1 ONE TOUCH PERFECT TEMPERATURE Introducing the digital shower range with wireless control from Mira Showers.

2 THE FUTURE OF SHOWERS. TODAY. Experience a new way of showering with Mira. With its stylish wireless controllers and ground-breaking digital mixer technology, it s the future of showering. Mira digital showers are engineered to provide precise control that gets the temperature right first time, every time. You ll have a consistent temperature for your shower even if someone is showering or using taps elsewhere in your home. Mira digital showers feature a digital mixer and a choice of four wireless controllers that replace conventional taps. The Mira 360m showerhead and rail completes the experience. With features such as warm-up mode, digital display and the option of a second controller, Mira delivers thoughtful technology that is as individual as you are. 2

3 3

4 WHY DIGITAL? Mira showers offer the latest advances in shower technology, with one-touch, pre-programmable features that deliver the perfect temperature every time you shower. thermostatic Precise Control Separate temperature and flow controls to fine tune your perfect shower. Warm-up Feature No need to step in until the temperature is just right thanks to the warm-up function. eco setting Eco Mode Conserve water and make a saving with the Eco setting. Digital Display The digital clock display ensures that you ll never be late again. Flipstream technology Complete your shower with a Mira 360m showerhead 1 flip action, 4 unique sprays.

5 5

6 MIRA PLATINUM Digital Shower Mixer PRODUCT OPTIONS Mira Platinum digital mixer & wireless controller with showerhead & rail Mira Platinum digital mixer & wireless controller only ACCESSORY Mira Platinum wireless controller accessory (can be used as a second controller outside the shower) Mira Platinum Wireless Controller (Rotate to adjust flow rate) Mira Platinum with Mira 360m showerhead and rail MIRA VISION Digital Shower Mixer PRODUCT OPTIONS Mira Vision digital mixer & wireless controller with showerhead & rail Mira Vision digital mixer & wireless controller only ACCESSORY Mira Vision wireless controller accessory (can be used as a second controller outside the shower) Mira Vision Wireless Controller Mira Vision with Mira 360m showerhead and rail 6

7 MIRA VIER Digital Shower Mixer PRODUCT OPTIONS Mira Vier digital mixer & wireless controller with showerhead & rail Mira Vier digital mixer & wireless controller only ACCESSORY Mira Vier wireless controller accessory (can be used as a second controller outside the shower) Mira Vier Wireless Controller Mira Vier with Mira 360m showerhead and rail MIRA PIXEL Digital Shower Mixer PRODUCT OPTIONS Mira Pixel digital mixer & wireless controller with showerhead & rail Mira Pixel digital mixer & wireless controller only ACCESSORY Mira Pixel wireless controller accessory (can be used as a second controller outside the shower) Mira Pixel Wireless Controller Mira Pixel with Mira 360m showerhead and rail 7

8 MIRA 360M SHOWERHEAD AND RAIL Complete your shower with a Mira 360m showerhead 1 flip action 4 unique sprays Turn the shower on with a second controller before you step in... Mira 360m showerhead and rail is available as part of the complete Mira digital shower and is not sold separately. 8

9 DIGITAL IS EASY! So how do digital showers with wireless control work? Installation schematic To mains power supply Digital mixer unit Valve Outlet Cold Water Inlet Hot Water Inlet Wireless Controller Max 10 metres (free air) between the wireless controller and the digital mixer unit There are three parts that make up our digital showers with wireless control: the digital mixer unit (1), the wireless shower controller (2) and the showerhead and rail (3). The digital mixer is the brains of the shower, mixing hot and cold water supplies for the perfect showering temperature and flow of water to the shower. Unlike a typical shower mixer, the digital mixer unit can be mounted hidden from view and remote from the shower recess, for example in a cupboard, vanity unit or ceiling cavity. The wireless controller replaces conventional taps within the shower recess, enabling users to adjust both temperature and flow to suit their own comfort with the push of a button. With a choice of four styles, the wireless controllers offer a sleek, minimalist look to any bathroom and a second controller can be placed anywhere within 10 metres of the digital mixer unit. Each wireless controller is paired to the digital mixer unit and they communicate with each other to signal the temperature and flow rate required. DIGITAL MIXER UNIT WIRELESS CONTROLLER (Additional wireless controllers available) SHOWERHEAD & RAIL (Can be supplied with or without the Mira showerhead & rail) 9

10 EASY TO FIT Using Mira Vision, we show you how easy it is for a licensed plumber to fit any Mira digital shower mixer with wireless control. Digital Mixer Unit To Mains Power Supply Hot inlet Inlet isolators Cold inlet Isolator Outlet Metal pipe must be earth bonded Mira Vision Wireless Controller and 360m Showerhead & Rail What you need to know about installing Mira digital Types of hot water systems: Mira digital mixers work with mains pressure systems such as hot water storage, gas continuous flow and heat pumps. Low pressure and gravity fed systems are not suitable. Power supply: 240VAC mains power is required for the digital mixer unit (black box). A 30mA residual current device (RCD) must be included in the electrical circuit. Wireless controller: The wireless controller is used instead of taps in your shower. It is installed in the shower recess and no cables are required. The wireless controller enables you to turn the shower on and off, as well as adjust the temperature and flow rate. It uses 3 x AA batteries and communicates wirelessly with the digital mixer unit. Digital mixer unit (black box): The digital mixer unit must be installed within 10 metres of the wireless controller. It can be installed in a ceiling cavity, a vanity or a cupboard and needs to be accessible for maintenance. The outlet pipework distance from the unit to the shower should be less than 5m. Water Connections: The digital mixer unit is supplied with brass hot and cold inlet and outlet tails, equivalent in diameter to 15mm copper pipe. This allows a licensed plumber to use their preferred plumbing fittings to connect the inlets to the hot and cold water and the outlet to the shower. The brass tails can be temporarily removed from the digital mixer unit so that plumbing fittings can be soldered to the tails, without damaging the unit. Pressures: Hot and cold inlet pressures should be nominally equal. Max. static pressure: 1000kPa; Max. working pressure: 500kPa; Min. working pressure: 50kPa Safe Temperatures: Mira digital shower mixers have WaterMark certification to AS as a thermostatic mixing valve. They are an approved temperature control device for limiting outlet water temperatures to safe levels under AS/NZS

11 F8624 FOR HIGH PRESSURE / COMBINATION FOR HIGH BOILER PRESSURE / COMBINATION BOILER POWER: 230V ~ 20W POWER: 230V ~ 20W PROTECTION: IP24 PROTECTION: IP24 MIN. SUPPLY PRESSURE: 50 kpa (0.5 MIN. bar) SUPPLY PRESSURE: 50 kpa (0.5 bar) MAX. WORKING PRESSURE: 500 kpa MAX. (5 bar) WORKING PRESSURE: 500 kpa (5 bar) MAX. STATIC PRESSURE: 1000 kpa (10 MAX. bar) STATIC (WRAS) PRESSURE: 1000 kpa (10 bar) (WRAS) MAX. SUPPLY WATER TEMP: 65 C MAX. SUPPLY WATER TEMP: 65 C MOUNTING POSITION OR MOUNTING POSITION OR VERTICAL HORIZONTAL VERTICAL HORIZONTAL KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) F8624 KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) Installing a Mira Digital Mixer Shower Step 1 Step 2 Choose a convenient place to fit the digital mixer unit (black box), ensuring it is accessible for maintenance. This could be in the ceiling, a vanity or a cupboard. Hot and cold water needs to be connected to the digital mixer valve inlets. Decide where you want to put the showerhead and rail. Then screw the slide bar rail to the wall using the 4 screws provided. Step 3 Step 4 Decide where to locate the wireless controller in the shower recess (the digital mixer valve must be located within 10 metres of the wireless controller). It is simply attached to the wall using the 2 screws provided. After the pipework has been connected to the digital mixer unit, simply screw the shower hose and handset to the wall outlet. Mira digital mixer dimension drawings 68 mm 240 mm240 mm 35 mm 35 mm ISOLATE MAINS ELECTRICITY ISOLATE BEFORE MAINS ELECTRICITY BEFORE REMOVING COVER! REMOVING COVER! PLATINUM DIGITAL MIXER PLATINUM DIGITAL MIXER PART No N85A MANUFACTURED DATE: PART No N85A MANUFACTURED DATE: 180 mm mm mm 217 mm HOT COLD HOT COLD 36 mm 47 mm47 mm to centre of inlets/outlets 180 mm180 mm For full installation information please refer to the Product Installation guide on our website 11

12 When tested at 35kPa in accordance with standard AS/NZS 6400 When tested at 150, 250 & 350kPa in accordance with standard AS/NZS 6400 More information Visit for stockists, product details and more information about our range or contact us on Mira digital shower products are distributed in Australia by Thornthwaite Technologies Pty Ltd. Warranty Digital Mixer & Wireless Controller 2 Year Standard Warranty *. Mira 360m Showerhead 1 Year Standard Warranty. * Register your Digital Mixer & Wireless Controller for additional 3 years warranty subject to terms & conditions available from our website. Approvals Mira Digital Shower Mixer WaterMark certification to Australian Standard AS C Tick Electromagnetic compatibility (EMC) Conformance for electrical safety EN & EN AS Lic 1892 SAI Global Mira 360m Showerhead WELS Registered 3 stars, 8 L/min WaterMark certification to Australian Standard AS/NZS 3662 The more stars the more water efficient WATER RATING WHEN TESTED AT LOW PRESSURE A joint government and industry program Licence No: 0089 Water Consumption The more stars the more water efficient A joint government and industry program Licence No: 0089 Water Consumption AS/NZS 3662 Lic SAI Global litres per minute For more information and to compare products, refer to: litres per minute For more information and to compare products, refer to: Follow MiraShowersAU Scan the QR code to learn more. Thornthwaite Technologies 79 Victoria Avenue, Chatswood NSW 2067 Australia Phone: info@mirashowers.com.au MIRAAUBR201406

DIGITAL IS EASY. Introducing the digital shower range with wireless control from Mira Showers.

DIGITAL IS EASY. Introducing the digital shower range with wireless control from Mira Showers. DIGITAL IS EASY Introducing the digital shower range with wireless control from Mira Showers. www.mirashowers.co.uk/expert Digital is Easy! So how do digital showers with wireless control work? There are

More information

Chisel TAPWARE SHOWERS ACCESSORIES

Chisel TAPWARE SHOWERS ACCESSORIES Chisel TAPWARE SHOWERS ACCESSORIES Class Leading Design The designers at Faucet Strommen used round, soft square & rectangle elements to form the beautiful Chisel tapware range. Perfect proportions and

More information

caroma marc newson wall basin mixer

caroma marc newson wall basin mixer caroma marc newson wall basin mixer water efficient tapware (nominal flow rate = 5 L/min) PLUMBERS INSTALLATION INSTRUCTIONS IS1213A(07/12) Important Information Brazed connections should NOT be made directly

More information

BLUETOOTH MINI A5 (2018):Layout 1 27/03/ :57 Page 2 SDS236T. Instant Match Transformer. Quick Connect Guide WITH

BLUETOOTH MINI A5 (2018):Layout 1 27/03/ :57 Page 2 SDS236T. Instant Match Transformer. Quick Connect Guide WITH BLUETOOTH MINI A5 (2018):Layout 1 27/03/2018 14:57 Page 2 SDS236T Instant Match Transformer Quick Connect Guide WITH BLUETOOTH MINI A5 (2018):Layout 1 27/03/2018 14:57 Page 3 Plumbing of the Waste Pipe

More information

Flash Rough-In Valves

Flash Rough-In Valves Flash Rough-In Valves American Standard I Flash Rough-In Valves I 1 Take Your Time Back At American Standard, we are constantly thinking about how our products can improve the way you work every day. Every

More information

SDS131T. Instant Match Transformer. Quick Connect Guide WITH

SDS131T. Instant Match Transformer. Quick Connect Guide WITH SDS131T Instant Match Transformer Quick Connect Guide WITH mbing of the Waste Pipe Wireless System Registration Important Information WARNING Please read the following information before setting up a wireless

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES STYLE No. DSXS20 with 8 Shower Head and Metal Cross Handles STYLE No. DSXS2C System with Metal Cross Handles STYLE No. DSXS30 with 8 Shower Head, Metal Lever and Cross Handle STYLE No. DSXS3C System with

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS NOT INCLUDED NOT INCLUDED MODEL: LUGARNO HAND SHOWER SET (RH-9) Restoration Hardware Hand Shower / Slide Bar Specification Diagram SHOWN WITH SHOWER SET RH-90 (NOT INCLUDED) All

More information

The Brodware Difference 03. Neu England 06 Chelsea 12 Olde English 14. Product Table 16 Technical 18

The Brodware Difference 03. Neu England 06 Chelsea 12 Olde English 14. Product Table 16 Technical 18 Neu England The Brodware Difference 03 Neu England 06 Chelsea 12 Olde English 14 Product Table 16 Technical 18 02 Australian Manufacturer. Brodware Industries is an independent family owned business trading

More information

caroma marc newson shower mixer

caroma marc newson shower mixer caroma marc newson shower mixer PLUMBERS INSTALLATION INSTRUCTIONS IS1215A(07/12) Important Information Brazed connections should NOT be made directly onto the mixer, as excessive heat will cause permanent

More information

Showering Perfection. Mira Showers

Showering Perfection. Mira Showers Showering Perfection Mira Showers Making the everyday, extraordinary. Water. So often taken for granted and yet it plays such a profound role in all our lives. We believe that it is our purpose to make

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FURNITURE VALENCIA Vanity Floor Standing Models Contemporary design and quality construction, providing affordable storage for bathrooms of any size or style. It s the details

More information

CALLAS THERMOSTATIC SHOWER SET

CALLAS THERMOSTATIC SHOWER SET SKU(s): 925945 CALLAS THERMOSTATIC SHOWER SET BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for

More information

ONASSIS SHOWER SET INSTALLATION

ONASSIS SHOWER SET INSTALLATION SKU(s): 925939 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for any damage to the plumbing, floor,

More information

LATTIMORE SHOWER SET INSTALLATION

LATTIMORE SHOWER SET INSTALLATION SKU(s): 931419 LATTIMORE SHOWER SET INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Bradley Barrier-Free HN-300 In-Wall Shower Table of Contents Pre-Installation Information................2 Warranty...............................2 Components

More information

LIFT. Please give your shopfitters not only this information sheet but also the floor plan showing the exact position of the unit.

LIFT. Please give your shopfitters not only this information sheet but also the floor plan showing the exact position of the unit. Installation instructions LIFT Backwash unit Important notes for the salon owner This technical information has been produced for your shopfitters. Remember to give them good advance warning so that your

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

Installation Instructions Student 101 Fume Cupboard

Installation Instructions Student 101 Fume Cupboard Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing

More information

EXIRA SHOWER SET INSTALLATION

EXIRA SHOWER SET INSTALLATION SKU(s): 925470 EXIRA SHOWER SET INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for

More information

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS 2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS Contents Section Brief Description... 1 Where and why it is used... 1.1 Induced Measureable Parameters... 1.2 Hardware

More information

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact measurements of temperatures up to 400 C. They consist

More information

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force 4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14 Evaporator E2 Series Medium & Low Temperature Models Innovative Refrigeration Solutions Issue: 05/14 APPLICATION BENEFITS / FEATURES HIGH EFFICIENCY HEAT EXCHANGER COIL Capacity steps in the range are

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Special Care. Care products 1:12:1 1:12:2. Rails and hinged supports. Icon key. Special Care. Blue Book Armitage Shanks. Residential.

Special Care. Care products 1:12:1 1:12:2. Rails and hinged supports. Icon key. Special Care. Blue Book Armitage Shanks. Residential. Blue Book Armitage Shanks Care products Rails and hinged supports 1:12:1 1:12:2 Icon key Residential Public Places Water Savings Hospitals & Healthcare Disabled access Doc M Compliant Education Spacesaving

More information

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke s 4 509 ACVATIX Electromotoric actuators for valves SAX..P with a 20 mm stroke SAX31P.. Operating voltage AC 230 V, 3-position control signal SAX61P.. Operating voltage AC/DC 24 V, control signal DC 0

More information

CW-1401 (WL1212) CB-1401 (BL1212)

CW-1401 (WL1212) CB-1401 (BL1212) INSTALLATION INSTRUCTIONS C-00 (LB) CROSS HANDLE WALL-MOUNTED -HOLE BASIN MIXER TRIM ONLY, TO SUIT R-0 ROUGH CW-0 (WL) WHITE LEVER WALL-MOUNTED -HOLE BASIN MIXER TRIM ONLY, TO SUIT R-0 ROUGH CB-0 (BL)

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011 NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

COFFEE LABORATORY WHITE STONE VA TEL

COFFEE LABORATORY WHITE STONE VA TEL 1. Technical specifications 4. Operating instructions: Octagon 200 Copyright 2015 by Endecotts Ltd. 21 1. Setting up Technical specifications SIEVE SHAKER MODEL: Octagon 200 General Information The sieve

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

LEVEL PLUMBING TASK MANUAL

LEVEL PLUMBING TASK MANUAL VRQ LEVEL 2 6129 PLUMBING TASK MANUAL City & Guilds Level 2 Certificate in Basic Plumbing Studies Task Manual Level 2 Units Candidate detail sheet You should be provided with this manual at the outset

More information

7. Operating instructions: EFL 300

7. Operating instructions: EFL 300 7. Operating instructions: EFL 300 Copyright 2015 by Endecotts Ltd. 59 1. Setting up Technical specifications SIEVE SHAKER MODEL: EFL 300 General Information The new EFL 300 combines the best features

More information

Electromotoric actuators

Electromotoric actuators s 4 540 ACVATIX Electromotoric actuators for Combi valves VPI45.., DN40/50 SQD65 operating voltage AC 230 V, 3-position control signal operating voltage AC 24 V, 3-position control signal SQD65 operating

More information

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum. We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate

More information

Site plan. Water tapping. Water Main. Property boundary. Guru Gully Road. Portico. Scale example:

Site plan. Water tapping. Water Main. Property boundary. Guru Gully Road. Portico. Scale example: Site plan Side A Water tapping 80 mm Srage water heaters Guru Gully Road Water Main Property boundary 100 mm Portico Instructions 1. Cut and fold along lines. 2. Slide side A and Side B gether. 3. Ensure

More information

The CM Range. Clearly different

The CM Range. Clearly different The CM Range. Clearly different Effortless efficiency Our CM900 range of programmable thermostats offers maximum energy efficiency with minimum fuss. They all feature our unique Line of Text (LoT ) display,

More information

CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Installation guide. MODERN LEVER BATHROOM Basin Set

Installation guide. MODERN LEVER BATHROOM Basin Set Installation guide MODERN LEVER BATHROOM Basin Set What makes us different? EXTRA Features Convert any existing taps to lever style Three quarter turn lever for finer flow and temperature control Smooth-glide

More information

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment Locator Accessories DATA SHEETS Accessory Range for Pipe & Cable Location Equipment GENERAL PURPOSE SONDE The C.SCOPE 8kHz and 33kHz General Purpose Sondes are transmitters used to trace the direction

More information

CALYS 75. Field documenting multifunction calibrator

CALYS 75. Field documenting multifunction calibrator Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.

More information

Floor-Mounted Tubfiller

Floor-Mounted Tubfiller Floor-Mounted Tubfiller Installation Guide TSP510 TSU510 2012-04 Attention Before Installation 1. Inspect this product to ensure you have all parts as shown that are required for proper installation. 2.

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for VPI46 SAY..P.. with a 15 mm stroke Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20

More information

luxury HEATED & NON-HEATED TOWEL RAILS

luxury HEATED & NON-HEATED TOWEL RAILS luxury HEATED & NON-HEATED TOWEL RAILS Heated & Non-Heated Towel Rails COMFORT+STYLE+ luxury EXCEED expectations Radiant Heating have been at the forefront of providing quality heated towel rails and quality

More information

Aqua-Gen 3PV INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS Aqua-Gen 3PV INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for valves SAY..P.. with a 15 mm stroke SAY31P03 Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS Model # 2040-4261 Model # 2480-4261 Congratulations on the purchase of your Newport Brass product, an excellent choice, that will give you years of quality

More information

Communicative heating controller

Communicative heating controller UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection

More information

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515, LR8520 For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection Please see www.hioki.com

More information

Aqua-Gen 3BR INSTRUCTIONS

Aqua-Gen 3BR INSTRUCTIONS Aqua-Gen 3BR INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

Heat meter Q heat 5 US

Heat meter Q heat 5 US Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement

More information

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH INSTALLATION INSTRUCTIONS CW-00 WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M-0 ROUGH CB-00 BLACK ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M-0 ROUGH CW-0 WHITE

More information

LEVER SERIES Installation & Maintenance Instructions

LEVER SERIES Installation & Maintenance Instructions LEVER SERIES Installation & Maintenance Instructions LEV150 Ceramic Disc LJV150 Jumper Valve LEV80 Ceramic Disc LJV80 Jumper Valve I00018_Oct 17 Call 1300 369 273 www.enware.com.au Enware Australia Pty

More information

NEW CIRCUIT PROTECTIONRANGE

NEW CIRCUIT PROTECTIONRANGE NEW CIRCUIT PROTECTIONRANGE TRUSTED PROTECTION FOR YOUR RESIDENTIAL AND COMMERCIAL INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW RCBO, RCCB AND MCB RANGE PROTECTION

More information

WASHING MACHINE AND WASHER-DRIER

WASHING MACHINE AND WASHER-DRIER GB 99-11-03/01 1-14 Index 1 CONFORMITY OF APPLIANCE 3 2 DIMENSIONS OF WASHING MACHINE/WASHER-DRIER AND HOUSING SPACE 3 3 UNPACKING 4 4 LEVELLING 5 5 FITTING THE FRONT PANEL AND INSERTING THE MACHINE INTO

More information

Short form User Manual

Short form User Manual Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:

More information

BAÑO Full Pressure Balancing System Shower and Slidebar with. Handshower (Rough & Trim) G-7288-C15S

BAÑO Full Pressure Balancing System Shower and Slidebar with. Handshower (Rough & Trim) G-7288-C15S Full Pressure Balancing System Shower and Slidebar with Handshower (Rough & Trim) G-7288-C15S Concealed Pressure Balancing Valve Rough w/diverter G-7055 G-7055 1/2 Rough Valve w/diverter c u t t i n g

More information

CALYS 100. Field precision documenting multifunction calibrator

CALYS 100. Field precision documenting multifunction calibrator Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench

More information

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide Enterprise Moveable Workstations KEWAUNEE encouraging new discovery...worldwide Movable Workstations Self-supporting workstations Single and double sided Adjustable height worksurfaces Integrated shelving

More information

ACE MINI-LINE INSTALLATION GUIDE / HANDY HINTS

ACE MINI-LINE INSTALLATION GUIDE / HANDY HINTS ACE MINI-LINE INSTALLATION GUIDE / HANDY HINTS Please note - Ace Gutters Pty Ltd supply Rainwater Product Installations Guides to assist our customers. Ace Gutters are not responsible for the design of

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Instruction Manual DESCRIPTION The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Aquasun 3 RP Instruction rb2.docx 1 INSTALLATION INSTRUCTIONS

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FURNITURE VALENCIA Single Drawer Vanity W oodgrain Models C ontemporary design and quality construction, providing affordable storage for bathrooms of any siz e or style. It s

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10

More information

Electromotoric actuators for stroke valves

Electromotoric actuators for stroke valves s ACVATIX Electromotoric actuators for stroke valves SAS.. Electromotoric actuators with 5.5 mm stroke and 400 N positioning force SAS31.. Operating voltage AC 230 V, 3-position control signal Operating

More information

PRECISA 201 page 41. Torches MIG/MAG page 42 Wear parts for MIG/MAG torches page 43

PRECISA 201 page 41. Torches MIG/MAG page 42 Wear parts for MIG/MAG torches page 43 CHAPTER welding WELDING Transformer technology power sources EASYMIG 0 / / / DUAL page MAXISTAR 0 M / 00 M / 0 T / 0 T page BLUMIG C / C / C / C / C / C page BLUMIG 0 S / S / 0 S / 0 S page TF 00 / 00

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Leica Digisystem Safe and fast location of underground services

Leica Digisystem Safe and fast location of underground services Leica Digisystem Safe and fast location of underground services Leica Digisystem Making Cable Avoidance Easier and Safer Every year site workers are injured due to inadvertently striking buried utilities

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

HDU-SF (Horizontal Distribution Units - Single Flat)

HDU-SF (Horizontal Distribution Units - Single Flat) MAKING MODERN LIVING POSSIBLE Service Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language

More information

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke s 4 503 ACVATIX Electromotoric actuators for valves SAV.. with a 20/40 mm stroke SAV31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4

More information

Wall Profiles 2 Pozi Screwdriver. Wall Profile Covers 4 Sealant. Large Panel and Thin Panel Assemblies Sealant Gun

Wall Profiles 2 Pozi Screwdriver. Wall Profile Covers 4 Sealant. Large Panel and Thin Panel Assemblies Sealant Gun Decem Sliding Door (Corner Fitting) Instruction Manual DXT Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

CALYS 50. Field multifunction calibrator for basic use

CALYS 50. Field multifunction calibrator for basic use Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field

More information

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950)

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950) Tub & Shower PL950 Installation Instructions 3/ Thermostatic Valve Rough-in & Trim (PL950) CONTENT 0 - Valve & stop vlave specifications 03 - Face plate specifications 0 - Handle specifications 05 - Shower

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Flash Shower Valve Rough With Screwdriver Stops Thank you for selecting American-Standard... the benchmark of fine quality for over 0 years. To ensure that your installation proceeds smoothly-please read

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Accutech AM20. Wireless acoustic monitor field unit

Accutech AM20. Wireless acoustic monitor field unit Accutech AM20 Wireless acoustic monitor field unit 1 The Accutech AM20 wireless acoustic monitor field unit monitors pressure relief valves, steam traps, automatic tank cleaning (CIP) systems, and other

More information

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY TT403- K (1000W) Wireless Inline Switch Product Description The TT403- K is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs European Electronic Controls Catalogue Catalogue Section A Product Bulletin TS-9100 Issue Date 09 2000 TS-9100 Electronic Sensors and Transducers I ntroduction The TS-9100 series of electronic temperature

More information

SN+ MID MASTER + APPLICATION WATER METERS

SN+ MID MASTER + APPLICATION WATER METERS SMART THINKING WATER METERS MASTER + SINGLE-JET DRY WATER METERS DN25, DN32, DN40 MID R 100 Master+ is a single-jet dry meter intended to measurement of quantity of consumption. Thank to modern construction

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

HBS-AP ASSEMBLING INSTRUCTIONS

HBS-AP ASSEMBLING INSTRUCTIONS ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,

More information

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products

More information

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit Shower Only PL8900-00 & TR-SH Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit - Installation Instructions Before Your Installation Read

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20

More information