SD Series. AC Spindle Motor Drives with Power Regeneration, AC Servo Drives. Speed Reference with Analog Voltage Expanded Functions

Size: px
Start display at page:

Download "SD Series. AC Spindle Motor Drives with Power Regeneration, AC Servo Drives. Speed Reference with Analog Voltage Expanded Functions"

Transcription

1 AC Spindle Motor Drives with Power Regeneration, AC Servo Drives SD Series Speed Reference with Analog Voltage Expanded Functions Power Regeneration Converter Model CACP-JU SERVOPACK Model CACR-JU Spindle Motor Model UAK J Single-winding Motors 2 V 3.7/2.2 kw to 45/37 kw 4 V 3.7/2.2 kw to 22/18.5 kw Winding Selection Motors 2 V 5.5/3.7 kw to 3/2 kw 4 V 5.5/3.7 kw to 22/18.5 kw Certified for ISO91 and ISO141 JQA-422 JQA-EM22 JQA-EM924

2 AC Spindle Motor Drives with Power Regeneration AC Servo Drives Power Regeneration n Converter and SERVOPACK Block configuration with unified heights and depths to help optimize control panel designs. Two mounting methods: Duct ventilated (external heat sink cooling) and base mounting (in-panel mounting). SERVOPACKs are available with three orientation methods: Motor encoder, external encoder, or magnetic sensor. Digital speed references with contact inputs (12 bits). Front covers make cables easy to organize. Power Regeneration Converter Power supply regeneration helps save energy. SERVOPACK for AC Spindle Motor Drive Servo drive control technology has been applied to spindle drives to increase amplifier response characteristics. High-precision speed control is achieved. * : Ask your Yaskawa representative for information on the KC Mark. * You can use Yaskawa s SigmaWin+ Engineering Tool* 1 to easily motor constant settings* 2, trace data, check I/O signals, and edit parameters. 2 * * 1 : SigmaWin+ Ver.5.7 or later (Please be used with -SD component Ver.1. or later) 2 : Be sure to set the Motor constant settings by using SigmaWin+. (Visit the desingnated Yaskawa Electric website for your area. Use the inquiry form to request the SigmaWin+, -SD component, motor constant files.)

3 Spindle Motor Optimum electromagnetic design and improved cooling structure for high efficiency, downsizing, and reduced weight. High acceleration/deceleration rates with maximum output power of 2% to help improve productivity when used as high-speed, high-power output spindle motors. Downsizing for low moment of inertia and instantaneous power that approach servo performance. Minimal loss of cooling capacity in adverse environments for high reliability. Maximum Output Power: 2% Winding selection for wide-range constant output power of 1:12. This increases processing capacity, simplifies gear structure, and reduces the capacity of the applicable drives. Wide-range Constant Output Power: 1:12 3

4 Model Designation Spindle Motor UAKAJ- 22CZ1 OOE AC Spindle Motor Cooling Method K : External fan cooled Winding System A : Single winding B : Winding selection Series J : SD Series 5% ED Rating (S3) * Code 4* * 2 37* 1 * 2 45* 1 * 2 Specifications (kw) Design Revision Order C : Standard 1 : Available only for single winding models. 2 : Available only for three-phase 2 VAC models. Input Voltage Blank : Three-phase 2 VAC E : Three-phase 4 VAC Lead Wire Orientation Blank : Left when viewed from the load side (for 2-VAC input spindle motor) O : Left when viewed from the load side (for 4-VAC input spindle motor) Shaft End Blank : Straight with key and tap (for 2-VAC input spindle motor) O : Straight with key and tap (for 4-VAC input spindle motor) N : Straight without key and tap Mounting 1 : Flange type 3 : Foot-mounted type Encoder Specifications Z : Pulse encoder SD Driver Power Regeneration Converter * CACP- JU22A 3 SD Series Power Regeneration Converter 5% ED Rating Code Specifications (kw) * * 1 45 Input Voltage A : Three-phase 2 VAC D : Three-phase 4 VAC 1 : Available only for three-phase 2 VAC models. 2 : Available only for CACP-JU A3BB model. Custom-made Blank : Standard Mounting Blank : Duct-ventilated B* 2 : Base-mounted Design Revision Order A : Corresponds to the UL standard B : Not correspond to the UL standard Regeneration Method 3 : 12-degree conduction SERVOPACK CACR- JU12AEA SD Series SERVOPACK Rated Output Current Code Specifications (Arms) Input Voltage VDC 54 VDC : Available only for CACR-JU AEAB model. * Custom-made Blank : Standard 1 : Orientation control with an external encoder 2 : Orientation control with a magnetic sensor Mounting Blank : Duct-ventilated B* : Base-mounted Design Revision Order A B C Interface Specifications E : Analog speed reference expanded functions Input Voltage A : 27 VDC D : 54 VDC 4 For details about custom-made spindle motors, converters, or SERVOPACKs, contact your Yaskawa representative.

5 Combinations Single Winding Single Winding Winding Selection Winding Selection 2 VAC-input Spindle Motor UAKAJ-4C UAKAJ-6C UAKAJ-8C UAKAJ-11C UAKAJ-15C UAKAJ-19C UAKAJ-22C UAKAJ-3C UAKAJ-37C UAKAJ-45C UAKBJ-6C UAKBJ-8C UAKBJ-11C UAKBJ-15C UAKBJ-19C UAKBJ-22C UAKBJ-3C 4 VAC-input Spindle Motor UAKAJ-4C UAKAJ-6C UAKAJ-8C UAKAJ-11C UAKAJ-15C UAKAJ-19C UAKAJ-22C UAKBJ-6C UAKBJ-8C UAKBJ-11C UAKBJ-15C UAKBJ-19C UAKBJ-22C E E E E E E E E E E E E E Power Regeneration Converter Model CACP- JU15A3 JU19A3 JU22A3 JU3A3 JU45A3B JU15A3 JU19A3 JU22A3 JU3A3 Power Regeneration Converter Model CACP- JU15D3 JU19D3 JU22D3 JU15D3 JU19D3 JU22D3 SERVOPACK Model CACR- JU28AEA JU36AEA JU65AEA JU84AEA JU12AEA JU125AEA JU196AEA JU28AEA JU36AEA JU65AEA JU84AEA JU12AEA JU125AEA SERVOPACK Model CACR- JU14DEA JU18DEA JU33DEA JU42DEA JU51DEA JU14DEA JU18DEA JU33DEA JU42DEA JU51DEA : For the Magnetic Contactor of UL-compliant type or with safety cover, refer to page 6. * AC Reactor X817 X818 X819 X82 X822 X817 X818 X819 X82 AC Reactor X81 X811 X812 X81 X811 X812 Magnetic Contactor for Winding Selection* HV-75AP4 HV-15AP4 Magnetic Contactor for Winding Selection* HV-75AP4 HV-15AP4 C O N T E N T S Spindle Motor 6 Ratings and Specifications Output and Torque Characteristics Tolerance Radial Loads Motor Total Indicator Readings Vibration Resistance External Dimensions Power Regeneration Converter 2 Basic Specifications External Dimensions Installation 36 Spindle Motor 36 -SD Driver 4 (Power Regeneration Converter and SERVOPACK Selecting Cables 44 System Configurations I/O Signal Spindle Motor -SD Driver Peripheral Devices 58 AC Reactor Magnetic Contactor for Winding Selection 2 21 SERVOPACK 26 Basic Specifications External Dimensions MCCB, Ground Fault Detector, and Magnetic Contactor 62 Noise Filter 63 Base Mounting Unit 67 External Encoder 71 Magnet and Magnetic Sensor 72 Warranty 74 5

6 Spindle Motor Ratings and Specifications Single-winding Motor Items *1. The 5% ED rating (S3) is for a 1 minute cycle consisting of 5 minutes of operation and 5 minutes stopped. *2. Available only for three-phase, 2 VAC models. Model: UAKAJ- C (2 V), - C E (4 V) *2 37 *2 45 *2 5% ED Rating (S3) *1 kw Continuous Rating (S1) kw Continuous Rated Torque N m Base Speed min Maximum Speed min Moment of Inertia 1-3 kg m Vibration V5 V1 Noise db (A) 75 or less 8 or less Cooling Method Totally enclosed, external fan cooled Protection Class IP44 (IEC34-5) Equipped with thermostat (automatic reset) 2 V class: Cooling Fan Motor Three-phase 2 V 5/6 Hz, 22 V 5/6 Hz, 23 V 6 Hz 4 V class: Three-phase 4 V 5/6 Hz, 44 V 5/6 Hz, 46 V 6 Hz Encoder (Magnetic) Pulse encoder (124 p/r) Overheating Protection NTC thermistor Flange type: Installation IM B5, IM V1 (motor shaft from horizontal to vertically down) Foot-mounted type: IM B3 (installed on floor) Overload Capacity 2% of continuous rated (S1) output for 1 s (UAKAJ-8, -37: 18% of continuous rated (S1) output for 1 s) Thermal Class F Withstand Voltage 2 V class: 15 VAC for one minute 4 V class: 18 VAC for one minute Insulation Resistance 5 VDC 1 MΩ minimum Surrounding Air Temperature and Surrounding Air Humidity C to 4 C, 2% to 8% RH (no condensation) Altitude 1 m or less Bearing Lubrication Grease Paint Color Munsell N1.5 Compliant Standards JIS, JEC Applicable SERVOPACK CACR- JU Three-phase 2 VAC Three-phase 4 VAC 28A 28A 36A 65A 65A 84A 12A 125A 196A 196A 14D 14D 18D 33D 33D 42D 51D 6

7 Spindle Motor Ratings and Specifications Winding Selection Motor Items Model: UAKBJ- C (2 V), - C E (4 V) *2 5% ED Rating (S3) *1 kw Continuous Rating (S1) kw Continuous Rated Torque N m Base Speed min Maximum Speed min Moment of Inertia 1-3 kg m Vibration V5 V1 Noise db (A) 75 or less 8 or less Cooling Method Totally enclosed, external fan cooled Protection Class IP44 (IEC34-5) Equipped with thermostat (automatic reset) 2 V class: Cooling Fan Motor Three-phase 2 V 5/6 Hz, 22 V 5/6 Hz, 23 V 6 Hz 4 V class: Three-phase 4 V 5/6 Hz, 44 V 5/6 Hz, 46 V 6 Hz Encoder (Magnetic) Pulse encoder (124 p/r) Overheating Protection NTC thermistor Flange type: Installation IM B5, IM V1 (motor shaft from horizontal to vertically down) Foot-mounted type: IM B3 (installed on floor) Overload Capacity 2% of continuous rated (S1) output for 1 s Thermal Class F Withstand Voltage 2 V class: 15 VAC for one minute 4 V class: 18 VAC for one minute Insulation Resistance 5 VDC 1 MΩ min. Surrounding Air Temperature and Surrounding Air Humidity C to 4 C, 2% to 8% RH (no condensation) Altitude 1 m or less Bearing Lubrication Grease Paint Color Munsell N1.5 Compliant Standards JIS, JEC Applicable Three-phase 2 VAC 28A 36A 65A 65A 84A 12A 125A SERVOPACK CACR-JU Three-phase 4 VAC 14D 18D 33D 33D 42D 51D Spindle Motor *1. The 5% ED rating (S3) is for a 1 minute cycle consisting of 5 minutes of operation and 5 minutes stopped. *2. Available only for three-phase, 2 VAC models. 7

8 Spindle Motor Output and Torque Characteristics Output and Torque Characteristics Single-winding Motors Model UAKAJ- Output Characteristics Torque Characteristics 4C Output (kw) 5 ED rating second rating Continuous rating Torque (N m) second rating ED rating 14. Continuous rating C Output (kw) second rating ED rating 3.7 Continuous rating Torque (N m) second rating 5 ED rating Continuous rating C Output (kw) 1 1 second rating ED rating 5.5 Continuous rating Torque (N m) second rating 5 ED rating Continuous rating C Output (kw) 15 1 second rating 5 ED rating Continuous rating Torque (N m) second rating 7. 5 ED rating Continuous rating second rating 14 1 second rating 15C Output (kw) 15 5 ED rating 11 Continuous rating Torque (N m) ED rating Continuous rating Continued on next page. 8

9 Spindle Motor Output and Torque Characteristics Model UAKAJ- 19C Output (kw) Output Characteristics 5 ED rating 3 1 second rating Continuous rating 12.8 Torque (N m) Continued from previous page. Torque Characteristics second rating ED rating Continuous rating 95.5 Spindle Motor ED rating 37 1 second rating second rating 22C Output (kw) Continuous rating Torque (N m) ED rating Continuous rating C Output (kw) 5 ED rating 44 1 second rating 3 22 Continuous rating Torque (N m) second rating 5 ED rating Continuous rating C Output (kw) 5 ED rating 54 1 second rating 37 3 Continuous rating second rating 5 ED rating 37 Torque (N m) 249 Continuous rating ED rating 74 1 second rating second rating 45C Output (kw) Continuous rating Torque (N m) ED rating Continuous rating

10 Spindle Motor Output and Torque Characteristics Winding Selection Motors Model UAKBJ- Output Characteristics Torque Characteristics High-speed winding Output (kw) second rating ED rating 3.7 Continuous rating High-speed winding second rating 5 ED rating 35. Torque Continuous rating (N m) C Low-speed winding Low-speed winding Output (kw) second rating ED rating 3.7 Continuous rating Torque (N m) second rating 15 Continuous rating 5 ED rating High-speed winding High-speed winding 7. 1 second rating Output (kw) 11 1 second rating ED rating 5.5 Continuous rating Torque (N m) ED rating Continuous rating 8C Low-speed winding Output (kw) second rating ED rating 5.5 Continuous rating Low-speed winding second rating 143 Continuous rating 5 ED rating Torque 15 (N m) Continued on next page. 1

11 Spindle Motor Output and Torque Characteristics Continued from previous page. Model UAKBJ- High-speed winding Output (kw) Output Characteristics 15 1 second rating 11 5 ED rating 7.5 Continuous rating High-speed winding Torque (N m) Torque Characteristics second rating 7. 5 ED rating 47.8 Continuous rating Spindle Motor 11C Low-speed winding Output (kw) second rating 11 5 ED rating 7.5 Continuous rating 6 7 Low-speed winding Torque (N m) second rating 21 5 ED rating Continuous rating High-speed winding Output (kw) 22 1 second rating 15 5 ED rating 11 Continuous rating High-speed winding Torque (N m) 21 1 second rating ED rating Continuous rating 15C Low-speed winding Low-speed winding Output (kw) 18 1 second rating 15 5 ED rating 11 Continuous rating Torque (N m) 43 1 second rating ED rating Continuous 263 rating Continued on next page. 11

12 Spindle Motor Output and Torque Characteristics Model UAKBJ- High-speed winding Output Characteristics High-speed winding Continued from previous page. Torque Characteristics Output (kw) 3 1 second rating ED rating 15 Continuous rating Torque (N m) second rating 5 ED rating 118 Continuous rating C Low-speed winding Output (kw) Continuous rating second rating ED rating Low-speed winding Torque (N m) second rating 37 Continuous rating ED rating High-speed winding Output (kw) second rating 22 5 ED rating 18.5 Continuous rating High-speed winding Torque (N m) second rating ED rating Continuous rating 22C Low-speed winding Output (kw) second rating 22 5 ED rating Continuous rating Low-speed winding Torque (N m) second rating Continuous rating 5 ED rating Continued on next page. 12

13 Spindle Motor Output and Torque Characteristics Continued from previous page. Model UAKBJ- High-speed winding Output (kw) Output Characteristics 4 1 second rating 3 5 ED rating 2 Continuous rating High-speed winding Torque (N m) Torque Characteristics second rating Continuous rating ED rating 127 Spindle Motor 3C Low-speed winding Output (kw) second rating 3 5 ED rating 2 Continuous rating Low-speed winding Torque (N m) second rating 498 Continuous rating ED rating

14 Spindle Motor Tolerance Radial Loads Tolerance Radial Loads Model: UAKAJ-, UAKBJ- Rated Output (kw) 5%ED Rating/ Continuous Rating *1. Available only for three-phase, 2 VAC models. *2. The rated output for the winding selection motor is 3/2 kw. Single-winding Motor Model: UAKAJ- C Tolerance Radial Load (N) Winding Selection Motor Model: UAKBJ- C 4 3.7/ / / / / / / *1 3/22 * *1 37/ *1 45/37 52 Motor Total Indicator Readings Flange Type Item Perpendicularity of the flange face to the motor shaft Concentricity of the flange mating part to the motor shaft Axial runout of the motor shaft Single-winding Motor: UAKAJ- Model Winding Selection Motor: UAKBJ- Accuracy 4 to 22 6 to 11.4 mm 3, mm to 3.72 mm 4 to 11.4 mm 15 to 22 6 to mm 3, mm to 3.7 mm 4 to 8.2 mm 11 to 22 6 to mm 3 to to 3.28 mm Foot-mounted Type Item Shaft Parallelism Axial runout of the motor shaft Single-winding Motor: UAKAJ- Model Winding Selection Motor: UAKBJ- Accuracy 4 to 8.3 mm 11 to 22 6 to mm 3 to to 3.42 mm 4 to 8.2 mm 11 to 22 6 to mm 3 to to 3.28 mm 14

15 Spindle Motor Vibration Resistance Vibration Resistance Front to Back Vertical Impact Applied to the Spindle Motor Side to Side The spindle motor will withstand the following vibration acceleration in three directions: Vertical, side to side, and front to back. Winding System Single Winding Winding Selection Spindle Motor Model Vibration Acceleration at Flange UAKAJ-4 to m/s 2 UAKAJ-3, m/s 2 UAKAJ m/s 2 UAKBJ-6, -8, m/s 2 UAKBJ-15 to m/s 2 UAKBJ m/s 2 Vibration Frequency Constant Amplitude 1 Hz to 6 Hz Constant Acceleration 6 Hz to 25 Hz Spindle Motor Important The amount of vibration the spindle motor endures will vary depending on the application. Check the vibration acceleration being applied to your motor for each application. 15

16 Spindle Motor External Dimensions I External Dimensions Single-winding Motors Flange type KD Shaft Extension LC LH LA KI QK W U D Q LB LG 5 LL L LR KL 4-Z dia. mounting holes QR Q T 3-m screw*, depth 1 * For 3.7/2.2 kw motors: 2-m screw S d Model UAKAJ- Unit: mm L LA LB LC LG LH LL LR Z D I KD KL KI Model UAKAJ Shaft End Dimensions Q QK QR S T U W d m Note: 1. The shaft key and the keyway are standard JIS B models. 2. The figures are provided only to explain the dimensions. The actual appearance of the spindle motor may vary. Approx. Mass kg M M M M M M M M M M

17 Spindle Motor External Dimensions Foot-mounted type D KI C H KD A L R B Q Shaft Extension QK T W d U Spindle Motor J E M 4-Z dia. mounting holes J E G F F N XB QR Q S 3-m screw*, depth 1 * For 3.7/2.2 kw motors: 2-m screw Model UAKAJ- Note: 1. The shaft key and the keyway are standard JIS B models. 2. The figures are provided only to explain the dimensions. The actual appearance of the spindle motor may vary. Unit: mm A B C D E F G H J KD L M N R Model UAKAJ- XB Z KI Shaft End Dimensions Q QK QR S T U W d m Approx. Mass kg M M M M M M M M M M

18 Spindle Motor External Dimensions I Winding Selection Motors Flange type KD Shaft Extension D LL L LC LH LA KI QK T W d U Q LG 5 LR KL 4-Z dia. mounting holes QR Q S 3-m screw, depth 1 LB Model UAKBJ- Note: 1. The shaft key and the keyway are standard JIS B models. 2. The figures are provided only to explain the dimensions. The actual appearance of the spindle motor may vary. Unit: mm L LA LB LC LG LH LL LR Z D I KD KL KI Model UAKBJ Shaft End Dimensions Q QK QR S T U W d m Approx. Mass kg M M M M M M M

19 Spindle Motor External Dimensions Foot-mounted type D KI C H KD A L R B Q Shaft Extension QK T W d U Spindle Motor 4-Z dia. mounting holes J E M J E G F F N XB QR Q S 3-m screw, depth 1 Model UAKBJ- Note: 1. The shaft key and the keyway are standard JIS B models. 2. The figures are provided only to explain the dimensions. The actual appearance of the spindle motor may vary. Unit: mm A B C D E F G H J KD L M N R Model UAKBJ- XB Z KI Shaft End Dimensions Q QK QR S T U W d m Approx. Mass kg M M M M M M M

20 Power Regeneration Converter Basic Specifications Item Model: CACP-JU A3, CACP-JU D3 *1. Available only for three-phase 2 VAC models. *2. Needed when using a base mounting unit. For details, refer to page 67. Specifications *1 45 *1 5% ED Rating kw Continuous Rating kw Basic Specifications Functions Input Power Output Power Input Signals Main Circuits L1, L2, and L3 Control Power Power Supply for Fan *2 Main Circuit Power Output +/ Control Power Output Sequence Input Signals Regeneration Control Method Protective Functions Allowable Power Loss Time Connections between SERVOPACKs Indications CACP-JU A3 : Three-phase 2 V to 23 V (5/6 Hz) CACP-JU D3 : Three-phase 38 V to 48 V (5/6 Hz) Allowable voltage fluctuation: +1% to 15% Allowable frequency fluctuation: ±5% Voltage unbalance (between U, V, or W phase): 5% max. 24 VDC Allowable voltage fluctuation: ±15% Output holding time: 1 ms minimum 24 VDC CACP-JU A3 : 27 to 31 VDC CACP-JU D3 : 52 to 65 VDC 24 VDC ±15% (connector pass current: 1 A) Emergency stop input signal Input power voltage: 24 VDC ±5% Required current per channel: 3 ma Power regeneration control (12-degree conduction) Main circuit fuse, overload, overvoltage, insufficient voltage, overcurrent, frequency error, heat sink overheating, etc. 5 ms (at 7% load) Local bus CHARGE (orange), ALARM (red), and READY (green) Panel Display The status of power regeneration converter can be checked on the panel display. Name LED Color Meaning CHARGE Orange Lit when main circuit power is on. Not lit when main circuit power is off. ALARM Red Lit when alarm occurs. Not lit when no alarm occurs. READY Green Lit when CPU of power regeneration converter works normally. Not lit when CPU of power regeneration converter not working. 2

21 Power Regeneration Converter External Dimensions Power Regeneration Converter Panel Display Power Regeneration Converter External Dimensions Duct-ventilated Type Model: CACP-JU15 3, -JU19 3, -JU22 3 Cooling Fan 4-M5 Screw Holes Power Regeneration Converter Rear View Through Hole ±.5 (Mounting Pitch) 38 Model Number (7.5) (115 ) * 334 (23) Input Voltage Nameplate 4-6 Dia Mounting Hole Diagram Ground Terminal 2-M5 Screws 8±.5 1 (Mounting Pitch) (1) 2 (145) 3 5 (1) * (7) Unit: mm Approx. Mass: 8.3 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Note: Ten digit of : A = Three-phase 2 VAC, D = Three-phase 4 VAC 21

22 Power Regeneration Converter External Dimensions Model: CACP-JU3A3 Power Regeneration Converter Rear View 4-M5 Screw Holes Through Hole ± ±.5 (Mounting Pitch) Mounting Hole Diagram (Mounting Pitch) 38 Model Number Input Voltage Nameplate 4-6 Dia. Ground Terminal 2-M6 Screws (7.5) 38 (1) (115 ) 2 (145) 3 Cooling Fan Heat Sink 5 * (1) (23) * (7) Unit: mm Approx. Mass: 11.5 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Note: Available only for three-phase 2 VAC models. Model: CACP-JU45A3B Power Regeneration Converter Rear View 4-M6 Screw Holes Through Hole 25 2±.5 (Mounting Pitch) Mounting Hole Diagram ± (Mounting Pitch) 38 Model Number Input Voltage Nameplate 4-7 Dia. Ground Terminal 2-M6 Screws (7.5) 38 (25) (115 ) 1 2 (145) 296 Cooling Fan Heat Sink (96) * * (23) (18.5) Unit: mm Approx. Mass: 2. kg 22 * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Note: Available only for three-phase 2 VAC models.

23 Power Regeneration Converter External Dimensions Base-mounted Type Model: CACP-JU15A3BB, -JU19A3BB, -JU22A3BB ±.5 (Mounting Pitch) 4-M5 Screw Holes Power Regeneration Converter Rear View Model Number Input Voltage Ground Terminal 2-M5 Screws 2-6 Dia. (8) ± (Mounting Pitch) 1 8 (1) 1 Mounting Hole Diagram (115 ) (145) (2) Power Regeneration Converter * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Note: Available only for three-phase 2 VAC models. Cooling Fan* Unit: mm Approx. Mass: 11.1 kg Model: CACP-JU3A3BB 46 44±.5 (Mounting Pitch) M5 Screw Holes 13±.5 (Mounting Pitch) 15 Power Regeneration Converter Rear View Model Number Input Voltage Ground Terminal 2-M6 Screws 2-6 Dia. (8) (1) 15 (115 ) (145) (2) Mounting Hole Diagram * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Note: Available only for three-phase 2 VAC models. Cooling Fan* Unit: mm Approx. Mass: 14.6 kg 23

24 Power Regeneration Converter External Dimensions Model: CACP-JU45A3BB ±.5 (Mounting Pitch) 25 4-M6 Screw Holes 2±.5 (Mounting Pitch) 25 Power Regeneration Converter Rear View Model Number Input Voltage Ground Terminal 2-M6 Screws 2-7 Dia. (8) (25) 25 (115 ) (145) (2) Mounting Hole Diagram Cooling Fan* Unit: mm Approx. Mass: 24.9 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Note: Available only for three-phase 2 VAC models. 24

25 MEMO 25

26 SERVOPACK Basic Specifications Basic Specifications Input Power Item Main Circuits + / - Control Power Supply Specifications CACR-JU AE : 27 V to 31 VDC CACR-JU DE : 52 V to 65 VDC 24 VDC Allowable voltage fluctuation: ± 15% Output holding time: 1 ms minimum Power Supply for Fan *1 24 VDC Feedback *2 Pulse encoder (phases A, B, and Z) Main circuit power: Not available (built into power Fuses regeneration converter) Control power: Built in Number of 2 for each axis Channels Analog Monitor (Built-in) *3 USB Communications Sequence Signal External Input Power Input Signals Output Signals Error Signals (Relays) Output Power Range ±1 V (linear range: ±8 V) Response Frequency 1 khz Personal computer Connected Device (application: SigmaWin+ version 5.7 or later, Σ-V-SD component version 1. or later) Communication Standard USB 1.1 compliant, 12 Mbps (full speed support) Functions Status displays, parameter setting, and adjustment function Input Power Voltage 24 VDC ±5% Current Required per Channel 4 ma Number of Channels 14 for each axis (isolated) Number of Channels 14 for each axis (isolated) Maximum Output Current 5 ma Maximum Applicable Voltage 3 V Delay Depends on relay circuit. Number of Channels 1 channel (SPDT contacts) Maximum Load Current 1 A Maximum Applicable Voltage 3 V Continued on next page. 26

27 SERVOPACK Basic Specifications Basic Specifications (cont d) Functions Continued from previous page. Item Specifications External Input Power Voltage 24 VDC ±5% Input Current Required Power per Channel 4 ma Input Number of Signals Channels 2 for each axis (isolated) Number of HWBB 1 for each axis (isolated) Channels Signal Maximum Output 5 ma Output Current Signal Maximum Applicable Voltage 3 V When an HWBB signal is input Output ON when inputs of two channels are OFF. Output Voltage Load Factor Meter V to 1 V Range Output, Speed Meter Output Maximum Output 2 ma Current Allowable Input ±12 V Voltage Analog Speed Input Impedance 6 kω Reference Input Internal Power +15 VDC ±5% Supply Input Power Voltage 24 VDC ±5% 12-bit Digital Reference Input Current Required 4 ma per Channel Number of Motor Winding 1 for each axis Channels Temperature Detection Temperature Sensor NTC thermistor Number of Channels 1ch Output Voltage +24 V Motor Winding Selection Allowable Output 5 ma Current Answerback Function Supported Drive Method Sine-wave current drive with PWM control of IGBT Applicable Motor Model UAK J Overcurrent, overload, main circuit voltage error, Protective Functions heat sink overheating, overspeed, encoder error, CPU error, etc. Control Speed Loop PI control (proportional control), torque limit Standard: Orientation control with a motor encoder Orientation control with an external encoder: Orientation Orientation with an external encoder Orientation control with a magnetic sensor: Orientation with a magnetic sensor Speed Control Range 4 min -1 to motor peak speed Connections between Power Regeneration Converters Local bus Indications CHARGE (orange), RDY (green), ALM (red), one 7-segment LED *1. Needed when using a base mounting unit. For details, refer to page 67. *2. Not available for serial encoder. *3. Do not use an analog monitor signal for system control. Use an analog monitor signal only for adjusting the motor or obtaining data for maintenance purpose. SERVOPACK 27

28 SERVOPACK Basic Specifications Panel Display The SERVOPACK status can be checked on the panel display. Name LED Color Meaning CHARGE Orange Lit when main circuit power is on. Not lit when main circuit power is off. RDY Green Lit when CPU of SERVOPACK works normally. Blink when the digital operator is connected. Not lit when CPU of SERVOPACK not working. ALM Red Lit when alarm occurs. Not lit when no alarm occurs. 7-segment LED Red Shows the status of the SERVOPACK such as alarms. CHARGE Panel Display 7-segment LED ALM RDY SERVOPACK 28

29 SERVOPACK External Dimensions External Dimensions Duct-ventilated Type Model: CACR-JU28AEA, -JU14DEA 4-M5 Screw Holes SERVOPACK Rear View Through Hole (Mounting Pitch) 38 Model Number Input Voltage Nameplate 4-6 Dia (7.5) (135 ) (115 ) Cooling Fan * Heat Sink 334 (23) SERVOPACK ±.5 (Mounting Pitch) Mounting Hole Diagram Ground Terminal M4 Screws 1 3 (1) (1) (145) 3 * CN8 23 (1) 5 4 (5) Unit: mm Approx. mass: 4.4 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. 29

30 SERVOPACK External Dimensions Model: CACR-JU36AEA, -JU18DEA 4-M5 Screw Holes (7.5) Cooling Fan * Heat Sink (23) SERVOPACK Rear View Through Hole ±.5 (Mounting Pitch) 38 Model Number Input Voltage Nameplate (115 ) (135 ) ±.5 (Mounting Pitch) Mounting Hole Diagram 4-6 Dia. Ground Terminal M4 Screws 1 3 (1) (1) (145) 3 * 23 (17) CN8 5 4 (5) Unit: mm Approx. mass: 5.1 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Model: CACR-JU65AEA, -JU33DEA 4-M5 Screw Holes (7.5) Cooling Fan Heat Sink * (23) SERVOPACK Rear View Through Hole ±.5 (Mounting Pitch) Mounting Hole Diagram Model Number Input Voltage Nameplate 4-6 Dia. Ground Terminal M4 Screws 55±.5 1 (Mounting Pitch) 55 (1) (115 ) (135 ) (145) (1) * (7) Unit: mm Approx. mass: 6.5 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. 3

31 SERVOPACK External Dimensions Model: CACR-JU84AEA, -JU12AEA, -JU42DEA, -JU51DEA 4-M5 Screw Holes SERVOPACK Rear View Through Hole 1 13±.5 (Mounting Pitch) ±.5 (Mounting Pitch) Mounting Hole Diagram 38 Model Number Input Voltage Nameplate 4-6 Dia. Ground Terminal M5 Screws 1 17 (2) (7.5) (1) (135 ) (115 ) 5 2 (145) 3 Cooling Fan Heat Sink * (1) * (7) (23) Unit: mm Approx. mass: 11.9 kg SERVOPACK * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Model: CACR-JU125AEA SERVOPACK Rear View 4-M5 Screw Holes Through Hole ±.5 (Mounting Pitch) ±.5 (Mounting Pitch) Mounting Hole Diagram Model Number Input Voltage Nameplate 4-6 Dia. Ground Terminal M5 Screws 1 17 (2) (7.5) (1) (7.5) (135 ) (115 ) (145) 2 3 Cooling Fan 5 * (1) * Heat Sink (7) (23) * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. Unit: mm Approx. mass: 12.1 kg 31

32 SERVOPACK External Dimensions Model: CACR-JU196AEA SERVOPACK Rear View 4-M6 Screw Holes Through Hole 25 2±.5 (Mounting Pitch) Mounting Hole Diagram ±.5 (Mounting Pitch) Model Number Input Voltage 4-7 Dia. Ground Terminal M6 Screws (2) (7.5) 38 (25) (135 ) (115 ) 1 2 (14) 296 Cooling Fan Heat Sink * * (96) (23) (18.5) Unit: mm Approx. mass: 2.1 kg * The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink. 32

33 SERVOPACK External Dimensions Base-mounted Type Model: CACR-JU28AEAB Dia (2.4) M5 Screw Holes ±.5 (Mounting Pitch) Power Regeneration Converter Rear View Model Number Input Voltage Ground Terminal 1 3 ±.5 M4 Screws 5 (Mounting Pitch) Mounting Hole Diagram (1) (8) (115 ) (145) (135 ) (2) SERVOPACK Cooling Fan* Unit: mm Approx. Mass: 7.1 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Model: CACR-JU36AEAB 12 4-M5 Screw Holes 2-6 Dia ±.5 (Mounting Pitch) Power Regeneration Model Converter Rear View Number Input Voltage 4-6 Dia ±.5 5 (Mounting Pitch) Mounting Hole Diagram Ground Terminal M4 Screws Cooling Fan* Unit: mm Approx. Mass: 7.8 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. 33

34 SERVOPACK External Dimensions Model: CACR-JU65AEAB ±.5 (Mounting Pitch) 4-M5 Screw Holes Power Regeneration Converter Rear View 1 55±.5 (Mounting Pitch) 75 Mounting Hole Diagram 2-6 Dia. Model Number Input Voltage Ground Terminal M4 Screws Cooling Fan * 15 Unit: mm Approx. Mass: 9.2 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Model: CACR-JU84AEAB, -JU12AEAB 12 4-M5 Screw Holes 2-6 Dia Power Regeneration Converter Rear View ±.5 (Mounting Pitch) Model Number Input Voltage Ground Terminal M5 Screws 1 13±.5 (Mounting Pitch) 15 Mounting Hole Diagram Cooling Fan * Unit: mm Approx. Mass: 15.4 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. 34

35 SERVOPACK External Dimensions Model: CACR-JU125AEAB ±.5 (Mounting Pitch) 4-M5 Screw Holes 2-6 Dia. Power Regeneration Converter Rear View Model Number Input Voltage ±.5 (Mounting Pitch) 15 Mounting Hole Diagram Ground Terminal 2-M6 Screws SERVOPACK Cooling Fan * Unit: mm Approx. Mass: 15.6 kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. Model: CACR-JU196AEAB M6 Screw Holes 2-7 Dia ±.5 (Mounting Pitch) Power Regeneration Converter Rear View Model Number Input Voltage ±.5 (Mounting Pitch) 25 Ground Terminal M6 Screws Mounting Hole Diagram Cooling Fan* Unit: mm Approx. Mass: 25. kg * The power supply for a cooling fan (24 VDC) is not provided by Yaskawa. 35

36 Installation Spindle Motor The service life of the spindle motor will be shortened or unexpected problems will occur if the spindle motor is installed incorrectly or in an inappropriate location. Always observe the following installation instructions. Installation Environment Item Surrounding Air Temperature Surrounding Air Humidity Installation Site Storage Environment C to 4 C (no freezing) 2% to 8%RH (no condensation) Condition Indoor, free of corrosive or explosive gases Well-ventilated and free of dust and moisture Facilitates inspection and cleaning. Elevation:1, m max. Free of high magnetic field Free of oil Store the motor in the following environment if it is stored with the power cable disconnected. Ambient temperature during storage: 2 C to 6 C (no freezing) Ambient humidity during storage: 2% to 8%RH (no condensation) CAUTION Provide sufficient space so that cooling air will be provided to the cooling fan. Keep a space of at least 1 mm between the machine and the ventilation outlet of the motor. If ventilation is not proper, the motor temperature fault protective function will work regardless of whether or not the load is at the rated value or not. Install the motor in a clean location free from oil mist and water drops. If the motor is likely to come in contact with water or oil, protect the motor with a cover. The intrusion of water or dirty oil into the interior of the motor will decrease the insulation resistance, which may result in a ground fault. Check that the mounting bed, base, or stand of the motor is of robust construction because the weight of the motor as well as the dynamic load of the motor in operation will be imposed on it, possibly causing vibration. Use seal connectors, conduits, or similar devices to seal the cable openings of the motor terminal box. Failure to observe this caution may result in cuttings, cutting oil mist, or other foreign matter entering the motor through the cable opening, possibly causing malfunction. When vertically mounting the motor with the shaft on the bottom, the motor shaft must not touch the stand, the ground, or other surfaces. If the shaft touches these surfaces, the shaft is pushed into the motor and the bearing may be damaged. 36

37 Installation Spindle Motor Enclosure The protective structure of the spindle motor when the special cable is used provides IP44 protection. However, this does not apply to the shaft opening. (Refer to the following figure.) If you need to use the motor in a location where oil will come into contact with the shaft opening, contact a Yaskawa sales representative. Flange Shaft opening This refers to the gap where the shaft protrudes from the end of the motor. Shaft Installation Orientation Flange type Mount the motor with the motor shaft on the load side at any angle between horizontal and the downward vertical direction. If the motor shaft is facing up, excessive force will be imposed on the motor shaft. As a result, the service life of the motor will be adversely affected. Use the spindle motor UAKAJ-45 or UAKBJ-3 (outer diameter 38) with the terminal box facing upward and the motor shaft facing horizontal. If the terminal box is in the horizontal or downward direction, dust may intrude from the ventilation mouth on the bottom of the load-side bracket. As a result, the motor may fail to operate or unexpected accidents may occur. Installation Foot-mounted type Mount the legs on the floor. If the legs are installed upward, excessive force will be imposed on the legs. As a result, the service life of the spindle motor will be adversely affected. 37

38 Installation Spindle Motor Coupling Motor and Machinery Consider the following conditions when coupling the spindle motor with the machinery. Direct Coupling Couple the motor with the machinery so that the center of the motor shaft and that of the machinery shaft are on a straight line. Insert a liner for adjustment, if necessary. Install the motor so that alignment accuracy falls within the following range. Vibration that will damage the bearings and encoders if the shafts are not properly aligned. Important Coupling * B Level * : Alignment Accuracy Measurement Method Tolerance A Surface irregularity B Allowable Value.3 mm max..3 mm max. * A Note: Turn together with coupling. Do not allow any direct impact to the shafts when installing the couplings. Do not hit the area near encoders with a hammer etc., as impacts may damage the encoders. Before installation, thoroughly remove the anticorrosive paint from the flange surface and the end of the motor shaft. Only after removing the paint can motors be installed on the machines. Anticorrosive paint is coated here. 38

39 Installation Spindle Motor Belt Coupling Check that the motor shaft is parallel to the machinery shaft and that the line connecting the centers of the pulleys and the shafts are at right angles to each other. If the angularity of the belt is improper, the belt will vibrate or slip. The radial load imposed on the motor shaft edge must not exceed the permissible value. If an excessive radial load is imposed on the motor shaft, the motor bearings will be adversely affected and the service life of the bearings will be decreased. For details, refer to Tolerance Radial Loads (page 14). Be sure that no axial load is imposed on the motor shaft. Make sure that the contact angle of the belt with the pulley is 14 or more. If not, the belt may slip. d C Belt If C is 1, mm or less, d < 1 mm. If C is more than 1, mm, d/c < 1/1. β < 1/3 Contact angle φ > 14 β Installation C φ Machinery shaft Motor shaft Belt Installation Gear Coupling Check that the motor shaft is parallel to the machinery shaft and that the centers of the gears are engaged properly. Refer to Tolerance Radial Loads (page 14) for the precision of the peripheral parts connecting to the motor shaft. The gears may grate if they do not engage properly. Be sure that no axial load is imposed on the motor shaft. Mounting a Pulley or Gear to the Motor Shaft When mounting a pulley or gear to the motor shaft, consider the mounting balance of the motor. The dynamic balance of the motor is kept with a half key (for motors with a keyway), which is a half as thick as the key (T) specified in the motor shaft dimensional drawing. The motor rotates at high speed and a little imbalance in the mechanism may cause the motor to vibrate. 39

40 Installation Σ-V-SD Driver (Power Regeneration Converter and SERVOPACK) Σ-V-SD Driver (Power Regeneration Converter and SERVOPACK) Installation Requirements Item Specifications Surrounding Air Temperature C to 4 C: at 1% load C to 55 C: at 7% load Storage Temperature 2 C to 85 C Surrounding Air Humidity and 9%RH or less (with no freezing or condensation) Storage Humidity Vibration Resistance 4.9 m/s 2 Shock Resistance 19.6 m/s 2 Protection Class IP1 An environment that satisfies the following conditions. Free of corrosive or flammable gases Pollution Degree 2 Free of exposure to water, oil, or chemicals Free of dust, salts, or iron dust Altitude 1 m or less Others Free of static electricity, strong electromagnetic fields, magnetic fields or exposure to radioactivity Thermal Design of Control Panel Install the Σ-V-SD drivers, host controllers, and other units in a control panel. Use a control panel with an enclosed structure that provides protection against corrosive gases, water, and oil. Also, design the system so that the temperature rise in the control panel does not cause the temperature to exceed the surrounding air temperature. Calorific Value Power Regeneration Converter Calorific Value at Continuous Rated Operation Model Loss of Control Loss of Power Block (W) Total (W) Block (W) Total Inside Duct CACP-JU15A CACP-JU19A CACP-JU22A CACP-JU3A CACP-JU45A3B CACP-JU15D CACP-JU19D CACP-JU22D

41 Installation Σ-V-SD Driver (Power Regeneration Converter and SERVOPACK) SERVOPACK Calorific Value at Continuous Rated Operation Model Loss of Control Loss of Power Block (W) Total (W) Block (W) Total Inside Duct CACR-JU28AEA CACR-JU36AEA CACR-JU65AEA CACR-JU84AEA CACR-JU12AEA CACR-JU125AEA CACR-JU196AEA CACR-JU14DEA CACR-JU18DEA CACR-JU33DEA CACR-JU42DEA CACR-JU51DEA Installation Precautions Precautions for installing the Σ-V-SD driver are given below. Always secure the Σ-V-SD driver on a vertical surface using screws or bolts. Provide the specified space on the left, right, top, and bottom of the driver to enable maintenance and ventilation. For details, refer to Installation Orientation and Space (page 42). Installation Duct-ventilated type Place the heat sink of the Σ-V-SD driver outside of the ventilation ducts to allow external air flow through the heat sink. The loss from the control panel will be reduced, and the majority of the loss from the unit will be cooled directly by the external air. Cooling the heat sink requires an air flow of 2.5 m/s in the ventilation duct. Make sure that cooling air flows through the heat sink for each Σ-V-SD driver. We recommend a metal cooling fan. Plastic fans will deteriorate when exposed to cutting oil, which may cause Σ-V-SD driver failure or other problems. Flow of the external air Cooling fan Ventilation duct Heat sink Unit Flow of the external air Σ-V-SD Driver Installation Base-mounted Type Since the duct is inside in the control panel, refer to the column containing total values for the Loss of Power Block in the Power Regeneration Converter and SERVOPACK tables on pages

42 Installation Σ-V-SD Driver (Power Regeneration Converter and SERVOPACK) Installation Orientation and Space Precautions for the mounting the Σ-V-SD driver, including the mounting orientation and mounting space, are given below. Note: The figure is an example of a duct-ventilated type driver. Dimensions for base-mounted type drivers are the same (ventilation duct is not required). Max: 5 mm Max: 5 mm Max: 5 mm Min: 5 mm Min: 5 mm Σ-V-SD Driver Min: 12 mm Air Flow Ventilation Duct Fan Heat Sink Min: 5 mm Min: 12 mm Installation Orientation and Space for Σ-V-SD Driver Cooling Air Min: 2.5 m/s Always install the power regeneration converter on the left side of the SERVOPACK. Refer to the external dimension diagrams for external dimensions and mounting dimensions of the products. Make sure that the ambient air temperature of the Σ-V-SD driver is C to 55 C near the heat sink and inside the control panel at a 7% load, and C to 4 C near the heat sink and inside the control panel at a 1% load. To prevent oil penetration, seal the mounting screw sections of the power regeneration converter and the SERVOPACK. Always install the Σ-V-SD driver with the fan at the top to ensure efficient cooling. When mounting the Σ-V-SD driver, allow space above and below it to prevent heat buildup. When stirring the air inside the control panel, do not allow the airflow to fall directly on the Σ-V-SD driver to prevent dirt from collecting on the Σ-V-SD driver. Provide the following spaces between the units. 42

43 Installation Σ-V-SD Driver (Power Regeneration Converter and SERVOPACK) Unit: mm 2.5 ±.3 (.5) 1 1 Mounting hole Mounting hole Unit Unit Installation 43

44 Selecting Cables System Configurations Power supply Three-phase 2/4 VAC R S T Host controller Standard (Orientation Control with a Motor Encoder) Molded-case circuit breaker I/O Door sensor Power regeneration converter Local bus CN 5 CN 1 SERVOPACK CN 5A CN12 CN2 Noise filter Magnetic contactor Machine Open Safety door (Example) Emergency stop CN1 Control power supply (24 VDC) CN7A CN7B P/ + CN3 N/ - Digital operator Main circuit power supply L1 L2 L3 24 VDC PN bus bar (built-in) CN7A U V W CN 4 CN 3 Personal computer AC reactor Motor encoder Magnetic contactor for winding selection Spindle motor For the other orientation control, see the connection examples on the next page. 44

45 Selecting Cables System Configurations Orientation Control with an External Encoder Orientation Control with a Magnetic Sensor SERVOPACK CN 1 CN 5A CN12 CN2 CN9 SERVOPACK CN 1 CN 5A CN12 CN2 CN1 CN 4 CN 4 CN7A CN 3 Personal computer CN7A CN 3 Personal computer U V W U V W Motor encoder Motor encoder Magnetic contactor for winding selection Magnetic contactor for winding selection Spindle motor Transmission (gear, belt) Timingbelt 1:1 External encoder Main shaft Spindle motor Transmission (gear, belt) Magnet Magnetic sensor Main shaft Selecting Cables 45

USER S MANUAL. AC Servo Drives -V-SD Series. Speed Reference with Analog Voltage Expanded Functions

USER S MANUAL. AC Servo Drives -V-SD Series. Speed Reference with Analog Voltage Expanded Functions AC Servo Drives -V-SD Series USER S MANUAL Speed Reference with Analog Voltage Expanded Functions CACR-JU E SERVOPACK CACP-JU 3 Power Regeneration Converter UAK J- CZ Spindle Motor Outline Compatible Devices

More information

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001 C SERVO DRIVES SERIES Rotary Servomotors Certified for ISO91 and ISO141 JQ-422 JQ-EM22 CONTENTS Rotary Servomotors SGMMV (ow Inertia, Ultra-small Size) 4 SGM7J (Medium Inertia, High-speed) 14 SGM7 (ow

More information

Troubleshooting Alarm Displays Warning Displays

Troubleshooting Alarm Displays Warning Displays 10 10.1 Alarm Displays............................................10-2 10.1.1 List of Alarms...................................................... 10-2 10.1.2 of Alarms............................................

More information

(For Rotary Servomotors)

(For Rotary Servomotors) MECHATROLINK-III Communications Reference SERVOPACKs SGDV- E2 (For Rotary Servomotors) Designations S G D V - 2R9 E 2 A 002 00 0 v Series SGDV SERVOPACKs with DC Power Input st+2nd+ 3rd digits 4th digit

More information

Troubleshooting Alarm Displays Warning Displays

Troubleshooting Alarm Displays Warning Displays 9 9.1 Alarm Displays..............................................9-2 9.1.1 List of Alarms........................................................ 9-2 9.1.2 of Alarms..............................................

More information

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001 AC SERVO DRIVES SERIES Servopacks Certified for ISO9001 and ISO14001 JQA-0422 JQA-EM0202 CONTENTS SERVOPACKs Single-axis Analog Voltage/Pulse Train Reference SERVOPACKs 326 Single-axis MECHATROLINK-II

More information

New Servo Concept: Junma

New Servo Concept: Junma New Servo Concept: Junma Junma uses the world s premier servo technology to provide unmatched performance with a quick and efficient setup. This totally new plug and play design concept requires no parameter

More information

Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B

Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B Analog Voltage/Pulse Train Reference Type SERVOPACKs SGDV- 0 (For Rotary Servomotors) SGDV- 05 (For Linear Servomotors) Model Designations SGDV - R70 A 0 B 002000 Options 002000 Base-mounted, varbish(standard)

More information

Drive Safety integrated AC servo amplifier <MR-J3- S 0.1kW to 55kW> Safety logic unit <MR-J3-D05>

Drive Safety integrated AC servo amplifier <MR-J3- S 0.1kW to 55kW> Safety logic unit <MR-J3-D05> General-Purpose AC Servo MELSERVO-J3 Drive Safety integrated AC servo amplifier Safety logic unit The MR-J3- S Drive Safety integrated AC servo amplifier (SSCNET Ⅲ

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

AC SERVO DRIVES JUNMA SERIES D E F I JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA

AC SERVO DRIVES JUNMA SERIES D E F I JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA AC SERVO DRIVES JUNMA SERIES Pulse Reference Type Mechatrolink-II Network Type GB D E F I JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA New Servo Concept JUNMA Contents Page 2 About YASKAWA New Servo

More information

Σ-V Series USER'S MANUAL Setup Rotational Motor

Σ-V Series USER'S MANUAL Setup Rotational Motor AC Servo Drives Σ-V Series USER'S MANUAL Setup Rotational Motor SGDV SERVOPACK SGMJV/SGMAV/SGMPS/SGMGV/SGMSV/SGMCS Servomotors 1 2 3 4 Overview of Setup Installation Wiring and Connection Safety Function

More information

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications Rotary s Designations 2Without Gears - 0 D 2 Series st+2nd digits 3rd digit 4th digit 5th digit 6th digit 7th digit st+2nd digits Rated Output 5th digit Design Revision Order 7th digit Options Code 5 50

More information

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit.

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit. Rotary s Designations 2Without s - D 2 Series st+2nd s rd 4th th th 7th st+2nd s Rated Output th Design Revision Order 7th Options Code W W C2 W 2 2 W 4 4 W W 8 7 W rd Power Supply Voltage Code th Code

More information

LARGE-CAPACITY SERIES

LARGE-CAPACITY SERIES AC SERVO DRIVES LARGE-CAPACITY SERIES V to 37 kw 4 V to 55 kw Servomotor SGMVV SERVOPACK SGDV Certified for ISO9 and ISO4 JQA-4 JQA-EM Strongest line-up ever! Newest servo drives increase speeds & improve

More information

Troubleshooting Alarm Displays Warning Displays

Troubleshooting Alarm Displays Warning Displays 8 8.1 Alarm Displays..............................................8-2 8.1.1 List of Alarms........................................................ 8-2 8.1.2 of Alarms..............................................

More information

GE Fanuc Automation. Servo Motor β Series. Computer Numerical Control Products. Descriptions Manual

GE Fanuc Automation. Servo Motor β Series. Computer Numerical Control Products. Descriptions Manual GE Fanuc Automation Computer Numerical Control Products Servo Motor β Series Descriptions Manual GFZ-65232EN/03 December 2002 Warnings, Cautions, and Notes as Used in this Publication GFL-001 Warning Warning

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) F Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

Integrated servo motor

Integrated servo motor R88E-AECT@, R88S-EAD@ Integrated servo motor Motor and drive integrated for space optimization Wide range of motors from 2.55 Nm to 25 Nm 3000 rpm rated speed Peak torque 300% of rated torque IP65 protection

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Σ-V Series USER'S MANUAL Setup Rotational Motor

Σ-V Series USER'S MANUAL Setup Rotational Motor AC Servo Drives Σ-V Series USER'S MANUAL Setup Rotational Motor SGDV SERVOPACK SGMJV/SGMAV/SGMPS/SGMGV/SGMSV/SGMCS Servomotors 1 2 3 4 1 Overview of Setup Installation Wiring and Connection Safety Function

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) 0A PC board type 0A TM type 60A Screw terminal type 80A Connector type 300A Connector type FEATURES. High-, high-current

More information

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit. Rotary s Model Designations - mini Series st+nd digits 3rd digit th digit th digit 6th digit 7th digit st+nd digits Rated Output th digit Design Revision Order 7th digit Options Code Code Code B3 3.3 W

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) A PC board type A TM type 60A Screw terminal type 80A Connector type 300A Connector type Compliance with RoHS Directive

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

UMK M A A. RoHS-Compliant. 2-Phase Stepping Motor and Driver Package. Features. Product Number Code. Product Line

UMK M A A. RoHS-Compliant. 2-Phase Stepping Motor and Driver Package. Features. Product Number Code. Product Line RoHS-Compliant Stepping Motor and Package UMK Series Additional Information Technical reference Page F- The UMK Series is a -phase stepping motor (resolution: per rotation) with easy-handling AC input

More information

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order Rotary s Model Designations - 3 D Series st+nd digits 3rd digit th digit th digit th digit 7th digit st+nd digits Rated Output th digit Serial Encoder 7th digit Options Code 3 3 W W 9 8 W 3.3 kw.8 kw 3.9

More information

Sigma II Series Servo System User s Manual

Sigma II Series Servo System User s Manual Sigma II Series Servo System User s Manual WARNING YASKAWA manufactures component parts that can be used in a wide variety of industrial applications. The selection and application of YASKAWA products

More information

RDrive 85 servo motors. User manual

RDrive 85 servo motors. User manual INTRODUCTION Rozum Robotics has designed its RDrive (RD) servo motors to enable precision motion control in industrial and commercial applications. This manual is intended for technicians and engineers

More information

4th digit. 7th digit. digits. Specifications. Interface. MECHATROLINK-2 communications Reference Type (for rotary servomotors)

4th digit. 7th digit. digits. Specifications. Interface. MECHATROLINK-2 communications Reference Type (for rotary servomotors) MECHATROLINK- Communications Reference Type PACKs SGDV- (For Rotary Servomotors) SGDV- 5 (For Linear Servomotors) Model Designations S G D V - R70 A A 000 00 0 v Series SGDV PACK st+nd+ rd digits 4th digit

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) D Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK

Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK YASKAWA YASKAWA MANUAL NO. SIE-S800-32.4 Copyright 2002 YASKAWA ELECTRIC CORPORATION All rights reserved.

More information

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information. / Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance

More information

(For Linear Servomotors) S G D V - R70 A 21 A th digit. 7th digit. 5th6th digits

(For Linear Servomotors) S G D V - R70 A 21 A th digit. 7th digit. 5th6th digits MECHATROLINK- Communications Reference Type PACKs SGDV- (For Rotary Servomotors) SGDV- 5 (For Linear Servomotors) Designations S G D V - R70 A A 000 00 0 v Series SGDV PACK st+nd+ rd digits 4th digit 5th6th

More information

MR-J3 Servomotors and Amplifiers

MR-J3 Servomotors and Amplifiers MR-J3 Servomotors and Amplifiers With a capacity range of 5W to 55kW, we reduced the size of both the amplifier and motor, added a high resolution encoder and advanced auto-tuning and vibration control.

More information

Cable lead-out. Standard. Rear lead-out (Connecter used in models 58 and 65) Variation. Side lead-out is available. (Models 25, 32, and 40) Option

Cable lead-out. Standard. Rear lead-out (Connecter used in models 58 and 65) Variation. Side lead-out is available. (Models 25, 32, and 40) Option SHA Series The SHA series comprises AC servo actuators that integrate a thin speed reducer HarmonicDrive for precision control and a super flat AC servo motor. The SHA series features an unmatched compact

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

(For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B Voltage Interface 100 VAC 200 VAC 400 VAC V (Three Phase)

(For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B Voltage Interface 100 VAC 200 VAC 400 VAC V (Three Phase) MECHATROLINK-III Communications Reference Type s SGDV- (For Rotary Servomotors) SGDV- (For Linear Servomotors) Designations SGDV - R70 A 0 B 00000 Options vseries SGDV Code 00000 Base-mounted, varbish(standard)

More information

USER S MANUAL. OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw)

USER S MANUAL. OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw) USER S MANUAL OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw) Thank you for choosing this OMNUC U-series product. Proper use and handling

More information

JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA AC SERVO DRIVES JUNMA SERIES. Goodwin Electronics: Tel: Web:

JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA AC SERVO DRIVES JUNMA SERIES. Goodwin Electronics: Tel: Web: AC SERO DRIES JUNMA SERIES PULSE REFERENCE TYPE MECHATROLINK-II NETWORK TYPE EN DE ES FR IT JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA New Servo Concept JUNMA Contents Page 2 About YASKAWA New Servo

More information

TH450A-T TH550A-T THP550-T/TS3000

TH450A-T TH550A-T THP550-T/TS3000 0 TH450A-T TH550A-T THP550-T/TS3000 INSTRUCTION MANUAL CEILING TYPE (OVERHEAD TRAVELING TYPE) INDUSTRIAL ROBOT SPECIFICATIONS Notice 1. Make sure that this instruction manual is delivered to the final

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

Power Regenerative Converter, THYFREC CV240S

Power Regenerative Converter, THYFREC CV240S Development of New Products Power Regenerative Converter, THYFREC CV240S Harmonic restraint, Power regeneration, 120 conduction, Power factor improvement, Common converter system, Environment compatibility

More information

Servo Motors B-9. Overview. Tuning-Free NX. Tuning-Free NX Series. Servo Motors. Accessories. Page. NX Series B-10 B-9

Servo Motors B-9. Overview. Tuning-Free NX. Tuning-Free NX Series. Servo Motors. Accessories. Page. NX Series B-10 B-9 Servo Motors B-9 Overview NX Servo Motors Accessories Page B-1 B-9 B-1 Servo Motor and Driver Package Technical reference Page H-1 Regulations & Standards Page I-2 For detailed

More information

MR-J4-_B-RJ010 MR-J4-_B4-RJ010 MR-J3-T10 SERVO AMPLIFIER INSTRUCTION MANUAL. General-Purpose AC Servo

MR-J4-_B-RJ010 MR-J4-_B4-RJ010 MR-J3-T10 SERVO AMPLIFIER INSTRUCTION MANUAL. General-Purpose AC Servo General-Purpose AC Servo CC-Link IE Field Network interface with Motion MODEL (Servo amplifier) MR-J4-_B-RJ010 MR-J4-_B4-RJ010 MODEL (CC-Link IE Field Network interface unit) MR-J3-T10 SERVO AMPLIFIER

More information

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AV-300i Specifications. Saftronics Inc.  PC10 Product Specifications PC10. Mini Vector AC Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications PC10 Product Specifications PC10 Mini Vector AC Drive 1 (1) T hree-phas e 230V input Drive Hp 1/8 1/4 1/2 1 2 3 5 7.5 10 Nominal applicable

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

4th digit. 5th+6th digits. 7th digit. Specifications. 8th+9th+10th digits Options (hardware)* 4. Interface

4th digit. 5th+6th digits. 7th digit. Specifications. 8th+9th+10th digits Options (hardware)* 4. Interface MECHATROLINK- Communications Reference Type PACKs SGDV- (For Rotary Servomotors) SGDV- 5 (For Linear Servomotors) Designations S G D V - R70 A A 000 00 0 v Series SGDV PACK st+nd+ rd digits 4th digit 5th+6th

More information

Specifications of ASDA A2-E_220V Series

Specifications of ASDA A2-E_220V Series Specifications of ASDA A2-E_220V Series Power Supply 100W 200W 400W 750W 1kW 1.5kW 2kW 3kW ASDA A2-E Series 01 02 04 07 10 15 20 30 Phase / Voltage Three-phase / Single-phase 220VAC Three-phase 220VAC

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features. The RBK Series is a motor and driver package

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features. The RBK Series is a motor and driver package Stepping Motors RoHS-Compliant Stepping Motor and Package RBK Series dditional Information Technical reference Page F-1 Safety standards Page G- The RBK Series is a motor and driver package (Terminal box

More information

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features

RoHS-Compliant 2-Phase Stepping Motor and Driver Package RBK Series. Features Stepping s RoHS-Compliant -Phase Stepping and Package RBK Series dditional Information Technical reference Page F- Safety standards Page G- The RBK Series is a motor and driver package consisting of a

More information

56 mm sq. (2.20 inch sq.)

56 mm sq. (2.20 inch sq.) 56 mm sq. (. inch sq.) 1.8 /step RoHS Unipolar winding, Lead wire type Bipolar winding, Lead wire type p. 7 Customizing Hollow Shaft modification Decelerator Encoder Varies depending on the model number

More information

SGDS Sigma III Servo Amplifier User Manual for Mechatrolink-II Communications

SGDS Sigma III Servo Amplifier User Manual for Mechatrolink-II Communications SGDS Sigma III Servo Amplifier User Manual for Mechatrolink-II Communications Copyright 2004 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a

More information

MR-J4-DU_B_-LL SERVO AMPLIFIER INSTRUCTION MANUAL

MR-J4-DU_B_-LL SERVO AMPLIFIER INSTRUCTION MANUAL General-Purpose AC Servo SSCNET /H Interface AC Servo for Pressure Control MODEL (SERVO AMPLIFIER) MR-J4-_B_-LL MODEL (DRIVE UNIT) MR-J4-DU_B_-LL SERVO AMPLIFIER INSTRUCTION MANUAL Safety Instructions

More information

SGDV- E5 (For Linear Servomotors)

SGDV- E5 (For Linear Servomotors) PACKs with Additional Options SGDV- E (For Rotary Servomotors) SGDV- E5 (For Linear Servomotors) Model Designations SGDV- R70 A E A 000 00 0 v Series SGDV PACK Current Voltage 00 V 400 V Code Applicable

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

4th digit. 5th digit. 6th digit. Code Specifications. Design Revision Order. Code Specifications. Standard. Code Specifications

4th digit. 5th digit. 6th digit. Code Specifications. Design Revision Order. Code Specifications. Standard. Code Specifications Rotary s Model Designations - D Series st+nd digits 3rd digit th digit th digit th digit 7th digit st+nd digits Rated Output Code Specifications. kw. kw. kw. kw 3 3. kw. kw. kw 7 7. kw : vailable only

More information

60 mm sq. (2.36 inch sq.)

60 mm sq. (2.36 inch sq.) 6 mm sq. (.36 inch sq.) 1.8 /step RoHS Unipolar winding, Connector type Unipolar winding, Dimensions for attaching NEMA3 are interchangeable (47.14 mm-pitch) Bipolar winding, Connector type p. 76 Bipolar

More information

IP65 Splash and Dust Proof Stepping Motors

IP65 Splash and Dust Proof Stepping Motors IP5 Splash and Dust Proof Stepping Motors CE/UL Model Features These IP5 rated motors* have superior water and dust resistance, and can be safely utilized in harsh or wet environments such as in food processing

More information

VECTOR-CONTROLLED INVERTER DRIVES WITH POWER REGENERATIVE FUNCTION FOR MACHINE TOOLS VARISPEED-626M5/656MR5 USER'S MANUAL

VECTOR-CONTROLLED INVERTER DRIVES WITH POWER REGENERATIVE FUNCTION FOR MACHINE TOOLS VARISPEED-626M5/656MR5 USER'S MANUAL VECTOR-CONTROLLED INVERTER DRIVES WITH POWER REGENERATIVE FUNCTION FOR MACHINE TOOLS VARISPEED-626M5/656MR5 USER'S MANUAL INVERTER (VS-626M5) 200V CLASS 3.7/2.2 TO 37/30kW(5/3 TO 50/40HP) CONVERTER (VS-656MR5)

More information

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY EV RELAYS (AEV) 80A A 0A FEATURES. High-, high-current control possible 0 high- switching cutoff has been achieved thanks to a sealed construction

More information

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters. ~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

Optical encoder MEC22 HR

Optical encoder MEC22 HR Optical encoder MEC22 HR Description The MEC22 HR is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square

More information

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model 60-mm-dia. Encoder Rugged Encoder for High-precision Detection of Automatic Machine Timing Rugged construction with the highest shaft loading. Radial: 120 N, Thrust: 50 N IP65f water- and oil-proof construction.

More information

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation.

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation. 1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation. 2. With a wide variety of models and advanced functions available, these bearings

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

USER'S MANUAL Design and Maintenance

USER'S MANUAL Design and Maintenance AC Servo Drives DC Power Input Σ-V Series USER'S MANUAL Design and Maintenance Rotational Motor MECHATROLINK-III Communications Reference SGMMV Servomotor SGDV SERVOPACK Outline SigmaWin+ Wiring and Connection

More information

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-4797575 Fax : 011-4797574 E-mail : sales@ashalain.com Absolute 60-mm-dia.

More information

Product Data Sheet 3252J/2H3PU

Product Data Sheet 3252J/2H3PU 3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3

More information

This section is specifically about safety matters

This section is specifically about safety matters 6 4 ) 1 6 4 1 -, 1 8-4 6-4 1 6 4 7 + 6 1 ) 7 ) 4 ) 6 1-6 6-4. 4. 0 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information and precautions

More information

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80

More information

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000 Incremental 60-mm-dia. Rotary Encoder E6F-C The Strongest Shaft for Tough Jobs The strongest shaft of any OMRON Incremental Encoder (120 N in the radial direction and 50 N in the thrust direction). Water-

More information

This section is specifically about safety matters

This section is specifically about safety matters 6 4 ) 5 1 5 6 4 1 -, 1 8-4 6-4 1 5 6 4 7 + 6 1 ) 7 ) 5 2 - -,, - 6 - + 6 4. 4. 2 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information

More information

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. YASKAWA DUAL ENCODER (PG) FEEDBACK CARD (PG-Z) INSTRUCTIONS Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. Package Contents:

More information

DS2 series servo drive

DS2 series servo drive DS2 series servo drive Manual WUXI XINJE ELECTRIC CO., LTD. Data No.: SC209 20110412 1.0 2 Safety notes Confirmation Do not use the drivers that are broken, lack of parts or wrong types. Installation Make

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

Lexium integrated drives

Lexium integrated drives Description ILp for CANopen, PROFIBUS DP, RS ILA with AC synchronous servo motor Description ILA comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and an AC synchronous

More information

Magnetic Encoder MEM 22

Magnetic Encoder MEM 22 Description The MEM 22 is a magnetic incremental encoder. He is a reliable low cost hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder MEM22 is designed

More information

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Ultraminiature Photoelectric Switches with Self-contained Amplifier Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features Page 1 of 8 Description The MA3 is a miniature rotary absolute shaft encoder that reports the shaft position over 360 with no stops or gaps. The MA3 is available with an analog or a pulse width modulated

More information

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface... Instruction Leaflet IL04801003E Effective March 2013 HMi VU Series Instruction Leaflet Contents Description... Page Preface... 1 Safety Precautions... 1 Installation... 3 Wiring... 4 asic Inspection...

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view) Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting

More information

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation 44 PHOTO PHOTO Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F- Glossary of terms... P.549~ guide... P.49~ General precautions...p.55~ Recognition Make sure to use

More information

OMNUC U SERIES MODELS R88M-U (AC Servomotors) MODELS R88D-UP (AC Servo Drivers) USER S MANUAL. AC SERVOMOTORS/DRIVERS (30 to 750-W Pulse-train Inputs)

OMNUC U SERIES MODELS R88M-U (AC Servomotors) MODELS R88D-UP (AC Servo Drivers) USER S MANUAL. AC SERVOMOTORS/DRIVERS (30 to 750-W Pulse-train Inputs) Cat. No. I502-E1-5 USER S MANUAL OMNUC U SERIES MODELS R88M-U (AC Servomotors) MODELS R88D-UP (AC Servo Drivers) AC SERVOMOTORS/DRIVERS (30 to 750-W Pulse-train Inputs) Thank you for choosing this OMNUC

More information

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications The Micro 100 Drives have been designed with a Pulse Width Modulated (PWM) regulator to produce clean DC current to

More information

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available.

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available. Function The 3G3HV High-capacity General-purpose Inverter is an easy-to-use inverter that has advanced features, such as PID control and energy-saving operations. SYSDRIVE 3G3HV Inverter Models The following

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

SX (400V) System configuration

SX (400V) System configuration ~ ~ SX (400V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

IP Series DUAL POWER AMPLIFIERS

IP Series DUAL POWER AMPLIFIERS OPERATING INSTRUCTIONS IP Series DUAL POWER AMPLIFIERS IP-600D IP-450D IP-300D TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 4 3. FEATURES... 4 4. HANDLING PRECAUTIONS... 4 5.

More information

AD Series. AC Servo Drive. For the highest requirements in performance and precision

AD Series. AC Servo Drive. For the highest requirements in performance and precision Range of Performance.1 kw 7 kw (.32 33.4 ) Drastically Reduced Motor Cogging Torque Advanced Drive Technology Autotuning Built-in Programmable Sequence with max. 512 program steps and 1 positions Plug

More information

Scroll down to view your document!

Scroll down to view your document! Over 100 years cumulative experience 24 hour rush turnaround / technical support service Established in 1993 The leading independent repairer of servo motors and drives in North America. Visit us on the

More information

SX (400 V) System configuration

SX (400 V) System configuration ~ ~ SX (400 V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

MR-C Servo SERVOMOTORS & AMPLIFIERS. Step Up to Servo Performance

MR-C Servo SERVOMOTORS & AMPLIFIERS. Step Up to Servo Performance MR-C Servo SERVOMOTORS & AMPLIFIERS Step Up to Servo Performance Small, Easy-to-Use, High- Performance. An Extraordinarily Compact, Intelligent Servo. The MR-C brushless servo, in a handy super-compact

More information

RDV-X/RDV-P Robot driver Only for pulse train control

RDV-X/RDV-P Robot driver Only for pulse train control Single axis Robot driver Only for pulse train control As the size is small and weight is light, it is easy to use in automated machinery. Features 1 Dedicated pulse train control The dedicated pulse train

More information

MR-J4-_A4(-RJ) MR-J4_B4(-RJ) SERVO AMPLIFIER INSTRUCTION MANUAL

MR-J4-_A4(-RJ) MR-J4_B4(-RJ) SERVO AMPLIFIER INSTRUCTION MANUAL General-Purpose AC Servo General-Purpose Interface/SSCNET /H Interface MODEL MR-J4-_A4(-RJ) MR-J4_B4(-RJ) SERVO AMPLIFIER INSTRUCTION MANUAL B Safety Instructions Please read the instructions carefully

More information