1 USACE / NAVFAC / AFCEC / NASA UFGS (April 2006) Preparing Activity: USACE Superseding UFGS (November 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated April 2018 SECTION TABLE OF CONTENTS DIVISION 27 - COMMUNICATIONS SECTION RADIO AND PUBLIC ADDRESS SYSTEMS 04/06 PART 1 GENERAL 1.1 REFERENCES 1.2 SUBMITTALS 1.3 DELIVERY, STORAGE, AND HANDLING 1.4 EXTRA MATERIALS PART 2 PRODUCTS 2.1 SYSTEM DESCRIPTION Multi-Channel System with Paging Single-Channel System System Performance Detail Drawings 2.2 STANDARD PRODUCTS Identical Items Nameplates 2.3 MIXER-PREAMPLIFIER 2.4 POWER AMPLIFIERS 2.5 MIXER AMPLIFIER 2.6 MICROPHONE INPUT MODULES 2.7 MICROPHONES Desk Microphone Gooseneck Microphone Microphone Jack 2.8 LOUDSPEAKERS Cone Speaker Horn Speaker Dual Horn Speaker High Output Speaker Enclosures Wall Baffle Speaker Enclosures Ceiling Speaker Enclosures 2.9 SPEAKER SWITCHING PANEL Selector Switches System Power supply 2.10 AM/FM EQUIPMENT SECTION Page 1

2 AM/FM Tuner AM/FM Antenna 2.11 COMPACT DISC PLAYER 2.12 CASSETTE TAPE EQUIPMENT 2.13 PRIORITY RELAYS AND CONTROLS 2.14 SWITCHES AND CONTROLS Radio System Control Switch Remote Loudspeaker ON/OFF Switches Remote Loudspeaker Volume Controls 2.15 EQUIPMENT RACKS 2.16 CABLES Speaker Cable Microphone Cable Antenna Cable 2.17 TERMINALS 2.18 SURGE PROTECTION Power Line Surge Protection SIGNAL SURGE PROTECTION 2.19 TELEPHONE INTERFACE MODULE PART 3 EXECUTION 3.1 EXAMINATION 3.2 INSTALLATION Equipment Racks Wiring 3.3 GROUNDING 3.4 TRAINING 3.5 ACCEPTANCE TESTS -- End of Section Table of Contents -- SECTION Page 2

3 USACE / NAVFAC / AFCEC / NASA UFGS (April 2006) Preparing Activity: USACE Superseding UFGS (November 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated April 2018 SECTION RADIO AND PUBLIC ADDRESS SYSTEMS 04/06 NOTE: This guide specification covers the requirements for radio and public address systems. Adhere to UFC Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). PART 1 GENERAL NOTE: This guide specification is to be used in conjunction with Section INTERIOR DISTRIBUTION SYSTEM. If there is a requirement to integrate a Personnel Alerting System (to alert building occupants of eminent threat) to the PA system, assure that the necessary inputs and interfaces are included in this specification. 1.1 REFERENCES NOTE: This paragraph is used to list the publications cited in the text of the guide SECTION Page 3

4 specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a Reference Identifier (RID) outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ELECTRONIC COMPONENTS INDUSTRY ASSOCIATION (ECIA) ECIA EIA/ECA 310-E (2005) Cabinets, Racks, Panels, and Associated Equipment INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) IEEE C IEEE C (2002; R 2008) Guide on the Surges Environment in Low-Voltage (1000 V and Less) AC Power Circuits (2002) Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and Less) AC Power Circuits NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA 70 (2017; ERTA ; TIA 17-1; TIA 17-2; TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6; TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10; TIA 17-11; TIA 17-12; TIA 17-13; TIA 17-14) National Electrical Code UNDERWRITERS LABORATORIES (UL) UL 1449 (2014; Reprint Jul 2017) UL Standard for Safety Surge Protective Devices 1.2 SUBMITTALS NOTE: Review submittal description (SD) definitions in Section SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. The Guide Specification technical editors have SECTION Page 4

5 designated those items that require Government approval, due to their complexity or criticality, with a "G." Generally, other submittal items can be reviewed by the Contractor's Quality Control System. Only add a G to an item, if the submittal is sufficiently important or complex in context of the project. For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the "G" designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy, Air Force, and NASA projects. Use the "S" classification only in SD-11 Closeout Submittals. The "S" following a submittal item indicates that the submittal is required for the Sustainability enotebook to fulfill federally mandated sustainable requirements in accordance with Section SUSTAINABILITY REPORTING. Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects. Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for [Contractor Quality Control approval.][information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability enotebook, in conformance to Section SUSTAINABILITY REPORTING. Submit the following in accordance with Section SUBMITTAL PROCEDURES: SD-02 Shop Drawings Detail Drawings; G[, [ ]] SD-03 Product Data Spare Parts SD-06 Test Reports Approved Test Procedures; G[, [ ]] Acceptance Tests SD-07 Certificates Components SECTION Page 5

6 SD-10 Operation and Maintenance Data Radio and Public Address System; G[, [ ]] 1.3 DELIVERY, STORAGE, AND HANDLING Equipment placed in storage until installation shall be stored with protection from the weather, humidity and temperature variations, dirt and dust, and other contaminants. 1.4 EXTRA MATERIALS Submit spare parts data for each different item of material and equipment specified, after approval of the detail drawings and not later than [2] [ ] months prior to the date of beneficial occupancy. The data shall include a complete list of parts and supplies, with current unit prices and source of supply. PART 2 PRODUCTS 2.1 SYSTEM DESCRIPTION The radio and public address system shall consist of an audio distribution network to include amplifiers, mixers, microphones, speakers, cabling, and ancillary components required to meet the required system configuration and operation. Submit Data Package 3 in accordance with Section OPERATION AND MAINTENANCE DATA Multi-Channel System with Paging The system shall include microphones, microphone outlet receptacles, microphone inputs with preamplifiers, inputs for [film sound,] [compact disc,] [magnetic tape,] [telephone,] [and] [ ] program sources, [single] [all] channel paging, control for each input, power amplifying equipment, and accessories required to output the public address and paging audio signals through selected portions of the audio distribution network as indicated. The paging signal shall replace by zones [channel [ ]] [all channels] of the radio system output, when the paging function is activated Single-Channel System The system shall control and amplify an audio program for distribution within the areas indicated. Components of the system shall include a [mixer-preamplifier,] [mixer-amplifier,] [mike input expander,] [power amplifier,] [microphone,] [speaker system,] [compact disc,] [cassette player,] [AM-FM tuner,] cabling and other associated hardware System Performance The system shall provide even sound distribution throughout the designated area, plus or minus 3 db for the 1/1 octave band centered at 4000 Hz. The system shall provide uniform frequency response throughout the designated area, plus or minus 3 db as measured with 1/3-octave bands of pink noise at locations across the designated area selected by the Contracting Officer. The system shall be capable of delivering 75 db average program level with additional 10 db peaking margin sound pressure level (SPL) in the area at an acoustic distortion level below 5 percent total harmonic distortion (THD). Unless otherwise specified the sound pressure reference level is 20 SECTION Page 6

7 micro Pascal ( Newtons per square meter) Detail Drawings Submit detail drawings consisting of a complete list of equipment and material, including manufacturer's descriptive and technical literature, performance charts and curves, catalog cuts, and installation instructions. Note that the contract drawings show layouts based on typical speakers. Check the layout based on the actual speakers to be installed and make necessary revisions in the detail drawings. Detail drawings shall also contain complete point to point wiring, schematic diagrams and other details required to demonstrate that the system has been coordinated and will properly function as a unit. Drawings shall show proposed layout of equipment and appurtenances, and equipment relationship to other parts of the work including clearances for maintenance and operation. 2.2 STANDARD PRODUCTS Provide materials and equipment which are the standard products of a manufacturer regularly engaged in the manufacture of such products, and that essentially duplicate material and equipment that have been in satisfactory use at least 2 years. All components used in the system shall be commercial designs that comply with the requirements specified. Submit copies of current approvals or listings issued by UL, or other nationally recognized testing laboratory for all components. Equipment shall be supported by a service organization that is within [ ] miles of the site Identical Items Items of the same classification shall be identical. This requirement includes equipment, modules, assemblies, parts, and components Nameplates Each major component of equipment shall have the manufacturer's name, address, model and catalog number, and serial number on a plate secured to the equipment. 2.3 MIXER-PREAMPLIFIER NOTE: Verify that the designated number of inputs are sufficient to meet the requirements of the design and increase the number of inputs if required. Consideration should be given to the use of a mixer-amplifier instead of a mixer-preamplifier/power-amplifier combination. Mixer-amplifiers may not be available for power outputs of 200 watts or greater. Mixer-preamplifier shall as a minimum conform to the following specifications: SECTION Page 7

8 Rated Output Frequency Response Distortion Signal to noise 18 db Plus or Minus 1 db, 20-20,000 Hz Less than 0.5 percent, 20-20,000 Hz Microphone - 60 db Aux - 70 db Inputs Input Sensitivity 5 independent balanced low-impedance transformer-isolated Microphone volts Aux volts Magnetic Cartridge volts Input Channel Isolation Tone Controls Power Requirement 80 db minimum Plus or Minus 10 db range at 50 and 15,000 Hz Vac 60 Hz 2.4 POWER AMPLIFIERS NOTE: The required wattage rating will be inserted in the blank. For radio system, this wattage may be computed as follows: Allow 1 watt for each loudspeaker. Use 1.4 multiplier for reserve power. Auditorium systems will have an output of not less than 20 watts or not less than 10 watts per 100 seats, whichever is greater. Special consideration will be given to acoustics, speaker placement, and the functions for which the system will be used, particularly for large auditoriums where music will be reproduced or amplified. Power amplifiers as a minimum conform to the following specifications: Rated power output Frequency Response Distortion Input Impedance Output Impedance [60] [125] [250] [ ] watts RMS Plus or Minus 3 db, 20-20,000 Hz Less than 2 percent at RPO, ,000 Hz 50 k ohm unbalanced Balanced 4 and 8 ohms SECTION Page 8

9 Output voltage Power Requirement 25 and 70.7 volts Vac 60 Hz 2.5 MIXER AMPLIFIER NOTE: Verify that the designated number of inputs are sufficient to meet the requirements of the design and increase the number of inputs if required. Consideration should be given to the use of a mixer-amplifier instead of a mixer-preamplifier/power-amplifier combination. Mixer-amplifiers may not be available for power outputs of 200 watts or greater. The required wattage rating will be inserted in the blank. For radio system, this wattage may be computed as follows: Allow 1 watt for each loudspeaker. Use 1.4 multiplier for reserve power. Auditorium systems will have an output of not less than 20 watts or not less than 10 watts per 100 seats, whichever is greater. Special consideration will be given to acoustics, speaker placement, and the functions for which the system will be used, particularly for large auditoriums where music will be reproduced or amplified. Mixer amplifier shall as a minimum conform to the following specifications: Rated Power Output (RPO) Frequency Response Distortion Inputs [35] [60] [125] [ ] watts RMS Plus or Minus 3 db, 20-20,000 Hz Less than 1 percent at RPO, 60-13,000 Hz 2 microphones (high impedance or low-impedance unbalanced 2 Aux. (high-impedance) Output Impedance Output Voltage Power Requirement Balanced 4 and 8 ohms 25 and 70.7 volts Vac 60 Hz 2.6 MICROPHONE INPUT MODULES NOTE: Verify that the designated number of inputs are sufficient to meet the requirements of the design and increase the number of inputs if required. SECTION Page 9

10 Microphone input modules shall as a minimum conform to the following specifications: Rated Outputs 0.25 volts into 10,000 ohms 1.0 volts into 10,000 ohms Frequency Response Distortion Inputs Input Sensitivity Input Channel Isolation Plus or Minus 2 db, 20-20,000 Hz Less than 0.5 percent 20-20,000 Hz 4 transformer - coupled balanced 150 ohm volts 70 db minimum 2.7 MICROPHONES Desk Microphone Microphones shall as a minimum conform to the following specifications: Element Pattern Frequency Response Impedance Front-to-back Ratio Selector switches Dynamic Cardioid 50-12,000 Hz Low impedance mic ( ohms) 20 db Selector switches for zone shall be be [integral microphone] or [Separate console adjacent to microphone] Gooseneck Microphone Gooseneck microphone shall meet the minimum requirements of the desk microphone. Microphone shall have push to talk button. Gooseneck tube length shall be [305] [406] [ ] mm [12] [16] [ ] inch Microphone Jack Each outlet for microphones shall consist of a standard outlet box, flush-mounted, and fitted with a three-pole, polarized, locking-type, female microphone jack and a corrosion resistant-steel device plate. 2.8 LOUDSPEAKERS NOTE: Indicate on drawings type of speaker and location. Horn Speaker shall be specified only in SECTION Page 10

11 areas with high ambient noise or outdoors. High output speaker enclosures shall be restricted to large open spaces i.e. gymnasiums, auditoriums or commons Cone Speaker The cone speaker shall as a minimum conform to the following specifications: Application Frequency range Power Rating [Wall baffle] [Ceiling] 60 to 12,000 Hz Normal - [7] [ ] watts Peak - [10] [ ] watts Voice Coil Impedance Line Matching Transformer Type Capacity Magnet Primary Taps Primary Impedance 8 ohms 25/ 70.7 volt line 4 watts 10 ounces or greater 0.5, 1, 2 and 4 watts 25 volts , 625, and 312 ohms 70.7 volts - 10k, 5k, and 2.5k ohms Frequency Response Insertion Loss 30-20,000 Hz Less than 1 db Horn Speaker The horn speaker shall as a minimum conform to the following specifications: Application Frequency Response Power Taps Impedance [Indoor] [Outdoor] [Weatherproof] ,000 Hz 70 volt line -.9, 1.8, 3.8, 7.5, and 15 watts 5000, 2500, 1300, 670, 330, 90, and 45 ohms Normal - [ 7] [ ] watts Peak - [15] [ ] watts SECTION Page 11

12 Dispersion 110 degrees Dual Horn Speaker The dual horn speaker shall meet the minimum requirements of horn speaker except the dispersion shall be 100 degrees High Output Speaker Enclosures High Output speaker enclosures shall be of the tuned-port design for precise balancing and tuning of the speaker. The enclosures shall be constructed throughout of 19.1 mm 3/4 inch high density board, with screwed and glued joints, durably braced, and padded with fiberglass where acoustically required. Speaker enclosures shall have a [25] [45] degree [ ] vertical dispersion and [90] [120] degrees [ ] horizontal dispersion. The effective length of throw shall be a minimum of [15] [40] [60] [ ]m[50] [130] [200] [ ] feet Wall Baffle Speaker Enclosures The wall baffle speaker shall be of particle board construction covered with [walnut laminate] [ ] and complete with [black] [ ] cloth grille. Baffle shall feature 9.5 degree slope to provide directional sound dispersion offset in the direction of radiation. Wall baffle enclosure shall come equipped with a wall mounting bracket designed to assure a rigid mounting to any flat surfaces Ceiling Speaker Enclosures Ceiling speaker enclosure shall be constructed of heavy gauge cold steel with interior undercoating and 38 mm 1-1/2 inch thick high density fiberglass 24 kg/cu. m 1-1/2 lbs/cu. ft. The unit shall be [round] [square] and designed for [recessed] [surface] installations which will be accomplished via [standard screw] [torsion spring] [flange mount] mounting. Recessed models shall have a rust-preventive, [textured black coating] [ ] and the surface mount unit finished in textured [white] [ ]. Enclosure shall include four triple compound conduit knockouts. 2.9 SPEAKER SWITCHING PANEL NOTE: Delete if paging function is not required. Show zone boundaries on the drawings Selector Switches Zone control shall be provided for the paging function. The speaker switching panel shall contain at least [ ] double-pole, [[4-] [3-] position] [push button] selector switches and shall be [rack-mounted] [desk mounted] [selector switches built in microphone]to activate priority relays. Selector switches labeling shall be provided to identify the zones System Power supply Power supply shall be provided for priority relays and controls, rack-mounted and sized for a capacity equal to 200 percent of the as-built SECTION Page 12

13 control system, and shall operate at 24 Vdc. Input and output shall be protected to permit Class 2 wiring in accordance with NFPA AM/FM EQUIPMENT AM/FM Tuner AM/FM tuner shall be rack-mounted and shall as a minimum conform to the following characteristics: Tuning Range AM to 1605 khz FM - 88 to 108 MHz Selectivity 60 db on FM 40 db on AM Sensitivity FM microvolts AM microvolts Capture Ratio Readout/selection Other features Power Requirement 1.0 db Digital Phased Lock Loop (PLL) Vac, 60Hz AM/FM Antenna NOTE: In remote reception areas, an RF preamplifier may be required to receive sufficient FM radio stations. The AM/FM antenna shall be roof-mounted, either combined and suitable for both AM and FM reception or separate AM and FM antennas and shall cover all frequency bands specified for radio tuners. [The antenna system shall be coordinated with the TV system and other systems with antenna communication.] The system shall be furnished complete with a transformer, insulators, crossover insulator, cable of proper length, lightning arresters, coupling transformer and divider network at the radio tuners COMPACT DISC PLAYER NOTE: Multi-disc players utilize a carousel or magazine which will hold and load 5 inch disc for extended unsupervised play. Player shall have three beam laser pickup, dual Digital-to-Analog converters, random access and random mode programmable playback. [Player SECTION Page 13

14 shall have capability to play a minimum of [5] [6] [ ] discs automatically.] Player shall as a minimum conform to the following: Frequency Signal-to-Noise Dynamic Range Total Harmonic Distortion Channel Separation Quantization Conversion Rate Disc Size Power Requirement 10-20,000 Hz Plus or Minus 1 db Minimum of 100 db Minimum of 96 db Maximum of percent at 1 KHZ Minimum 100 db at 1 KHZ Minimum of 18 Bits Linear per channel Minimum 8 x Oversampling 5 inch Vac, 60Hz 2.12 CASSETTE TAPE EQUIPMENT The [dual] cassette tape play deck shall as a minimum conform to the following specifications: Frequency Response Wow and Flutter Signal-to-Noise Noise Reduction system Play Head Operation Power Requirement Plus or minus 3 db, 20-20,000 Hz Less than 0.09 percent WRMS 74 db Dolby [B] [C] [S] [HX PRO] Hard Parmalloy Automatic Reverse Vac, 60 Hz 2.13 PRIORITY RELAYS AND CONTROLS Provide priority relays and controls required to accomplish operations specified. Relays shall be completely enclosed with a plastic dust cover for maximum protection against foreign matter, and shall be plug-in type. Relays shall be provided with a diode wired across the relay coil for transient suppression and shall be installed utilizing factory-prewired, rack-mounted receptacle strips. Coil shall be maximum 24 volts dc. SECTION Page 14

15 2.14 SWITCHES AND CONTROLS Radio System Control Switch NOTE: The multi-channel radio system described is only applicable for hospital and medical facilities and should be specified only where required. Provide the loudspeaker in each room, or group of speakers in a room, with a flush program channel selector rotating-switch knob. The switch shall be mounted at location and height above the floor [as shown] [ ] and in accordance with Section INTERIOR DISTRIBUTION SYSTEM. Install a volume control with a switch at each station of the auto transformer type and set so that the maximum volume is sufficient for the area while not disturbing adjacent areas. If music is turned down or off, the paging signal shall override controls except speakers designated for music only. [Each device plate shall be satin-finished, corrosion-resisting steel permanently marked to indicate the channel selected.] [In neuropsychiatric nursing units, control switches for individual speakers will not be required, but one switch and volume control shall be installed at the Nurses Control Station.] Remote Loudspeaker ON/OFF Switches NOTE: If more than one switch is required, indicate in a schedule on the drawing. Remote switches shall be [key-operated] [toggle switch] 2-pole, wall-mounted, single gang type with engraved switch plates finished to match the approved finish of electrical wall switches. Low-voltage priority override relays shall be provided as part of the switches with all wiring to the racks to allow override of the ON/OFF switches for priority announcements Remote Loudspeaker Volume Controls NOTE: If more than one control is required, indicate in a schedule on the drawing. Remote volume controls shall be an auto transformer type with detented 3 db steps and an OFF position. The controls shall be wall-mounted in single-gang outlet boxes and furnished with engraved switching plates finished to match approved finish of electrical wall switches. Insertion loss of the controls shall not exceed 0.6 db and the power-handling capacities of the control shall be [10] [35] [75] [ ] watts. Low-voltage priority override relays shall be furnished as part of these controls with all wiring to the racks to allow override of the volume controls for priority announcements EQUIPMENT RACKS NOTE: For low powered systems i.e. only paging SECTION Page 15

16 systems,specify perforations or louvers for cooling through convection currents. Systems that are continiously powered i.e. music or radio broadcast and total amplifier capacity exceeding 400 watts use top rack mounted fan option. Equipment shall be mounted on mm 19 inch racks in accordance with ECIA EIA/ECA 310-E and located as shown on drawings. Ventilated rear panels, solid side panels, and solid top panels shall be provided. Equipment racks shall be provided with lockable front panels that limit access to equipment. The lockable front shall not cover items that require operator access such as am/fm tuner, CD player, or tape player. Rack cooling shall be through [perforations or louvers in front panels to ensure adequate ventilation of equipment] [top rack mounted fan]. The racks and panels shall be factory finished with a uniform baked enamel over rust inhibiting primer CABLES Speaker Cable Cables shall be of the gauge required depending upon the cable run length. In no case shall cable be used which is smaller than 18 AWG. Insulation on the conductors shall be polyvinyl chloride (PVC) or an equivalent synthetic thermoplastic not less than 0.2 mm inch. Cables shall be jacketed with a [PVC] [Fluoropolymer] compound. The jacket thickness shall be 0.5 mm 0.02 inch minimum Microphone Cable Cable conductor shall be stranded copper 20 AWG. Insulation on the conductors shall be polyvinyl chloride (PVC) or an equivalent synthetic thermoplastic not less than 0.2 mm inch. Cable shall be shielded 100 percent of aluminum polyester foil with a bare 22 gauge stranded soft copper drain conductor. Cables shall be jacketed with a [PVC] [Fluoropolymer] compound. The jacket thickness shall be 0.5 mm 0.02 inch minimum Antenna Cable Antenna coaxial cable shall have 75 ohm plus or minus 2 ohm. Attenuation of the coaxial cable span between the antenna and amplifier shall not exceed 2.5 db at 108 MHz TERMINALS Terminals shall be [solderless, tool-crimped pressure] [or] [ ] type SURGE PROTECTION Power Line Surge Protection Major components of the system such as power amplifiers, mixer-preamplifiers, and tuners, shall have a device, whether internal or external, which provides protection against voltage spikes and current surges originating from commercial power sources in accordance with IEEE C /IEEE C B3 combination waveform and NFPA 70. Fuses shall not be used for surge protection. The surge protector shall be rated SECTION Page 16

17 for a maximum let thru voltage of 350 Volts ac (line-to-neutral) and 350 Volt ac (neutral-to-ground). Surge protection device shall be UL listed and labeled as having been tested in accordance with UL SIGNAL SURGE PROTECTION Major components of the system shall have internal protection circuits which protects the component from mismatched loads, direct current, and shorted output lines. Communication cables/conductors shall have surge protection installed at each point where it exits or enters a building TELEPHONE INTERFACE MODULE NOTE: Telephone Interface module may be used to access PA system from telephone in conjuction or lieu of microphone. If there is a requirement to integrate Telephone Interface module to the PA system, assure that the necessary inputs and interfaces are included in this specification. Telephone Interface module shall provide one way all call paging access from telephone to PA system. Paging shall be accomplished by the building telephone system instruments interconnected to the PA system via an interface module to allow telephone dial up access to the paging amplifier. Interface module shall produce an alert tone in the associated speakers on activation. Telephone interface module shall as a minimum conform to the following specifications: Impedance Frequency response 70V Input Impedance Output level Input Power Requirement Access requirement 600 ohms 100Hz to 10Khz 200K ohms 400mV rms 12-24Vdc (from power supply) Electronic (analog) or IA2 line key (line card required) PABX loop or ground-start trunk port, or dedicated single-line phone PART 3 EXECUTION 3.1 EXAMINATION After becoming familiar with the details of the work and working conditions, verify dimensions in the field, and advise the Contracting Officer of any discrepancies before performing the work. 3.2 INSTALLATION Install equipment as indicated and specified, and in accordance with the manufacturer's recommendations except where otherwise indicated. Equipment mounted out-of-doors or subject to inclement conditions shall be SECTION Page 17

18 weatherproofed. The antenna shall be supported at least 1.5 m 60 inch clear above the roof by means of self-supported or guyed mast Equipment Racks NOTE: Racks be located adjacent to walls. If a mechanical rack/floor attachment is required, controls shall not be lower than 760 mm 30 inches nor higher than 1.7 m 66 inches above floor; CD, Cassette player and Tuner shall not be lower than 1220 mm 48 inches nor higher than 1525 mm 60 inches above floor. Mount racks side-by-side and bolt together. Group items of the same function together, either vertically or side-by-side. Arrange controls symmetrically at a height as indicated. [CD, Cassette & Tuner shall be at a height above the floor as indicated.] Make audio input and interconnections with approved shielded cable and plug connectors; output connections may be screw terminal type. All connections to power supplies shall utilize standard male plug and female receptacle connectors with the female receptacle being the source side of the connection. Inputs, outputs, interconnections, test points, and relays shall be accessible at the rear of the equipment rack for maintenance and testing. Each item shall be removable from the rack without disturbing other items or connections. Empty space in equipment racks shall be covered by blank panels so that the entire front of the rack is occupied by panels Wiring Install wiring in rigid steel conduit, intermediate metal conduit, cable trays, or electric metallic tubing as specified in Section INTERIOR DISTRIBUTION SYSTEM. Wiring for microphone, grounding, line level, speaker and power cables shall be isolated from each other by physical isolation and metallic shielding. Shielding shall be terminated at only one end. 3.3 GROUNDING All grounding practices shall comply with NFPA 70. The antenna mast shall be separately grounded. Equipment shall be grounded to the serving panelboard ground bus through a green grounding conductor. Metallic conduits serving the equipment shall be isolated on the equipment end with an insulating bushing to prevent noise from being transferred to the circuit. Equipment racks shall be grounded to the panelboard ground bus utilizing a #8 conductor. Grounding conductor shall be terminated to the rack using connector suitable for that purpose. 3.4 TRAINING Conduct a training course for [ ] members of the operating and maintenance staff as designated by the Contracting Officer. The training course will be given at the installation during normal working hours for a total of [ ] hours and shall start after the system is functionally complete but prior to final acceptance tests. The field instructions shall cover all of the items contained in the approved operating and maintenance manuals, as well as demonstrations of routine maintenance operations. Notify the Contracting Officer at least 14 days prior to the start of the SECTION Page 18

19 training course. 3.5 ACCEPTANCE TESTS Submit test reports in booklet form showing all field tests performed to adjust each component and to prove compliance with the specified performance criteria, upon completion and testing of the installed system. The reports shall include the manufacturer, model number, and serial number of test equipment used in each test. Each report shall indicate the final position of controls and operating mode of the system. After installation has been completed, conduct acceptance tests, utilizing the approved test procedures, to demonstrate that equipment operates in accordance with specification requirements. Submit test plan and test procedures for the acceptance tests. The test plan and test procedures shall explain in detail, step-by-step actions and expected results to demonstrate compliance with the requirements specified. The procedure shall also explain methods for simulating the necessary conditions of operation to demonstrate system performance. Notify the Contracting Officer [14] [ ] days prior to the performance of tests. In no case shall notice be given until after the Contractor has received written Contracting Officer approval of the test plans as specified. The acceptance tests shall include originating and receiving messages at specified stations, at proper volume levels, without cross talk or noise from other links or nondesignated units. -- End of Section -- SECTION Page 19

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 51 23.10 (May 2011) ------------------------------ Preparing Activity: USACE Superseding Without Revision UFGS-33 82 01 (August 2009) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 55 80.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 28.36 40 (May 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 53 00.00 40 (November 2015) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 53 00.00 40 (November 2008) UFGS-26 53 00 (August 2008)

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 47 00 (August 2017) ----------------------------- Preparing Activity: USACE Superseding UFGS-11 47 00 (February 2009) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements. Issued 2006/08/01 Section 16724 Public Address System Page 1 of 8 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 33 13 (May 2009) Change 2-11/12 --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 47 00 (February 2009) ----------------------------- Preparing Activity: USACE Superseding UFGS-11 47 00 (January 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 34 59 (August 2008) Change 1-11/12 --------------------------- Preparing Activity: USACE Superseding UFGS-08 34 59 (April 2006) UFGS-08 34 53.00 40 (June 2006) UNIFIED

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 21 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-16822N (August 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-27 05 28.36 40 (August 2011) ----------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-12 36 00.00 20 (August 2011) --------------------------------- Preparing Activity: NAVFAC Superseding UFGS-12 36 00.00 20 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 00 00.00 20 (July 2006) ------------------------------- Preparing Activity: NAVFAC Superseding UFGS-26 00 00.00 20 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 51 13.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 51 13.00 10 (December 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 51 13 (May 2011) ------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 51 13 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-27 51 13.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 51 13.00 10 (December 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-33 34 13 (April 2008) -------------------------- Preparing Activity: USACE Superseding UFGS-33 34 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-27 21 00.00 40 (February 2011) Change 1-11/12 ----------------------------------- Preparing Activity: NASA Superseding UFGS-27 21 00.00 40 (November 2008) UNIFIED FACILITIES

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 51 69.10 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-08582 (August 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-11 42 00 (January 2008) -------------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 40 00.00 20 (April 2006) UFGS 11 46 01.00 10 (April 2006) UNIFIED

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-35 59 13.19 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-02397 (May 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 46 00 (January 2008) ---------------------------- Preparing Activity: USACE Superseding UFGS-11 40 00.00 20 (April 2006) UFGS 11 46 01.00 10 (April 2006) UNIFIED FACILITIES

More information

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components:

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components: SECTION 275123 INTERCOMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Manually switched intercommunications systems with the following components: 1. Master stations (EXISTING).

More information

TOA 500 SERIES MIXER POWER AMPLIFIER

TOA 500 SERIES MIXER POWER AMPLIFIER TOA 500 SERIES MIXER POWER AMPLIFIER Operation Instruction Manual A-503A A-506A A-512A Features General Description 1. High quality design and construction. 2. Full frequency response: 50-15,000Hz, ±3dB.

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-01 58 00 (August 2009) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-01 58 00 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Quadra 10 Available in Black and White

Quadra 10 Available in Black and White S P E C I F I C A T I O N S Quadra 10 Available in Black and White Frequency response, 1 meter on-axis, swept-sine in anechoic environment: 74 Hz 18 khz (±3 db) Usable low frequency limit (-10 db point):

More information

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 74 00 (April 2006) Change 1-08/15 -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-11744 (August 2004) UNIFIED FACILITIES GUIDE

More information

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual Q-Tech Power Amplifiers WARNING THIS APPLIANCE MUST BE EARTHED General Installation DO NOT run unbalanced high impedance microphone cables near mains, data, telephone or 70/100V line cables. DO NOT run

More information

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A Operation Instruction Manual TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A Features General Description 1 6-channel mixer preamplifier 2 Wide frequency response; 20 20,000Hz, ±1dB 3 Low distortion and noise

More information

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46 Instruction Kit GT 60C GT 125C MIXER AMPLIFIER GROMMES-PRECISION 1-800-SINCE-46 www.grommesprecision.com Thank you for purchasing from Grommes~Precision! Grommes~Precision and its commercial audio division,

More information

not overpower the audience just below and in front of the array.

not overpower the audience just below and in front of the array. SPECIFICATIONS SSE LA Description Designed for use in permanent professional installations in churches, theaters, auditoriums, gyms and theme parks, the SSE LA is a dual-radius dius curved line array that

More information

Features: Description

Features: Description Features: Peavey Exclusive Lo Max 18" Subwoofer Extended frequency response down to 33 Hz (half-space) 2400 watts of program power rating Full power low frequency response down to 38 Hz! Neutrik Speakon

More information

Quadra 15 Available in Black and White

Quadra 15 Available in Black and White S P E C I F I C A T I O N S Quadra 15 Available in Black and White Frequency response, 1 meter onaxis, swept-sine in anechoic environment: 64 Hz to 18 khz (±3 db) Usable low frequency limit (-10 db point):

More information

Ambient Level Controller

Ambient Level Controller Ambient Level Controller Installation and Use Manual Issue 1, October 1999 1999 Bogen Communications, Inc. All rights reserved. 54-2028-01 9910 Model: LUALC PEC Code: 5335-621 COM Code: 408184273 Select

More information

SECTION TRANSFORMERS

SECTION TRANSFORMERS SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section

More information

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL 19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL Your new PYRAMID PA305 300 Watt P.A. Amplifier gives you the power and versatility you need in a professional sound

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 35 43 (May 2011) Change 1-05/13 --------------------------- Preparing Activity: NAVFAC Superseding UFGS-26 35 43 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-33 73 00.00 40 (November 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-33 73 00.00 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM.

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM. i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM. Radio Transmitter Contents Quick Start...3 Front and Rear Panel Controls...5

More information

Studio. PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER

Studio. PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER Studio PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER INTRODUCTION Your New PYRAMID PA105/PA205 PA AMPLIFIER gives you the power and versatility you need in a professional sound

More information

TOA PROFESSIONAL POWER AMP

TOA PROFESSIONAL POWER AMP Operating Instruction Manual TOA PROFESSIONAL POWER AMP Model P-150M, P-300M TOA ELECTRIC CO, LTD. KOBE, JAPAN Contents Precautions... 2 General Description... 2 Features... 3 Specifications... 4~5 Performance

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

Distributed Design Series

Distributed Design Series APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-12 24 13 (August 2017) --------------------------- Preparing Activity: USACE Superseding UFGS-12 24 13 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports Nightclubs, bars, restaurants The is

More information

ART300A SPEAKER ART300A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

ART300A SPEAKER ART300A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series ART Series Two-Way Active Speaker System SPEAKER Careful acoustic design and advanced materials have resulted in an exceptional full range, full fidelity, self-contained sound system. The provides an ideal

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-12 35 39 (August 2017) Change 1-08/18 --------------------------- Preparing Activity: USACE Superseding UFGS-12 35 39 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure TCS SERIES ENGINEERING INFORMATION TCS- The TCS- is a passive full range two-way loudspeaker enclosure designed for use as an under balcony theatre speaker or as a downfill enclosure when used with flown

More information

Studio MODEL:PA600X/PA800X/PA1000X/ PA1800X PA AMPLIFIER PRO. High Performance Professional Audio.

Studio MODEL:PA600X/PA800X/PA1000X/ PA1800X PA AMPLIFIER PRO. High Performance Professional Audio. Studio PRO High Performance Professional Audio MODEL:PA600X/PA800X/PA1000X/ PA1800X PA AMPLIFIER www.pyramidcaraudio.com INTRODUCTION Your New PYRAMID PA SERIES AMPLIFIER gives you the power and versatility

More information

TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A. General Description. TOA Corporation. Operation Instruction Manual

TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A. General Description. TOA Corporation. Operation Instruction Manual Operation Instruction Manual TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A Features 1 3-channel mixer power amplifier 2 Wide frequency response; 20 20,000 Hz, ±1dB 3 Low distortion and noise level 4

More information

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in the mains lead are coloured In accordance with the following code: Green and Yellow:

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series ART Series Two-Way Active Speaker System SPEAKER Careful acoustic design and advanced materials have resulted in an exceptional full range, full fidelity, self-contained sound system. The provides an ideal

More information

FreeSpace DS 40SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

FreeSpace DS 40SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications FreeSpace DS 4SE Key Features Full-range with a single 4.5" (114 mm) full-range driver in a ported enclosure designed for surface mounting in foreground and background music and paging applications Simple

More information

datasheet IMPACT 50 IMPACT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Attractive injection moulded enclosure 100 watt power rating

datasheet IMPACT 50 IMPACT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Attractive injection moulded enclosure 100 watt power rating IMPACT SERIES ENGINEERING INFORMATION The Impact series of full range, passive loudspeakers has been designed to be used in a variety of installed sound system applications ranging from discotheques, clubs

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 13 DISTRIBUTION SWITCHBOARDS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Quadra 12 Available in Black and White

Quadra 12 Available in Black and White S P E C I F I C A T I O N S Quadra 12 Available in Black and White Frequency response, 1 meter onaxis, swept-sine in anechoic environment: 76 Hz to 18 khz (±3 db) Usable low frequency limit (-10 db point):

More information

Self-Amplified Horn Speakers

Self-Amplified Horn Speakers Self-Amplified Horn Speakers Self-Amplified Horn Speakers High-Efficiency, Digital Switching, Self-Amplified Horn Loudspeakers SAH SAH (W) (W) Using digital switching amplifier technology, the SAH and

More information

DVS 4 / DVS 4t. Features. Product Description. Applications

DVS 4 / DVS 4t. Features. Product Description. Applications UL-148, UL3 Product Description Designed for a wide variety of discrete small scale sound reinforcement applications, the Tannoy DVS 4 is an ultra compact surface mount loudspeaker of exceptional value

More information

411LA Broadband Power Amplifier

411LA Broadband Power Amplifier 411LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with

More information

SPECIFICATIONS QW -215

SPECIFICATIONS QW -215 Box tuning frequency: 40 Hz Harmonic distortion: 1% rated power Second Harmonic: Hz:.58% 500 Hz:.33% Third Harmonic: Hz:.19% 500 Hz:.33% 10% rated power Second Harmonic: Hz: 1.90% 500 Hz: 1.30% Third Harmonic:

More information

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System 2004 Specifications CSJ 0002-01-074, etc. SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System 1. Description. This Item governs the furnishing and installation of emergency

More information

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions MIXING CONSOLE Operating Instructions CX-124 CX-164 Please follow the instructions in this manual to obtain the optimum results from these units. We also recommend you to keep this manual handy for future

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 35 44.00 20 (February 2018) ----------------------------------- Preparing Activity: NAVFAC UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with

More information

Di5DC. Product Description. Features. Applications

Di5DC. Product Description. Features. Applications Product Description Designed for a wide variety of sound reinforcement applications, the Tannoy Di5 DCt is a high performance, ultra compact surface mount weather resistant loudspeaker. A full bandwidth

More information

FreeSpace DS 16SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

FreeSpace DS 16SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications Key Features Full-range with a single 2.25" (57 mm) full-range driver in a ported enclosure designed for surface mounting in background music and paging applications Simple 1->2->3 installation system.

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

Owner s Manual.

Owner s Manual. P Z R 6 0 0 A m p l i f i e r P Z R 1 0 0 0 A m p l i f i e r Owner s Manual www.pyleaudio.com Your New Pyle Pro PZR series P.A. Amplifier gives you the power and versatility you need in a professional

More information

Di6DC. Product Description. Features. Applications

Di6DC. Product Description. Features. Applications Product Description Designed for a wide variety of sound reinforcement applications, the Tannoy Di6 DC is a high performance, ultra compact surface mount weather resistant loudspeaker. A full bandwidth

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 11 SPEC WRITER NOTES: Use this section only for NCA projects. Delete between // -- // if not applicable to project. Also delete any other item or paragraph

More information

datasheet TQ-315 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide

datasheet TQ-315 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide The is a trapezoidal, switchable active/passive, full range two-way loudspeaker enclosure designed for use in mobile speech and music sound reinforcement applications as well as in a wide range of fixed

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

TOA 900 SERIES POWER AMPLIFIER P-924A

TOA 900 SERIES POWER AMPLIFIER P-924A Operation Instruction Manual TOA 900 SERIES POWER AMPLIFIER P-924A Features General Descriptions 1 Wide frequency response; 20 20,000 Hz, ±1dB 2 Low distortion and noise level 3 Excellent output regulation

More information

FreeSpace DS 40F flush-mount loudspeaker

FreeSpace DS 40F flush-mount loudspeaker TECHNICAL DATA PROFESSIONAL Product Overview The Bose is the most versatile member of the DS loudspeaker family. It is a highperformance, full-range, flushmount loudspeaker designed for foreground and

More information

SPECS. Impulse (4 and 8 ohm) Two-Way Weather-Resistant Injection-Molded Speaker System SPECIFICATIONS. Built under U.S.

SPECS. Impulse (4 and 8 ohm) Two-Way Weather-Resistant Injection-Molded Speaker System SPECIFICATIONS. Built under U.S. SPECS P E A V E Y E L E C T R O N I C S Impulse 1012 (4 and 8 ohm) Two-Way Weather-Resistant Injection-Molded Speaker System Built under U.S. Patent 6,064,745 SPECIFICATIONS Enclosure: Peavey Impulse 1012

More information

3.Avoid spilling liquids or allowing materials to enter the cabinet

3.Avoid spilling liquids or allowing materials to enter the cabinet PUBLIC ADDRESS MIXER POWER AMPLIFIER INSTRUCTION MANUAL PL-260A 260 WATT RMS RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN COVER. NO USER SERVICEABLE PARTS

More information

Di6 / Di6t. Product Description

Di6 / Di6t. Product Description Product Description Designed for a wide variety of sound reinforcement applications, the Tannoy Di6t is a high performance, ultra compact surface mount weather resistant loudspeaker. A full bandwidth loudspeaker

More information

PagePac Plus AmpliCenter V A - (D300A) V A - (D100A) V (D40) Installation and Use

PagePac Plus AmpliCenter V A - (D300A) V A - (D100A) V (D40) Installation and Use Issue 3 IMPORTANT SAFETY INFORMATION: PagePac Plus AmpliCenter V-5328300A - (D300A) V-5328100A - (D100A) V-5328040 - (D40) Installation and Use 1. Read these instructions. 2. Keep these instructions. 3.

More information

***************************************************************************** DRAFT UFGS- 01 XX XX (FEB 2014)

***************************************************************************** DRAFT UFGS- 01 XX XX (FEB 2014) DRAFT UFGS- 01 XX XX (FEB 2014) ------------------------ Drafting Activity: USACE UNIFIED FACILITIES GUIDE SPECIFICATION SECTION TABLE OF CONTENTS DIVISION 01 GENERAL REQUIREMENTS SECTION 01 XX XX (FEB

More information

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1995 Metric CSJ's 1047-03-056 & 0008-08-066 SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation

More information

PROFESSIONAL POWER AMP

PROFESSIONAL POWER AMP Operating Instruction Manual PROFESSIONAL POWER AMP Model P-75D, P-150D, P-300D P-75D P-150D P-300D TOA Corporation KOBE, JAPAN Contents Precautions... 1 General Description... 2 Features... 2~ 3 Specifications...

More information

SA1521 SPEAKER SA1521 SA1521. Features. Applications Live Applications Playback Applications Portable PA Systems Corporate Events

SA1521 SPEAKER SA1521 SA1521. Features. Applications Live Applications Playback Applications Portable PA Systems Corporate Events The is an active 2-way sound reinforcement speaker system designed for extreme accuracy, high output, and smooth dispersion across the entire audio frequency range. It integrates 5 watts of amplifier power,

More information

FAP63T-W 1/7. FAP Strategy III Series Ceiling Loudspeaker. Features. General Description. Applications. AtlasIED.com FAP63T-W

FAP63T-W 1/7. FAP Strategy III Series Ceiling Loudspeaker. Features. General Description. Applications. AtlasIED.com FAP63T-W 1/7 FAP63T-W FAP Strategy III Series Ceiling Loudspeaker 216 Atlas Sound L.P. and Innovative Electronic Designs, LLC. All Rights Reserved. Atlas Sound is a trademark of Atlas Sound L.P. IED is a registered

More information

AM10. architectual. Full-range weatherised enclosure. features. applications

AM10. architectual.   Full-range weatherised enclosure. features. applications features! Compact two-way passive system! Textured high-density polyurethane coating both internal and external! User rotatable 90º x 50º horn! High power output! Five year limited warranty applications!

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY Section 16195 A. This Section includes electrical identification for the following: 1. Nameplates and labels 2. Wire and cable markers 3. Conduit markers 4. Cable tray markers

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-33 73 00.00 40 (November 2008) ----------------------------------- Preparing Activity: NASA Superseding UFGS-33 73 00.00 40 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

datasheet TQ-445 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Three-way, bi-amp design Exceptional audio clarity 60 x 40 dispersion

datasheet TQ-445 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Three-way, bi-amp design Exceptional audio clarity 60 x 40 dispersion The is a three-way bi-amped full range enclosure that offers unprecedented levels of audio clarity and definition. It incorporates a custom-designed co-axial 12 /1 driver in an optimally tuned vented trapezoidal

More information

WALTx-2 Instruction Manual Weatherproof Volume Control

WALTx-2 Instruction Manual Weatherproof Volume Control waltx-2 Manual 5/16/07 12:32 PM Page 1 WALTx-2 Instruction Manual Weatherproof Volume Control WEATHERPROOF VOLUME CONTROL waltx-2 Manual 5/16/07 12:32 PM Page 2 Product Overview The WALTx-2 Weatherproof

More information

MIXER POWER AMPLIFIER BG-130

MIXER POWER AMPLIFIER BG-130 OPERATING INSTRUCTIONS MIXER POWER AMPLIFIER BG-115 BG-130 TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

More information