M-2980A Weatherproof Capacitor Control Cabinet

Size: px
Start display at page:

Download "M-2980A Weatherproof Capacitor Control Cabinet"

Transcription

1 M-2980A Weatherproof Capacitor Control Cabinet Molded Lexan Enclosure Shown With Optional M-6280A Capacitor Bank Control NEMA 4x rated enclosures available in the following construction materials: Nonmetallic Polycarbonate Molded Lexan Cold Rolled Steel Stainless Steel UV resistant Locking clasps accept 3/8" hasp locks Flexible configurations allow adaptation to a wide range of applications Industry Leader Since 1969 Made in the USA

2 Application Each M-2980A enclosure can be configured with the optional support equipment to match the existing control application and environment or supplied completely empty. See the Optional Equipment section for details regarding the optional equipment available. Construction Polycarbonate Body and door fabricated from nonmetallic polycarbonate EPDM gasket (ethylene propylene diene Monomer- M-class) External adjustable mounting bracket Nonmetallic door hinges Enclosure door accommodates optional power supplies, battery and communications devices External Grounding stud provided Molded Lexan Body and door fabricated from molded Lexan EXL 9330 Copolymer (.150" nominal thickness) UV Inhibitor Passed drop test on all eight corners Flame Retardant UL 94V-0 NEMA 4X water ingress and corrosion protection Stronger than standard polycarbonate Excellent low temperature impact strength (11 ft. lb. -60 F) ASTM D256 Silicone closed cell gasket External adjustable mounting bracket Integral door hinges with stainless steel hinge pin Enclosure door accommodates optional power supplies, battery and communications devices External Grounding stud provided Cold Rolled Steel/Stainless Steel (304) Body and door fabricated from 14/16 gauge steel Continuously welded seams ground smooth Closed cell neoprene gasket External adjustable mounting bracket Stainless steel door hinge Enclosure accommodates optional power supplies, battery and communications devices External Grounding stud provided Powder coated, ANSI 70 Grey Lexan is a registered trademark of General Electric company 2

3 Cabinet to Capacitor Bank Interface Type Meter Socket Mount Integrated 4, 5 or 6 Blade (4 Blade Standard) Meter Socket Plug M 2980A Capacitor Control Cabinet Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration (4S, 5S and 6S) (Figure 1) Optional custom factory Meter Socket Plug wiring configurations available (Figure 1) Direct Pole-Mount with cabled Meter Socket Plug 4, 5, or 6 Blade (4 Blade standard) Meter Socket Plug with standard five foot control cable Standard Meter Socket Plug wiring is available in factory 4, 5 and 6 Blade configuration Optional cable lengths available in five foot increments up to 50 feet Optional Factory Meter Socket Plug Custom Wiring Configurations available (Figure 1) Direct Pole-Mount with Cannon Connector, Integrated 5-Pin Cannon Connector (Figure 2), Cannon Bulkhead Shell Pin Cannon Connector (Figure 3), Cannon Bulkhead Shell Optional 5 and 7-Pin wiring configurations available (Figures 2 and 3) Direct Pole-Mount with Cannon Connector, Cabled 5-Pin Cannon Connector Shell (Figure 2) 7-Pin Cannon Connector Shell (Figure 3) Optional 5 and 7-Pin wiring configurations available (Figures 2 and 3) Optional cable lengths available in five foot increments up to 50 feet Direct Pole-Mount with cable only, no connector 3

4 Meter Socket Wiring 4 Blade Selection Config S Line Neutral OPEN CLOSE Line Neutral CLOSE OPEN Neutral Line OPEN CLOSE Jaw Base 43 Neutral Line CLOSE OPEN Config 5S 51 5 Blade Selection Line Neutral OPEN CLOSE NC POL Line Neutral OPEN CLOSE LC POL Jaw Base 6 Blade Selection Config S Line Neutral LC POL NC POL OPEN CLOSE 61 Line Neutral LC RTN LC POL OPEN CLOSE LC RTN Line Neutral Neutral Line NC RTN OPEN NC POL LC POL OPEN CLOSE CLOSE Line LC POL Neutral Neutral NC POL Line LC POL OPEN OPEN ALT LC POL CLOSE CLOSE 6 Jaw Base 66 LC POL Neutral Line OPEN LC RTN CLOSE Neutral Line OPEN CLOSE 68 LC POL Neutral Line OPEN CLOSE 69 Line Neutral OPEN CLOSE View as shown, is peering into female Meter Socket CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations. Figure 1 Standard (S) and Optional Factory Meter Socket Plug Custom Wiring Configurations 4

5 Config 5-Pin Cannon Plug/Control Wiring PIN A B C D E 5E Line Neutral CLOSE OPEN Control TB1-10 TB1-8 TB1-5 TB N Control 5L Control Line Neutral CLOSE OPEN NC POL TB1-10 TB1-8 TB1-5 TB1-6 TB1-14 Line Neutral CLOSE OPEN LC POL TB1-10 TB1-8 TB1-5 TB1-6 TB2-5 D E A NC POL - Neutral Current Polarity LC POL - Line Current Polarity NC RTN - Neutral Current Return LC RTN - Load Current Return C 5-Pin Plug B CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations. Figure 2 5-Pin Cannon Plug Configurations 5

6 7-Pin Cannon Plug/Control Wiring PIN Config A B C D E 7A Line OPEN CLOSE NC POL Control TB1-10 TB1-6 TB1-5 TB1-14 F G Neutral TB1-8 7B Control Line OPEN CLOSE NC POL TB1-10 TB1-6 TB1-5 TB1-14 LC POL TB2-5 Neutral TB1-8 7C Line Neutral CLOSE OPEN Control TB1-10 TB1-8 TB1-5 TB1-6 LC POL TB2-5 LC RTN TB2-4 7D LC POL NC POL Line CLOSE OPEN NC & LC RTN Control TB2-5 TB1-14 TB1-10 TB1-5 TB E Control Line OPEN CLOSE NC POL NC & LC RTN TB1-10 TB1-6 TB1-5 TB1-14 LC POL TB2-5 Neutral TB1-8 7F Line Neutral CLOSE OPEN GROUND Control TB1-10 TB1-8 TB1-5 TB1-6 LC POL TB2-5 LC RTN TB2-4 F G A NC POL - Neutral Current Polarity LC POL - Line Current Polarity NC RTN - Neutral Current Return LC RTN - Load Current Return E B D C 7-Pin Plug CAUTION: Neutral Current or Phase Current input wires located in the same physical cable as Line-in, Open, and Close wiring may experience induced Neutral Current and/or Phase Current transients during Opening and Closing operations. Figure 3 7-Pin Cannon Plug Configurations 6

7 3-Pin Cannon Connector/Control Wiring Config Line Current Line Post Sensor Control PIN A B C LC POL LC RTN Ground TB2-5 TB2-4 Enclosure Ground Stud A-BLACK* (LC POL) 3-Pin Socket (Cabinet Side) C-Green* or Bare Wire B-White* (LC RTN) LC POL - Line Current Polarity LC RTN - Load Current Return Wire color coding * does not apply to control terminal block wiring. Config Neutral Current 50:0.2 CT Control A B C NC POL NC RTN Ground TB1-14 TB1-15 Enclosure Ground Stud A-BLACK* (NC POL) NC POL - Neutral Current Polarity NC RTN - Neutral Current Return C-Shield 3-Pin Plug (Cabinet Side) B-Red* (NC RTN) * Wire color coding does not apply to control terminal block wiring. Figure 4 3-Pin Cannon Plug Configurations 7

8 Optional Equipment/Accessories M-6280A Digital Capacitor Bank Control M-6283A Three-Phase, Independent Phase Switching Digital Capacitor Bank Control Pole mount bracket (Figure 13) NOTE: Refer to Figure 9 for referenced cabinet sensor and antenna locations. Load Current Sensor Options Include: 15 KV Fisher Pierce Line Post Sensor - Includes 35 ft. cable with 3-Pin Cannon connector (Figure 4) and Cabinet Side Connection. 15 KV Lindsey Line Post Sensor 30 Foot Cable for Lindsey Line Post Sensor Neutral Current Sensor Options Include: Caution: Use of a Fisher Pierce AT-929 for Neutral Current input to the M-6283A Control without Jumper JP1 placed in the A-B position will result in damage to the control and the display of an error code. CAUTION: Use of a Fisher Pierce AT-929 for Neutral Current input to the M-6280A control without a B 1391 Resistor Assembly installed between TB1 14 and TB1 15 will result in damage to the control and the display of an error code. 50:0.2 CT Neutral Current Sensor terminated with 3-Pin Cannon connector (Figure 4) using customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable. Includes Cabinet Side Connections installed in hole location N. 50:0.2 CT Neutral Current Sensor with customer specified (10, 20, 35, or 45 foot) length of shielded twisted pair cable. Cannon Connector, cabinet side 3-Pin (Figure 4) Antenna Cable & Bulkhead Connector (For Installation with Antennas Mounting Direct to Cabinet) options include: TNC male to N female weatherproof bulkhead and antenna cable for lid mount. SMA male to N female weatherproof bulkhead and antenna cable for lid mount. SMA male to N female weatherproof bulkhead and antenna cable for cabinet mount. Double-D Hole for "N" connections in location 1, 2, 3 or 4 of cabinet to accommodate antenna exit. Lightning Protection (For installations with external antennas) options include: DSXL PolyPhaser Lightning Arrestor 700MHz - 2.7GHz N Female protected side, N Female Bulkhead antenna side. AL-LSXM PolyPhaser Lightning Arrestor 2 GHz to 6 GHz N Female protected side, N Female Bulkhead antenna side. SMA male to N male antenna cable to connect lightning protection to a radio for cabinet mount. TNC male to N male antenna cable to connect lightning protection to a radio for cabinet mount. Antennas: Laird FG9023, 902 MHz to 928 MHz, 3 dbi gain, fiberglass Omnidirectional antenna, N Female connector. FM2, antenna Pole Mount Bracket for Laird fiberglass antennas. Laird TRAB9023NP, 902 MHz to 928 MHz, 3 dbi gain, Omnidirectional Phantom antenna, N Female bulkhead connector. SMA male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount. TNC male to N male antenna cable to connect antennas with an integrated bulkhead to a radio for cabinet mount. 8

9 Optional Equipment/Accessories (Cont. d) Radio Options Include: 2 Way VHF (154 MHz) radio Radius 2 Way (130 MHz GHz) radio modems: SilverSpring Networks SSN ebridge and sbridge MDS INET 900 AP MDS INET II MDS SD9 MDS X710 MDS SD4 MDS 9810 MDS TransNET MDS Mercury 3650 and 900 MDS entranet 900 and 2400 CellNet Series III Digital Cellular Modems: Sixnet BT series Mobility Pro/Industrial Pro Gateways Multitech Multimodem series routers and modems AirLink Raven II, X, XE Zywan 3G/GPRS/GSM Cellular Modem Radio ready options include: Universal Radio Bracket Universal Radio Bracket with 12 Vdc or 24 Vdc power supply Universal Radio Bracket with customer supplied power supply installed Radio, Factory Installation: Radio mounted and installed to M-2980A Customer supplied radio mounted and installed to M-2980A RS-232 Radio Comm Cable - 30" length. Connects M-6280A/M 6283A Control to radio s DB9 Port Ethernet Radio Comm Cable - 24" length. Connects M-6280A/M 6283A Control to radio s RJ45 Port Universal Power Cable provides fused 120 Vac to power a radio power supply (Included on all radio brackets) DB9 to DB25 - RS-232 Cable Converter Intrusion Detection Microswitch assembly 1/2" HEYCO Liquid Tight Cordgrip to secure cable coming into cabinet via hole location "T" or "B". Universal Radio/Modem Bracket (For field mounting in the door of the M-2980A Cabinet) 12 Vdc Power Supply for radio 24 Vdc Power Supply for radio 25 foot N male to N male LMR-400 antenna extension cable 9

10 Optional Equipment/Accessories (Cont. d) Battery Backup Power The Battery Backup option provides backup power to the control, and radio (if equipped). The Battery Backup system consists of: XP Power Model Number BCS75US13C Input Voltage: Vac ( Vdc) Frequency: Hz Current: 75 W: 1.5/1.0 A max 115/230 Vac Power Factor: Meets EN , Class A Input Protection: Internal 4.0 A, 250 V fuse, fitted in line Input Protection: External 6.3 A, 250 V fuse, fitted in line Output Power Output Power: 75 W Output 1: 13.8 V, 5.50 A Output 2: 13.8 V, 1.95 A Efficiency: 86% Environmental Operating Temperature: -20 C to +70 C Cooling: 75 W, Convection-cooled Operating Humidity: 95% RH, non-condensing Storage Temperature: -40 C to +85 C Operating Altitude: 2000 m Shock: 30 g pk, half sine, 6 axes Vibration: 2 g rms, 10 Hz to 500 Hz, 10 min/cycle for 60 mins on each axis Compliance Emissions: EN55022, Level B conducted and radiated Harmonic Currents: EN , class A Voltage Flicker: EN ESD Immunity: EN , level 3 Perf Criteria A Radiated Immunity: EN , 3 V/m Perf Criteria A EFT/Burst: EN , level 2 Perf Criteria A Surge: EN , installation class 3, Perf Criteria A Conducted Immunity: EN , 3 V Perf Criteria A Dips & Interruptions: EN , 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals: EN , UL

11 Optional Equipment/Accessories (Cont. d) CYCLON Battery BC Single Cell Model Number Voltage: 12.0 Vdc Capacity: 8.0 Ah This product contains a non-spillable, sealed pure lead battery cell pack, which has been accepted by the Department of Transportation in compliance with tests found in 49 CFR (d). The rugged construction of the battery pack is rated for -65 C to +80 C (-85 F to +176 F) service environment. The battery pack is supplied in a charged condition capable of extremely high energy short circuit currents. Required Storage Parameters to Maintain Charge Capacity During storage batteries lose charge capacity by self-discharge. The recommended recharge interval is every 6 months from date of receipt. To maintain charge capacity, check the charge every 6 months. Temperature: 25 C Humidity: Maximum relative humidity 80% for temperatures up to 31 C, decreasing to 31 C linearly to 50% relative humidity at 40 C. Environment: Storage area to be free of dust, corrosive gases, flammable materials, dew, percolating water, rain and solar radiation. 11

12 CAUTION: Avoid short-circuiting terminals and wire terminals of opposite polarity. L N (AC In) CN1 Gnd V0+ B+ B- N.C CN2 Figure 5 Battery Backup Power Connections Figure 6 Battery Backup Power Orientation in Cabinet 12

13 Installation of Battery Cell Pack The optional Battery Cell Pack is shipped loose with the M-2980A cabinet. The following instructions describe the installation of the Battery Cell Pack. Caution: Observe all Cautions previously listed when installing the Battery Cell Pack. Caution: Do not short the Positive and Negative Terminals when installing the Battery Cell Pack. The Battery Cell Pack is capable of extremely high energy short circuit currents. 1. Install the Battery Cell Pack as shown in Figure 7, with the Negative Terminal towards the bottom of the cabinet door and the Positive Terminal towards the top of the cabinet door. Figure 7 Battery Cell Pack Orientation 2. Fasten the restraining straps by threading the small end of the strap through the second slot of the other end of the strap (Figure 8), then pull tight (about 15 lbs). Thread the small end back through the same slot, this will keep it out of the way and make it easier to remove in the future. Figure 8 Battery Cell Pack Restraining Straps 3. Connect the Negative marked White wire to the Battery Cell Negative Terminal and the Positive marked Red wire to the Battery Cell Positive Terminal. 13

14 Physical Polycarbonate Cabinet Size: 15.69" high x 13.19" wide x 7.27" deep (39.9 cm x 33.6 cm x 18.5 cm) Approximate Weight: 9 lbs (4.1 kg) Approximate Shipping Weight: 13 lbs, 5 oz (6.05 kg) Approximate Weight with M-6280A/M 6283A Digital Capacitor Bank Control: 15 lbs, 5 oz (7.02 kg) Approximate Shipping Weight with M-6280A/M 6283A Control: 23 lbs, 10 oz (10.61 kg) Molded Lexan Cabinet Size: 18.38" high x 12.43" wide x 7.81" deep (46.7 cm x 31.6 cm x cm) Approximate Weight: 10 lbs, 8 oz (4.76 kg) Approximate Shipping Weight: 12 lbs (5.44 kg) Approximate Weight with M-6280A/M 6283A Digital Capacitor Bank Control: 18 lbs (8.17 kg) Approximate Shipping Weight with M-6280A/M 6283A Control: 21 lbs, 8 oz (9.75 kg) Cold Rolled Steel/Stainless Steel (304)B7B346 Size: 22.6" high x 11.38" wide x 10.09" deep (57.5 cm x cm x cm) Approximate Weight: 16 lbs, 8 oz (7.48 kg) Approximate Shipping Weight: 24 lbs (10.89 kg) Approximate Weight with M-6280A/M 6283A Digital Capacitor Bank Control: 23 lbs, 8 oz (12.36 kg) Approximate Shipping Weight with M-6280A/M 6283A Control: 36 lbs (16.33 kg) NOTE: Add approximately 7.5 lbs (3.4 kg) when equipped with Battery Backup option. Warranty The M 2980A Weatherproof Capacitor Control Cabinet is covered by a five year warranty from date of shipment. Third party mounted options will carry their respective manufacturer s warranty, passed along through Beckwith Electric. Specification subject to change without notice. 14

15 2 TOP CABINET ANTENNA CABLE HOLE T TOP INTERFACE HOLE 1 TOP LID ANTENNA CABLE HOLE 3 BOTTOM LID ANTENNA CABLE HOLE 4 BOTTOM CABINET ANTENNA CABLE HOLE L LOAD CURRENT SENSOR HOLE N NEUTRAL CURRENT SENSOR HOLE B BOTTOM INTERFACE HOLE Figure 9 Cabinet Antenna Mounting and Sensor Location Options 15

16 Polycarbonate Meter Socket Mount Cabinet Radio Antenna Mounting Hole Radio Antenna Mounting Hole 4, 5 or 6 Blade Meter Socket (4 Standard) Factory Custom Wiring Available Nonmetallic Door Hinges External Grounding Stud Stainless Steel Locking Clasps Accept up to 3/8" Hasp Locks Cabinet Door Accomodates Optional Power Supplies and Communication Devices Lexan Meter Socket Mount Cabinet Radio Antenna Mounting Hole 4, 5 or 6 Blade Meter Socket (4 Standard) Factory Custom Wiring Available Radio Antenna Mounting Hole Integrated Door Hinge With Stainless Steel Hinge Pin Stainless Steel Locking Clasps Accept up to 3/8" Hasp Locks External Grounding Stud Cabinet Door Accomodates Optional Power Supplies and Communication Devices Figure 10 Meter Socket Mount 16

17 Polycarbonate Pole Mount Cabinet M 2980A Capacitor Control Cabinet Adjustable Direct Pole Mounting Bracket Adjustable Direct Pole Mounting Bracket Nonmetallic Door Hinges Stainless Steel Locking Clasps Accept up to 3/8" Hasp Locks External Grounding Stud Standard 5' Control Cable (Optional cable lengths in five foot increments up to 50 feet) 4, 5 or 6 Blade Meter Socket Plug (4 Standard) Factory Custom Wiring Available Cabinet Door Accomodates Optional Power Supplies and Communication Devices Adjustable Direct Pole Mounting Bracket Radio Antenna Mounting Hole Lexan Pole Mount Cabinet Integrated Door Hinge With Stainless Steel Hinge Pin Adjustable Direct Pole Mounting Bracket Radio Antenna Mounting Hole Stainless Steel Locking Clasps Accept up to 3/8" Hasp Locks External Grounding Stud Standard 5' Control Cable (Optional cable lengths in five foot increments up to 50 feet) 4, 5 or 6 Blade Meter Socket Plug (4 Standard) Factory Custom Wiring Available Cabinet Door Accomodates Optional Power Supplies and Communication Devices Figure 11 Polycarbonate and Lexan Pole Mount Cabinet and Meter Socket Plug 17

18 Cold Rolled Steel/Stainless Steel Pole Mount Cabinet Adjustable Direct Pole Mounting Bracket Adjustable Direct Pole Mounting Bracket Stainless Steel Locking Clasps Accept up to 3/8" Hasp Locks Stainless Steel Door Hinge Cabinet Accomodates Optional Power Supplies and Communication Devices Standard 5' Control Cable (Optional cable lengths in five foot increments up to 50 feet) External Grounding Stud 4, 5 or 6 Blade Meter Socket Plug (4 Standard) Factory Custom Wiring Available Figure 12 Cold Rolled Steel and Stainless Steel Pole Mount Cabinet and Meter Socket Plug 18

19 R R [Millimeters] B-1225 Cable 5 Pin Connector Shown, B1234 Meter Base Adapter Cable Figure 13 Polycarbonate Cabinet Dimensions 19

20 9.56 [24.3] 7.80 [19.8] [31.6] [57.5] [46.7] 20.0 [50.7] [54.9] Meter Base Mount Shown for Reference Figure 14 Lexan Cabinet Dimensions 20

21 R 0.22 [0.56] 2.25 [5.72] 9.93 [25.22] 2X Ø 0.53 [1.53] [1.27] 1.13 [2.87] C L 0.65 [1.64] 0.50 [1.27] 7.34 [18.64] [27.69] R 0.56 [1.42] 3.70 [9.4] 1.85 [4.7] [57.5] [44.5] [51.77] R 0.27 [0.69] 2X R 0.34 [0.86] C L 2.75 [6.99] 0.50 [1.27] 9.88 [25.01] [28.91] 0.67 [1.7] 1.85 [4.7] Figure 15 Cold Rolled Steel/Stainless Steel Cabinet Dimensions 21

22 BECKWITH ELECTRIC CO., INC th Avenue North Largo, Florida U.S.A. PHONE (727) FAX (727) ISO 9001: Beckwith Electric Co. All Rights Reserved. Printed in U.S.A. ( ) A SP 04MC1 02/17

Digital Capacitor Bank Control M-6280A

Digital Capacitor Bank Control M-6280A CONTROLS Digital Capacitor Bank Control M-6280A Digital Capacitor Bank Control for Remote Capacitor Automation, Monitoring and Protection Maximum Communication Options For Wired or Wireless Networks RS-232,

More information

Current Loop Interface Module M 2025D

Current Loop Interface Module M 2025D CONTROLS Current Loop Interface Module M 2025D Current-to-Voltage Analog Converter used with the M 2001 Series Digital Tapchanger Control and M-2948 Tap Position Sensors to provide positive tap position

More information

TB65 65W Single Output Test and Measurement/Industrial Series

TB65 65W Single Output Test and Measurement/Industrial Series Features 2.0 x 3.5 x 1.3 Package TB65 Up to 65W Convection Cooled Output Power Compliant to high levels of EMC per EN61000-4 15kV ESD (Air), 8kV (Contact) 4kV Surge Meets Class B Conducted EMI with 6db

More information

General. Environmental. EMC & Safety

General. Environmental. EMC & Safety 65// Watts ECS Series IT & Medical Safety Approvals xppower.com 65// W - Ratings Class I & Class II Construction Industry Standard 2 x 4 Package

More information

Current Loop Interface Module M-2025C

Current Loop Interface Module M-2025C CONTROLS Interface Module M-2025C Current-to-Voltage Analog Converter used with the M-2001 Series Digital Tapchanger Control and M-2948/M-2949 Tap Position Sensors to provide positive tap position knowledge

More information

M 6283A Three Phase Digital Capacitor Bank Control

M 6283A Three Phase Digital Capacitor Bank Control CONTROLS M 6283A Three Phase Digital Capacitor Bank Control Three Phase Sensing Digital Capacitor Bank Control for Remote Capacitor Automation, Monitoring and Protection Control Universal control offering

More information

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W AEL15-80 Series 15-80 Watts Energy Efficiency Level V CEC 2008 and EISA 2007 Compliant Limited Power Source Approval China Compulsory Certification (CCC) Qualified +60 C Operating Temperature Compact Dimensions

More information

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5 Single Output Audio Visual Renewable FEATURES AND BENEFITS Automation Broadcast Industrial Display & Signage ITE & Comms Lighting Military COTS Test & Measurement Compact size: 6.5 x 2.8 x 1.5 Meets DoE

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

IN-BUILDING ANTENNAS

IN-BUILDING ANTENNAS Ceiling Mount Antenna, 4G LTE MIMO, PIM160 VenU PIM160-ICM Ultra Flat Dual-Polarization LTE MIMO Ceiling Mount Antenna The PIM160-ICM is a dual-polarization LTE MIMO antenna with ultra-low PIM (@ 2x43

More information

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26 Total Power: 65-75 W Input Voltage: 85-264 VAC 120-370 VDC* # of Outputs: Single, dual, triple SPECIAL FEATURES Universal Input 3 x 5 footprint Low profile fits 1U applications EN61000-3-2 compliance option

More information

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DSR120 Series. xxx Series. 120 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 120 Watts xxx Series Ultra Slim Design - 32 mm 150% Peak Load for 3 seconds Ambient Operation from -25 C to +70 C Full Load at 60 C (24V/48V) High Efficiency - Up to 92% Volt-Free Contact for OK Selectable

More information

TE W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 120W of AC-DC Power Universal Input 90-264Vac Input Range IPX-2 Rated Enclosure for protection against liquid

More information

Watts HCP Series

Watts HCP Series ACDC 6 Watts HCP Series High Efficiency up to 9% xppower.com High Power Density Programmable Output Voltage (%%) Programmable (%%) Parallel Operation Fully Featured Signals & Controls Year Warranty Specification

More information

LB115S 115W Single Output

LB115S 115W Single Output Features Small size of 2 x 4 x 1.3 75W convection cooled/115 Watts with 200 LFM Universal Input 90-264Vac Meets EN55015 Conducted EMI Meets IEC61000-3-2 Class C for less than 1 Watt to full power Approved

More information

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets Heavy Industrial Levels

More information

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

NEW TOUGHEST WIND SENSORS THE WORLD S  1:2 F T 74 2 D ATA S H E E T NEW S U R FA C E M O U N T D E S I G N E D F O R I N T E G R AT I O N THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM 1:2 PROVEN IT LOOKS DIFFERENT BECAUSE IT IS DIFFERENT

More information

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features LPS Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 20W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy

More information

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15 Total Power: 40-50 W Input Voltage: 90-264 VAC 120-370 VDC # of Outputs: Single, dual, triple SPECIAL FEATURES 4.25 x 2.5 x 1.15 inch package (1U applications) Universal input Overvoltage and short circuit

More information

HNRRKIT. Hangar Networked Re-Radiating Kit Technical Product Data

HNRRKIT. Hangar Networked Re-Radiating Kit Technical Product Data HNRRKIT Hangar Networked Re-Radiating Kit Technical Product Data Features Amplified Roof Antenna Gain 35dB Re-Radiating Amplifier with Power Supply Typical Gain 30dB Optional Mounting Kit Hardware Roof

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

Specif ications. S&C IntelliCap 2000 Automatic Capacitor Control

Specif ications. S&C IntelliCap 2000 Automatic Capacitor Control Specif ications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified by the SPECIAL WARRANTY PROVISIONS and WARRANTY QUALIFICATIONS

More information

MB120S 120W Single Output Medical Series

MB120S 120W Single Output Medical Series Features 2 x 4 x 1.25 Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed

More information

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Meets Heavy Industrial Levels

More information

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet IMA 600 Watts Power Supply Series for medical and industrial applications Product datasheet 600 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 1000 Watts Power Supply Series for medical and industrial applications Product data sheet Features 1000 Watts Power Supply Series for medical and industrial applications Safety rated for Medical, Industrial

More information

TE40 40W Single Output External Power Test & Measurement/Industrial Series

TE40 40W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 40W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy Industrial

More information

TE90 90W Single Output External Power Test & Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series Features Meets U.S. DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 90W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets

More information

MDW-45 Converter RS RS-422/485

MDW-45 Converter RS RS-422/485 www.westermo.com MDW-45 Converter RS-232 - RS-422/485 2 6617-2203 General information Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties

More information

Electrical Specifications

Electrical Specifications Single & Quad output 1 of 5 Total Power: 80-110 W Input Voltage: 85-264 Vac 120-370 Vdc # of Outputs: Single, quad Special Features 7.0 x 4.25 x 1.8 inch package Overvoltage and short circuit protection

More information

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES 2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output

More information

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3 HPU1K5 Series Low Profile 1.7 (43.2 mm), Industrial Supply Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals Output Power up to 1500 W Load dependant variable speed fans for audible

More information

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark. The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as

More information

Electrical Specifications

Electrical Specifications POWER Data Sheet NLP65 Series Single, Dual and Triple Output Total Power: 65-75 W Input Voltage: 85-264 Vac 120-370 Vdc* # of Outputs: Single, dual, triple SPECIAL FEATURES Universal input 3 x 5 footprint

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Eight High Broadband ports covering PCS, AWS / AWS-3 and WCS bands (698-798 MHz, 824-896 MHz. & 1695-2360 MHz.) Four Low Band ports covering 700 MHz and 850 MHz bands Supports 8x8 MIMO in high

More information

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 400 Watts Power Supply Series for medical and industrial applications Product data sheet 400 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold Features 2 x 3.5 x 1.3 Package, Ideal for 1U Applications 10-year life design with Premium E-Caps 65 Watts convection cooled Class I and Class II models Class B Conducted and Radiated EMI Performance BF

More information

PDAM500 Series 500W Power Supply

PDAM500 Series 500W Power Supply UL / IEC / EN 60601 3.1 Edition & UL / IEC / EN 60950 AM2 Safety Approvals High power density: 500W in 3 x 5 footprint Open Frame or Enclosed Versions Available Remote ON/OFF Function Built-in 12V/0.3A

More information

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max. POWER Data Sheet NLP250 Series Single Output Total Power: 250 W Input Voltage: 85-264 Vac # of Outputs: Single SPECIAL FEATURES Active PFC and EN61000-3-2 compliant 250 W on main channel with forced air

More information

Electrical Specifications

Electrical Specifications POWER Data Sheet NFS110 Medical Series Single and quad output Total Power: 80-110 W Input Voltage: 100-240Vac 127-357 Vdc # of Outputs: Single, quad Special Features 7.0 x 4.25 x 1.8 inch package Medical,

More information

Beyond AMI. We Put You in Control When It Counts

Beyond AMI. We Put You in Control When It Counts CELLULAR COMMERCIAL LOAD CONTROL DEVICE WITH Beyond AMI We Put You in Control When It Counts LED Indicators Meter Seal Mounting Brackets ¾ MNPT Conduit Fitting Device Features Cost effective two-way remote

More information

Product Specification sheet

Product Specification sheet INPUT MINIMUM RATED MAXIMUM Input Voltage 90V AC 100 240V AC 264V AC Input Frequency 47 Hz 50 / 60 Hz 63 Hz Input Current * 350mA Inrush Current **

More information

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3 , Features High power density 40 W power supply (enclosed / open frame) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

General. Environmental. EMC & Safety

General. Environmental. EMC & Safety AC-DC 400-2500 Watts f lexpower Series Configurable for Fast Time to Market SEMI F47 Compliant xppower.com Flexible Series & Parallel Capability -20 C Operation Extra Power Available at High Line Optional

More information

Ten Port Multi-Band Antenna

Ten Port Multi-Band Antenna DATA SHEET Eight High Broadband ports simultaneously covering PCS, AWS / AWS-3 and WCS bands Eight High Broadband ports with two Low Band ports in one antenna Excellent elevation side-lobe performance

More information

GPS-ITS. GPS Indoor Testing Solution Technical Product Data. Features. Description. Amplified Roof Antenna Gain 35dB

GPS-ITS. GPS Indoor Testing Solution Technical Product Data. Features. Description. Amplified Roof Antenna Gain 35dB GPS-ITS GPS Indoor Testing Solution Technical Product Data Features Amplified Roof Antenna Gain 35dB Mounting Kit Hardware Roof Antenna Mount & Adjustable Re-Radiating Mount Variable Gain Amplifier with

More information

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850

More information

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms Features DIN Rail Description Universal AC Input (85264VAC) Protections: SCP, OVP, OLP, OTP DC OK Indicator LED with Relay Contacts 5% (8W) peak load capacity Builtin active PFC,PF>,95 High effciency up

More information

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION Nominal Input Voltage Max. Output Power Nominal Output Voltage Max. Output Current 120/277 Vac 12, 24, Vdc 5, 3.92 A Efficiency up to 90% typical Max. Case Temperature 100 C (measured at the hot spot)

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

Low Profile. 3 Year Warranty

Low Profile. 3 Year Warranty MCC Series 400 W Regulated Output Optional 200 W Non-regulated Conditioned Rail 1 to 4 Configurable Outputs MIL-STD-1275 and DEF-STAN 61-5 MIL-STD-461 and DEF-STAN 59-411 Low Profile Rugged Construction

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6. IXARC Incremental Encoder UCD-IPT00-08192-M100-PRD Interface Interface Programmable Incremental Programming Functions PPR (1-16384), Output, Counting Direction Configuration Tool UBIFAST Configuration

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE TAD 65 U B - xx yy - Series Name Output Input Output Output Output Output Output Protection

More information

Electrical Specifications

Electrical Specifications 450 Watt Medical Features 4 x 6.5 x 1.61 inches Approval to EN60601 3rd Edition Dual Fusing Current Sharing Option Cover and Fan Options Peak Power Capability Class B EMI & Medical (BF) Safety Approvals

More information

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution Up to 350W Up to 6 outputs Voltages up to 28V, Current up to 50 mps Fast-on output connection Worldwide approvals 3 Year Warranty Sirius 250/350 Watts, Single / Multi output C-DC, modular power solution

More information

1000 ~ 3000W 1U Distributed Power System RCP-1U Rack System

1000 ~ 3000W 1U Distributed Power System RCP-1U Rack System Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 000 ~ 3000W U Distributed Power System RCP-U Rack System - File Name:RCP-U Rack System-SPEC 206-0-30 000 ~ 3000W U Distributed

More information

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet PX2 Series bar to 46 bar 00 kpa to 4.6 MPa 5 psi to 667 psi Datasheet Table. Electrical Specifications Characteristic Ratiometric Regulated Transfer Function Order Code (See Figure 5.) AA AB AC AD CH BC

More information

CB Scheme UL508 UL ATEX II3G

CB Scheme UL508 UL ATEX II3G Industrial Power Supplies UL Hazloc Class I, division 2 approval and ATEX certification SEMI F47 compliant for voltage sag immunity Rugged metal case with optional side-mounting Very high efficiency up

More information

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available. ECC100 Series -40 ºC to +75 ºC Operation 100 W - Baseplate Cooled High Efficiency Resonant Topology Screw Terminals Available 5V Standby Output Remote On/Off & Power OK Signal 3 Year Warranty The ECC100

More information

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet POWER Data Sheet NLP40 Series Single, Dual and Triple Output Total Power: 40-50 W Input Voltage: 90-264 Vac 120-370 Vdc # of Outputs: Single, dual, triple SPECIAL FEATURES 4.25 x 2.5 x 1.15 inch package

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Four foot (1.2 m) multiband, twelve port antenna with a 65 azimuth beamwidth covering 698-798 MHz, 824-896 MHz and 1695-2360 MHz frequencies Total of Eight high band ports, four high wide band

More information

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated. KEY FEATURES Open Frame Switching Power Supply Remote ON/OFF Function 240 Watt with Free Air Convection 500 Watt with 30CFM FAN Built-in 12V/0.3A Auxiliary Output Standby 5V@1A with Fan, @0.4A without

More information

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC 10KV Lightning Surge Protection Smart Over-Temperature Protection Universal AC Input up to 305Vac High Efficiency (Up to 92%) Active Power Factor Correction Constant Current With Dimming Options Waterproof

More information

MaxWave 4x4 MIMO Train Antenna

MaxWave 4x4 MIMO Train Antenna Electrical Features High Efficiency Superior Isolation Patented Pattern Diversity System Features 4x4 Cellular MIMO 4x4 WiFi/WiMAX MIMO GPS/GLONASS Mechnical Features Fully Certified Rugged Design Standard

More information

LCE-MBP-400. User Manual. TDI Transistor Devices Inc. 85 Horsehill Road, Cedar Knolls, NJ USA Phone: Fax:

LCE-MBP-400. User Manual. TDI Transistor Devices Inc. 85 Horsehill Road, Cedar Knolls, NJ USA Phone: Fax: LCE-MBP-400 User Manual TDI Transistor Devices Inc. 85 Horsehill Road, Cedar Knolls, NJ 07834 USA Phone: 973.267.1900 Fax: 973.267.2047 Page 2 of 11 TABLE OF CONTENTS 1. Introduction 1.1 Description 3

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT CELLULAR POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAP00-S041911M2-1 Beyond AMI We Put You in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

More information

LFWLP W 12V 15.00A 25.00A 92%

LFWLP W 12V 15.00A 25.00A 92% WLP350 Series 350 Watts Low profile 1 5 x 3 footprint 200W / 350W Fan Up to 94% efficient Cover kits available EN55032 Level B conducted & radiated 5 Year warranty The LFWLP350 series of low profile, open

More information

DC/DC Converter K78_T-500R3 Series

DC/DC Converter K78_T-500R3 Series Wide input voltage Non-isolated and Regulated Single Output RoHS FEATURES High efficiency up to 95% No-load input current as low as 0.2mA Operating ambient temperature range -40 to +85 Output short-circuit

More information

150 Watt Industrial (WLT)

150 Watt Industrial (WLT) 150 Watt Industrial (WLT) Features 4 x 2 x 1.3 inches form factor 150 W with forced-air cooling Class 1 & Class 2 options 12 V @ 0.5 A fan voltage auxiliary output High efficiency > 86% Low conducted and

More information

wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution

wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution smart grid n automated meter infrastructure n distribution Ventev s product solutions

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

C B. Models. Models 2MOPP

C B. Models. Models 2MOPP AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to

More information

HX-EP SERIES DIGITAL OUTPUT

HX-EP SERIES DIGITAL OUTPUT HX-EP SERIES DIGITAL OUTPUT Utilizing an incremental encoder as the sensor, the UniMeasure HX-EP series position transducer provides a two channel square wave current sinking output signal in quadrature.

More information

Electrical Specifications

Electrical Specifications 300 Watt Industrial Features 3 x 5 x 1.5 inches Wide range AC input EMI Class B CE marked to LVD Class 1 & Class 2 options Input Voltage Input Frequency Electrical Specifications 90-264 VAC/120-390 VDC,

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Twelve Port Multi-Band Antenna Eight foot (2.5 m) multiband, twelve port antenna with a 45 azimuth beamwidth covering 698-960 MHz and 1695-2360 MHz frequencies Eight wide high band ports covering

More information

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter Features Regulated Converter Unique, patent-pending design Isolated power supply with integrated mains filter Packaged inside of line filter case Safe, touchable DC outputs Easy installation Worldwide

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices. The MBC40 Series of open-frame medical power supplies, with its wide universal 90-264 VAC input range, is available at 40 W of output power and a variety of single and multiple output voltages. The MBC

More information

VOF XX - XXX - X

VOF XX - XXX - X date 01/31/018 page 1 of 10 SERIES: VOF-300 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 300W continuous power universal input voltage range industry standard 3 x 5 footprint power factor correction

More information

Industrial Serie +600S

Industrial Serie +600S D A T A S H E E T Industrial Serie +6S Modular Configurable Reduced fan noise Enhanced Line Derating 6 watts in the palm of your hand The +6S series fetures improved low input line derating delivers 6

More information

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope Electrical Specification for: Compact PCI - 6U - AC - 700W Telkoor Part Number: 900-7802-0000 SCALE RELEASE DATE 11/11/13 SHEET 1 OF 7 VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

Hybrid Bi-SectorTM Array

Hybrid Bi-SectorTM Array DATA SHEET Eight foot (2.4 m), multiband, ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams

More information

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION 060W-12 100W-24 Nominal Input Voltage 90 &, Efficient, CV Class 2 Max. Output Power Nominal Output Voltage Max. Output Current 120 & 277 Vac 12, 24 Vdc 5, 3.75 A Efficiency up to 90% typical Max. Case

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max. WLP120 Industrial Features 3 x 2 foot print Height 1 above PCB 120 Watts with Forced Air Cooling Efficiencies upto 93% -40 to 70 degree operating temperature Thermal Shut-Down feature >3.00m Hours, Telcordia-SR332-issue

More information

[ tima-datasheet-en v11.1 ]

[ tima-datasheet-en v11.1 ] specifically designed for protection, automation and control applications in power systems 60 ns (99%) maximum time deviation single or dual 10/100Base-T Ethernet port(s) VLAN / IEEE 802.1Q support RS232

More information

Hughes 9450 Mobile Satellite Terminal Series. Installation Guide

Hughes 9450 Mobile Satellite Terminal Series. Installation Guide Hughes 9450 Mobile Satellite Terminal Series Installation Guide Document No. 3004129-0001 Revision E 17 November 2017 Copyright 2013, 2017 Hughes Network Systems, LLC All rights reserved. This publication

More information

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers /40 Nominal Input Voltage 120/277 Vac, 220 to 240 Vac Max. Output Power Nominal Output Voltage Max. Output Current 12, 24, 48 Vdc 5, 2.5, 1.25 A Efficiency up to 90% typical Max. Case Temperature 90 C

More information

Hughes 9450 Mobile Satellite Terminal. Installation Guide

Hughes 9450 Mobile Satellite Terminal. Installation Guide Hughes 9450 Mobile Satellite Terminal Installation Guide 3004129 Revision A September 15, 2010 Copyright 2010 Hughes Network Systems, LLC All rights reserved. This publication and its contents are proprietary

More information

F T 742 NEW TOUGHEST WIND SENSORS THE WORLD S

F T 742 NEW TOUGHEST WIND SENSORS THE WORLD S F T 7 2 2+ F T 742 D ATA S H E E T NEW D E S I G N E D F O R T U R B I N E C O N T R O L THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM PROVEN NEW LOOK, NEW SPEED, SAME STRENGTH The FT722 and

More information

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor Laboratory Grade Instruments 4020 Series & 4021 Power Meter Semiconductor 4020 SERIES Power Sensor 4021 4022 4024 4025 Power Input 300 mw to 1 kw 300 mw to 1 kw 3 W to 10 kw 3 W to 10 kw (1.2 kw max.)

More information

HexPort Multi-Band Antenna

HexPort Multi-Band Antenna DATA SHEET Six foot (1.8 m), six port antenna with a 65 azimuth beamwidth covering 698-894 MHz and 1710-2360 MHz frequencies Four high band and two low band ports including the WCS band in a single antenna

More information

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General

More information

Hybrid Bi-SectorTM Array

Hybrid Bi-SectorTM Array DATA SHEET Eight foot (2.4m), multiband, ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information