Intelligent Predictive Maintenance for Itapebi Hydro-Generator

Size: px
Start display at page:

Download "Intelligent Predictive Maintenance for Itapebi Hydro-Generator"

Transcription

1 Intelligent Predictive Maintenance for Itapebi Hydro-Generator LUIS CLAUDIO RIBEIRO, MARCO AURÉLIO M. GUTIERREZ, ELIAS G. DA SILVA Itapebi - Neoenergia Power Plant Co. Av. Edgar Santos, Bloco A4, 1º andar, Salvador, , BA BRAZIL {lribeiro, mgutierrez, LUIZ EDUARDO BORGES DA SILVA, ERIK L. BONALDI, LEVY ELY DE L. DE OLIVEIRA, JONAS GUEDES BORGES DA SILVA E GERMANO LAMBERT-TORRES CGTI Centro de Gestão de Tecnologia e Inovação R. dos Expedicionários, 1325, Campinas, , SP BRAZIL {leborgess, erik.bonaldi, levy.oliveira, jonas.borges, germanoltorres}@gmail.com Abstract: - This paper presents the development of a supervision system for predictive maintenance and diagnosis of hydro-generators. The aim of the developed system is to verify the degradation conditions of Itapebi generators. Initially, a system for extracting features of the hydro-generator operational database has been developed to detect possible problems that cause premature fails. The system has been divided in two parts. The first one is a data acquisition system directly connected to the generator in order to sample some operational variables. The second part concerns an intelligent data mining, into the database involving the supervision system variables, to use the existing historic data to perform analysis of the problems and possible causes. Key-Words: - Electrical measurements, maintenance, data mining, intelligent systems, hydro-generators. 1 Introduction The generators are the most important equipments in the energy generation process. The power system reliability, power system supply and power system stability are indexes directly affects for the generator operational conditions. For this reason, protection and monitoring equipment are increasingly employed in order to prevent fails.one of the technologies that can be employed within the purpose of predicting failures is the electric signature analysis (ESA) [1], which consists of a set of methods and techniques that monitor the condition of electric machines by identifying patterns and deviations. It is detected by processing and analysis of voltage and current signals acquired machinery under monitoring. These techniques based on electrical signatures can be applied from the generator and primary source until the motor and load coupled. They may be based on: (a) invasive methods, such as the electric circuit analysis (with static analysis and non-energized machine, also referred to as offline analysis and therefore invasive), or (b) non-invasive methods, such as ESA (dynamic analysis, i.e. with the machine in operation, also referred to as online analysis) [1].For a more comprehensive monitoring of the generator, it is important to the application of invasive and non-invasive methods, based not only on the signature electric as well as other monitoring techniques such as vibration analysis. It is recommended the application of invasive techniques in shutdowns, while non-invasive techniques should be applied periodically during the operating cycle of the machine. This project aims to develop a methodology for the detection and dynamic analyses of online monitoring of the condition of hydro-generators based on acquisition, processing and analysis of voltage and current signals. The main fails such as short-circuit in stator and rotor windings, fails in excitement system, misalignment and eccentricity of spinning field have been studied by electric signature analysis. The paper presents the developed system and some practical results in a Itapebi Power-Plant, located in Itapebi, northeast part of Brazil. ISBN:

2 2 Electric Signature Analysis Electric Signature Analysis (ESA) is the term used for all evaluations of voltage and current signals of electric machines. The most common analysis transforms the voltage and current signal to the frequency domain where they are analyzed. The analysis is based on two fundamental assumptions: (a) the signature of a machine with failure is different from the signature of a machine in perfect state of operation and (b) the failures are repeated with regular patterns, causing failure patterns, which can be identified and related parts of the machine. These techniques can be applied in electric motors and generators. It is important to note that the Voltage Signature Analysis (VSA) is related to an upstream analysis, i.e. toward the generator; and the Current Signature Analysis (CSA) is related to a downstream, i.e. toward the motor. In this project, CSA and the Extended Park Vector Approach (EPVA) are the methods used in this development because they have more features applicable to electric generators. Also these methods have been applied in electric motors, but not to generators yet. 2.1 Current and Voltage Signature Analysis CSA Current Signature Analysis or VSA Voltage Signature Analysis techniques are used to generate analyses and trend of electric machines dynamically. They aim to detect predictive problems in a rotating electric machine, such as: problems in the stator winding, rotor problems, problems on the engagement, problems in bound load, efficiency and system load; problems in the bearing, among others. It may initially cause a certain astonishment that the electrical signals contain information in addition to the electrical characteristics of the machine under supervision, but they work for mechanical defects as a transducer, allowing the electrical signals (voltage and/or current) can carry information of electrical and mechanical problems until the power panel of the machine. The signs of current and/or voltage of one or three phases of the machine produce, after analyzed, the signature of machine, i.e., its operating pattern. This signature is composed of magnitudes of frequencies of each individual component extracted from their signs of current or voltage. This fact isolated by itself is already a gain, as it allows the monitoring of the evolution of the magnitudes of the frequencies, which can denote some sort of evolution of operating conditions of the machinery. The response that the user of such a system needs to know is whether your machine is "healthy" or not, and that part of the machine the failure might occur. This analysis (diagnosis) is not something easy to be done, because it involves a set of comparisons with previously stored patterns and own "history" of the machine under analysis. In this instant, normally a specialist is called to produce the final diagnosis, generating the command when stopping the machine. Thus, the system developed in this project for automatic diagnosis that combines the history of turbo-generator, expert knowledge and failure patterns can be quite useful for the company. The Fast Fourier Transform (FFT) is the main tool employed, however some systems employ in conjunction with other techniques to increase the ability of fault detection signal from acquisition, through processing, to the diagnostic step. 2.2 Approach by Park Vector Extended The EPVA technique is used in the project mainly to check electrical stator imbalances, however it can be employed in the detection of other types of failure [1].The central idea of the technique is checking breakdowns by the distortion circle Park, that is, the more distorted the greater is the imbalance of electric machine. The current components of the vector Park are described by i D and i Q : i D 2 i 3 A 1 ib 6 1 ic 6 and i Q 1 ib 2 1 ic 2 Where the currents i A, i B and i C are the three phases. Ideally we have: 6 6 i D cos( ) 2 im t i Q ( ) 2 im sen t and ISBN:

3 To normal conditions, as shown in Fig. 1, the circle of the Park is centered at the origin of coordinates. (a) Fig. 1. Balanced signals: (a) signals in time and (b) circle of Park. (b) The circle Park passes to suffer distortions when there are abnormal conditions of operation or when failures of electrical or mechanical sources arise. However, these distortions in the circle of Park are not easy to be examined or measured, hence the proposition of the EPVA method extension, observing the spectrum of Park vector module. The EPVA technique combines the robustness analysis of circle of Park and the flexibility of spectral analysis [1]. An important point of this process is the transformation of Park causes a fundamental component of signals analyzed is withdrawn. This fact allows the components characteristics of failure to appear with greater prominence. And more, because it is a method that simultaneously covers the three phases, flaws that can only be detected through this joint analysis, such as the electric stator unbalance, are also covered by. 3 Electrical Signal Processing 3.1 Composition of the digital signal The purchasing system used makes the sampling of analog signals through an analog-to-digital converter (ADC). This way, an analog signal is sampled at a fixed rate for a fixed period and then stored and streamed to the analysis software. This way, each signal is encoded in a vector of integers, whose values represent its amplitude in different moments. Knowing of the transformation ratio of the sensor being used and the ADC input range, the software gets the signal amplitudes to current values in Amperes and voltage values in Volts. For example, assuming a current transformer ratio of transformation is of 100 mv/a and a sampling system of 16-bit input range ± 5V, a sign of 10 to be measured as a level 1 V on the input of the ADC and converted to an integer value If the entry is +5 V, this value would be or It is for the software to interpret these integer values, interpret them and reconstruct the signs of current and voltage. However, the signs used are now discrete (digital) and all the calculations and algorithms are employed the techniques of digital signal processing. 3.2 Conditioning and digital signal processing For the characteristic extraction of digital signals, there is a pre-conditioning process and then some paths to compute the values of each variable. Different parameters are obtained in the time domain and frequency domain. In Fig. 2, a flowchart of the used techniques is shown. The blocks with grey background represent a processed signal that can be viewed or used for the extraction of parameters or characteristics. The blocks represent a blank or algorithm applied to digital signal processing. The following is brief commentary of each of the processing blocks: Composition of signs: Converts data sent by the system of acquisition in digital signals whose amplitudes represent actual values of current and voltage. Preconditioning: process that eliminates the early part of the signal to avoid samples obtained during the transitional period of the filters. It is then eliminated the average value of each signal whose nature is toggled. Park Transformed: when there is a three-phase electrical system, comprising three strands (I A, I B and I C ) and three voltages (V AB, V BC and V CA ), applies the Park to get the vector of Park, consisting of the components I Q, I D ISBN:

4 and I 0. In some cases, it is also used the spectrum of the module of this vector to get the electric unbalance the system. Hilbert Transform: when applied to a signal, returns the magnitude (envelope) and instantaneous phase of the same. Filter RMS: knowing the fundamental frequency of the signal, the RMS filter returns the snapshot of the signal RMS value throughout the sampling period, resulting in the so-called RMS Curve. Windowing: filter applied to a signal in time to reduce the effect of "leakage" in the spectrum of frequencies of the same, due to process a signal with beginning and end. There are several types of windowing (Blackman, Hamming, Hanning, etc.). Fourier transform: used to transform a time domain signal into the frequency domain, the discrete Fourier transform (DFT) returns a vector of complex where obtained the spectral ranges and their corresponding stages. Fig. 2. Block diagram of the algorithms of signal conditioning and processing. In the process of windowing, was selected the Blackmann window. This window facilitates the identification of peaks, since it presents slightly wider lobes and lower "leakage" on their side bands than other Windows. To accelerate the achievement of the DFT, we used an algorithm called FFT (Fast Fourier Transform "). However, it is a requirement that the number of samples of the input signal is a power of 2. In the case where the acquired signals do not satisfy this rule, the technique of "zero-padding", or inclusion of zeros, fills the vector with null values until the number of samples is a power of 2. When the "zero-padding" is applied, proportional correction is made in the amplitudes of the spectrum of frequencies for which the true values are obtained. For example, in a signal with zeros are inserted samples to your end so that the signal has the total of samples, i.e samples. This technique can increase the spectral resolution, but it should be clear that there is more information than a spectrum obtained from a sign without the "zero-padding". 4 Description of the Data Mining Algorithm This section introduces expeditiously the data mining algorithm used to perform comparisons between the processed signals, the database signals and failures patterns. The used technique was based on the Rough Set Theory. This technique aims to extract a set of rules (or conditions) from a database through two hyper-sets, called upper approximation set and lower approximation set. The set of rules contains the lower approximation set and is contained by the upper approximation set. The central idea of the algorithm is to reduce the number of elements in the upper approximation set and to increase the number of elements in the lower approximation set. In an ideal condition, these two sets would become only one set that would be the required set. This set is ISBN:

5 represented by the set of production rules. The used algorithm has six main steps, they are: 1. initialization; 2. remove equal examples; 3. remove of dispensable attributes; 4. compute the core set; 5. compute the reduce set; and 6. merge rules. 5 Illustrative Example The Itapebi hydroelectric plant is operated by Itapebi Power Generation Co., which is a publicly traded corporation, controlled by holding Neoenergia Co.. It is located on the Rio Jequitinhonha Valley, in the currencies of the States of Bahia and Minas Gerais, Brazil. After an analysis of three generating units of 150 MW each, we opted to make this installation in the generator # 3, who would suffer a stop for scheduled maintenance within a few months. The plant began operating in Some Features about the Data Acquisition Figure 3 shows the layout of the installation monitoring system, while Fig. 4 shows how the system was actually installed in the Panel chosen. Fig. 3. Layout of data acquisition system. Fig. 4. Photo of the installation of data acquisition System. The monitoring system makes their analysis based on an analysis of current and voltage signals measured from hydro-generator. Each measurement is called "acquisition" and contains one or more current and voltage signals sampled from hydro-generator, via data acquisition device. The time of each acquisition is determined by the sampling frequency and number of samples that the user has defined. The analysis of acquisitions is an important step in the verification and confirmation of fault diagnostics issued by the system. Through dialogue of analysis, you can view the current and voltage signals acquired and their signatures (VSA, CSA, EPVA), all in a friendly and easy to use. Presented in graphical form and organized into "tabs", the analysis Dialog allows the user to show parameters and failure patterns extracted from the acquisition. It has five views, organized in tabs above. They are: Sign in time: shows the signs of current and voltage at the time, such which were sampled. In the upper right is shown the phasorial diagram of the electrical system-phase related to the measured signals; CSA + VSA: in this view are shown signs of current and voltage in the frequency domain. Through the analysis of the current signature (VSA) and voltage (VSA), allows the user to show various patterns of hydrogenerator failures; EPVA: exposes the vector of Park of current and voltage of the system through graphics module of vector Park and Park circle. Possesses diagnostic aid standards analysis EPVA; ISBN:

6 5.2 Computational Package The developed computational package is composed to two main parts: (a) data acquisition control and (b) feature extraction and signal processing. The first part contains parameters for data acquisition process. Special window interfaces have been developed to transfer all system control to the operator. Examples of this interface are shown in Fig. 5. These interfaces are in Portuguese language. The first figure shows an example of the supervision interface with the data acquisition control information; and the second figure is one of the analysis procedures. As illustrated in Figure 5a, the supervisory dialog is organized through the following regions: Header: top that indicates the handle of hydro-generator, your general condition and the condition of the parties which compose it. The general condition is represented by the circle in the right part of the identifier; Trends: central part of the dialogue that allows monitoring of key parameters and patterns of failure through trend curves; Acquisition: located at the bottom, allows the user to control how measurements are made. Furthermore, it allows presents a description of recent acquisitions and the history of attempts to purchase. Figure 5b illustrates the messages of the history of attempts to purchase. Through this history it is possible to identify problems with the purchasing system. (a) (b) Fig. 5. (a) Supervisory dialog screen and (b) Supervisory dialog screen-purchase history (interfaces in Portuguese language). 6 Conclusions This paper shows a complete development of a supervision system with an intelligent data signal processing based on feature extraction using Rough Set Theory. The feature extraction relates processed current and voltage signals from the hydro-generator by VSA, CSA and EPVA techniques, hydro-generator electrical and mechanical parameters, and typical types of failures existing in this kind of machine. Hardware and software have been developed to acquire and treat the electrical signals in a non-invasive process. It means, the operational condition of the generator is verified without any type of disturbance in the machine or in its control. The electrical signals are taken out of the machine, more specifically in the secondary of instrument transformers (CT and PT) in the panel control. This system is currently in full operation at Itapebi Power Plant, in Brazil. Reference: 1. Bonaldi, E.L.: Failure Predictive Diagnostic in Three-Phase Induction Motors with MCSA and Rough Set Theory. Ph.D. Thesis, Itajuba Federal School of Engineering, Itajuba Brazil (2006) - in Portuguese. ISBN:

Capacitive MEMS accelerometer for condition monitoring

Capacitive MEMS accelerometer for condition monitoring Capacitive MEMS accelerometer for condition monitoring Alessandra Di Pietro, Giuseppe Rotondo, Alessandro Faulisi. STMicroelectronics 1. Introduction Predictive maintenance (PdM) is a key component of

More information

Application of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

Application of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Application of Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Introduction Over the past months we have covered traditional and modern methods of testing electric

More information

Vibration based condition monitoring of rotating machinery

Vibration based condition monitoring of rotating machinery Vibration based condition monitoring of rotating machinery Goutam Senapaty 1* and Sathish Rao U. 1 1 Department of Mechanical and Manufacturing Engineering, Manipal Institute of Technology, Manipal Academy

More information

D DAVID PUBLISHING. 1. Introduction

D DAVID PUBLISHING. 1. Introduction Journal of Mechanics Engineering and Automation 5 (2015) 286-290 doi: 10.17265/2159-5275/2015.05.003 D DAVID PUBLISHING Classification of Ultrasonic Signs Pre-processed by Fourier Transform through Artificial

More information

A Methodology for Testing of Substation Functional Circuits

A Methodology for Testing of Substation Functional Circuits A Methodology for Testing of Substation Functional Circuits GERMANO LAMBERT-TORRES CARLOS HENRIQUE VALÉRIO DE MORAES LUIZ EDUARDO BORGES DA SILVA JAMIL HADDAD Itajubá Federal University Av. BPS, 1303 Pinheirinho

More information

Electrical Machines Diagnosis

Electrical Machines Diagnosis Monitoring and diagnosing faults in electrical machines is a scientific and economic issue which is motivated by objectives for reliability and serviceability in electrical drives. This concern for continuity

More information

Appearance of wear particles. Time. Figure 1 Lead times to failure offered by various conventional CM techniques.

Appearance of wear particles. Time. Figure 1 Lead times to failure offered by various conventional CM techniques. Vibration Monitoring: Abstract An earlier article by the same authors, published in the July 2013 issue, described the development of a condition monitoring system for the machinery in a coal workshop

More information

Wireless Health Monitoring System for Vibration Detection of Induction Motors

Wireless Health Monitoring System for Vibration Detection of Induction Motors Page 1 of 6 Wireless Health Monitoring System for Vibration Detection of Induction Motors Suratsavadee Korkua 1 Himanshu Jain 1 Wei-Jen Lee 1 Chiman Kwan 2 Student Member, IEEE Fellow, IEEE Member, IEEE

More information

Vibration and Current Monitoring for Fault s Diagnosis of Induction Motors

Vibration and Current Monitoring for Fault s Diagnosis of Induction Motors Vibration and Current Monitoring for Fault s Diagnosis of Induction Motors Mariana IORGULESCU, Robert BELOIU University of Pitesti, Electrical Engineering Departament, Pitesti, ROMANIA iorgulescumariana@mail.com

More information

Classification of Misalignment and Unbalance Faults Based on Vibration analysis and KNN Classifier

Classification of Misalignment and Unbalance Faults Based on Vibration analysis and KNN Classifier Classification of Misalignment and Unbalance Faults Based on Vibration analysis and KNN Classifier Ashkan Nejadpak, Student Member, IEEE, Cai Xia Yang*, Member, IEEE Mechanical Engineering Department,

More information

Condition Monitoring of Rotationg Equpiment s using Vibration Signature Analysis- A Review

Condition Monitoring of Rotationg Equpiment s using Vibration Signature Analysis- A Review Condition Monitoring of Rotationg Equpiment s using Vibration Signature Analysis- A Review Murgayya S B, Assistant Professor, Department of Automobile Engineering, DSCE, Bangalore Dr. H.N Suresh, Professor

More information

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses Spectra Quest, Inc. 8205 Hermitage Road, Richmond, VA 23228, USA Tel: (804) 261-3300 www.spectraquest.com October 2006 ABSTRACT

More information

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance: ETP SYSTEM Condition-based maintenance of power transformers The predictive and condition based maintenance is nowadays accepted as the most efficient solution to guarantee the proper operation of critical

More information

Application Note. GE Grid Solutions. Multilin 8 Series 869 Broken Rotor Bar Detection. Introduction

Application Note. GE Grid Solutions. Multilin 8 Series 869 Broken Rotor Bar Detection. Introduction GE Grid Solutions Multilin 8 Series 869 Broken Rotor Bar Detection Application Note GE Publication Number: GET-20061 Copyright 2018 GE Multilin Inc. Introduction The Multilin 869 motor protection relay

More information

MCSA and SVM for gear wear monitoring in lifting cranes

MCSA and SVM for gear wear monitoring in lifting cranes MCSA and SVM for gear wear monitoring in lifting cranes Raymond Ghandour 1, Fahed Abdallah 1 and Mario Eltabach 2 1 Laboratoire HEUDIASYC, UMR CNRS 7253, Université de Technologie de Compiègne, Centre

More information

Fault Detection in Three Phase Induction Motor

Fault Detection in Three Phase Induction Motor Fault Detection in Three Phase Induction Motor A.Selvanayakam 1, W.Rajan Babu 2, S.K.Rajarathna 3 Final year PG student, Department of Electrical and Electronics Engineering, Sri Eshwar College of Engineering,

More information

FAULT DIAGNOSIS AND PERFORMANCE ASSESSMENT FOR A ROTARY ACTUATOR BASED ON NEURAL NETWORK OBSERVER

FAULT DIAGNOSIS AND PERFORMANCE ASSESSMENT FOR A ROTARY ACTUATOR BASED ON NEURAL NETWORK OBSERVER 7 Journal of Marine Science and Technology, Vol., No., pp. 7-78 () DOI:.9/JMST-3 FAULT DIAGNOSIS AND PERFORMANCE ASSESSMENT FOR A ROTARY ACTUATOR BASED ON NEURAL NETWORK OBSERVER Jian Ma,, Xin Li,, Chen

More information

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM L.Kanimozhi 1, Manimaran.R 2, T.Rajeshwaran 3, Surijith Bharathi.S 4 1,2,3,4 Department of Mechatronics Engineering, SNS College Technology, Coimbatore,

More information

Shaft Vibration Monitoring System for Rotating Machinery

Shaft Vibration Monitoring System for Rotating Machinery 2016 Sixth International Conference on Instrumentation & Measurement, Computer, Communication and Control Shaft Vibration Monitoring System for Rotating Machinery Zhang Guanglin School of Automation department,

More information

Wavelet Transform for Bearing Faults Diagnosis

Wavelet Transform for Bearing Faults Diagnosis Wavelet Transform for Bearing Faults Diagnosis H. Bendjama and S. Bouhouche Welding and NDT research centre (CSC) Cheraga, Algeria hocine_bendjama@yahoo.fr A.k. Moussaoui Laboratory of electrical engineering

More information

MOTORS FAULT RECOGNITION USING DISTRIBUTED CURRENT SIGNATURE ANALYSIS. Alireza Gheitasi

MOTORS FAULT RECOGNITION USING DISTRIBUTED CURRENT SIGNATURE ANALYSIS. Alireza Gheitasi MOTORS FAULT RECOGNITION USING DISTRIBUTED CURRENT SIGNATURE ANALYSIS Alireza Gheitasi A thesis submitted to Auckland University of Technology in fulfilment of the requirements for the degree of Doctor

More information

Developer Techniques Sessions

Developer Techniques Sessions 1 Developer Techniques Sessions Physical Measurements and Signal Processing Control Systems Logging and Networking 2 Abstract This session covers the technologies and configuration of a physical measurement

More information

Influence of Vibration of Tail Platform of Hydropower Station on Transformer Performance

Influence of Vibration of Tail Platform of Hydropower Station on Transformer Performance Influence of Vibration of Tail Platform of Hydropower Station on Transformer Performance Hao Liu a, Qian Zhang b School of Mechanical and Electronic Engineering, Shandong University of Science and Technology,

More information

NON-INVASIVE ROTOR BAR FAULTS DIAGNOSIS OF INDUCTION MACHINES USING VIRTUAL INSTRUMENTATION

NON-INVASIVE ROTOR BAR FAULTS DIAGNOSIS OF INDUCTION MACHINES USING VIRTUAL INSTRUMENTATION NON-INVASIVE ROTOR BAR FAULTS DIAGNOSIS OF INDUCTION MACHINES USING VIRTUAL INSTRUMENTATION Loránd SZABÓ Károly Ágoston BIRÓ Jenő Barna DOBAI Technical University of Cluj (Romania) 3400 Cluj, P.O. Box

More information

Current-Based Online Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Spectrum Analysis and Impulse Detection

Current-Based Online Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Spectrum Analysis and Impulse Detection Current-Based Online Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Spectrum Analysis and Impulse Detection Xiang Gong, Member, IEEE, and Wei Qiao, Member, IEEE Abstract--Online fault diagnosis

More information

3500/46M Hydro Monitor

3500/46M Hydro Monitor 3500/46M Hydro Monitor Smart Monitoring for the Intelligent Machine Age Mark Snyder Bently Nevada Senior Field Application Engineer mark.snyder@ge.com Older machinery protection systems, and even transmitters

More information

Stator Winding Fault in Induction Motor

Stator Winding Fault in Induction Motor Chapter 7 Stator Winding Fault in Induction Motor Chapter Outline Stator is one of the major fault areas in an induction motor. Stator fault initiates as a turn to turn short fault of its winding which

More information

Application Note. GE Grid Solutions. Multilin 8 Series Applying Electrical Signature Analysis in 869 for Motor M&D. Overview.

Application Note. GE Grid Solutions. Multilin 8 Series Applying Electrical Signature Analysis in 869 for Motor M&D. Overview. GE Grid Solutions Multilin 8 Series Applying Electrical Signature Analysis in 869 for Motor M&D Application Note GE Publication Number: GET-20060 Copyright 2018 GE Multilin Inc. Overview Motors play a

More information

A NEW MOTOR SPEED MEASUREMENT ALGORITHM BASED ON ACCURATE SLOT HARMONIC SPECTRAL ANALYSIS

A NEW MOTOR SPEED MEASUREMENT ALGORITHM BASED ON ACCURATE SLOT HARMONIC SPECTRAL ANALYSIS A NEW MOTOR SPEED MEASUREMENT ALGORITHM BASED ON ACCURATE SLOT HARMONIC SPECTRAL ANALYSIS M. Aiello, A. Cataliotti, S. Nuccio Dipartimento di Ingegneria Elettrica -Università degli Studi di Palermo Viale

More information

ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS

ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS SZABÓ Loránd DOBAI Jenő Barna BIRÓ Károly Ágoston Technical University of Cluj (Romania) 400750 Cluj, P.O. Box 358,

More information

VIBRATION ANALYZER. Vibration Analyzer VA-12

VIBRATION ANALYZER. Vibration Analyzer VA-12 VIBRATION ANALYZER Vibration Analyzer VA-12 Portable vibration analyzer for Equipment Diagnosis and On-site Measurements Vibration Meter VA-12 With FFT analysis function Piezoelectric Accelerometer PV-57with

More information

SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS

SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS Page 1 of 10 2015-PPIC-0187 SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS Ian Culbert Senior Member, IEEE Qualitrol-Iris Power 3110 American Drive Mississauga, ON Canada Abstract - Stator current signature

More information

ZOOM Software Measurement and Graph Types

ZOOM Software Measurement and Graph Types ZOOM Software Measurement and Graph Types AN002 The ZOOM software operates under two measurement modes: Automatic and Test. The Automatic mode records data automatically at user-defined intervals or alarm

More information

Bearing fault detection of wind turbine using vibration and SPM

Bearing fault detection of wind turbine using vibration and SPM Bearing fault detection of wind turbine using vibration and SPM Ruifeng Yang 1, Jianshe Kang 2 Mechanical Engineering College, Shijiazhuang, China 1 Corresponding author E-mail: 1 rfyangphm@163.com, 2

More information

Rotating Machinery Analysis

Rotating Machinery Analysis Rotating Machinery Analysis m+p Analyzer provides a complete package of data acquisition and analysis tools for capturing and understanding noise and vibration induced in rotating and reciprocating machines

More information

Stator Fault Detector for AC Motors Based on the TMS320F243 DSP Controller

Stator Fault Detector for AC Motors Based on the TMS320F243 DSP Controller Stator Fault Detector for AC Motors Based on the TMS320F243 DSP Controller Bin Huo and Andrzej M. Trzynadlowski University of Nevada, Electrical Engineering Department/260, Reno, NV 89557-0153 Ph. (775)

More information

Artesis Predictive Maintenance Revolution

Artesis Predictive Maintenance Revolution Artesis Predictive Maintenance Revolution September 2008 1. Background Although the benefits of predictive maintenance are widely accepted, the proportion of companies taking full advantage of the approach

More information

User-friendly Matlab tool for easy ADC testing

User-friendly Matlab tool for easy ADC testing User-friendly Matlab tool for easy ADC testing Tamás Virosztek, István Kollár Budapest University of Technology and Economics, Department of Measurement and Information Systems Budapest, Hungary, H-1521,

More information

Methodology for Localizing Additive Upstream Impairments on CATV Networks

Methodology for Localizing Additive Upstream Impairments on CATV Networks 60288 INVENTION DISCLOSURE 1. Invention Title. Methodology for Localizing Additive Upstream Impairments on CATV Networks 2. Invention Summary. This invention disclosure, defines a methodology to localize

More information

VIBRATIONAL MEASUREMENT ANALYSIS OF FAULT LATENT ON A GEAR TOOTH

VIBRATIONAL MEASUREMENT ANALYSIS OF FAULT LATENT ON A GEAR TOOTH VIBRATIONAL MEASUREMENT ANALYSIS OF FAULT LATENT ON A GEAR TOOTH J.Sharmila Devi 1, Assistant Professor, Dr.P.Balasubramanian 2, Professor 1 Department of Instrumentation and Control Engineering, 2 Department

More information

Practical Machinery Vibration Analysis and Predictive Maintenance

Practical Machinery Vibration Analysis and Predictive Maintenance Practical Machinery Vibration Analysis and Predictive Maintenance By Steve Mackay Dean of Engineering Engineering Institute of Technology EIT Micro-Course Series Every two weeks we present a 35 to 45 minute

More information

A Novel Approach to Electrical Signature Analysis

A Novel Approach to Electrical Signature Analysis A Novel Approach to Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP Vice President, Engineering and Reliability Services Dreisilker Electric Motors, Inc. Abstract: Electrical Signature Analysis

More information

Beating Phenomenon of Multi-Harmonics Defect Frequencies in a Rolling Element Bearing: Case Study from Water Pumping Station

Beating Phenomenon of Multi-Harmonics Defect Frequencies in a Rolling Element Bearing: Case Study from Water Pumping Station Beating Phenomenon of Multi-Harmonics Defect Frequencies in a Rolling Element Bearing: Case Study from Water Pumping Station Fathi N. Mayoof Abstract Rolling element bearings are widely used in industry,

More information

Detection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio

Detection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio Wind energy resource assessment and forecasting Detection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio J. Hanna Lead Engineer/Technologist jesse.hanna@ge.com C. Hatch Principal Engineer/Technologist

More information

Early Failure Detection in Power Transformers

Early Failure Detection in Power Transformers Journal of Power and Energy Engineering, 2013, 1, 30-40 http://dx.doi.org/10.4236/jpee.2013.15005 Published Online October 2013 (http://www.scirp.org/journal/jpee) Luiz Eduardo Borges da Silva 1, Erik

More information

Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor

Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor 19 th World Conference on Non-Destructive Testing 2016 Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor Leon SWEDROWSKI 1, Tomasz CISZEWSKI 1, Len GELMAN 2

More information

ME scope Application Note 01 The FFT, Leakage, and Windowing

ME scope Application Note 01 The FFT, Leakage, and Windowing INTRODUCTION ME scope Application Note 01 The FFT, Leakage, and Windowing NOTE: The steps in this Application Note can be duplicated using any Package that includes the VES-3600 Advanced Signal Processing

More information

Latest Control Technology in Inverters and Servo Systems

Latest Control Technology in Inverters and Servo Systems Latest Control Technology in Inverters and Servo Systems Takao Yanase Hidetoshi Umida Takashi Aihara. Introduction Inverters and servo systems have achieved small size and high performance through the

More information

CHAPTER 6. CALCULATION OF TUNING PARAMETERS FOR VIBRATION CONTROL USING LabVIEW

CHAPTER 6. CALCULATION OF TUNING PARAMETERS FOR VIBRATION CONTROL USING LabVIEW 130 CHAPTER 6 CALCULATION OF TUNING PARAMETERS FOR VIBRATION CONTROL USING LabVIEW 6.1 INTRODUCTION Vibration control of rotating machinery is tougher and a challenging challengerical technical problem.

More information

Partial Discharge Monitoring and Diagnosis of Power Generator

Partial Discharge Monitoring and Diagnosis of Power Generator Partial Discharge Monitoring and Diagnosis of Power Generator Gao Wensheng Institute of High Voltage & insulation tech. Electrical Eng. Dept., Tsinghua University Wsgao@tsinghua.edu.cn Currently preventive

More information

Swinburne Research Bank

Swinburne Research Bank Swinburne Research Bank http://researchbank.swinburne.edu.au Tashakori, A., & Ektesabi, M. (2013). A simple fault tolerant control system for Hall Effect sensors failure of BLDC motor. Originally published

More information

Discrete Fourier Transform (DFT)

Discrete Fourier Transform (DFT) Amplitude Amplitude Discrete Fourier Transform (DFT) DFT transforms the time domain signal samples to the frequency domain components. DFT Signal Spectrum Time Frequency DFT is often used to do frequency

More information

Analysis of Wound Rotor Induction Machine Low Frequency Vibroacoustic Emissions under Stator Winding Fault Conditions

Analysis of Wound Rotor Induction Machine Low Frequency Vibroacoustic Emissions under Stator Winding Fault Conditions Analysis of Wound Rotor Induction Machine Low Frequency Vibroacoustic Emissions under Stator Winding Fault Conditions N Sarma, Q Li, S. Djurović, A C Smith, S M Rowland University of Manchester, School

More information

FAULT DETECTION IN DEEP GROOVE BALL BEARING USING FFT ANALYZER

FAULT DETECTION IN DEEP GROOVE BALL BEARING USING FFT ANALYZER FAULT DETECTION IN DEEP GROOVE BALL BEARING USING FFT ANALYZER Sushmita Dudhade 1, Shital Godage 2, Vikram Talekar 3 Akshay Vaidya 4, Prof. N.S. Jagtap 5 1,2,3,4, UG students SRES College of engineering,

More information

Prognostic Health Monitoring for Wind Turbines

Prognostic Health Monitoring for Wind Turbines Prognostic Health Monitoring for Wind Turbines Wei Qiao, Ph.D. Director, Power and Energy Systems Laboratory Associate Professor, Department of ECE University of Nebraska Lincoln Lincoln, NE 68588-511

More information

Time- Frequency Techniques for Fault Identification of Induction Motor

Time- Frequency Techniques for Fault Identification of Induction Motor International Journal of Electronic Networks Devices and Fields. ISSN 0974-2182 Volume 8 Number 1 (2016) pp. 13-17 International Research Publication House http://www.irphouse.com Time- Frequency Techniques

More information

m+p Analyzer Revision 5.2

m+p Analyzer Revision 5.2 Update Note www.mpihome.com m+p Analyzer Revision 5.2 Enhanced Project Browser New Acquisition Configuration Windows Improved 2D Chart Reference Traces in 2D Single- and Multi-Chart Template Projects Trigger

More information

Pioneering Partnership Performance

Pioneering Partnership Performance Pioneering Partnership Performance Born for In-Field Testing Impaq Elite is a portable 4 channel real-time analyzer that is built for advanced noise and vibration test in the field. Unique features like

More information

PeakVue Analysis for Antifriction Bearing Fault Detection

PeakVue Analysis for Antifriction Bearing Fault Detection Machinery Health PeakVue Analysis for Antifriction Bearing Fault Detection Peak values (PeakVue) are observed over sequential discrete time intervals, captured, and analyzed. The analyses are the (a) peak

More information

VOLD-KALMAN ORDER TRACKING FILTERING IN ROTATING MACHINERY

VOLD-KALMAN ORDER TRACKING FILTERING IN ROTATING MACHINERY TŮMA, J. GEARBOX NOISE AND VIBRATION TESTING. IN 5 TH SCHOOL ON NOISE AND VIBRATION CONTROL METHODS, KRYNICA, POLAND. 1 ST ED. KRAKOW : AGH, MAY 23-26, 2001. PP. 143-146. ISBN 80-7099-510-6. VOLD-KALMAN

More information

INDEX. PdMA PRODUCT SUPPORT MANUAL

INDEX. PdMA PRODUCT SUPPORT MANUAL % Current Imbalance, 6-58, 6-63 % FLA, 6-62 % Full Load Amps, 6-58, 6-62, 6-74 % Slip, 6-57 A About, 3-16 Absorption Current, 5-64 AC Assets, 7-14 AC EMAX Summary Report, 3-46 AC Induction, 5-7 Analysis,

More information

Review on Fault Identification and Diagnosis of Gear Pair by Experimental Vibration Analysis

Review on Fault Identification and Diagnosis of Gear Pair by Experimental Vibration Analysis Review on Fault Identification and Diagnosis of Gear Pair by Experimental Vibration Analysis 1 Ajanalkar S. S., 2 Prof. Shrigandhi G. D. 1 Post Graduate Student, 2 Assistant Professor Mechanical Engineering

More information

Prediction of Defects in Roller Bearings Using Vibration Signal Analysis

Prediction of Defects in Roller Bearings Using Vibration Signal Analysis World Applied Sciences Journal 4 (1): 150-154, 2008 ISSN 1818-4952 IDOSI Publications, 2008 Prediction of Defects in Roller Bearings Using Vibration Signal Analysis H. Mohamadi Monavar, H. Ahmadi and S.S.

More information

Of interest in the bearing diagnosis are the occurrence frequency and amplitude of such oscillations.

Of interest in the bearing diagnosis are the occurrence frequency and amplitude of such oscillations. BEARING DIAGNOSIS Enveloping is one of the most utilized methods to diagnose bearings. This technique is based on the constructive characteristics of the bearings and is able to find shocks and friction

More information

How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring. Chunhua Yang

How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring. Chunhua Yang 4th International Conference on Mechatronics, Materials, Chemistry and Computer Engineering (ICMMCCE 205) How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring

More information

Chapter 4 SPEECH ENHANCEMENT

Chapter 4 SPEECH ENHANCEMENT 44 Chapter 4 SPEECH ENHANCEMENT 4.1 INTRODUCTION: Enhancement is defined as improvement in the value or Quality of something. Speech enhancement is defined as the improvement in intelligibility and/or

More information

UNIT-4 POWER QUALITY MONITORING

UNIT-4 POWER QUALITY MONITORING UNIT-4 POWER QUALITY MONITORING Terms and Definitions Spectrum analyzer Swept heterodyne technique FFT (or) digital technique tracking generator harmonic analyzer An instrument used for the analysis and

More information

ANSE VISUAL, developed within the

ANSE VISUAL, developed within the ANSE VISUAL Software to Analyze Substation Robustness ANSE VISUAL, developed within the Institutional Project 1724, is a tool to analyze the robustness of electrical substations. The software carries out

More information

The Multi-Technology Approach to Motor Diagnostics

The Multi-Technology Approach to Motor Diagnostics The Multi-Technology Approach to Motor Diagnostics Howard W. Penrose, Ph.D. For: ALL-TEST Pro Old Saybrook, CT Introduction There has been a persistent misconception that there is a magic bullet, in the

More information

PERMANENT magnet brushless DC motors have been

PERMANENT magnet brushless DC motors have been Inverter Switch Fault Diagnosis System for BLDC Motor Drives A. Tashakori and M. Ektesabi Abstract Safe operation of electric motor drives is of prime research interest in various industrial applications.

More information

Vibration Analysis of Induction Motors with Unbalanced Loads

Vibration Analysis of Induction Motors with Unbalanced Loads Vibration Analysis of Induction Motors with Unbalanced Loads Selahattin GÜÇLÜ 1, Abdurrahman ÜNSAL 1 and Mehmet Ali EBEOĞLU 1 1 Dumlupinar University, Department of Electrical Engineering, Tavşanlı Yolu,

More information

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM Anna Tjäder Chalmers University of Technology anna.tjader@chalmers.se Math Bollen Luleå University of Technology math.bollen@stri.se ABSTRACT Power

More information

VIBRATION ANALYZER. Vibration Analyzer VA-12

VIBRATION ANALYZER. Vibration Analyzer VA-12 VIBRATION ANALYZER Vibration Analyzer VA-12 Portable vibration analyzer for Equipment Diagnosis and On-site Measurements Vibration Meter VA-12 With FFT analysis function Piezoelectric Accelerometer PV-57with

More information

Acceleration Enveloping Higher Sensitivity, Earlier Detection

Acceleration Enveloping Higher Sensitivity, Earlier Detection Acceleration Enveloping Higher Sensitivity, Earlier Detection Nathan Weller Senior Engineer GE Energy e-mail: nathan.weller@ps.ge.com Enveloping is a tool that can give more information about the life

More information

Diagnostics of Bearing Defects Using Vibration Signal

Diagnostics of Bearing Defects Using Vibration Signal Diagnostics of Bearing Defects Using Vibration Signal Kayode Oyeniyi Oyedoja Abstract Current trend toward industrial automation requires the replacement of supervision and monitoring roles traditionally

More information

Current-Based Diagnosis for Gear Tooth Breaks in Wind Turbine Gearboxes

Current-Based Diagnosis for Gear Tooth Breaks in Wind Turbine Gearboxes Current-Based Diagnosis for Gear Tooth Breaks in Wind Turbine Gearboxes Dingguo Lu Student Member, IEEE Department of Electrical Engineering University of Nebraska-Lincoln Lincoln, NE 68588-5 USA Stan86@huskers.unl.edu

More information

Broken Rotor Bar Fault Detection using Wavlet

Broken Rotor Bar Fault Detection using Wavlet Broken Rotor Bar Fault Detection using Wavlet sonalika mohanty Department of Electronics and Communication Engineering KISD, Bhubaneswar, Odisha, India Prof.(Dr.) Subrat Kumar Mohanty, Principal CEB Department

More information

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada Abstract Flux monitoring via permanently installed air gap

More information

Design and Implementation of ZigBee based Vibration Monitoring and Analysis for Electrical Machines

Design and Implementation of ZigBee based Vibration Monitoring and Analysis for Electrical Machines Design and Implementation of ZigBee based Vibration Monitoring and Analysis for Electrical Machines Suratsavadee K. Korkua 1 Wei-Jen Lee 1 Chiman Kwan 2 Student Member, IEEE Fellow, IEEE Member, IEEE 1.

More information

1 INTRODUCTION 2 MODELLING AND EXPERIMENTAL TOOLS

1 INTRODUCTION 2 MODELLING AND EXPERIMENTAL TOOLS Investigation of Harmonic Emissions in Wound Rotor Induction Machines K. Tshiloz, D.S. Vilchis-Rodriguez, S. Djurović The University of Manchester, School of Electrical and Electronic Engineering, Power

More information

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability Marc Langevin, eng., Ph.D.*. Marc Soullière, tech.** Jean Bélanger, eng.***

More information

An observation on non-linear behaviour in condition monitoring

An observation on non-linear behaviour in condition monitoring การประช มเคร อข ายว ศวกรรมเคร องกลแห งประเทศไทยคร งท 18 18-20 ต ลาคม 2547 จ งหว ดขอนแก น An observation on non-linear behaviour in condition monitoring Apirak Jiewchaloemmit 1, Janewith Luangcharoenkij

More information

Introduction. Chapter Time-Varying Signals

Introduction. Chapter Time-Varying Signals Chapter 1 1.1 Time-Varying Signals Time-varying signals are commonly observed in the laboratory as well as many other applied settings. Consider, for example, the voltage level that is present at a specific

More information

DETECTION THE CONDITION OF A FAN TRANSMISSION IN METAL SMELTER FENI KAVADARCI USING VIBRATION SIGNATURE

DETECTION THE CONDITION OF A FAN TRANSMISSION IN METAL SMELTER FENI KAVADARCI USING VIBRATION SIGNATURE DETECTION THE CONDITION OF A FAN TRANSMISSION IN METAL SMELTER FENI KAVADARCI USING VIBRATION SIGNATURE Prof. Geramitchioski T. PhD. 1, Doc.Trajcevski Lj. PhD. 1, Prof. Mitrevski V. PhD. 1, Doc.Vilos I.

More information

Time-Frequency Enhancement Technique for Bevel Gear Fault Diagnosis

Time-Frequency Enhancement Technique for Bevel Gear Fault Diagnosis Time-Frequency Enhancement Technique for Bevel Gear Fault Diagnosis Dennis Hartono 1, Dunant Halim 1, Achmad Widodo 2 and Gethin Wyn Roberts 3 1 Department of Mechanical, Materials and Manufacturing Engineering,

More information

Characterization of Train-Track Interactions based on Axle Box Acceleration Measurements for Normal Track and Turnout Passages

Characterization of Train-Track Interactions based on Axle Box Acceleration Measurements for Normal Track and Turnout Passages Porto, Portugal, 30 June - 2 July 2014 A. Cunha, E. Caetano, P. Ribeiro, G. Müller (eds.) ISSN: 2311-9020; ISBN: 978-972-752-165-4 Characterization of Train-Track Interactions based on Axle Box Acceleration

More information

Power Quality Measurements Embedded in Smart Lighting Systems

Power Quality Measurements Embedded in Smart Lighting Systems Power Quality Measurements Embedded in Smart Lighting Systems Milena F. Pinto, Thiago R. F. Mendonça, Carlos A. Duque and Henrique A. C. Braga Federal University of Juiz de Fora UFJF Juiz de Fora, MG Brazil

More information

Vibration Monitoring for Defect Diagnosis on a Machine Tool: A Comprehensive Case Study

Vibration Monitoring for Defect Diagnosis on a Machine Tool: A Comprehensive Case Study Vibration Monitoring for Defect Diagnosis on a Machine Tool: A Comprehensive Case Study Mouleeswaran Senthilkumar, Moorthy Vikram and Bhaskaran Pradeep Department of Production Engineering, PSG College

More information

Research Article High Frequency Acceleration Envelope Power Spectrum for Fault Diagnosis on Journal Bearing using DEWESOFT

Research Article High Frequency Acceleration Envelope Power Spectrum for Fault Diagnosis on Journal Bearing using DEWESOFT Research Journal of Applied Sciences, Engineering and Technology 8(10): 1225-1238, 2014 DOI:10.19026/rjaset.8.1088 ISSN: 2040-7459; e-issn: 2040-7467 2014 Maxwell Scientific Publication Corp. Submitted:

More information

Analysis and Modeling of a Platform with Cantilever Beam using SMA Actuator Experimental Tests based on Computer Supported Education

Analysis and Modeling of a Platform with Cantilever Beam using SMA Actuator Experimental Tests based on Computer Supported Education Analysis and Modeling of a Platform with Cantilever Beam using SMA Actuator Experimental Tests based on Computer Supported Education Leandro Maciel Rodrigues 1, Thamiles Rodrigues de Melo¹, Jaidilson Jó

More information

Generalised spectral norms a method for automatic condition monitoring

Generalised spectral norms a method for automatic condition monitoring Generalised spectral norms a method for automatic condition monitoring Konsta Karioja Mechatronics and machine diagnostics research group, Faculty of technology, P.O. Box 42, FI-914 University of Oulu,

More information

Condition Monitoring and Vibrational Analysis of Shaft Through Experimental and FEA Approach

Condition Monitoring and Vibrational Analysis of Shaft Through Experimental and FEA Approach ISSN 2395-1621 Condition Monitoring and Vibrational Analysis of Shaft Through Experimental and FEA Approach #1 Prajakta M Patil, #2 Ashish U Gandigude 1 praj.patil91@gmail.com 2 ashish.gandigude@zealeducation.com

More information

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery Application of EMI Diagnostics to Hydro Generators James Timperley Doble Global Power Services Columbus, Ohio jtimperley@doble.com

More information

Journal of Engineering Technology

Journal of Engineering Technology A novel mitigation algorithm for switch open-fault in parallel inverter topology fed induction motor drive M. Dilip *a, S. F. Kodad *b B. Sarvesh *c a Department of Electrical and Electronics Engineering,

More information

Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2

Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2 Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2 1 Dept. Of Electrical and Electronics, Sree Buddha College of Engineering 2

More information

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses* IntroductiontoMachineryVibrationSheetAnswer Chapter1:VibrationsSourcesandUses 1. 1. imposed motions related to the function - e.g. slider crank and earn 2. inadequate design - e.g. resonance 3. manufacturing

More information

Vibration Analysis on Rotating Shaft using MATLAB

Vibration Analysis on Rotating Shaft using MATLAB IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 06 December 2016 ISSN (online): 2349-784X Vibration Analysis on Rotating Shaft using MATLAB K. Gopinath S. Periyasamy PG

More information

Credit: 1 PDH. Course Title: Bearing Fault Detection in Induction Machine Using Squared Envelope Analysis of Stator Current

Credit: 1 PDH. Course Title: Bearing Fault Detection in Induction Machine Using Squared Envelope Analysis of Stator Current Credit: 1 PDH Course Title: Bearing Fault Detection in Induction Machine Using Squared Envelope Analysis of Stator Current Approved for Credit in All 50 States Visit epdhonline.com for state specific information

More information

Lab VIEW Programming for Vibration Analysis

Lab VIEW Programming for Vibration Analysis IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 01-05 www.iosrjournals.org Lab VIEW Programming for Vibration Analysis A.K.Desai, A.G.Bharate,V.P.Rane,

More information

Fault Diagnosis of an Induction Motor Using Motor Current Signature Analysis

Fault Diagnosis of an Induction Motor Using Motor Current Signature Analysis Fault Diagnosis of an Induction Motor Using Motor Current Signature Analysis Swapnali Janrao and Prof. Mrs. Rupalee Ambekar Department of Electrical Engineering, BVP s College of Engineering (Deemed to

More information