposes Dimensions and tolerances on shape and dimensions The European Standard EN 10059:2003 has the status of a British Standard

More information

Image guidance reinvented. Foresight. Intracardiac Echo System

Image guidance reinvented. Foresight. Intracardiac Echo System Image guidance reinvented Foresight Intracardiac Echo System 2 Foresight ICE System Technical Specifications Foresight ICE System ICE-SYS-10F-USA The Foresight ICE System is indicated for intracardiac

More information

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide LabraLock P for Labrum Repair, Part of the OPUS LabraFix System A revolutionary new system specifically designed for labrum repair surgery System Includes: SpeedStitch Suturing Device LabraLock P Implant

More information

AEE. Canada. Australia

AEE. Canada. Australia DMARCA DE CONFORMIDA CORDS & ELECTRICAL UNIVERSAL POWER JUMPER CORD INTERNATIONAL AGENCIES APPROVED 302 POWER JUMPER CORD APPLICATIONS: To Connect Accessories and Peripherals to Computers and Electronic

More information

Passive Voltage Probes

Passive Voltage Probes Passive Voltage Probes TPP1000 TPP0500 TPP0502 Datasheet Connectivity Integrated Oscilloscope and Probe Measurement System provides Intelligent Communication that Automatically Scales and Adjusts Units

More information

Process-Controller HPP-25

Process-Controller HPP-25 Process-Controller HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software... joining is our business Process-Controller HPP-25 Riveting process

More information

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges W : iniature Photoelectric Switch Series with Large Scanning Ranges Photoelectric proximity switch with adjustable scanning distance and background suppression (BGS): Scanning distance = adjustable up

More information

THE 12 COUNTRIES IN OUR SAMPLE

THE 12 COUNTRIES IN OUR SAMPLE THE 12 COUNTRIES IN OUR SAMPLE We modeled the economic impact of artificial intelligence (AI) in 12 developed countries that currently make up 50 percent of global gross domestic product (GDP). Austria

More information

Solutions for Solar Cell and Module Testing

Solutions for Solar Cell and Module Testing Solutions for Solar Cell and Module Testing Agilent 663XB Power Supplies Connected in Anti-Series to Achieve Four-Quadrant Operation for Solar Cell and Module Testing Application Note Overview To fully

More information

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,

More information

AC Line Rated Disc Capacitors Class X1, 400 VAC/Class Y1, 500 VAC

AC Line Rated Disc Capacitors Class X1, 400 VAC/Class Y1, 500 VAC 4L Series D max.5" max (3.).5" min (3) Tinned Copper Leads AC Line Rated Disc Capacitors Class X, VAC/Class Y, 5 VAC LO =.58" (4.) typ. LS LO T max FEATURES Worldwide Safety Agency Recognition Underwriters

More information

tevdek ii the specialist green, polyester, braided suture material With special ptfe coating indications needle OVeRVieW ROunD bodied needles

tevdek ii the specialist green, polyester, braided suture material With special ptfe coating indications needle OVeRVieW ROunD bodied needles ARROW regional Suture anaesthesia material Nullan utpat, vulputpatie for cardiovascular ero dion surgery ulputat 2 Suture material for cardiovascular surgery Under Teleflex Medical s Deknatel brand name,

More information

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008 EM Insights Series Episode #1: QFN Package Agilent EEsof EDA September 2008 Application Overview Typical situation IC design is not finished until it is packaged. It is now very important for IC designers

More information

Through-beam ring sensors

Through-beam ring sensors Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable

More information

Arthroscopic Protector Meniscus Suturing Surgical Techniques

Arthroscopic Protector Meniscus Suturing Surgical Techniques Arthroscopic Protector Meniscus Suturing Surgical Techniques Protector Meniscus Suturing Protector Meniscus Suturing Technique I For the relatively rare meniscus tears located sufficiently anterior, to

More information

Reaming Technical Guide INCH

Reaming Technical Guide INCH Reaming Technical Guide INCH The Anatomy of a Reamer Use this diagram when describing features of a Solid Carbide Reamer. Diameter (D1) Shank Diameter (D) Tip Length (L1) Shank Length (LS) Max Reaming

More information

2N6668 Darlington Power Transistor

2N6668 Darlington Power Transistor Plastic Medium-Power Silicon Transistors are designed for general-purpose amplifier and low speed switching applications. Features: Collector-Emitter Sustaining Voltage V CEO(sus) = 80V (Minimum). Collector-Emitter

More information

MANUAL FOR DIRECT PRINTING

MANUAL FOR DIRECT PRINTING DIGITAL CAMERA MANUAL FOR DIRECT PRINTING Manual outlining new features added to the camera with firmware upgrade. This manual contains guidelines for using Olympus Stylus 300/400 DIGITAL (µ [mju:] 300/400

More information

MJ11032, Darlington Power Transistors

MJ11032, Darlington Power Transistors Complementary Silicon Power Darlington Transistors are designed for use as output devices in complementary general purpose amplifier applications. Features: High Gain Darlington performance. High : h FE

More information

International Standard

International Standard International Standard 4757 Cross recesses for screws Empreintes cnrciformes pour v First edition - 983-Wl UDC 62.882.25.6 f Ref. No. IS0 4757-983 (E) Descriptors : fasteners, screws, cruciform recessed

More information

No-Clean Flux Lead Free Tin/Silver/Copper Alloy

No-Clean Flux Lead Free Tin/Silver/Copper Alloy Features: Halide free version-typ 400. Mild odour. Fast soldering-range of activities to suit all applications. Clear residues. Good spread on copper, brass and nickel. Heat stable-low spitting. Multicomp

More information

MiniCoder GEL 2444T Sensor with square-wave signals and internal interpolation

MiniCoder GEL 2444T Sensor with square-wave signals and internal interpolation MiniCoder GEL 2444T Sensor with square-wave signals and internal interpolation Technical Information Version 2. General The measuring unit consists of a sensor and a precision target wheel for mounting

More information

Reflex Hybrid System Overview

Reflex Hybrid System Overview Spine Reflex Hybrid System Overview Anterior Cervical Plating System Introduction The Reflex Hybrid ACP System offers a low-profile anterior cervical plate along with a selection of bone screw types to

More information

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview Agilent N8480 Series Thermocouple Power Sensors Technical Overview Introduction The new N8480 Series power sensors replace and surpass the legacy 8480 Series power sensors (excluding the D-model power

More information

Agilent 8761A/B Microwave Switches

Agilent 8761A/B Microwave Switches Agilent 8761A/B Microwave Switches Technical Overview Product Description The Agilent Technologies 8761A and 8761B are single-pole, double-throw coaxial switches with excellent electrical and mechanical

More information

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification 2 Requires

More information

BU426A Power Transistor

BU426A Power Transistor High Voltage Switching BU426A type is a fast switching high voltage transistor, more specially intended for operating in colour TV supply systems. Features: Collector-Emitter sustaining voltage - V CEO(sus)

More information

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet 02 Keysight N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

More information

BUV48A Power Transistor

BUV48A Power Transistor High Voltage Switching Switchmode Series NPN s are designed for use in high-voltage, highspeed, power switching regulators, converters, inverters, motor control system application. Features: Collector-Emitter

More information

Unofficial Ottawa Fellowship Guide to Endovascular interventions, Anton Sharapov, MD, FRCS, Vascular Surgeon Updated October 26, 2014

Unofficial Ottawa Fellowship Guide to Endovascular interventions, Anton Sharapov, MD, FRCS, Vascular Surgeon Updated October 26, 2014 Ottawa U Guide to Endovascular Interventions, A. Sharapov, MD Unofficial Ottawa Fellowship Guide to Endovascular interventions, Anton Sharapov, MD, FRCS, Vascular Surgeon Updated October 26, 2014 What

More information

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Making Field Effect Transistor Characterization Using SMU Keysight Technologies Making Field Effect Transistor Characterization Using SMU B2900A Precision Source/Measure Unit Demo Guide Introduction The Keysight s B2900A Series Precision Source/Measure Unit (SMU)

More information

Agilent InfiniiMax III probing system

Agilent InfiniiMax III probing system Agilent InfiniiMax III probing system Data Sheet World s highest speed and highest performing probe system Full 30 GHz bandwidth to the probe tip Industry s lowest probe and scope system noise Industry

More information

Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics. Preliminary Data Sheet

Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics. Preliminary Data Sheet Keysight Technologies E1834E/G/J/M/Z Mounted Beam Delivery Optics Preliminary Data Sheet The Keysight Technologies, Inc. E1834 family of beam delivery optics uses high performance mounts to meet the pointing

More information

OROTAN N-4045 Pigment Dispersant

OROTAN N-4045 Pigment Dispersant Technical Data Sheet OROTAN N-4045 Pigment Dispersant For Latex Paint Formulations Regional Product Availability Description Characteristics of the Product EMEA OROTAN N-4045 Pigment Dispersant is a polycarboxylic

More information

2N6054/2N6056 Darlington Transistors

2N6054/2N6056 Darlington Transistors Features: General-purpose power amplifier and low frequency switching applications. Low Collector-Emitter Saturation Voltage - V CE(SAT) = 2.0V (Maximum) at I C = 4.0A = 3.0V (Maximum) at I C = 8.0A Monolithic

More information

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO 9431:1999

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO 9431:1999 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN ISO 9431 July 1999 ICS 01.100.00 English version Construction drawings - Spaces for drawing and for text, and title blocks on drawing sheets (ISO

More information

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide Keysight Technologies NFA Noise Figure Analyzer Configuration Guide Noise Figure Analyzer Overview Over 50 years of noise figure leadership Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz

More information